Sign in to use this feature.

Years

Between: -

Subjects

remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline

Journals

Article Types

Countries / Regions

Search Results (46)

Search Parameters:
Keywords = sheath current simulation

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
19 pages, 4288 KB  
Article
Simulation of Neural Signals’ Spectrum and Transmission from the Perspective of Impedance-Matching Effect of the Ranvier Node
by Mingwei Song, Zhiming Xu and Jingjing Xu
Bioengineering 2026, 13(8), 955; https://doi.org/10.3390/bioengineering13080955 - 21 Aug 2026
Viewed by 349
Abstract
Addressing the current issues of the uncertain primary frequency bands and the difficulty in directly measuring the spectral characteristics of neural electromagnetic signals transmitted within nerve fibers, this study investigates the spectral and time-domain properties of the neural electromagnetic signals through finite element [...] Read more.
Addressing the current issues of the uncertain primary frequency bands and the difficulty in directly measuring the spectral characteristics of neural electromagnetic signals transmitted within nerve fibers, this study investigates the spectral and time-domain properties of the neural electromagnetic signals through finite element simulations, using the influence of the node of Ranvier on nerve conduction velocity as a breakthrough point, and develops a coaxial transmission line impedance transformation model. The research results demonstrate that the primary signals capable of effective transmission within nerve fibers may reside in the terahertz (THz) band. They also show that the node of Ranvier essentially functions by regulating its geometric length to achieve impedance matching between the node and the myelin sheath, thereby reaching the optimal efficiency for signal coupling. The above finding not only explains the mechanism underlying the non-monotonic variation in neural conduction velocity with the length of the node of Ranvier, but also provides the latest perspective for understanding the relationship and differences between transmembrane action potentials that accompany the generation of neural signals and information transmission carriers—electromagnetic signals. It may also provide a theoretical supplement to the understanding of signal frequency–timing issues in neural encoding. Full article
(This article belongs to the Section Biomedical Engineering and Biomaterials)
Show Figures

Graphical abstract

20 pages, 4368 KB  
Article
Multi-Parameter Sensitivity Analysis and Engineering Configuration Optimization Strategies for Sheath Protectors in 220 kV Cable Systems Based on Overvoltage Characteristic Analysis
by Xiaoyan Ji, Yong Liu and Qiran Li
Energies 2026, 19(12), 2929; https://doi.org/10.3390/en19122929 - 21 Jun 2026
Viewed by 379
Abstract
This paper focuses on 220 kV cable sheath overvoltage caused by three typical operating conditions: harmonics, short-circuits, and lightning strikes. A sheath voltage simulation model on the 220 kV side is developed in PSCAD. Through multi-parameter scanning and sensitivity analysis, the overvoltage characteristics [...] Read more.
This paper focuses on 220 kV cable sheath overvoltage caused by three typical operating conditions: harmonics, short-circuits, and lightning strikes. A sheath voltage simulation model on the 220 kV side is developed in PSCAD. Through multi-parameter scanning and sensitivity analysis, the overvoltage characteristics and key influencing factors are systematically studied, and engineering optimization strategies for sheath protector configuration are proposed for different types of overvoltage. Under harmonic conditions, a suppression circuit composed of discharge capacitance and discharge resistors is proposed to attenuate high-frequency disturbances. Under high-amplitude overvoltage conditions such as short-circuits and lightning strikes, the sheath protector configuration is optimized by adjusting cable length and grounding configuration. Under large current conditions, a parallel configuration scheme for sheath protectors is proposed from the perspective of energy absorption. Multi-condition simulations are conducted, and a simulation-based case study is carried out based on the actual layout and parameters of a traction substation cable line. The results show that the proposed strategies can effectively reduce the peak value of sheath overvoltage, providing simulation-based quantitative engineering guidance for the configuration of 220 kV cable sheath protectors based on sensitivity analysis results. Full article
Show Figures

Figure 1

17 pages, 3321 KB  
Article
Sheath-to-Ground Fault Impedance Calculation and Localization Method in Cross-Bonded High-Voltage Cable Systems
by Hang Wang, Bo Li, Liqiang Wang, Jing Tu, Shuai Yang and Jun Chen
Energies 2026, 19(10), 2458; https://doi.org/10.3390/en19102458 - 20 May 2026
Viewed by 468
Abstract
Abnormal circulating current induced by sheath grounding faults in cross-bonded high-voltage cables is a major cause of single-phase grounding faults. For the early detection and localization of sheath grounding faults, this paper constructs an equivalent circuit model for three-phase nine-section cross-bonded cables. Circuit [...] Read more.
Abnormal circulating current induced by sheath grounding faults in cross-bonded high-voltage cables is a major cause of single-phase grounding faults. For the early detection and localization of sheath grounding faults, this paper constructs an equivalent circuit model for three-phase nine-section cross-bonded cables. Circuit model parameters are estimated via online monitoring data. The relational equation between sheath electrical quantities, fault impedance, and distance is derived for typical sheath grounding faults. Using the Adam algorithm, the solution of fault impedance and location is converted into the minimization of an optimization objective function. Simulation results show that under the influences of phase current imbalance, measurement error, and fault impedance fluctuation, the Adam algorithm exhibits superior optimization accuracy and computational efficiency in comparison with the ED and GA algorithms. Experimental results show that for low-resistance sheath grounding, the proposed method has a fault impedance calculation error ≤ 0.59% and a fault positioning error ≤ 1.89%. For metallic sheath grounding with zero resistance, the positioning error is ≤1.37%. Field test results demonstrate that the proposed method performs similarly to the time-domain reflectometry method, with a positioning deviation ≤ 0.15 m, and can meet online monitoring requirements. Full article
Show Figures

Figure 1

17 pages, 4638 KB  
Article
Simulation Analysis of the Effects of Barrier Defects on the Electro–Thermal Fields of the XLPE Cable Buffer Layer
by Shili Liu and Zhenhao Wei
Energies 2026, 19(6), 1433; https://doi.org/10.3390/en19061433 - 12 Mar 2026
Cited by 2 | Viewed by 748
Abstract
With the increasing number of failures in high-voltage cross-linked polyethylene cables caused by buffer layer ablation, it is of great significance to investigate the electro–thermal coupling characteristics and ablation driving mechanisms under different defect conditions. Based on a multiphysics coupling model, an electro–thermal [...] Read more.
With the increasing number of failures in high-voltage cross-linked polyethylene cables caused by buffer layer ablation, it is of great significance to investigate the electro–thermal coupling characteristics and ablation driving mechanisms under different defect conditions. Based on a multiphysics coupling model, an electro–thermal coupled simulation of the cable buffer layer and corrugated aluminum sheath was carried out, considering three typical defect types: air-gap barrier, moisture ingress, and white-powder barrier. The distributions of air-gap electric field, interfacial current density, temperature, and heat source were systematically analyzed. From the perspective of ablation mechanisms, the maximum air-gap electric field and its spatial location, as well as the maximum temperature of the buffer layer and its corresponding region, were investigated under different defect conditions. Meanwhile, the probabilities of electrical ablation and thermal ablation, together with their corresponding threshold parameters, were quantitatively evaluated. The results show that when an air-gap barrier exists between the buffer layer and the aluminum sheath, air breakdown may occur when the air-gap thickness is approximately 0.01–0.05 mm. When the buffer layer is moisture-contaminated and the defect length exceeds approximately 2 m, the buffer layer temperature may exceed 165 °C. When white-powder precipitates in the buffer layer, partial discharge may be initiated at the early stage. With the increase in powder barrier proportion, the buffer layer temperature may exceed approximately 220 °C. It should be noted that these critical characteristics are obtained under the simulation conditions of this study. The specific values depend on material parameters and operating conditions and can provide theoretical support for cable operation condition assessment. Full article
Show Figures

Figure 1

28 pages, 2499 KB  
Article
Cross-Bonded Cable Circuits Identification Based on Deep Embedded Clustering of Sheath Current Sensing
by Hang Wang, Zhi Li, Wenfang Ding, Jing Tu, Liqiang Wang and Jun Chen
Sensors 2026, 26(5), 1591; https://doi.org/10.3390/s26051591 - 3 Mar 2026
Cited by 1 | Viewed by 670
Abstract
Online identification of HV cable circuits is vital for routine inspection and maintenance, yet existing passive electromagnetic wave injection methods are limited to offline operations. To fill the gap and achieve the online identification of HV cable circuits, an online circuit identification methodology [...] Read more.
Online identification of HV cable circuits is vital for routine inspection and maintenance, yet existing passive electromagnetic wave injection methods are limited to offline operations. To fill the gap and achieve the online identification of HV cable circuits, an online circuit identification methodology based on sheath current temporal characteristics and deep embedded clustering is proposed. First, an equivalent circuit model of the multi-circuit cross-bonded cable sheath was built to deduce the temporal similarity of sheath currents within the same circuit, establishing the identification criterion. Second, the robustness of the temporal similarity under various operating conditions was verified via simulation based on the Dynamic Time Warping (DTW) distance. Then, a combined model of Temporal Convolutional Network Autoencoder (TCN-AE) and K-medoids was established to transform circuit identification into a temporal clustering problem of sheath currents, realizing circuit determination by synchronously monitoring the time-series sheath current data of multi-circuit HV cross-bonded cables. The method was verified on a full-scale 110 kV cable test platform. The results show that the identification accuracy reached 95.37%, and the proposed method can effectively identify the circuits of cross-bonded cables with high robustness against the domain gap, having significant engineering application value. Full article
(This article belongs to the Special Issue Sensor-Based Fault Diagnosis and Prognosis)
Show Figures

Figure 1

25 pages, 5072 KB  
Article
Air-Shielding Radial Ultrasonic Rolling Electrochemical Micromachining for Localized Micro-Dimple Arrays on Cylindrical SS304
by Wenjun Tong, Yunfeng Tan and Lin Li
Processes 2026, 14(4), 636; https://doi.org/10.3390/pr14040636 - 12 Feb 2026
Viewed by 677
Abstract
Air-shielding radial ultrasonic rolling electrochemical micromachining (AS-RUREMM) is proposed to fabricate high-quality micro-dimple textures on cylindrical SS304 surfaces while suppressing stray corrosion. In AS-RUREMM, an annular air sheath coaxially envelopes the electrolyte jet to confine the wetting footprint, and radial ultrasonic vibration is [...] Read more.
Air-shielding radial ultrasonic rolling electrochemical micromachining (AS-RUREMM) is proposed to fabricate high-quality micro-dimple textures on cylindrical SS304 surfaces while suppressing stray corrosion. In AS-RUREMM, an annular air sheath coaxially envelopes the electrolyte jet to confine the wetting footprint, and radial ultrasonic vibration is superimposed on a rolling cathode with micro-protrusions to intensify local mass transport and stabilize the interelectrode environment. A conductivity-centered theoretical framework is established to link air-sheathing-induced gas–liquid distribution, ultrasonic gap modulation, and the resulting current-density localization. Multiphysics simulations in COMSOL 5.3 clarify that moderate air pressure forms a stable confined gas–liquid structure that narrows the effective conductive pathway, whereas excessive air pressure increases intermittency and weakens effective gap conductivity. Experiments on SS304 tubes validate the confinement mechanism: compared with RUREMM, AS-RUREMM produces smaller pit width and depth but a higher depth-to-width ratio, indicating enhanced localization and reduced peripheral over-etching. The simulated cross-sectional profiles agree with measurements, with an overall deviation within 6%. Parameter studies identify an optimal operating window, and the combination of 0.18 MPa air pressure and 12 V pulse voltage provides the highest aspect ratio while maintaining stable machining. SEM/EDX analyses further support the improved process controllability under air shielding through reduced stray corrosion and composition changes consistent with a more regulated electrochemical dissolution environment. Full article
(This article belongs to the Section Manufacturing Processes and Systems)
Show Figures

Figure 1

20 pages, 2421 KB  
Article
Insulation Monitoring and Fault Diagnosis Technology of Cross-Bonded Metal-Sheathed Cable
by Chunming Wei, Dewen Zhang, Chao Xu, Long Tan, Zhongzhi Qu and Bo Zhu
Energies 2026, 19(3), 698; https://doi.org/10.3390/en19030698 - 28 Jan 2026
Cited by 2 | Viewed by 639
Abstract
For addressing the challenge that cross-interconnection of metal sheaths in long-distance high-voltage cables complicates the monitoring of cable insulation faults, it is proposed a fault diagnosis scheme based on resistive current, dielectric loss factor, and sheath current. The voltage and current signals at [...] Read more.
For addressing the challenge that cross-interconnection of metal sheaths in long-distance high-voltage cables complicates the monitoring of cable insulation faults, it is proposed a fault diagnosis scheme based on resistive current, dielectric loss factor, and sheath current. The voltage and current signals at both ends of the cable are collected, as well as the current signals at the outlet of the grounding box and the transposition box. By establishing an equivalent model of the cross-connected cable, the calculation method for fault diagnosis is derived, and an implementation scheme for fault diagnosis is provided. The insulation monitoring method proposed in this paper is simulated and verified using MATLAB/Simulink software, with simulations conducted to investigate four typical faults: cable insulation fault, sheath open-circuit fault, transposition box immersion short-circuit fault, and cable intermediate-joint breakdown fault. The circuit model of the cross-connected unit is established in the laboratory to verify the method proposed in this paper. The results show that the simulation results are consistent with the test results, and the fault types can be correctly reflected, which verifies the correctness and effectiveness of the insulation monitoring method. Full article
(This article belongs to the Section F1: Electrical Power System)
Show Figures

Figure 1

28 pages, 8096 KB  
Article
Numerical Investigation of Perforation in Microcrack Propagation and Damage Analysis at the Cement Sheath
by Yu Yao, Yan Xi, Jian He, Jianhua Zhao, Xianming Sun and Ming Liu
Appl. Sci. 2026, 16(2), 805; https://doi.org/10.3390/app16020805 - 13 Jan 2026
Viewed by 622
Abstract
Wellbore integrity maintenance constitutes a fundamental safety and technological challenge throughout the entire lifecycle of oil and gas wells (including production, injection, and CO2 sequestration operations). As a critical completion phase, perforation generates a high-temperature, high-pressure shaped charge jet that impacts and [...] Read more.
Wellbore integrity maintenance constitutes a fundamental safety and technological challenge throughout the entire lifecycle of oil and gas wells (including production, injection, and CO2 sequestration operations). As a critical completion phase, perforation generates a high-temperature, high-pressure shaped charge jet that impacts and compromises wellbore structural integrity. This process may induce failure in both the cement sheath body and its interfacial zones, potentially creating fluid migration pathways along the cement-casing interface through perforation tunnels. Current research remains insufficient in quantitatively evaluating cement sheath damage resulting from perforation operations. Addressing this gap, this study incorporates dynamic jet effects during perforation and establishes a numerical model simulating high-velocity jet penetration through casing–cement target–formation composites using a rock dynamics-based constitutive model. The investigation analyzes failure mechanisms within the cement sheath matrix and its boundaries during perforation penetration, while examining the influence of mechanical parameters (compressive strength and shear modulus) of both cement sheath and formation on damage characteristics. Results demonstrate that post-perforation cement sheath aperture exhibits convergent–divergent profiles along the tunnel axis, containing exclusively radial fractures. Primary fractures predominantly initiate at the inner cement wall, whereas microcracks mainly develop at the outer boundary. Enhanced cement compressive strength significantly suppresses fracture initiation at both boundaries: when increasing from 55 MPa to 75 MPa, the undamaged area ratio rises by 16.6% at the inner wall versus 11.2% at the outer interface. Meanwhile, increasing the formation shear modulus from 10 GPa to 15 GPa reduces cement target failure radius by 0.4 cm. Cement systems featuring high compressive strength and low shear modulus demonstrate superior performance in mitigating perforation-induced debonding. Full article
(This article belongs to the Section Civil Engineering)
Show Figures

Figure 1

24 pages, 9453 KB  
Article
Study on Electromagnetic–Thermal Coupling Characteristics of Submarine Cable Using Finite Element Method
by Kui Zhu, Yicheng Zhang, Qingyang Duan, Peng Liang, Zhihong Wang, Zeqi Cheng and Enjin Zhao
J. Mar. Sci. Eng. 2026, 14(2), 132; https://doi.org/10.3390/jmse14020132 - 8 Jan 2026
Cited by 3 | Viewed by 1172
Abstract
Low-frequency alternating-current (LFAC) transmission has attracted significant attention for medium- and long-distance offshore wind integration due to its ability to mitigate the substantial charging currents and reactive power burdens associated with long submarine cables. This paper investigates the frequency-dependent electrothermal behaviors of a [...] Read more.
Low-frequency alternating-current (LFAC) transmission has attracted significant attention for medium- and long-distance offshore wind integration due to its ability to mitigate the substantial charging currents and reactive power burdens associated with long submarine cables. This paper investigates the frequency-dependent electrothermal behaviors of a 500 kV three-core XLPE submarine cable using a coupled electromagnetic–thermal finite-element model. The simulation framework evaluates the current distribution, power losses in metallic components, temperature rise, and ampacity across various frequency regimes. To validate the numerical model, a thermal-circuit approach based on the IEC 60287 standard is developed, with comparisons confirming that deviations remain within acceptable engineering margins. The study reveals that operating at lower frequencies effectively mitigates skin and proximity effects, leading to reduced conductor and sheath losses. Quantitative results demonstrate that reducing the operating frequency from 50 Hz to 5 Hz results in a 30.6% reduction in total power losses and a 14.2% increase in current-carrying capability. These findings confirm that LFAC transmission offers a viable pathway to enhance the efficiency and capacity of submarine power transmission systems. Full article
(This article belongs to the Section Ocean Engineering)
Show Figures

Figure 1

19 pages, 2166 KB  
Article
A Modified Ampacity Calculation Method for High-Voltage Cables Considering Grounding Modes
by Qianqiu Shao, Songhai Fan, Zongxi Zhang, Fenglian Liu, Jinkui Lu, Zhengzheng Fu and Pinlei Lv
Appl. Sci. 2025, 15(24), 13071; https://doi.org/10.3390/app152413071 - 11 Dec 2025
Viewed by 1076
Abstract
To address the limitation of the IEC 60287 standard in accurately representing the electrothermal characteristics of cables under different grounding conditions, this study proposes a modified equivalent thermal resistance method, using a YJLW03-Z 64/110 1 × 1200 mm2 high-voltage single-core cable as [...] Read more.
To address the limitation of the IEC 60287 standard in accurately representing the electrothermal characteristics of cables under different grounding conditions, this study proposes a modified equivalent thermal resistance method, using a YJLW03-Z 64/110 1 × 1200 mm2 high-voltage single-core cable as a case study to analyze three typical grounding modes, namely two-end solid bonding, segmented solid bonding, and semiconductive outer sheath. Equivalent circuit models are established to calculate the induced current, voltage, and losses of the metallic sheath and armor. Based on these results, the equivalent thermal resistance model is modified, and correction formulas for cable ampacity considering grounding effects are derived. The proposed model is validated through numerical simulations under typical laying conditions and field tests conducted in Zhoushan, Zhejiang Province. Results show that grounding modes significantly influence the electromagnetic losses and temperature distribution of cables. Segmented solid bonding effectively reduces sheath losses and increases ampacity, while its enhancement tends to stabilize beyond two bonding sections. The semiconductive outer sheath improves electric field distribution and thermal stability with limited ampacity gain. This study provides theoretical guidance and engineering reference for optimizing grounding designs, ampacity evaluation, and digital operation of high-voltage cable systems. Full article
(This article belongs to the Section Electrical, Electronics and Communications Engineering)
Show Figures

Figure 1

18 pages, 7434 KB  
Article
Analysis of Decay-like Fracture Failure in Core Rods of On-Site Composite Interphase Spacers of 500 kV Overhead Power Transmission Lines
by Chao Gao, Xinyi Yan, Wei Yang, Lee Li, Shiyin Zeng and Guanjun Zhang
Electronics 2025, 14(23), 4750; https://doi.org/10.3390/electronics14234750 - 2 Dec 2025
Viewed by 770
Abstract
Composite interphase spacers are essential components in ultra-high-voltage (UHV) transmission lines to suppress conductor galloping. This study investigates the first reported case of a core-rod fracture in a 500 kV composite spacer and elucidates its degradation mechanism through multi-scale characterization, electrical testing combined [...] Read more.
Composite interphase spacers are essential components in ultra-high-voltage (UHV) transmission lines to suppress conductor galloping. This study investigates the first reported case of a core-rod fracture in a 500 kV composite spacer and elucidates its degradation mechanism through multi-scale characterization, electrical testing combined and electric field and mechanical simulation. Macroscopic inspection and industrial computed tomography (CT) show that degradation initiated at the unsheltered high-voltage sheath–core interface and propagated axially, accompanied by continuous interfacial cracks and void networks whose volume ratio gradually decreased along the spacer. Material characterizations indicate moisture-driven glass-fiber hydrolysis, epoxy oxidation, and progressive interfacial debonding. Leakage current test further indicates humidity-sensitive conductive paths in the degraded region, confirming the presence of moisture-activated interfacial channels. Electric-field simulations under two shed configurations demonstrated that local field intensification was concentrated within 20–30 cm of the HV terminal, where the sheath and core surface fields increased by approximately 9.3% and 5.5%. Mechanical modeling demonstrates a pronounced bending-induced stress concentration at the same end region. The combined effects of moisture ingress, electrical stress, mechanical loading, and chemical degradation lead to the decay-like fracture. Improving sheath hydrophobicity, enhancing interfacial bonding, and optimizing end-fitting geometry are recommended to mitigate such failures and ensure the long-term reliability of UHV composite interphase spacers. Full article
(This article belongs to the Special Issue Polyphase Insulation and Discharge in High-Voltage Technology)
Show Figures

Figure 1

18 pages, 4640 KB  
Article
Cable Outer Sheath Defect Identification Using Multi-Scale Leakage Current Features and Graph Neural Networks
by Musong Lin, Hankun Wei, Xukai Duan, Zhi Li, Qiang Fu and Yong Liu
Energies 2025, 18(21), 5687; https://doi.org/10.3390/en18215687 - 29 Oct 2025
Cited by 1 | Viewed by 935
Abstract
The outer sheath of power cables is prone to mechanical damage and environmental stress during long-term operation, and early defects are often difficult to detect accurately using conventional methods. To address this challenge, this paper proposes an outer sheath defect identification method based [...] Read more.
The outer sheath of power cables is prone to mechanical damage and environmental stress during long-term operation, and early defects are often difficult to detect accurately using conventional methods. To address this challenge, this paper proposes an outer sheath defect identification method based on leakage current features and graph neural networks. An electro–thermal coupling physical model was first proposed to simulate the electric field distribution and thermal effects under typical defects, thereby revealing the mechanisms by which defects influence leakage current and harmonic components. A power-frequency high-voltage experimental platform was then constructed to collect leakage current signals under conditions such as scratches, indentations, moisture, and chemical corrosion. Multi-scale frequency band features were extracted using wavelet packet decomposition to construct correlation graphs, which were further modeled through a combination of graph convolutional networks and long short-term memory networks for spatiotemporal analysis. Experimental results demonstrate that the proposed method effectively improves defect type and severity identification. By integrating physical mechanism analysis with data-driven modeling, this approach provides a feasible pathway for condition monitoring and refined operation and maintenance of cable outer sheaths. Full article
Show Figures

Figure 1

16 pages, 2928 KB  
Article
PIC Modeling of Ionospheric Plasma Diagnostics by Hemispherical Probes: Study of the LAP-CSES at Magnetic Conjugates
by Nadia Imtiaz, Saeed Ur Rehman, Liu Chao, Rui Yan and Richard Marchand
Plasma 2025, 8(4), 39; https://doi.org/10.3390/plasma8040039 - 30 Sep 2025
Viewed by 2060
Abstract
We present three dimensional particle-in-cell simulations of current-voltage characteristics of the hemispherical Langmuir probe (LAP), onboard the China Seismo-Electromagnetic Satellite (CSES). Using realistic plasma parameters and background magnetic fields obtained from the International Reference Ionosphere (IRI) and International Geomagnetic Reference Field (IGRF) models, [...] Read more.
We present three dimensional particle-in-cell simulations of current-voltage characteristics of the hemispherical Langmuir probe (LAP), onboard the China Seismo-Electromagnetic Satellite (CSES). Using realistic plasma parameters and background magnetic fields obtained from the International Reference Ionosphere (IRI) and International Geomagnetic Reference Field (IGRF) models, we simulate probe–plasma interactions at three locations: the equatorial region and two magnetically conjugate mid-latitude sites: Millstone Hill (Northern Hemisphere) and Rothera (Southern Hemisphere). The simulations, performed using the PTetra PIC code, incorporate realistic LAP geometry and spacecraft motion in the ionospheric plasma. Simulated current voltage characteristics or I–V curves are compared against in-situ LAP measurements from CSES Orbit-026610, with Pearson’s correlation coefficients used to assess agreement. Our findings indicate how plasma temperature, density, and magnetization affect sheath structure and probe floating potential. The study highlights the significance of kinetic modeling in enhancing diagnostic accuracy, particularly in variable sheath regimes where classic analytical models such as the Orbital-Motion-Limited (OML) theory may be inadequate. Full article
Show Figures

Figure 1

19 pages, 2136 KB  
Article
Two-Sheath Loop Short Circuit Defects Detection in High-Voltage Cable Systems Using Sheath Current Phasors
by Weihua Yuan, Jing Tu, Yongheng Ai, Zhanran Xia, Ruoxin Song, Jianfeng He, Xinyun Gao, Minghong Jiang, Bin Yang, Bo Li and Hang Wang
Energies 2025, 18(18), 4868; https://doi.org/10.3390/en18184868 - 12 Sep 2025
Cited by 2 | Viewed by 1001
Abstract
The joint is the weak point of HV (high voltage) cable insulation systems; creep discharge between insulation layers of the cable joint, due to moisture intrusion, is one of the main defects leading to single-phase grounding. Carbonization on the insulation interface after creep [...] Read more.
The joint is the weak point of HV (high voltage) cable insulation systems; creep discharge between insulation layers of the cable joint, due to moisture intrusion, is one of the main defects leading to single-phase grounding. Carbonization on the insulation interface after creep discharge would lead to a short-circuit defect in the sheath loops and result in abnormal sheath current. In this study, a novel diagnostic criterion using the phasor difference of sheath currents at both ends of the same circuit is proposed. The coupling effect between the sheath and the conductor under defect conditions is considered, and the original lumped parameter model of the cable circuit is optimized. The cable parameters are further corrected using a genetic algorithm. The diagnostic criterion comprehensively accounts for the adverse effects of unequal cable segment lengths, load current fluctuations, grounding impedance, and phase voltage variations. When the phase angle fluctuation of the phasor difference is within 10° and the defect impedance is below 100 Ω, the defective joint can be accurately diagnosed by this method. The conclusion has been validated through PSCAD simulations, with a diagnostic accuracy above 97%. Even under 20 dB noise interference, the error increase remains within 2%. Full article
Show Figures

Figure 1

16 pages, 3697 KB  
Article
Studies of Voltages Induced in the Screens of Power Cables Using Computer Simulation on an MV Network Model
by Aleksandra Schött-Szymczak and Krzysztof Walczak
Energies 2025, 18(17), 4607; https://doi.org/10.3390/en18174607 - 30 Aug 2025
Viewed by 1657
Abstract
One of the reasons for using metallic sheaths in power cables is to provide a path for fault current flow. The aim of the study will be to determine the effect of the type of short circuit, the current that flows in the [...] Read more.
One of the reasons for using metallic sheaths in power cables is to provide a path for fault current flow. The aim of the study will be to determine the effect of the type of short circuit, the current that flows in the conductor of a three-phase MV cable line, on the level of voltages and overvoltages induced in the metallic screens of these cables with different configurations of their grounding. The appearance of voltage exceeding safe values in the screen can lead to damage to the outer sheath insulation cable. The simulation studies were carried out using an MV network model created in the DIgSILENT Power Factory program, which consists of basic elements of the power system and a system that duplicates connections of sheaths and grounding. The test results show the waveforms of voltages induced in the cable screens and the maximum values of overvoltage resulting from the simulation of ground faults and phase faults. The main achievement obtained as a result of the simulation tests was obtaining information on the level of overvoltage hazard in the event of various types of short-circuit disturbances. The analysis of the obtained results indicates the possibility of overvoltage in the considered system, posing a threat to the outer sheath of the cable; therefore, a solution will be proposed to avoid damage. Full article
(This article belongs to the Special Issue Power System Voltage Stability, Modelling, Analysis and Control)