Sign in to use this feature.

Years

Between: -

Subjects

remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline

Journals

Article Types

Countries / Regions

Search Results (17)

Search Parameters:
Keywords = immunomagnetic bead capture

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
22 pages, 1144 KB  
Article
Advancing Liquid Biopsy: First Clinical Demonstration of Bio-Ferrography for Isolation and Microscopic Characterization of EGFR-Positive Circulating Tumor Cells in Metastatic Cancer
by Ofer Levi, Alexander Shtabsky, Baruch Tal, Assaf Shapira, Shiran Shapira, Itai Benhar, Nadir Arber and Noam Eliaz
Cancers 2026, 18(14), 2262; https://doi.org/10.3390/cancers18142262 - 15 Jul 2026
Viewed by 438
Abstract
Background: Colorectal cancer (CRC), a leading cause of cancer-related mortality worldwide, necessitates improved non-invasive diagnostic and monitoring tools. Circulating tumor cells (CTCs), as intact cellular biomarkers in liquid biopsies, offer valuable morphological and genetic information and hold significant clinical potential for early [...] Read more.
Background: Colorectal cancer (CRC), a leading cause of cancer-related mortality worldwide, necessitates improved non-invasive diagnostic and monitoring tools. Circulating tumor cells (CTCs), as intact cellular biomarkers in liquid biopsies, offer valuable morphological and genetic information and hold significant clinical potential for early detection, prognosis, therapy monitoring, and drug development. Bio-ferrography is a non-invasive immunomagnetic separation technique that isolates magnetically labeled entities from fluid samples onto a glass substrate via a focused external magnetic field. Methods: This study employs, for the first time, bio-ferrography for isolation, counting, and microscopic characterization of circulating tumor cells (CTCs) expressing the human epidermal growth factor receptor (EGFR) from blood biopsies taken from patients in the hospital. Magnetic beads conjugated with anti-EGFR antibodies were used to selectively capture CTCs from peripheral blood samples of patients with metastatic CRC and other epithelial malignancies. The method enabled both enumeration and microscopic characterization of isolated cells. Results: Preliminary clinical results demonstrate that bio-ferrography achieves a sensitivity of 90% in stage-IV patients and exhibits higher true positive detection rates compared to conventional tumor biomarkers, including carbohydrate antigen 19-9 (CA 19-9) and carcinoembryonic antigen (CEA). Conclusions: These findings highlight the potential of bio-ferrography as a robust platform for CTC isolation and analysis. Full article
(This article belongs to the Special Issue Recent Advances in Liquid Biopsy Biomarkers of Cancer)
Show Figures

Figure 1

24 pages, 3623 KB  
Article
Automated Intracellular Immunofluorescence Staining Enabled by Magnetic 3D Mixing in a Modular Microfluidic Platform
by Zhengyi Zhang, Mengyu Wang, Runtao Zhong, Yingbo Zhao and Yeqing Sun
Biosensors 2026, 16(2), 120; https://doi.org/10.3390/bios16020120 - 13 Feb 2026
Viewed by 907
Abstract
Traditional sample preparation for flow cytometry is often labor-intensive, operator-dependent, and reagent-consuming, limiting its suitability for automated and point-of-care biosensing applications. To address these challenges, this study presents a functional modular microfluidic system integrating immunomagnetic beads (IMBs) to enable automated intracellular immunofluorescence (IF) [...] Read more.
Traditional sample preparation for flow cytometry is often labor-intensive, operator-dependent, and reagent-consuming, limiting its suitability for automated and point-of-care biosensing applications. To address these challenges, this study presents a functional modular microfluidic system integrating immunomagnetic beads (IMBs) to enable automated intracellular immunofluorescence (IF) staining. The modular microfluidic platform is enabled by a dynamically actuated three-dimensional magnetic field that couples with IMBs within a microfluidic reaction chamber, requiring only one-dimensional magnet translation to induce effective three-dimensional bead motion. This magnetic–chip cooperative strategy significantly enhances microscale mixing and cell capture, facilitating automated immunostaining of the radiation biomarker in CD4+ cells. Finite element simulations were employed to guide magnetic field design by analyzing magnetic force distributions and identifying key parameters, including magnet material, size, spatial arrangement, and chip–magnet distance. Experimental validation using CD4+ cell capture confirmed the effectiveness of the magnetic mixing strategy, revealing ∇B·B as the critical design parameter. An N52 NdFeB magnet (6 mm diameter, 10 mm height) positioned within 2.2 mm of the chamber centerline stably retained IMBs at flow rates below 200 µL/min. Under optimized conditions (magnet translation speed of 8 mm/s and a 15 min mixing duration), a maximum cell capture efficiency of 86% was achieved. Subsequent automated γH2AX IF staining demonstrated a strong linear dose–response relationship (R2 > 0.9) in mean fluorescence intensity. This study demonstrates a robust and scalable strategy for automating complex IF staining workflows, highlighting the potential of magnetic-field-assisted microfluidic platforms for biosensing applications requiring reliable intracellular biomarker detection. Full article
(This article belongs to the Section Environmental, Agricultural, and Food Biosensors)
Show Figures

Figure 1

19 pages, 3767 KB  
Article
MagSculptor: A Microfluidic Platform for High-Resolution Magnetic Fractionation of Low-Expression Cell Subtypes
by Zhenwei Liang, Yujiao Wang, Xuanhe Zhang, Yiqing Chen, Guoxu Yu, Xiaolei Guo, Yuan Ma and Jiadao Wang
Biosensors 2026, 16(1), 41; https://doi.org/10.3390/bios16010041 - 4 Jan 2026
Cited by 3 | Viewed by 1208
Abstract
Heterogeneous expression of a single surface protein within one cell population can drive major functional differences, yet low-expression subtypes remain difficult to isolate. Conventional tube-based immunomagnetic separation collapses all labelled cells into one positive fraction and thus cannot resolve small differences in marker [...] Read more.
Heterogeneous expression of a single surface protein within one cell population can drive major functional differences, yet low-expression subtypes remain difficult to isolate. Conventional tube-based immunomagnetic separation collapses all labelled cells into one positive fraction and thus cannot resolve small differences in marker abundance. Here, we present MagSculptor, a microfluidic platform for high-resolution magnetic fractionation of low-expression EpCAM-defined subtypes within one immunomagnetically labelled population at a time. Arrays of soft-magnetic strips create localized high-gradient zones that map modest differences in bead loading onto distinct capture positions, yielding High (H), Medium (M), Low (L), and Negative (N) fractions. Finite element method simulations of coupled magnetic and hydrodynamic fields quantify the field gradients and define an operating window. Experimentally, epithelial cancer cell lines processed sequentially under identical settings show reproducible subtype partitioning. In a low-EpCAM model (MDA-MB-231), conventional flow cytometry, under standard EpCAM staining conditions, did not yield a robust EpCAM-positive gate, whereas MagSculptor still revealed graded subpopulations. Western blotting confirms a monotonic decrease in EpCAM abundance from H to N, and doxorubicin assays show distinct in vitro drug sensitivities, while viability remains above 95%. MagSculptor thus helps extend immunomagnetic separation from binary enrichment to multi-level isolation of low-expression subtypes and provides a convenient front-end for downstream functional and molecular analyses. Full article
Show Figures

Figure 1

19 pages, 19265 KB  
Article
A Novel Microfluidic Platform for Circulating Tumor Cell Identification in Non-Small-Cell Lung Cancer
by Tingting Tian, Shanni Ma, Yan Wang, He Yin, Tiantian Dang, Guangqi Li, Jiaming Li, Weijie Feng, Mei Tian, Jinbo Ma and Zhijun Zhao
Micromachines 2025, 16(10), 1136; https://doi.org/10.3390/mi16101136 - 1 Oct 2025
Cited by 1 | Viewed by 1609
Abstract
Circulating tumor cells (CTCs) are crucial biomarkers for lung cancer metastasis and recurrence, garnering significant clinical attention. Despite this, efficient and cost-effective detection methods remain scarce. Consequently, there is an urgent demand for the development of highly sensitive CTC detection technologies to enhance [...] Read more.
Circulating tumor cells (CTCs) are crucial biomarkers for lung cancer metastasis and recurrence, garnering significant clinical attention. Despite this, efficient and cost-effective detection methods remain scarce. Consequently, there is an urgent demand for the development of highly sensitive CTC detection technologies to enhance lung cancer diagnosis and treatment. This study utilized microspheres and A549 cells to model CTCs, assessing the impact of acoustic field forces on cell viability and proliferation and confirming capture efficiency. Subsequently, CTCs from the peripheral blood of patients with lung cancer were captured and identified using fluorescence in situ hybridization, and the results were compared to the immunomagnetic bead method to evaluate the differences between the techniques. Finally, epidermal growth factor receptor (EGFR) mutation analysis was conducted on CTC-positive samples. The findings showed that acoustic microfluidic technology effectively captures microspheres, A549 cells, and CTCs without compromising cell viability or proliferation. Moreover, EGFR mutation analysis successfully identified mutation types in four samples, establishing a basis for personalized targeted therapy. In conclusion, acoustic microfluidic technology preserves cell viability while efficiently capturing CTCs. When integrated with EGFR mutation analysis, it provides robust support for the precise diagnosis and treatment of lung cancer as well as personalized drug therapy. Full article
(This article belongs to the Special Issue Application of Microfluidic Technology in Bioengineering)
Show Figures

Figure 1

20 pages, 3506 KB  
Article
AuNP/Magnetic Bead-Enhanced Electrochemical Sensor Toward Dual Saliva Alzheimer’s Biomarkers Detection
by Pengcheng Zhao, Jieyu Wang, Hongju Mao, Lin Zhou, Zhenhua Wu, Yunxing Lu, Teng Sun, Jianan Hui and Guowu Ma
Sensors 2025, 25(13), 4088; https://doi.org/10.3390/s25134088 - 30 Jun 2025
Cited by 8 | Viewed by 4995
Abstract
Alzheimer’s disease (AD) early screening requires non-invasive, high-sensitivity detection of low-abundance biomarkers in complex biofluids like saliva. In this study, we present a miniaturized, silicon-based electrochemical sensor for sequential detection of two AD salivary biomarkers, lactoferrin (Lf) and amyloid β-protein 1-42 (Aβ1-42 [...] Read more.
Alzheimer’s disease (AD) early screening requires non-invasive, high-sensitivity detection of low-abundance biomarkers in complex biofluids like saliva. In this study, we present a miniaturized, silicon-based electrochemical sensor for sequential detection of two AD salivary biomarkers, lactoferrin (Lf) and amyloid β-protein 1-42 (Aβ1-42), on a single reusable electrode. The sensor features a three-electrode system fabricated by sputter-coating a quartz substrate with gold (Au) sensing electrodes, which are further modified with gold nanoparticles (AuNPs) to form 3D dendritic structures that enhance surface area and electron transfer. To improve specificity, immunomagnetic beads (MBs) are employed to selectively capture and isolate target biomarkers from saliva samples. These MB–biomarker complexes are introduced into a polydimethylsiloxane chamber aligned with Au sensing electrodes, where a detachable magnet localizes the complexes onto the electrode surface to amplify redox signals. The AuNPs/MBs sensor achieves detection limits of 2 μg/mL for Lf and 0.1 pg/mL for Aβ1-42, outperforming commercial ELISA kits (37.5 pg/mL for Aβ1-42) and covering physiological salivary concentrations. After the MBs capture the biomarkers, the sensor can output the result within one minute. Cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS) measurements confirm enhanced electron transfer kinetics on AuNP-decorated surfaces, while linear correlations (R2 > 0.95) validate quantitative accuracy across biomarker ranges. The compact and integrated design eliminates reliance on bulky instrumentation and enables user-friendly operation, establishing a promising platform for portable, cost-effective AD screening and monitoring. Full article
(This article belongs to the Section Biomedical Sensors)
Show Figures

Figure 1

15 pages, 2312 KB  
Article
Microfluidic Integration of Magnetically Functionalized Microwires for Flow Cytometry Protein Quantification
by Liviu Clime, Catalin Pavel, Lidija Malic, Christina Nassif, Matthias Geissler, Nicoleta Lupu, Tibor-Adrian Óvári, Lucas Poncelet, Gaétan Veilleux, Elham Moslemi, Javier Alejandro Hernández-Castro, Daniel Sinnett, Diping Che and Teodor Veres
Materials 2025, 18(2), 215; https://doi.org/10.3390/ma18020215 - 7 Jan 2025
Cited by 1 | Viewed by 2629
Abstract
A novel approach to protein quantification utilizing a microfluidic platform activated by a magnetic assembly of functionalized magnetic beads around soft magnetic capture centers is presented. Functionalized magnetic beads, known for their high surface area and facile manipulation under external magnetic fields, are [...] Read more.
A novel approach to protein quantification utilizing a microfluidic platform activated by a magnetic assembly of functionalized magnetic beads around soft magnetic capture centers is presented. Functionalized magnetic beads, known for their high surface area and facile manipulation under external magnetic fields, are injected inside microfluidic channels and immobilized magnetically on the surface of glass-coated soft magnetic microwires placed along the symmetry axis of these channels. A fluorescent (Cy5) immunomagnetic sandwich ELISA is then performed by sequentially flowing the sample and all necessary reagents in the microfluidic channels. Direct protein quantification is performed by magnetically releasing the beads from the microwire and evaluating their fluorescence intensity with the help of a miniature (microfluidic-based) flow cytometer. Measurements of ICAM-1 protein concentration in human blood plasma samples confirm the feasibility of the approach through extensive performance benchmarking. The automation and multiplexing capabilities of the proposed platform further demonstrate its potential for protein quantification in point-of-care settings using microfluidics and miniature flow cytometry instruments. Full article
(This article belongs to the Section Advanced Nanomaterials and Nanotechnology)
Show Figures

Graphical abstract

10 pages, 417 KB  
Article
Isolation of Shiga Toxin-Producing Escherichia coli O157 and Non-O157 from Retail Imported Frozen Beef Marketed in Saudi Arabia Using Immunomagnetic Separation and Multiplex PCR
by Ahlam Almulhim, Amer Alomar, Ibrahim Alhabib, Lamya Zohair Yamani and Nasreldin Elhadi
Germs 2024, 14(4), 352-361; https://doi.org/10.18683/germs.2024.1445 - 31 Dec 2024
Cited by 4 | Viewed by 883
Abstract
Introduction: Shiga toxin-producing Escherichia coli (STEC), particularly E. coli O157:H7, is a major contributor to foodborne outbreaks globally. Both E. coli O157 and non-O157 strains can lead to severe health issues, including hemolytic colitis and hemolytic uremic syndrome, which can result in kidney [...] Read more.
Introduction: Shiga toxin-producing Escherichia coli (STEC), particularly E. coli O157:H7, is a major contributor to foodborne outbreaks globally. Both E. coli O157 and non-O157 strains can lead to severe health issues, including hemolytic colitis and hemolytic uremic syndrome, which can result in kidney failure. Methods: Two hundred and one frozen beef samples were purchased from various supermarkets located in the Eastern Province of Saudi Arabia and subsequently enriched in tryptic soy broth (TSB). From the enriched samples in TSB, 1 mL portion was mixed with immunomagnetic beads (IMB) coated with specific antibodies targeting the E. coli O157 O antigen. The beads, which contained the captured bacteria, were then streaked onto CHROMagar O157 and Sorbitol MacConkey (SMAC) agar. The DNA extracted from these samples was examined using multiplex PCR to identify potential virulence gene markers, specifically stx-1, stx-2, and eae. Results: Of the 201 examined samples, 88 (43.8%) and 106 (52.7%) were positive for E. coli and produced colorless and mauve colonies on SMAC agar and CHROMagar O157, respectively. Out of 298 isolates in total, 174 isolates of E. coli were isolated with IMB enrichment. The highest detection rate of virulence gene markers was found among isolates that had been isolated using IMB enrichment, where 25 (8.4%), 2 (0.7%) and 12 (4%) isolates tested positive for stx1, stx2, and eae genes respectively. Among 42 isolates harboring potential virulence gene markers, 11 isolates were identified as E. coli O157 (stx1+/eae+ or stx2+/eae+). ERIC-PCR genotyping was able to determine the genetic relatedness among 42 isolates of E. coli O157 and E. coli non-O157 into 10 types with four identical related clusters and a genetic similarity rate above 90% homology from the identified isolates. Conclusions: The present study gives a clear perspective on STEC contamination in imported frozen beef marketed in Saudi Arabia. Because of the many possibilities of STEC contamination in imported frozen beef, further studies on the spread of STEC at various levels of imported frozen meat are needed on a long-term basis. Full article
Show Figures

Figure 1

12 pages, 1611 KB  
Article
A Self-Assembled G-Quadruplex/Hemin DNAzyme-Driven DNA Walker Strategy for Sensitive and Rapid Detection of Lead Ions Based on Rolling Circle Amplification
by Yuhan Wang, Jiaxuan Xiao, Xiaona Lin, Amira Waheed, Ayyanu Ravikumar, Zhen Zhang, Yanmin Zou and Chengshui Chen
Biosensors 2023, 13(8), 761; https://doi.org/10.3390/bios13080761 - 26 Jul 2023
Cited by 14 | Viewed by 4441
Abstract
Herein, a sensitive biosensor is constructed based on a novel rolling circle amplification (RCA) for colorimetric quantification of lead ion (Pb2+). At the detection system, GR5 DNAzymes are modified on the surface of an immunomagnetic bead, and Pb2+ is captured [...] Read more.
Herein, a sensitive biosensor is constructed based on a novel rolling circle amplification (RCA) for colorimetric quantification of lead ion (Pb2+). At the detection system, GR5 DNAzymes are modified on the surface of an immunomagnetic bead, and Pb2+ is captured by the aptamer, inducing the disintegration of the GR5 DNAzyme and the release of the DNA walker. After the introduction of the template DNA, T4 DNA ligase, and phi29 DNA polymerase, an RCA is initiated for the sensitivity improvement of this method. Moreover, a G4-hemin DNAzyme is formed as a colorimetric signal, owing to its peroxide-like activity to catalyze the TMB-H2O2 substrate. Under the optimized conditions, the limit of detection (LOD) of this fabricated biosensor could reach 3.3 pM for Pb2+ with a concentration in the range of 0.01–1000 nM. Furthermore, the results of real samples analysis demonstrate its satisfactory accuracy, implying its great potential in the rapid detection of heavy metals in the environment. Full article
(This article belongs to the Special Issue DNA Biosensors for Highly Sensitive Detection)
Show Figures

Figure 1

12 pages, 1594 KB  
Article
pH-Regulated Strategy and Mechanism of Antibody Orientation on Magnetic Beads for Improving Capture Performance of Staphylococcus Species
by Fuying Kang, Yin Yang, Jingwen Li, Erning Chen, Tian Hong, Lulu Zhao and Meihong Du
Foods 2022, 11(22), 3599; https://doi.org/10.3390/foods11223599 - 11 Nov 2022
Cited by 11 | Viewed by 5164
Abstract
Immunomagnetic beads (IMBs) have been widely used to capture and isolate target pathogens from complex food samples. The orientation of the antibody immobilized on the surface of magnetic beads (MBs) is closely related to the effective recognition with an antigen. We put forward [...] Read more.
Immunomagnetic beads (IMBs) have been widely used to capture and isolate target pathogens from complex food samples. The orientation of the antibody immobilized on the surface of magnetic beads (MBs) is closely related to the effective recognition with an antigen. We put forward an available strategy to orient the antibody on the surface of MBs by changing the charged amino group ratio of the reactive amino groups at optimal pH value. Quantum dots labeling antigen assay, antigen-binding fragment (Fab) accessibility assay and lysine mimicking were used for the first time to skillfully illustrate the antibody orientation mechanism. This revealed that the positively charged ε-NH2 group of lysine on the Fc relative to the uncharged amino terminus on Fab was preferentially adsorbed on the surface of MBs with a negatively charged group at pH 8.0, resulting in antigen binding sites of antibody fully exposed. This study contributes to the understanding of the antibody orientation on the surface of MBs and the potential application of IMBs in the separation and detection of pathogenic bacteria in food samples. Full article
(This article belongs to the Special Issue Application of Immunoassay Technology in Food Inspection)
Show Figures

Figure 1

20 pages, 5870 KB  
Article
Direct, Rapid Detection of Pathogens from Urine Samples
by Sorin David, Raluca-Elena Munteanu, Ana-Maria Tițoiu, Ionela-Cristina Petcu, Ioana-Cristina Cernat, Corina Leancu, Mihaela Gheorghiu and Eugen Gheorghiu
Materials 2022, 15(21), 7640; https://doi.org/10.3390/ma15217640 - 31 Oct 2022
Cited by 7 | Viewed by 4916
Abstract
The problem of rapidly detecting pathogens directly from clinical samples poses significant analytical challenges. Addressing this issue in relation to urinary tract infections, we propose an effective protocol and related immunomagnetic test kits enabling versatile screening for the presence of pathogenic bacteria in [...] Read more.
The problem of rapidly detecting pathogens directly from clinical samples poses significant analytical challenges. Addressing this issue in relation to urinary tract infections, we propose an effective protocol and related immunomagnetic test kits enabling versatile screening for the presence of pathogenic bacteria in unprocessed urine samples. To achieve this, the components of a typical immunomagnetic separation protocol were optimized towards the sensitive assessment of the aggregates formed out of immunomagnetically tagged target pathogens collected from clinical samples. Specifically, a dedicated immunomagnetic material was developed via the functionalization of standardized, micron-sized magnetic beads with generic antibodies against gram-specific bacterial constituents with mannan binding lectin. As such, we demonstrate efficient procedures for achieving the enhanced, specific, and pathogen-mediated cluster formation of these tailored affinity-coated magnetic beads in complex samples. We further show how cluster analysis, in conjunction with the use of nonspecific, inexpensive fluorescent dye, allows for a straightforward optical assessment of the bacterial load directly from urine samples. The optimized sensing protocol and related kits provide, in less than 60 min, qualitative (positive/negative) information on the bacterial load with 85% specificity and 96% sensitivity, which is appropriate to empower clinical microscopy with a new analytic dimension. The procedure is prone to automation, can be conveniently used in clinical microbiology laboratories and, since it preserves the viability of the captured bacteria, can be interfaced with downstream analyses and antimicrobial susceptibility testing. Moreover, the study emphasizes a suite of practical validation assays that are useful for bringing the tool-box of immunomagnetic materials outside the academic laboratory and into real-life applications. Full article
(This article belongs to the Special Issue Advanced Designs of Materials, Devices and Techniques for Biosensing)
Show Figures

Figure 1

18 pages, 4231 KB  
Article
Continuous Flow Labeling and In-Line Magnetic Separation of Cells
by Zhixi Qian, Thomas R. Hanley, Lisa M. Reece, James F. Leary, Eugene D. Boland and Paul Todd
Magnetochemistry 2022, 8(1), 5; https://doi.org/10.3390/magnetochemistry8010005 - 30 Dec 2021
Cited by 2 | Viewed by 4139
Abstract
There is an identified need for point-of-care diagnostic systems for detecting and counting specific rare types of circulating cells in blood. By adequately labeling such cells with immunomagnetic beads and quantum dots, they can be efficiently collected magnetically for quantification using fluorescence methods. [...] Read more.
There is an identified need for point-of-care diagnostic systems for detecting and counting specific rare types of circulating cells in blood. By adequately labeling such cells with immunomagnetic beads and quantum dots, they can be efficiently collected magnetically for quantification using fluorescence methods. Automation of this process requires adequate mixing of the labeling materials with blood samples. A static mixing device can be employed to improve cell labeling efficiency and eliminate error-prone laboratory operations. Computational fluid dynamics (CFD) were utilized to simulate the flow of a labeling-materials/blood mixture through a 20-stage in-line static mixer of the interfacial-surface-generator type. Optimal fluid mixing conditions were identified and tested in a magnetic bead/tumor cell model, and it was found that labeled cells could be produced at 1.0 mL/min flow rate and fed directly into an in-line magnetic trap. The trap design consists of a dual flow channel with three bends and a permanent magnet positioned at the outer curve of each bend. The capture of labeled cells in the device was simulated using CFD, finite-element analysis and magnetophoretic mobility distributions of labeled cells. Testing with cultured CRL14777 human melanoma cells labeled with anti-CD146 1.5 μm diameter beads indicated that 90 ± 10% are captured at the first stage, and these cells can be captured when present in whole blood. Both in-line devices were demonstrated to function separately and together as predicted. Full article
(This article belongs to the Special Issue Magnetic Cell Separation)
Show Figures

Figure 1

15 pages, 6554 KB  
Article
Exosomal Surface Protein Detection with Quantum Dots and Immunomagnetic Capture for Cancer Detection
by Vojtech Vinduska, Caleb Edward Gallops, Ryan O’Connor, Yongmei Wang and Xiaohua Huang
Nanomaterials 2021, 11(7), 1853; https://doi.org/10.3390/nano11071853 - 18 Jul 2021
Cited by 28 | Viewed by 6005
Abstract
Exosomes carry molecular contents reflective of parental cells and thereby hold great potential as a source of biomarkers for non-invasive cancer detection and monitoring. However, simple and rapid exosomal molecular detection remains challenging. Here, we report a facile method for exosome surface protein [...] Read more.
Exosomes carry molecular contents reflective of parental cells and thereby hold great potential as a source of biomarkers for non-invasive cancer detection and monitoring. However, simple and rapid exosomal molecular detection remains challenging. Here, we report a facile method for exosome surface protein detection using quantum dot coupled with immunomagnetic capture and enrichment. In this method, exosomes were captured by magnetic beads based on CD81 protein expression. Surface protein markers of interest were recognized by primary antibody and then detected by secondary antibody-conjugated quantum dot with fluorescent spectroscopy. Validated by ELISA, our method can specifically detect different surface markers on exosomes from different cancer cell lines and differentiate cancer exosomes from normal exosomes. The clinical potential was demonstrated with pilot plasma samples using HER2-positive breast cancer as the disease model. The results show that exosomes from HER2-positive breast cancer patients exhibited a five times higher level of HER2 expression than healthy controls. Exosomal HER2 showed strong diagnostic power for HER2-positive patients, with the area under the curve of 0.969. This quantum dot-based exosome method is rapid (less than 5 h) and only requires microliters of diluted plasma without pre-purification, practical for routine use for basic vesicle research, and clinical applications. Full article
(This article belongs to the Section Biology and Medicines)
Show Figures

Figure 1

11 pages, 2281 KB  
Letter
Effective Isolation for Lung Carcinoma Cells Based on Immunomagnetic Separation in a Microfluidic Channel
by Hien Vu-Dinh, Hui Feng and Chun-Ping Jen
Biosensors 2021, 11(1), 23; https://doi.org/10.3390/bios11010023 - 16 Jan 2021
Cited by 13 | Viewed by 4225
Abstract
In this paper, we developed an isolation system for A549 human lung carcinoma cells as an effective factor for the early diagnosis of lung cancer. A microfluidic immunomagnetic method was used, in which the combination of immunomagnetic separation and a microfluidic system allowed [...] Read more.
In this paper, we developed an isolation system for A549 human lung carcinoma cells as an effective factor for the early diagnosis of lung cancer. A microfluidic immunomagnetic method was used, in which the combination of immunomagnetic separation and a microfluidic system allowed for increased isolation efficiency with uncomplicated manipulation. In the microfluidic immunomagnetic strategy, A549 cells were combined with aptamer-conjugated carboxylated magnetic beads and then collected in a specified region by applying a magnetic field. The results were recorded using a fluorescence microscope, and the captured targets were then quantified. The isolation efficiency of A549 cells is up to 77.8%. This paper developed a simple working procedure, which is less time consuming, high-throughput, and trustworthy for the isolation of A549 cells. This procedure can be a useful reference method for the development of an effective diagnosis and treatment method for lung cancer in the future. Full article
(This article belongs to the Special Issue Aptamers to Replace Antibodies for in vitro Diagnostics)
Show Figures

Figure 1

12 pages, 1958 KB  
Communication
Microbubbles-Assisted Ultrasound Triggers the Release of Extracellular Vesicles
by Yuana Yuana, Linglei Jiang, Bart H. A. Lammertink, Pieter Vader, Roel Deckers, Clemens Bos, Raymond M. Schiffelers and Chrit T. Moonen
Int. J. Mol. Sci. 2017, 18(8), 1610; https://doi.org/10.3390/ijms18081610 - 25 Jul 2017
Cited by 46 | Viewed by 7693
Abstract
Microbubbles-assisted ultrasound (USMB) has shown promise in improving local drug delivery. The formation of transient membrane pores and endocytosis are reported to be enhanced by USMB, and they contribute to cellular drug uptake. Exocytosis also seems to be linked to endocytosis upon USMB [...] Read more.
Microbubbles-assisted ultrasound (USMB) has shown promise in improving local drug delivery. The formation of transient membrane pores and endocytosis are reported to be enhanced by USMB, and they contribute to cellular drug uptake. Exocytosis also seems to be linked to endocytosis upon USMB treatment. Based on this rationale, we investigated whether USMB triggers exocytosis resulting in the release of extracellular vesicles (EVs). USMB was performed on a monolayer of head-and-neck cancer cells (FaDu) with clinically approved microbubbles and commonly used ultrasound parameters. At 2, 4, and 24 h, cells and EV-containing conditioned media from USMB and control conditions (untreated cells, cells treated with microbubbles and ultrasound only) were harvested. EVs were measured using flow cytometric immuno-magnetic bead capture assay, immunogold electron microscopy, and western blotting. After USMB, levels of CD9 exposing-EVs significantly increased at 2 and 4 h, whereas levels of CD63 exposing-EVs increased at 2 h. At 24 h, EV levels were comparable to control levels. EVs released after USMB displayed a heterogeneous size distribution profile (30–1200 nm). Typical EV markers CD9, CD63, and alix were enriched in EVs released from USMB-treated FaDu cells. In conclusion, USMB treatment triggers exocytosis leading to the release of EVs from FaDu cells. Full article
(This article belongs to the Section Molecular Pathology, Diagnostics, and Therapeutics)
Show Figures

Graphical abstract

8 pages, 1062 KB  
Article
Rapid Detection of Bacillus anthracis Spores Using Immunomagnetic Separation and Amperometry
by David F. Waller, Brian E. Hew, Charlie Holdaway, Michael Jen and Gabriel D. Peckham
Biosensors 2016, 6(4), 61; https://doi.org/10.3390/bios6040061 - 20 Dec 2016
Cited by 24 | Viewed by 10182
Abstract
Portable detection and quantitation methods for Bacillus anthracis (anthrax) spores in pure culture or in environmental samples are lacking. Here, an amperometric immunoassay has been developed utilizing immunomagnetic separation to capture the spores and remove potential interferents from test samples followed by amperometric [...] Read more.
Portable detection and quantitation methods for Bacillus anthracis (anthrax) spores in pure culture or in environmental samples are lacking. Here, an amperometric immunoassay has been developed utilizing immunomagnetic separation to capture the spores and remove potential interferents from test samples followed by amperometric measurement on a field-portable instrument. Antibody-conjugated magnetic beads and antibody-conjugated glucose oxidase were used in a sandwich format for the capture and detection of target spores. Glucose oxidase activity of spore pellets was measured indirectly via amperometry by applying a bias voltage after incubation with glucose, horseradish peroxidase, and the electron mediator 2,2′-azino-bis (3-ethylbenzthiazoline-6-sulphonic acid). Target capture was mediated by polyclonal antisera, whereas monoclonal antibodies were used for signal generation. This strategy maximized sensitivity (500 target spores, 5000 cfu/mL), while also providing a good specificity for Bacillus anthracis spores. Minimal signal deviation occurs in the presence of environmental interferents including soil and modified pH conditions, demonstrating the strengths of immunomagnetic separation. The simultaneous incubation of capture and detection antibodies and rapid substrate development (5 min) result in short sample-to-signal times (less than an hour). With attributes comparable or exceeding that of ELISA and LFDs, amperometry is a low-cost, low-weight, and practical method for detecting anthrax spores in the field. Full article
(This article belongs to the Special Issue Point-of-Care Diagnostics)
Show Figures

Figure 1

Back to TopTop