The Impact of a New “Inverted Arch” Prosthetic Annuloplasty Ring on the Mitral Valve’s 3-D Motion: An Experimental Ex-Vivo Study

1
Department of Medical Direction of University Hospital of Novara, Corso Mazzini 18, 28100 Novara, Italy
2
Department of Cardiac Surgery, “Attikon” University Hospital, 12462 Athens, Greece
3
Department of Cardiac Surgery, University Hospital of Novara, 28100 Novara, Italy
4
Department of Experimental Surgery, University Hospital of Novara, 28100 Novara, Italy
5
Department of Physiology, University of Eastern Piedmont “Amedeo Avogadro”, 28100 Novara, Italy
*
Author to whom correspondence should be addressed.
Bioengineering 2019, 6(2), 31; https://doi.org/10.3390/bioengineering6020031
Received: 2 February 2019 / Revised: 31 March 2019 / Accepted: 4 April 2019 / Published: 8 April 2019
(This article belongs to the Special Issue Implantable Medical Devices)
This experimental study aimed to evaluate the ex-vivo three-dimensional (3-D) motion of the Inverted Arch Ring (IAR), an innovative new design concept for a flexible incomplete annuloplasty prosthesis with an incorporated stabilizing rigid arch that can be used in correcting mitral valve regurgitation. Twenty explanted porcine hearts were placed in a circulation simulation system. Ultrasonometry transducers implanted in the mitral annulus were used to measure the 3-D valvular motion during a simulated cardiac cycle. Annular distance measurements were recorded and compared in each heart before and after the implantation of the IAR prosthesis at pressures corresponding to mid-systole and mid-diastole. Distances measured in mid-systole and mid-diastole demonstrated no significant differences in annular motion or in valve areas either prior to or after IAR implantation. Therefore, the results of this study confirm the minimal effects exerted by the IAR prosthesis on the mitral valve’s 3-D motion during a simulated cardiac cycle. View Full-Text
Keywords: mitral valve annuloplasty; mitral valve repair; prosthetic mitral ring mitral valve annuloplasty; mitral valve repair; prosthetic mitral ring
Show Figures

Figure 1

MDPI and ACS Style

Caimmi, P.; Kapetanakis, E.; Beggino, C.; Vacca, G.; Grossini, E.; Stratica, F.; Sacco, R.; Capponi, A. The Impact of a New “Inverted Arch” Prosthetic Annuloplasty Ring on the Mitral Valve’s 3-D Motion: An Experimental Ex-Vivo Study. Bioengineering 2019, 6, 31.

Show more citation formats Show less citations formats
Note that from the first issue of 2016, MDPI journals use article numbers instead of page numbers. See further details here.

Article Access Map by Country/Region

1
Back to TopTop