Sign in to use this feature.

Years

Between: -

Subjects

remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline

Journals

Article Types

Countries / Regions

Search Results (191)

Search Parameters:
Keywords = scintillating light

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
11 pages, 1801 KiB  
Communication
New High Light Yield and Fast Ceramic Scintillator Y3Al2.5Ga2.5O12:Ce, Mg
by Valentina Smyslova, Aliaksei Bondarau, Andrei Fedorov, Elizaveta Borisevich, Ilya Lagutskiy, Petr Karpuyk, Ilia Komendo, Vladimir Kalinov, Vitaly Mechinsky, Vasilii Retivov, Yauheni Talochko, Andrei Vasil’ev and Mikhail Korzhik
Photonics 2025, 12(7), 680; https://doi.org/10.3390/photonics12070680 - 6 Jul 2025
Viewed by 274
Abstract
New scintillation transparent ceramics Y3Al2.5Ga2.5O12:Ce, Mg has been produced and evaluated for the first time. The material possesses a density of 5.17 g/cm3, a highlight yield of 44,000 ph/MeV, and an effective scintillation [...] Read more.
New scintillation transparent ceramics Y3Al2.5Ga2.5O12:Ce, Mg has been produced and evaluated for the first time. The material possesses a density of 5.17 g/cm3, a highlight yield of 44,000 ph/MeV, and an effective scintillation kinetics decay constant of 47 ns. This unique combination of the parameters makes it superior to YAG:Ce. Production of the material does not include tooling from precious materials, and the rate of the crystalline mass production is not limited by the pulling rate of the crystal growth process. It can be quite prospective to upgrade the detection units of a variety of X-ray imaging devices. The mechanism of the scintillation light yield enhancement and kinetics shortening in the material are discussed as well. Full article
Show Figures

Figure 1

28 pages, 9146 KiB  
Review
Nanoscale Porphyrin-Based Metal–Organic Frameworks for Enhanced Radiotherapy–Radiodynamic Therapy: A Comprehensive Review
by Bin Gong, Qiuyun Zhang, Yijie Qu, Xiaohua Zheng and Weiqi Wang
Pharmaceutics 2025, 17(7), 883; https://doi.org/10.3390/pharmaceutics17070883 - 4 Jul 2025
Viewed by 513
Abstract
The phototherapeutic applications of porphyrin-based nanoscale metal–organic frameworks (nMOFs) are limited by the poor penetration of conventional excitation light sources into biological tissues. Radiodynamic therapy (RDT), which directly excites photosensitizers using X-rays, can overcome the issue of tissue penetration. However, RDT faces the [...] Read more.
The phototherapeutic applications of porphyrin-based nanoscale metal–organic frameworks (nMOFs) are limited by the poor penetration of conventional excitation light sources into biological tissues. Radiodynamic therapy (RDT), which directly excites photosensitizers using X-rays, can overcome the issue of tissue penetration. However, RDT faces the problems of low energy conversion efficiency, requiring a relatively high radiation dose, and the potential to cause damage to normal tissues. Researchers have found that by using some metals with high atomic numbers (high Z) as X-ray scintillators and coordinating them with porphyrin photosensitizers to form MOF materials, the excellent antitumor effect of radiotherapy (RT) and RDT can be achieved under low-dose X-ray irradiation, which can not only effectively avoid the penetration limitations of light excitation methods but also eliminate the defect issues associated with directly using X-rays to excite photosensitizers. This review summarizes the relevant research work in recent years, in which researchers have used metal ions with high Z, such as Hf4+, Th4+, Ta5+, and Bi3+, in coordination with carboxyl porphyrins to form MOF materials for combined RT and RDT toward various cancer cells. This review compares the therapeutic effects and advantages of using different high-Z metals and introduces the application of the heavy atom effect. Furthermore, it explores the introduction of a chemodynamic therapy (CDT) mechanism through iron coordination at the porphyrin center, along with optimization strategies such as oxygen delivery using hemoglobin to enhance the efficacy of these MOFs as radiosensitizers. This review also summarizes the potential of these materials in preclinical applications and highlights the current challenges they face. It is expected that the summary and prospects outlined in this review can further promote preclinical biomedical research into and the development of porphyrin-based nMOFs. Full article
(This article belongs to the Special Issue Advanced Nanotechnology for Combination Therapy and Diagnosis)
Show Figures

Graphical abstract

18 pages, 2524 KiB  
Article
Measuring Optical Scattering in Relation to Coatings on Crystalline X-Ray Scintillator Screens
by Matthias Diez and Simon Zabler
Crystals 2025, 15(7), 605; https://doi.org/10.3390/cryst15070605 - 27 Jun 2025
Viewed by 325
Abstract
Scattered light makes up a significant amount of recorded intensities during tomographic imaging, thereby leading to severe misinterpretation and artifacts in the reconstructed volume images. Correcting artificial intensities that stem from scattered light, therefore, is of primary interest and demands quantitative measurements. While [...] Read more.
Scattered light makes up a significant amount of recorded intensities during tomographic imaging, thereby leading to severe misinterpretation and artifacts in the reconstructed volume images. Correcting artificial intensities that stem from scattered light, therefore, is of primary interest and demands quantitative measurements. While numerous methods have been developed to reduce X-ray scattering artifacts, fewer methods deal with optical scattering. In this study, a measurement method for determining optical scattering in scintillators is presented with the aim of further developing correction algorithms. A theoretical model based on internal multiple reflections was developed for this purpose. This model assumes an additive exponential kernel with a certain scattering length to the system’s point spread function. This assumption was confirmed, and the scatter length was estimated from three new different kinds of experiments (hgap, rect, and LSF) on the BM18 beamline of the European synchrotron. The experiments further revealed significant differences in scattering proportion and length when different coatings are applied to the front and back faces of crystalline LuAG scintillators. Anti-reflective coatings on the backside show an effect of reducing the scattering magnitude while reflective coatings on the front side increase the proportion of the unscattered signal and, thus, show proportionally less scattering than black coating or no front coating. In particular, roughened black coating is found to worsen optical scattering. In summary, our results indicate that a combination of reflective (front) and anti-reflective (back) coatings yields the least optical scattering and, hence, the best image quality. Full article
(This article belongs to the Section Crystal Engineering)
Show Figures

Figure 1

12 pages, 1285 KiB  
Article
Performance Analysis of Space-to-Ground Downlink for Polarization Shift Keying Optical Communications with a Gaussian-Schell Model Beam
by Jiajie Wu, Yuwei Zhang, Qingyan Li, Siyuan Yu and Jianjie Yu
Photonics 2025, 12(7), 643; https://doi.org/10.3390/photonics12070643 - 24 Jun 2025
Viewed by 229
Abstract
Free-space optical communication has emerged as a pivotal technology for space-to-ground downlinks; however, signal degradation caused by atmospheric turbulence continues to pose a significant challenge. In this study, a model for the polarization transmission characteristics of a Gaussian-Schell model (GSM) beam in downlink [...] Read more.
Free-space optical communication has emerged as a pivotal technology for space-to-ground downlinks; however, signal degradation caused by atmospheric turbulence continues to pose a significant challenge. In this study, a model for the polarization transmission characteristics of a Gaussian-Schell model (GSM) beam in downlink was established, and conditions sufficient for maintaining the polarization transmission characteristics were derived. The impact of the source spatial coherence on the performance of optical communication systems using circular polarization shift keying (CPolSK) modulation was investigated. Additionally, models for the probability density distribution and scintillation index of the optical intensity under atmospheric turbulence were developed along with a bit error rate model for the optical communication system. The effects of the laser spatial coherence on these models were also analyzed. The results indicate that the optimal performance in the turbulent downlink is achieved with fully coherent light, where the GSM-beam-based CPolSK-modulated system demonstrates a reduction of 1.51 dB in the required power compared to that of an on–off keying system. The implications of this study suggest that optimizing spatial coherence could significantly enhance the reliability of space-to-ground communication systems under atmospheric disturbances. Full article
Show Figures

Figure 1

12 pages, 2965 KiB  
Article
Tailoring Luminescence and Scintillation Properties of Tb3+-Doped LuYAGG Single Crystals for High-Performance Radiation Detection
by Prapon Lertloypanyachai, Prom Kantuptim, Eakapon Kaewnuam, Toshiaki Kunikata, Yusuke Endo, Weerapong Chewpraditkul, Takumi Kato, Daisuke Nakauchi, Noriaki Kawaguchi, Kenichi Watanabe and Takayuki Yanagida
Appl. Sci. 2025, 15(12), 6888; https://doi.org/10.3390/app15126888 - 18 Jun 2025
Viewed by 398
Abstract
In this study, Lu2.5Y0.5(Al2.5Ga2.5)O12 (LuYAGG) single-crystal scintillators doped with terbium ions (Tb3+) at concentrations of 0.5, 1, 5, and 10 mol% were successfully synthesized using the floating zone method. The structural, optical, [...] Read more.
In this study, Lu2.5Y0.5(Al2.5Ga2.5)O12 (LuYAGG) single-crystal scintillators doped with terbium ions (Tb3+) at concentrations of 0.5, 1, 5, and 10 mol% were successfully synthesized using the floating zone method. The structural, optical, photoluminescence (PL), and scintillation properties of the Tb3+-doped crystals were systematically investigated with a focus on their potential for high-performance scintillator applications. X-ray diffraction (XRD) confirmed the formation of a pure garnet phase without any secondary phases, indicating the successful incorporation of Tb3+ into the LuYAGG lattice. Optical transmittance spectra revealed high transparency in the visible range. Photoluminescence measurements showed characteristic Tb3+ emission peaks, with the strongest green emission observed from the 5D47F5 transition, particularly for the 5 mol% sample. The PL decay curves further confirmed that this concentration offers a favorable balance between radiative efficiency and minimal non-radiative losses. Under γ-ray excitation, the 5 mol% Tb3+-doped crystal exhibited the highest light yield, surpassing the performance of other concentrations and even outperforming Bi4Ge3O12 (BGO) in relative comparison, with an estimated yield of approximately 60,000 photons/MeV. Scintillation decay time analysis revealed that the 5 mol% sample also possessed the fastest decay component, indicating its superior capability for radiation detection. Although 10 mol% Tb3+ still showed good performance, slight quenching effects were observed, while lower concentrations (0.5 and 1 mol%) suffered from longer decay and lower emission efficiency due to limited activator density. These findings clearly identify with 5 mol% Tb3+ as the optimal dopant level in LuYAGG single crystals, offering a synergistic combination of high light yield and excellent optical transparency. This work highlights the strong potential of LuYAGG:Tb3+ as a promising candidate for the next-generation scintillator materials used in medical imaging, security scanning, and high-energy physics applications. Full article
(This article belongs to the Section Materials Science and Engineering)
Show Figures

Figure 1

15 pages, 5363 KiB  
Article
Compact and Handheld SiPM-Based Gamma Camera for Radio-Guided Surgery and Medical Imaging
by Fabio Acerbi, Aramis Raiola, Cyril Alispach, Hossein Arabi, Habib Zaidi, Alberto Gola and Domenico Della Volpe
Instruments 2025, 9(2), 14; https://doi.org/10.3390/instruments9020014 - 15 Jun 2025
Viewed by 570
Abstract
In the continuous pursuit of minimally invasive interventions while ensuring a radical excision of lesions, Radio-Guided Surgery (RGS) has been for years the standard for image-guided surgery procedures, such as the Sentinel Lymph Node biopsy (SLN), Radio-guided Seed Localization (RSL), etc. In RGS, [...] Read more.
In the continuous pursuit of minimally invasive interventions while ensuring a radical excision of lesions, Radio-Guided Surgery (RGS) has been for years the standard for image-guided surgery procedures, such as the Sentinel Lymph Node biopsy (SLN), Radio-guided Seed Localization (RSL), etc. In RGS, the lesion has to be identified precisely, in terms of position and extension. In such a context, going beyond the current one-point probes, introducing portable but high-resolution cameras, handholdable by the surgeon, would be highly beneficial. We developed and tested a novel compact, low-power, handheld gamma camera for radio-guided surgery. This is based on a particular position-sensitive Silicon Photomultiplier (SiPM) technology—the FBK linearly graded SiPM (LG-SiPM). Within the camera, the photodetector is made up of a 3 × 3 array of 10 × 10 mm2 SiPM chips having a total area of more than 30 × 30 mm2. This is coupled with a pixelated scintillator and a parallel-hole collimator. With the LG-SiPM technology, it is possible to significantly reduce the number of readout channels to just eight, simplifying the complexity and lowering the power consumption of the readout electronics while still preserving a good position resolution. The novel gamma camera is light (weight), and it is made to be a fully stand-alone system, therefore featuring wireless communication, battery power, and wireless recharge capabilities. We designed, simulated (electrically), and tested (functionally) the first prototypes of the novel gamma camera. We characterized the intrinsic position resolution (tested with pulsed light) as being ~200 µm, and the sensitivity and resolution when detecting gamma rays from Tc-99m source measured between 134 and 481 cps/MBq and as good as 1.4–1.9 mm, respectively. Full article
Show Figures

Figure 1

15 pages, 1871 KiB  
Article
NIR-Emitting Scintillators Based on CsI Single Crystals
by Dmitriy Sofich, Veronika Gavrilenko, Viktorija Pankratova, Vladimir Pankratov, Ekaterina Kaneva and Roman Shendrik
Crystals 2025, 15(6), 489; https://doi.org/10.3390/cryst15060489 - 22 May 2025
Viewed by 439
Abstract
The development of efficient scintillators emitting in the red and/or infrared spectral range represents an important scientific challenge, as such materials could find numerous practical applications. This work studies newly grown CsI:Yb,Sm and CsI:Eu,Sm single crystals demonstrating red and infrared luminescence. We measured [...] Read more.
The development of efficient scintillators emitting in the red and/or infrared spectral range represents an important scientific challenge, as such materials could find numerous practical applications. This work studies newly grown CsI:Yb,Sm and CsI:Eu,Sm single crystals demonstrating red and infrared luminescence. We measured luminescence spectra in the visible and near-IR range, excitation spectra across visible, UV, VUV, and X-ray ranges, Raman spectra, and thermoluminescence spectra. The results show that divalent europium and ytterbium ions can efficiently transfer excitation to samarium ions. The light output of the obtained crystals under X-ray excitation was roughly estimated from the X-ray luminescence spectra, with expected values of 37,000 photons/MeV for CsI:Yb,Sm and 40,000 photons/MeV for CsI:Eu,Sm. Full article
(This article belongs to the Section Crystal Engineering)
Show Figures

Figure 1

10 pages, 2270 KiB  
Article
Highly Luminescent and Scintillating Hybrid Halide of (C13H25N)2[MnBr4] Enabled by Rigid Cation
by Renfu Li, Lulu Jiang, Qinghua Zou, Jianlong Bai, Lingkun Wu, Jianrong Li and Jinsheng Liao
Molecules 2025, 30(10), 2157; https://doi.org/10.3390/molecules30102157 - 14 May 2025
Viewed by 443
Abstract
Organic–inorganic hybrid manganese halides (OIMnHs) have attracted significant attention in the field of optoelectronics due to their outstanding optical properties and low toxicity. However, the development of crystalline compounds with scintillating properties and high light yield remains a significant challenge. In this study, [...] Read more.
Organic–inorganic hybrid manganese halides (OIMnHs) have attracted significant attention in the field of optoelectronics due to their outstanding optical properties and low toxicity. However, the development of crystalline compounds with scintillating properties and high light yield remains a significant challenge. In this study, a simple solution method was employed to successfully synthesize a new zero-dimensional (0-D) scintillation crystal, (C13H25N)2[MnBr4] (C13H25N = trimethyladamantan-1-aminium). The introduction of bulky and rigid organic cations not only spatially isolates the [MnBr4]2− tetrahedrons but also effectively expands the Mn···Mn distance, thereby suppressing the concentration quenching and self-absorption effects. This structural design achieves a high photoluminescence quantum yield of about 63.8% at room temperature and a remarkable light yield of 44,300 photons MeV−1. After multiple irradiation cycles, the material retains its stable radiative characteristics. This work highlights the key role of rigid cation engineering in improving luminescence efficiency and scintillation performance and provides new ideas for designing efficient and nontoxic OIMnH-based scintillators. Full article
(This article belongs to the Special Issue Emerging Topics in Luminescent Materials)
Show Figures

Graphical abstract

22 pages, 5623 KiB  
Article
Lanthanides-Based Nanoparticles Conjugated with Rose Bengal for FRET-Mediated X-Ray-Induced PDT
by Batoul Dhaini, Joël Daouk, Hervé Schohn, Philippe Arnoux, Valérie Jouan-Hureaux, Albert Moussaron, Agnès Hagege, Mathilde Achard, Samir Acherar, Tayssir Hamieh and Céline Frochot
Pharmaceuticals 2025, 18(5), 672; https://doi.org/10.3390/ph18050672 - 1 May 2025
Viewed by 660
Abstract
In order to find a good candidate for Förster Resonance Energy Transfer (FRET)-mediated X-ray-induced photodynamic therapy (X-PDT) for the treatment of cancer, lanthanide (Ln)-based AGuIX nanoparticles (NPs) conjugated with Rose Bengal (RB) as a photosensitizer (PS) were synthesized. X-PDT overcomes the problem of [...] Read more.
In order to find a good candidate for Förster Resonance Energy Transfer (FRET)-mediated X-ray-induced photodynamic therapy (X-PDT) for the treatment of cancer, lanthanide (Ln)-based AGuIX nanoparticles (NPs) conjugated with Rose Bengal (RB) as a photosensitizer (PS) were synthesized. X-PDT overcomes the problem of the poor penetration of visible light into tissues, which limits the efficacy of PDT in the treatment of deep-seated tumors. It is essential to optimize FRET efficiency by maximizing the overlap integral between donor emission and acceptor absorption and lengthening the duration of the donor emission. In this study, we optimized energy transfer between a scintillator (Sc) as a donor and a PS as an acceptor. Terbium (Tb) and Gadolinium (Gd) as Scs and Rose RB as a PS were chosen. The study of energy transfer between Tb, Gd and RB in solution and chelated on AGuIX NPs proved to be FRET-like. RB was conjugated directly onto AGuIX NPs (i.e., AGuIX Ln@RB), and the use of a spacer arm (i.e., AGuIX Ln@spacer arm-RB) increased FRET efficiency. Singlet oxygen production by these NPs was observed under UV–visible illumination and X-ray irradiation. The in vitro bioassay demonstrated 52% cell death of U-251MG derived from human malignant glioblastoma multiforme at a concentration of 1 μM RB after illumination and irradiation (2 Gy, 320 kV, 10 mA, 3 Gy/min at 47 cm). In addition, the RB-coupled NRP-1-targeting peptide (i.e., K(RB)DKPPR) was conjugated onto AGuIX NPs by a thiol-maleimide click chemistry reaction, and an affinity in the nM range was observed. Full article
(This article belongs to the Special Issue Photodynamic Therapy: 3rd Edition)
Show Figures

Graphical abstract

10 pages, 1391 KiB  
Article
Luminescence and Scintillation Properties of YAl3(BO3)4 Single Crystal for Thermal Neutron Detection
by Yutaka Fujimoto, Masanori Koshimizu, Hiroki Kawamoto, Kenichi Watanabe, Akio Miyamoto and Keisuke Asai
Crystals 2025, 15(4), 357; https://doi.org/10.3390/cryst15040357 - 12 Apr 2025
Viewed by 458
Abstract
A single crystal of YAl3(BO3)4 was grown using the top-seeded solution growth method. The vacuum ultraviolet (VUV) excitation spectrum, monitored at the emission wavelength of 312 and 372 nm, showed a narrow excitation band at around 162 nm, [...] Read more.
A single crystal of YAl3(BO3)4 was grown using the top-seeded solution growth method. The vacuum ultraviolet (VUV) excitation spectrum, monitored at the emission wavelength of 312 and 372 nm, showed a narrow excitation band at around 162 nm, which is located near the absorption edge of the YAl3(BO3)4 host. Upon VUV excitation at 162 nm, the characteristic self-trapped exciton (STE) emission bands were observed at 312 and 372 nm. The X-ray excited scintillation spectrum shows a broad emission band peaking at 310 nm with a weak shoulder band at around 375 nm, which is consistent with photoluminescence, and can thus be assigned to the STE emission. The scintillation light yield under irradiation at a 252Cf-thermal neutron reached 2700 photons/thermal neutron. Full article
(This article belongs to the Section Inorganic Crystalline Materials)
Show Figures

Figure 1

19 pages, 1620 KiB  
Article
Underwater Coherent Optical Wireless Communications with Electronic Beam Steering and Turbulence Compensation Using Adaptive Optics and Aperture Averaging
by Ali Derakhshandeh, Peter A. Hoeher and Stephan Pachnicke
Photonics 2025, 12(3), 268; https://doi.org/10.3390/photonics12030268 - 14 Mar 2025
Viewed by 901
Abstract
A novel approach to underwater optical wireless coherent communications using liquid crystal spatial light modulators (LC-SLMs) and an aperture averaging lens, in combination with optical phased-array (OPA) antennas, is presented. A comprehensive channel model that includes a wide range of underwater properties, including [...] Read more.
A novel approach to underwater optical wireless coherent communications using liquid crystal spatial light modulators (LC-SLMs) and an aperture averaging lens, in combination with optical phased-array (OPA) antennas, is presented. A comprehensive channel model that includes a wide range of underwater properties, including absorption, scattering, and turbulence effects, is employed to simulate the underwater optical wireless communication (UOWC) system in a realistic manner. The proposed system concept utilizes aperture averaging and adaptive optics techniques to mitigate the degrading effects of turbulence. Additionally, OPA antennas are integrated into the system to provide electronic beam steering capabilities, facilitating precise pointing, acquisition, and tracking (PAT) between mobile underwater vehicles. This integration enables high-speed and reliable communication links by maintaining optimal alignment. The numerical results show that under strong turbulence, our combined turbulence-compensation approach (LC-SLM plus aperture averaging) can extend the communication range by approximately threefold compared to a baseline system without compensation. For instance, at a soft-decision FEC threshold of 1.25×102, the maximum achievable link distance increases from around 10m to over 30m. Moreover, the scintillation index is reduced by more than 90%, and the bit error rate (BER) improves. Full article
Show Figures

Figure 1

16 pages, 7837 KiB  
Article
Light Output Response of a Barium Fluoride (BaF2) Inorganic Scintillator Under X-Ray Radiation
by Vasileios Ntoupis, Christos Michail, Nektarios Kalyvas, Athanasios Bakas, Ioannis Kandarakis, George Fountos and Ioannis Valais
Inorganics 2025, 13(3), 83; https://doi.org/10.3390/inorganics13030083 - 13 Mar 2025
Viewed by 785
Abstract
In this study, the luminescence efficiency of a crystal-form barium fluoride (BaF2) inorganic scintillator was assessed for medical imaging applications. For the experiments, we used a typical medical X-ray tube (50–140 kVp) for estimating the absolute luminescence efficiency (AE). Furthermore, we [...] Read more.
In this study, the luminescence efficiency of a crystal-form barium fluoride (BaF2) inorganic scintillator was assessed for medical imaging applications. For the experiments, we used a typical medical X-ray tube (50–140 kVp) for estimating the absolute luminescence efficiency (AE). Furthermore, we examined the spectral matching of the inorganic scintillator with a series of optical detectors. BaF2 showed a higher AE than cerium fluoride (CeF3), comparable to that of commercially available bismuth germanate (Bi4Ge3O12-BGO), but lower than that of the gadolinium orthosilicate (Gd2SiO5:Ce-GSO:Ce) inorganic scintillator. The maximum AE of BaF2 was 2.36 efficiency units (EU is the S.I. equivalent μWm−2/(mR/s) at 140 kVp, which is higher than that of the corresponding fluoride-based CeF3 (0.8334 EU)) at the same X-ray energy. GSO:Ce and BGO crystals, which are often integrated in commercial positron emission tomography (PET) scanners, had AE values of 7.76 and 3.41, respectively. The emission maximum (~310 nm) of BaF2 is adequate for coupling with flat-panel position-sensitive (PS) photomultipliers (PMTs) and various photocathodes. The luminescence efficiency results of BaF2 were comparable to those of BGO; thus, it could possibly be used in medical imaging modalities, considering its significantly lower cost. Full article
Show Figures

Graphical abstract

8 pages, 8051 KiB  
Article
Performance of the ICARUS Trigger System at the Booster and NuMI Neutrino Beams
by Riccardo Triozzi
Particles 2025, 8(1), 22; https://doi.org/10.3390/particles8010022 - 3 Mar 2025
Viewed by 565
Abstract
The ICARUS-T600 liquid argon time projection chamber detector takes data at a shallow depth as the far detector of the Short Baseline Neutrino program at Fermilab, searching for sterile neutrinos with the Booster and Main Injector neutrino beams. The ICARUS trigger system exploits [...] Read more.
The ICARUS-T600 liquid argon time projection chamber detector takes data at a shallow depth as the far detector of the Short Baseline Neutrino program at Fermilab, searching for sterile neutrinos with the Booster and Main Injector neutrino beams. The ICARUS trigger system exploits the temporal coincidence of the beams with scintillation light signals detected by 360 photo-multiplier tubes in limited TPC regions. The trigger efficiency measurement leverages cosmic rays collected without any scintillation light requirement, with timing from an external cosmic ray tagger system. The efficiency measured with stopping muons roughly saturates at Eμ∼300 MeV, covering most of the expected energy range of charged-current neutrino interactions. For the latest ICARUS physics runs, special “adder” boards performing the analog sum of light signals were introduced as a complementary trigger to possibly recover low-energy neutrino interactions. Full article
Show Figures

Figure 1

10 pages, 2660 KiB  
Article
Crystal Growth and Energy Transfer Study in Ce3+ and Pr3+ Co-Doped Lu2Si2O7
by Yuka Abe, Takahiko Horiai, Yuui Yokota, Masao Yoshino, Rikito Murakami, Takashi Hanada, Akihiro Yamaji, Hiroki Sato, Yuji Ohashi, Shunsuke Kurosawa, Kei Kamada and Akira Yoshikawa
Crystals 2025, 15(3), 202; https://doi.org/10.3390/cryst15030202 - 20 Feb 2025
Viewed by 533
Abstract
Ce-doped Lu2Si2O7 has a high density, high luminescence efficiency even at high temperatures, and a high effective atomic number, making it a promising candidate for use as a radiation detector in medical devices and resource exploration equipment. In [...] Read more.
Ce-doped Lu2Si2O7 has a high density, high luminescence efficiency even at high temperatures, and a high effective atomic number, making it a promising candidate for use as a radiation detector in medical devices and resource exploration equipment. In this study, we grow and characterize Pr3+ and Ce3+-doped Lu2Si2O7 single crystals by systematically varying the Ce3+ to Pr3+ ratio to further improve scintillation properties. The optical characterization results show a bidirectional energy transfer: from the Pr3+ 5d levels to the Ce3+ 5d levels and from the Ce3+ 5d levels to the Pr3+ 4f levels. Consistently with this result, the PL decay time of emission from the Pr3+ 5d–4f transition tends to become faster as the Ce3+/Pr3+ ratio increases, due to the energy transfer from the Pr3+ 5d levels to the Ce3+ 5d levels. Additionally, (Ce0.0022 Pr0.0016 Lu0.9962)2Si2O7 exhibits a high light yield comparable to Ce-doped Lu2Si2O7 and a slightly faster decay time than Ce-doped Lu2Si2O7. Full article
(This article belongs to the Special Issue Growth and Properties of Novel Scintillator Crystals)
Show Figures

Figure 1

11 pages, 1292 KiB  
Article
Design and Simulation of a Muon Detector Using Wavelength-Shifting Fiber Readouts for Border Security
by Anzori Sh. Georgadze
Instruments 2025, 9(1), 1; https://doi.org/10.3390/instruments9010001 - 27 Jan 2025
Viewed by 2052
Abstract
Cosmic ray muon tomography is a promising method for the non-invasive inspection of shipping containers and trucks. It leverages the highly penetrating cosmic muons and their interactions with various materials to generate three-dimensional images of large and dense objects, such as inter-modal shipping [...] Read more.
Cosmic ray muon tomography is a promising method for the non-invasive inspection of shipping containers and trucks. It leverages the highly penetrating cosmic muons and their interactions with various materials to generate three-dimensional images of large and dense objects, such as inter-modal shipping containers, which are typically opaque to conventional X-ray radiography techniques. One of the key tasks of customs and border security is verifying shipping container declarations to prevent illegal trafficking, and muon tomography offers a viable solution for this purpose. Common imaging methods using muons rely on data analysis of either muon scattering or absorption–transmission. We design a compact muon tomography system with dimensions of 3 × 3 × 3 m3, consisting of 2D position-sensitive detectors. These detectors include plastic scintillators, wavelength-shifting (WLS) fibers, and SiPMs. Through light transport modeling with GEANT4, we demonstrate that the proposed detector design—featuring 1 m × 1 m scintillator plates with 2 mm2 square-shaped WLS fibers—can achieve a spatial resolution of approximately 0.7–1.0 mm. Through Monte Carlo simulations, we demonstrate that combining muon scattering and absorption data enables the rapid and accurate identification of cargo materials. In a smuggling scenario where tobacco is falsely declared as paper towel rolls, this combined analysis distinguishes the two with 3 σ confidence at a spatial resolution of 1 mm (FWHM) for the muon detector, achieving results within a scanning time of 40 s for a 20-foot shipping container. Full article
Show Figures

Figure 1

Back to TopTop