Next Article in Journal
Study of local anesthetics. Part* 166:Conductometric determination of the critical micelle concentration of local anesthetic heptacainium chloride in aqueous electrolvte solution
Previous Article in Journal
N-(3,4-Dichlorobenzyl)azoles—Investigations Regarding Synthesis, NMR-Spectroscopy and Affinity Towards Sisma-1 and Sigma-2 Receptors
 
 
Scientia Pharmaceutica is published by MDPI from Volume 84 Issue 3 (2016). Previous articles were published by another publisher in Open Access under a CC-BY (or CC-BY-NC-ND) licence, and they are hosted by MDPI on mdpi.com as a courtesy and upon agreement with Austrian Pharmaceutical Society (Österreichische Pharmazeutische Gesellschaft, ÖPhG).
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
Article

A VALIDATED HPLC-ASSAY FOR THE DETERMINATION OF MELOXICAM IN PRESENCE OF ITS DEGRADATION PRODUCTS

by
Herbert Bartsch
,
Angelika Eiper
,
Hannelore Kopelent-Frank
* and
Jiři Procházka
Institute of Pharmaceutical Chemistry, University of Vienna A-1 090 Wien, Althanstraße 14, Austria
*
Author to whom correspondence should be addressed.
Sci. Pharm. 2004, 72(3), 213-220; https://doi.org/10.3797/scipharm.aut-04-17
Submission received: 12 July 2004 / Revised: 13 August 2004 / Accepted: 13 August 2004 / Published: 3 September 2004

Abstract

The stability of aqueous solutions of meloxicam is studied with samples of different concentrations, and in different containers. Quantitation is carried out utilizing a validated stability indicating HPLC assay with five-point calibration. Sample solutions of meloxicam of three different concentrations (2 mg ml−1; 250 µg ml−1; 40 µg ml−1) are subjected to simulated sunlight and tested for stability. A distinct correlation of the photodegradation rate with the concentration of the sample solution was found. Furthermore, the influence of size and geometry of the containers in which the solutions were exposed to light was investigated and results compared.
Keywords: meloxicam; HPLC; artificial sunlight; photostability meloxicam; HPLC; artificial sunlight; photostability

Share and Cite

MDPI and ACS Style

Bartsch, H.; Eiper, A.; Kopelent-Frank, H.; Procházka, J. A VALIDATED HPLC-ASSAY FOR THE DETERMINATION OF MELOXICAM IN PRESENCE OF ITS DEGRADATION PRODUCTS. Sci. Pharm. 2004, 72, 213-220. https://doi.org/10.3797/scipharm.aut-04-17

AMA Style

Bartsch H, Eiper A, Kopelent-Frank H, Procházka J. A VALIDATED HPLC-ASSAY FOR THE DETERMINATION OF MELOXICAM IN PRESENCE OF ITS DEGRADATION PRODUCTS. Scientia Pharmaceutica. 2004; 72(3):213-220. https://doi.org/10.3797/scipharm.aut-04-17

Chicago/Turabian Style

Bartsch, Herbert, Angelika Eiper, Hannelore Kopelent-Frank, and Jiři Procházka. 2004. "A VALIDATED HPLC-ASSAY FOR THE DETERMINATION OF MELOXICAM IN PRESENCE OF ITS DEGRADATION PRODUCTS" Scientia Pharmaceutica 72, no. 3: 213-220. https://doi.org/10.3797/scipharm.aut-04-17

APA Style

Bartsch, H., Eiper, A., Kopelent-Frank, H., & Procházka, J. (2004). A VALIDATED HPLC-ASSAY FOR THE DETERMINATION OF MELOXICAM IN PRESENCE OF ITS DEGRADATION PRODUCTS. Scientia Pharmaceutica, 72(3), 213-220. https://doi.org/10.3797/scipharm.aut-04-17

Article Metrics

Back to TopTop