Sign in to use this feature.

Years

Between: -

Subjects

remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline

Journals

Article Types

Countries / Regions

remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline

Search Results (233)

Search Parameters:
Keywords = electrochemical chip

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
20 pages, 3332 KiB  
Review
Nafion in Biomedicine and Healthcare
by Antonios Kelarakis
Polymers 2025, 17(15), 2054; https://doi.org/10.3390/polym17152054 - 28 Jul 2025
Viewed by 361
Abstract
Nafion has long been recognized as the gold standard for proton exchange membranes, due to its exceptional ion exchange capacity and its advanced performance in chemically aggressive environments. In recent years, a growing body of evidence has demonstrated that Nafion is equally well-suited [...] Read more.
Nafion has long been recognized as the gold standard for proton exchange membranes, due to its exceptional ion exchange capacity and its advanced performance in chemically aggressive environments. In recent years, a growing body of evidence has demonstrated that Nafion is equally well-suited in complex biological conditions owing to its structural robustness, responsive functionality and intrinsic biocompatibility. These characteristics have enabled its transition into the biomedical and healthcare sectors, where it is currently being explored for a diverse and expanding range of applications. To that end, Nafion has been systematically investigated as a key component in bioelectronic systems for energy harvest, sensors, wearable electronics, tissue engineering, lab-on-a-chip platforms, implants, controlled drug delivery systems and antimicrobial surface coatings. This review examines the distinctive structural and electrochemical characteristics that underpin Nafion’s performance in these biomedical contexts, provides an overview of recent advancements, emphasizes critical performance metrics and highlights the material’s growing potential to shape the future of biomedical technology. Full article
(This article belongs to the Section Smart and Functional Polymers)
Show Figures

Figure 1

14 pages, 1765 KiB  
Article
Microfluidic System Based on Flexible Structures for Point-of-Care Device Diagnostics with Electrochemical Detection
by Kasper Marchlewicz, Robert Ziółkowski, Kamil Żukowski, Jakub Krzemiński and Elżbieta Malinowska
Biosensors 2025, 15(8), 483; https://doi.org/10.3390/bios15080483 - 24 Jul 2025
Viewed by 390
Abstract
Infectious diseases poses a growing public health challenge. The COVID-19 pandemic has further emphasized the urgent need for rapid, accessible diagnostics. This study presents the development of an integrated, flexible point-of-care (POC) diagnostic system for the rapid detection of Corynebacterium diphtheriae, the [...] Read more.
Infectious diseases poses a growing public health challenge. The COVID-19 pandemic has further emphasized the urgent need for rapid, accessible diagnostics. This study presents the development of an integrated, flexible point-of-care (POC) diagnostic system for the rapid detection of Corynebacterium diphtheriae, the pathogen responsible for diphtheria. The system comprises a microfluidic polymerase chain reaction (micro-PCR) device and an electrochemical DNA biosensor, both fabricated on flexible substrates. The micro-PCR platform offers rapid DNA amplification overcoming the time limitations of conventional thermocyclers. The biosensor utilizes specific molecular recognition and an electrochemical transducer to detect the amplified DNA fragment, providing a clear and direct indication of the pathogen’s presence. The combined system demonstrates the effective amplification and detection of a gene fragment from a toxic strain of C. diphtheriae, chosen due to its increasing incidence. The design leverages lab-on-a-chip (LOC) and microfluidic technologies to minimize reagent use, reduce cost, and support portability. Key challenges in microsystem design—such as flow control, material selection, and reagent compatibility—were addressed through optimized fabrication techniques and system integration. This work highlights the feasibility of using flexible, integrated microfluidic and biosensor platforms for the rapid, on-site detection of infectious agents. The modular and scalable nature of the system suggests potential for adaptation to a wide range of pathogens, supporting broader applications in global health diagnostics. The approach provides a promising foundation for next-generation POC diagnostic tools. Full article
(This article belongs to the Special Issue Microfluidics for Sample Pretreatment)
Show Figures

Figure 1

15 pages, 2102 KiB  
Article
MXene-Based Flexible Paper Chip for Glucose Detection in Sweat in Low-Temperature Environments
by Yandong Yang, Yajun Zhu, Yifei Wu, Fan Chang, Xu Zhu, Xinyue Zhang, Ning Ma, Yushu Wang and Alaa S. Abd-El-Aziz
Sensors 2025, 25(14), 4273; https://doi.org/10.3390/s25144273 - 9 Jul 2025
Viewed by 416
Abstract
In enzymatic reaction glucose detection chips, the enzyme can easily dislodge from the electrode, which harms both the chip and test stability. Additionally, enzyme activity significantly decreases at low temperatures. Consequently, immobilizing the enzyme at the appropriate substrate and ambient temperature is a [...] Read more.
In enzymatic reaction glucose detection chips, the enzyme can easily dislodge from the electrode, which harms both the chip and test stability. Additionally, enzyme activity significantly decreases at low temperatures. Consequently, immobilizing the enzyme at the appropriate substrate and ambient temperature is a critical step for improving the chip. To address this issue, an electrochemical detection chip was modified using the nanomaterial MXene, known for its large specific surface area, excellent adsorption, good dispersion, and high conductivity. Meanwhile, AgNO3 solution was added to the Ti3C2Tx MXene nanosheet solution, and the AgNP@MXene material was prepared by heating in a water bath. This process further enhances photothermal conversion efficiency due to the localized surface plasmon resonance effect of silver nanoparticles and MXene. This MXene-based photothermally enhanced paper chip exhibits outstanding photothermal conversion performance and sensitive photoelectrochemical responsiveness, along with good cycling stability. Moreover, improved glucose detection sensitivity at low winter temperatures has been achieved, and the ambient temperature range of the paper chip has been expanded to 25–37 °C. Full article
(This article belongs to the Special Issue The Advanced Flexible Electronic Devices: 2nd Edition)
Show Figures

Figure 1

13 pages, 2341 KiB  
Article
Flexible Hydrophobic Paper-Based Microfluidic Field-Effect Biosensor Amplified by RNA-Cleaving DNAzyme-Based DNA Nanostructure for Mg2+ Detection
by Hui Wang, Yue He, Zhixue Yu, Ruipeng Chen, Zemeng Feng, Dongfei Chen, Waleid Mohamed El-Sayed Shakweer, Fan Zhang, Xuemei Nan, Mukaddas Mijit, Benhai Xiong, Liang Yang and Xiangfang Tang
Biosensors 2025, 15(7), 405; https://doi.org/10.3390/bios15070405 - 24 Jun 2025
Viewed by 465
Abstract
Magnesium ions (Mg2+) play an important role in animal health, with their concentration in the bloodstream serving as a key indicator for hypomagnesemia diagnosis. In this study, a flexible hydrophobic paper-based microfluidic field-effect biosensor was developed for point-of-care Mg2+ detection, [...] Read more.
Magnesium ions (Mg2+) play an important role in animal health, with their concentration in the bloodstream serving as a key indicator for hypomagnesemia diagnosis. In this study, a flexible hydrophobic paper-based microfluidic field-effect biosensor was developed for point-of-care Mg2+ detection, which integrated flexible hydrophobic paper, semiconducting single-walled carbon nanotubes (SWNTs) and a Mg2+-specific RNA-cleaving DNAzyme(RCD)-based DNA nanostructure. Flexible hydrophobic paper was synthesized by using cellulose paper and octadecyltrichlorosilane, improving mechanical strength and decreasing biological interference. To achieve high sensitivity, the Mg2+-specific RCD was functionalized with SWNTs, and then repeatedly self-assembled two different Y-shaped DNAs to construct a DNA nanostructure based on a similar DNA origami technique. This proposed biosensor exhibited a linear detection range from 1 μM to 1000 μM, with a detection limit of 0.57 μM, demonstrating its great stability, selectivity, and anti-interference performance. This innovative design offers promising potential for Mg2+ monitoring in real applications. Full article
(This article belongs to the Special Issue Design and Application of Microfluidic Biosensors in Biomedicine)
Show Figures

Figure 1

25 pages, 3505 KiB  
Review
Micro- and Nanoengineered Devices for Rapid Chemotaxonomic Profiling of Medicinal Plants
by Sajid Ali, Adnan Amin, Muhammad Saeed Akhtar and Wajid Zaman
Nanomaterials 2025, 15(12), 899; https://doi.org/10.3390/nano15120899 - 10 Jun 2025
Viewed by 605
Abstract
Chemotaxonomic profiling based on secondary metabolites offers a reliable approach for identifying and authenticating medicinal plants, addressing limitations associated with traditional morphological and genetic methods. Recent advances in microfluidics and nanoengineered technologies—including lab-on-a-chip systems as well as nano-enabled optical and electrochemical sensors—enable the [...] Read more.
Chemotaxonomic profiling based on secondary metabolites offers a reliable approach for identifying and authenticating medicinal plants, addressing limitations associated with traditional morphological and genetic methods. Recent advances in microfluidics and nanoengineered technologies—including lab-on-a-chip systems as well as nano-enabled optical and electrochemical sensors—enable the rapid, accurate, and portable detection of key metabolites, such as alkaloids, flavonoids, terpenoids, and phenolics. Integrating artificial intelligence and machine learning techniques further enhances the analytical capabilities of these technologies, enabling automated, precise plant identification in field-based applications. Therefore, this review aims to highlight the potential applications of micro- and nanoengineered devices in herbal medicine markets, medicinal plant authentication, and biodiversity conservation. We discuss strategies to address current challenges, such as biocompatibility and material toxicity, technical limitations in device miniaturization, and regulatory and standardization requirements. Furthermore, we outline future trends and innovations necessary to fully realize the transformative potential of these technologies in real-world chemotaxonomic applications. Full article
(This article belongs to the Section Nanofabrication and Nanomanufacturing)
Show Figures

Figure 1

12 pages, 9594 KiB  
Article
An Electrochemical Sensor Based on AuNPs@Cu-MOF/MWCNTs Integrated Microfluidic Device for Selective Monitoring of Hydroxychloroquine in Human Serum
by Xuanlin Feng, Jiaqi Zhao, Shiwei Wu, Ying Kan, Honemei Li and Weifei Zhang
Chemosensors 2025, 13(6), 200; https://doi.org/10.3390/chemosensors13060200 - 1 Jun 2025
Viewed by 730
Abstract
Hydroxychloroquine (HCQ), a cornerstone therapeutic agent for autoimmune diseases, requires precise serum concentration monitoring due to its narrow therapeutic window. Current HCQ monitoring methods such as HPLC and LC-MS/MS are sensitive but costly and complex. While electrochemical sensors offer rapid, cost-effective detection, their [...] Read more.
Hydroxychloroquine (HCQ), a cornerstone therapeutic agent for autoimmune diseases, requires precise serum concentration monitoring due to its narrow therapeutic window. Current HCQ monitoring methods such as HPLC and LC-MS/MS are sensitive but costly and complex. While electrochemical sensors offer rapid, cost-effective detection, their large chambers and high sample consumption hinder point-of-care use. To address these challenges, we developed a microfluidic electrochemical sensing platform based on a screen-printed carbon electrode (SPCE) modified with a hierarchical nanocomposite of gold nanoparticles (AuNPs), copper-based metal–organic frameworks (Cu-MOFs), and multi-walled carbon nanotubes (MWCNTs). The Cu-MOF provided high porosity and analyte enrichment, MWCNTs established a 3D conductive network to enhance electron transfer, and AuNPs further optimized catalytic activity through localized plasmonic effects. Structural characterization (SEM, XRD, FT-IR) confirmed the successful integration of these components via π-π stacking and metal–carboxylate coordination. Electrochemical analyses (CV, EIS, DPV) revealed exceptional performance, with a wide linear range (0.05–50 μM), a low detection limit (19 nM, S/N = 3), and a rapid response time (<5 min). The sensor exhibited outstanding selectivity against common interferents, high reproducibility (RSD = 3.15%), and long-term stability (98% signal retention after 15 days). By integrating the nanocomposite-modified SPCE into a microfluidic chip, we achieved accurate HCQ detection in 50 μL of serum, with recovery rates of 95.0–103.0%, meeting FDA validation criteria. This portable platform combines the synergistic advantages of nanomaterials with microfluidic miniaturization, offering a robust and practical tool for real-time therapeutic drug monitoring in clinical settings. Full article
(This article belongs to the Special Issue Feature Papers on Luminescent Sensing (Second Edition))
Show Figures

Figure 1

47 pages, 2529 KiB  
Review
Microfluidic Electrochemical Desalination Systems: A Review
by Waad H. Abuwatfa, Haya Taleb, Nour AlSawaftah, Khaled Chahrour, Ghaleb A. Husseini and Naif Darwish
Water 2025, 17(11), 1601; https://doi.org/10.3390/w17111601 - 25 May 2025
Viewed by 935
Abstract
Microfluidic techniques have emerged as promising, efficient, cost-effective, and environmentally friendly desalination solutions. By utilizing fluid dynamics at the microscale, these techniques offer precise control over chemical, biological, and physical processes, presenting advantages such as reduced energy consumption, miniaturization, portability, and enhanced process [...] Read more.
Microfluidic techniques have emerged as promising, efficient, cost-effective, and environmentally friendly desalination solutions. By utilizing fluid dynamics at the microscale, these techniques offer precise control over chemical, biological, and physical processes, presenting advantages such as reduced energy consumption, miniaturization, portability, and enhanced process control. A significant challenge in scaling microfluidic desalination for macro applications is the disparity in flow rates. Current devices operate at microliters per minute, while practical applications require liters daily. Solutions involve integrating multiple units on a single chip and developing stackable chip designs. Innovative designs, such as 3D microfluidic chips, have shown promise in enhancing scalability. Fouling, particularly in seawater environments, presents another major challenge. Addressing fouling through advanced materials, including graphene and nanomaterials, is critical to improving the efficiency and longevity of devices. Advances in microfluidic device fabrication, such as photo-patterned hydrogel membranes and 3D printing, have increased device complexity and affordability. Hybrid fabrication approaches could further enhance membrane quality and efficiency. Energy consumption remains a concern, necessitating research into more energy-efficient designs and integration with renewable energy sources. This paper explores various electrochemical-based microfluidic desalination methods, including dialysis/electrodialysis, capacitive deionization (CDI)/electrochemical capacitive deionization (ECDI), ion concentration polarization (ICP), and electrochemical desalination (ECD). Full article
(This article belongs to the Section Water Quality and Contamination)
Show Figures

Figure 1

16 pages, 3092 KiB  
Article
MIP-Modified Porous Silicon Optical Sensor for Interleukin-6 Label-Free Quantification
by Valeria Nocerino, Giulia Siciliano, Monica Bianco, Ilaria Rea, Principia Dardano, Maria Serena Chiriacò, Francesco Ferrara, Giuseppe Gigli, Elisabetta Primiceri and Luca De Stefano
Biosensors 2025, 15(5), 320; https://doi.org/10.3390/bios15050320 - 17 May 2025
Viewed by 619
Abstract
In this study, we present an innovative optical biosensor designed to detect Interleukin-6 (IL-6), a pivotal cytokine implicated in many pathological conditions. Our sensing platform is made of a porous silicon (PSi) nanostructured substrate modified with a thin (~5 nm) molecularly imprinted polymer [...] Read more.
In this study, we present an innovative optical biosensor designed to detect Interleukin-6 (IL-6), a pivotal cytokine implicated in many pathological conditions. Our sensing platform is made of a porous silicon (PSi) nanostructured substrate modified with a thin (~5 nm) molecularly imprinted polymer (MIP), ensuring both high specificity and sensitivity toward IL-6 molecules. The fabrication process involves electrochemical etching of silicon chips to create the porous structure, followed by the electrodeposition of the MIP, which is tailored to selectively bind the IL-6 target. Extensive testing over a broad IL-6 concentration range demonstrates a clear, proportional optical response, yielding a limit of detection (LOD) of 13 nM. Moreover, the biosensor robustness was verified by evaluating its performance in bovine serum, a complex biological matrix. Despite the presence of various interfering components, the sensor maintained its selectivity and displayed minimal matrix effects, underlining its practical applicability in real-world diagnostic scenarios. Full article
(This article belongs to the Section Biosensor and Bioelectronic Devices)
Show Figures

Figure 1

20 pages, 5758 KiB  
Review
Innovative Microfluidic Technologies for Rapid Heavy Metal Ion Detection
by Muhammad Furqan Rauf, Zhenda Lin, Muhammad Kamran Rauf and Jin-Ming Lin
Chemosensors 2025, 13(4), 149; https://doi.org/10.3390/chemosensors13040149 - 18 Apr 2025
Cited by 1 | Viewed by 1473
Abstract
Heavy metal ion (HMI) contamination poses significant threats to public health and environmental safety, necessitating advanced detection technologies that are rapid, sensitive, and field-deployable. While conventional methods like atomic absorption spectroscopy (AAS) and inductively coupled plasma mass spectrometry (ICP-MS) remain prevalent, their limitations—including [...] Read more.
Heavy metal ion (HMI) contamination poses significant threats to public health and environmental safety, necessitating advanced detection technologies that are rapid, sensitive, and field-deployable. While conventional methods like atomic absorption spectroscopy (AAS) and inductively coupled plasma mass spectrometry (ICP-MS) remain prevalent, their limitations—including high costs, complex workflows, and lack of portability—underscore the urgent need for innovative alternatives. This review consolidates advancements in the last five years in microfluidic technologies for HMI detection, emphasizing their transformative potential through miniaturization, integration, and automation. We critically evaluate the synergy of microfluidics with cutting-edge materials (e.g., graphene and quantum dots) and detection mechanisms (electrochemical, optical, and colorimetric), enabling ultra-trace detection at parts-per-billion (ppb) levels. We highlight novel device architectures, such as polydimethylsiloxane (PDMS)-based labs-on-chip (LOCs), paper-based microfluidics, 3D-printed systems, and digital microfluidics (DMF), which offer unparalleled portability, cost-effectiveness, and multiplexing capabilities. Additionally, we address persistent challenges (e.g., selectivity and scalability) and propose future directions, including AI integration and sustainable fabrication. By bridging gaps between laboratory research and practical deployment, this review provides a roadmap for next-generation microfluidic solutions, positioning them as indispensable tools for global HMI monitoring. Full article
Show Figures

Figure 1

13 pages, 3236 KiB  
Article
Detection of Ammonia Nitrogen in Neutral Aqueous Solutions Based on In Situ Modulation Using Ultramicro Interdigitated Array Electrode Chip
by Yuqi Liu, Nan Qiu, Zhihao Zhang, Yang Li and Chao Bian
Chemosensors 2025, 13(4), 138; https://doi.org/10.3390/chemosensors13040138 - 9 Apr 2025
Viewed by 2376
Abstract
In this study, an in situ electrochemical modulation method based on an ultramicro interdigitated array electrode (UIAE) sensor chip was developed for the detection of ammonia nitrogen (NH3-N) in neutral aqueous solutions. One comb of the UIAE was used as the [...] Read more.
In this study, an in situ electrochemical modulation method based on an ultramicro interdigitated array electrode (UIAE) sensor chip was developed for the detection of ammonia nitrogen (NH3-N) in neutral aqueous solutions. One comb of the UIAE was used as the working electrode for both the modulating and sensing functions, while the other comb was used as the counter electrode. Utilizing its enhanced mass transfer and proximity effects, the feasibility of in situ modulation of the solution environment near the UIAE chip to generate an electrochemical response for NH3-N was investigated using electrochemical methods. The proposed method enhances the concentration of hydroxide ions and active chloride in the local solution near the sensor chip. These reactive species play a key role in improving the sensor’s electrocatalytic oxidation capability toward ammonia nitrogen, facilitating the sensitive detection of ammonia nitrogen in neutral environments. A linear relationship was displayed, ranging from 0.15–2.0 mg/L (as nitrogen) with a sensitivity of 3.7936 µA·L·mg−1 (0.0664 µA µM−1 mm−2), which was 2.45 times that in strong alkaline conditions without modulation. Additionally, the relative standard deviation of the measurement remained below 2.9% over five days of repeated experiments, indicating excellent stability. Full article
(This article belongs to the Special Issue Advancements of Chemosensors and Biosensors in China—2nd Edition)
Show Figures

Figure 1

14 pages, 3362 KiB  
Article
A Microelectrode Sensor Chip for Detecting Mercury and Arsenic with Wide Concentration Ranges
by Zhihao Zhang, Yuqi Liu, Yang Li and Chao Bian
Chemosensors 2025, 13(4), 129; https://doi.org/10.3390/chemosensors13040129 - 3 Apr 2025
Viewed by 2704
Abstract
Traditional detection methods such as atomic absorption spectroscopy offer high sensitivity and accuracy for heavy metal ion detection; however, they are often limited to laboratory environments due to bulky equipment and complex procedures. To meet the demand for rapid on-site detection, this study [...] Read more.
Traditional detection methods such as atomic absorption spectroscopy offer high sensitivity and accuracy for heavy metal ion detection; however, they are often limited to laboratory environments due to bulky equipment and complex procedures. To meet the demand for rapid on-site detection, this study employs electrochemical analysis and utilizes Micro-Electro-Mechanical Systems (MEMS) technology to fabricate a microelectrode sensor chip for the electrochemical detection of heavy metal ions, Hg(II) and As(III). Nano-gold particles were electrodeposited on the sensing area of the working electrode of this chip using a constant-potential deposition method. Uniform distribution of the nanoparticles was obtained, which enhanced the effective specific surface area and electrochemical activity of the working electrode. Therefore, wide detection concentration ranges for Hg(II) of 5 to 1000 µg/L and for As(III) of 5 to 5000 µg/L were displayed, with detection limits of 1.4 µg/L and 2.4 µg/L, respectively. Moreover, the sensor exhibited satisfactory reproducibility, stability and anti-interference capability. These characteristics enable the developed microelectrode sensor chip to be utilized in the monitoring of a diverse range of pollution sources. Full article
(This article belongs to the Special Issue Advancements of Chemosensors and Biosensors in China—2nd Edition)
Show Figures

Figure 1

15 pages, 3413 KiB  
Article
Hybridization Chain Reaction-Enhanced Ultrasensitive Electrochemical Analysis of miRNAs with a Silver Nano-Reporter on a Gold Nanostructured Electrode Array
by Bin Wang, Huiqiang Ma, Mingxing Zhou, Xian Huang, Ying Gan and Hong Yang
J. Funct. Biomater. 2025, 16(3), 98; https://doi.org/10.3390/jfb16030098 - 12 Mar 2025
Cited by 1 | Viewed by 891
Abstract
Abnormal expression of miRNAs is associated with the occurrence and progression of cancer and other diseases, making miRNAs essential biomarkers for disease diagnosis and prognosis. However, the intrinsic properties of miRNAs, such as short length, low abundance, and high sequence homology, represent great [...] Read more.
Abnormal expression of miRNAs is associated with the occurrence and progression of cancer and other diseases, making miRNAs essential biomarkers for disease diagnosis and prognosis. However, the intrinsic properties of miRNAs, such as short length, low abundance, and high sequence homology, represent great challenges for fast and accurate miRNA detection in clinics. Herein, we developed a novel hybridization chain reaction (HCR)-based electrochemical miRNAs chip (e-miRchip), featured with gold nanostructured electrodes (GNEs) and silver nanoparticle reporters (AgNRs), for sensitive and multiplexed miRNA detection. AgNRs were synthesized and applied on the e-miRchip to generate strong redox signals in the presence of miRNA. The stem–loop capture probe was covalently immobilized on the GNEs, and was opened upon miRNA hybridization to consequently trigger the HCR for signal amplification. The multiple long-repeated DNA helix generated by HCR provides the binding sites for the AgNRs, contributing to the amplification of the electrochemical signals of miRNA hybridization. To optimize the detection sensitivity, GNEs with three distinct structures were electroplated, in which flower-like GNEs were found to be the best electrode morphology for miRNAs analysis. Under optimal conditions, the HCR-based e-miRchip showed an excellent detection performance with an LOD of 0.9 fM and a linear detection range from 1 fM to 10 pM. Moreover, this HCR-based e-miRchip platform was able to effectively distinguish miRNAs from the one- or two-base mismatches. This HCR-based e-miRchip holds great potential as a highly efficient and promising miRNA detection platform for the diagnosis and prognosis of cancer and other diseases in the future. Full article
(This article belongs to the Special Issue Women’s Special Issue Series: Functional Biomaterials (2nd Edition))
Show Figures

Figure 1

13 pages, 4135 KiB  
Article
On-Chip Electrochemical Sensor Based on 3D Graphene Assembly Decorated Ultrafine RuCu Alloy Nanocatalyst for In Situ Detection of NO in Living Cells
by Haibo Liu, Kaiyuan Yao, Min Hu, Shanting Li, Shengxiong Yang and Anshun Zhao
Nanomaterials 2025, 15(6), 417; https://doi.org/10.3390/nano15060417 - 8 Mar 2025
Cited by 1 | Viewed by 935
Abstract
In this work, we developed 3D ionic liquid (IL) functionalized graphene assemblies (GAs) decorated by ultrafine RuCu alloy nanoparticles (RuCu-ANPs) via a one-step synthesis process, and integrated it into a microfluidic sensor chip for in situ electrochemical detection of NO released from living [...] Read more.
In this work, we developed 3D ionic liquid (IL) functionalized graphene assemblies (GAs) decorated by ultrafine RuCu alloy nanoparticles (RuCu-ANPs) via a one-step synthesis process, and integrated it into a microfluidic sensor chip for in situ electrochemical detection of NO released from living cells. Our findings have demonstrated that RuCu-ANPs on 3D IL-GA exhibit high density, uniform distribution, lattice-shaped arrangement of atoms, and extremely ultrafine size, and possess high electrocatalytic activity to NO oxidation on the electrode. Meanwhile, the 3D IL-GA with hierarchical porous structures can facilitate the efficient electron/mass transfer at the electrode/electrolyte interface and the cell culture. Moreover, the graft of IL molecules on GA endows it with high hydrophilicity for facile and well-controllable printing on the electrode. Consequently, the resultant electrochemical microfluidic sensor demonstrated excellent sensing performances including fast response time, high sensitivity, good anti-interference ability, high reproducibility, long-term stability, as well as good biocompatibility, which can be used as an on-chip sensing system for cell culture and real-time in situ electrochemical detection of NO released from living cells with accurate and stable characteristics in physiological conditions. Full article
(This article belongs to the Special Issue The 15th Anniversary of Nanomaterials—Women in Nanomaterials)
Show Figures

Graphical abstract

41 pages, 3280 KiB  
Review
A Review of Recent Developments in Analytical Methods for Determination of Phosphorus from Environmental Samples
by Tumelo M. Mogashane, Odwa Mapazi, Moshalagae A. Motlatle, Lebohang Mokoena and James Tshilongo
Molecules 2025, 30(5), 1001; https://doi.org/10.3390/molecules30051001 - 21 Feb 2025
Cited by 5 | Viewed by 3548
Abstract
Phosphorus is essential to environmental systems because it affects both agricultural productivity and ecological balance. Since it contributes to eutrophication and pollution problems, its existence in a variety of environmental matrices, including soil, water, and air, necessitates precise and effective determination methods for [...] Read more.
Phosphorus is essential to environmental systems because it affects both agricultural productivity and ecological balance. Since it contributes to eutrophication and pollution problems, its existence in a variety of environmental matrices, including soil, water, and air, necessitates precise and effective determination methods for monitoring and managing its levels. This review paper provides an extensive overview of the latest advancements in analytical techniques for measuring phosphorus in environmental samples. We investigate sophisticated spectroscopic, chromatographic, and electrochemical techniques in addition to conventional approaches like colorimetric analysis. Innovative techniques such as mass spectrometry (MS), X-ray fluorescence (XRF) spectrometry, and nuclear magnetic resonance (NMR) spectroscopy are also highlighted in this study, along with newly developed technologies such as biosensors, lab-on-a-chip devices, and nanotechnology-based techniques. Real-time and field-deployable monitoring technologies are also covered, with a focus on their advantages and usefulness. Among the techniques reviewed, XRF and colorimetry methods have proven to be the most reliable due to their precision, cost-effectiveness, and adaptability for different sample matrices. While emerging spectroscopic and electrochemical techniques offer promising alternatives, further validation and standardization are needed for routine environmental monitoring. Future research should focus on integrating automated and high-throughput techniques to enhance monitoring capabilities further. Full article
(This article belongs to the Special Issue Novel Analytical Methods to Evaluate and Monitor the Pollutants)
Show Figures

Figure 1

15 pages, 4711 KiB  
Article
Evaluation of Cancer Cell Invasion Ability Based on Electrochemical Impedance
by Feiyang Jiang, Mingji Wei, Si Chen, Yanfei Wang, Ning Liu and Ning Yang
Biosensors 2025, 15(2), 91; https://doi.org/10.3390/bios15020091 - 6 Feb 2025
Viewed by 1319
Abstract
Cancer metastasis is the leading cause of cancer-related deaths, with the ability of cancer cells to invade blood vessels or lymphatic systems, determining their metastatic potential. Therefore, the rapid and accurate assessment of cell invasiveness is crucial. Current methods, such as the Transwell [...] Read more.
Cancer metastasis is the leading cause of cancer-related deaths, with the ability of cancer cells to invade blood vessels or lymphatic systems, determining their metastatic potential. Therefore, the rapid and accurate assessment of cell invasiveness is crucial. Current methods, such as the Transwell assay and fluorescent labeling, are complex, invasive, and may disrupt the physiological state of live cells. In this study, we introduce an electrochemical impedance-based method for evaluating cancer cell invasiveness, combining Transwell and microfluidic technologies to monitor the invasion process in a dynamic environment. A stable microfluidic chip with 30 μm interdigital electrodes was developed, optimized for HeLa cell detection. We identified 1 kHz as the optimal frequency for achieving the maximum impedance resolution of cancer cell invasiveness. By correlating the impedance response of Zcells/Zno-cells with invasiveness, we established a reliable electrochemical model. This model was validated with a hydrogen peroxide cytotoxicity assay, showing a high correlation with optical staining and a minimal error of 1.89%, underscoring its potential for drug efficacy prediction. The proposed method offers rapid detection, low cost, and requires no manual intervention, making it an efficient and reliable tool for assessing cancer cell invasiveness in therapeutic research. Full article
(This article belongs to the Special Issue Cellular Sensing and Precision Medicine)
Show Figures

Figure 1

Back to TopTop