Sign in to use this feature.

Years

Between: -

Subjects

remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline

Journals

remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline

Article Types

Countries / Regions

remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline

Search Results (403)

Search Parameters:
Keywords = roof strategies

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
36 pages, 5657 KiB  
Article
Modeling of Temperature and Moisture Dynamics in Corn Storage Silos with and Without Aeration Periods in Three Dimensions
by F. I. Molina-Herrera, H. Jiménez-Islas, M. A. Sandoval-Hernández, N. E. Maldonado-Sierra, C. Domínguez Campos, L. Jarquín Enríquez, F. J. Mondragón Rojas and N. L. Flores-Martínez
ChemEngineering 2025, 9(4), 89; https://doi.org/10.3390/chemengineering9040089 - 15 Aug 2025
Viewed by 30
Abstract
This study analyzes the dynamics of temperature and moisture in a cylindrical silo with a conical roof and floor used for storing corn in the Bajío region of Mexico, considering conditions both with and without aeration. The model incorporates external temperature fluctuations, solar [...] Read more.
This study analyzes the dynamics of temperature and moisture in a cylindrical silo with a conical roof and floor used for storing corn in the Bajío region of Mexico, considering conditions both with and without aeration. The model incorporates external temperature fluctuations, solar radiation, grain moisture equilibrium with air humidity through the sorption isotherm (water activity), and grain respiration to simulate real storage conditions. The model is based on continuity, momentum, energy, and moisture conservation equations in porous media. This model was solved using the finite element method (FEM) to evaluate temperature and interstitial humidity variations during January and May, representing cold and warm environmental conditions, respectively. The simulations show that, without aeration, grain temperature progressively accumulates in the center and bottom region of the silo, reaching critical values for safe storage. In January, the low ambient temperature favors the natural dissipation of heat. In contrast, in May, the combination of high ambient temperatures and solar radiation intensifies thermal accumulation, increasing the risk of grain deterioration. However, implementing aeration periods allowed for a reduction in the silo’s internal temperature, achieving more homogeneous cooling and reducing the threats of mold and insect proliferation. For January, an airflow rate of 0.15 m3/(min·ton) was optimal for maintaining the temperature within the safe storage range (≤17 °C). In contrast, in May, neither this airflow rate nor the accumulation of 120 h of aeration was sufficient to achieve optimal storage temperatures. This indicates that, under warm conditions, the aeration strategy needs to be reconsidered, assessing whether a higher airflow rate, longer periods, or a combination of both could improve heat dissipation. The results also show that interstitial relative humidity remains stable with nocturnal aeration, minimizing moisture absorption in January and preventing excessive drying in May. However, it was identified that aeration period management must be adaptive, taking environmental conditions into account to avoid issues such as re-wetting or excessive grain drying. Full article
Show Figures

Figure 1

25 pages, 1477 KiB  
Article
A Cost Benefit Analysis of Vehicle-to-Grid (V2G) Considering Battery Degradation Under the ACOPF-Based DLMP Framework
by Joseph Stekli, Abhijith Ravi and Umit Cali
Smart Cities 2025, 8(4), 138; https://doi.org/10.3390/smartcities8040138 - 14 Aug 2025
Viewed by 110
Abstract
This paper seeks to provide a cost benefit analysis of the implementation of a vehicle-to-grid (V2G) charging strategy relative to a smart charging (V1G) strategy from the perspective of an individual electric vehicle (EV) owner with and without solar photovoltaics (PV) located on [...] Read more.
This paper seeks to provide a cost benefit analysis of the implementation of a vehicle-to-grid (V2G) charging strategy relative to a smart charging (V1G) strategy from the perspective of an individual electric vehicle (EV) owner with and without solar photovoltaics (PV) located on their roof. This work utilizes a novel AC optimized power flow model (ACOPF) to produce distributed location marginal prices (DLMP) on a modified IEEE-33 node network and uses a complete set of real-world costs and benefits to perform this analysis. Costs, in the form of the addition of a bi-directional charger and the increased vehicle depreciation incurred by a V2G strategy, are calculated using modern reference sources. This produces a more true-to-life comparison of the V1G and V2G strategies from the frame of reference of EV owners, rather than system operators, with parameterization of EV penetration levels performed to look at how the choice of strategy may change over time. Counter to much of the existing literature, when the analysis is performed in this manner it is found that the benefits of implementing a V2G strategy in the U.S.—given current compensation schemes—do not outweigh the incurred costs to the vehicle owner. This result helps explain the gap in findings between the existing literature—which typically finds that a V2G strategy should be favored—and the real world, where V2G is rarely employed by EV owners. Full article
Show Figures

Figure 1

23 pages, 5418 KiB  
Article
Optimal Roof Strategy for Mitigating Urban Heat Island in Hot Arid Climates: Simulation and Python-Based Multi-Criteria Decision Analysis
by Rehab Alaa, Amira Elbalazi and Walaa S.E. Ismaeel
Urban Sci. 2025, 9(8), 310; https://doi.org/10.3390/urbansci9080310 - 8 Aug 2025
Viewed by 460
Abstract
This study adopts a multi-scale, simulation-driven approach to evaluate the performance of different passive roof types in mitigating Urban Heat Island (UHI) in hot arid climate. A comparative analysis was performed for selected roof types; green, pond, cool, and dark roofs. At the [...] Read more.
This study adopts a multi-scale, simulation-driven approach to evaluate the performance of different passive roof types in mitigating Urban Heat Island (UHI) in hot arid climate. A comparative analysis was performed for selected roof types; green, pond, cool, and dark roofs. At the urban scale, ENVI-met v5.7.1 was employed to simulate microclimatic impacts, including Mean Radiant Temperature (MRT) at the pedestrian street level (1.4 m) and above building canopy level (25 m). The results revealed that green roofs were the most effective in mitigating UHI on the urban scale, reducing MRT by 1.83 °C at the pedestrian level and by 3.5 °C at the above canopy level. Surprisingly, dark roofs also performed well, with MRT reductions of 1.81 °C and 3.5 °C, respectively, outperforming pond roofs, which showed reductions of 1.80 °C and 0.31 °C. While cool roofs effectively reduced MRT at the pedestrian level by 1.80 °C, they had adverse effect at the canopy level, increasing MRT by 15.58 °C. At the building scale, Design Builder v7.3.1, coupled with Energy Plus, was used to assess indoor thermal and energy performance. Pond and cool roofs reduced operative temperature by 0.08 °C and 0.07 °C, respectively, followed by green roofs, with a 0.05 °C reduction, while dark roofs increased it by 0.07 °C. In terms of energy performance, green roofs yielded the greatest benefit, reducing cooling load by 3.3%, followed by pond roofs, with a 1.32% reduction; cool roofs showed negligible reduction, while dark roofs increased it by 1.2%. Finally, a Python-based Multi criteria Decision Making (MCDM) analytical framework integrated these findings with additional factors to optimize thermal comfort, environmental impact, sustainability, and feasibility and rank strategies accordingly. The analysis identified green roofs as the optimal solution, followed by pond roofs and then cool roofs tied with the base case, leaving dark roofs as the least favorable strategy. This study’s key contribution lies in its integrated simulation–decision analysis methodology, which bridges urban climatology and building performance to provide actionable insights for sustainable urban design. By validating green roofs as the most effective passive strategy in hot arid regions, this work aids policymakers and planners in prioritizing interventions that support climate-resilient urbanization. Full article
Show Figures

Figure 1

16 pages, 3766 KiB  
Article
Evaluation of Energy and CO2 Reduction Through Envelope Retrofitting: A Case Study of a Public Building in South Korea Conducted Using Utility Billing Data
by Hansol Lee and Gyeong-Seok Choi
Energies 2025, 18(15), 4129; https://doi.org/10.3390/en18154129 - 4 Aug 2025
Viewed by 338
Abstract
This study empirically evaluates the energy and carbon reduction effects of an envelope retrofit applied to an aging public building in South Korea. Unlike previous studies that primarily relied on simulation-based analyses, this work fills the empirical research gap by using actual utility [...] Read more.
This study empirically evaluates the energy and carbon reduction effects of an envelope retrofit applied to an aging public building in South Korea. Unlike previous studies that primarily relied on simulation-based analyses, this work fills the empirical research gap by using actual utility billing data collected over one pre-retrofit year (2019) and two post-retrofit years (2023–2024). The retrofit included improvements to exterior walls, roofs, and windows, aiming to enhance thermal insulation and airtightness. The analysis revealed that monthly electricity consumption was reduced by 14.7% in 2023 and 8.0% in 2024 compared to that in the baseline year, with corresponding decreases in electricity costs and carbon dioxide emissions. Seasonal variations were evident: energy savings were significant in the winter due to reduced heating demand, while cooling energy use slightly increased in the summer, likely due to diminished solar heat gains resulting from improved insulation. By addressing both heating and cooling impacts, this study offers practical insights into the trade-offs of envelope retrofitting. The findings contribute to the body of knowledge by demonstrating the real-world performance of retrofit technologies and providing data-driven evidence that can inform policies and strategies for improving energy efficiency in public buildings. Full article
Show Figures

Figure 1

28 pages, 2566 KiB  
Article
Simulating Effectiveness of Low Impact Development (LID) for Different Building Densities in the Face of Climate Change Using a Hydrologic-Hydraulic Model (SWMM5)
by Helene Schmelzing and Britta Schmalz
Hydrology 2025, 12(8), 200; https://doi.org/10.3390/hydrology12080200 - 31 Jul 2025
Viewed by 466
Abstract
To date, few studies have been published for cities in Germany that take into account climate change and changing hydrologic patterns due to increases in building density. This study investigates the efficiency of LID for past and future climate in the polycentric agglomeration [...] Read more.
To date, few studies have been published for cities in Germany that take into account climate change and changing hydrologic patterns due to increases in building density. This study investigates the efficiency of LID for past and future climate in the polycentric agglomeration area Frankfurt, Main (Central Germany) using observed and projected climate (model) data for a standard reference period (1961–1990) and a high emission scenario (RCP 8.5) as well as a climate protection scenario (RCP 2.6), under 40 to 75 percent building density. LID elements included green roofs, permeable pavement and bioretention cells. SWMM5 was used as model for simulation purposes. A holistic evaluation of simulation results showed that effectiveness increases incrementally with LID implementation percentage and inverse to building density if implemented onto at least 50 percent of available impervious area. Building density had a higher adverse effect on LID efficiency than climate change. The results contribute to the understanding of localized effects of climate change and the implementation of adaption strategies to that end. The results of this study can be helpful for the scientific community regarding future investigations of LID implementation efficiency in dense residential areas and used by local governments to provide suggestions for urban water balance revaluation. Full article
(This article belongs to the Topic Water Management in the Age of Climate Change)
Show Figures

Figure 1

39 pages, 9517 KiB  
Article
Multidimensional Evaluation Framework and Classification Strategy for Low-Carbon Technologies in Office Buildings
by Hongjiang Liu, Yuan Song, Yawei Du, Tao Feng and Zhihou Yang
Buildings 2025, 15(15), 2689; https://doi.org/10.3390/buildings15152689 - 30 Jul 2025
Viewed by 264
Abstract
The global climate crisis has driven unprecedented agreements among nations on carbon mitigation. With China’s commitment to carbon peaking and carbon neutrality targets, the building sector has emerged as a critical focus for emission reduction, particularly because office buildings account for over 30% [...] Read more.
The global climate crisis has driven unprecedented agreements among nations on carbon mitigation. With China’s commitment to carbon peaking and carbon neutrality targets, the building sector has emerged as a critical focus for emission reduction, particularly because office buildings account for over 30% of building energy consumption. However, a systematic and regionally adaptive low-carbon technology evaluation framework is lacking. To address this gap, this study develops a multidimensional decision-making system to quantify and rank low-carbon technologies for office buildings in Beijing. The method includes four core components: (1) establishing three archetypal models—low-rise (H ≤ 24 m), mid-rise (24 m < H ≤ 50 m), and high-rise (50 m < H ≤ 100 m) office buildings—based on 99 office buildings in Beijing; (2) classifying 19 key technologies into three clusters—Envelope Structure Optimization, Equipment Efficiency Enhancement, and Renewable Energy Utilization—using bibliometric analysis and policy norm screening; (3) developing a four-dimensional evaluation framework encompassing Carbon Reduction Degree (CRD), Economic Viability Degree (EVD), Technical Applicability Degree (TAD), and Carbon Intensity Degree (CID); and (4) conducting a comprehensive quantitative evaluation using the AHP-entropy-TOPSIS algorithm. The results indicate distinct priority patterns across the building types: low-rise buildings prioritize roof-mounted photovoltaic (PV) systems, LED lighting, and thermal-break aluminum frames with low-E double-glazed laminated glass. Mid- and high-rise buildings emphasize integrated PV-LED-T8 lighting solutions and optimized building envelope structures. Ranking analysis further highlights LED lighting, T8 high-efficiency fluorescent lamps, and rooftop PV systems as the top-recommended technologies for Beijing. Additionally, four policy recommendations are proposed to facilitate the large-scale implementation of the program. This study presents a holistic technical integration strategy that simultaneously enhances the technological performance, economic viability, and carbon reduction outcomes of architectural design and renovation. It also establishes a replicable decision-support framework for decarbonizing office and public buildings in cities, thereby supporting China’s “dual carbon” goals and contributing to global carbon mitigation efforts in the building sector. Full article
Show Figures

Figure 1

16 pages, 2460 KiB  
Article
Continuous Chamber Gangue Storage for Sustainable Mining in Coal Mines: Principles, Methods, and Environmental Benefits
by Jinhai Liu, Yuanhang Wang, Jiajie Li, Desire Ntokoma, Zhengxing Yu, Sitao Zhu and Michael Hitch
Sustainability 2025, 17(15), 6865; https://doi.org/10.3390/su17156865 - 28 Jul 2025
Viewed by 322
Abstract
Coal gangue, a major by-product of coal mining, poses significant environmental challenges due to its large-scale accumulation, land occupation, and potential for air and water pollution. This manuscript presents a comprehensive overview of continuous chamber gangue storage technology as a sustainable mining solution [...] Read more.
Coal gangue, a major by-product of coal mining, poses significant environmental challenges due to its large-scale accumulation, land occupation, and potential for air and water pollution. This manuscript presents a comprehensive overview of continuous chamber gangue storage technology as a sustainable mining solution for coal mines. The principles of this approach emphasize minimizing disturbance to overlying strata, enabling uninterrupted mining operations, and reducing both production costs and environmental risks. By storing the surface or underground gangue in continuous chambers, the proposed method ensures the roof stability, maximizes the waste storage, and prevents the interaction between mining and waste management processes. Detailed storage sequences and excavation methods are discussed, including continuous and jump-back excavation strategies tailored to varying roof conditions. The process flows for both underground and ground-based chamber storage are described, highlighting the integration of gangue crushing, paste preparation, and pipeline transport for efficient underground storage. In a case study with annual storage of 500,000 t gangue, the annual economic benefit reached CNY 1,111,425,000. This technology not only addresses the urgent need for sustainable coal gangue management, but also aligns with the goals of resource conservation, ecological protection, and the advancement of green mining practices in the coal industry. Full article
Show Figures

Figure 1

27 pages, 47905 KiB  
Article
FDS-Based Study on Fire Spread and Control in Modern Brick-Timber Architectural Heritage: A Case Study of Faculty House at a University in Changsha
by Simian Liu, Gaocheng Liang, Lei Shi, Ming Luo and Meizhen Long
Sustainability 2025, 17(15), 6773; https://doi.org/10.3390/su17156773 - 25 Jul 2025
Viewed by 474
Abstract
The modern Chinese architectural heritage combines sturdy Western materials with delicate Chinese styling, mainly adopting brick-timber structural systems that are highly vulnerable to fire damage. The study assesses the fire spread characteristics of the First Faculty House, a 20th-century architectural heritage located at [...] Read more.
The modern Chinese architectural heritage combines sturdy Western materials with delicate Chinese styling, mainly adopting brick-timber structural systems that are highly vulnerable to fire damage. The study assesses the fire spread characteristics of the First Faculty House, a 20th-century architectural heritage located at a university in China. The assessment is carried out by analyzing building materials, structural configuration, and fire load. By using FDS (Fire Dynamics Simulator (PyroSim version 2022)) and SketchUp software (version 2023) for architectural reconstruction and fire spread simulation, explores preventive measures to reduce fire risks. The result show that the total fire load of the building amounts to 1,976,246 MJ. After ignition, flashover occurs at 700 s, accompanied by a sharp increase in the heat release rate (HRR). The peak ceiling temperature reaches 750 °C. The roof trusses have critical structural weaknesses when approaching flashover conditions, indicating a high potential for collapse. Three targeted fire protection strategies are proposed in line with the heritage conservation principle of minimal visual and functional intervention: fire sprinkler systems, fire retardant coating, and fire barrier. Simulations of different strategies demonstrate their effectiveness in mitigating fire spread in elongated architectural heritages with enclosed ceiling-level ignition points. The efficacy hierarchy follows: fire sprinkler system > fire retardant coating > fire barrier. Additionally, because of chimney effect, for fire sources located above the ceiling and other hidden locations need to be warned in a timely manner to prevent the thermal plume from invading other sides of the ceiling through the access hole. This research can serve as a reference framework for other Modern Chinese Architectural Heritage to develop appropriate fire mitigation strategies and to provide a methodology for sustainable development of the Chinese architectural heritage. Full article
Show Figures

Figure 1

22 pages, 37656 KiB  
Article
Investigating Urban Heat Islands in Miami, Florida, Utilizing Planet and Landsat Satellite Data
by Suraj K C, Anuj Chiluwal, Lalit Pun Magar and Kabita Paudel
Atmosphere 2025, 16(7), 880; https://doi.org/10.3390/atmos16070880 - 18 Jul 2025
Viewed by 599
Abstract
Miami, Florida, renowned for its cultural richness and coastal beauty, also faces the concerning challenges created by urban heat islands (UHIs). As one of the hottest cities of the United States, Miami is facing escalating temperatures and threatening heat-related vulnerabilities due to urbanization [...] Read more.
Miami, Florida, renowned for its cultural richness and coastal beauty, also faces the concerning challenges created by urban heat islands (UHIs). As one of the hottest cities of the United States, Miami is facing escalating temperatures and threatening heat-related vulnerabilities due to urbanization and climate change. Our study addresses the critical issue of mapping and investigating UHIs in complex urban settings. This study leveraged Planet satellite data and Landsat data to conceptualize and develop appropriate mitigation strategies for UHIs in Miami. Utilizing the Planet satellite imagery and Landsat data, we conducted a combined study of land cover and land surface temperature variations within the city. This approach fuses remotely sensed data to identify the UHI hotspots. This study aims for dynamic approaches for UHI mitigation. This includes studying the status of green spaces present in the city, possible expansion of urban green spaces, the propagation of cool roof initiatives, and exploring the recent climatic trend of the city. The research revealed that built-up areas consistently showed higher land surface temperatures while zones with dense vegetation have lower surface temperatures, supporting the role of urban green spaces in surface temperature reduction. This research can also set a robust model for addressing UHIs in other cities facing rapid urbanization and experiencing mounting temperatures each passing year by helping in assessing LST, land cover, and related spectral indices as well. Full article
(This article belongs to the Section Atmospheric Techniques, Instruments, and Modeling)
Show Figures

Figure 1

23 pages, 20067 KiB  
Article
On-Site Construction and Experimental Study of Prefabricated High-Strength Thin Concrete Segment Liners for the Reinforcement of Underground Box Culverts
by Shi-Qing Wang, Yanpo Bai, Hongwen Gu, Ning Zhao and Xu-Yang Cao
Buildings 2025, 15(14), 2509; https://doi.org/10.3390/buildings15142509 - 17 Jul 2025
Viewed by 316
Abstract
Conventional trenchless pipeline rehabilitation technologies are primarily designed for circular pipelines, with limited applicability to box culvert structures. Even when adapted, these methods often lead to significant reductions in the effective cross-sectional area and fail to enhance the structural load-bearing capacity due to [...] Read more.
Conventional trenchless pipeline rehabilitation technologies are primarily designed for circular pipelines, with limited applicability to box culvert structures. Even when adapted, these methods often lead to significant reductions in the effective cross-sectional area and fail to enhance the structural load-bearing capacity due to geometric incompatibilities. To overcome these limitations, this study proposes a novel construction approach that employs prefabricated high-strength thin concrete segment liners for the reinforcement of underground box culverts. The feasibility of this method was validated through full-scale (1:1) experimental construction in a purpose-built test culvert, demonstrating rapid and efficient installation. A static stacking load test was subsequently conducted on the reinforced upper section of the culvert. Results indicate that the proposed reinforcement method effectively restores structural integrity and satisfies load-bearing and serviceability requirements, even after removal of the original roof slab. Additionally, a finite element analysis was performed to simulate the stacking load test conditions. The simulation revealed that variations in the mechanical properties of the grout between the existing structure and the new lining had minimal impact on the internal force distribution and deformation behavior of the prefabricated segments. The top segment consistently exhibited semi-rigid fixation behavior. This study offers a promising strategy for the rehabilitation of urban underground box culverts, achieving structural performance recovery while minimizing traffic disruption and enhancing construction efficiency. Full article
(This article belongs to the Topic Resilient Civil Infrastructure, 2nd Edition)
Show Figures

Figure 1

25 pages, 7566 KiB  
Article
Optimization and Benefit Assessment of LID Layout Based on the MCDA Approach at a Campus Scale
by Zexin Lei, Lijun Li, Yanrou Wei, Wenzheng Zhang, Junjie Luo and Xuqiang Zhao
Land 2025, 14(7), 1434; https://doi.org/10.3390/land14071434 - 8 Jul 2025
Viewed by 472
Abstract
Low-impact development (LID) offers environmental, economic, and social benefits, yet research on optimizing facility combinations remains limited. This study evaluates four representative LID types—green roofs, sunken green spaces, permeable pavement, and rain gardens—using an integrated framework combining the Storm Water Management Model (SWMM), [...] Read more.
Low-impact development (LID) offers environmental, economic, and social benefits, yet research on optimizing facility combinations remains limited. This study evaluates four representative LID types—green roofs, sunken green spaces, permeable pavement, and rain gardens—using an integrated framework combining the Storm Water Management Model (SWMM), NSGA-II genetic algorithm, and Analytic Hierarchy Process (AHP) at Taiyuan University of Technology in Shanxi Province, China. Based on site constraints, each LID type was pre-assigned to suitable subareas, and optimization focused on determining proportional allocations within these areas. SWMM simulations revealed that permeable paving achieved the highest runoff reduction (up to 19.4% at 65% coverage) and strong cost-effectiveness (0.013 USD per % reduction). NSGA-II was used to generate a set of optimal solutions by minimizing construction costs and maximizing runoff and pollutant reductions. AHP then ranked these solutions according to their environmental, economic, and social benefits. In this case, the ideal mix—subject to site-specific constraints and model assumptions—includes 28.58% green roofs, 19.37% sunken green spaces, 48.68% permeable paving, and 3.37% rain gardens. The study proposes a sponge campus renewal strategy, offering theoretical and practical insights for sustainable urban development and precise environmental management. Full article
(This article belongs to the Section Land Planning and Landscape Architecture)
Show Figures

Figure 1

21 pages, 17359 KiB  
Article
Multi-Objective Optimization of Urban Residential Envelope Structures in Cold Regions of China Based on Performance and Economic Efficiency
by Kezheng Deng, Yanqiu Cui, Qingtan Deng, Ruixia Liu, Zhengshu Chen and Siyu Wang
Buildings 2025, 15(13), 2365; https://doi.org/10.3390/buildings15132365 - 5 Jul 2025
Viewed by 284
Abstract
China’s urban residential building stock is extensive and spans a wide range of construction periods. With the continuous enhancement of building energy efficiency standards, the chronological characteristics and variability of residential building envelopes are evident. Through field research and typological analysis of residential [...] Read more.
China’s urban residential building stock is extensive and spans a wide range of construction periods. With the continuous enhancement of building energy efficiency standards, the chronological characteristics and variability of residential building envelopes are evident. Through field research and typological analysis of residential buildings in Jinan, a cold region of China, three construction eras were classified: Period I (1980–1985), Period II (1986–1995), and Period III (1996–2005). Building performance and economic benefits across these periods are modeled using Rhino 7.3 and Grasshopper. The NSGA-II algorithm, as the core of Wallacei2.7, is employed for multi-objective optimization. Through K-means clustering, TOPSIS comprehensive ranking, and Pearson correlation analysis, the optimized processes and solutions are provided for urban residential renovation decisions in different periods and target preferences. The results show that the optimal comprehensive performance solutions for Period I, Period II, and Period III achieve energy savings of 40.92%, 29.62%, and 15.81%, respectively, and increase annual indoor comfort hours by 872.64 h/year, 633.57 h/year, and 564.11 h/year. For Period I and II residential buildings, the most effective energy efficiency retrofit measures include increasing exterior wall and roof insulation, replacing exterior window types, and reducing exterior window k-value. The overall trend in energy savings rates and economic benefits across the three periods shows a decline. For Period III residential buildings, systematic strategies, such as solar thermal collector systems and photovoltaic technology, are required to enhance energy efficiency. Full article
(This article belongs to the Topic Building Energy and Environment, 2nd Edition)
Show Figures

Figure 1

26 pages, 918 KiB  
Review
The Role of Urban Green Spaces in Mitigating the Urban Heat Island Effect: A Systematic Review from the Perspective of Types and Mechanisms
by Haoqiu Lin and Xun Li
Sustainability 2025, 17(13), 6132; https://doi.org/10.3390/su17136132 - 4 Jul 2025
Viewed by 1482
Abstract
Due to rising temperatures, energy use, and thermal discomfort, urban heat islands (UHIs) pose a serious environmental threat to urban sustainability. This systematic review synthesizes peer-reviewed literature on various forms of green infrastructure and their mechanisms for mitigating UHI effects, and the function [...] Read more.
Due to rising temperatures, energy use, and thermal discomfort, urban heat islands (UHIs) pose a serious environmental threat to urban sustainability. This systematic review synthesizes peer-reviewed literature on various forms of green infrastructure and their mechanisms for mitigating UHI effects, and the function of urban green spaces (UGSs) in reducing the impact of UHI. In connection with urban parks, green roofs, street trees, vertical greenery systems, and community gardens, important mechanisms, including shade, evapotranspiration, albedo change, and ventilation, are investigated. This study emphasizes how well these strategies work to lower city temperatures, enhance air quality, and encourage thermal comfort. For instance, the findings show that green areas, including parks, green roofs, and street trees, can lower air and surface temperatures by as much as 5 °C. However, the efficiency of cooling varies depending on plant density and spatial distribution. While green roofs and vertical greenery systems offer localized cooling in high-density urban settings, urban forests and green corridors offer thermal benefits on a larger scale. To maximize their cooling capacity and improve urban resilience to climate change, the assessment emphasizes the necessity of integrating UGS solutions into urban planning. To improve the implementation and efficacy of green spaces, future research should concentrate on policy frameworks and cutting-edge technology such as remote sensing. Full article
Show Figures

Figure 1

26 pages, 9909 KiB  
Article
Three-Tiered Defensive System and Ethnic Fusion: A Study of Architectural Art in Guomari Fortress, Eastern Qinghai
by Liyue Wu, Qinchuan Zhan and Yanjun Li
Buildings 2025, 15(13), 2218; https://doi.org/10.3390/buildings15132218 - 24 Jun 2025
Cited by 1 | Viewed by 531
Abstract
Guomari fortress in eastern Qinghai Province exemplifies vernacular architecture shaped by multiethnic interaction, environmental adaptation, and localized defense strategies. Originally a Ming Dynasty military-agricultural outpost, it evolved into a Tu ethnic settlement. Fieldwork, including architectural surveys and spatial analysis, identified a three-tiered defensive [...] Read more.
Guomari fortress in eastern Qinghai Province exemplifies vernacular architecture shaped by multiethnic interaction, environmental adaptation, and localized defense strategies. Originally a Ming Dynasty military-agricultural outpost, it evolved into a Tu ethnic settlement. Fieldwork, including architectural surveys and spatial analysis, identified a three-tiered defensive system: (1) strategic use of terrain and rammed-earth walls; (2) labyrinthine alleys with L-, T-, and cross-shaped intersections; and (3) interconnected rooftops forming elevated circulation routes. Courtyards are categorized into single-line, L-shaped, U-shaped, and fully enclosed layouts, reflecting adaptations to terrain, ritual functions, and thermal needs. Architectural features such as thick loam-coated walls and flat roofs demonstrate climatic adaptation, while the integration of Han timber frameworks, Tibetan prayer halls, and Tu decorative elements reveals cultural convergence. Traditional craftsmanship, including carved wooden scripture blocks and tsampa-based murals, is embedded within domestic and ritual spaces. The fortress’s circulation patterns mirror Tibetan Buddhist cosmology, with mandala-like alleys and rooftop circumambulation routes. These findings offer insights into vernacular resilience and inform conservation strategies for multiethnic fortified settlements. Full article
(This article belongs to the Section Building Materials, and Repair & Renovation)
Show Figures

Figure 1

20 pages, 1669 KiB  
Article
Assessing the Energy and Economic Performance of Green and Cool Roofs: A Life Cycle Approach
by Taylana Piccinini Scolaro and Enedir Ghisi
Sustainability 2025, 17(13), 5782; https://doi.org/10.3390/su17135782 - 23 Jun 2025
Viewed by 411
Abstract
Green and cool roofs have significant potential to reduce energy consumption in buildings, but high initial costs and the need for local adaptation limit their adoption. This study aims to compare the life cycle energy assessment (LCEA) and life cycle cost analysis (LCCA) [...] Read more.
Green and cool roofs have significant potential to reduce energy consumption in buildings, but high initial costs and the need for local adaptation limit their adoption. This study aims to compare the life cycle energy assessment (LCEA) and life cycle cost analysis (LCCA) of green, cool, and standard (fibre cement) roofs in three Brazilian cities with different climatic and economic contexts. Computer simulations were carried out on a multifamily residential building model to assess the energy performance of the roofs. The simulation results and literature data were used to estimate the roofs’ energy consumption and cost over the life cycle. Over a 40-year life cycle, green and cool roofs reduced energy consumption by 13% to 22% compared to standard roofs. Cool roofs showed the lowest life cycle costs, while green roofs faced cost-effectiveness challenges due to high initial and maintenance costs. However, in areas with high energy demands and electricity tariffs, the life cycle cost of green roofs may be decreased. The study highlights the crucial role of material selection in embodied energy and emphasises the dominant impact of the operational phase on energy consumption and life cycle costs. These findings underscore the need for customised design strategies and localised assessments to support decision-making. Full article
(This article belongs to the Special Issue Green Construction Materials and Sustainability)
Show Figures

Figure 1

Back to TopTop