Sign in to use this feature.

Years

Between: -

Subjects

remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline

Journals

Article Types

Countries / Regions

Search Results (109)

Search Parameters:
Keywords = quartz tuning fork

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
16 pages, 2021 KB  
Article
PPB-Level Detection of Dissolved Acetylene in Transformer Oil Based on a Clamp-Type Quartz-Enhanced Photoacoustic Spectroscopy System
by Yihua Qian, Yaohong Zhao, Qing Wang, Kun Jia, Guobin Zhong and Huadan Zheng
Photonics 2026, 13(6), 545; https://doi.org/10.3390/photonics13060545 - 1 Jun 2026
Viewed by 273
Abstract
Dissolved gas analysis (DGA) is an essential technique for the fault diagnosis and condition monitoring of oil-immersed power transformers. Among various characteristic gases, acetylene (C2H2) is a key indicator of high-energy discharge and arc faults. In this work, a [...] Read more.
Dissolved gas analysis (DGA) is an essential technique for the fault diagnosis and condition monitoring of oil-immersed power transformers. Among various characteristic gases, acetylene (C2H2) is a key indicator of high-energy discharge and arc faults. In this work, a high-sensitivity dissolved acetylene detection system is developed based on clamp-type quartz-enhanced photoacoustic spectroscopy (QEPAS). A specially designed clamp-type quartz tuning fork (Clamp-type QTF) is employed as the acoustic transducer to improve acoustic coupling efficiency and optical alignment tolerance. Compared with conventional standard quartz tuning forks, the clamp-type structure exhibits enlarged acoustic interaction volume, lower damping loss, and higher signal collection capability. A near-infrared distributed feedback (DFB) laser operating at 1531.6 nm is used as the excitation source. The dissolved gas is extracted from transformer oil using a headspace degassing module and introduced into the QEPAS cell for real-time measurement. Experimental results showed that the developed system achieves a 1σ-based SNR-estimated detection limit of 17 ppb at a 50 s integration time, derived from the continuous measurement of 0.75 ppm C2H2, with excellent linearity in the concentration range from 100 ppm to 500 ppm. The measured concentration of dissolved acetylene in transformer oil is in good agreement with gas chromatography (GC), validating the effectiveness and practical applicability of the proposed system. Full article
(This article belongs to the Special Issue New Trends in Optical Sensing Techniques)
Show Figures

Figure 1

14 pages, 3758 KB  
Article
1D U-Net Enhanced QEPAS Sensor for Trace Water Vapor Detection
by Huiming Xiao, Jiahui Wu, Haoyang Lin, Lihao Wang, Jianfeng He, Leqing Lin, Ruobin Zhuang, Guantian Hong, Jiabao Xie, Jianhui Yu, Wenguo Zhu, Yongchun Zhong, Zhigang Song and Huadan Zheng
Optics 2026, 7(1), 15; https://doi.org/10.3390/opt7010015 - 9 Feb 2026
Cited by 1 | Viewed by 989
Abstract
We report a deep learning-assisted quartz-enhanced photoacoustic spectroscopy (QEPAS) sensor for trace water vapor detection in air. A 1392 nm butterfly-packaged DFB laser is wavelength-modulated at f0/2, and the QEPAS signal is retrieved by second-harmonic (2f) lock-in demodulation using [...] Read more.
We report a deep learning-assisted quartz-enhanced photoacoustic spectroscopy (QEPAS) sensor for trace water vapor detection in air. A 1392 nm butterfly-packaged DFB laser is wavelength-modulated at f0/2, and the QEPAS signal is retrieved by second-harmonic (2f) lock-in demodulation using a commercial quartz tuning fork gas cell. After optimizing the modulation depth to 400 mV, a 1D U-Net denoising network trained with pseudo-clean supervision is applied to the measured 2f traces, yielding an SNR improvement of 2.05× (3.11 dB). Allan deviation analysis indicates a minimum detection limit (MDL) of ~2.21 ppm at an optimum averaging time of ~619 s, corresponding to an ~2.1× improvement compared with the raw output. These results demonstrate that neural-network-based post-processing can improve QEPAS water vapor sensing performance without modifying the optical hardware. Full article
(This article belongs to the Section Laser Sciences and Technology)
Show Figures

Figure 1

15 pages, 3905 KB  
Article
Integrated Methane Sensor Prototype Based on H-QEPAS Technique with a 3D-Printed Gas Chamber
by Jingze Cai, Yanjun Chen, Hanxu Ma, Shunda Qiao, Ying He, Qi Li, Tongyu Dai and Yufei Ma
Appl. Sci. 2026, 16(3), 1427; https://doi.org/10.3390/app16031427 - 30 Jan 2026
Viewed by 591
Abstract
In the paper, a heterodyne quartz-enhanced photoacoustic spectroscopy (H-QEPAS)-based integrated methane (CH4) sensor prototype is reported. The CH4 absorption line located at 1650.96 nm was selected as the target spectral line. The design features an integrated, 3D-printed gas chamber for [...] Read more.
In the paper, a heterodyne quartz-enhanced photoacoustic spectroscopy (H-QEPAS)-based integrated methane (CH4) sensor prototype is reported. The CH4 absorption line located at 1650.96 nm was selected as the target spectral line. The design features an integrated, 3D-printed gas chamber for reduced size and weight. To realize the coordinated operation of each hardware component, a control program was designed based on LabVIEW platform, enabling the adjustment of various hardware parameters. The piezoelectric signal generated by the quartz tuning fork (QTF) was amplified via a trans-impedance amplifier (TIA), acquired by a data acquisition card (DAQ), and then transmitted to a virtual lock-in amplifier (LIA) on the PC terminal for processing. The dimensions of the integrated CH4 sensor prototype are 33 cm in length, 27 cm in width, and 15 cm in height. The final test results demonstrate that the sensor prototype exhibits an excellent concentration linear response, with a detection limit of 26.72 ppm and a short detection time of approximately 4 s. Full article
(This article belongs to the Special Issue Latest Applications of Laser Measurement Technologies)
Show Figures

Figure 1

13 pages, 1863 KB  
Article
A Compact 2.3 μm DFB-Laser CO Sensor Using MPC-LITES for Real-Time Monitoring of Cigarette Smoke
by Leqing Lin, Haoyang Lin, Guantian Hong, Jianfeng He, Lihao Wang, Ruobin Zhuang, Wenguo Zhu, Yongchun Zhong, Jianhui Yu and Huadan Zheng
Sensors 2025, 25(22), 6894; https://doi.org/10.3390/s25226894 - 12 Nov 2025
Cited by 2 | Viewed by 1049
Abstract
A compact and high-sensitivity carbon monoxide (CO) detection system based on multi-pass cell enhanced light-induced thermoelastic spectroscopy (MPC-LITES) was developed for real-time monitoring. A 2.3 μm distributed feedback (DFB) diode laser targeting the CO absorption line at 4300.699 cm−1 was employed, offering [...] Read more.
A compact and high-sensitivity carbon monoxide (CO) detection system based on multi-pass cell enhanced light-induced thermoelastic spectroscopy (MPC-LITES) was developed for real-time monitoring. A 2.3 μm distributed feedback (DFB) diode laser targeting the CO absorption line at 4300.699 cm−1 was employed, offering strong line intensity and minimal interference from H2O, CO2, NO2, and SO2. The optimal modulation depth of 0.76 cm−1 produced the maximum second harmonic (2f) signal. Experimental results demonstrated excellent linearity (R2 = 0.998) and a minimum detection limit of 230 ppb at 1 s, further reduced to 47 ppb at 367 s by Allan deviation analysis. Application tests were carried out for real-time monitoring of cigarette smoke in a 20 m2 indoor environment. Under closed conditions, the CO concentration rapidly increased to approximately 165 ppm, while in ventilated conditions, it peaked at 45 ppm and decayed quickly due to air exchange. The results confirm that the proposed MPC-LITES sensor enables accurate, real-time detection of transient CO variations, demonstrating strong potential for indoor air quality evaluation, environmental safety, and public health protection. Full article
Show Figures

Figure 1

22 pages, 5264 KB  
Article
Development of Compact Electronics for QEPAS Sensors
by Vincenzina Zecchino, Luigi Lombardi, Cristoforo Marzocca, Pietro Patimisco, Angelo Sampaolo and Vincenzo Luigi Spagnolo
Sensors 2025, 25(21), 6718; https://doi.org/10.3390/s25216718 - 3 Nov 2025
Cited by 3 | Viewed by 1082
Abstract
Remarkable advances in Quartz-Enhanced Photoacoustic Spectroscopy (QEPAS) made it one of the most effective gas-sensing techniques in terms of sensitivity and selectivity. Consequently, its range of possible applications is continuously expanding, but in some cases is still limited by the cost and/or size [...] Read more.
Remarkable advances in Quartz-Enhanced Photoacoustic Spectroscopy (QEPAS) made it one of the most effective gas-sensing techniques in terms of sensitivity and selectivity. Consequently, its range of possible applications is continuously expanding, but in some cases is still limited by the cost and/or size of the equipment needed to im-plement a complete QEPAS sensor. In particular, bulky and expensive lab instruments are often used to realize the electronic building blocks required by this technique, which prevents, for instance, integration of the system on board a drone. This work addresses this issue by presenting the development of compact electronic modules for a QEPAS sensor. A very low-noise, fully differential preamplifier for the quartz tuning fork, with digital output and programmable gain, has been designed and realized. A compact FPGA board hosts both an accurate function generation module, which synthesizes the signals needed to modulate the laser source, and an innovative lock-in amplifier based on the CORDIC algorithm. QEPAS sensors based on the designed electronics have been used for the detection of H2O and CO2 in ambient air, proving the full functionality of all the blocks. These results highlight the potential of compact electronics to promote portable and cost-effective QEPAS applications. Full article
(This article belongs to the Special Issue Laser Spectroscopy Sensing for Gas Detection)
Show Figures

Figure 1

12 pages, 3116 KB  
Article
Dual-Component Beat-Frequency Quartz-Enhanced Photoacoustic Spectroscopy Gas Detection System
by Hangyu Xu, Yiwen Feng, Zihao Chen, Zhenzhao Zhuang, Jinbao Xia, Yiyang Zhao and Sasa Zhang
Photonics 2025, 12(8), 747; https://doi.org/10.3390/photonics12080747 - 24 Jul 2025
Cited by 3 | Viewed by 2002
Abstract
This study designed and validated a dual-component beat-frequency quartz-enhanced photoacoustic spectroscopy (BF-QEPAS) gas detection system utilizing time-division multiplexing (TDM). By applying TDM to drive distributed feedback lasers, the system achieved the simultaneous detection of acetylene and methane. Its key innovation lies in exploiting [...] Read more.
This study designed and validated a dual-component beat-frequency quartz-enhanced photoacoustic spectroscopy (BF-QEPAS) gas detection system utilizing time-division multiplexing (TDM). By applying TDM to drive distributed feedback lasers, the system achieved the simultaneous detection of acetylene and methane. Its key innovation lies in exploiting the transient response of the quartz tuning fork (QTF) to acquire gas concentrations while concurrently capturing the QTF resonant frequency and quality factor in real-time. Owing to the short beat period and rapid system response, this approach significantly reduces time-delay constraints in time-division measurements, eliminating the need for periodic calibration inherent in conventional methods and preventing detection interruptions. The experimental results demonstrate minimum detection limits of 5.69 ppm for methane and 0.60 ppm for acetylene. Both gases exhibited excellent linear responses over the concentration range of 200 ppm to 4000 ppm, with the R2 value for methane being 0.996 and for acetylene being 0.997. The system presents a viable solution for the real-time, calibration-free monitoring of dissolved gases in transformer oil. Full article
(This article belongs to the Special Issue Advances in Optical Fiber Sensing Technology)
Show Figures

Figure 1

10 pages, 1296 KB  
Article
High-Sensitivity Dynamic Detection of Dissolved Acetylene in Transformer Oil Based on High-Power Quartz-Enhanced Photoacoustic Spectroscopy Sensing System
by Yuxiang Wu, Tiehua Ma, Chenhua Liu, Yashan Fan, Shuai Shi, Songjie Guo, Yu Wang, Xiangjun Xu, Guqing Guo, Xuanbing Qiu, Zhijin Shang and Chuanliang Li
Photonics 2025, 12(7), 713; https://doi.org/10.3390/photonics12070713 - 16 Jul 2025
Cited by 5 | Viewed by 1497
Abstract
To enable the highly sensitive detection of acetylene (C2H2) dissolved in transformer oil, a high-power quartz-enhanced photoacoustic spectroscopy (QEPAS) sensing system is proposed. A standard 32.7 kHz quartz tuning fork (QTF) was employed as an acoustic transducer, coupled with [...] Read more.
To enable the highly sensitive detection of acetylene (C2H2) dissolved in transformer oil, a high-power quartz-enhanced photoacoustic spectroscopy (QEPAS) sensing system is proposed. A standard 32.7 kHz quartz tuning fork (QTF) was employed as an acoustic transducer, coupled with an optimized acoustic resonator to enhance the acoustic signal. The laser power was boosted to 150 mW using a C-band erbium-doped fiber amplifier (EDFA), achieving a detection limit of 469 ppb for C2H2 with an integration time of 1 s. The headspace degassing method was utilized to extract dissolved gases from the transformer oil, and the equilibrium process for the release of dissolved C2H2 was successfully monitored using the developed high-power QEPAS system. This approach provides reliable technical support for the real-time monitoring of the operational safety of power transformers. Full article
(This article belongs to the Section Lasers, Light Sources and Sensors)
Show Figures

Figure 1

16 pages, 8177 KB  
Article
Study and Characterization of Silicon Nitride Optical Waveguide Coupling with a Quartz Tuning Fork for the Development of Integrated Sensing Platforms
by Luigi Melchiorre, Ajmal Thottoli, Artem S. Vorobev, Giansergio Menduni, Angelo Sampaolo, Giovanni Magno, Liam O’Faolain and Vincenzo Spagnolo
Sensors 2025, 25(12), 3663; https://doi.org/10.3390/s25123663 - 11 Jun 2025
Cited by 6 | Viewed by 3281
Abstract
This work demonstrates an ultra-compact optical gas-sensing system, consisting of a pigtailed laser diode emitting at 1392.5 nm for water vapor (H2O) detection, a silicon nitride (Si3N4) optical waveguide to guide the laser light, and a custom-designed, [...] Read more.
This work demonstrates an ultra-compact optical gas-sensing system, consisting of a pigtailed laser diode emitting at 1392.5 nm for water vapor (H2O) detection, a silicon nitride (Si3N4) optical waveguide to guide the laser light, and a custom-designed, low-frequency, and T-shaped Quartz Tuning Fork (QTF) as the sensitive element. The system employs both Quartz-Enhanced Photoacoustic Spectroscopy (QEPAS) and Light-Induced Thermoelastic Spectroscopy (LITES) techniques for trace gas sensing. A 3.8 mm-wide, S-shaped waveguide path was designed to prevent scattered laser light from directly illuminating the QTF. Both QEPAS and LITES demonstrated comparably low signal-to-noise ratios (SNRs), ranging from 1.6 to 3.2 for a 1.6% indoor H2O concentration, primarily owing to the reduced optical power (~300 μW) delivered to the QTF excitation point. These results demonstrate the feasibility of integrating photonic devices and piezoelectric components into portable gas-sensing systems for challenging environments. Full article
(This article belongs to the Special Issue Feature Papers in Optical Sensors 2025)
Show Figures

Figure 1

17 pages, 5333 KB  
Article
An Adaptive Three-Dimensional Self-Masking Strategy for the Micro-Fabrication of Quartz-MEMS with Out-of-Plane Vibration Units
by Yide Dong, Chunyan Yin, Guangbin Dou and Litao Sun
Micromachines 2025, 16(6), 609; https://doi.org/10.3390/mi16060609 - 23 May 2025
Cited by 1 | Viewed by 3126
Abstract
Quartz crystal out-of-plane vibration units are critical components of QMEMS devices. However, the fabrication of their 3D sidewall electrode structures presents significant challenges, particularly within ultrafine etched grooves. These challenges seriously limit further miniaturization, which is critical for portable and wearable electronic applications. [...] Read more.
Quartz crystal out-of-plane vibration units are critical components of QMEMS devices. However, the fabrication of their 3D sidewall electrode structures presents significant challenges, particularly within ultrafine etched grooves. These challenges seriously limit further miniaturization, which is critical for portable and wearable electronic applications. In this paper, we propose a novel 3D self-masking fabrication strategy that enables the precise formation of sidewall electrodes by using the etched beam structure as a self-aligned pattern transfer medium. Based solely on photolithography and wet etching processes, this approach overcomes the limitations of the conventional shadow mask technique by improving alignment accuracy, process efficiency, and fabrication yields. In addition, a predictive mathematical model was developed to guide process optimization, enabling adaptive and reliable fabrication. Sidewall electrodes were successfully achieved in etched grooves as narrow as 45 μm, closely matching the theoretical predictions. To validate the approach, an ultra-miniaturized out-of-plane vibration unit with a beam spacing of just 150 μm—the narrowest reported to date—was fabricated, representing an 80% reduction compared to previously documented structures. The unit exhibited a repeatability error below 1.13%, confirming the precision and reliability of the proposed fabrication strategy. Full article
(This article belongs to the Special Issue Two-Dimensional Materials for Electronic and Optoelectronic Devices)
Show Figures

Figure 1

12 pages, 16116 KB  
Article
All-Fiber LITES Sensor Based on Hollow-Core Anti-Resonant Fiber and Self-Designed Low-Frequency Quartz Tuning Fork
by Xiaorong Sun, Weipeng Chen, Ying He, Haiyue Sun, Shunda Qiao and Yufei Ma
Sensors 2025, 25(9), 2933; https://doi.org/10.3390/s25092933 - 6 May 2025
Cited by 2 | Viewed by 1466
Abstract
In this paper, an all-fiber light-induced thermoelastic spectroscopy (LITES) sensor based on hollow-core anti-resonant fiber (HC-ARF) and self-designed low-frequency quartz tuning fork (QTF) is reported for the first time. By utilizing HC-ARF as both the transmission medium and gas chamber, the laser tail [...] Read more.
In this paper, an all-fiber light-induced thermoelastic spectroscopy (LITES) sensor based on hollow-core anti-resonant fiber (HC-ARF) and self-designed low-frequency quartz tuning fork (QTF) is reported for the first time. By utilizing HC-ARF as both the transmission medium and gas chamber, the laser tail fiber was spatially coupled with the HC-ARF, and the end of the HC-ARF was directly guided onto the QTF surface, resulting in an all-fiber structure. This design eliminated the need for lens combinations, thereby enhancing system stability and reducing cost and size. Additionally, a self-designed rectangular-tip QTF with a low resonant frequency of 8.69 kHz was employed to improve the sensor’s detection performance. Acetylene (C2H2), with an absorption line at 6534.37 cm−1 (1.53 μm), was chosen as the target gas. Experimental results clearly demonstrated that the detection performance of the rectangular-tip QTF system was 2.9-fold higher than that of a standard commercial QTF system. Moreover, it exhibited an outstanding linear response to varying C2H2 concentrations, indicating its high sensitivity and reliability in detecting C2H2. The Allan deviation analysis was used to assess the system’s stability, and the results indicated that the system exhibits excellent long-term stability. Full article
Show Figures

Figure 1

14 pages, 5317 KB  
Article
LITES-Based Sensitive CO2 Detection Using 2 μm Diode Laser and Self-Designed 9.5 kHz Quartz Tuning Fork
by Junjie Mu, Jinfeng Hou, Shaoqi Qiu, Shunda Qiao, Ying He and Yufei Ma
Sensors 2025, 25(7), 2099; https://doi.org/10.3390/s25072099 - 27 Mar 2025
Cited by 2 | Viewed by 1240
Abstract
A carbon dioxide (CO2) sensor based on light-induced thermoelastic spectroscopy (LITES) using a 2 μm diode laser and a self-designed low-frequency trapezoidal-head QTF is reported for the first time in this invited paper. The self-designed trapezoidal-head QTF with a low resonant [...] Read more.
A carbon dioxide (CO2) sensor based on light-induced thermoelastic spectroscopy (LITES) using a 2 μm diode laser and a self-designed low-frequency trapezoidal-head QTF is reported for the first time in this invited paper. The self-designed trapezoidal-head QTF with a low resonant frequency of 9464.18 Hz and a high quality factor (Q) of 12,133.56 can significantly increase the accumulation time and signal level of the CO2-LITES sensor. A continuous-wave (CW) distributed-feedback (DFB) diode laser is used as the light source, and the strongest absorption line of CO2 located at 2004.01 nm is chosen. A comparison between the standard commercial QTF with the resonant frequency of 32.768 kHz and the self-designed trapezoidal-head QTF is performed. The experimental results show that the CO2-LITES sensor with the self-designed trapezoidal-head QTF has an excellent linear response to CO2 concentration, and its minimum detection limit (MDL) can reach 46.08 ppm (parts per million). When the average time is increased to 100 s based on the Allan variance analysis, the MDL of the sensor can be improved to 3.59 ppm. Compared with the 16.85 ppm of the CO2-LITES sensor with the commercial QTF, the performance is improved by 4.7 times, demonstrating the superiority of the self-designed trapezoidal-head QTF. Full article
(This article belongs to the Special Issue Sensors in 2025)
Show Figures

Figure 1

11 pages, 1240 KB  
Article
Calibration of a Quartz Tuning Fork as a Sound Detector
by Judith Falkhofen and Marcus Wolff
Appl. Sci. 2025, 15(7), 3655; https://doi.org/10.3390/app15073655 - 26 Mar 2025
Viewed by 1267
Abstract
This study compares the performance of a quartz tuning fork (QTF) with a highly sensitive ultrasound microphone in the context of acoustic measurements, applying the substitution calibration method. QTF sensors are increasingly used for high-precision tasks due to their sensitivity and stability, while [...] Read more.
This study compares the performance of a quartz tuning fork (QTF) with a highly sensitive ultrasound microphone in the context of acoustic measurements, applying the substitution calibration method. QTF sensors are increasingly used for high-precision tasks due to their sensitivity and stability, while microphones are still the standard in general acoustic measurements. The aim of this study is to evaluate both technologies across several key performance metrics, including linearity of response, sensitivity, noise characteristics, and acoustic detection limit. Which sensor is better suited to which acoustic and physical condition? The results show that QTFs perform exceptionally well in applications requiring high precision, especially in high-frequency and narrow-band measurements. The signal-to-noise-ratio (SNR) of the QTF at its resonance frequency is 14 dB higher than that of the microphone, whereas the detection limit and linearity are comparable. The findings suggest that QTF sensors are particularly advantageous for specialized applications like photoacoustic spectroscopy (PAS). Full article
(This article belongs to the Special Issue Application of Ultrasonic Non-destructive Testing)
Show Figures

Figure 1

10 pages, 3418 KB  
Article
Off-Beam Acoustic Micro-Resonator for QEPAS Sensor with a Custom Quartz Tuning Fork
by Yong Wang, Gang Wang, Jiapeng Wang, Chaofan Feng, Qingyuan Tian, Yifan Chen, Ruyue Cui, Hongpeng Wu and Lei Dong
Atmosphere 2025, 16(3), 352; https://doi.org/10.3390/atmos16030352 - 20 Mar 2025
Cited by 11 | Viewed by 1564
Abstract
Quartz-enhanced photoacoustic spectroscopy (QEPAS) has shown great promise for monitoring greenhouse gases and pollutants with a high measurement accuracy and limit of detection. A QEPAS sensor, which can achieve high photoacoustic signal gain without requiring the laser beam to pass through the two [...] Read more.
Quartz-enhanced photoacoustic spectroscopy (QEPAS) has shown great promise for monitoring greenhouse gases and pollutants with a high measurement accuracy and limit of detection. A QEPAS sensor, which can achieve high photoacoustic signal gain without requiring the laser beam to pass through the two prongs of a quartz tuning fork (QTF), is reported. A custom QTF with a resonant frequency of 7.2 kHz and a quality factor of 8406 was employed as a sound detection element, and the parameters of the acoustic micro-resonator (AmR) in the off-beam QEPAS spectrophone were optimized. A signal-to-noise ratio (SNR) gain of 16 was achieved based on the optimal AmR dimensions compared to the bare custom QTF. Water vapor (H2O) was detected utilizing the QEPAS sensor equipped with the off-beam spectrophone, achieving a minimum detection limit (MDL) of 4 ppm with a normalized noise equivalent absorption coefficient (NNEA) of 5.7 × 10−8 cm−1·W·Hz−1/2 at an integration time of 300 ms. Full article
(This article belongs to the Special Issue New Insights into Photoacoustic Spectroscopy and Its Applications)
Show Figures

Figure 1

13 pages, 9604 KB  
Article
A Highly Sensitive Light-Induced Thermoelastic Spectroscopy Sensor Using a Charge Amplifier to Improve the Signal-to-Noise Ratio
by Hanxu Ma, Shunda Qiao, Ying He and Yufei Ma
Sensors 2025, 25(3), 946; https://doi.org/10.3390/s25030946 - 5 Feb 2025
Cited by 3 | Viewed by 1596
Abstract
A highly sensitive light-induced thermoelastic spectroscopy (LITES) sensor employing a charge amplifier (CA) is reported for the first time in this invited paper. CA has the merits of high input impedance and strong anti-interference ability. The usually used transimpedance amplifier (TA) and voltage [...] Read more.
A highly sensitive light-induced thermoelastic spectroscopy (LITES) sensor employing a charge amplifier (CA) is reported for the first time in this invited paper. CA has the merits of high input impedance and strong anti-interference ability. The usually used transimpedance amplifier (TA) and voltage amplifier (VA) were also studied under the same conditions for comparison. A standard commercial quartz tuning fork (QTF) with a resonant frequency of approximately 32.76 kHz was used as the photothermal signal transducer. Methane (CH4) was used as the target gas in these sensors for performance verification. Compared to the TA-LITES sensor and VA-LITES sensor, the reported CA-LITES sensor shows improvements of 1.83 times and 5.28 times in the minimum detection limit (MDL), respectively. When compared to the LITES sensor without an amplifier (WA-LITES), the MDL has a 19.96-fold improvement. After further optimizing the gain of the CA, the MDL of the CA-LITES sensor was calculated as 2.42 ppm, which further improved the performance of the MDL by 30.3 times compared to the WA-LITES. Additionally, long-term stability is analyzed using Allan deviation analysis. When the average time of the sensor system is increased to 50 s, the MDL of the CA-LITES sensor system can be improved to 0.58 ppm. Full article
(This article belongs to the Section Optical Sensors)
Show Figures

Figure 1

12 pages, 10559 KB  
Article
Highly Sensitive T-Shaped Quartz Tuning Fork Based CH4-Light-Induced Thermoelastic Spectroscopy Sensor with Hydrogen and Helium Enhanced Technique
by Yuanzhi Wang, Ying He, Shunda Qiao, Xiaoming Duan and Yufei Ma
Sensors 2024, 24(23), 7743; https://doi.org/10.3390/s24237743 - 4 Dec 2024
Cited by 5 | Viewed by 2688
Abstract
In this paper, a highly sensitive methane (CH4) sensor based on light-induced thermoelastic spectroscopy (LITES) and a T-shaped quartz tuning fork (QTF) with hydrogen (H2) and helium (He) enhancement techniques are reported for the first time. The low resonant [...] Read more.
In this paper, a highly sensitive methane (CH4) sensor based on light-induced thermoelastic spectroscopy (LITES) and a T-shaped quartz tuning fork (QTF) with hydrogen (H2) and helium (He) enhancement techniques are reported for the first time. The low resonant frequency self-designed T-shaped QTF was exploited for improving the energy accumulation time. H2 and He were utilized as surrounding gases for the T-shaped QTF to minimize energy loss, thereby enhancing the sensitivity of the LITES sensor. Additionally, a fiber-coupled multi-pass cell (FC-MPC) with a 40 m optical length was utilized to improve the optical absorption of CH4. The frequency response of the T-shaped QTF with different concentrations of H2 and He was investigated, and the Q factor in the H2 and He environment increased significantly. Compared to operating QTF in a nitrogen (N2) environment, the signal amplitude was enhanced by 2.9 times and 1.9 times in pure H2 and He environments, respectively. This enhancement corresponded to a minimum detection limit (MDL) of 80.3 ppb and 113.6 ppb. Under different CH4 concentrations, the T-shaped QTF-based H2-enhanced CH4-LITES sensor showed an excellent linear response. Furthermore, through Allan deviation analysis, the MDL of the T-shaped QTF-based H2-enhanced CH4-LITES can reach 38 ppb with an 800 s integration time. Full article
(This article belongs to the Special Issue Important Achievements in Optical Measurements in China 2024–2025)
Show Figures

Figure 1

Back to TopTop