1. Introduction
Endophthalmitis is a purulent vision-threatening infection of the intraocular fluids and is reported to vary by geographic location in incidence and cause, following ocular surgery or injury and rarely by hematogenous spread [
1]. The clinical outcome depends on the pathogenesis of the organism and clinical intervention. Identification and characterization of the causal pathogen from routine culture media is limited due to the early administration of broad-spectrum or prophylactic antimicrobial drugs, as well as organisms that are fastidious or slow-growing [
2]. However, a common concern with conventional testing methods is the limitation in the breadth of pathogens detected, and clinicians are often left with negative results and the persisting question of whether the condition was actually caused by an infection or just an inflammatory reaction. While direct sequencing of the 16S rRNA/ITS region can be applied on clinical specimens to detect the presence of microorganisms [
3,
4], in low pathogen loads or polymicrobial infections it is usually challenging to sort out ambiguous signals from mixed chromatograms of samples, and sequences often remain unidentified/misidentified. High-throughput sequencing (HTS) also termed as next-generation sequencing (NGS), is a novel platform with the potential to simultaneously detect and independently sequence virtually all the DNA sequences of the infectious agents present in a sample [
5,
6,
7]. However, this unbiased amplification results in a large number of reads of both host and pathogen DNA, and the complexities in detecting and interpreting millions of sequences to identify the microbe(s) of interest is considerable and challenging. Targeted HTS refers to the selective capture or amplification of specific genomic regions of interest prior to massive parallel sequencing, compared to unbiased random amplification which results in the sequencing of all the nucleic acids, including host and pathogen nucleic acids, and millions of reads need to be analyzed to identify the pathogen(s) of interest. Targeted HTS, on the other hand, provides better sensitivity and specificity along with ease of downstream analysis and a lower cost by allowing more samples to be tested in one run [
8].
To cross the divide between the conventional microbiological methods and whole-genome sequencing, a culture free platform using targeted HTS would be an excellent, less complicated approach, with a lower cost to detect pathogens for implementation in diagnostic laboratories. We have previously shown that NGS is a good tool for microbial research in endophthalmitis [
9], but the next big challenges will be the standardization and validation of procedures and bioinformatics pipeline that address the specific challenges for clinical standards, especially in culture-negative cases. HTS is more likely to become a future diagnostic tool in routine ocular microbiological laboratories. Therefore, in this study, we tested 75 vitreous fluids using the targeted HTS assay, to evaluate its feasibility in an ocular clinical setting for the diagnosis of culture-negative endophthalmitis. Finally, the scope and impact of this method to diagnose pathogens in vitreous biopsies were evaluated within a clinical context.
3. Discussion
Precise diagnosis and accurate treatment of endophthalmitis depends largely on microbiological evidence and goes a long way in preventing irreversible ocular damage. Unfortunately, the number of patients coming to our institute (being a tertiary referral center) have had previous administration of antibiotics and are often severe and difficult to diagnose, leading to an increase in culture-negative infections. We have previously reported that next-generation sequencing of vitreous samples could be used for the diagnosis of infectious endophthalmitis and concluded in our small size, that culture-negative cases are actually not devoid of microorganisms [
9]. As an extension of our earlier study, we now included mainly patients with culture-negative infections, but presumed clinically as infectious endophthalmitis, in this study for validation and its diagnostic implications. It is in the interest of patients, that ocular microbiology laboratories should always be ready to adapt new technology that complements traditional workflow for better diagnostics and HTS of vitreous samples is a step in that direction, especially in countries like ours with a tropical climate, and the etiology of infections is different from that of the west. Currently, HTS of the whole genomic DNA suffers from two major limitations, one being the lack of a reference database/software that allows reliable species identification after filtering contaminant DNA, and the second major limitation of the method is the cumbersome filtering and bioinformatics analysis involved for each sample within a clinically relevant time frame necessary for timely treatment of infections and thereby antibiotic resistance control [
10]. The proportion of human DNA that is sequenced can, however, be reduced by targeting amplicon sequencing using conserved primers, followed by library preparation [
8]. One common variation of this technology is the PCR amplification of 16S rRNA targeting the hypervariable regions (V1–V9) in the case of bacteria and the ITS2 region in the case of fungi, followed by HTS of the resulting amplicon. This would not only result in decreasing the costs significantly but also help in reduced turnaround times for implementation in clinical diagnostics.
The detection of organisms from the culturally negative vitreous of patients in this study is in the presence of clinical suspicion of infection and is the probabilistic causation of the clinical condition. This evidence is strengthened by the fact that the pathogens identified by our HTS assay were in agreement with the microorganisms that grew by conventional culture methods. Similar to our earlier study, we did detect more than one pathogen in the majority of our endophthalmitis patients, which did not grow in culture, probably due to competition, difference in rate of growth, and/or quorum sensing. The novelty of this study was the high rate of detection of fungal pathogens in 41/57 (71.9%) of our culture-negative samples (
Tables S1 and S2), which highlights the geographical location of the patients tested and the at-risk populations which are not being treated with antifungals in the event of a negative microbiological diagnosis. Since fungi are slow growers or are sequestered under the lens/capsular bag [
11], detection of these organisms become difficult, resulting in them being reported as culture-negative cases. Additional diagnostic delays might also be attributed by the scarcity of fungal endophthalmitis reported in the literature and the sub-acute nature of early infection, or the difficulty of distinguishing true infection from the occasionally observed sterile inflammation. In our study, a fungal etiology was suspected clinically in only 8/41 culture-negative cases retrospectively. Unfortunately, most outcomes of fungal endophthalmitis are poor as was seen in our study where 20/41 cases diagnosed with fungal endophthalmitis by HTS had an unfavorable outcome (VA > 20/200), likely due to the prolonged time to diagnosis and delay in the administration of appropriate treatment. Another surprising finding in our study was the detection of microbial reads in 4/70 controls tested and though we would not like to rule out the possibility of contamination in these samples, it is also possible that microbial flora in the blood could enter the eye even in non-infectious conditions when there is a break in the blood-retinal barrier. But since these patients were treated on the lines of non-infectious retinal disorders and are doing well without the use of antibiotics, we presume that these controls are not undiagnosed patients. As per institute protocol, it is not a standard practice to perform microbiology cultures on the control samples as clinically they were diagnosed and treated as non-infectious. We also could not process these controls for culture after HTS results were available as the vitreous fluids were exhausted to confirm the HTS findings. Through the counting of sequence reads and calculation of statistical significance, we could recognize that the pathogens detected in the control samples were present in very low reads and our results were otherwise consistently negative for microbial nucleic acids in all test reagents and buffers. A potential drawback of targeted HTS is the detection of microbial contaminants that could be introduced through the reagents and disposables used for processing, or the laboratory environment, which can complicate the analysis and interpretation of results. Therefore, stringent adherence to reagent and workflow quality control procedures is a critical task to maintain a testing environment that is as sterile and nucleic acid–free as possible. The use of negative controls, reagent assessments, and periodic swipe tests are needed to ensure that laboratory and sample cross-contamination are not generating false-positive results. Additionally, the laboratory must be familiar with the commonly encountered ocular flora for the vitreous fluid based on the geographic incidence. The results of this study offer great opportunities for advancing precision medicine in the clinical microbiology laboratory. In the setting of culture-negative endophthalmitis, it validates the clinical judgment by ruling in the disease and helps in administering targeted antimicrobial therapy or ruling out sterile endophthalmitis instead of starting the administration of antibiotics empirically. Additionally, with the implementation of HTS, outbreak isolates may be identified to help and guide infection control efforts and antibiotic stewardship.
A major limitation of our study is that the true relevance of these pathogens in the culture-negative cases could not be validated by real-time PCR or Sanger Sequencing of the amplicons since the samples were exhausted after routine microbiological and HTS analysis, nevertheless we have to understand the clinical setting that each of these samples were clinically suspected and presumed infectious and the probability of detecting a causative pathogen was always high. From the cost-effectiveness per se, targeted HTS may help to avert additional investigations in cases of non-responding infections and therefore, will find utility in diagnostic ocular laboratories throughout the country. To assess the clinical relevance of the identified genera in such conditions, we plan a future prospective clinical trial on samples of complex patient groups of surgical endophthalmitis alone and control groups of patients without clinical suspicion of an infection. Ongoing interactions between clinicians, ocular microbiologists, and bioinformaticians are essential to assess the clinical relevance of these newer technologies in precision medicine.
4. Materials and Methods
4.1. Ethics
This was a prospective study project approved by the L V Prasad Eye Institute-Institutional Review Board (LEC 11-16-112) on 8 November 2016, and the research protocols and study design adhered to the tenets of the Declaration of Helsinki. Informed consent was taken from each patient after recording clinical details prior to study participation.
4.2. Clinical Samples
Vitreous fluids from 75 patients diagnosed clinically with presumed infectious endophthalmitis between February 2017 and December 2017 were included in the study and all samples were subjected to routine microbiological evaluation as described earlier [
9]. All cases had clinical features suggestive of endophthalmitis including ocular pain, decreased vision, eyelid edema, conjunctival congestion, chemosis, intense AC inflammation, extensive vitreous exudates, corneal infiltrates or a lens abscess, hypopyon, vitritis, and decreased red reflex. They were all clinically diagnosed and treated on lines of endophthalmitis. In our series, we had excluded all cases which had a suspicious diagnosis or where the clinical characteristics were ambiguous.
Briefly, vitreous fluid was collected aseptically from all these cases in the operating room. A standard three port, vitrectomy was done, and a 6 mm infusion cannula was used and the vitreous was aspirated through the vitrectomy probe that was connected to the vitrectomy suction tube. The undiluted (about 0.5 mL) vitreous was collected in a 2 mL disposable syringe attached to the vacuum line of the vitreous cutter and a vacuum was created by mechanical suction. The syringe with the vitreous sample was then capped with a hypodermic needle and transported in a sterile plastic container to the microbiology laboratory of the institute. Following the vitrectomy, in all these 75 patients, an intravitreal injection of antibiotics (vancomycin 1 mg/0.1 mL and amikacin 0.4 mg/0.1 mL or ceftazidime 2.25 mg/0.1 mL) with or without intravitreal dexamethasone (400 µg/0.1 mL) for empirical coverage was administered. Based on clinical suspicion or microbiological evidence of a fungal infection, the patients were given intravitreal amphotericin B (5µg/0.1 mL) additionally along with systemic antifungals. All these patients were also given ciprofloxacin (750 mg twice daily for 6 days) as the systemic antibiotic along with topical ciprofloxacin, atropine, and prednisolone acetate eye drops.
For the control group, 70 patients undergoing vitrectomy for other retinal disorders (retinal detachment, or macular hole or diabetic retinopathy), that had consented for vitreous tap done during the procedure, during the same period were included.
4.3. PCR Amplification, Illumina HiSeq Sequencing, and NGS Library Preparation
DNA was extracted from the fluids using the QIAamp DNA minikit (Qiagen, Germany), followed by PCR amplification using the V3-V4 hypervariable region of the16S rRNA gene for bacteria [
3], and internal transcribed spacer region (ITS2) of the ribosomal small subunit RNA for fungus [
4], before purification and sequencing as described earlier [
9].
4.4. Taxonomic Analysis by NGS
Raw paired-end reads of individual samples were assembled using the FLASH program and filtered to remove low quality reads (average Phred score <30) and chimeric sequences using Prinseq-lite and Usearch61, respectively. The quality reads were then subjected to the open reference operational taxonomic unit (OTU) picking using the QIIME (Quantitative Insights into Microbial Ecology) pipeline [
12] with Greengenes (V 13.8) and Unite (V 12.11) OTUs clustered at 97% sequence similarity for bacterial and fungal identification, respectively. Taxonomic classification for denovo-OTUs was made through Wang Classifier with a bootstrap of 80%. Sparse OTUS (<0.001%) were removed from further analysis and taxonomic profiles for both bacterial and fungal data based on OTU annotation were generated at the genera level. Clustered Heatmaps with the rank abundance plot of bacterial and fungal genera were plotted using R software.
4.5. Identification of Contaminant Microbial Reads
To avoid any potential contaminant in the reads, we additionally sequenced DNA extraction (blank) controls and removed those taxa (however at a lesser frequency compared to the test groups) from the datasets of all endophthalmitis patients. We reported only those reads from the pathogens that were not present in the negative and blank (water only) control on the same run and library preparation.