Sign in to use this feature.

Years

Between: -

Subjects

remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline

Journals

Article Types

Countries / Regions

Search Results (87)

Search Parameters:
Keywords = doubly-fed induction machine

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
32 pages, 9166 KB  
Article
Vibration Assessment Due to Stator and Rotor Interturn Faults in a Doubly Fed Induction Generator for Wind Turbine Application
by Aakriti Gupta and Thanga Raj Chelliah
Energies 2026, 19(12), 2917; https://doi.org/10.3390/en19122917 (registering DOI) - 20 Jun 2026
Abstract
All rotating electrical machines are susceptible to vibrations arising from electromagnetic (EM) forces, electrical faults, mechanical defects, imbalance, and structural resonance. In Doubly Fed Induction Generators (DFIGs), such electromechanical vibrations are especially important because they can degrade reliability, increase noise, and lead to [...] Read more.
All rotating electrical machines are susceptible to vibrations arising from electromagnetic (EM) forces, electrical faults, mechanical defects, imbalance, and structural resonance. In Doubly Fed Induction Generators (DFIGs), such electromechanical vibrations are especially important because they can degrade reliability, increase noise, and lead to severe damage if resonance-prone operating conditions are not identified in time. Although fault diagnosis in DFIGs has been widely investigated using current, voltage, and flux signatures, comparatively fewer studies have examined fault-specific vibration behaviour under stator and rotor interturn faults (ITTFs), particularly through a coupled EM structural framework. In addition, prior vibration-based studies have not examined the influence of end winding ITTFs, its location, severity, and modal interaction investigating resonance risk. This paper considers vibration characteristics of a variable-speed 2.8 MW DFIG used in a grid-connected Type-3 wind turbine unit (WTU) at no-load operating condition. The DFIG is modelled in ANSYS Academic Research v 2022 R2 Maxwell for EM behaviour assessment for ITTFs in both stator and rotor windings along with modal analysis (MA) in ANSYS Workbench to examine the undamped stator and rotor modes over a range of frequencies. This coupled approach enables identification of vibration signatures associated with different ITTF types. The results show the magnetic flux density near faulty end-winding region increases with fault severity and ranges from 4.19 T to 4.39 T in proximity to faulty windings. A dominant modal frequency band of 60–65 Hz is identified, where stator and rotor modes coincide, creating probable resonance conditions. A severe vibration response is observed for single-phase stator ITTF, showing an amplitude of 2116 mm/s at 480 Hz for a larger number of shorted turns, indicating that asymmetric faults can produce stronger EM excitation than multi-phase faults. The main contribution of this paper is demonstration of a fault-specific, MA and vibration-based Condition monitoring system (CMS) implementation workflow for a DFIG. Unlike prior vibration-based studies that primarily focus on general machine vibration, mechanical faults, bearings, etc., this paper links stator and rotor ITTF induced EM excitation to modal characteristics, resonance behaviour, and measurable vibration signatures, establishing vibration analysis (VA) as a practical complementary technique for CMS of ITTFs in DFIGs. Full article
Show Figures

Figure 1

17 pages, 2192 KB  
Article
Short-Term Active Power Reduction in DFIG-Based Wind Farms for Improving First-Swing Stability in Power Systems
by Yuan Liu and Taishan Xu
Energies 2026, 19(8), 1873; https://doi.org/10.3390/en19081873 - 11 Apr 2026
Viewed by 369
Abstract
In this paper, a short-term active power curtailment (ST-APC) strategy for doubly-fed induction generator (DFIG) wind farms is proposed to enhance first-swing rotor angle stability under fault disturbances. While wind power is a clean renewable resource that is widely deployed, its large-scale integration [...] Read more.
In this paper, a short-term active power curtailment (ST-APC) strategy for doubly-fed induction generator (DFIG) wind farms is proposed to enhance first-swing rotor angle stability under fault disturbances. While wind power is a clean renewable resource that is widely deployed, its large-scale integration heightens concerns about transient stability. After analyzing DFIG operating principles, this study advocates for using short-horizon active power control to mitigate the adverse stability impacts of wind farms. Using the Western System Coordinating Council (WSCC) three-machine nine-bus test system, the effectiveness of the ST-APC strategy across diverse operating conditions was verified. This study is based on the fundamental principle that reducing the output of wind turbines is required for first-swing stability after faults to increase the kinetic energy of synchronous machines. A closed-loop control strategy combining voltage drop, frequency change, and a timer is designed. The correlation laws between various control parameters such as control activation timing, duration, and modulation depth and first-swing stability are analyzed, providing references for parameter selection in engineering applications. The findings indicate that the proposed strategy is practical and adaptable, making it suitable for power systems with high wind power penetration. Full article
(This article belongs to the Section A3: Wind, Wave and Tidal Energy)
Show Figures

Figure 1

23 pages, 6512 KB  
Article
High-Performance Sensorless Control of a Dual-Inverter Doubly Fed Induction Motor for Electric Vehicle Traction Using a Sliding-Mode Observer
by Mouna Zerzeri and Adel Khedher
Automation 2026, 7(1), 31; https://doi.org/10.3390/automation7010031 - 11 Feb 2026
Cited by 1 | Viewed by 713
Abstract
This paper presents a robust sensorless control strategy for a dual-inverter doubly fed induction motor (DFIM) designed for high-performance electric vehicle (EV) traction systems. The proposed scheme eliminates the mechanical speed sensor by employing a sliding-mode observer (SMO) for real-time estimation of rotor [...] Read more.
This paper presents a robust sensorless control strategy for a dual-inverter doubly fed induction motor (DFIM) designed for high-performance electric vehicle (EV) traction systems. The proposed scheme eliminates the mechanical speed sensor by employing a sliding-mode observer (SMO) for real-time estimation of rotor speed and flux, ensuring accurate feedback under load disturbances and thereby enhancing reliability while reducing implementation cost. The DFIM is powered by two voltage-source inverters that independently control the stator and rotor windings through space vector pulse-width modulation (SVPWM). A power-sharing strategy optimally distributes the electromagnetic power between the two converters, ensuring smooth transitions between sub-synchronous and super-synchronous operating modes. Furthermore, a stator-flux-oriented vector control (SFOC) scheme incorporating a graphical torque optimization algorithm is developed to maximize torque while satisfying inverter and machine constraints across both base-speed and flux-weakening regions. The stability of the SMO-based estimation and closed-loop control is rigorously validated using Lyapunov theory. Comprehensive MATLAB R2024b/Simulink simulations conducted under the WLTC-Class 3 driving cycle confirm high accuracy and robustness, showing fast dynamic response, precise speed estimation, and smooth torque behavior across the full speed range. The results demonstrate that the SMO-based DFIM drive offers a cost-effective and reliable solution for next-generation EV traction applications. Full article
Show Figures

Figure 1

15 pages, 2797 KB  
Article
Coordinated Control of Standalone Brushless Doubly-Fed Induction Generator for Load Disturbance Suppression in Microgrid
by Wei Luo, Yan Le, Minglei Xie, Yi Liu and Dayi Li
Energies 2026, 19(2), 464; https://doi.org/10.3390/en19020464 - 17 Jan 2026
Cited by 1 | Viewed by 329
Abstract
The anti-load-disturbance capability is one of the most important capabilities in a microgrid. In comparison with the grid-connected brushless doubly-fed induction generator (BDFIG), the output voltage of the standalone BDFIG in a microgrid is more susceptible to load disturbances. In order to address [...] Read more.
The anti-load-disturbance capability is one of the most important capabilities in a microgrid. In comparison with the grid-connected brushless doubly-fed induction generator (BDFIG), the output voltage of the standalone BDFIG in a microgrid is more susceptible to load disturbances. In order to address this issue, this paper presents a coordinated control method based on both the machine side converter (MSC) and line side converter (LSC) to reduce the amplitude of power winding (PW) voltage fluctuation and shorten transient response time, so as to significantly reduce the influence of the load disturbance on the output voltage under the limited power converter capacity. The proposed control strategy is validated through experiments conducted on a 3 kW wound-rotor BDFIG. Full article
Show Figures

Figure 1

40 pages, 3419 KB  
Systematic Review
Improvement of Low Voltage Ride-Through (LVRT) of Doubly Fed Induction Generator (DFIG)-Based Wind Energy Conversion Systems (WECSs) by STATCOMs: A Systematic Literature Review
by Nhlanhla Mbuli
Energies 2026, 19(2), 443; https://doi.org/10.3390/en19020443 - 16 Jan 2026
Cited by 2 | Viewed by 697
Abstract
To maintain power system stability and supply quality when integrating doubly fed induction generator (DFIG)-based wind energy conversion systems (DFIG-WECSs), regulators regularly update grid codes specifying low voltage ride-through (LVRT) requirements. This paper presents a systematic literature review (SLR) on the use of [...] Read more.
To maintain power system stability and supply quality when integrating doubly fed induction generator (DFIG)-based wind energy conversion systems (DFIG-WECSs), regulators regularly update grid codes specifying low voltage ride-through (LVRT) requirements. This paper presents a systematic literature review (SLR) on the use of STATCOMs to enhance LVRT capability in DFIG-WECSs. Objectives included a structured literature search, bibliographic analysis, thematic synthesis, trend identification, and proposing future research directions. A PRISMA-based methodology guided the review, utilising PRISMA 2020 for Abstracts in the development of the abstract. The final search was conducted on Scopus (31 March 2025). Eligible studies were primary research in English (2009–2014) where STATCOM was central to LVRT enhancement; exclusions included non-English studies, duplicates, reviews, and studies without a STATCOM focus. Quality was assessed using an adapted Critical Appraisal Skills Programme (CASP) tool. No automation or machine learning tools were used. Thirty-eight studies met the criteria and were synthesised under four themes: operational contexts, STATCOM-based schemes, control strategies, and optimisation techniques. Unlike prior reviews, this study critically evaluates merits, limitations, and practical challenges. Trend analysis shows evolution from hardware-based fault survival strategies to advanced optimisation and coordinated control schemes, emphasising holistic grid stability and renewable integration. Identified gaps include cyber-physical security, techno-economic assessments, and multi-objective optimisation. Actionable research directions are proposed. By combining technical evaluation with systematic trend analysis, this review clarifies the state of STATCOM-assisted LVRT strategies and outlines pathways for future innovation in DFIG-WECS integration. Full article
Show Figures

Figure 1

19 pages, 14712 KB  
Article
Development and Design Optimization of a Single-Phase Doubly-Fed Flux-Switching Permanent Magnet Machine
by Lijian Wu, Usman Tahir, Wenting Wang, Haoyu Zhou, Jianglong Chen and Tao Wang
Energies 2025, 18(22), 6035; https://doi.org/10.3390/en18226035 - 19 Nov 2025
Viewed by 787
Abstract
Demand for brushless alternatives to the series universal motors and induction motors in domestic applications and automotive applications is increasing. Among the available candidates, single-phase flux-switching permanent magnet (SP-FSPM) machines have gained attention due to a simpler magnetic structure and control system. However, [...] Read more.
Demand for brushless alternatives to the series universal motors and induction motors in domestic applications and automotive applications is increasing. Among the available candidates, single-phase flux-switching permanent magnet (SP-FSPM) machines have gained attention due to a simpler magnetic structure and control system. However, their torque density remains limited. Therefore, a SP doubly-fed FSPM (SP-DF-FSPM) machine is developed in this paper which features an additional set of armature windings on the rotor. By effectively utilizing the rotor slot area, the proposed SP-DF-FSPM machine enhances electrical loading and torque density while providing inherent fault-tolerant capability, a critical addition compared with conventional SP-FSPM machines. A comprehensive parameter-sensitivity analysis is conducted for a 10-stator-pole/10-rotor-tooth configuration to optimize key geometric parameters for the maximum torque and reliable self-starting operation. The electromagnetic performance of an optimized design is evaluated and compared against a conventional SP-FSPM machine. The results show that the SP-DF-FSPM machine can achieve a 24.75% higher torque output, improved efficiency, and enhanced power factors under the healthy condition. Moreover, the machine can deliver 63.5% and 36.0% torque when operating with only stator and rotor windings, respectively, demonstrating the fault-tolerant capability. Experimental validation via an SP-DF-FSPM prototype shows close agreement with simulation results. Full article
Show Figures

Figure 1

19 pages, 2433 KB  
Article
Two-Dimensional Analytical Magnetic Field Calculation in a Brushless Doubly Fed Reluctance Machine
by Slimane Tahi, Cherif Guerroudj, Smail Mezani, Rachid Ibtiouen and Noureddine Takorabet
Actuators 2025, 14(10), 486; https://doi.org/10.3390/act14100486 - 7 Oct 2025
Viewed by 845
Abstract
This paper proposes a 2D semi-analytical model based on the subdomain method for the performance analysis of a brushless doubly fed reluctance machine (BDFRM) with a salient pole rotor. In particular, assuming an infinite magnetic permeability of the iron core and assuming a [...] Read more.
This paper proposes a 2D semi-analytical model based on the subdomain method for the performance analysis of a brushless doubly fed reluctance machine (BDFRM) with a salient pole rotor. In particular, assuming an infinite magnetic permeability of the iron core and assuming a smooth stator, the field calculation region is divided into two solution subdomains, i.e., the rotor slot and air-gap. The magnetic vector potential in each subdomain is obtained by solving the governing PDE by the separation of variables method and employing the boundary conditions between adjacent interfaces. Moreover, based on the stored magnetic energy in the air-gap, the calculation of the three-phase windings’ self and mutual inductances is presented. Through a case study involving a 6/2 pole BDFRM, the accuracy of the developed subdomain model is confirmed by comparing its analytically predicted results with those obtained from two-dimensional finite element method (FEM) simulations. Full article
(This article belongs to the Special Issue Advanced Theory and Application of Magnetic Actuators—3rd Edition)
Show Figures

Figure 1

20 pages, 9282 KB  
Article
Electromagnetic Vibration Characteristics Analysis of Large-Scale Doubly Fed Induction Machines Under Multiple Operating Conditions
by Haoyu Kang, Yiming Ma, Liyang Liu, Fanqi Huang and Libing Zhou
Machines 2025, 13(9), 777; https://doi.org/10.3390/machines13090777 - 30 Aug 2025
Viewed by 1169
Abstract
The electromagnetic vibration characteristics of doubly fed induction machines (DFIMs) employed in variable-speed pumped storage units, which must accommodate frequent power response and operational mode transitions, serve as critical indicators for assessing unit safety and stability. Nevertheless, there persists a significant research gap [...] Read more.
The electromagnetic vibration characteristics of doubly fed induction machines (DFIMs) employed in variable-speed pumped storage units, which must accommodate frequent power response and operational mode transitions, serve as critical indicators for assessing unit safety and stability. Nevertheless, there persists a significant research gap regarding generalized vibration analysis models and comprehensive investigations into their steady-state and dynamic vibration performance. To address this challenge, this study develops a universal analytical model for electromagnetic excitation forces in DFIMs using Maxwell’s stress tensor method, explicitly incorporating operational conditions such as rotor eccentricity and load imbalance. Using a 300 MW DFIM as a case study, we employ a hybrid numerical-analytical approach to examine the detrimental effects of harmonic currents generated by rotor-side converters. Furthermore, we systematically analyze how spatial harmonics induced by mechanical faults and temporal harmonics arising from electrical faults collectively influence the electromagnetic vibration behavior. Experimental validation conducted on a 10 MW DFIM prototype through vibration displacement measurements confirms the efficacy of the proposed analytical framework. Full article
Show Figures

Figure 1

26 pages, 2471 KB  
Article
Fault-Tolerant Tracking Observer-Based Controller Design for DFIG-Based Wind Turbine Affected by Stator Inter-Turn Short Circuit
by Yossra Sayahi, Moez Allouche, Mariem Ghamgui, Sandrine Moreau, Fernando Tadeo and Driss Mehdi
Symmetry 2025, 17(8), 1343; https://doi.org/10.3390/sym17081343 - 17 Aug 2025
Cited by 2 | Viewed by 1446
Abstract
This paper introduces a novel strategy for the diagnosis and fault-tolerant control (FTC) of inter-turn short-circuit (ITSC) faults in the stator windings of Doubly Fed Induction Generator (DFIG)-based wind turbines. ITSC faults are among the most common electrical issues in rotating machines: early [...] Read more.
This paper introduces a novel strategy for the diagnosis and fault-tolerant control (FTC) of inter-turn short-circuit (ITSC) faults in the stator windings of Doubly Fed Induction Generator (DFIG)-based wind turbines. ITSC faults are among the most common electrical issues in rotating machines: early detection is therefore essential to reduce maintenance costs and prevent severe damage to the wind turbine system. To address this, a Fault Detection and Diagnosis (FDD) approach is proposed to identify and assess the severity of ITSC faults in the stator windings. A state-space model of the DFIG under ITSC fault conditions is first developed in the (d,q) reference frame. Based on this model, an Unknown Input Observer (UIO) structured using Takagi–Sugeno (T-S) fuzzy models is designed to estimate the fault level. To mitigate the impact of the fault and ensure continued operation under degraded conditions, a T-S fuzzy fault-tolerant controller is synthesized. This controller enables natural decoupling and optimal power extraction across a wide range of rotor speed variations. Since the effectiveness of the FTC relies on accurate fault information, a Proportional-Integral Observer (PIO) is employed to estimate the ITSC fault level. The proposed diagnosis and compensation strategy is validated through simulations performed on a 3 kW wind turbine system, demonstrating its efficiency and robustness. Full article
(This article belongs to the Special Issue Symmetry, Fault Detection, and Diagnosis in Automatic Control Systems)
Show Figures

Figure 1

23 pages, 2768 KB  
Article
Nonlinear Algebraic Parameter Estimation of Doubly Fed Induction Machine Based on Rotor Current Falling Curves
by Alexander Glazyrin, Dmitriy Bunkov, Evgeniy Bolovin, Yusup Isaev, Vladimir Kopyrin, Sergey Kladiev, Alexander Filipas, Sergey Langraf, Rustam Khamitov, Vladimir Kovalev, Evgeny Popov, Semen Popov and Marina Deneko
Energies 2025, 18(16), 4316; https://doi.org/10.3390/en18164316 - 14 Aug 2025
Cited by 1 | Viewed by 838
Abstract
Currently, wind turbines utilize doubly fed induction machines that incorporate a frequency converter in the rotor circuit to manage slip energy. This setup ensures a stable voltage amplitude and frequency that align with the alternating current. It is crucial to accurately determine the [...] Read more.
Currently, wind turbines utilize doubly fed induction machines that incorporate a frequency converter in the rotor circuit to manage slip energy. This setup ensures a stable voltage amplitude and frequency that align with the alternating current. It is crucial to accurately determine the parameters of the equivalent circuit from the rotor side of the vector control system of the frequency converter. The objective of this study is to develop a method for the preliminary identification of the doubly fed induction machines parameters by analyzing the rotor current decay curves using Newton’s method. The numerical estimates of the equivalent circuit parameters a doubly fed induction machines with a fixed short-circuited rotor are obtained during the validation of the results on a real plant. It is along with the integral errors of deviation between the experimental rotor current decay curve and the response of the adaptive regression model. The integral errors do not exceed 4% in nearly all sections of the curves. It is considered acceptable in engineering practice. The developed algorithm for the preliminary identification for the parameters of the doubly fed induction machines substitution scheme can be applied with the configuring machines control systems, including a vector control system. Full article
Show Figures

Figure 1

24 pages, 2101 KB  
Article
Analysis on the Influence of the Active Power Recovery Rate on the Transient Stability Margin of a New Power System
by Yanxin Gu and Yibo Zhou
Processes 2025, 13(7), 2020; https://doi.org/10.3390/pr13072020 - 26 Jun 2025
Cited by 5 | Viewed by 1098
Abstract
With the large-scale integration of wind power, transient stability issues in power systems have become increasingly prominent, among which the impact of the active power recovery rate of wind turbines on system stability cannot be ignored. This paper establishes a sensitivity analytical model [...] Read more.
With the large-scale integration of wind power, transient stability issues in power systems have become increasingly prominent, among which the impact of the active power recovery rate of wind turbines on system stability cannot be ignored. This paper establishes a sensitivity analytical model between the transient stability index of the system and the active power recovery rate of doubly fed induction generators (DFIGs), revealing the influence of active power recovery rate on system stability. First, the trajectory analysis method is adopted as the transient stability assessment approach, proposing a stability index incorporating accelerating power and transient potential energy. Analytical sensitivity models for synchronous generator accelerating power and transient potential energy to the active power recovery rate of wind turbines are derived in a simplified system. Second, a sensitivity model of the stability margin index to the active power recovery rate is constructed to analyze the influence patterns of the active power recovery rate, initial active power output of wind turbines, and fault duration time on system stability. This research demonstrates that: accelerating the active power recovery rate can restore power balance more quickly but it reduces the rate of transient potential energy variation and delays the peak response of potential energy, thereby decreasing the stability margin; higher initial active power output of wind turbines suppresses the oscillation amplitude of synchronous generators but increases the risk of power imbalance; and prolonged fault duration exacerbates transient energy accumulation and significantly degrades system stability. Additionally, for each 0.1 p.u./s increase in the active power recovery rate of the wind turbine, the absolute value of the stability index of the synchronous machine in the single-machine system decreases by approximately 0.5–1.0, while the sensitivity decreases by approximately 0.01–0.02 s−1. In the multi-machine system, the absolute value of the stability index of the critical machine decreases by approximately 5–10, and the sensitivity decreases by approximately 0.5–1.0 s−1. Full article
(This article belongs to the Special Issue Smart Optimization Techniques for Microgrid Management)
Show Figures

Figure 1

18 pages, 8919 KB  
Article
Model Reference Adaptive Sensorless Control of Variable-Speed Pumped Storage Doubly Fed Induction Machine Under Reversible Operations
by Zhi Zheng, Ziqiang Man, Shuxin Tan, Wei Yan, Yu Lu, Jie Tian, Weiqun Liu and Xu Wang
Energies 2025, 18(11), 2998; https://doi.org/10.3390/en18112998 - 5 Jun 2025
Cited by 2 | Viewed by 947
Abstract
The sensorless control of doubly fed induction machine (DFIM) rotor magnetic flux based on a model reference adaptive system (MRAS) is proposed to improve the reliability of a large-scale variable-speed pumped storage (VSPS) system and reduce operation and maintenance costs. The existing sensorless [...] Read more.
The sensorless control of doubly fed induction machine (DFIM) rotor magnetic flux based on a model reference adaptive system (MRAS) is proposed to improve the reliability of a large-scale variable-speed pumped storage (VSPS) system and reduce operation and maintenance costs. The existing sensorless control of doubly fed induction machines (DFIMs) is mostly focused on generator operation, making it difficult to apply to the VSPS system. The proposed strategy realizes the reversible operations of the VSPS through the design of an adaptive law under variable operating conditions, eliminating mechanical sensors, and possessing the characteristics of simple implementation and accurate identification. The mathematical model of the DFIM in a VSPS system is constructed, and an MRAS vector control strategy based on stator voltage orientation is established. The rotor angle and speed under reversible operating conditions are effectively identified by dynamically adjusting the angle error between the rotor flux reference model and the adaptive model to approach zero. Subsequently, comparative analysis with the closed-loop direct detection method verifies the advantages of the proposed strategy. The proposed control method can accurately identify rotor position and speed in the pumping and power generation conditions of the VSPS system and it demonstrates robust adaptability. Full article
Show Figures

Figure 1

28 pages, 5361 KB  
Article
Small-Disturbance Stability Analysis of Doubly Fed Variable-Speed Pumped Storage Units
by Xiangyang Yu, Yujie Cui, Hao Qi, Chunyang Gao, Ziming He and Haipeng Nan
Energies 2025, 18(11), 2796; https://doi.org/10.3390/en18112796 - 27 May 2025
Cited by 1 | Viewed by 892
Abstract
The variable-speed operation mode of pumped storage units improves the regulation performance and endows the units with characteristics such as isolation from the power grid, thereby affecting the system stability. This study establishes a detailed mathematical model for the connection of doubly fed [...] Read more.
The variable-speed operation mode of pumped storage units improves the regulation performance and endows the units with characteristics such as isolation from the power grid, thereby affecting the system stability. This study establishes a detailed mathematical model for the connection of doubly fed induction generator-based variable-speed pumped storage (DFIG-VSPS) to a single-machine infinite bus system under power generation conditions in the synchronous rotation direct-quadrature-zero coordinate system. The introduction of the eigenvalue method to analyze the small-disturbance stability of doubly fed variable-speed pumped storage units and the use of participation factors to calculate the degree of influence of each state variable on the small-disturbance stability of the units are innovations of this study. The participation factor enhances flexibility, continuity, and efficiency in doubly fed variable-speed pumped storage by optimizing dynamic power paths and enabling multi-objective control coordination. While eigenvalue analysis is not new, this study is the first to apply it with participation factors to DFIG-VSPS, addressing gaps in prior simplified models. Furthermore, based on the changes in the characteristic root trajectories, the influence of changes in the speed control system parameters and converter controller parameters on the system stability was determined. Finally, the conclusions obtained were verified through simulation. The results indicate that increasing the time constant of water flow inertia poses a risk of system instability, and the increase in proportional parameters and decrease in integral parameters of the power outer loop controller significantly affect the system stability. Full article
Show Figures

Figure 1

22 pages, 3239 KB  
Article
Analysis and Suppression Strategies of Sub-Synchronous Oscillations in DFIG Wind Farm Integrated with Synchronous Pumped Storage System
by Yuzhe Chen, Feng Wu, Linjun Shi, Yang Li, Zizhao Wang and Yanbo Ding
Sustainability 2025, 17(10), 4588; https://doi.org/10.3390/su17104588 - 16 May 2025
Cited by 5 | Viewed by 1336
Abstract
The sub-synchronous oscillation (SSO) characteristics and suppression strategies of a hybrid system comprising doubly fed induction generator (DFIG)-based wind turbines and synchronous pumped storage units connected to the power grid via series-compensated transmission lines are analyzed. A modular modeling approach is used to [...] Read more.
The sub-synchronous oscillation (SSO) characteristics and suppression strategies of a hybrid system comprising doubly fed induction generator (DFIG)-based wind turbines and synchronous pumped storage units connected to the power grid via series-compensated transmission lines are analyzed. A modular modeling approach is used to construct a detailed system model, including the wind turbine shaft system, DFIG, converter control system, synchronous machine, excitation system, power system stabilizer (PSS), and series-compensated transmission lines. Eigenvalue calculation-based small-signal stability analysis is conducted to identify the dominant oscillation modes. Suppression measures are also developed using relative participation analysis, and simulations are carried out to validate the accuracy of the model and analysis method. The analysis results indicate that the SSO phenomenon is primarily influenced by the electrical state variables of the DFIG system, while the impact of the state variables of the synchronous machine is relatively minor. When the level of series compensation in the system increases, SSO is significantly exacerbated. To address this issue, a sub-synchronous damping controller (SSDC) is incorporated on the rotor side of the DFIG. The results demonstrate that this method effectively mitigates the SSO and significantly enhances the system’s robustness against disturbances. Furthermore, a simplified modeling approach is proposed based on relative participation analysis. This method neglects the dynamic characteristics of the synchronous machine while considering its impact on the steady-state impedance and initial conditions of the model. These findings provide theoretical guidance and practical insights for addressing and mitigating SSO issues in hybrid renewable energy systems composed of DFIGs and synchronous machines. Full article
Show Figures

Figure 1

18 pages, 4726 KB  
Article
Sensorless Control of Doubly Fed Induction Machines Using Only Rotor-Side Variables
by Yongsu Han
Symmetry 2025, 17(5), 712; https://doi.org/10.3390/sym17050712 - 7 May 2025
Cited by 2 | Viewed by 977
Abstract
In this study, a sensorless vector control method was proposed for a doubly fed induction machine (DFIM), where the stator is directly connected to the grid. The DFIM is a three-phase symmetric system without saliency, and when the stator side is directly connected [...] Read more.
In this study, a sensorless vector control method was proposed for a doubly fed induction machine (DFIM), where the stator is directly connected to the grid. The DFIM is a three-phase symmetric system without saliency, and when the stator side is directly connected to the grid, the magnitude and frequency of the stator flux are almost fixed and determined by the grid voltage. Due to its three-phase symmetric configuration, this structure can be modeled in a manner similar to that of a symmetric permanent-magnet synchronous motor (PMSM). It enables the application of back-EMF-based sensorless control methods commonly used for symmetric PMSMs. In PMSMs, sensorless estimators typically estimate the back-EMF using only stator voltage and current measurements. By extending this modeling concept to DFIMs, a similar estimator can be designed that utilizes only rotor-side voltage and current for sensorless back-EMF estimation. This paper proposes a back-EMF estimator using only rotor-side voltages and currents, which were implemented on a stator flux reference frame. The proposed algorithm also estimates the stator-side variables, including the magnitudes of stator voltage, current, and stator power factor. These variables can be used to detect grid faults. The feasibility of the proposed method was validated via experiments using a 2.4 kW DFIM. It was confirmed that the sensorless operation functioned properly even during speed acceleration/deceleration and step load conditions. Additionally, the system maintained stable operation and achieved an accurate estimation of stator voltage and current, even under a 30% voltage sag in the stator grid voltage. Full article
(This article belongs to the Special Issue Applications of Symmetry Three-Phase Electrical Power Systems)
Show Figures

Figure 1

Back to TopTop