Sign in to use this feature.

Years

Between: -

Subjects

remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline

Journals

Article Types

Countries / Regions

Search Results (98)

Search Parameters:
Keywords = scintillator 1

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
16 pages, 2899 KB  
Article
Development of a Radioactive Sorting and Volume Reduction System for Radioactive Contaminated Sandy Soil Using Plastic Scintillator and NaI Detectors
by Chengzhou Fan, Zhenxing Liu, Jinshuai Yang, Rui Li and Jianbo Yang
Sensors 2025, 25(24), 7458; https://doi.org/10.3390/s25247458 - 8 Dec 2025
Viewed by 179
Abstract
Radioactively contaminated sandy soil is commonly encountered during nuclear facility decommissioning and nuclear accident response, and its rapid sorting and volume reduction are crucial for achieving waste minimization and lowering remediation costs. This study designed and developed a radiation measurement system based on [...] Read more.
Radioactively contaminated sandy soil is commonly encountered during nuclear facility decommissioning and nuclear accident response, and its rapid sorting and volume reduction are crucial for achieving waste minimization and lowering remediation costs. This study designed and developed a radiation measurement system based on a large-volume plastic scintillator and a NaI array detector, focusing on the design, implementation, and performance validation of its radiation detection and signal processing subsystems. The system employed differential measurement to obtain the net radioactive count rate of sandy soil, while enhancing energy spectrum stability through programmable gain control and temperature stabilization. Experimental results demonstrated that both plastic scintillator arrays effectively achieved dynamic background subtraction within a 1.8 s measurement cycle, with net count rate errors controlled below 10%. The NaI detector array achieved an energy resolution better than 8% at 662 keV, with the peak channel drift within ±1 channel. Rapid activity measurements for radioactive sources such as 241Am and 137Cs exhibited errors below 10%, meeting the key technical requirements for sandy soil separation and volume reduction. These findings provided data support and methodological reference for subsequent system integration and engineering application of sorting and volume reduction equipment. Full article
(This article belongs to the Special Issue Detectors & Sensors in Nuclear Physics and Nuclear Astrophysics)
Show Figures

Figure 1

21 pages, 3735 KB  
Article
Estimating Ionospheric Phase Scintillation Indices in the Polar Region from 1 Hz GNSS Observations Using Machine Learning
by Zhuojun Han, Ruimin Jin, Longjiang Chen, Weimin Zhen, Huaiyun Peng, Huiyun Yang, Mingyue Gu, Xiang Cui and Guangwang Ji
Remote Sens. 2025, 17(17), 3073; https://doi.org/10.3390/rs17173073 - 3 Sep 2025
Viewed by 1445
Abstract
Ionospheric scintillation represents a disturbance phenomenon induced by irregular electron density variations, predominantly occurring in equatorial, auroral, and polar regions, thereby posing significant threats to Global Navigation Satellite Systems (GNSS) performance. Polar regions in particular confront distinctive challenges, including the sparse deployment of [...] Read more.
Ionospheric scintillation represents a disturbance phenomenon induced by irregular electron density variations, predominantly occurring in equatorial, auroral, and polar regions, thereby posing significant threats to Global Navigation Satellite Systems (GNSS) performance. Polar regions in particular confront distinctive challenges, including the sparse deployment of dedicated ionospheric scintillation monitoring receiver (ISMR) equipment, the limited availability of strong scintillation samples, severely imbalanced training datasets, and the insufficient sensitivity of conventional Deep Neural Networks (DNNs) to intense scintillation events. To address these challenges, this study proposes a modeling framework that integrates residual neural networks (ResNet) with the Synthetic Minority Over-sampling Technique for Regression with Gaussian Noise (SMOGN). The proposed model incorporates multi-source disturbance features to accurately estimate phase scintillation indices (σφ) in polar regions. The methodology was implemented and validated across multiple polar observation stations in Canada. Shapley Additive Explanations (SHAP) interpretability analysis reveals that the rate of total electron content index (ROTI) features contribute up to 64.09% of the predictive weight. The experimental results demonstrate a substantial performance enhancement compared with conventional DNN models, with root mean square error (RMSE) values ranging from 0.0078 to 0.038 for daytime samples in 2024, and an average coefficient of determination (R2) consistently exceeding 0.89. The coefficient of determination for the Pseudo-Random Noise (PRN) path estimation results can reach 0.91. The model has good estimation results at different latitudes and is able to accurately capture the distribution characteristics of the local strong scintillation structures and their evolution patterns. Full article
(This article belongs to the Section Atmospheric Remote Sensing)
Show Figures

Figure 1

15 pages, 1110 KB  
Article
Natural Radionuclides 222Rn and 226Ra in Shallow Groundwater of Nysa County (SW Poland): Concentrations, Background, and Radiological Risk
by Piotr Maciejewski and Jakub Ładziński
Water 2025, 17(17), 2596; https://doi.org/10.3390/w17172596 - 2 Sep 2025
Viewed by 1294
Abstract
Natural radionuclides may occur in groundwater and pose health risks when present in elevated concentrations. This study evaluates the quality of shallow groundwater in Nysa County (SW Poland) based on the activity concentrations of natural radionuclides radon (222Rn) and radium ( [...] Read more.
Natural radionuclides may occur in groundwater and pose health risks when present in elevated concentrations. This study evaluates the quality of shallow groundwater in Nysa County (SW Poland) based on the activity concentrations of natural radionuclides radon (222Rn) and radium (226Ra) and estimates the associated radiological risk from water ingestion. Twenty-three groundwater samples were collected from private wells located within two distinct geological units: the Fore-Sudetic Block and the Opole Trough. Activity concentrations of 222Rn and 226Ra were measured using the liquid scintillation counting method. A spatial distribution model for 222Rn was developed using inverse distance weighting in QGIS. Local hydrogeochemical background levels were determined using the Q-Dixon test, interquartile range, and Shapiro–Wilk normality test. The background ranged from 2.6 to 3.9 Bq·L−1 in the Opole Trough and from 0 to 10.7 Bq·L−1 in the Fore-Sudetic Block. The lower detection limit (0.05 Bq·L−1) for 226Ra activity concentration measurements was not exceeded. Effective dose rates were calculated in accordance with the recommendations of the International Commission on Radiological Protection and United Nations Scientific Committee on the Effects of Atomic Radiation. Doses ranged from <1 µSv to over 120 µSv·y−1. Although all samples met national regulatory standards (≤1 mSv·y−1), the World Health Organization reference level (0.1 mSv·y−1) was exceeded in two cases. The results support the need for the radiological monitoring of unregulated private wells and provide a scientific basis for the refinement of legal frameworks and health protection strategies. Full article
(This article belongs to the Section Hydrogeology)
Show Figures

Figure 1

16 pages, 838 KB  
Article
A Scintillation Hodoscope for Measuring the Flux of Cosmic Ray Muons at the Tien Shan High Mountain Station
by Alexander Shepetov, Aliya Baktoraz, Orazaly Kalikulov, Svetlana Mamina, Yerzhan Mukhamejanov, Kanat Mukashev, Vladimir Ryabov, Nurzhan Saduyev, Turlan Sadykov, Saken Shinbulatov, Tairzhan Skokbayev, Ivan Sopko, Shynbolat Utey, Ludmila Vildanova, Nurzhan Yerezhep and Valery Zhukov
Particles 2025, 8(3), 73; https://doi.org/10.3390/particles8030073 - 4 Aug 2025
Viewed by 911
Abstract
For further investigation of the properties of the muon component in the core regions of extensive air showers (EASs), a new underground hodoscopic set-up with a total sensitive area of 22 m2 was built at the Tien Shan High Mountain Cosmic Ray [...] Read more.
For further investigation of the properties of the muon component in the core regions of extensive air showers (EASs), a new underground hodoscopic set-up with a total sensitive area of 22 m2 was built at the Tien Shan High Mountain Cosmic Ray Station. The hodoscope is based on a set of large-sized scintillation charged particle detectors with an output signal of analog type. The installation ensures a (5–8) GeV energy threshold of muon registration and a ∼104 dynamic range for the measurement of the density of muon flux. A program facility was designed that uses modern machine learning techniques for automated search for the typical scintillation pulse pattern in an oscillogram of a noisy analog signal at the output of the hodoscope detector. The program provides a ∼99% detection probability of useful signals, with a relative share of false positives below 1%, and has a sufficient operation speed for real-time analysis of incoming data. Complete verification of the hardware and software tools was performed under realistic operation conditions, and the results obtained demonstrate the correctness of the proposed method and its practical applicability to the investigation of the muon flux in EASs. In the course of the installation testing, a preliminary physical result was obtained concerning the rise of the multiplicity of muon particles around an EAS core in dependence on the primary EAS energy. Full article
(This article belongs to the Section Experimental Physics and Instrumentation)
Show Figures

Figure 1

20 pages, 3209 KB  
Article
Experimental Evaluation of GAGG:Ce Crystalline Scintillator Properties Under X-Ray Radiation
by Anastasios Dimitrakopoulos, Christos Michail, Ioannis Valais, George Fountos, Ioannis Kandarakis and Nektarios Kalyvas
Crystals 2025, 15(7), 590; https://doi.org/10.3390/cryst15070590 - 23 Jun 2025
Cited by 2 | Viewed by 2083
Abstract
The scope of this study was to evaluate the response of Ce-doped gadolinium aluminum gallium garnet (GAGG:Ce) crystalline scintillator under medical X-ray irradiation for medical imaging applications. A 10 × 10 × 10 mm3 crystal was irradiated at X-ray tube voltages ranging [...] Read more.
The scope of this study was to evaluate the response of Ce-doped gadolinium aluminum gallium garnet (GAGG:Ce) crystalline scintillator under medical X-ray irradiation for medical imaging applications. A 10 × 10 × 10 mm3 crystal was irradiated at X-ray tube voltages ranging from 50 kVp to 150 kVp. The crystal’s compatibility with several commercially available optical photon detectors was evaluated using the spectral matching factor (SMF) along with the absolute efficiency (AE) and the effective efficiency (EE). In addition, the energy-absorption efficiency (EAE), the quantum-detection efficiency (QDE) as well as the zero-frequency detective quantum detection efficiency DQE(0) were determined. The crystal demonstrated satisfactory AE values as high as 26.3 E.U. (where 1 E.U. = 1 μW∙m−2/(mR∙s−1)) at 150 kVp, similar, or in some cases, even superior to other cerium-doped scintillator materials. It also exhibits adequate DQE(0) performance ranging from 0.99 to 0.95 across all the examined X-ray tube voltages. Moreover, it showed high spectral compatibility with commonly used photoreceptors in modern day such as complementary metal–oxide–semiconductors (CMOS) and charge-coupled-devices (CCD) with SMF values of 0.95 for CCD with broadband anti-reflection coating and 0.99 for hybrid CMOS blue. The aforementioned properties of this scintillator material were indicative of its superior efficiency in the examined medical energy range, compared to other commonly used scintillators. Full article
(This article belongs to the Special Issue Exploring New Materials for the Transition to Sustainable Energy)
Show Figures

Figure 1

12 pages, 2965 KB  
Article
Tailoring Luminescence and Scintillation Properties of Tb3+-Doped LuYAGG Single Crystals for High-Performance Radiation Detection
by Prapon Lertloypanyachai, Prom Kantuptim, Eakapon Kaewnuam, Toshiaki Kunikata, Yusuke Endo, Weerapong Chewpraditkul, Takumi Kato, Daisuke Nakauchi, Noriaki Kawaguchi, Kenichi Watanabe and Takayuki Yanagida
Appl. Sci. 2025, 15(12), 6888; https://doi.org/10.3390/app15126888 - 18 Jun 2025
Cited by 2 | Viewed by 878
Abstract
In this study, Lu2.5Y0.5(Al2.5Ga2.5)O12 (LuYAGG) single-crystal scintillators doped with terbium ions (Tb3+) at concentrations of 0.5, 1, 5, and 10 mol% were successfully synthesized using the floating zone method. The structural, optical, [...] Read more.
In this study, Lu2.5Y0.5(Al2.5Ga2.5)O12 (LuYAGG) single-crystal scintillators doped with terbium ions (Tb3+) at concentrations of 0.5, 1, 5, and 10 mol% were successfully synthesized using the floating zone method. The structural, optical, photoluminescence (PL), and scintillation properties of the Tb3+-doped crystals were systematically investigated with a focus on their potential for high-performance scintillator applications. X-ray diffraction (XRD) confirmed the formation of a pure garnet phase without any secondary phases, indicating the successful incorporation of Tb3+ into the LuYAGG lattice. Optical transmittance spectra revealed high transparency in the visible range. Photoluminescence measurements showed characteristic Tb3+ emission peaks, with the strongest green emission observed from the 5D47F5 transition, particularly for the 5 mol% sample. The PL decay curves further confirmed that this concentration offers a favorable balance between radiative efficiency and minimal non-radiative losses. Under γ-ray excitation, the 5 mol% Tb3+-doped crystal exhibited the highest light yield, surpassing the performance of other concentrations and even outperforming Bi4Ge3O12 (BGO) in relative comparison, with an estimated yield of approximately 60,000 photons/MeV. Scintillation decay time analysis revealed that the 5 mol% sample also possessed the fastest decay component, indicating its superior capability for radiation detection. Although 10 mol% Tb3+ still showed good performance, slight quenching effects were observed, while lower concentrations (0.5 and 1 mol%) suffered from longer decay and lower emission efficiency due to limited activator density. These findings clearly identify with 5 mol% Tb3+ as the optimal dopant level in LuYAGG single crystals, offering a synergistic combination of high light yield and excellent optical transparency. This work highlights the strong potential of LuYAGG:Tb3+ as a promising candidate for the next-generation scintillator materials used in medical imaging, security scanning, and high-energy physics applications. Full article
(This article belongs to the Section Materials Science and Engineering)
Show Figures

Figure 1

31 pages, 7090 KB  
Article
Analysis of the Integrated Signal Design for Near-Space Communication, Navigation, and TT&C Based on K/Ka Frequency Bands
by Lvyang Ye, Shaojun Cao, Zhifei Gu, Deng Pan, Binhu Chen, Xuqian Wu, Kun Shen and Yangdong Yan
Atmosphere 2025, 16(5), 586; https://doi.org/10.3390/atmos16050586 - 13 May 2025
Cited by 1 | Viewed by 1913
Abstract
With its unique environment and strategic value, the near space (NS) has become the focus of global scientific and technological, military, and commercial fields. Aiming at the problem of communication interruption when the aircraft re-enters the atmosphere, to ensure the needs of communication, [...] Read more.
With its unique environment and strategic value, the near space (NS) has become the focus of global scientific and technological, military, and commercial fields. Aiming at the problem of communication interruption when the aircraft re-enters the atmosphere, to ensure the needs of communication, navigation, and telemetry, tracking, and command (TT&C), this paper proposes an overall integration of communication, navigation, and TT&C (ICNT) signals scheme based on the K/Ka frequency band. Firstly, the K/Ka frequency band is selected according to the ITU frequency division, high-speed communication requirements, advantages of space-based over-the-horizon relay, overcoming the blackout problem, and the development trend of high frequencies. Secondly, the influence of the physical characteristics of the NS on ICNT is analyzed through simulation. The results show that when the K/Ka signal is transmitted in the NS, the path loss changes significantly with the elevation angle. The bottom layer loss at an elevation angle of 90° is between 143.5 and 150.5 dB, and the top layer loss is between 157.5 and 164.4 dB; the maximum attenuation of the bottom layer and the top layer at an elevation angle of 0° is close to 180 dB and 187 dB, respectively. In terms of rainfall attenuation, when a 30 GHz signal passes through a 100 km rain area under moderate rain conditions, the horizontal and vertical polarization losses reach 225 dB and 185 dB, respectively, and the rainfall attenuation increases with the increase in frequency. For gas absorption, the loss of water vapor is higher than that of oxygen molecules; when a 30 GHz signal is transmitted for 100 km, the loss of water vapor is 17 dB, while that of oxygen is 2 dB. The loss of clouds and fog is relatively small, less than 1 dB. Increasing the frequency and the antenna elevation angle can reduce the atmospheric scintillation. In addition, factors such as the plasma sheath and multipath also affect the signal propagation. In terms of modulation technology, the constant envelope signal shows an advantage in spectral efficiency; the new integrated signal obtained by integrating communication, navigation, and TT&C signals into a single K/Ka frequency point has excellent characteristics in the simulation of power spectral density (PSD) and autocorrelation function (ACF), verifying the feasibility of the scheme. The proposed ICNT scheme is expected to provide an innovative solution example for the communication, navigation, and TT&C requirements of NS vehicles during the re-entry phase. Full article
(This article belongs to the Section Atmospheric Techniques, Instruments, and Modeling)
Show Figures

Figure 1

22 pages, 5623 KB  
Article
Lanthanides-Based Nanoparticles Conjugated with Rose Bengal for FRET-Mediated X-Ray-Induced PDT
by Batoul Dhaini, Joël Daouk, Hervé Schohn, Philippe Arnoux, Valérie Jouan-Hureaux, Albert Moussaron, Agnès Hagege, Mathilde Achard, Samir Acherar, Tayssir Hamieh and Céline Frochot
Pharmaceuticals 2025, 18(5), 672; https://doi.org/10.3390/ph18050672 - 1 May 2025
Cited by 1 | Viewed by 1353
Abstract
In order to find a good candidate for Förster Resonance Energy Transfer (FRET)-mediated X-ray-induced photodynamic therapy (X-PDT) for the treatment of cancer, lanthanide (Ln)-based AGuIX nanoparticles (NPs) conjugated with Rose Bengal (RB) as a photosensitizer (PS) were synthesized. X-PDT overcomes the problem of [...] Read more.
In order to find a good candidate for Förster Resonance Energy Transfer (FRET)-mediated X-ray-induced photodynamic therapy (X-PDT) for the treatment of cancer, lanthanide (Ln)-based AGuIX nanoparticles (NPs) conjugated with Rose Bengal (RB) as a photosensitizer (PS) were synthesized. X-PDT overcomes the problem of the poor penetration of visible light into tissues, which limits the efficacy of PDT in the treatment of deep-seated tumors. It is essential to optimize FRET efficiency by maximizing the overlap integral between donor emission and acceptor absorption and lengthening the duration of the donor emission. In this study, we optimized energy transfer between a scintillator (Sc) as a donor and a PS as an acceptor. Terbium (Tb) and Gadolinium (Gd) as Scs and Rose RB as a PS were chosen. The study of energy transfer between Tb, Gd and RB in solution and chelated on AGuIX NPs proved to be FRET-like. RB was conjugated directly onto AGuIX NPs (i.e., AGuIX Ln@RB), and the use of a spacer arm (i.e., AGuIX Ln@spacer arm-RB) increased FRET efficiency. Singlet oxygen production by these NPs was observed under UV–visible illumination and X-ray irradiation. The in vitro bioassay demonstrated 52% cell death of U-251MG derived from human malignant glioblastoma multiforme at a concentration of 1 μM RB after illumination and irradiation (2 Gy, 320 kV, 10 mA, 3 Gy/min at 47 cm). In addition, the RB-coupled NRP-1-targeting peptide (i.e., K(RB)DKPPR) was conjugated onto AGuIX NPs by a thiol-maleimide click chemistry reaction, and an affinity in the nM range was observed. Full article
(This article belongs to the Special Issue Photodynamic Therapy: 3rd Edition)
Show Figures

Graphical abstract

17 pages, 2136 KB  
Article
Radioiodine Exhalation Following Oral I-131 Administration in a Mouse Model
by Klaus Schomäcker, Thomas Fischer, Ferdinand Sudbrock, Daniela Strohe, Sebastian Weber, Beate Zimmermanns, Felix Dietlein, Philipp Krapf, Harald Schicha, Markus Dietlein and Alexander Drzezga
Biomedicines 2025, 13(4), 897; https://doi.org/10.3390/biomedicines13040897 - 8 Apr 2025
Viewed by 1107
Abstract
Background: The exhalation of radioiodine following radioiodine therapy (RIT) presents a challenge in radiation protection, though the mechanisms remain incompletely understood. Previous studies have indicated that radioiodine is predominantly exhaled in an organically bound form in humans. Methods: This study investigates [...] Read more.
Background: The exhalation of radioiodine following radioiodine therapy (RIT) presents a challenge in radiation protection, though the mechanisms remain incompletely understood. Previous studies have indicated that radioiodine is predominantly exhaled in an organically bound form in humans. Methods: This study investigates the chemical composition and exhaled amounts of radioiodine, as well as the impact of thyroid-targeted pharmacological interventions, using a controlled mouse model. Female Balb/c mice (25 g) were administered oral doses of radioiodine (0.1, 1, 2, 10, and 23 MBq per animal) with and without prior treatment using thyroid-blocking agents (stable iodine, perchlorate) or antithyroid drugs (carbimazole). Exhaled radioiodine was collected in metabolic cages, separating chemical forms (aerosolized iodine, elemental iodine, organically bound iodine), and quantified via scintillation counter. Results: The exhaled radioiodine activity was proportional to the administered dose (0.2–0.3%). Thyroid-blocking agents increased exhalation, shifting toward elemental iodine. Antithyroid drugs reduced exhalation but increased aerosol formation, particularly at higher I-131 doses. Organically bound iodine remained the predominant exhaled species in all groups. Conclusions: These results highlight the critical role of the thyroid in radioiodine organification. The blockade of thyroid uptake disrupted the formation of organically bound iodine, suggesting that iodine organification requires passage through the thyroid. Additionally, the results support the hypothesis that iodine metabolism outside the thyroid is less efficient, contributing to the formation of organic iodine species. Radical formation is likely a key factor in generating these volatile iodine species, with radiation-induced iodine and methyl radicals playing a role in their formation. Full article
(This article belongs to the Section Molecular and Translational Medicine)
Show Figures

Figure 1

15 pages, 828 KB  
Article
New Results of the Experiment to Search for Double Beta Decay of 106Cd with Enriched 106CdWO4 Scintillator
by P. Belli, R. Bernabei, F. Cappella, V. Caracciolo, R. Cerulli, F. A. Danevich, A. Incicchitti, D. V. Kasperovych, V. R. Klavdiienko, V. V. Kobychev, A. Leoncini, V. Merlo, O. G. Polischuk and V. I. Tretyak
Universe 2025, 11(4), 123; https://doi.org/10.3390/universe11040123 - 7 Apr 2025
Cited by 1 | Viewed by 810
Abstract
In this article, we present current results of the experiment searching for double beta decay of 106Cd with the help of an enriched 106CdWO4 crystal scintillator in coincidence with two CdWO4 scintillation detectors. The experiment is carried out at [...] Read more.
In this article, we present current results of the experiment searching for double beta decay of 106Cd with the help of an enriched 106CdWO4 crystal scintillator in coincidence with two CdWO4 scintillation detectors. The experiment is carried out at the Gran Sasso underground laboratory of the National Institute for Nuclear Physics (LNGS INFN, Italy). After 1075 days of data-taking, no double-beta effects were observed. New half-life limits have been set for the different modes and channels of double beta processes in 106Cd at the level of limT1/2=10201022 years. Full article
Show Figures

Figure 1

11 pages, 1292 KB  
Article
Design and Simulation of a Muon Detector Using Wavelength-Shifting Fiber Readouts for Border Security
by Anzori Sh. Georgadze
Instruments 2025, 9(1), 1; https://doi.org/10.3390/instruments9010001 - 27 Jan 2025
Cited by 1 | Viewed by 3331
Abstract
Cosmic ray muon tomography is a promising method for the non-invasive inspection of shipping containers and trucks. It leverages the highly penetrating cosmic muons and their interactions with various materials to generate three-dimensional images of large and dense objects, such as inter-modal shipping [...] Read more.
Cosmic ray muon tomography is a promising method for the non-invasive inspection of shipping containers and trucks. It leverages the highly penetrating cosmic muons and their interactions with various materials to generate three-dimensional images of large and dense objects, such as inter-modal shipping containers, which are typically opaque to conventional X-ray radiography techniques. One of the key tasks of customs and border security is verifying shipping container declarations to prevent illegal trafficking, and muon tomography offers a viable solution for this purpose. Common imaging methods using muons rely on data analysis of either muon scattering or absorption–transmission. We design a compact muon tomography system with dimensions of 3 × 3 × 3 m3, consisting of 2D position-sensitive detectors. These detectors include plastic scintillators, wavelength-shifting (WLS) fibers, and SiPMs. Through light transport modeling with GEANT4, we demonstrate that the proposed detector design—featuring 1 m × 1 m scintillator plates with 2 mm2 square-shaped WLS fibers—can achieve a spatial resolution of approximately 0.7–1.0 mm. Through Monte Carlo simulations, we demonstrate that combining muon scattering and absorption data enables the rapid and accurate identification of cargo materials. In a smuggling scenario where tobacco is falsely declared as paper towel rolls, this combined analysis distinguishes the two with 3 σ confidence at a spatial resolution of 1 mm (FWHM) for the muon detector, achieving results within a scanning time of 40 s for a 20-foot shipping container. Full article
Show Figures

Figure 1

15 pages, 5042 KB  
Article
Characterization of kHz Repetition Rate Laser-Driven Electron Beams by an Inhomogeneous Field Dipole Magnet Spectrometer
by Illia Zymak, Marco Favetta, Gabriele Maria Grittani, Carlo Maria Lazzarini, Gianfranco Tassielli, Annika Grenfell, Leonardo Goncalves, Sebastian Lorenz, Vanda Sluková, Filip Vitha, Roberto Versaci, Edwin Chacon-Golcher, Michal Nevrkla, Jiří Šišma, Roman Antipenkov, Václav Šobr, Wojciech Szuba, Theresa Staufer, Florian Grüner, Loredana Lapadula, Ezio Ranieri, Michele Piombino, Nasr A. M. Hafz, Christos Kamperidis, Daniel Papp, Sudipta Mondal, Pavel Bakule and Sergei V. Bulanovadd Show full author list remove Hide full author list
Photonics 2024, 11(12), 1208; https://doi.org/10.3390/photonics11121208 - 23 Dec 2024
Cited by 3 | Viewed by 2482
Abstract
We demonstrate a method to characterize the beam energy, transverse profile, charge, and dose of a pulsed electron beam generated by a 1 kHz TW laser-plasma accelerator. The method is based on imaging with a scintillating screen in an inhomogeneous, orthogonal magnetic field [...] Read more.
We demonstrate a method to characterize the beam energy, transverse profile, charge, and dose of a pulsed electron beam generated by a 1 kHz TW laser-plasma accelerator. The method is based on imaging with a scintillating screen in an inhomogeneous, orthogonal magnetic field produced by a wide-gap magnetic dipole. Numerical simulations were developed to reconstruct the electron beam parameters accurately. The method has been experimentally verified and calibrated using a medical LINAC. The energy measurement accuracy in the 6–20 MeV range is proven to be better than 10%. The radiation dose has been calibrated by a water-equivalent phantom, RW3, showing a linear response of the method within 2% in the 0.05–0.5 mGy/pulse range. Full article
Show Figures

Figure 1

10 pages, 3024 KB  
Article
Characterization of an Inorganic Powder-Based Scintillation Detector Under a UHDR Electron Beam
by Daline Tho and Sam Beddar
Sensors 2024, 24(24), 8064; https://doi.org/10.3390/s24248064 - 18 Dec 2024
Cited by 1 | Viewed by 1195
Abstract
(1) Background: Ultra-high dose rate (UHDR) radiation therapy needs a reliable dosimetry solution and scintillation detectors are promising candidates. In this study, we characterized an inorganic powder-based scintillation detector under a 9 MeV UHDR electron beam. (2) Methods: A mixture of ZnS:Ag powder [...] Read more.
(1) Background: Ultra-high dose rate (UHDR) radiation therapy needs a reliable dosimetry solution and scintillation detectors are promising candidates. In this study, we characterized an inorganic powder-based scintillation detector under a 9 MeV UHDR electron beam. (2) Methods: A mixture of ZnS:Ag powder and optic glue was coupled to an 8 m Eska GH-4001-P polymethyl methacrylate (PMMA) optical fiber. We evaluated the dependence of the detector on dose per pulse (DPP), pulse repetition frequency (PRF), and pulse width (PW). Additionally, we determined the stability and the reproducibility of the detector. (3) Results: The signal ratio between the PMMA clear optical fiber and the ZnS:Ag scintillator was around 210. ZnS:Ag produced a signal yield 54 times greater than that of a BCF-12 plastic scintillator. Signal variation with PRF changes was under 0.5%. The signal was linear to the integrated dose up to the maximum deliverable dose, 180 Gy. The variation in signal was linear to the change in both PW and DPP. Regarding stability, the standard deviation of 10 consecutive irradiations was 0.83%. For the reproducibility, all daily measurements varied within ±1.5%. (4) Conclusions: These findings show that the ZnS:Ag detector can be used for accurate dosimetry with UHDR beams. Full article
(This article belongs to the Special Issue Optical Fiber Sensors in Radiation Environments: 2nd Edition)
Show Figures

Figure 1

12 pages, 3710 KB  
Article
Design and Performance of an InAs Quantum Dot Scintillator with Integrated Photodetector
by Tushar Mahajan, Allan Minns, Vadim Tokranov, Michael Yakimov, Michael Hedges, Pavel Murat and Serge Oktyabrsky
Sensors 2024, 24(22), 7178; https://doi.org/10.3390/s24227178 - 8 Nov 2024
Viewed by 1888
Abstract
A new scintillation material composed of InAs quantum dots (QDs) hosted within a GaAs matrix was developed, and its performance with different types of radiation is evaluated. A methodology for designing an integrated photodetector (PD) with a low defect density and that is [...] Read more.
A new scintillation material composed of InAs quantum dots (QDs) hosted within a GaAs matrix was developed, and its performance with different types of radiation is evaluated. A methodology for designing an integrated photodetector (PD) with a low defect density and that is optically matched to the QD’s emission spectrum is introduced, utilizing an engineered epitaxial InAlGaAs metamorphic buffer layer. The photoluminescence (PL) collection efficiency of the integrated PD is examined using two-dimensional scanning laser excitation. The detector response to 5.5 MeV α-particles and 122 keV photons is presented. Yields of 13 electrons/keV for α-particles and 30–60 electrons/keV for photons were observed. The energy resolution of 12% observed with α-particles was mainly limited by noise- and geometry-related optical losses. The radiation hardness of an InAs QDs hosted within GaAs and a wider band gap AlGaAs ternary alloy was studied under a 1 MeV proton implantation up to a 1014 cm−2 dose. The integrated PL responses were compared to evaluate PL quenching due to non-radiative defects. The QDs embedded in the AlGaAs demonstrated improved radiation hardness compared to QDs in the GaAs matrix and in the InGaAs quantum wells. Full article
Show Figures

Figure 1

8 pages, 1124 KB  
Communication
Light Output Function and Pulse-Shape Discrimination Capability of p-Terphenyl Organic Scintillator in Wide Neutron Energy Range of 1.1 to 19 MeV
by Aleš Jančář, Zdeněk Kopecký, Jiří Čulen, Zdeněk Matěj and Michal Košťál
Instruments 2024, 8(4), 46; https://doi.org/10.3390/instruments8040046 - 22 Oct 2024
Cited by 1 | Viewed by 1611
Abstract
In this work, we studied the light-output properties, efficiency function, as well as the pulse-shape discrimination (PSD) capability of p-Terphenyl scintillator. The selected solid cylindrical scintillation detector has a thickness of 45 mm and a diameter of 45 mm. Recently presented studies of [...] Read more.
In this work, we studied the light-output properties, efficiency function, as well as the pulse-shape discrimination (PSD) capability of p-Terphenyl scintillator. The selected solid cylindrical scintillation detector has a thickness of 45 mm and a diameter of 45 mm. Recently presented studies of light-output functions have only been measured for low-neutron energies. Our motivation has been to determine the light output function for p-Terphenyl scintillator more accurately over a wider neutron energy range. The measurements have been carried out with mono-energetic neutron beams in the wide energy range from 1.1 to 19 MeV. The neutron–gamma spectrometric system which we developed has been used for the measurement. The input analog signal from the detector was digitized with a fast 12-bits analog to digital converter with a sampling frequency of 1 GHz. Measured data from the detector are processed into the gamma and neutron spectra. The accurate light output function for the p-Therphenyl scintillator has been calculated. The pulse-shape discrimination capability, as well as the detection efficiency, of a p-Terphenyl scintillator are lower in comparison with a NE-213 equivalent detector. Full article
Show Figures

Figure 1

Back to TopTop