Sign in to use this feature.

Years

Between: -

Subjects

remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline

Journals

remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline

Article Types

Countries / Regions

remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline

Search Results (745)

Search Parameters:
Keywords = safe operational ranges

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
21 pages, 2799 KiB  
Article
Structural Integrity Assessments of an IMO Type C LCO2 Cargo Tank
by Joon Kim, Kyu-Sik Park, Inhwan Cha and Joonmo Choung
J. Mar. Sci. Eng. 2025, 13(8), 1479; https://doi.org/10.3390/jmse13081479 - 31 Jul 2025
Abstract
With the rise of carbon capture and storage, liquefied carbon dioxide (LCO2) has emerged as a promising medium for large-scale marine transport. This study evaluates the structural integrity of an IMO Type C cargo tank for a medium-range LCO2 carrier [...] Read more.
With the rise of carbon capture and storage, liquefied carbon dioxide (LCO2) has emerged as a promising medium for large-scale marine transport. This study evaluates the structural integrity of an IMO Type C cargo tank for a medium-range LCO2 carrier under four conditions: ultimate limit state, accidental limit state, hydrostatic pressure test, and fatigue limit state, based on IGC Code and classification rules. Seventeen load cases were analyzed using finite element methods with multi-step loading to ensure stability. The highest stress occurred at the pump dome–shell junction due to geometric discontinuities, but all stress and buckling criteria were satisfied. The fatigue damage from wave-induced loads was negligible, with low-cycle fatigue from loading/unloading operations governing the fatigue life, which exceeded 31,000 years. The findings confirm the tank’s structural robustness and its suitability for safe, efficient medium-pressure LCO2 transport. Full article
(This article belongs to the Special Issue New Advances in the Analysis and Design of Marine Structures)
Show Figures

Figure 1

32 pages, 5581 KiB  
Article
Composite Noise Reduction Method for Internal Leakage Acoustic Emission Signal of Safety Valve Based on IWTD-IVMD Algorithm
by Shuxun Li, Xiaoqi Meng, Jianjun Hou, Kang Yuan and Xiaoya Wen
Sensors 2025, 25(15), 4684; https://doi.org/10.3390/s25154684 - 29 Jul 2025
Viewed by 214
Abstract
As the core device for protecting the safety of the pressure-bearing system, the spring full-open safety valve is prone to various forms of valve seat sealing surface damage after long-term opening and closing impact, corrosion, and medium erosion, which may lead to internal [...] Read more.
As the core device for protecting the safety of the pressure-bearing system, the spring full-open safety valve is prone to various forms of valve seat sealing surface damage after long-term opening and closing impact, corrosion, and medium erosion, which may lead to internal leakage. In view of the problems that the high-frequency acoustic emission signal of the internal leakage of the safety valve has, namely, a large number of energy-overlapping areas in the frequency domain, the overall signal presents broadband characteristics, large noise content, and no obvious time–frequency characteristics. A composite denoising method, IWTD, improved wavelet threshold function with dual adjustable factors, and the improved VMD algorithm is proposed. In view of the problem that the optimal values of the dual adjustment factors a and b of the function are difficult to determine manually, an improved dung beetle optimization algorithm is proposed, with the maximum Pearson coefficient as the optimization target; the optimization is performed within the value range of the dual adjustable factors a and b, so as to obtain the optimal value. In view of the problem that the key parameters K and α in VMD decomposition are difficult to determine manually, the maximum Pearson coefficient is taken as the optimization target, and the improved dung beetle algorithm is used to optimize within the value range of K and α, so as to obtain the IVMD algorithm. Based on the IVMD algorithm, the characteristic decomposition of the internal leakage acoustic emission signal occurs after the denoising of the IWTD function is performed to further improve the denoising effect. The results show that the Pearson coefficients of all types of internal leakage acoustic emission signals after IWTD-IVMD composite noise reduction are greater than 0.9, which is much higher than traditional noise reduction methods such as soft and hard threshold functions. Therefore, the IWTD-IVMD composite noise reduction method can extract more main features out of the measured spring full-open safety valve internal leakage acoustic emission signals, and has a good noise reduction effect. Feature recognition after noise reduction can provide a good evaluation for the safe operation of the safety valve. Full article
(This article belongs to the Section Physical Sensors)
Show Figures

Figure 1

17 pages, 2000 KiB  
Article
Can 3D Exoscopy-Assisted Surgery Replace the Traditional Endoscopy in Septoplasty? Analysis of Our Two-Year Experience
by Luciano Catalfamo, Alessandro Calvo, Samuele Cicchiello, Antonino La Fauci, Francesco Saverio De Ponte, Calogero Scozzaro and Danilo De Rinaldis
J. Clin. Med. 2025, 14(15), 5279; https://doi.org/10.3390/jcm14155279 - 25 Jul 2025
Viewed by 291
Abstract
Background/Objectives: Septoplasty is a commonly performed surgical procedure aimed at correcting nasal septal deviations, to improve nasal airflow and respiratory function. Traditional approaches to septal correction rely on either direct visualization or endoscopic guidance. Recently, a novel technology known as exoscopy has [...] Read more.
Background/Objectives: Septoplasty is a commonly performed surgical procedure aimed at correcting nasal septal deviations, to improve nasal airflow and respiratory function. Traditional approaches to septal correction rely on either direct visualization or endoscopic guidance. Recently, a novel technology known as exoscopy has been introduced into surgical practice. Exoscopy is an “advanced magnification system” that provides an enlarged, three-dimensional view of the operating field. In this article, we present our experience with exoscope-assisted septoplasty, developed over the last two years, and compare it with our extensive experience using the endoscopic approach. Methods: Our case series includes 26 patients, predominantly males and young adults, who underwent exoscope-assisted septoplasty. We discuss the primary advantages of this technique and, most importantly, provide an analysis of its learning curve. The cohort of patients treated using the exoscopic approach was compared with a control group of 26 patients who underwent endoscope-guided septoplasty, randomly selected from our broader clinical database. Finally, we present a representative surgical case that details all phases of the exoscope-assisted procedure. Results: Our surgical experience has demonstrated that exoscopy is a safe and effective tool for performing septoplasty. Moreover, the learning curve associated with this technique exhibits a rapid and progressive improvement. Notably, exoscopy provides a substantial educational benefit for trainees and medical students, as it enables them to share the same visual perspective as the lead surgeon. Conclusions: Although further studies are required to validate this approach, we believe that exoscopy represents a promising advancement for a wide range of head and neck procedures, and certainly for septoplasty. Full article
(This article belongs to the Special Issue Recent Advances in Reconstructive Oral and Maxillofacial Surgery)
Show Figures

Figure 1

21 pages, 3722 KiB  
Article
State of Health Estimation for Lithium-Ion Batteries Based on TCN-RVM
by Yu Zhao, Yonghong Xu, Yidi Wei, Liang Tong, Yiyang Li, Minghui Gong, Hongguang Zhang, Baoying Peng and Yinlian Yan
Appl. Sci. 2025, 15(15), 8213; https://doi.org/10.3390/app15158213 - 23 Jul 2025
Viewed by 236
Abstract
A State of Health (SOH) estimation of lithium-ion batteries is a core function of battery management systems, directly affecting the safe operation, lifetime prediction, and economic efficiency of batteries. However, existing methods still face challenges in balancing feature robustness and model generalization ability; [...] Read more.
A State of Health (SOH) estimation of lithium-ion batteries is a core function of battery management systems, directly affecting the safe operation, lifetime prediction, and economic efficiency of batteries. However, existing methods still face challenges in balancing feature robustness and model generalization ability; for instance, some studies rely on features whose physical correlation with SOH lacks strict verification, or the models struggle to simultaneously capture the temporal dynamics of health factors and nonlinear mapping relationships. To address this, this paper proposes an SOH estimation method based on incremental capacity (IC) curves and a Temporal Convolutional Network—Relevance Vector Machine (TCN-RVM) model, with core innovations reflected in two aspects. Firstly, five health factors are extracted from IC curves, and the strong correlation between these features and SOH is verified using both Pearson and Spearman coefficients, ensuring the physical rationality and statistical significance of feature selection. Secondly, the TCN-RVM model is constructed to achieve complementary advantages. The dilated causal convolution of TCN is used to extract temporal local features of health factors, addressing the insufficient capture of long-range dependencies in traditional models; meanwhile, the Bayesian inference framework of RVM is integrated to enhance the nonlinear mapping capability and small-sample generalization, avoiding the overfitting tendency of complex models. Experimental validation is conducted using the lithium-ion battery dataset from the University of Maryland. The results show that the mean absolute error of the SOH estimation using the proposed method does not exceed 0.72%, which is significantly superior to comparative models such as CNN-GRU, KELM, and SVM, demonstrating higher accuracy and reliability compared with other models. Full article
Show Figures

Figure 1

17 pages, 4372 KiB  
Article
Research of 110 kV High-Voltage Measurement Method Based on Rydberg Atoms
by Yinglong Diao, Zhaoyang Qu, Nan Qu, Jie Cao, Xinkun Li, Xiaoyu Xu and Shuhang You
Electronics 2025, 14(15), 2932; https://doi.org/10.3390/electronics14152932 - 23 Jul 2025
Viewed by 189
Abstract
Accurate measurement of high voltages is required to guarantee the safe and stable operation of power systems. Modern power systems, which are mainly based on new energy sources, require high-voltage measurement instruments and equipment with characteristics such as high accuracy, wide frequency bandwidth, [...] Read more.
Accurate measurement of high voltages is required to guarantee the safe and stable operation of power systems. Modern power systems, which are mainly based on new energy sources, require high-voltage measurement instruments and equipment with characteristics such as high accuracy, wide frequency bandwidth, broad operating ranges, and ease of operation and maintenance. However, it is difficult for traditional electromagnetic measurement transformers to meet these requirements. To address the limitations of conventional Rydberg atomic measurement methods in low-frequency applications, this paper proposes an enhanced Rydberg measurement approach featuring high sensitivity and strong traceability, thereby enabling the application of Rydberg-based measurement methodologies under power frequency conditions. In this paper, a 110 kV high-voltage measurement method based on Rydberg atoms is studied. A power-frequency electric field measurement device is designed using Rydberg atoms, and its internal electric field distribution is analyzed. Additionally, a decoupling method is proposed to facilitate voltage measurements under multi-phase overhead lines in field conditions. The feasibility of the proposed method is confirmed, providing support for the future development of practical measurement devices. Full article
Show Figures

Figure 1

21 pages, 2547 KiB  
Article
Remaining Available Energy Prediction for Energy Storage Batteries Based on Interpretable Generalized Additive Neural Network
by Ji Qi, Pengrui Li, Yifan Dong, Zhicheng Fu, Zhanguo Wang, Yong Yi and Jie Tian
Batteries 2025, 11(7), 276; https://doi.org/10.3390/batteries11070276 - 20 Jul 2025
Viewed by 233
Abstract
Precise estimation of the remaining available energy in batteries is not only key to improving energy management efficiency, but also serves as a critical safeguard for ensuring the safe operation of battery systems. To address the challenges associated with energy state estimation under [...] Read more.
Precise estimation of the remaining available energy in batteries is not only key to improving energy management efficiency, but also serves as a critical safeguard for ensuring the safe operation of battery systems. To address the challenges associated with energy state estimation under dynamic operating conditions, this study proposes a method for predicting the remaining available energy of energy storage batteries based on an interpretable generalized additive neural network (IGANN). First, considering the variability in battery operating conditions, the study designs a battery working voltage threshold that accounts for safety margins and proposes an available energy state assessment metric, which enhances prediction consistency under different discharge conditions. Subsequently, 12 features are selected from both direct observation and statistical characteristics to capture the operating condition information of the battery, and a dataset is constructed using actual operational data from an energy storage station. Finally, the model is trained and validated on the feature dataset. The validation results show that the model achieves an average absolute error of 2.39%, indicating that it effectively captures the energy variation characteristics within the 0.2 C to 0.6 C dynamic current range. Furthermore, the contribution of each feature is analyzed based on the model’s interpretability, and the model is optimized by utilizing high-contribution features. This optimization improves both the accuracy and runtime efficiency of the model. Finally, a dynamic prediction is conducted for a discharge cycle, comparing the predictions of the IGANN model with those of three other machine learning methods. The IGANN model demonstrates the best performance, with the average absolute error consistently controlled within 3%, proving the model’s accuracy and robustness under complex conditions. Full article
(This article belongs to the Special Issue Advances in Lithium-Ion Battery Safety and Fire: 2nd Edition)
Show Figures

Figure 1

17 pages, 2829 KiB  
Article
Apparatus and Experiments Towards Fully Automated Medical Isotope Production Using an Ion Beam Accelerator
by Abdulaziz Yahya M. Hussain, Aliaksandr Baidak, Ananya Choudhury, Andy Smith, Carl Andrews, Eliza Wojcik, Liam Brown, Matthew Nancekievill, Samir De Moraes Shubeita, Tim A. D. Smith, Volkan Yasakci and Frederick Currell
Instruments 2025, 9(3), 18; https://doi.org/10.3390/instruments9030018 - 18 Jul 2025
Viewed by 225
Abstract
Zirconium-89 (89Zr) is a widely used radionuclide in immune-PET imaging due to its physical decay characteristics. Despite its importance, the production of 89Zr radiopharmaceuticals remains largely manual, with limited cost-effective automation solutions available. To address this, we developed an automated [...] Read more.
Zirconium-89 (89Zr) is a widely used radionuclide in immune-PET imaging due to its physical decay characteristics. Despite its importance, the production of 89Zr radiopharmaceuticals remains largely manual, with limited cost-effective automation solutions available. To address this, we developed an automated system for the agile and reliable production of radiopharmaceuticals. The system performs transmutations, dissolution, and separation for a range of radioisotopes. Steps in the production of 89Zr-oxalate are used as an exemplar to illustrate its use. Three-dimensional (3D) printing was exploited to design and manufacture a target holder able to include solid targets, in this case an 89Y foil. Spot welding was used to attach 89Y to a refractory tantalum (Ta) substrate. A commercially available CPU chiller was repurposed to efficiently cool the metal target. Furthermore, a commercial resin (ZR Resin) and compact peristaltic pumps were employed in a compact (10 × 10 × 10 cm3) chemical separation unit that operates automatically via computer-controlled software. Additionally, a standalone 3D-printed unit was designed with three automated functionalities: photolabelling, vortex mixing, and controlled heating. All components of the assembly, except for the target holder, are housed inside a commercially available hot cell, ensuring safe and efficient operation in a controlled environment. This paper details the design, construction, and modelling of the entire assembly, emphasising its innovative integration and operational efficiency for widespread radiopharmaceutical automation. Full article
Show Figures

Figure 1

18 pages, 3307 KiB  
Article
Temperature-Related Containment Analysis and Optimal Design of Aluminum Honeycomb Sandwich Aero-Engine Casings
by Shuyi Yang, Ningke Tong and Jianhua Zuo
Coatings 2025, 15(7), 834; https://doi.org/10.3390/coatings15070834 - 17 Jul 2025
Viewed by 268
Abstract
Aero-engine casings with excellent impact resistance are a practical requirement for ensuring the safe operation of aero-engines. In this paper, we report on numerical simulations of broken rotating blades impacting aluminum honeycomb sandwich casings under different temperatures and optimization of structural parameters. Firstly, [...] Read more.
Aero-engine casings with excellent impact resistance are a practical requirement for ensuring the safe operation of aero-engines. In this paper, we report on numerical simulations of broken rotating blades impacting aluminum honeycomb sandwich casings under different temperatures and optimization of structural parameters. Firstly, an impact test system with adjustable temperature was established. Restricted by the temperature range of the strain gauge, ballistic impact tests were carried out at 25 °C, 100 °C, and 200 °C. Secondly, a finite element (FE) model including a pointed bullet and an aluminum honeycomb sandwich plate was built using LS-DYNA. The corresponding simulations of the strain–time curve and damage conditions showed good agreement with the test results. Then, the containment capability of the aluminum honeycomb sandwich aero-engine casing at different temperatures was analyzed based on the kinetic energy loss of the blade, the internal energy increment of the casing, and the containment state of the blade. Finally, with the design objectives of minimizing the casing mass and maximizing the blade kinetic energy loss, the structural parameters of the casing were optimized using the multi-objective genetic algorithm (MOGA). Full article
Show Figures

Figure 1

24 pages, 1605 KiB  
Article
Quantum-Secure Coherent Optical Networking for Advanced Infrastructures in Industry 4.0
by Ofir Joseph and Itzhak Aviv
Information 2025, 16(7), 609; https://doi.org/10.3390/info16070609 - 15 Jul 2025
Viewed by 432
Abstract
Modern industrial ecosystems, particularly those embracing Industry 4.0, increasingly depend on coherent optical networks operating at 400 Gbps and beyond. These high-capacity infrastructures, coupled with advanced digital signal processing and phase-sensitive detection, enable real-time data exchange for automated manufacturing, robotics, and interconnected factory [...] Read more.
Modern industrial ecosystems, particularly those embracing Industry 4.0, increasingly depend on coherent optical networks operating at 400 Gbps and beyond. These high-capacity infrastructures, coupled with advanced digital signal processing and phase-sensitive detection, enable real-time data exchange for automated manufacturing, robotics, and interconnected factory systems. However, they introduce multilayer security challenges—ranging from hardware synchronization gaps to protocol overhead manipulation. Moreover, the rise of large-scale quantum computing intensifies these threats by potentially breaking classical key exchange protocols and enabling the future decryption of stored ciphertext. In this paper, we present a systematic vulnerability analysis of coherent optical networks that use OTU4 framing, Media Access Control Security (MACsec), and 400G ZR+ transceivers. Guided by established risk assessment methodologies, we uncover critical weaknesses affecting management plane interfaces (e.g., MDIO and I2C) and overhead fields (e.g., Trail Trace Identifier, Bit Interleaved Parity). To mitigate these risks while preserving the robust data throughput and low-latency demands of industrial automation, we propose a post-quantum security framework that merges spectral phase masking with multi-homodyne coherent detection, strengthened by quantum key distribution for key management. This layered approach maintains backward compatibility with existing infrastructure and ensures forward secrecy against quantum-enabled adversaries. The evaluation results show a substantial reduction in exposure to timing-based exploits, overhead field abuses, and cryptographic compromise. By integrating quantum-safe measures at the optical layer, our solution provides a future-proof roadmap for network operators, hardware vendors, and Industry 4.0 stakeholders tasked with safeguarding next-generation manufacturing and engineering processes. Full article
Show Figures

Figure 1

14 pages, 1679 KiB  
Article
Integrating 3D Printing with Injection Molding for Improved Manufacturing Efficiency
by Zdenek Chval, Karel Raz and João Pedro Amaro Bennett da Silva
Polymers 2025, 17(14), 1935; https://doi.org/10.3390/polym17141935 - 14 Jul 2025
Viewed by 434
Abstract
This study investigates a hybrid manufacturing approach that combines 3D printing and injection molding to extend the limitations of each individual technique. Injection molding is often limited by high initial tooling costs, long lead times, and restricted geometric flexibility, whereas 3D-printed molds tend [...] Read more.
This study investigates a hybrid manufacturing approach that combines 3D printing and injection molding to extend the limitations of each individual technique. Injection molding is often limited by high initial tooling costs, long lead times, and restricted geometric flexibility, whereas 3D-printed molds tend to suffer from material degradation, extended cooling times, and lower surface quality. By integrating 3D-printed molds into the injection-molding process, this hybrid method enables the production of complex geometries with improved cost-efficiency. The approach is demonstrated using a range of polymeric materials, including ABS, nylon, and polyurethane foam—each selected to enhance the mechanical and thermal performance of the final products. Finite element method (FEM) analysis was conducted to assess thermal distribution, deformation, and stress during manufacturing. Results indicated that both temperature and stress remained within safe operational limits for 3D-printed materials. An economic analysis revealed substantial cost savings compared to fully 3D-printed components, establishing hybrid manufacturing as a viable and scalable alternative. This method offers broad industrial applicability, delivering enhanced mechanical properties, design flexibility, and reduced production costs. Full article
(This article belongs to the Section Polymer Processing and Engineering)
Show Figures

Figure 1

6 pages, 352 KiB  
Article
A Single-Incision Method for the Removal of Vagus Nerve Stimulators: A Single-Institution Retrospective Review
by Michael Baumgartner, Matthew Diehl and James E. Baumgartner
Brain Sci. 2025, 15(7), 738; https://doi.org/10.3390/brainsci15070738 - 10 Jul 2025
Viewed by 324
Abstract
Vagal nerve stimulators (VNSs) improve seizure control in up to half of the patients who have them implanted. In non-responding patients, VNS removal may be necessary. Removal is traditionally accomplished through two incisions. We present our experience removing VNSs through a single incision. [...] Read more.
Vagal nerve stimulators (VNSs) improve seizure control in up to half of the patients who have them implanted. In non-responding patients, VNS removal may be necessary. Removal is traditionally accomplished through two incisions. We present our experience removing VNSs through a single incision. Background/Objectives: To determine if VNS removal can be safely performed through a single incision. Methods: The medical records of 73 consecutive patients who underwent VNS removal at our institution from 2012 to 2024 were reviewed. Patients were divided into single-incision and two-incision treatment groups. Operative time and surgical complications were compared between groups. Results: A total of 73 patients underwent VNS removal during the study timeframe. Forty-eight VNS removals were accomplished via a single incision, while 25 required both incisions. Time in the operating room was roughly half as long for single-incision removal vs. two-incision removal (29.4 min, range 11–84 vs. 74.2 min, range 33–203); however, single incision was initially attempted in all cases. In two of the incision cases, the neck dissection resulted in an injury to the internal jugular (IJ) vein. In one case, the IJ was repaired and the lead wire removed. In a second case, the IJ could not be repaired, and a segment of lead wire was retained. In a third case, a short length of lead wire was discovered after a single-incision removal and a second procedure was necessary for removal. There were no significant differences in the rates of transient vocal cord weakness, cough, and/or dysphagia between both treatment groups (p = 0.7368), and there were no cases of permanent nerve palsy. Conclusions: VNS removal can be safely accomplished via a single incision in most cases. Successful single-incision procedures may be shorter than the two-incision approach. Attempted VNS removal via a single incision may result in increased incidence of transient hoarseness, dysphagia, and/or cough, but may result in reduced rates of permanent injury or IJ injury. Full article
(This article belongs to the Section Neurosurgery and Neuroanatomy)
Show Figures

Figure 1

15 pages, 2397 KiB  
Article
A Double Closed-Loop Process for Nanoparticle Synthesis via Aerosol Mixing and Venturi Jet Scrubbing
by Bruno Fabiano, Marco Salerno, Marco Vocciante, Omar Soda and Andrea Pietro Reverberi
Appl. Sci. 2025, 15(14), 7693; https://doi.org/10.3390/app15147693 - 9 Jul 2025
Viewed by 260
Abstract
Inorganic nanoparticles (NPs) have been synthesised via mixing and coalescence of droplets containing precursors and entrained by gaseous streams. The droplets have been generated by ultrasonic aerosolisation of two different liquid phases, each containing the respective reagent. The as-produced NPs are trapped by [...] Read more.
Inorganic nanoparticles (NPs) have been synthesised via mixing and coalescence of droplets containing precursors and entrained by gaseous streams. The droplets have been generated by ultrasonic aerosolisation of two different liquid phases, each containing the respective reagent. The as-produced NPs are trapped by mixing with a liquid phase in a Venturi nozzle, acting simultaneously as a collector and concentrator of the solid nanosized phase produced. Commercial electrically powered ultrasonic aerosolising devices have been adapted to atomise salt solutions characterised by high electrical conductivity. This process allowed the synthesis of calcium carbonate NPs with an average diameter in the range of (34–52) nm, according to the concentration of precursors in the aerosolised phases. This closed-loop method of synthesis, where neither capping agents were used nor demanding operating conditions were adopted, can represent a safe and viable eco-friendly technique for NP production free of undesirable compounds, as required for pharmaceutical preparations and theranostic uses. Full article
Show Figures

Figure 1

16 pages, 5447 KiB  
Article
A Gate Driver for Crosstalk Suppression of eGaN HEMT Power Devices
by Longsheng Zhang, Kaihong Wang, Shilong Guo and Binxin Zhu
J. Low Power Electron. Appl. 2025, 15(3), 38; https://doi.org/10.3390/jlpea15030038 - 6 Jul 2025
Viewed by 246
Abstract
The eGaN HEMT power devices face serious crosstalk problems when applied to high-frequency bridge circuits, thereby limiting the switching performance of these devices. To address this issue, a gate driver is proposed in this paper that can suppress both positive and negative crosstalk [...] Read more.
The eGaN HEMT power devices face serious crosstalk problems when applied to high-frequency bridge circuits, thereby limiting the switching performance of these devices. To address this issue, a gate driver is proposed in this paper that can suppress both positive and negative crosstalk of eGaN HEMT power devices, offering the advantages of simple control and easy integration. The basic idea is to suppress positive crosstalk by constructing a negative voltage capacitor, and to suppress negative crosstalk by reducing the impedance of the gate loop. To verify the capability of the proposed gate driver, double-pulse and synchronous Buck test platforms are constructed. The experimental results clearly demonstrate that the proposed gate driver reduces the positive and negative crosstalk spikes by 2.03 V and 1.54 V, respectively, ensuring that the positive and negative crosstalk spikes fall within a safe operating range. Additionally, the turn-off speed of the device is enhanced, leading to a reduction in switching loss. Full article
Show Figures

Figure 1

16 pages, 1155 KiB  
Article
Measuring Viscosity and Consistency in Thickened Liquids for Dysphagia: Is There a Correlation Between Different Methods?
by Javier Marín-Sánchez, Sofía Gimeno-Ruiz, Alejandro Berzosa, Javier Raso and Cristina Sánchez-Gimeno
Foods 2025, 14(13), 2384; https://doi.org/10.3390/foods14132384 - 5 Jul 2025
Viewed by 389
Abstract
Dysphagia is a common clinical condition, especially among older adults, associated with an increased risk of malnutrition, aspiration, and respiratory complications. A key therapeutic approach involves modifying liquid consistency using thickening agents to achieve safer swallowing. Although rotational rheometry offers accurate viscosity characterization, [...] Read more.
Dysphagia is a common clinical condition, especially among older adults, associated with an increased risk of malnutrition, aspiration, and respiratory complications. A key therapeutic approach involves modifying liquid consistency using thickening agents to achieve safer swallowing. Although rotational rheometry offers accurate viscosity characterization, its complexity and cost limit routine application in clinical or domestic settings. This study evaluates and correlates different methods for measuring the viscosity of thickened liquids, comparing rheological data with empirical techniques such as the Ford cup, Bostwick consistometer, and Line-Spread Test (LST). Several thickeners were tested—guar gum, xanthan gum, a guar/xanthan blend, maltodextrin-based mixtures, and a commercial thickener—across a range of concentrations, temperatures, and preparation times. The results demonstrate that simple methods, particularly the Bostwick consistometer and LST, show strong correlations with rheometer measurements within the International Dysphagia Diet Standardisation Initiative (IDDSI) Level 2 (mildly thick) and Level 3 (moderately thick) ranges. However, limitations were observed at extreme viscosities, where certain methods lacked sensitivity or operational feasibility. These findings support the potential of empirical tools for practical viscosity screening in dysphagia management, especially where rheometry is unavailable. This work provides evidence-based guidance for clinicians, caregivers, and food service professionals seeking safe, reproducible, and standardized approaches to fluid consistency assessment. Full article
(This article belongs to the Section Food Analytical Methods)
Show Figures

Figure 1

20 pages, 4574 KiB  
Article
Experimental and Numerical Flow Assessment of the Main and Additional Tract of Prototype Differential Brake Valve
by Marcin Kisiel and Dariusz Szpica
Appl. Sci. 2025, 15(13), 7483; https://doi.org/10.3390/app15137483 - 3 Jul 2025
Viewed by 214
Abstract
The throughput of the pneumatic brake valve is a key parameter in ensuring fast and safe vehicle braking. The instantaneous value of this parameter determines the short response time of the system to an operator’s force. The scientific objective of this paper was [...] Read more.
The throughput of the pneumatic brake valve is a key parameter in ensuring fast and safe vehicle braking. The instantaneous value of this parameter determines the short response time of the system to an operator’s force. The scientific objective of this paper was to determine the throughput of brake valve tracts using numerical and experimental methods. These tracts are supposed to provide the tracking and acceleration function of the valve depending on the setting of the correction system. The first numerical method was based on polyhedral meshes using computational fluid dynamics (CFD) and Ansys Fluent software. The second research method—experimental tests on the author’s bench using the reservoir method—consisted of identifying throughputs based on pressure waveforms in the measurement tanks. The determined throughputs were averaged over the range of pressure differences tested and allowed the final calculation of the mass flow rate. The analysis of the obtained results showed an average discrepancy between the two research methods for both tracts, in which the flow in both directions was considered to be 9.43%, taking into account the use of a polyhedral numerical mesh ensuring high-quality results with an optimal simulation duration. The analysis of the pressure distribution inside the working chambers showed local areas of increased pressure and negative pressure resulting from the acceleration of the flow in narrow flow channels and the occurrence of the Venturi effect. Full article
(This article belongs to the Section Mechanical Engineering)
Show Figures

Figure 1

Back to TopTop