Sign in to use this feature.

Years

Between: -

Subjects

remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline

Journals

remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline

Article Types

Countries / Regions

remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline

Search Results (890)

Search Parameters:
Keywords = prosthetic implant

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
33 pages, 4268 KiB  
Review
Targeting Bacterial Biofilms on Medical Implants: Current and Emerging Approaches
by Alessandro Calogero Scalia and Ziba Najmi
Antibiotics 2025, 14(8), 802; https://doi.org/10.3390/antibiotics14080802 - 6 Aug 2025
Abstract
Biofilms are structured communities of microorganisms encased in a self-produced extracellular matrix, and they represent one of the most widespread forms of microbial life on Earth. Their presence poses serious challenges in both environmental and clinical settings. In natural and industrial systems, biofilms [...] Read more.
Biofilms are structured communities of microorganisms encased in a self-produced extracellular matrix, and they represent one of the most widespread forms of microbial life on Earth. Their presence poses serious challenges in both environmental and clinical settings. In natural and industrial systems, biofilms contribute to water contamination, pipeline corrosion, and biofouling. Clinically, biofilm-associated infections are responsible for approximately 80% of all microbial infections, including endocarditis, osteomyelitis, cystic fibrosis, and chronic sinusitis. A particularly critical concern is their colonization of medical devices, where biofilms can lead to chronic infections, implant failure, and increased mortality. Implantable devices, such as orthopedic implants, cardiac pacemakers, cochlear implants, urinary catheters, and hernia meshes, are highly susceptible to microbial attachment and biofilm development. These infections are often recalcitrant to conventional antibiotics and frequently necessitate surgical revision. In the United States, over 500,000 biofilm-related implant infections occur annually, with prosthetic joint infections alone projected to incur revision surgery costs exceeding USD 500 million per year—a figure expected to rise to USD 1.62 billion by 2030. To address these challenges, surface modification of medical devices has emerged as a promising strategy to prevent bacterial adhesion and biofilm formation. This review focuses on recent advances in chemical surface functionalization using non-antibiotic agents, such as enzymes, chelating agents, quorum sensing quenching factors, biosurfactants, oxidizing compounds and nanoparticles, designed to enhance antifouling and mature biofilm eradication properties. These approaches aim not only to prevent device-associated infections but also to reduce dependence on antibiotics and mitigate the development of antimicrobial resistance. Full article
(This article belongs to the Special Issue Antibacterial and Antibiofilm Properties of Biomaterial)
Show Figures

Graphical abstract

30 pages, 4515 KiB  
Article
Implant-Supported Oral Rehabilitation in Head and Neck Cancer Patients: A 20-Year Single-Center Study (2005–2024)
by Manuel Tousidonis, Santiago Ochandiano, Carlos Navarro-Cuellar, Carlos Navarro-Vila, Javier López de Atalaya, Cristina Maza, Ana María Lopez Lopez, Ignacio Navarro-Cuellar, Alba García Sevilla, Gema Arenas de Frutos, Raul Antunez-Conde, Paloma Planells del Pozo and Jose Ignacio Salmeron
J. Clin. Med. 2025, 14(15), 5435; https://doi.org/10.3390/jcm14155435 - 1 Aug 2025
Viewed by 276
Abstract
Background/Objectives: Oral cancer resection often leads to maxillofacial defects and dentition loss, compromising patients’ quality of life. Implant-supported prosthetic rehabilitation offers a reliable solution to restore function, though factors such as bone reconstruction, radiotherapy, and timing of implant placement (immediate vs. delayed) may [...] Read more.
Background/Objectives: Oral cancer resection often leads to maxillofacial defects and dentition loss, compromising patients’ quality of life. Implant-supported prosthetic rehabilitation offers a reliable solution to restore function, though factors such as bone reconstruction, radiotherapy, and timing of implant placement (immediate vs. delayed) may influence outcomes. This study aimed to evaluate long-term implant survival and rehabilitation timelines in oncologic patients, comparing two cohorts (2005–2014 and 2015–2024) to assess the impact of evolving clinical practices. Methods: A retrospective cohort study was conducted at Hospital General Universitario Gregorio Marañón (Madrid, Spain), including 304 patients who underwent ablative oral cancer surgery and subsequent implant-based rehabilitation between 2005 and 2024. Data on demographics, oncologic treatment, reconstruction, implant timing, and prosthetic rehabilitation were collected. Outcomes were compared using Kaplan–Meier analysis and appropriate statistical tests between the 2005–2014 (n = 122) and 2015–2024 (n = 182) cohorts. Results: A total of 2341 Ticare Implants® were placed, supporting 281 prostheses. Implant placement during primary surgery increased from 41% to 71% (p < 0.001). The median time from surgery to prosthesis significantly decreased from 24 to 15 months (p < 0.001). Five-year implant survival was 95% in the early cohort versus 97% in the later cohort. Implant survival was comparable between irradiated and non-irradiated patients (~94–96%). Fixed prostheses became more frequent (92% vs. 79%, p = 0.002). Conclusions: Implant-supported rehabilitation in oncologic patients is highly feasible and durable, with improved timelines and functional outcomes associated with early implant placement and modern digital planning strategies. Full article
(This article belongs to the Special Issue Research Progress in Osseointegrated Oral Implants)
Show Figures

Figure 1

12 pages, 2302 KiB  
Article
Edentulous Mandibles Restored with Fiber-Reinforced Composite Prostheses Supported by 5.0 mm Ultra-Short Implants: Ten-Year Follow-Up
by Giulia Petroni, Fabrizio Zaccheo, Cosimo Rupe and Andrea Cicconetti
Prosthesis 2025, 7(4), 94; https://doi.org/10.3390/prosthesis7040094 - 1 Aug 2025
Viewed by 337
Abstract
Background/Objectives: This study aimed to assess the long-term clinical performance of full-arch fixed restorations made of fiber-reinforced composite (FRC) supported by four ultra-short implants (4.0 × 5.0 mm) in patients with edentulous, atrophic mandibles. Methods: Ten patients were treated at Sapienza University of [...] Read more.
Background/Objectives: This study aimed to assess the long-term clinical performance of full-arch fixed restorations made of fiber-reinforced composite (FRC) supported by four ultra-short implants (4.0 × 5.0 mm) in patients with edentulous, atrophic mandibles. Methods: Ten patients were treated at Sapienza University of Rome and monitored over a 10-year period. Each case involved the placement of four plateau-design implants with a pure conometric connection and a calcium phosphate-treated surface. The final prostheses were fabricated using CAD/CAM-milled Trinia® fiber-reinforced composite frameworks. Clinical parameters included implant and prosthesis survival, marginal bone level (MBL), peri-implant probing depth (PPD), and patient-reported outcome measures (PROMs). Results: Implant and prosthesis survival reached 100% over the 10-year follow-up. MBL data showed a minor bone gain of approximately 0.11 mm per 5 years (p < 0.0001). PPD remained stable under 3 mm, with a minimal increase of 0.16 mm over the same period (p < 0.0001). PROMs reflected sustained high patient satisfaction. No technical complications, such as chipping or framework fracture, were observed. Conclusions: Rehabilitation of the edentulous mandible with ultra-short implants and metal-free FRC prostheses proved to be a minimally invasive and long-lasting treatment option. The 10-year follow-up confirmed excellent implant and prosthetic outcomes, favorable peri-implant tissue health, and strong patient satisfaction. Nonetheless, further studies with larger sample sizes are needed to confirm these encouraging results and strengthen the clinical evidence. Full article
Show Figures

Figure 1

18 pages, 8141 KiB  
Review
AI-Driven Aesthetic Rehabilitation in Edentulous Arches: Advancing Symmetry and Smile Design Through Medit SmartX and Scan Ladder
by Adam Brian Nulty
J. Aesthetic Med. 2025, 1(1), 4; https://doi.org/10.3390/jaestheticmed1010004 - 1 Aug 2025
Viewed by 600
Abstract
The integration of artificial intelligence (AI) and advanced digital workflows is revolutionising full-arch implant dentistry, particularly for geriatric patients with edentulous and atrophic arches, for whom achieving both prosthetic passivity and optimal aesthetic outcomes is critical. This narrative review evaluates current challenges in [...] Read more.
The integration of artificial intelligence (AI) and advanced digital workflows is revolutionising full-arch implant dentistry, particularly for geriatric patients with edentulous and atrophic arches, for whom achieving both prosthetic passivity and optimal aesthetic outcomes is critical. This narrative review evaluates current challenges in intraoral scanning accuracy—such as scan distortion, angular deviation, and cross-arch misalignment—and presents how innovations like the Medit SmartX AI-guided workflow and the Scan Ladder system can significantly enhance precision in implant position registration. These technologies mitigate stitching errors by using real-time scan body recognition and auxiliary geometric references, yielding mean RMS trueness values as low as 11–13 µm, comparable to dedicated photogrammetry systems. AI-driven prosthetic design further aligns implant-supported restorations with facial symmetry and smile aesthetics, prioritising predictable midline and occlusal plane control. Early clinical data indicate that such tools can reduce prosthetic misfits to under 20 µm and lower complication rates related to passive fit, while shortening scan times by up to 30% compared to conventional workflows. This is especially valuable for elderly individuals who may not tolerate multiple lengthy adjustments. Additionally, emerging AI applications in design automation, scan validation, and patient-specific workflow adaptation continue to evolve, supporting more efficient and personalised digital prosthodontics. In summary, AI-enhanced scanning and prosthetic workflows do not merely meet functional demands but also elevate aesthetic standards in complex full-arch rehabilitations. The synergy of AI and digital dentistry presents a transformative opportunity to consistently deliver superior precision, passivity, and facial harmony for edentulous implant patients. Full article
Show Figures

Graphical abstract

18 pages, 543 KiB  
Review
Individualized Selection of Valve Intervention Strategies in Aortic Disease Is Key for Better Outcomes
by Vasiliki Androutsopoulou, Prokopis-Andreas Zotos, Andrew Xanthopoulos, Evangelos Boultadakis, Dimitrios Magouliotis, Nikolaos Schizas, Dimitrios C. Iliopoulos, John Skoularigis and Thanos Athanasiou
J. Pers. Med. 2025, 15(8), 337; https://doi.org/10.3390/jpm15080337 - 1 Aug 2025
Viewed by 232
Abstract
Aortic valve diseases affect a significant percentage of the population, and with the extension of survival expectancy, they are expected to increase furthermore. Surgical treatment of aortic valve diseases mainly includes valve replacement and, rarely, its repair. The technology of both surgical and [...] Read more.
Aortic valve diseases affect a significant percentage of the population, and with the extension of survival expectancy, they are expected to increase furthermore. Surgical treatment of aortic valve diseases mainly includes valve replacement and, rarely, its repair. The technology of both surgical and transcatheter valves is evolving, and new prosthetic valves with improved characteristics are available, e.g., longer lifespan, faster implantation, better hemodynamic performance with better effective orifice area, suitable for small aortic annuli, etc. Minimally invasive surgical techniques are constantly evolving and spreading. New access sites are used for transcatheter valve implantation. The Heart Team determines the most appropriate intervention for each patient based on their anatomical and clinical profiles, aiming to optimize long-term outcomes. Full article
Show Figures

Figure 1

16 pages, 317 KiB  
Review
Combination Antibiotic Therapy for Orthopedic Infections
by Eric Bonnet and Julie Lourtet-Hascoët
Antibiotics 2025, 14(8), 761; https://doi.org/10.3390/antibiotics14080761 - 29 Jul 2025
Viewed by 302
Abstract
Background/Objectives: Limited robust data support the use of antibiotic combinations in the treatment of orthopedic infections. However, in certain situations, the combination of antibiotics seems to be beneficial. This review aims to outline the circumstances under which a combination of antibiotics may [...] Read more.
Background/Objectives: Limited robust data support the use of antibiotic combinations in the treatment of orthopedic infections. However, in certain situations, the combination of antibiotics seems to be beneficial. This review aims to outline the circumstances under which a combination of antibiotics may be utilized in the treatment of orthopedic infections. Methods: We reviewed the existing guidelines on orthopedic infections and focused on situations where antibiotic combinations are recommended or proposed optionally. We chose vitro and animal studies that provide evidence for the effectiveness of several widely recommended combinations. Results: The combinations serve multiple purposes: they provide empirical coverage while awaiting microbiological results, offer targeted treatment for difficult-to-treat infections, and facilitate oral treatment primarily for staphylococcal infections. The objectives include enhancing bacterial coverage against Gram-positive and Gram-negative bacteria, achieving synergistic effects with bactericidal agents, and reducing the risk of antibiotic resistance. The review outlines specific combinations for fracture-related infections, periprosthetic joint infections, spinal infections, and anterior cruciate ligament reconstruction infections, emphasizing the importance of tailoring antibiotic choices based on local epidemiology and patient history. The review also addresses potential drawbacks of combination therapy, such as toxicity, higher costs, and drug interactions, underscoring the complexity of managing orthopedic infections effectively. Conclusions: According to the guidelines, several different proposals are made, depending in part on the countries’ epidemiology. In a well-defined situation, various authors propose either monotherapy or a combination of antibiotics. When a combination is suggested, the choice of antibiotics is based on the expected effect: broadening the spectrum, enhancing bactericidal activity, achieving a synergistic effect, or reinforcing biofilm activity to optimize the treatment. Full article
(This article belongs to the Section Antibiotic Therapy in Infectious Diseases)
18 pages, 4344 KiB  
Review
Additive Manufacturing Technologies and Their Applications in Dentistry: A Systematic Literature Review
by Dragana Oros, Marko Penčić, Marko Orošnjak and Slawomir Kedziora
Appl. Sci. 2025, 15(15), 8346; https://doi.org/10.3390/app15158346 - 26 Jul 2025
Viewed by 388
Abstract
Additive manufacturing (AM) has emerged as a transformative technology in dentistry, enabling the production of patient-specific dental applications with reduced costs and fabrication times. Despite the growth of applications, a consolidated understanding of current 3D printing technologies, materials, and performance in dental settings [...] Read more.
Additive manufacturing (AM) has emerged as a transformative technology in dentistry, enabling the production of patient-specific dental applications with reduced costs and fabrication times. Despite the growth of applications, a consolidated understanding of current 3D printing technologies, materials, and performance in dental settings remains fragmented. Here, we perform a Systematic Literature Review (SLR) using the PRISMA protocol, retrieving 19 closely related primary studies. The evidence is synthesized across three axes: application domain, AM technology, and critical quality parameters. Dental restorations, prosthetics, crowns, and implants are the most common applications, while fused deposition modeling, stereolithography, digital light processing, selective laser sintering, and laser-directed energy deposition are the most used technologies. AM materials include polymers, metals, and emerging biomaterials. Key quality determinants include dimensional accuracy, wear and corrosion resistance, and photosensitivity. Notably, biocompatibility and cytotoxicity remain underexplored yet critical factors for ensuring long-term clinical safety. The evidence also suggests a lack of in vivo studies, insufficient tribological and microbiological testing, including limited data degradation pathways of AM materials under oral conditions. Understanding that there are disconnects between the realization of the clinical and the economic benefits of 3D printing in dentistry, future research requires standardized testing frameworks and long-term biocompatibility validation. Full article
Show Figures

Figure 1

19 pages, 967 KiB  
Article
Clinical–Biological Assessment of Prosthetic Field Following Pre-Prosthetic Phase Related to Prosthetic Treatment Solutions
by Petruţa Siminiuc, Doriana Agop-Forna, Cristina Dascălu and Norina Forna
Clin. Pract. 2025, 15(8), 140; https://doi.org/10.3390/clinpract15080140 - 26 Jul 2025
Viewed by 148
Abstract
Background. Extensive partial edentulism alters the biological and functional balance of the stomatognathic system, requiring targeted pre-prosthetic procedures to optimize treatment outcomes. Objectives. The aim of this study was to assess the extent of improvement in the clinical–biological scores of the [...] Read more.
Background. Extensive partial edentulism alters the biological and functional balance of the stomatognathic system, requiring targeted pre-prosthetic procedures to optimize treatment outcomes. Objectives. The aim of this study was to assess the extent of improvement in the clinical–biological scores of the prosthetic field in patients with extensive edentulism, following pre-prosthetic interventions. Materials and Method. This prospective, cross-sectional study investigated 194 subjects with extensive partial edentulism. Clinical–biological scores, initially and following the pre-prosthetic phase, were recorded using a scoring system that evaluated dental and periodontal status, bone and mucosal support, occlusion, and mandibulo-cranial relationships. Statistical comparisons of clinical–biological scores were related to the type of prosthetic therapy. Statistical significance was considered at a p-value < 0.05. Results. There was an overall significant improvement in the clinical–biological scores initially (mean value 20.2) and after pre-prosthetic procedures (mean value 23.22) (p < 0.001). When treatment groups were divided, the implant-assisted prosthesis group showed the best improvement in all domains, followed by the conventional fixed-prostheses group (p < 0.01). Dental support improved significantly in those with semi-rigid composite prostheses (p = 0.014), while periodontal support was improved in both fixed- and hybrid-implant groups. Mucosal and bone support improved mostly in the fixed-implant groups (p = 0.014). Conclusions. Pre-prosthetic procedures significantly enhance the biological and functional readiness of the prosthetic field, with the degree of improvement influenced by the complexity and type of planned prosthetic rehabilitation. The findings underscore the value of individualized pre-prosthetic protocols as an essential component of prosthetic treatment planning. Full article
Show Figures

Figure 1

19 pages, 3409 KiB  
Review
Indications and Complications of Subperiosteal Implants: Literature Review and Case Series
by Gerardo Pellegrino, Maryia Karaban, Carlo Barausse, Amerigo Giudice, Alessandro Antonelli, Roberto Pistilli and Pietro Felice
Dent. J. 2025, 13(8), 337; https://doi.org/10.3390/dj13080337 - 23 Jul 2025
Viewed by 338
Abstract
Background/Objectives: Severe jawbone atrophy, particularly in elderly or medically compromised patients, presents a significant challenge for conventional implant placement. In cases where bone augmentation is not feasible, alternative techniques—such as short, narrow, tilted, and zygomatic implants—may be indicated for the rehabilitation of the [...] Read more.
Background/Objectives: Severe jawbone atrophy, particularly in elderly or medically compromised patients, presents a significant challenge for conventional implant placement. In cases where bone augmentation is not feasible, alternative techniques—such as short, narrow, tilted, and zygomatic implants—may be indicated for the rehabilitation of the atrophic jaw. Subperiosteal implants have re-emerged as a further viable alternative, especially with recent advancements in digital planning and custom fabrication. This study aims to evaluate the clinical outcomes and complications associated with subperiosteal implants through a literature review and a supporting case series, and to propose clinical preliminary guidelines for their use. Methods: Fourteen studies—including case reports, case series, retrospective studies, and systematic reviews—were analyzed to assess the effectiveness and risk profile of subperiosteal implants. Additionally, we present a case series of nine patients with advanced vertical and horizontal alveolar bone atrophy treated using custom-made, digitally-designed subperiosteal implants. Surgical techniques, prosthetic workflows, and complications were recorded and assessed. Results: Subperiosteal implants were found to be particularly suitable for patients with narrow alveolar crests and severe atrophy where traditional implants are contraindicated. Literature and case series data indicated favorable outcomes, with early complications such as soft tissue inflammation and prosthetic misfit being manageable. A low complication rate was recorded in our series, with digital workflows contributing to improved implant fit and reduced technical errors. Conclusions: Subperiosteal implants could offer an effective solution for complex atrophic cases, provided that patient selection, surgical precision, and prosthetic design are meticulously managed. Based on our findings, clinical recommendations are proposed to guide their application in contemporary practice. Full article
(This article belongs to the Special Issue New Perspectives in Periodontology and Implant Dentistry)
Show Figures

Figure 1

20 pages, 3625 KiB  
Article
Improvement in the Corrosion and Wear Resistance of ZrO2-Ag Coatings on 316LVM Stainless Steel Under Tribocorrosive Conditions
by Willian Aperador and Giovany Orozco-Hernández
Coatings 2025, 15(8), 862; https://doi.org/10.3390/coatings15080862 - 22 Jul 2025
Viewed by 346
Abstract
This study investigates the development of silver (Ag)-doped zirconia (ZrO2) coatings deposited on 316LVM stainless steel via the unbalanced magnetron sputtering technique. The oxygen content in the Ar/O2 gas mixture was systematically varied (12.5%, 25%, 37.5%, and 50%) to assess [...] Read more.
This study investigates the development of silver (Ag)-doped zirconia (ZrO2) coatings deposited on 316LVM stainless steel via the unbalanced magnetron sputtering technique. The oxygen content in the Ar/O2 gas mixture was systematically varied (12.5%, 25%, 37.5%, and 50%) to assess its influence on the resulting coating properties. In response to the growing demand for biomedical implants with improved durability and biocompatibility, the objective was to develop coatings that enhance both wear and corrosion resistance in physiological environments. The effects of silver incorporation and oxygen concentration on the structural, tribological, and electrochemical behavior of the coatings were systematically analyzed. X-ray diffraction (XRD) was employed to identify crystalline phases, while atomic force microscopy (AFM) was used to characterize surface topography prior to wear testing. Wear resistance was evaluated using a ball-on-plane tribometer under simulated prosthetic motion, applying a 5 N load with a bone pin as the counter body. Corrosion resistance was assessed through electrochemical impedance spectroscopy (EIS) in a physiological solution. Additionally, tribocorrosive performance was investigated by coupling tribological and electrochemical tests in Ringer’s lactate solution, simulating dynamic in vivo contact conditions. The results demonstrate that Ag doping, combined with increased oxygen content in the sputtering atmosphere, significantly improves both wear and corrosion resistance. Notably, the ZrO2-Ag coating deposited with 50% O2 exhibited the lowest wear volume (0.086 mm3) and a minimum coefficient of friction (0.0043) under a 5 N load. This same coating also displayed superior electrochemical performance, with the highest charge transfer resistance (38.83 kΩ·cm2) and the lowest corrosion current density (3.32 × 10−8 A/cm2). These findings confirm the high structural integrity and outstanding tribocorrosive behavior of the coating, highlighting its potential for application in biomedical implant technology. Full article
Show Figures

Figure 1

12 pages, 6846 KiB  
Case Report
A Second Chance: Managing Late Implant Failure from Peri-Implantitis with Computer-Guided Bone Regeneration—A Clinical Case Report
by Marco Tallarico, Silvio Mario Meloni, Carlotta Cacciò, Francesco Mattia Ceruso and Aurea Immacolata Lumbau
Reports 2025, 8(3), 118; https://doi.org/10.3390/reports8030118 - 22 Jul 2025
Viewed by 345
Abstract
Background and Clinical Significance: The retreatment of failed dental implants remains a challenging clinical scenario, particularly when complicated by peri-implantitis and as sociated bone loss. Successful management requires a comprehensive and predictable approach that addresses both hard and soft tissue deficiencies. Case [...] Read more.
Background and Clinical Significance: The retreatment of failed dental implants remains a challenging clinical scenario, particularly when complicated by peri-implantitis and as sociated bone loss. Successful management requires a comprehensive and predictable approach that addresses both hard and soft tissue deficiencies. Case Presentation: This case report illustrates a fully digital, prosthetically driven workflow for the rehabilitation of a posterior mandibular site following implant failure. A 44-year-old female patient underwent removal of a failing implant and adjacent tooth due to advanced peri-implantitis and periodontitis. After healing, a digital workflow—including intraoral scanning, cone-beam computed tomography (CBCT), and virtual planning—was employed to design and fabricate a customized CAD/CAM titanium mesh for vertical guided bone regeneration. The grafting procedure utilized a composite mixture of autogenous bone and anorganic bovine bone (A-Oss). After nine months of healing, two implants with a hydrophilic surface (SOI) were placed using a fully guided surgical protocol (OneGuide system). Subsequent soft tissue grafting and final prosthetic rehabilitation with monolithic zirconia restorations resulted in stable functional and aesthetic outcomes. Conclusions: This case highlights how the integration of modern digital technologies with advanced regenerative procedures and innovative implant surfaces can enhance the predictability and long-term success of implant retreatment in compromised posterior sites. Full article
(This article belongs to the Section Dentistry/Oral Medicine)
Show Figures

Figure 1

12 pages, 2107 KiB  
Article
Assessment of Diameter Stability in Morse Taper Dental Implants with Different Angulations After Abutment Connection
by Bruno Q. S. Cordeiro, Waldimir R. Carvalho, Edgard M. Fonseca, Aldir N. Machado, Bruna Ghiraldini, Michel A. D. Soares and Priscila L. Casado
Materials 2025, 18(14), 3403; https://doi.org/10.3390/ma18143403 - 21 Jul 2025
Viewed by 302
Abstract
Background: Modification of diameter stability after the abutment retention can result in a decrease in the applied torque or affect the peri-implant tissue, compromising the longevity of the treatment. Therefore, this study aimed to investigate how different connection angles (11.5° and 16.0°) at [...] Read more.
Background: Modification of diameter stability after the abutment retention can result in a decrease in the applied torque or affect the peri-implant tissue, compromising the longevity of the treatment. Therefore, this study aimed to investigate how different connection angles (11.5° and 16.0°) at the implant–abutment interface influence implant diameter stability under the manufacturer’s recommended torque. Methods: Eighty Morse cone-type implant specimens were divided into two groups, with different internal conicity angles: 11.5° (n = 40) and 16.0° (n = 40). Implants varied in diameter (mm): 3.5, 3.8, 4.5, and 5.0. Initial measurements of the implants’ external diameter were carried out. After these measurements, all implants received the abutment installation, and a final measurement of the external implant diameter was performed. Results: Considering the comparative analysis between the final and initial diameters, a non-significant increase in diameter, in the cervical implant region, after torque on the abutment, was observed. The torque applied to the abutments did not produce deformations in the cervical area of Morse taper implants. Conclusions: The torque applied to the abutment screw in implants with a Morse taper connection does not cause deformation in the cervical area of the implant body in implant with 11.5° and 16.0° conicity angles. Full article
(This article belongs to the Section Biomaterials)
Show Figures

Figure 1

14 pages, 514 KiB  
Article
Mechanical and Biological Complications Two Years After Full-Arch Implant-Supported Prosthetic Rehabilitation: A Retrospective Clinical Study
by Denisa Tabita Sabău, Petra Saitos, Rahela Tabita Moca, Raluca Iulia Juncar and Mihai Juncar
Clin. Pract. 2025, 15(7), 134; https://doi.org/10.3390/clinpract15070134 - 18 Jul 2025
Viewed by 355
Abstract
Background/Objectives: Full-arch implant-supported prostheses have become a widely accepted solution for edentulous patients, yet long-term biological and mechanical complications remain a clinical concern. Methods: This retrospective study included 70 fully edentulous patients (362 implants) rehabilitated with either fixed or removable implant-supported prostheses. [...] Read more.
Background/Objectives: Full-arch implant-supported prostheses have become a widely accepted solution for edentulous patients, yet long-term biological and mechanical complications remain a clinical concern. Methods: This retrospective study included 70 fully edentulous patients (362 implants) rehabilitated with either fixed or removable implant-supported prostheses. Data were collected on demographics, medical status, type and location of prostheses, implant type, abutments, method of fixation, and complications. Statistical analysis included Fisher’s exact test, the Mann–Whitney U test, and chi-squared tests, with a significance level set at p < 0.05. Results: Mechanical complications occurred in 41.4% of patients (29 out of 70), with framework fractures reported in eight cases (27.6%), ceramic chipping in six cases (20.7%), and resin discoloration in four cases (13.8%). The prostheses were fabricated using monolithic zirconia, metal–ceramic crowns, zirconia on titanium bars, and hybrid resin/PMMA on cobalt–chromium frameworks. Gingival inflammation was also noted in 41.4% of cases (n = 29), predominantly in posterior implant regions. Younger patients and those without systemic diseases showed a significantly higher incidence of mechanical complications. Conclusions: Two years post-treatment, mechanical and biological complications appear to be independent phenomena, not significantly associated with most prosthetic variables. Patient-specific factors, particularly age and general health status, may have greater predictive value than prosthetic design. Limitations of the study include its retrospective design and the lack of radiographic data to assess peri-implant bone changes. Full article
Show Figures

Figure 1

16 pages, 6475 KiB  
Review
Fully Digital Workflow in Full-Arch Implant Rehabilitation: A Descriptive Methodological Review
by Chantal Auduc, Thomas Douillard, Emmanuel Nicolas and Nada El Osta
Prosthesis 2025, 7(4), 85; https://doi.org/10.3390/prosthesis7040085 - 16 Jul 2025
Viewed by 523
Abstract
Background. Digital dentistry continues to evolve, offering improved accuracy, efficiency, and patient experience across various prosthodontic procedures. Many previous reviews have focused on digital applications in prosthodontics. But the use of a fully digital workflow for full-arch implant-supported prostheses in edentulous patients remains [...] Read more.
Background. Digital dentistry continues to evolve, offering improved accuracy, efficiency, and patient experience across various prosthodontic procedures. Many previous reviews have focused on digital applications in prosthodontics. But the use of a fully digital workflow for full-arch implant-supported prostheses in edentulous patients remains an emerging and underexplored area in the literature. Objective. This article presents a comprehensive methodological review of the digital workflow in full-arch implant-supported rehabilitation. It follows a structured literature exploration and synthesizes relevant technological processes from patient assessment to prosthetic delivery. Methods. The relevant literature was retrieved from the PubMed database on 20 June 2024, to identify the most recent and relevant studies. A total of 22 articles met the eligibility criteria and were included in the review. The majority included case and technical reports. Results. The review illustrates the integration and application of digital tools in implant dentistry, including cone-beam computed tomography (CBCT) exposure, intraoral scanning, digital smile design, virtual patients, guided surgery, and digital scanning. The key findings demonstrate multiple advantages of a fully digital workflow, such as reduced treatment time and cost, increased patient satisfaction, and improved interdisciplinary communication. Conclusions. Despite these benefits, limitations persist due to the low level of evidence, technological challenges, and the lack of standardized protocols. Further randomized controlled trials and long-term clinical evaluations are essential to validate the effectiveness and feasibility of a fully digital workflow for full-arch implant-supported rehabilitation. Full article
Show Figures

Figure 1

14 pages, 1657 KiB  
Article
Assessment of Maximum Torque in Implant-Supported Prostheses: A Pilot Laboratory Study
by Mahoor Kaffashian, Seyedfarzad Fazaeli, Joana Fialho, Filipe Araújo, Patrícia Fonseca and André Correia
Prosthesis 2025, 7(4), 83; https://doi.org/10.3390/prosthesis7040083 - 15 Jul 2025
Viewed by 273
Abstract
Background/Objectives: the precise application of torque during prosthetic screw tightening is essential to the long-term success and mechanical stability of implant-supported restorations. This study aimed to evaluate the influence of practitioner experience, glove material, screwdriver length, and hand moisture on the maximum torque [...] Read more.
Background/Objectives: the precise application of torque during prosthetic screw tightening is essential to the long-term success and mechanical stability of implant-supported restorations. This study aimed to evaluate the influence of practitioner experience, glove material, screwdriver length, and hand moisture on the maximum torque value (MTV) generated during manual tightening. Methods: thirty participants, comprising 10 experienced professors and 20 senior dental students, performed tightening tasks under six hand conditions (nitrile gloves, latex gloves, and bare hands, each in dry and wet environments) using two screwdriver lengths (21 mm and 27 mm). The torque values were measured using a calibrated digital torque meter, and the results were analyzed using a linear mixed model. Results: professors applied significantly higher torque than students (16.92 Ncm vs. 15.03 Ncm; p = 0.008). Nitrile gloves yielded the highest torque (17.11 Ncm), surpassing bare hands significantly (p = 0.003). No statistically significant differences were found for screwdriver length (p = 0.12) or hand moisture (p = 0.11). Conclusions: these findings underscore the importance of clinical proficiency and glove material in torque delivery, providing evidence-based insights to enhance procedural reliability and training standards in implant prosthodontics. Full article
(This article belongs to the Section Prosthodontics)
Show Figures

Figure 1

Back to TopTop