Sign in to use this feature.

Years

Between: -

Subjects

remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline

Journals

Article Types

Countries / Regions

Search Results (96)

Search Parameters:
Keywords = plastic optical fibers (POFs)

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
16 pages, 2189 KB  
Article
Biosensors Based on Plasmonic Spoon-Shaped Platforms as a Point-of-Care Tool for Escherichia coli Detection
by Francesco Arcadio, Alessandro Capo, Alessia Calabrese, Chiara Marzano, Mimimorena Seggio, Rosalba Pitruzzella, Federica Passeggio, Shahab Bashir, Muhammad Shoaib, Carla Zannella, Anna De Filippis, Giuseppe Portella, Luigi Zeni and Nunzio Cennamo
Biosensors 2026, 16(7), 371; https://doi.org/10.3390/bios16070371 - 8 Jul 2026
Viewed by 741
Abstract
The Enterobacteriaceae family is a significant source of foodborne pathogens and represents a severe threat to human and animal health. These bacteria can penetrate the dairy supply chain through direct contact with cattle and the livestock environment and can survive production processes. Escherichia [...] Read more.
The Enterobacteriaceae family is a significant source of foodborne pathogens and represents a severe threat to human and animal health. These bacteria can penetrate the dairy supply chain through direct contact with cattle and the livestock environment and can survive production processes. Escherichia coli (E. coli), one of the most diffuse bacteria in raw and processed milk, exposes consumers to the risk of contaminated milk. As a result of this exposition, several milk-borne illness outbreaks have been reported worldwide, underscoring the urgent need for effective detection and prevention measures. Conventional analysis methods are effective but have significant limitations, including the requirement of pre-treatment and pre-enrichment steps. Thus, the need for advanced detection techniques that can accurately identify these pathogens without pre-treatment steps is critical. In this work, a proof-of-concept biosensor based on a spoon-shaped optical biochip was developed to detect E. coli via surface plasmon resonance (SPR) phenomena and was combined with a polyclonal antibody layer against E. coli as a molecular recognition element (MRE). The proposed label-free biosensing strategy, achieved by exploiting simple SPR spoon-shaped biochips, exhibits a remarkable detection limit (6.8 colony-forming units, CFU/mL) and high specificity towards other interfering bacteria belonging to the Enterobacteriaceae family. In addition, tests on commercial milk samples were carried out, achieving recovery values of 95% and 102% for whole milk and infant milk, respectively. The proposed spoon-shaped biosensor enables label-free biosensing without the need for microfluidic systems. It provides a rapid response (10 min), paving the way for its use as a point-of-care test (POCT) in real-world settings. Full article
►▼ Show Figures

Figure 1

21 pages, 12789 KB  
Article
Modified Plastic Optical Fibers Combined with Molecularly Imprinted Polymers and Gold Nanorods for Furfural Detection at the Picomolar Level via Plasmonic Phenomena
by Rosalba Pitruzzella, Dalila Cicatiello, Chiara Marzano, Luca Pasquale Renzullo, Viktor Zabolotnii, Roman Viter, Luigi Zeni, Maria Pesavento, Giancarla Alberti and Nunzio Cennamo
Polymers 2026, 18(11), 1413; https://doi.org/10.3390/polym18111413 - 5 Jun 2026
Viewed by 722
Abstract
This work presents an intrinsic optical fiber sensor based on plasmonic phenomena in modified plastic optical fibers (POFs). The sensing area is achieved by replacing the polymethyl methacrylate (PMMA) core with a molecularly imprinted polymer (MIP) containing gold nanorods (GNRs). Thus, in the [...] Read more.
This work presents an intrinsic optical fiber sensor based on plasmonic phenomena in modified plastic optical fibers (POFs). The sensing area is achieved by replacing the polymethyl methacrylate (PMMA) core with a molecularly imprinted polymer (MIP) containing gold nanorods (GNRs). Thus, in the sensing area, the MIP acts as both a selective recognition element and an optically sensitive guiding medium where plasmonic phenomena occur. This optical–chemical configuration has been developed as a proof-of-concept for the detection of furfural in aqueous solution. The proposed sensor achieves a limit of detection (LOD) of 27 pM, demonstrates high selectivity for the analyte of interest, and is applicable even in real-world scenarios, as demonstrated by experimental results (a commercially available infant milk). The proposed sensor presents a significant enhancement of the sensor response, of about six orders of magnitude, compared to a conventional configuration where the same (or a similar) mixture of MIP/GNRs is spun over the exposed PMMA of a D-shaped POF area for comparison. Notably, even if this study has been carried out via a proof-of-concept in furfural detection, this substantial improvement is achieved while preserving a simple, portable, and cost-effective optical setup, highlighting the potential of this sensing strategy for the development of highly selective sensors by changing the MIP template. Full article
(This article belongs to the Special Issue Molecularly Imprinted Polymers)
►▼ Show Figures

Figure 1

18 pages, 3425 KB  
Article
Towards Haemoglobin Detection in Finger-Prick Sampling via Low-Cost Disposable Sensor Chips Based on eMIPs on Plasmonic Optical Fiber Probes
by Rosalba Pitruzzella, Dalila Cicatiello, Chiara Marzano, Federica Passeggio, Luca Gentile, José A. Ribeiro, João P. Mendes, Luís C. C. Coelho, Giuseppe Portella, Maria Chiara Capellupo, Maddalena Casale, Luigi Zeni, Pedro A. S. Jorge and Nunzio Cennamo
Nanomaterials 2026, 16(10), 602; https://doi.org/10.3390/nano16100602 - 14 May 2026
Viewed by 709
Abstract
Haemoglobin (Hb) concentration is a key biomarker for several diseases. Traditional laboratory methods often have limitations due to their time-consuming nature, the need for skilled personnel, or the use of high-cost instrumentation. This work presents a sensing strategy for developing new point-of-care tests [...] Read more.
Haemoglobin (Hb) concentration is a key biomarker for several diseases. Traditional laboratory methods often have limitations due to their time-consuming nature, the need for skilled personnel, or the use of high-cost instrumentation. This work presents a sensing strategy for developing new point-of-care tests (POCTs) for Hb detection via a proof of concept. The proposed sensing approach is implemented using plasmonic plastic optical fiber (POF) sensor chips that integrate an electropolymerized molecularly imprinted polymer (eMIP) film on the plasmonic surface for Hb-selective detection. The developed sensor system demonstrates an ultra-low detection limit of 80 fM in buffer, about five orders of magnitude lower than that of other comparable Hb sensors. Selectivity tests against common interfering proteins, such as bovine serum albumin (BSA) and immunoglobulin G (IgG), confirmed high specificity towards the target analyte. Moreover, the sensor’s performance was tested using a whole-blood sample, yielding results consistent with those of standard haematology analysis. The proposed sensor system, based on simple equipment, provides a quick (about 10 min) and cost-effective (about 10 euros per chip) label-free diagnostic tool for POCTs in real-world scenarios, such as finger-prick sampling, offering a less invasive alternative to traditional laboratory methods, towards devices useful for Internet of Medical Things (IoMT). Full article
►▼ Show Figures

Graphical abstract

18 pages, 3361 KB  
Article
Design and Analysis of a Low-Loss 1 × 2 POF Splitter Based on Planar Optical Waveguide
by Xiaohong Duan and Mohammad Syuhaimi Ab-Rahman
Photonics 2026, 13(5), 469; https://doi.org/10.3390/photonics13050469 - 9 May 2026
Cited by 1 | Viewed by 806
Abstract
To address the demand for low-cost, low-loss, and environmentally friendly optical power dividers in short-range visible light communication (VLC) systems, a low-loss 1 × 2 Y-branch optical splitter based on the integration of a planar optical waveguide (POW) and plastic optical fiber (POF) [...] Read more.
To address the demand for low-cost, low-loss, and environmentally friendly optical power dividers in short-range visible light communication (VLC) systems, a low-loss 1 × 2 Y-branch optical splitter based on the integration of a planar optical waveguide (POW) and plastic optical fiber (POF) is proposed and experimentally demonstrated. The device employs a large-core step-index POF with a core diameter of 1 mm, enabling efficient coupling of multimode optical signals. The design and structural optimization of the 1 × 2 POF splitter are simulated by the beam propagation method (BPM). We fabricated the device through a low-cost manual assembly process, followed by packaging and experimental characterization. Measurements at 650 nm on ten samples show a minimum insertion loss of 3.4 dB and a lowest excess loss of 0.8 dB. The splitting ratio ranges from 49.6%:50.4% to 37%:63%, with a minimum uniformity of 0.06, indicating stable power distribution performance. These results confirm that a simple, low-cost fabrication approach can achieve practical optical performance, offering a feasible route toward scalable polymer-based photonic integration. Full article
►▼ Show Figures

Figure 1

14 pages, 2318 KB  
Article
A Flexible Wearable Data Glove Based on Hybrid Fiber-Optic Sensing for Hand Motion Monitoring
by Jing Li, Xiangting Hou, Ke Du, Huiying Piao and Cheng Li
Materials 2026, 19(8), 1525; https://doi.org/10.3390/ma19081525 - 10 Apr 2026
Cited by 1 | Viewed by 899
Abstract
Wearable data gloves often suffer from electromagnetic interference, insufficient substrate stability, and limited capability for multi-degree-of-freedom motion measurement. To address these limitations, a flexible glove incorporating a hybrid POF-FBG sensing scheme was designed and fabricated. Plastic optical fibers (POFs) were side-polished and patterned [...] Read more.
Wearable data gloves often suffer from electromagnetic interference, insufficient substrate stability, and limited capability for multi-degree-of-freedom motion measurement. To address these limitations, a flexible glove incorporating a hybrid POF-FBG sensing scheme was designed and fabricated. Plastic optical fibers (POFs) were side-polished and patterned with long-period gratings to improve sensitivity to wrist flexion-extension and abduction-adduction. Then fiber Bragg gratings (FBGs) were embedded in a polydimethylsiloxane substrate and encapsulated using thermoplastic polyurethane fixtures to reduce the influence of skin stretching and improve measurement accuracy of finger-joint angle. Moreover, a thermoplastic polyurethane skeleton with an adaptive sliding-rail structure was 3D printed to maintain the stability of the sensor placement at the joints. Experimental results demonstrated the mean absolute errors of 4.06°, 1.38° and 1.70° for wrist flexion-extension, abduction-adduction and finger-joint bending, respectively, along with excellent gesture classification using a support vector machine algorithm, which indicates great potential in virtual reality interaction and hand rehabilitation applications. Full article
(This article belongs to the Special Issue Advances in Optical Fiber Materials and Their Applications)
►▼ Show Figures

Figure 1

14 pages, 2129 KB  
Article
A Portable D-Shaped POF-SPR Sensor Integrated with NanoMIPs for High-Affinity Detection of the SARS-CoV-2 RBD Protein
by Alice Marinangeli, Jessica Brandi, Devid Maniglio and Alessandra Maria Bossi
Appl. Sci. 2026, 16(4), 1853; https://doi.org/10.3390/app16041853 - 12 Feb 2026
Cited by 3 | Viewed by 635
Abstract
The rapid and accurate detection of SARS-CoV-2 biomarkers remains a critical requirement for effective outbreak control and decentralized diagnostics. Although RT-PCR is the current gold standard, its reliance on centralized laboratories and long processing times limits its applicability in point-of-care settings. In this [...] Read more.
The rapid and accurate detection of SARS-CoV-2 biomarkers remains a critical requirement for effective outbreak control and decentralized diagnostics. Although RT-PCR is the current gold standard, its reliance on centralized laboratories and long processing times limits its applicability in point-of-care settings. In this context, optical biosensing platforms based on surface plasmon resonance (SPR) offer attractive features, including label-free, real-time, and quantitative detection. This study explores the use of synthetic receptors for the highly sensitive detection of the receptor-binding domain (RBD) of the SARS-CoV-2 spike protein. Specifically, soft molecularly imprinted polymer nanoparticles (nanoMIPs) were employed as synthetic receptors and integrated into a high-sensitivity, portable plasmonic platform based on a D-shaped plastic optical fiber (POF) SPR sensor. The nanoMIPs were selectively imprinted against the RBD, characterized by Dynamic Light Scattering (DLS), Isothermal Titration Calorimetry (ITC), and Scanning Electron Microscopy (SEM) to confirm nanoMIPs size, binding properties, and surface morphology. Next, the nanoMIPs were immobilized onto a gold-coated sensing surface, enabling enhanced specificity, affinity, and signal amplification compared to conventional biological recognition elements. The resulting RBD-SPR-nanoMIPs sensor demonstrated promising analytical performance, exhibiting high selectivity against potentially interfering proteins and an anticipated sensitivity suitable for RBD detection at femtomolar concentrations. The inherent stability of nanoMIPs suggests the potential for reusable SPR sensing platforms, paving the way for next-generation synthetic receptor-based plasmonic biosensors. Full article
►▼ Show Figures

Figure 1

18 pages, 3675 KB  
Article
Highly Sensitive Biosensor for the Detection of Cardiac Troponin I in Serum via Surface Plasmon Resonance on Polymeric Optical Fiber Functionalized with Castor Oil-Derived Molecularly Imprinted Nanoparticles
by Alice Marinangeli, Pinar Cakir Hatir, Mustafa Baris Yagci and Alessandra Maria Bossi
Biosensors 2026, 16(1), 12; https://doi.org/10.3390/bios16010012 - 23 Dec 2025
Cited by 4 | Viewed by 2044
Abstract
In this work, we report the development of a highly sensitive optical sensor for the detection of cardiac troponin I (cTnI), a key biomarker for early-stage myocardial infarction diagnosis. The sensor combines castor oil-derived biomimetic receptors, called GreenNanoMIPs and prepared via the molecular [...] Read more.
In this work, we report the development of a highly sensitive optical sensor for the detection of cardiac troponin I (cTnI), a key biomarker for early-stage myocardial infarction diagnosis. The sensor combines castor oil-derived biomimetic receptors, called GreenNanoMIPs and prepared via the molecular imprinting technology using as a template an epitope of cTnI (i.e., the NR10 peptide), with a portable multimode plastic optical fiber surface plasmon resonance (POF-SPR) transducer. For sensing, gold SPR chips were functionalized with GreenNanoMIPs as proven by refractive index changes and confirmed by means of XPS. Binding experiments demonstrated the cTnI_nanoMIP-SPR sensor’s ability to detect both the NR10 peptide epitope and the full-length cTnI protein within minutes (t = 10 min), with high sensitivity and selectivity in buffer and serum matrices. The cTnI_nanoMIP-SPR showed an LOD of 3.53 × 10−15 M, with a linearity range of 1 pM–100 pM, outperforming previously reported sensor platforms and making it a promising tool for early-stage myocardial infarction detection. Full article
(This article belongs to the Section Optical and Photonic Biosensors)
►▼ Show Figures

Graphical abstract

17 pages, 3203 KB  
Article
Development of a Light Duct Using Relay Lenses and Diffusers
by Sowon Han, Mingoo Lee, Taegon Han, Janghoo Seo and Heangwoo Lee
Buildings 2025, 15(23), 4340; https://doi.org/10.3390/buildings15234340 - 28 Nov 2025
Viewed by 866
Abstract
Due to the recent increase in building energy consumption, daylighting technologies such as light ducts are becoming increasingly important. However, conventional light ducts have limitations, such as light loss, uneven illumination, and spectral distortion as the transmission distance increases, restricting the development of [...] Read more.
Due to the recent increase in building energy consumption, daylighting technologies such as light ducts are becoming increasingly important. However, conventional light ducts have limitations, such as light loss, uneven illumination, and spectral distortion as the transmission distance increases, restricting the development of a comfortable lighting environment. This study developed technical alternatives for transmission and diffusion parts to overcome these limitations and improve the daylighting performance of light ducts. The performance of these alternatives was verified through testbed experiments. The proposed light duct design minimized light loss through the arrangement of multiple relay lenses in series in the transmission part and improved indoor illuminance uniformity in the diffusion part using a double-reflection structure with upper and lower reflectors. Consequently, for a transmission distance of 20 m, the average illuminance increased by ~27.3% and the uniformity improved by an average of 47.8% compared to a conventional plastic optical fiber (POF)-based light duct. Even under intense summer sunlight conditions, a transmission distance of 30 m showed a high useful daylighting illuminance (UDI) ratio and considerbly reduced glare risk, indicating characteristics favorable for maintaining a comfortable visual environment. Furthermore, the proposed light duct exhibited a spectral distribution similar to that of outdoor sunlight, demonstrating the potential to ensure the continuous spectral characteristics of natural light transmitted indoors. Finally, it also exhibited the potential to maintain its higher daylighting performance even at a transmission distance of 30 m compared to conventional technology. Full article
(This article belongs to the Special Issue Optimal Design of Lighting/Daylighting in Buildings)
►▼ Show Figures

Figure 1

17 pages, 2643 KB  
Article
MCPA Optical Fiber Sensors via Molecularly Imprinted Polymers Combined with Intensity-Based and Plasmonic Platforms
by Ines Tavoletta, Francesco Arcadio, Luigi Zeni, Ricardo Oliveira, Rogério Nunes Nogueira, Giancarla Alberti and Nunzio Cennamo
Polymers 2025, 17(22), 3048; https://doi.org/10.3390/polym17223048 - 17 Nov 2025
Viewed by 998
Abstract
Two low-cost optical–chemical sensors based on plastic optical fibers (POFs) and molecularly imprinted polymers (MIPs) are developed and tested for the detection of 4-chloro-2-methylphenoxyacetic acid (MCPA), a herbicide of great interest in environmental monitoring. The first sensor is based on an optical splitter [...] Read more.
Two low-cost optical–chemical sensors based on plastic optical fibers (POFs) and molecularly imprinted polymers (MIPs) are developed and tested for the detection of 4-chloro-2-methylphenoxyacetic acid (MCPA), a herbicide of great interest in environmental monitoring. The first sensor is based on an optical splitter composed of two modified POFs coupled with an MIP for measuring MCPA. The second type of sensor is based on a surface plasmon resonance (SPR) D-shaped POF platform combined with the same MIP receptor for MCPA. The two proposed polymer-based sensors, exploiting different optical phenomena, were tested using similar equipment, consisting of white light sources and spectrometers. The experimental results show that both MCPA sensors present high selectivity for the target analyte and similar performances in terms of detection limits (LODs) of 3 nM and detection ranges (between 3 nM and 500 nM) by exploiting the MIP’s sites with a similar affinity constant. The polymer-based sensors exhibited better performances than those achieved by the electrochemical technique combined with the same MIP presented in the literature. Then, tests performed on real samples demonstrated good recovery values (between 82% and 116%), assessing the applicability of both sensors in real-world scenarios. Moreover, the POF-MIP splitter sensor configuration can be fabricated without expensive fabrication steps, such as spinning and sputtering processes. Full article
(This article belongs to the Section Polymer Applications)
►▼ Show Figures

Figure 1

12 pages, 2709 KB  
Article
An Attomolar-Level Optical Device for Monitoring Receptor–Analyte Interactions Without Functionalization Steps: A Case Study of Cytokine Detection
by Nunzio Cennamo, Francesco Arcadio, Chiara Marzano, Rosalba Pitruzzella, Mimimorena Seggio, Maria Pesavento, Stefano Toldo, Antonio Abbate and Luigi Zeni
Sensors 2025, 25(3), 930; https://doi.org/10.3390/s25030930 - 4 Feb 2025
Cited by 4 | Viewed by 3126
Abstract
A plastic optical fiber (POF)-based device for biosensing strategies has been developed to monitor several protein–protein interactions at ultra-low concentrations without functionalization processes, exploiting plasmonic phenomena. In this work, novel tests were applied to different kinds of analyte–receptor interactions, such as interleukins, where [...] Read more.
A plastic optical fiber (POF)-based device for biosensing strategies has been developed to monitor several protein–protein interactions at ultra-low concentrations without functionalization processes, exploiting plasmonic phenomena. In this work, novel tests were applied to different kinds of analyte–receptor interactions, such as interleukins, where the bioreceptor’s (protein antibody) molecular weight is roughly ten times that of the analyte (protein interleukin), while intracellular bioreceptors and small molecules at low molecular weight interactions have already been demonstrated via the same point-of-care test (POCT). The POCT was implemented by a white light source and a spectrometer connected via two POF-based chips connected in series: an innovative microcuvette chip and a D-shaped POF surface plasmon resonance (SPR) probe. In particular, the POF microcuvette chip was achieved by drilling three micro holes in the core of a modified POF. Instead of performing a functionalization step, the micro holes were filled with a specific receptor solution for the analyte (one microliter at the femtomolar level), which selectively captured the target (e.g., cytokine) when the samples were dropped over the filled micro holes (twenty microliters at the attomolar level). Three interleukins, IL-1β, IL-17A, and IL-18, were detected in the attomolar concentrations range by monitoring the resonance wavelength shift over time due to the cytokine/antibody (protein–protein) interaction. The POF-based device was proven to be effective for detecting several interleukins at the attomolar level in a few minutes and without functionalization processes. Full article
(This article belongs to the Special Issue Advanced Optics and Photonics Technologies for Sensing Applications)
►▼ Show Figures

Figure 1

18 pages, 3739 KB  
Article
An MIP-Based PFAS Sensor Exploiting Nanolayers on Plastic Optical Fibers for Ultra-Wide and Ultra-Low Detection Ranges—A Case Study of PFAS Detection in River Water
by Rosalba Pitruzzella, Alessandro Chiodi, Riccardo Rovida, Francesco Arcadio, Giovanni Porto, Simone Moretti, Gianfranco Brambilla, Luigi Zeni and Nunzio Cennamo
Nanomaterials 2024, 14(21), 1764; https://doi.org/10.3390/nano14211764 - 3 Nov 2024
Cited by 15 | Viewed by 5740
Abstract
In this work, a novel optical–chemical sensor for the detection of per- and polyfluorinated substances (PFASs) in a real scenario is presented. The proposed sensing approach exploits the multimode characteristics of plastic optical fibers (POFs) to achieve unconventional sensors via surface plasmon resonance [...] Read more.
In this work, a novel optical–chemical sensor for the detection of per- and polyfluorinated substances (PFASs) in a real scenario is presented. The proposed sensing approach exploits the multimode characteristics of plastic optical fibers (POFs) to achieve unconventional sensors via surface plasmon resonance (SPR) phenomena. The sensor is realized by the coupling of an SPR-POF platform with a novel chemical chip based on different polymeric nanolayers over the core of a D-shaped POF, one made up of an optical adhesive and one of a molecularly imprinted polymer (MIP) for PFAS. The chemical chip is used to launch the light into the SPR D-shaped POF platform, so the interaction between the analyte and the MIP’s sites can be used to modulate the propagated light in the POFs and the SPR phenomena. Selectivity tests and dose–response curves by standard PFOA water solutions were carried out to characterize the detection range sensor response, obtaining a wide PFAS response range, from 1 ppt to 1000 ppt. Then, tests performed on river water samples collected from the Bormida river paved the way for the applicability of the proposed approach to a real scenario. Full article
►▼ Show Figures

Figure 1

15 pages, 2261 KB  
Article
Optical Fiber Technology for Efficient Daylighting and Thermal Control: A Sustainable Approach for Buildings
by Lokesh Udhwani, Archana Soni, Erdem Cuce and Sudhakar Kumarasamy
Eng 2024, 5(4), 2680-2694; https://doi.org/10.3390/eng5040140 - 18 Oct 2024
Cited by 10 | Viewed by 5702
Abstract
Different direct solar harvesting systems for daylighting are being explored to achieve high uniform illumination deep within buildings at minimal cost. A promising solution to make these systems cost-effective is the use of plastic optical fibers (POFs). However, heat-related issues with low-cost POFs [...] Read more.
Different direct solar harvesting systems for daylighting are being explored to achieve high uniform illumination deep within buildings at minimal cost. A promising solution to make these systems cost-effective is the use of plastic optical fibers (POFs). However, heat-related issues with low-cost POFs need to be addressed for the widespread adoption of efficient daylighting technologies. Previous studies have explored solutions for this overheating problem, but their effectiveness remains uncertain. This study proposes a low-cost fiber optic daylighting system integrated with a newly patented mechanical component designed to secure the fiber optic bundle at the focal point, providing three levels of heat filtration while ensuring uniform illumination. Our methodology involves selecting a small area, installing the setup, and measuring both heat and light readings, followed by validation through software simulations. The operational principle of this technology is explained, and experimental tests using lux meters and infrared thermometers were conducted to investigate the system’s characteristics. The three-level heat filtration device reduces temperature by approximately 35 °C at the surface of the optical fiber, and the average illumination of the room is around 400 lux. These results were further verified using RELUX simulation software. The findings demonstrate the promising potential of this new device in solar heat filtration and achieving uniform illumination. Recommendations for mitigating overheating damage and exploring heat filtering possibilities in new parabolic solar daylighting systems for further research are also provided. Full article
(This article belongs to the Special Issue Feature Papers in Eng 2024)
►▼ Show Figures

Figure 1

18 pages, 3070 KB  
Article
An Optical Device Based on a Chemical Chip and Surface Plasmon Platform for 2-Furaldehyde Detection in Insulating Oil
by Letizia De Maria, Francesco Arcadio, Giuseppe Gabetta, Daniele Merli, Giancarla Alberti, Luigi Zeni, Nunzio Cennamo and Maria Pesavento
Sensors 2024, 24(16), 5261; https://doi.org/10.3390/s24165261 - 14 Aug 2024
Cited by 3 | Viewed by 2087
Abstract
2-Furaldehyde (2-FAL) is one of the main by-products of the degradation of hemicellulose, which is the solid material of the oil–paper insulating system of oil-filled transformers. For this reason, it has been suggested as a marker of the degradation of the insulating system; [...] Read more.
2-Furaldehyde (2-FAL) is one of the main by-products of the degradation of hemicellulose, which is the solid material of the oil–paper insulating system of oil-filled transformers. For this reason, it has been suggested as a marker of the degradation of the insulating system; sensing devices for 2-FAL analysis in a wide concentration range are of high interest in these systems. An optical sensor system is proposed; this consists of a chemical chip, able to capture 2-FAL from the insulating oil, coupled with a surface plasmon resonance (SPR) probe, both realized on multimode plastic optical fibers (POFs). The SPR platform exploits gold nanofilm or, alternatively, a double layer of gold and silicon oxide to modulate the sensor sensitivity. The capturing chip is always based on the same molecularly imprinted polymer (MIP) as a receptor specific for 2-FAL. The system with the SPR probe based on a gold nanolayer had a higher sensitivity and a lower detection limit of fractions of μg L−1. Instead, the SPR probe, based on a double layer (gold and silicon oxide), has a lower sensitivity with a worse detection limit, and it is suitable for the detection of 2-FAL at concentrations of 0.01–1 mg L−1. Full article
►▼ Show Figures

Figure 1

12 pages, 2991 KB  
Article
An Efficient Bio-Receptor Layer Combined with a Plasmonic Plastic Optical Fiber Probe for Cortisol Detection in Saliva
by Francesco Arcadio, Mimimorena Seggio, Rosalba Pitruzzella, Luigi Zeni, Alessandra Maria Bossi and Nunzio Cennamo
Biosensors 2024, 14(7), 351; https://doi.org/10.3390/bios14070351 - 19 Jul 2024
Cited by 15 | Viewed by 3869
Abstract
Cortisol is a clinically validated stress biomarker that takes part in many physiological and psychological functions related to the body’s response to stress factors. In particular, it has emerged as a pivotal tool for understanding stress levels and overall well-being. Usually, in clinics, [...] Read more.
Cortisol is a clinically validated stress biomarker that takes part in many physiological and psychological functions related to the body’s response to stress factors. In particular, it has emerged as a pivotal tool for understanding stress levels and overall well-being. Usually, in clinics, cortisol levels are monitored in blood or urine, but significant changes are also registered in sweat and saliva. In this work, a surface plasmon resonance probe based on a D-shaped plastic optical fiber was functionalized with a glucocorticoid receptor exploited as a highly efficient bioreceptor specific to cortisol. The developed plastic optical fiber biosensor was tested for cortisol detection in buffer and artificial saliva. The biosensor response showed very good selectivity towards other hormones and a detection limit of about 59 fM and 96 fM in phosphate saline buffer and artificial saliva, respectively. The obtained detection limit, with a rapid detection time (about 5 min) and a low-cost sensor system, paved the way for determining the cortisol concentration in saliva samples without any extraction process or sample pretreatment via a point-of-care test. Full article
(This article belongs to the Special Issue Plasmonic Biosensors for Biomedical Applications)
►▼ Show Figures

Figure 1

13 pages, 3119 KB  
Article
Plasmonic Optical Fiber Sensors and Molecularly Imprinted Polymers for Glyphosate Detection at an Ultra-Wide Range
by Luca Pasquale Renzullo, Ines Tavoletta, Giancarla Alberti, Luigi Zeni, Maria Pesavento and Nunzio Cennamo
Chemosensors 2024, 12(7), 142; https://doi.org/10.3390/chemosensors12070142 - 17 Jul 2024
Cited by 7 | Viewed by 2805
Abstract
In this study, a surface plasmon resonance (SPR) sensor based on modified plastic optical fibers (POFs) was combined with a specific molecularly imprinted polymer (MIP), used as a synthetic receptor, for glyphosate (GLY) determination in aqueous solutions. Since GLY is a non-selective herbicide [...] Read more.
In this study, a surface plasmon resonance (SPR) sensor based on modified plastic optical fibers (POFs) was combined with a specific molecularly imprinted polymer (MIP), used as a synthetic receptor, for glyphosate (GLY) determination in aqueous solutions. Since GLY is a non-selective herbicide associated with severe environmental and health problems, detecting glyphosate in environmental and biological samples remains challenging. The selective interaction between the MIP layer and GLY is monitored by exploiting the SPR phenomenon at the POF’s gold surface. Experimental results show that in about ten minutes and by dropping microliter volume samples, the presented optical–chemical sensor can quantify up to three orders of magnitude of GLY concentrations, from nanomolar to micromolar, due to a thin MIP layer over the SPR surface. The developed optical–chemical sensor presents a detection limit of about 1 nM and can be used for onsite GLY measurements. Moreover, the experimental analysis demonstrated the high selectivity of the proposed POF-based chemical sensor. Full article
►▼ Show Figures

Figure 1

Back to TopTop