Sign in to use this feature.

Years

Between: -

Subjects

remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline

Journals

Article Types

Countries / Regions

Search Results (40)

Search Parameters:
Keywords = miniaturized tomography

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
28 pages, 762 KB  
Review
Next-Generation Wearable fNIRS: A Comprehensive Review of Bio-Instrumentation and Hardware Architectures
by Anusha Upadhyay and Manob Jyoti Saikia
Appl. Sci. 2026, 16(11), 5368; https://doi.org/10.3390/app16115368 - 27 May 2026
Cited by 1 | Viewed by 1173
Abstract
Comprehensive monitoring of cerebral hemodynamics has led to significant advances in Functional Near-Infrared Systems (fNIRS), particularly in terms of hardware design and development of wearable platforms. These advancements have established fNIRS devices as valuable tools in research and clinical practices; however, most existing [...] Read more.
Comprehensive monitoring of cerebral hemodynamics has led to significant advances in Functional Near-Infrared Systems (fNIRS), particularly in terms of hardware design and development of wearable platforms. These advancements have established fNIRS devices as valuable tools in research and clinical practices; however, most existing literature focuses predominantly on clinical applications or high-level system performance. This review provides a rigorous, bottom-up analysis of bio-instrumentation architectures, evaluating the low-level trade-offs in component selection and circuit design that define modern wearable fNIRS performance. In this paper, we have identified and compared key hardware components of modern fNIRS technologies, including optical sensors, signal conditioning elements, control units, power systems, and communication modules. Significant progress has been made in terms of optical tomography, head coverage and conformity, multimodal integration, hyperscanning, motion tolerance, user comfort, and miniaturization. The paper underscores how systems may have unique architectures although they follow the same foundational principle. It also aims to identify the trade-offs existing in current fNIRS devices. Overall, this paper presents an overview of where we stand in terms of fNIRS development and attempts to trace an outline of the next generation of devices. Full article
(This article belongs to the Section Computing and Artificial Intelligence)
Show Figures

Figure 1

16 pages, 3451 KB  
Article
A Compact SLED Light Source Driver Module for Optical Coherence Tomography Applications
by Yuanhao Cao, Feng Liu, Jianguo Mei, Qun Liu and Biao Chen
Sensors 2026, 26(7), 2084; https://doi.org/10.3390/s26072084 - 27 Mar 2026
Viewed by 692
Abstract
Optical coherence tomography (OCT) is a non-invasive, high-resolution imaging technique widely used in medical diagnosis, biomedical research and other fields. It plays an important role in the early detection and accurate diagnosis of diseases. The superluminescent light-emitting diode (SLED) is the ideal light [...] Read more.
Optical coherence tomography (OCT) is a non-invasive, high-resolution imaging technique widely used in medical diagnosis, biomedical research and other fields. It plays an important role in the early detection and accurate diagnosis of diseases. The superluminescent light-emitting diode (SLED) is the ideal light source for OCT systems, where the stability of its drive current and operating temperature directly determines the imaging quality of OCT. Existing driving and temperature control schemes for similar light sources predominantly rely on microcontrollers or field programmable gate arrays (FPGAs), a reliance which often results in complex system architectures and difficulties in balancing simplicity with control precision. To address these issues, a stable and compact SLED source driver module designed for OCT was developed in this study, integrating both a constant-current drive circuit and a temperature control circuit. The negative feedback control and improved current-limiting protection are employed in the constant-current drive circuit to maintain stable SLED operation and reduce the circuit footprint. A miniature dedicated temperature control chip is adopted in the temperature control circuit. The operating temperature of the SLED is acquired by linearizing the negative temperature coefficient (NTC) thermistor value and regulated through a proportional-integral-derivative (PID) compensation circuit. The size of the fabricated module (including casing) is less than 10 × 8 × 3 cm3. Experimental results show that the driver module achieves a drive current control accuracy of 0.1% and a temperature control accuracy of 0.01 °C. The output optical power fluctuation is less than 0.005 mW and the average axial resolution for OCT is 6.5992 μm with a standard deviation of 0.0107 μm. This light source driver module successfully balances control precision with structural simplicity, demonstrating excellent applicability in OCT systems. Full article
(This article belongs to the Special Issue Optical Sensors for Biomedical Diagnostics and Monitoring)
Show Figures

Figure 1

25 pages, 7838 KB  
Review
Optical Biosensors for Blood Coagulation Monitoring: Advantages, Limitations, and Translational Potential
by Zichen Wang, Gaohong Di and Jing Wang
Biosensors 2026, 16(2), 123; https://doi.org/10.3390/bios16020123 - 16 Feb 2026
Viewed by 968
Abstract
Dynamic monitoring of hemostatic equilibrium is indispensable for clinical safety in high-risk scenarios, while current clinical methods are limited by sample volume, detection speed, and physiological relevance. These shortcomings underscore the demand for novel sensing platforms. Optical biosensors, leveraging label-free detection, rapid response, [...] Read more.
Dynamic monitoring of hemostatic equilibrium is indispensable for clinical safety in high-risk scenarios, while current clinical methods are limited by sample volume, detection speed, and physiological relevance. These shortcomings underscore the demand for novel sensing platforms. Optical biosensors, leveraging label-free detection, rapid response, and multi-level characterization, could serve as a transformative solution for decentralized and point-of-care monitoring. This review systematically summarizes advances in optical coagulation testing, encompassing light transmission aggregometry, laser speckle rheology, optical coherence tomography/elastography, optic–acoustic coupled methods, and fluorescence biosensing. These technologies complementarily capture structural and mechanical and some molecular and cellular dynamics of coagulation, bridging gaps in traditional assays. Despite promising preclinical and clinical correlations, translation barriers persist in lack of standardization of metrics, interference mitigation, and multi-center validation in diverse patient cohorts. Future development of optical biosensing platforms for coagulation testing should focus on modular integration, AI-aided interference correction, and microfluidic miniaturization to realize actionable, real-time coagulation assessment. Optical biosensors hold unparalleled potential to transform hemostatic monitoring from static endpoint testing to dynamic, interpretable evaluation, guiding personalized clinical decisions. Full article
(This article belongs to the Section Optical and Photonic Biosensors)
Show Figures

Graphical abstract

27 pages, 5697 KB  
Review
Optical Non-Invasive Glucose Monitoring Using Aqueous Humor: A Review
by Haolan Xi and Yiqing Gong
Sensors 2025, 25(13), 4236; https://doi.org/10.3390/s25134236 - 7 Jul 2025
Cited by 5 | Viewed by 6275
Abstract
This review explores optical technologies for non-invasive glucose monitoring (NIGM) using aqueous humor (AH) as media, addressing the limitations of traditional invasive methods in diabetes management. It analyzes key techniques such as Raman spectroscopy, polarimetry, and mid- and near-infrared spectral methods, highlighting their [...] Read more.
This review explores optical technologies for non-invasive glucose monitoring (NIGM) using aqueous humor (AH) as media, addressing the limitations of traditional invasive methods in diabetes management. It analyzes key techniques such as Raman spectroscopy, polarimetry, and mid- and near-infrared spectral methods, highlighting their respective challenges, alongside emerging hybrid approaches like photoacoustic spectroscopy and optical coherence tomography. Crucially, the practical realization of these optical methods for portable NIGM hinges on advanced instrumentation. Therefore, this review also details progress in compact NIR spectrometers. While conventional systems often lack suitability, significant advancements in on-chip technologies—including miniaturized dispersive spectrometers and various on-chip Fourier transform systems (e.g., spatial heterodyne, stationary wave integral, and temporally modulated FT systems)—utilizing integration platforms like SOI and SiN are promising. Such innovations offer the potential for high spectral resolution, large bandwidth, and miniaturization, which are essential for developing practical AH-based NIGM systems to improve diabetes care. Full article
(This article belongs to the Special Issue Advances in Miniaturization and Power Efficiency of Optical Sensors)
Show Figures

Figure 1

20 pages, 4557 KB  
Article
Assessment of the Feasibility of Using Additive Manufacturing from Metal Powder to Produce Compact Heat Exchangers
by Katarzyna Chliszcz, Dorota Laskowska, Waldemar Kuczyński, Błażej Bałasz, Maciej Kasperowaicz and Kevin Moj
Materials 2025, 18(13), 3035; https://doi.org/10.3390/ma18133035 - 26 Jun 2025
Cited by 1 | Viewed by 2001
Abstract
The miniaturization of heat exchangers requires advanced manufacturing methods, as conventional techniques such as milling or casting are insufficient for producing complex microscale geometries. This study investigates the feasibility of using selective laser melting (SLM) with 316L stainless steel powder to fabricate compact [...] Read more.
The miniaturization of heat exchangers requires advanced manufacturing methods, as conventional techniques such as milling or casting are insufficient for producing complex microscale geometries. This study investigates the feasibility of using selective laser melting (SLM) with 316L stainless steel powder to fabricate compact heat exchangers with minichannels. The exchanger was designed using Autodesk Inventor 2023.3 software and produced under optimized process parameters. Measurements using a hydrostatic balance demonstrated that the applied process parameters resulted in a relative material density of 99.5%. The average microhardness in the core region of the SLM-fabricated samples was 255 HV, and the chemical composition of the final material differed only slightly from that of the feedstock material (stainless steel powder). Dimensional accuracy, surface quality, and internal structure integrity were assessed using computed tomography, optical microscopy, and contact profilometry. The fabricated component demonstrated high geometric fidelity and channel permeability, with local surface deformations associated with the absence of support structures. The average surface roughness (Ra) of the minichannels was 11.11 ± 1.63 µm. The results confirm that SLM technology enables the production of functionally viable heat exchangers with complex geometries. However, limitations remain regarding dimensional accuracy, powder removal, and surface roughness. These findings highlight the potential of metal additive manufacturing for heat transfer applications while emphasizing the need for further research on performance testing under real operating conditions, especially involving two-phase flow. Full article
Show Figures

Figure 1

23 pages, 4431 KB  
Review
Early Detection and Monitoring of Nephrolithiasis: The Potential of Electrochemical Sensors
by Kaiqiang Sun, Ningbin Zhao, Peizheng Shi, Zhuang Sun, Chen Ye, Li Fu, Dan Dai, Wubo Chu, Tao Cai, Hsu-Sheng Tsai and Cheng-Te Lin
Sensors 2025, 25(8), 2547; https://doi.org/10.3390/s25082547 - 17 Apr 2025
Cited by 4 | Viewed by 2988
Abstract
Nephrolithiasis (kidney stone disease) continues to pose a significant global health challenge, affecting millions of individuals and placing substantial economic pressures on healthcare systems. Traditional diagnostic methods—such as computed tomography (CT), ultrasound, and basic urinalysis—are often limited by issues including radiation exposure, lower [...] Read more.
Nephrolithiasis (kidney stone disease) continues to pose a significant global health challenge, affecting millions of individuals and placing substantial economic pressures on healthcare systems. Traditional diagnostic methods—such as computed tomography (CT), ultrasound, and basic urinalysis—are often limited by issues including radiation exposure, lower sensitivity in detecting small stones, operator dependency, and the inability to provide real-time analysis. In response, electrochemical sensors have emerged as innovative and powerful tools capable of the rapid, sensitive, and specific detection of key biomarkers associated with nephrolithiasis. This review highlights the advances in electrochemical approaches for monitoring oxalate and uric acid, the two primary metabolites implicated in kidney stone formation. We discuss the principles of electrode design and fabrication, including nanomaterial integration, 3D printing, and molecular imprinting, which have markedly improved detection limits and selectivity. Furthermore, we critically evaluate the practical challenges—such as sensor fouling, reproducibility, and stability in complex biological matrices—that currently impede widespread clinical implementation. The potentials for miniaturization and point-of-care integration are emphasized, with an eye toward continuous or home-based monitoring systems that can offer personalized insights into risk of stone formation and progression. By consolidating recent findings and exploring future trends in multi-analyte detection and wearable diagnostics, this review provides a roadmap for translating electrochemical sensors from research laboratories to routine clinical practice, ultimately aiming to enhance early intervention and improve patient outcomes in nephrolithiasis. Full article
(This article belongs to the Special Issue Feature Papers in Biosensors Section 2025)
Show Figures

Graphical abstract

13 pages, 3590 KB  
Article
A Precessing-Coin-like Rotary Actuator for Distal Endoscope Scanners: Proof-of-Concept Study
by Nirvana Gharib, Mohammad Reza Yousefi Darestani and Kenichi Takahata
Micromachines 2025, 16(1), 111; https://doi.org/10.3390/mi16010111 - 20 Jan 2025
Cited by 1 | Viewed by 2580
Abstract
This paper presents, for the first time, a rotary actuator functionalized by an inclined disc rotor that serves as a distal optical scanner for endoscopic probes, enabling side-viewing endoscopy in luminal organs using different imaging/analytic modalities such as optical coherence tomography and Raman [...] Read more.
This paper presents, for the first time, a rotary actuator functionalized by an inclined disc rotor that serves as a distal optical scanner for endoscopic probes, enabling side-viewing endoscopy in luminal organs using different imaging/analytic modalities such as optical coherence tomography and Raman spectroscopy. This scanner uses a magnetic rotor designed to have a mirror surface on its backside, being electromagnetically driven to roll around the cone-shaped hollow base to create a motion just like a precessing coin. An optical probing beam directed from the probe’s optic fiber is passed through the hollow cone to be incident and bent on the back mirror of the rotating inclined rotor, circulating the probing beam around the scanner for full 360° sideway imaging. This new scanner architecture removes the need for a separate prism mirror and holding mechanics to drastically simplify the scanner design and thus, potentially enhancing device miniaturization and reliability. The first proof-of-concept is developed using 3D printing and experimentally analyzed to reveal the ability of both angular stepping at 45° and high-speed rotation up to 1500 rpm within the biologically safe temperature range, a key function for multimodal imaging. Preliminary optical testing demonstrates continuous circumferential scanning of the laser beam with no blind spot caused by power leads to the actuator. The results indicate the fundamental feasibility of the developed actuator as an endoscopic distal scanner, a significant step to further development toward advancing optical endoscope technology. Full article
(This article belongs to the Special Issue MEMS Actuators and Their Applications)
Show Figures

Figure 1

16 pages, 13238 KB  
Article
Transfer of Periodic Phenomena in Multiphase Capillary Flows to a Quasi-Stationary Observation Using U-Net
by Bastian Oldach, Philipp Wintermeyer and Norbert Kockmann
Computers 2024, 13(9), 230; https://doi.org/10.3390/computers13090230 - 13 Sep 2024
Cited by 1 | Viewed by 1587
Abstract
Miniaturization promotes the efficiency and exploration domain in scientific fields such as computer science, engineering, medicine, and biotechnology. In particular, the field of microfluidics is a flourishing technology, which deals with the manipulation of small volumes of liquid. Dispersed droplets or bubbles in [...] Read more.
Miniaturization promotes the efficiency and exploration domain in scientific fields such as computer science, engineering, medicine, and biotechnology. In particular, the field of microfluidics is a flourishing technology, which deals with the manipulation of small volumes of liquid. Dispersed droplets or bubbles in a second immiscible liquid are of great interest for screening applications or chemical and biochemical reactions. However, since very small dimensions are characterized by phenomena that differ from those at macroscopic scales, a deep understanding of physics is crucial for effective device design. Due to small volumes in miniaturized systems, common measurement techniques are not applicable as they exceed the dimensions of the device by a multitude. Hence, image analysis is commonly chosen as a method to understand ongoing phenomena. Artificial Intelligence is now the state of the art for recognizing patterns in images or analyzing datasets that are too large for humans to handle. X-ray-based Computer Tomography adds a third dimension to images, which results in more information, but ultimately, also in more complex image analysis. In this work, we present the application of the U-Net neural network to extract certain states during droplet formation in a capillary, which forms a constantly repeated process that is captured on tens of thousands of CT images. The experimental setup features a co-flow setup that is based on 3D-printed capillaries with two different cross-sections with an inner diameter, respectively edge length of 1.6 mm. For droplet formation, water was dispersed in silicon oil. The classification into different droplet states allows for 3D reconstruction and a time-resolved 3D analysis of the present phenomena. The original U-Net was modified to process input images of a size of 688 × 432 pixels while the structure of the encoder and decoder path feature 23 convolutional layers. The U-Net consists of four max pooling layers and four upsampling layers. The training was performed on 90% and validated on 10% of a dataset containing 492 images showing different states of droplet formation. A mean Intersection over Union of 0.732 was achieved for a training of 50 epochs, which is considered a good performance. The presented U-Net needs 120 ms per image to process 60,000 images to categorize emerging droplets into 24 states at 905 angles. Once the model is trained sufficiently, it provides accurate segmentation for various flow conditions. The selected images are used for 3D reconstruction enabling the 2D and 3D quantification of emerging droplets in capillaries that feature circular and square cross-sections. By applying this method, a temporal resolution of 25–40 ms was achieved. Droplets that are emerging in capillaries with a square cross-section become bigger under the same flow conditions in comparison to capillaries with a circular cross section. The presented methodology is promising for other periodic phenomena in different scientific disciplines that focus on imaging techniques. Full article
Show Figures

Figure 1

12 pages, 6554 KB  
Article
Two-Step PM Procedure for Fabrication of Super-Engineering Plastic Gears
by Tatsuhiko Aizawa, Tomohiro Miyata and Kiyoyuki Endoh
Machines 2024, 12(3), 174; https://doi.org/10.3390/machines12030174 - 4 Mar 2024
Cited by 2 | Viewed by 2435
Abstract
The two-step PM (powder metallurgy)-route procedure was proposed to fabricate a super-engineering plastic gear directly from powder feedstock. Its lightweight, fully dense integrity and high-stiffness has been found to be suitable for reducers in robotics and electric vehicles, as they work even in [...] Read more.
The two-step PM (powder metallurgy)-route procedure was proposed to fabricate a super-engineering plastic gear directly from powder feedstock. Its lightweight, fully dense integrity and high-stiffness has been found to be suitable for reducers in robotics and electric vehicles, as they work even in severe environmental conditions. In this study, the green compaction and sinter-forging processes were used to consolidate the polyimide powder feedstock and to sinter forge the solid preform into the final products. To demonstrate the high density of preforms and sinter-forged gears, a hardness measurement and X-ray computer tomography were employed. The gear-grade balancing was also evaluated to describe the effect of fine sinter-forging conditions on the dimensional quality of polyimide gears. High gear grade with JIS-2 class proved that the polyimide was useful as a matrix of lightweight and high-strength gears. Full article
(This article belongs to the Section Advanced Manufacturing)
Show Figures

Figure 1

19 pages, 8287 KB  
Article
Vertical Distribution Mapping for Methane Fugitive Emissions Using Laser Path-Integral Sensing in Non-Cooperative Open Paths
by Di Wang, Yushuang Li, Yu Pu, Yan Lv, Mingji Wang, Hui Yang, Xuefeng Zhao and Dong Li
Sensors 2024, 24(4), 1307; https://doi.org/10.3390/s24041307 - 18 Feb 2024
Cited by 4 | Viewed by 3298
Abstract
Observing the vertical diffusion distribution of methane fugitive emissions from oil/gas facilities is significant for predicting the pollutant’s spatiotemporal transport and quantifying the random emission sources. A method is proposed for methane’s vertical distribution mapping by combining the laser path-integral sensing in non-non-cooperative [...] Read more.
Observing the vertical diffusion distribution of methane fugitive emissions from oil/gas facilities is significant for predicting the pollutant’s spatiotemporal transport and quantifying the random emission sources. A method is proposed for methane’s vertical distribution mapping by combining the laser path-integral sensing in non-non-cooperative open paths and the computer-assisted tomography (CAT) techniques. It uses a vertical-plume-mapping optical path configuration and adapts the developed dynamic relaxation and simultaneous algebraic reconstruction technique (DR-SART) into methane-emission-distribution reconstruction. A self-made miniaturized TDLAS telemetry sensor provides a reliable path to integral concentration information in non-non-cooperative open paths, with Allan variance analysis yielding a 3.59 ppm·m sensitivity. We employed a six-indexes system for the reconstruction performance analysis of four potential optical path-projection configurations and conducted the corresponding validation experiment. The results have shown that that of multiple fan-beams combined with parallel-beam modes (MFPM) is better than the other optical path-projection configurations, and its reconstruction similarity coefficient (ε) is at least 22.4% higher. For the different methane gas bag-layout schemes, the reconstruction errors of maximum concentration (γm) are consistently around 0.05, with the positional errors of maximum concentration (δ) falling within the range of 0.01 to 0.025. Moreover, considering the trade-off between scanning duration and reconstruction accuracy, it is recommended to appropriately extend the sensor measurement time on a single optical path to mitigate the impact of mechanical vibrations induced by scanning motion. Full article
(This article belongs to the Special Issue Optical Sensing for Environmental Monitoring—2nd Edition)
Show Figures

Figure 1

9 pages, 3910 KB  
Communication
A Miniaturized Electrothermal-MEMS-Based Optical Coherence Tomography (OCT) Handheld Microscope
by Qian Chen, Hui Zhao, Tingxiang Qi, Hua Wang and Huikai Xie
Photonics 2024, 11(1), 17; https://doi.org/10.3390/photonics11010017 - 26 Dec 2023
Cited by 6 | Viewed by 3688
Abstract
Swept-source optical coherence tomography (SS-OCT), benefiting from its high sensitivity, relatively large penetration depth, and non-contact and non-invasive imaging capability, is ideal for human skin imaging. However, limited by the size and performance of the reported optical galvanometer scanners, existing portable/handheld OCT probes [...] Read more.
Swept-source optical coherence tomography (SS-OCT), benefiting from its high sensitivity, relatively large penetration depth, and non-contact and non-invasive imaging capability, is ideal for human skin imaging. However, limited by the size and performance of the reported optical galvanometer scanners, existing portable/handheld OCT probes are still bulky, which makes continuously handheld imaging difficult. Here, we reported a miniaturized electrothermal-MEMS-based SS-OCT microscope that only weighs about 25 g and has a cylinder with a diameter of 15 mm and a length of 40 mm. This MEMS-based handheld imaging probe can achieve a lateral resolution of 25 μm, a 3D imaging time of 5 s, a penetration depth of up to 3.3 mm, and an effective imaging field of view (FOV) of 3 × 3 mm2. We have carried out both calibration plate and biological tissue imaging experiments to test the imaging performance of this microscope. OCT imaging of leaves, dragonfly, and human skin has been successfully obtained, showing the imaging performance and potential applications of this probe on human skin in the future. Full article
(This article belongs to the Special Issue Technologies and Applications of Biophotonics)
Show Figures

Figure 1

16 pages, 9988 KB  
Article
Line-Field Confocal Optical Coherence Tomography (LC-OCT) for Skin Imaging in Dermatology
by Flora Latriglia, Jonas Ogien, Clara Tavernier, Sébastien Fischman, Mariano Suppa, Jean-Luc Perrot and Arnaud Dubois
Life 2023, 13(12), 2268; https://doi.org/10.3390/life13122268 - 28 Nov 2023
Cited by 86 | Viewed by 11740
Abstract
Line-field confocal optical coherence tomography (LC-OCT) is a non-invasive optical imaging technique based on a combination of the principles of optical coherence tomography and reflectance confocal microscopy with line-field illumination, which can generate cell-resolved images of the skin in vivo. This article reports [...] Read more.
Line-field confocal optical coherence tomography (LC-OCT) is a non-invasive optical imaging technique based on a combination of the principles of optical coherence tomography and reflectance confocal microscopy with line-field illumination, which can generate cell-resolved images of the skin in vivo. This article reports on the LC-OCT technique and its application in dermatology. The principle of the technique is described, and the latest technological innovations are presented. The technology has been miniaturized to fit within an ergonomic handheld probe, allowing for the easy access of any skin area on the body. The performance of the LC-OCT device in terms of resolution, field of view, and acquisition speed is reported. The use of LC-OCT in dermatology for the non-invasive detection, characterization, and therapeutic follow-up of various skin pathologies is discussed. Benign and malignant melanocytic lesions, non-melanocytic skin tumors, such as basal cell carcinoma, squamous cell carcinoma and actinic keratosis, and inflammatory and infectious skin conditions are considered. Dedicated deep learning algorithms have been developed for assisting in the analysis of LC-OCT images of skin lesions. Full article
(This article belongs to the Special Issue Non-invasive Skin Imaging Development and Applications)
Show Figures

Figure 1

16 pages, 7434 KB  
Article
Path Planning and Navigation of Miniature Serpentine Robot for Bronchoscopy Application
by Cheng-Peng Kuan, Shu Huang, Hao-Yan Wu, An-Peng Wang and Chien-Yu Wu
Micromachines 2023, 14(5), 969; https://doi.org/10.3390/mi14050969 - 28 Apr 2023
Cited by 5 | Viewed by 3372
Abstract
The miniature serpentine robot can be applied to NOTES (Natural Orifice Transluminal Endoscopic Surgery). In this paper, a bronchoscopy application is addressed. This paper describes the basic mechanical design and control scheme of this miniature serpentine robotic bronchoscopy. In addition, off-line backward path [...] Read more.
The miniature serpentine robot can be applied to NOTES (Natural Orifice Transluminal Endoscopic Surgery). In this paper, a bronchoscopy application is addressed. This paper describes the basic mechanical design and control scheme of this miniature serpentine robotic bronchoscopy. In addition, off-line backward path planning and real-time and in situ forward navigation in this miniature serpentine robot are discussed. The proposed backward-path-planning algorithm utilizes the 3D model of a bronchial tree constructed from the synthetization of medical images such as images from CT (Computed Tomography), MRI (Magnetic Resonance Imaging), or X-ray, to define a series of nodes/events backward from the destination, for example, the lesion, to the original starting point, for example, the oral cavity. Accordingly, forward navigation is designed to make sure this series of nodes/events shall be passed/occur from the origin to the destination. This combination of backward-path planning and forward navigation does not require accurate positioning information of the tip of the miniature serpentine robot, which is where the CMOS bronchoscope is located. Collaboratively, a virtual force is introduced to maintain the tip of the miniature serpentine robot at the center of the bronchi. Results show that this method of path planning and navigation of the miniature serpentine robot for bronchoscopy applications works. Full article
(This article belongs to the Special Issue Recent Advances in Microrobotics)
Show Figures

Figure 1

14 pages, 7136 KB  
Article
Miniaturization of Non-Assembly Metallic Pin-Joints by LPBF-Based Additive Manufacturing as Perfect Pivots for Pantographic Metamaterials
by Florian Gutmann, Maximilian Stilz, Sankalp Patil, Frank Fischer, Klaus Hoschke, Georg Ganzenmüller and Stefan Hiermaier
Materials 2023, 16(5), 1797; https://doi.org/10.3390/ma16051797 - 22 Feb 2023
Cited by 8 | Viewed by 3129
Abstract
This work introduced additively manufactured non-assembly, miniaturized pin-joints for pantographic metamaterials as perfect pivots. The titanium alloy Ti6Al4V was utilized with laser powder bed fusion technology. The pin-joints were produced using optimized process parameters required for manufacturing miniaturized joints, and they were printed [...] Read more.
This work introduced additively manufactured non-assembly, miniaturized pin-joints for pantographic metamaterials as perfect pivots. The titanium alloy Ti6Al4V was utilized with laser powder bed fusion technology. The pin-joints were produced using optimized process parameters required for manufacturing miniaturized joints, and they were printed at a particular angle to the build platform. Additionally, this process optimization will eliminate the requirement to geometrically compensate the computer-aided design model, allowing for even further miniaturization. In this work, pin-joint lattice structures known as pantographic metamaterials were taken into consideration. The mechanical behavior of the metamaterial was characterized by bias extension tests and cyclic fatigue experiments, showing superior levels of performance (no sign of fatigue for 100 cycles of an elongation of approximately 20%) in comparison to classic pantographic metamaterials made with rigid pivots. The individual pin-joints, with a pin diameter of 350 to 670 µm, were analyzed using computed tomography scans, indicating that the mechanism of the rotational joint functions well even though the clearance of 115 to 132 µm between the moving parts is comparable to the nominal spatial resolution of the printing process. Our findings emphasize new possibilities to develop novel mechanical metamaterials with actual moving joints on a small scale. The results will also support stiffness-optimized metamaterials with variable-resistance torque for non-assembly pin-joints in the future. Full article
Show Figures

Figure 1

15 pages, 6373 KB  
Article
Analysis of Stress Relaxation in Bulk and Porous Ultra-High Molecular Weight Polyethylene (UHMWPE)
by Eugene S. Statnik, Alexey I. Salimon, Yulia E. Gorshkova, Natallia S. Kaladzinskaya, Ludmila V. Markova and Alexander M. Korsunsky
Polymers 2022, 14(24), 5374; https://doi.org/10.3390/polym14245374 - 8 Dec 2022
Cited by 6 | Viewed by 4257
Abstract
The reported study was devoted to the investigation of viscoelastic behavior for solid and porous ultra-high molecular weight polyethylene (UHMWPE) under compression. The obtained experimental stress curves were interpreted using a two-term Prony series to represent the superposition of two coexisting activation processes [...] Read more.
The reported study was devoted to the investigation of viscoelastic behavior for solid and porous ultra-high molecular weight polyethylene (UHMWPE) under compression. The obtained experimental stress curves were interpreted using a two-term Prony series to represent the superposition of two coexisting activation processes corresponding to long molecular (~160 s) and short structural (~20 s) time scales, respectively, leading to good statistical correlation with the observations. In the case of porous polymer, the internal strain redistribution during relaxation was quantified using digital image correlation (DIC) analysis. The strongly inhomogeneous deformation of the porous polymer was found not to affect the relaxation times. To illustrate the possibility of generalizing the results to three dimensions, X-ray tomography was used to examine the porous structure relaxation at the macro- and micro-scale levels. DIC analysis revealed positive correlation between the applied force and relative density. The apparent stiffness variation for UHMWPE foams with mixed open and closed cells was described using a newly proposed three-term expression. Furthermore, in situ tensile loading and X-ray scattering study was applied for isotropic solid UHMWPE specimens to investigate the evolution of internal structure and orientation during drawing and stress relaxation in another loading mode. Full article
(This article belongs to the Special Issue High-Performance Polyethylene)
Show Figures

Figure 1

Back to TopTop