Sign in to use this feature.

Years

Between: -

Subjects

remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline

Journals

Article Types

Countries / Regions

remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline

Search Results (226)

Search Parameters:
Keywords = carbon dioxide cooling

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
16 pages, 3766 KiB  
Article
Evaluation of Energy and CO2 Reduction Through Envelope Retrofitting: A Case Study of a Public Building in South Korea Conducted Using Utility Billing Data
by Hansol Lee and Gyeong-Seok Choi
Energies 2025, 18(15), 4129; https://doi.org/10.3390/en18154129 - 4 Aug 2025
Viewed by 145
Abstract
This study empirically evaluates the energy and carbon reduction effects of an envelope retrofit applied to an aging public building in South Korea. Unlike previous studies that primarily relied on simulation-based analyses, this work fills the empirical research gap by using actual utility [...] Read more.
This study empirically evaluates the energy and carbon reduction effects of an envelope retrofit applied to an aging public building in South Korea. Unlike previous studies that primarily relied on simulation-based analyses, this work fills the empirical research gap by using actual utility billing data collected over one pre-retrofit year (2019) and two post-retrofit years (2023–2024). The retrofit included improvements to exterior walls, roofs, and windows, aiming to enhance thermal insulation and airtightness. The analysis revealed that monthly electricity consumption was reduced by 14.7% in 2023 and 8.0% in 2024 compared to that in the baseline year, with corresponding decreases in electricity costs and carbon dioxide emissions. Seasonal variations were evident: energy savings were significant in the winter due to reduced heating demand, while cooling energy use slightly increased in the summer, likely due to diminished solar heat gains resulting from improved insulation. By addressing both heating and cooling impacts, this study offers practical insights into the trade-offs of envelope retrofitting. The findings contribute to the body of knowledge by demonstrating the real-world performance of retrofit technologies and providing data-driven evidence that can inform policies and strategies for improving energy efficiency in public buildings. Full article
Show Figures

Figure 1

41 pages, 16361 KiB  
Review
Progress on Sustainable Cryogenic Machining of Hard-to-Cut Material and Greener Processing Techniques: A Combined Machinability and Sustainability Perspective
by Shafahat Ali, Said Abdallah, Salman Pervaiz and Ibrahim Deiab
Lubricants 2025, 13(8), 322; https://doi.org/10.3390/lubricants13080322 - 23 Jul 2025
Viewed by 331
Abstract
The current research trends of production engineering are based on optimizing the machining process concerning human and environmental factors. High-performance materials, such as hardened steels, nickel-based alloys, fiber-reinforced polymer (FRP) composites, and titanium alloys, are classified as hard-to-cut due to their ability to [...] Read more.
The current research trends of production engineering are based on optimizing the machining process concerning human and environmental factors. High-performance materials, such as hardened steels, nickel-based alloys, fiber-reinforced polymer (FRP) composites, and titanium alloys, are classified as hard-to-cut due to their ability to maintain strength at high operating temperatures. Due to these characteristics, such materials are employed in applications such as aerospace, marine, energy generation, and structural. The purpose of this article is to investigate the machinability of these alloys under various cutting conditions. The purpose of this article is to compare cryogenic cooling and cryogenic processing from the perspective of machinability and sustainability in the manufacturing process. Compared to conventional machining, hybrid techniques, which mix cryogenic and minimal quantity lubricant, led to significantly reduced cutting forces of 40–50%, cutting temperatures and surface finishes by approximately 20–30% and more than 40%, respectively. A carbon footprint is determined by several factors including power consumption, energy requirements, and carbon dioxide emissions. As a result of the cryogenic technology, the energy consumption, power consumption, and CO2 emissions were reduced by 40%, 28%, and 35%. Full article
Show Figures

Figure 1

17 pages, 6262 KiB  
Article
An Intelligent Thermal Management Strategy for a Data Center Prototype Based on Digital Twin Technology
by Hang Yuan, Zeyu Zhang, Duobing Yang, Tianyou Xue, Dongsheng Wen and Guice Yao
Appl. Sci. 2025, 15(14), 7675; https://doi.org/10.3390/app15147675 - 9 Jul 2025
Viewed by 334
Abstract
Data centers contribute to roughly 1% of global energy consumption and 0.3% of worldwide carbon dioxide emissions. The cooling system alone constitutes a substantial 50% of total energy consumption for data centers. Lowering Power Usage Effectiveness (PUE) of data center cooling systems from [...] Read more.
Data centers contribute to roughly 1% of global energy consumption and 0.3% of worldwide carbon dioxide emissions. The cooling system alone constitutes a substantial 50% of total energy consumption for data centers. Lowering Power Usage Effectiveness (PUE) of data center cooling systems from 2.2 to 1.4, or even below, is one of the critical issues in this thermal management area. In this work, a digital twin system of an Intelligent Data Center (IDC) prototype is designed to be capable of real-time monitoring the temperature distribution. Moreover, aiming to lower PUE, Deep Q-Learning Network (DQN) is further established to make optimization decisions of thermal management during cooling down of the local hotspot. The entire process of thermal management for IDC can be real-time visualized in Unity, forming the virtual entity of data center prototype, which provides an intelligent solution for sustainable data center operation. Full article
(This article belongs to the Special Issue Multiscale Heat and Mass Transfer and Artificial Intelligence)
Show Figures

Figure 1

18 pages, 1480 KiB  
Article
Energy-Environmental Analysis of Retrofitting of a Chilled Water Production System in an Industrial Facility—A Case Study
by Tomasz Mróz and Kacper Fórmaniak
Appl. Sci. 2025, 15(13), 7465; https://doi.org/10.3390/app15137465 - 3 Jul 2025
Viewed by 322
Abstract
This paper presents a method of evaluating energy and environmental factors before and after chilled water production system retrofitting at an industrial facility. A general algorithm was used for the analysis of chilled water system retrofitting at a pharmaceutics factory. Two retrofitting variants [...] Read more.
This paper presents a method of evaluating energy and environmental factors before and after chilled water production system retrofitting at an industrial facility. A general algorithm was used for the analysis of chilled water system retrofitting at a pharmaceutics factory. Two retrofitting variants based on dual-stage absorption chillers supplied from an existing gas-fueled co-generation plant were identified. The proposed variants, i.e., tri-generation systems, were compared with the basic variant, which relied on electric compression water chillers. An evaluation of the variants was performed on the basis of two criteria: annual primary energy consumption and annual carbon dioxide emission. Variant 2, i.e., with a 1650 kW dual-stage absorption water chiller supplied from an existing gas fueled co-generation plant, was chosen as the optimal variant. It achieved a 370 MWh annual primary energy consumption reduction and a 1140 Mg annual carbon dioxide emission reduction. It was found that increasing the co-generation ratio for the CHP plant powering the pharmaceutical factory resulted in lower consumption of primary energy in variants in which the cooling energy supply system was retrofitted based on absorption water chillers. The threshold values of the co-generation ratio were e = 0.37 for Variant 1 and e = 0.34 for Variant 2. A literature survey revealed that there is limited interest in the application of such a solution in industrial plants. The performed analysis showed that the evaluated systems may nonetheless be an attractive option for pharmaceutics factories, leading to the reduction of primary energy consumption and carbon dioxide emissions, thereby making more electrical power available for core production. The lessons learned during our analysis could be easily transferred to other industrial facilities requiring chilled water production systems. Full article
Show Figures

Figure 1

13 pages, 3038 KiB  
Article
Assessment of Global and Detailed Chemical Kinetics in Supercritical Combustion for Hydrogen Gas Turbines
by Sylwia Oleś, Jakub Mularski, Halina Pawlak-Kruczek, Abhishek K. Singh and Artur Pozarlik
Energies 2025, 18(13), 3380; https://doi.org/10.3390/en18133380 - 27 Jun 2025
Viewed by 373
Abstract
Supercritical combustion is a promising technique for improving the efficiency and reducing the emissions of next-generation gas turbines. However, accurately modeling combustion under these conditions remains a challenge, particularly due to the complexity of chemical kinetics. This study aims to evaluate the applicability [...] Read more.
Supercritical combustion is a promising technique for improving the efficiency and reducing the emissions of next-generation gas turbines. However, accurately modeling combustion under these conditions remains a challenge, particularly due to the complexity of chemical kinetics. This study aims to evaluate the applicability of a reduced global reaction mechanism compared to the detailed Foundational Fuel Chemistry Model 1.0 (FFCM-1) when performing hydrogen combustion with supercritical carbon dioxide and argon as diluents. Computational fluid dynamics simulations were conducted in two geometries: a simplified tube for isolating chemical effects and a combustor with cooling channels for practical evaluation. The analysis focuses on the evaluation of velocity, temperature, and the water vapor mass fraction distributions inside the combustion chamber. The results indicate good agreement between the global and detailed mechanisms, with average relative errors below 2% for supercritical argon and 4% for supercritical carbon dioxide. Both models captured key combustion behaviors, including buoyancy-driven flame asymmetry caused by the high density of supercritical fluids. The findings suggest that global chemistry models can serve as efficient tools for simulating supercritical combustion processes, making them valuable for the design and optimization of future supercritical gas turbine systems. Full article
(This article belongs to the Special Issue Advancements in Gas Turbine Aerothermodynamics)
Show Figures

Figure 1

21 pages, 6358 KiB  
Article
Experimental Study and Performance Analysis of a Recuperative Supercritical CO2 Brayton Cycle
by Shucheng Zhang, Juntao Ke, Min Liu, Pingjian Ming and Guopeng Yu
Energies 2025, 18(11), 2986; https://doi.org/10.3390/en18112986 - 5 Jun 2025
Viewed by 404
Abstract
To investigate the operational characteristics of the supercritical carbon dioxide (S-CO2) Brayton cycle and enhance its applicability in practical operating conditions for micro-scale reactors, an experimental platform for a recuperative S-CO2 Brayton cycle is constructed and investigated. Several controllable operational [...] Read more.
To investigate the operational characteristics of the supercritical carbon dioxide (S-CO2) Brayton cycle and enhance its applicability in practical operating conditions for micro-scale reactors, an experimental platform for a recuperative S-CO2 Brayton cycle is constructed and investigated. Several controllable operational parameters, including compressor pump frequency, expansion valve opening, and electric heating power, each intrinsically linked to the thermal characteristics of its corresponding equipment, as well as the cooling water flow rate, are systematically adjusted and analyzed. Experimental results demonstrate that the cooling water flow rate has a significantly greater impact on the temperature and pressure of the cycle system compared to other operational parameters. Based on these findings, steady-state experiments are conducted within a pressure range of 8 MPa to 15 MPa and a temperature range of 70 °C to 150 °C. It is observed that the heat exchange capacity of the recuperator decreases as the cooling water flow rate is reduced, suggesting that sufficient cooling efficiency is required to maximize the recuperative function. Under the condition of a maximum system temperature of 150 °C, the isentropic efficiency of the expansion valve decreases with an increase in the inlet pressure of the valve. However, the overall thermal efficiency of the cycle system requires further calculation and assessment following the optimization of the experimental platform. The result of validation of experimental results is less than 20%. The findings presented in this study offer essential data that encompass the potential operational conditions of the CO2 Brayton cycle section applicable to small-scale reactors, thereby providing a valuable reference for the design and operation of practical cycle systems. Full article
(This article belongs to the Special Issue Supercritical CO2 Power Cycles)
Show Figures

Figure 1

51 pages, 4396 KiB  
Review
A Review of CO2 Clathrate Hydrate Technology: From Lab-Scale Preparation to Cold Thermal Energy Storage Solutions
by Sai Bhargav Annavajjala, Noah Van Dam, Devinder Mahajan and Jan Kosny
Energies 2025, 18(10), 2659; https://doi.org/10.3390/en18102659 - 21 May 2025
Viewed by 945
Abstract
Carbon dioxide (CO2) clathrate hydrate is gaining attention as a promising material for cold thermal energy storage (CTES) due to its high energy storage capacity and low environmental footprint. It shows strong potential in building applications, where space cooling accounts for [...] Read more.
Carbon dioxide (CO2) clathrate hydrate is gaining attention as a promising material for cold thermal energy storage (CTES) due to its high energy storage capacity and low environmental footprint. It shows strong potential in building applications, where space cooling accounts for nearly 40% of total energy use and over 85% of electricity demand in developed countries. CO2 hydrates are also being explored for use in refrigeration, cold chain logistics, supercomputing, biomedical cooling, and defense systems. With the growing number of applications in mind, this review focuses on the thermal behavior of CO2 hydrates and their environmental impact. It highlights recent efforts to reduce formation pressure and temperature using chemical promoters and surfactants. This paper also reviews key experimental techniques used to study hydrate properties, including Fourier transform infrared spectroscopy (FTIR), X-ray diffraction (XRD), high-pressure differential scanning calorimetry (HP-DSC), and the T-history method. In lifecycle comparisons, CO2 hydrate systems show better energy efficiency and lower carbon emissions than traditional ice or other phase-change materials (PCMs). This review also discusses current commercialization challenges such as high energy input during formation and promoter toxicity. Finally, practical strategies to move CO2 hydrate-based CTES from lab-scale studies to real-world cooling and temperature control applications are discussed. Full article
Show Figures

Figure 1

13 pages, 2144 KiB  
Article
Enhancing Diesel Engine Performance Through Hydrogen Addition
by Sahbi Ben Abdelwahed, Fakher Hamdi, Mehrez Gassoumi, Ilham Yahya, Noomen Moussa, Nashmi H. Alrasheedi, Ridha Ennetta and Borhen Louhichi
Fire 2025, 8(5), 206; https://doi.org/10.3390/fire8050206 - 20 May 2025
Viewed by 1223
Abstract
This study evaluates the potential of hydrogen as a clean additive to conventional diesel fuel. Experiments were carried out on a single-cylinder, air-cooled diesel engine under half- and full-load conditions, across engine speeds ranging from 1000 to 3000 rpm. Hydrogen, produced on site [...] Read more.
This study evaluates the potential of hydrogen as a clean additive to conventional diesel fuel. Experiments were carried out on a single-cylinder, air-cooled diesel engine under half- and full-load conditions, across engine speeds ranging from 1000 to 3000 rpm. Hydrogen, produced on site via a proton exchange membrane electrolyser, was supplied to the engine at a constant flow rate of 0.5 L/min. Compared to pure diesel, the hydrogen–diesel blend reduced specific fuel consumption by 10% and increased brake thermal efficiency by 10% at full load. Emissions of carbon monoxide and carbon dioxide decreased by 13% and 17%, respectively, at half load. Additionally, nitrogen oxide emissions dropped by 17%. These results highlight the potential of hydrogen to improve combustion efficiency while significantly mitigating emissions, offering a viable transitional solution for cleaner power generation using existing diesel infrastructure. Full article
Show Figures

Figure 1

25 pages, 2706 KiB  
Article
Spatiotemporal Analysis of Air Pollution and Climate Change Effects on Urban Green Spaces in Bucharest Metropolis
by Maria Zoran, Dan Savastru, Marina Tautan, Daniel Tenciu and Alexandru Stanciu
Atmosphere 2025, 16(5), 553; https://doi.org/10.3390/atmos16050553 - 7 May 2025
Viewed by 739
Abstract
Being an essential issue in global climate warming, the response of urban green spaces to air pollution and climate variability because of rapid urbanization has become an increasing concern at both the local and global levels. This study explored the response of urban [...] Read more.
Being an essential issue in global climate warming, the response of urban green spaces to air pollution and climate variability because of rapid urbanization has become an increasing concern at both the local and global levels. This study explored the response of urban vegetation to air pollution and climate variability in the Bucharest metropolis in Romania from a spatiotemporal perspective during 2000–2024, with a focus on the 2020–2024 period. Through the synergy of time series in situ air pollution and climate data, and derived vegetation biophysical variables from MODIS Terra/Aqua satellite data, this study applied statistical regression, correlation, and linear trend analysis to assess linear relationships between variables and their pairwise associations. Green spaces were measured with the MODIS normalized difference vegetation index (NDVI), leaf area index (LAI), photosynthetically active radiation (FPAR), evapotranspiration (ET), and net primary production (NPP), which capture the complex characteristics of urban vegetation systems (gardens, street trees, parks, and forests), periurban forests, and agricultural areas. For both the Bucharest center (6.5 km × 6.5 km) and metropolitan (40.5 km × 40.5 km) test areas, during the five-year investigated period, this study found negative correlations of the NDVI with ground-level concentrations of particulate matter in two size fractions, PM2.5 (city center r = −0.29; p < 0.01, and metropolitan r = −0.39; p < 0.01) and PM10 (city center r = −0.58; p < 0.01, and metropolitan r = −0.56; p < 0.01), as well as between the NDVI and gaseous air pollutants (nitrogen dioxide—NO2, sulfur dioxide—SO2, and carbon monoxide—CO. Also, negative correlations between NDVI and climate parameters, air relative humidity (RH), and land surface albedo (LSA) were observed. These results show the potential of urban green to improve air quality through air pollutant deposition, retention, and alteration of vegetation health, particularly during dry seasons and hot summers. For the same period of analysis, positive correlations between the NDVI and solar surface irradiance (SI) and planetary boundary layer height (PBL) were recorded. Because of the summer season’s (June–August) increase in ground-level ozone, significant negative correlations with the NDVI (r = −0.51, p < 0.01) were found for Bucharest city center and (r = −76; p < 0.01) for the metropolitan area, which may explain the degraded or devitalized vegetation under high ozone levels. Also, during hot summer seasons in the 2020–2024 period, this research reported negative correlations between air temperature at 2 m height (TA) and the NDVI for both the Bucharest city center (r = −0.84; p < 0.01) and metropolitan scale (r = −0.90; p < 0.01), as well as negative correlations between the land surface temperature (LST) and the NDVI for Bucharest (city center r = −0.29; p< 0.01) and the metropolitan area (r = −0.68, p < 0.01). During summer seasons, positive correlations between ET and climate parameters TA (r = 0.91; p < 0.01), SI (r = 0.91; p < 0.01), relative humidity RH (r = 0.65; p < 0.01), and NDVI (r = 0.83; p < 0.01) are associated with the cooling effects of urban vegetation, showing that a higher vegetation density is associated with lower air and land surface temperatures. The negative correlation between ET and LST (r = −0.92; p < 0.01) explains the imprint of evapotranspiration in the diurnal variations of LST in contrast with TA. The decreasing trend of NPP over 24 years highlighted the feedback response of vegetation to air pollution and climate warming. For future green cities, the results of this study contribute to the development of advanced strategies for urban vegetation protection and better mitigation of air quality under an increased frequency of extreme climate events. Full article
(This article belongs to the Section Biosphere/Hydrosphere/Land–Atmosphere Interactions)
Show Figures

Figure 1

19 pages, 6091 KiB  
Article
Foaming of Bio-Based PLA/PBS/PBAT Ternary Blends with Added Nanohydroxyapatite Using Supercritical CO2: Effect of Operating Strategies on Cell Structure
by Pei-Hua Chen, Chin-Wen Chen, Tzu-Hsien Chan, Hsin-Ying Lin, Ke-Ling Tuan, Chie-Shaan Su, Jung-Chin Tsai and Feng-Huei Lin
Molecules 2025, 30(9), 2056; https://doi.org/10.3390/molecules30092056 - 5 May 2025
Viewed by 673
Abstract
This study explored the innovative foaming behavior of a novel biodegradable polymer blend consisting of polylactic acid/poly(butylene succinate)/poly(butylene adipate-co-terephthalate) (PLA/PBS/PBAT) enhanced with nanohydroxyapatite (nHA), using supercritical carbon dioxide (SCCO2) as an environmentally friendly physical foaming agent. The aim was to investigate [...] Read more.
This study explored the innovative foaming behavior of a novel biodegradable polymer blend consisting of polylactic acid/poly(butylene succinate)/poly(butylene adipate-co-terephthalate) (PLA/PBS/PBAT) enhanced with nanohydroxyapatite (nHA), using supercritical carbon dioxide (SCCO2) as an environmentally friendly physical foaming agent. The aim was to investigate the effects of various foaming strategies on the resulting cell structure, aiming for potential applications in tissue engineering. Eight foaming strategies were examined, starting with a basic saturation process at high temperature and pressure, followed by rapid decompression to ambient conditions, referred to as the (1T-1P) strategy. Intermediate temperature and pressure variations were introduced before the final decompression to evaluate the impact of operating parameters further. These strategies included intermediate-temperature cooling (2T-1P), intermediate-temperature cooling with rapid intermediate decompression (2T-2P), and intermediate-temperature cooling with gradual intermediate decompression (2T-2P, stepwise ΔP). SEM imaging revealed that the (2T-2P, stepwise ΔP) strategy produced a bimodal cell structure featuring small cells ranging from 105 to 164 μm and large cells between 476 and 889 μm. This study demonstrated that cell size was influenced by the regulation of intermediate pressure reduction and the change in intermediate temperature. The results were interpreted based on classical nucleation theory, the gas solubility principle, and the effect of polymer melt strength. Foaming results of average cell size, cell density, expansion ratio, porosity, and opening cell content are reported. The hydrophilicity of various foamed polymer blends was evaluated by measuring the water contact angle. Typical compressive stress–strain curves obtained using DMA showed a consistent trend reflecting the effect of foam stiffness. Full article
Show Figures

Graphical abstract

25 pages, 6081 KiB  
Article
Predicting Thermal Conductivity of Nanoparticle-Doped Cutting Fluid Oils Using Feedforward Artificial Neural Networks (FFANN)
by Beytullah Erdoğan, Abdulsamed Güneş, İrfan Kılıç and Orhan Yaman
Micromachines 2025, 16(5), 504; https://doi.org/10.3390/mi16050504 - 26 Apr 2025
Viewed by 595
Abstract
Machining processes often face challenges such as elevated temperatures and wear, which traditional cutting fluids are insufficient to address. As a result, solutions involving nanoparticle additives are being explored to enhance cooling and lubrication performance. This study investigates the effect of thermal conductivity, [...] Read more.
Machining processes often face challenges such as elevated temperatures and wear, which traditional cutting fluids are insufficient to address. As a result, solutions involving nanoparticle additives are being explored to enhance cooling and lubrication performance. This study investigates the effect of thermal conductivity, an important property influenced by the densities of mono and hybrid nanofluids. To this end, various nanofluids were prepared by incorporating hexagonal boron nitride (hBN), zinc oxide (ZnO), multi-walled carbon nanotubes (MWCNTs), titanium dioxide (TiO2), and aluminum oxide (Al2O3) nanoparticles into sunflower oil as the base fluid. Hybrid nanofluids were created by combining two nanoparticles, including ZnO + MWCNT, hBN + MWCNT, hBN + ZnO, hBN + TiO2, hBN + Al2O3, and TiO2 + Al2O3. A dataset consisting of 180 data points was generated by measuring the thermal conductivity and density of the prepared nanofluids at various temperatures (30–70 °C) in a laboratory setting. Conducting thermal conductivity measurements across different temperature ranges presents significant challenges, requiring considerable time and resources, and often resulting in high costs and potential inaccuracies. To address these issues, a feedforward artificial neural network (FFANN) method was proposed to predict thermal conductivity. Our multilayer FFANN model takes as input the temperature of the experimental environment where the measurement is made, the measured thermal conductivity of the relevant nanoparticle, and the relative density of the nanoparticle. The FFANN model predicts the thermal conductivity value linearly as output. The model demonstrated high predictive accuracy, with a reliability of R = 0.99628 and a coefficient of determination (R2) of 0.9999. The average mean absolute error (MAE) for all hybrid nanofluids was 0.001, and the mean squared error (MSE) was 1.76 × 10−6. The proposed FFANN model provides a State-of-the-Art approach for predicting thermal conductivity, offering valuable insights into selecting optimal hybrid nanofluids based on thermal conductivity values and nanoparticle density. Full article
Show Figures

Graphical abstract

18 pages, 5134 KiB  
Article
Sustainable Hybrid Cooling: Integrating Indirect Evaporative and Split Air Conditioning for Improved Indoor Air Quality in Tropical Climates
by Tassanu Ruangsuwan, Wantanee Phanprasit, Witaya Yoosook, Vorakamol Boonyayothin, Pajaree Konthonbut, John W. Cherrie and Noppanun Nankongnab
Buildings 2025, 15(8), 1313; https://doi.org/10.3390/buildings15081313 - 16 Apr 2025
Viewed by 754
Abstract
To address the limitations of conventional split air conditioners (SACs) that lack proper ventilation, resulting in indoor pollutant buildup and health risks, this study develops and evaluates the performance of a sustainable hybrid air conditioning system that integrates Indirect Evaporative Cooling (IEC) with [...] Read more.
To address the limitations of conventional split air conditioners (SACs) that lack proper ventilation, resulting in indoor pollutant buildup and health risks, this study develops and evaluates the performance of a sustainable hybrid air conditioning system that integrates Indirect Evaporative Cooling (IEC) with SAC to enhance indoor air quality (IAQ), thermal comfort, and energy efficiency in tropical climates, compared with a standalone SAC system. The hybrid SAC + IEC system is designed to meet stringent comfort criteria while reducing indoor formaldehyde and carbon dioxide concentrations. Experiments were conducted in a controlled classroom environment using a cross-flow tubular heat exchanger with optimized nozzle configurations. Temperature, humidity, and pollutant levels were continuously monitored under varying tropical conditions. The IEC achieved an average cooling capacity of 1430 W, substantially exceeding the target of 566 W, and reduced the fresh air dry-bulb temperature by up to 8.79 °C, maintaining primary air near 25.2 °C, with energy efficiency ratios varying between 30% and 100%. The hybrid SAC + IEC system outperforms the standalone SAC system in maintaining acceptable formaldehyde and CO2 levels while delivering comfortable thermal conditions within the indoor standards. These results demonstrate that the Hybrid SAC + IEC system optimizes energy efficiency and improves cooling performance and indoor air quality (IAQ) for tropical environments. Full article
(This article belongs to the Section Building Energy, Physics, Environment, and Systems)
Show Figures

Figure 1

26 pages, 6323 KiB  
Article
Thermodynamic-Environmental-Economic Evaluations of a Solar-Driven Supercritical CO2 Cycle Integrated with Cooling, Heating, and Power Generation
by Shuang Yang, Xiaohe Wang, Dang Ma, Xin Shen and Xinjie Zhu
Energies 2025, 18(8), 1995; https://doi.org/10.3390/en18081995 - 13 Apr 2025
Viewed by 380
Abstract
The combined cooling, heating, and power system is based on the principle of energy cascade utilization, which is conducive to reducing fossil energy consumption and improving the comprehensive utilization efficiency of energy. With the characteristics of a lower expansion ratio and larger recuperation [...] Read more.
The combined cooling, heating, and power system is based on the principle of energy cascade utilization, which is conducive to reducing fossil energy consumption and improving the comprehensive utilization efficiency of energy. With the characteristics of a lower expansion ratio and larger recuperation of a supercritical carbon dioxide (SCO2) power cycle, a combined cooling, heating, and power (CCHP) system is proposed. The system is based on a SCO2 cycle and is driven by solar energy. The system is located in Qingdao and simulated by MATLAB/Simulink software (R2022b). Firstly, the thermodynamic performance of the CCHP system at the design condition is analyzed. The energy utilization efficiency of the CCHP system is 79.75%, and the exergy efficiency is 58.63%. Then, the thermodynamic, environmental, and economic performance analyses of the system under variable conditions are carried out. Finally, the solar multiple is optimized. The results show that the minimum levelized cost of electricity is 10.4 ¢/(kW·h), while the solar multiple is 4.8. The annual primary energy saving rate of the CCHP system is 85.04%, and the pollutant emission reduction rate is 86.05%, compared with the reference system. Therefore, an effective way to reduce environmental pollution and improve the utilization efficiency of solar energy is provided. Full article
(This article belongs to the Section A2: Solar Energy and Photovoltaic Systems)
Show Figures

Figure 1

11 pages, 5413 KiB  
Article
An Electrochemical Method for Alkalizing the Rotor Cooling Water of a Synchronous Condenser
by Xiaochun Chen, Wei Li, Xiantao Gu, Duyi He, Weicheng Fu, Yuxiang Gao, Yaoming Wang and Junying Yan
Processes 2025, 13(3), 742; https://doi.org/10.3390/pr13030742 - 4 Mar 2025
Cited by 1 | Viewed by 627
Abstract
Rotor cooling water is a pivotal element for the safe operation of a synchronous condenser in an ultrahigh-voltage grid. To decrease the dissolved oxygen and carbon dioxide contents, tremendous efforts have been dedicated to regulating the solution pH and conductivity. The traditional chemical [...] Read more.
Rotor cooling water is a pivotal element for the safe operation of a synchronous condenser in an ultrahigh-voltage grid. To decrease the dissolved oxygen and carbon dioxide contents, tremendous efforts have been dedicated to regulating the solution pH and conductivity. The traditional chemical pH adjustment and resin regeneration methods for rotor cooling water alkalization have the disadvantages of high chemical consumption and high operation and maintenance costs. Here, we propose an electrochemical method for alkalizing the rotor cooling water of a synchronous condenser by taking advantage of the accelerating water dissociation feature in bipolar membranes. The experiments with carbon dioxide injected deionized water revealed that water dissociation in bipolar membrane is capable of increasing the solution pH from 4.6 to 5.6 and decreasing the conductivity from 9.5 μS/cm to less than 2.0 μS/cm. It is convenient to increase the solution pH from 6.5 to even 10.0 when real rotor cooling water is used. BP-A-BP is more competitive than BP-C-A-BP for alkalization purposes. The present study also provides a cost-effective and chemical-free technique to precisely control the water quality of the rotor cooling water in a synchronous condenser. Full article
(This article belongs to the Section Separation Processes)
Show Figures

Figure 1

20 pages, 2654 KiB  
Article
Optimization of Low-Carbon Operation in a Combined Electrical, Thermal, and Cooling Integrated Energy System with Liquid Carbon Dioxide Energy Storage and Green Certificate and Carbon Trading Mechanisms
by Xiaojing Ma, Zhiqing Zhang, Jie Chen and Ming Sun
Processes 2025, 13(2), 372; https://doi.org/10.3390/pr13020372 - 29 Jan 2025
Cited by 2 | Viewed by 990
Abstract
The liquid carbon dioxide energy storage system (LCES), as a highly flexible, long-lasting, and environmentally friendly energy storage technology, shows great potential for application in integrated energy systems. However, research on the combined cooling, heating, and power supply using LCES in integrated energy [...] Read more.
The liquid carbon dioxide energy storage system (LCES), as a highly flexible, long-lasting, and environmentally friendly energy storage technology, shows great potential for application in integrated energy systems. However, research on the combined cooling, heating, and power supply using LCES in integrated energy systems is still limited. In this paper, an optimized scheduling scheme for a low-carbon economic integrated energy system is proposed, coupling LCES with power-to-gas (P2G) technology and the green certificate/carbon trading mechanism. Mathematical models and constraints for each system component are developed, and an optimization scheduling model is constructed, focusing on the economic and low-carbon operation of the integrated energy microgrid system. The objective function aims to minimize total system costs. A case study based on a northern China park is conducted, with seven scenarios set for comparative optimization analysis. The results demonstrate that the use of the combined cooling, heating, and power LCES system reduces total costs by USD 2,706.85 and carbon emissions by 34.57% compared to the single-energy flow operation. These findings validate the effectiveness of the proposed model in optimizing system costs and reducing carbon emissions. Full article
(This article belongs to the Section Energy Systems)
Show Figures

Figure 1

Back to TopTop