Sign in to use this feature.

Years

Between: -

Article Types

Countries / Regions

remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline

Search Results (215)

Search Parameters:
Journal = Optics

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
17 pages, 1980 KiB  
Review
Functional Optical Balance in Cataract Surgery: A Review
by Dillan Cunha Amaral, Pedro Lucas Machado Magalhães, Alex Gonçalves Sá, Alexandre Batista da Costa Neto, Flávio Moura Travassos de Medeiros, Milton Ruiz Alves, Jaime Guedes and Ricardo Noguera Louzada
Optics 2025, 6(3), 36; https://doi.org/10.3390/opt6030036 - 8 Aug 2025
Viewed by 262
Abstract
Functional Optical Balance (FOB) is a novel personalized strategy for intraocular lens (IOL) selection in cataract surgery, designed to reconcile the trade-off between optical quality and spectacle independence. FOB is a core concept aiming to maximize visual performance by treating the two eyes [...] Read more.
Functional Optical Balance (FOB) is a novel personalized strategy for intraocular lens (IOL) selection in cataract surgery, designed to reconcile the trade-off between optical quality and spectacle independence. FOB is a core concept aiming to maximize visual performance by treating the two eyes as a synergistic pair. One eye (often the dominant eye) is optimized for pristine optical quality (typically distance vision with a high-contrast monofocal or low-add IOL). In contrast, the fellow eye is optimized for extended depth of focus and pseudoaccommodation (using an extended depth-of-focus or multifocal/trifocal IOL) to reduce dependence on glasses. This review introduces the rationale and theoretical basis for FOB, including the interplay of depth of focus and optical aberrations, binocular summation, ocular dominance, and neuroadaptation. We discuss the clinical implementation of FOB: how the first-eye results guide the second-eye IOL choice in a tailored “mix-and-match” approach, as well as practical workflow considerations such as patient selection, ocular measurements, and decision algorithms. We also review current evidence from the literature on asymmetric IOL combinations (e.g., monofocal plus multifocal, or EDOF plus trifocal), highlighting visual outcomes, patient satisfaction, and remaining evidence gaps. Overall, FOB represents a paradigm shift toward binocular, patient-customized refractive planning. Early clinical reports suggest it can deliver a continuous range of vision without significantly compromising visual quality, though careful patient counseling and case selection are essential. Future directions include the integration of advanced diagnostics, artificial intelligence-driven IOL planning tools, and adaptive optics simulations to refine this personalized approach further. The promise of FOB is to improve cataract surgery outcomes by achieving an optimal balance: one that provides each patient with excellent visual quality and functional vision across distances, tailored to their lifestyle and expectations. Full article
Show Figures

Figure 1

16 pages, 3834 KiB  
Article
Deep Learning Tongue Cancer Detection Method Based on Mueller Matrix Microscopy Imaging
by Hanyue Wei, Yingying Luo, Feiya Ma and Liyong Ren
Optics 2025, 6(3), 35; https://doi.org/10.3390/opt6030035 - 4 Aug 2025
Viewed by 278
Abstract
Tongue cancer, the most aggressive subtype of oral cancer, presents critical challenges due to the limited number of specialists available and the time-consuming nature of conventional histopathological diagnosis. To address these issues, we developed an intelligent diagnostic system integrating Mueller matrix microscopy with [...] Read more.
Tongue cancer, the most aggressive subtype of oral cancer, presents critical challenges due to the limited number of specialists available and the time-consuming nature of conventional histopathological diagnosis. To address these issues, we developed an intelligent diagnostic system integrating Mueller matrix microscopy with deep learning to enhance diagnostic accuracy and efficiency. Through Mueller matrix polar decomposition and transformation, micro-polarization feature parameter images were extracted from tongue cancer tissues, and purity parameter images were generated by calculating the purity of the Mueller matrices. A multi-stage feature dataset of Mueller matrix parameter images was constructed using histopathological samples of tongue cancer tissues with varying stages. Based on this dataset, the clinical potential of Mueller matrix microscopy was preliminarily validated for histopathological diagnosis of tongue cancer. Four mainstream medical image classification networks—AlexNet, ResNet50, DenseNet121 and VGGNet16—were employed to quantitatively evaluate the classification performance for tongue cancer stages. DenseNet121 achieved the highest classification accuracy of 98.48%, demonstrating its potential as a robust framework for rapid and accurate intelligent diagnosis of tongue cancer. Full article
Show Figures

Figure 1

21 pages, 3942 KiB  
Article
Experimental Demonstration of Terahertz-Wave Signal Generation for 6G Communication Systems
by Yazan Alkhlefat, Amr M. Ragheb, Maged A. Esmail, Sevia M. Idrus, Farabi M. Iqbal and Saleh A. Alshebeili
Optics 2025, 6(3), 34; https://doi.org/10.3390/opt6030034 - 28 Jul 2025
Viewed by 537
Abstract
Terahertz (THz) frequencies, spanning from 0.1 to 1 THz, are poised to play a pivotal role in the development of future 6G wireless communication systems. These systems aim to utilize photonic technologies to enable ultra-high data rates—on the order of terabits per second—while [...] Read more.
Terahertz (THz) frequencies, spanning from 0.1 to 1 THz, are poised to play a pivotal role in the development of future 6G wireless communication systems. These systems aim to utilize photonic technologies to enable ultra-high data rates—on the order of terabits per second—while maintaining low latency and high efficiency. In this work, we present a novel photonic method for generating sub-THz vector signals within the THz band, employing a semiconductor optical amplifier (SOA) and phase modulator (PM) to create an optical frequency comb, combined with in-phase and quadrature (IQ) modulation techniques. We demonstrate, both through simulation and experimental setup, the generation and successful transmission of a 0.1 THz vector. The process involves driving the PM with a 12.5 GHz radio frequency signal to produce the optical comb; then, heterodyne beating in a uni-traveling carrier photodiode (UTC-PD) generates the 0.1 THz radio frequency signal. This signal is transmitted over distances of up to 30 km using single-mode fiber. The resulting 0.1 THz electrical vector signal, modulated with quadrature phase shift keying (QPSK), achieves a bit error ratio (BER) below the hard-decision forward error correction (HD-FEC) threshold of 3.8 × 103. To the best of our knowledge, this is the first experimental demonstration of a 0.1 THz photonic vector THz wave based on an SOA and a simple PM-driven optical frequency comb. Full article
(This article belongs to the Section Photonics and Optical Communications)
Show Figures

Figure 1

10 pages, 1762 KiB  
Article
Optical Characterization of the Interplay Between Carrier Localization and Carrier Injection in Self-Assembled GaSb/GaAs Quantum Dots
by Si-Yuan Ma, Ying Wang, Yuriy I. Mazur, Morgan E. Ware, Gregory J. Salamo and Bao Lai Liang
Optics 2025, 6(3), 33; https://doi.org/10.3390/opt6030033 - 23 Jul 2025
Viewed by 282
Abstract
The optical properties of a heterostructure containing GaSb/GaAs quantum dots (QDs) have been systematically investigated via photoluminescence (PL) measurements to gain insights into carrier dynamics. The QD and wetting layer (WL) emissions exhibit a complementary dependence on the excitation intensity and temperature, reflecting [...] Read more.
The optical properties of a heterostructure containing GaSb/GaAs quantum dots (QDs) have been systematically investigated via photoluminescence (PL) measurements to gain insights into carrier dynamics. The QD and wetting layer (WL) emissions exhibit a complementary dependence on the excitation intensity and temperature, reflecting the interplay between carrier localization in the WL and carrier relaxation from the WL to the QDs. Carrier dynamics related to localization, injection, and recombination are further validated by time-resolved photoluminescence (TRPL). These findings highlight the necessity of carefully optimizing GaSb/GaAs QD structures to mitigate the impact of carrier localization, thereby enhancing the ultimate performance of devices utilizing these QDs as active region materials. Full article
Show Figures

Graphical abstract

20 pages, 2236 KiB  
Article
Designing Quadcolor Cameras with Conventional RGB Channels to Improve the Accuracy of Spectral Reflectance and Chromaticity Estimation
by Senfar Wen and Yu-Che Wen
Optics 2025, 6(3), 32; https://doi.org/10.3390/opt6030032 - 15 Jul 2025
Viewed by 194
Abstract
Quadcolor cameras with conventional RGB channels were studied. The fourth channel was designed to improve the estimation of the spectral reflectance and chromaticity from the camera signals. The RGB channels of the quadcolor cameras considered were assumed to be the same as those [...] Read more.
Quadcolor cameras with conventional RGB channels were studied. The fourth channel was designed to improve the estimation of the spectral reflectance and chromaticity from the camera signals. The RGB channels of the quadcolor cameras considered were assumed to be the same as those of the Nikon D5100 camera. The fourth channel was assumed to be a silicon sensor with an optical filter (band-pass filter or notch filter). The optical filter was optimized to minimize a cost function consisting of the spectral reflectance error and the weighted chromaticity error, where the weighting factor controls the contribution of the chromaticity error. The study found that using a notch filter is more effective than a band-pass filter in reducing both the mean reflectance error and the chromaticity error. The reason is that the notch filter (1) improves the fit of the quadcolor camera sensitivities to the color matching functions and (2) provides sensitivity in the wavelength region where the sensitivities of RGB channels are small. Munsell color chips under illuminant D65 were used as samples. Compared with the case without the filter, the mean spectral reflectance rms error and the mean color difference (ΔE00) using the quadcolor camera with the optimized notch filter reduced from 0.00928 and 0.3062 to 0.0078 and 0.2085, respectively; compared with the case of using the D5100 camera, these two mean metrics reduced by 56.3%. Full article
Show Figures

Figure 1

9 pages, 1767 KiB  
Article
Nondestructive Hardness Assessment of Chemically Strengthened Glass
by Geovana Lira Santana, Raphael Barbosa, Vinicius Tribuzi, Filippo Ghiglieno, Edgar Dutra Zanotto, Lino Misoguti and Paulo Henrique Dias Ferreira
Optics 2025, 6(3), 31; https://doi.org/10.3390/opt6030031 - 15 Jul 2025
Viewed by 261
Abstract
Chemically strengthened glass is widely used for its remarkable fracture strength, mechanical performance, and scratch resistance. Assessing its hardness is crucial to evaluating improvements from chemical tempering. However, conventional methods like Vickers hardness tests are destructive, altering the sample surface. This study presents [...] Read more.
Chemically strengthened glass is widely used for its remarkable fracture strength, mechanical performance, and scratch resistance. Assessing its hardness is crucial to evaluating improvements from chemical tempering. However, conventional methods like Vickers hardness tests are destructive, altering the sample surface. This study presents a novel, rapid, and nondestructive testing (NDT) approach by correlating the nonlinear refractive index (n2) with surface hardness. Using ultrafast laser pulses, we measured the n2 cross-section via the nonlinear ellipse rotation (NER) signal in Gorilla®-type glass subjected to ion exchange (Na+ by K+). A microscope objective lens provided a penetration resolution of ≈5.5 μm, enabling a localized NER signal analysis. We demonstrate a correlation between the NER signal and hardness, offering a promising pathway for advanced, noninvasive characterization. This approach provides a reliable alternative to traditional destructive techniques, with potential applications in industrial quality control and material science research. Full article
Show Figures

Figure 1

34 pages, 3259 KiB  
Article
Controlled Detection for Micro- and Nanoplastic Spectroscopy/Photometry Integration Using Infrared Radiation
by Samuel Nlend, Sune Von Solms and Johann Meyer
Optics 2025, 6(3), 30; https://doi.org/10.3390/opt6030030 - 14 Jul 2025
Viewed by 168
Abstract
This paper suggests a perspective-controlled solution for an integrated Infrared micro-/nanoplastic spectroscopy/photometry-based detection, from the diffraction up to the geometry etendue, with the aim of yielding a universal spectrometer/photometer. Spectrophotometry, unlike spectroscopy that shows the interaction between matter and radiated energy, is a [...] Read more.
This paper suggests a perspective-controlled solution for an integrated Infrared micro-/nanoplastic spectroscopy/photometry-based detection, from the diffraction up to the geometry etendue, with the aim of yielding a universal spectrometer/photometer. Spectrophotometry, unlike spectroscopy that shows the interaction between matter and radiated energy, is a specific form of photometry that measures light parameters in a particular range as a function of wavelength. The solution, meant for diffraction grating and geometry etendue of the display unit, is provided by a controller that tunes the grating pitch to accommodate any emitted/transmitted wavelength from a sample made of microplastics, their degraded forms and their potential retention, and ensures that all the diffracted wavelengths are concentrated on the required etendue. The purpose is not only to go below the current Infrared limit of 20μm microplastic size, or to suggest an Infrared spectrophotometry geometry capable of detecting micro- and nanoplastics in the range of (1nm20μm) for integrated nano- and micro-scales, but also to transform most of the pivotal components to be directly wavelength-independent. The related controlled geometry solutions, from the controlled grating slit-width up to the controlled display unit etendue functions, are suggested for a wider generic range integration. The results from image-size characterization show that the following charge-coupled devices, nanopixel CCDs, and/or micropixel CCDs of less than 100nm are required on the display unit, justifying the Infrared micro- and nanoplastic-integrated spectrophotometry, and the investigation conducted with other electromagnetic spectrum ranges that suggests a possible universal spectrometer/photometer. Full article
Show Figures

Figure 1

12 pages, 483 KiB  
Article
Effect of Localized Surface Plasmons on the Nonlinear Optical Properties in the Semi-Parabolic Quantum Well
by Shusen Chen and Kangxian Guo
Optics 2025, 6(3), 29; https://doi.org/10.3390/opt6030029 - 2 Jul 2025
Viewed by 327
Abstract
In this paper, the effects of localized surface plasmons on the nonlinear optical properties of a composite system are studied. The system operates by placing a metal nanoparticle next to a semi-parabolic quantum well under a terahertz laser field. Firstly, the energy expression [...] Read more.
In this paper, the effects of localized surface plasmons on the nonlinear optical properties of a composite system are studied. The system operates by placing a metal nanoparticle next to a semi-parabolic quantum well under a terahertz laser field. Firstly, the energy expression of the semi-parabolic well in the terahertz laser field is derived via a Kramers–Henneberger transformation, and then the new energy levels and wave functions are solved by the finite difference method. Next, optical absorption coefficients and refraction index changes are derived according to quantum theory. Finally, the study shows that localized surface plasmons can cause a redshift in the peak position, while simultaneously weakening the peak value of optical absorption coefficients. The results confirm that the desired performance can be obtained by adjusting the radius of the particle, the distance between the particle and the quantum well, or the natural frequency of the quantum well. Full article
Show Figures

Figure 1

8 pages, 759 KiB  
Article
Impact of Portable Radiometers on Irradiance Measurements of LED Photocuring Units
by Matías Mederos, Guillermo Grazioli, Elisa de León Cáceres, Andrés García, José Alejandro Rivera-Gonzaga, Rim Bourgi and Carlos Enrique Cuevas-Suárez
Optics 2025, 6(3), 28; https://doi.org/10.3390/opt6030028 - 30 Jun 2025
Viewed by 291
Abstract
Purpose: The aim of this in vitro study was to evaluate the influence of different models of commercially available portable dental radiometers on the measurement of light irradiance emitted by light-emitting diode (LED) photocuring units. Materials and Methods: Eight LED photocuring units, all [...] Read more.
Purpose: The aim of this in vitro study was to evaluate the influence of different models of commercially available portable dental radiometers on the measurement of light irradiance emitted by light-emitting diode (LED) photocuring units. Materials and Methods: Eight LED photocuring units, all emitting light in a single-wavelength spectrum, were tested. Light irradiance (mW/cm2) was measured using six portable dental radiometers: four digital models (D1–D4) and two analog models (A1, A2). Digital model D1 was used as the reference (control). All measurements were conducted under standardized conditions, and each LED–radiometer combination was tested in triplicate. Data were analyzed using Sigma Plot 12.0 (Palo Alto, CA, USA) to verify the assumptions of normality and homogeneity of variances. A one-way analysis of variance (ANOVA) was used to assess the effect of the radiometer model on irradiance values, followed by Tukey’s post hoc test for multiple comparisons. The significance level was set at α < 0.05. Results: No statistically significant difference in irradiance was found between D1 (control) and D2. However, significantly lower values were recorded with A2, while D3, D4, and A1 produced significantly higher irradiance values compared to the control (p < 0.05). Conclusion: Irradiance measurements can vary significantly depending on the radiometer model used. Clinicians should be aware of this variability and are encouraged to regularly check the irradiance of the light-curing units used in daily practice, ensure their proper maintenance, and implement periodic monitoring to maintain effective clinical performance. Full article
(This article belongs to the Special Issue Advanced Optical Imaging for Biomedicine)
Show Figures

Figure 1

11 pages, 430 KiB  
Article
Experimental Observation of Laser Planar Trapping
by Silvânia A. Carvalho and Stefano De Leo
Optics 2025, 6(2), 27; https://doi.org/10.3390/opt6020027 - 18 Jun 2025
Viewed by 248
Abstract
This study experimentally demonstrates transverse symmetry breaking—a mechanism governing laser planar trapping—and distinguishes its unique role from related phenomena such as the lateral Goos–Hänchen shift and angular deviations. While the latter effects describe positional or angular beam displacements at interfaces, transverse symmetry breaking [...] Read more.
This study experimentally demonstrates transverse symmetry breaking—a mechanism governing laser planar trapping—and distinguishes its unique role from related phenomena such as the lateral Goos–Hänchen shift and angular deviations. While the latter effects describe positional or angular beam displacements at interfaces, transverse symmetry breaking fundamentally alters the beam’s spatial symmetry, enabling unprecedented control over its intensity and phase profiles. Empirical results exhibit exceptional agreement with a recently proposed theoretical model, validating its predictive capability. Crucially, our findings highlight transverse symmetry breaking as a critical tool for tailoring beam profiles, advancing applications in optical trapping, structured light systems, and photonic device engineering, where symmetry manipulation unlocks new degrees of freedom in light–matter interactions. Full article
(This article belongs to the Section Laser Sciences and Technology)
Show Figures

Figure 1

15 pages, 7516 KiB  
Article
Correction of Error Interference Fringes Based on Automatic Spectral Analysis
by Siqian Yang, Xinqiang Wang, Tingli Song, Wei Xiong, Song Ye and Fangyuan Wang
Optics 2025, 6(2), 26; https://doi.org/10.3390/opt6020026 - 6 Jun 2025
Viewed by 587
Abstract
When interferograms in space heterodyne spectrometers exhibit tilted or distorted fringes, significant errors may occur in the demodulated spectral information. To address this issue, we propose a method for interferogram correction based on automatic spectral analysis. Simulations on erroneous interferograms of monochromatic and [...] Read more.
When interferograms in space heterodyne spectrometers exhibit tilted or distorted fringes, significant errors may occur in the demodulated spectral information. To address this issue, we propose a method for interferogram correction based on automatic spectral analysis. Simulations on erroneous interferograms of monochromatic and polychromatic light demonstrate that this method effectively corrects fringe tilts and significantly improves spectral demodulation accuracy. The standard deviations between the corrected spectra and ideal spectra for monochromatic and polychromatic light are 0.016 and 0.019, respectively, compared to 0.104 and 0.127 for uncorrected spectra. Additionally, the method successfully corrects experimental interferograms of potassium and neon lamps, accurately demodulating characteristic peaks of potassium and neon emission lines. It also enables accurate displacement measurement in a Michelson interferometer experiment. This method, through automatic analysis and one-sided spectral correction, efficiently and accurately corrects erroneous interferograms and enhances spectral demodulation accuracy, showing broad application potential. Full article
Show Figures

Figure 1

15 pages, 1130 KiB  
Article
Hong–Ou–Mandel Interference on an Acousto-Optical Beam Splitter
by Piotr Kwiek
Optics 2025, 6(2), 25; https://doi.org/10.3390/opt6020025 - 5 Jun 2025
Viewed by 465
Abstract
This paper presents the results of theoretical and experimental investigations of a Hong–Ou–Mandel interferometer in which an optical beam splitter is replaced by an ultrasonic wave. The ultrasonic wave acts as an acousto-optical beam splitter for light, which is based on the phenomenon [...] Read more.
This paper presents the results of theoretical and experimental investigations of a Hong–Ou–Mandel interferometer in which an optical beam splitter is replaced by an ultrasonic wave. The ultrasonic wave acts as an acousto-optical beam splitter for light, which is based on the phenomenon of Bragg diffraction on an ultrasonic wave. The Doppler effect was considered in the theoretical considerations and confirmed experimentally. It has been shown theoretically and experimentally that the Doppler effect changes the frequency of two-photon states at the outputs of an acousto-optical beam splitter. The frequency of the two-photon state in the positive diffraction order is increased by the frequency of the ultrasonic wave, whereas in the negative diffraction order, it is reduced by the frequency of the ultrasonic wave. It should be emphasized that there are no states 1112 in the outputs (diffraction orders), which disappear as a result of Hong–Ou–Mandel interference; consequently, the probability of detecting coincidences of photons between the plus first and minus first diffraction orders is zero, as it occurs in the Hong–Ou–Mandel interferometer. The frequency difference between the two-photon states at the outputs of the acousto-optical beam splitter was confirmed by recording the two-photon beat phenomenon. The obtained results changed the current view that the Doppler effect caused by ultrasonic waves can be neglected in the interaction of correlated pairs of photons with ultrasonic waves. Full article
Show Figures

Figure 1

9 pages, 823 KiB  
Communication
Simulating Higher-Dimensional Quantum Communications Using Principal Modes
by Daniel A. Nolan
Optics 2025, 6(2), 24; https://doi.org/10.3390/opt6020024 - 4 Jun 2025
Viewed by 502
Abstract
Higher-dimensional communications in optical fiber enables new possibilities, including increased transmission capacity and hyper-entangled state transfer. However, mode coupling between channels during transmission causes interference between channels and limits detection. In classical optical communications, MIMO (modes in modes out) is a means to [...] Read more.
Higher-dimensional communications in optical fiber enables new possibilities, including increased transmission capacity and hyper-entangled state transfer. However, mode coupling between channels during transmission causes interference between channels and limits detection. In classical optical communications, MIMO (modes in modes out) is a means to deal with this issue; however, it is not possible to utilize this technology in quantum communications due to power limitations. Principal mode transmission is another means to deal with mode coupling and signal interference between channels. Conceptually, this can be used in quantum communications with some limitations. In this study, we numerically simulated this process using the time delay method and show how it can be implemented using two and four higher-dimensional quantum states, such as W or GHZ states. These numerical simulations are very illustrative of how the implementation proceeds. Full article
Show Figures

Figure 1

16 pages, 2271 KiB  
Article
Foucault–Barker Mask: Nonconventional Schlieren Technique
by Cristina M. Gómez-Sarabia and Jorge Ojeda-Castañeda
Optics 2025, 6(2), 23; https://doi.org/10.3390/opt6020023 - 4 Jun 2025
Viewed by 390
Abstract
We present a theoretical framework for designing optical masks, which are useful for implementing nonconventional Schlieren techniques. We revisit the use of effective transfer functions, which emphasize the role of symmetries in the design of coded masks. The proposed technique implements an optical [...] Read more.
We present a theoretical framework for designing optical masks, which are useful for implementing nonconventional Schlieren techniques. We revisit the use of effective transfer functions, which emphasize the role of symmetries in the design of coded masks. The proposed technique implements an optical autocorrelation of a mask, which is coded with the Barker sequences. For the same purpose, one can also use masks coded with the pseudorandom sequences. For the sake of completeness, we link our deterministic theoretical framework with a simple statistical model. The proposed technique may be useful for the automatic sensing of phase gradients. Full article
Show Figures

Figure 1

17 pages, 7486 KiB  
Article
Synthesis, Optical Properties and Photocatalytic Testing of Sol–Gel TiO2-Fe2O3/PVP Nanopowders
by Stefani Petrova, Yoanna Kostova, Martin Tsvetkov, Angelina Stoyanova, Hristina Hitkova, Polya Marinovska and Albena Bachvarova-Nedelcheva
Optics 2025, 6(2), 22; https://doi.org/10.3390/opt6020022 - 26 May 2025
Viewed by 583
Abstract
In this study, TiO2-Fe2O3/polyvinylpyrrolidone (PVP) hybrids were prepared using the sol–gel method. The iron content in the synthesized samples was 10 and 20 wt%. The influence of PVP on the phase transformation, morphology and optical properties of [...] Read more.
In this study, TiO2-Fe2O3/polyvinylpyrrolidone (PVP) hybrids were prepared using the sol–gel method. The iron content in the synthesized samples was 10 and 20 wt%. The influence of PVP on the phase transformation, morphology and optical properties of the as-prepared hybrids was characterized by various physicochemical methods—XRD analysis, UV–Vis spectroscopy, IR spectroscopy and SEM. The obtained sol–gel powders were tested for photocatalytic activity against tetracycline hydrochloride in distilled water under ultraviolet and simulated solar light illumination. The obtained results were compared to commercial TiO2 P25 (Evonik). The investigated samples exhibited good photocatalytic efficiency for the degradation of tetracycline hydrochloride; however, better activity was demonstrated by the 90TiO2-10Fe2O3/PVP sample. The latter one displayed weak antibacterial action against E. coli ATCC 25922 in the presence of UVA light. Full article
Show Figures

Figure 1

Back to TopTop