Mitigation Strategies for Overheating and High Carbon Dioxide Concentration within Institutional Buildings: A Case Study in Toronto, Canada

1
Department of Architectural Science, Ryerson University, 350 Victoria St, Toronto, ON M5B 2K3, Canada
2
Department of Electrical, Computer and Biomedical Engineering, Ryerson University, 350 Victoria St, Toronto, ON M5B 2K3, Canada
*
Author to whom correspondence should be addressed.
Buildings 2020, 10(7), 124; https://doi.org/10.3390/buildings10070124
Received: 21 June 2020 / Revised: 3 July 2020 / Accepted: 5 July 2020 / Published: 9 July 2020
Indoor air quality and thermal conditions are important considerations when designing indoor spaces to ensure occupant health, satisfaction, and productivity. Carbon dioxide (CO2) concentration and indoor air temperature are two measurable parameters to assess air quality and thermal conditions within a space. Occupants are progressively affected by the indoor environment as the time spent indoors prolongs. Specifically, there is an interest in carrying out investigations on the indoor environment through surveying existing Heating, Ventilation, Air Conditioning (HVAC) system operations in classrooms. Indoor air temperature and CO2 concentration in multiple lecture halls in Toronto, Canada were monitored; observations consistently show high indoor air temperature (overheating) and high CO2 concentration. One classroom is chosen as a representative case study for this paper. The results verify a strong correlation between the number of occupants and the increase in air temperature and CO2 concentration. Building Energy Simulation (BES) is used to investigate the causes of discomfort in the classroom, and to identify methods for regulating the temperature and CO2 concentration. This paper proposes retro-commissioning strategies that could be implemented in institutional buildings; specifically, the increase of outdoor airflow rate and the addition of occupancy-based pre-active HVAC system control. The proposed retrofit cases reduce the measured overheating in the classrooms by 2-3 °C (indoor temperature should be below 23 °C) and maintain CO2 concentration under 900 ppm (the CO2 threshold is 1000 ppm), showing promising improvements to a classroom’s thermal condition and indoor air quality. View Full-Text
Keywords: Building Energy Simulations; energy efficiency; indoor environmental quality; indoor thermal condition; mechanical ventilation; Occupancy-based HVAC control Building Energy Simulations; energy efficiency; indoor environmental quality; indoor thermal condition; mechanical ventilation; Occupancy-based HVAC control
Show Figures

Figure 1

MDPI and ACS Style

Tam, C.; Zhao, Y.; Liao, Z.; Zhao, L. Mitigation Strategies for Overheating and High Carbon Dioxide Concentration within Institutional Buildings: A Case Study in Toronto, Canada. Buildings 2020, 10, 124. https://doi.org/10.3390/buildings10070124

AMA Style

Tam C, Zhao Y, Liao Z, Zhao L. Mitigation Strategies for Overheating and High Carbon Dioxide Concentration within Institutional Buildings: A Case Study in Toronto, Canada. Buildings. 2020; 10(7):124. https://doi.org/10.3390/buildings10070124

Chicago/Turabian Style

Tam, Claire; Zhao, Yuqing; Liao, Zaiyi; Zhao, Lian. 2020. "Mitigation Strategies for Overheating and High Carbon Dioxide Concentration within Institutional Buildings: A Case Study in Toronto, Canada" Buildings 10, no. 7: 124. https://doi.org/10.3390/buildings10070124

Find Other Styles
Note that from the first issue of 2016, MDPI journals use article numbers instead of page numbers. See further details here.

Article Access Map by Country/Region

1
Search more from Scilit
 
Search
Back to TopTop