Sign in to use this feature.

Years

Between: -

Subjects

remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline

Journals

Article Types

Countries / Regions

Search Results (20)

Search Parameters:
Keywords = microsphere tracking

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
12 pages, 4266 KB  
Article
A Study on Traceable Oxygen-Releasing Microspheres in Combination with Bone Marrow Mesenchymal Stem Cells to Enhance Skin Wound Healing
by Qianqian Wang, Xiangjie Li, Qing Xu, Yuan Xie, Wenyan Duan, Zhichao Ma and Xue Chen
Int. J. Mol. Sci. 2026, 27(11), 4916; https://doi.org/10.3390/ijms27114916 - 29 May 2026
Viewed by 400
Abstract
The treatment of full-thickness skin defects remains a major challenge in clinical medicine. Accelerating wound healing and promoting the restoration of tissue function are of paramount importance. Stem cell therapy has been applied in clinical practice to facilitate wound repair. However, the low [...] Read more.
The treatment of full-thickness skin defects remains a major challenge in clinical medicine. Accelerating wound healing and promoting the restoration of tissue function are of paramount importance. Stem cell therapy has been applied in clinical practice to facilitate wound repair. However, the low survival rate of transplanted stem cells in an ischemic and hypoxic microenvironment severely limits the effectiveness of their clinical application. Microspheres, owing to their excellent biocompatibility and drug delivery capabilities, can serve as effective carriers for oxygen transport. It is worthwhile to evaluate the timing and process of oxygen release under hypoxic conditions. In this study, core–shell structured oxygen-releasing microspheres were prepared and incorporated with the photosensitizer hypericin (HYP) to enable dynamic tracking of the oxygen release process via fluorescent signals. The effects of the oxygen-releasing microspheres on cells under hypoxic conditions were analyzed, focusing primarily on the characterization of the microspheres, their biocompatibility, luminescent properties, and oxygen-releasing capacity. Furthermore, the efficacy of the oxygen-releasing microspheres in combination with bone marrow mesenchymal stem cells (BMSCs) in promoting wound healing was evaluated in vivo. The results indicate that the addition of the microspheres improved cell survival rates in hypoxic environments; meanwhile, their luminescent properties demonstrated the potential of fluorescence intensity as a visual indicator of oxygen release. Full article
(This article belongs to the Section Molecular Biology)
Show Figures

Figure 1

16 pages, 7148 KB  
Article
Retention and Transport of Micro- and Nano-Particulates in RTM: TGA/SEM-Based Insight into Permeability Outcomes
by Ariel Stocchi, Luis A. Miccio, Exequiel Rodríguez and Gastón Francucci
J. Compos. Sci. 2026, 10(4), 215; https://doi.org/10.3390/jcs10040215 - 19 Apr 2026
Viewed by 730
Abstract
This work presents a comparative study of micro- and nano-scale fillers in liquid composite molding processes, focusing on how particle size and morphology affect resin rheology, flow behavior, and filler filtration within fiber preforms. Glass microspheres and organo-modified montmorillonite were dispersed in epoxy [...] Read more.
This work presents a comparative study of micro- and nano-scale fillers in liquid composite molding processes, focusing on how particle size and morphology affect resin rheology, flow behavior, and filler filtration within fiber preforms. Glass microspheres and organo-modified montmorillonite were dispersed in epoxy resin and injected through glass-mat preforms at different fiber volume fractions (ranging from 0.27 to 0.47). Our study integrates rheological characterization, in situ flow-front tracking, unsaturated permeability analysis, thermogravimetric quantification of retained particles, and microstructural observations by SEM. Despite their smaller loading, nanoclay suspensions showed a markedly higher viscosity increase than microsphere systems, yet their permeability remained nearly unchanged. In contrast, microsphere-filled resins exhibited strong filtration at the flow inlet, density-driven settling near the lower tool face, and significant permeability loss. The results demonstrate that nano-fillers, although more viscous, maintain homogeneous distribution and flow continuity, whereas micro-fillers promote cake formation and local compaction. This controlled side-by-side comparison clarifies how filler size and shape govern filtration mechanisms in liquid composite molding (LCM), providing design guidelines for processing filled resin systems without compromising part quality. Full article
(This article belongs to the Section Polymer Composites)
Show Figures

Figure 1

20 pages, 5643 KB  
Article
Stable Encapsulation and Responsive Release of Dyes via Noncovalent Molecular Lock Strategy: A Case Study of Rhodamine B Based Fluorescent Hydrogel Microspheres
by Shuo Meng, Chuanyu Dang, Xiaoyong Qiu, Jianhua Chen, Ruiheng Yao, Yuquan Wang, Luxing Wei, Jun Huang and Xiaolai Zhang
Polymers 2026, 18(4), 493; https://doi.org/10.3390/polym18040493 - 16 Feb 2026
Viewed by 944
Abstract
Hydrogel fluorescent microspheres function as versatile tracers with applications spanning across biomedicine, complex plasma systems, hydrodynamics, and drug delivery. However, the controlled release of fluorescent material in hydrogel microspheres is challenging to achieve. The fluorescent hydrogel microsphere (namely poly(ethylene glycol) diacrylate@rhodamine B-tannic acid, [...] Read more.
Hydrogel fluorescent microspheres function as versatile tracers with applications spanning across biomedicine, complex plasma systems, hydrodynamics, and drug delivery. However, the controlled release of fluorescent material in hydrogel microspheres is challenging to achieve. The fluorescent hydrogel microsphere (namely poly(ethylene glycol) diacrylate@rhodamine B-tannic acid, PEGDA@RhB-TA) was fabricated by incorporating tannic acid and RhB into PEGDA microspheres. The stable encapsulation and responsive release of RhB can be achieved by leveraging the non-covalent interactions between TA and RhB. RhB was stably encapsulated within PEGDA microspheres through noncovalent interactions (hydrophobic interactions, hydrogen bonding, π–π, and ion–π interactions) between RhB and TA. Both molecular dynamics simulations by GROMACS and experimental results confirmed the noncovalent binding mechanisms between RhB and TA. The microspheres retained RhB following 24 h immersion in a highly concentrated salt solution (1 M NaCl) and exhibited minimal RhB release (7.1%) under heating at 80 °C for 24 h. However, PEGDA@RhB-TA microspheres underwent rapid RhB release in a 50% v/v ethanol–water solution, liberating 73% of the encapsulated dye within 24 h. TA within the PEGDA@RhB-TA microsphere acts as a molecular lock by forming non-covalent interactions with RhB, significantly enhancing the stability of encapsulated RhB, and enabling the responsive release of RhB under specific conditions. Upon introduction into a microfluidic chip, PEGDA@RhB-TA microspheres enable the calculation of flow velocity through position tracking using high-speed camera imaging and fluorescence microscopy. These microspheres overcome the dual challenges of tracer stability and controlled release, making them suitable for fluid tracing and measuring flow rates. Full article
(This article belongs to the Collection Advances and Emerging Directions in Hydrogels)
Show Figures

Figure 1

15 pages, 5118 KB  
Article
Making Fluorescent Nylon, Polypropylene, and Polystyrene Microplastics for In Vivo and In Vitro Imaging
by Charles E. Bardawil, Jarrett Dobbins, Shannon Lankford, Saif Chowdrey, Jack Shumway, Gayathriy Balamayooran, Cedric Schaack and Rajeev Dhupar
Microplastics 2025, 4(4), 84; https://doi.org/10.3390/microplastics4040084 - 4 Nov 2025
Cited by 2 | Viewed by 2769
Abstract
Microplastics (MPs) are synthetic environmental pollutants increasingly linked to adverse human health effects. To study their biological impact, researchers require access to environmentally relevant MPs that can be accurately tracked in biological systems. However, most ambient MPs are composed of non-conjugated polymers that [...] Read more.
Microplastics (MPs) are synthetic environmental pollutants increasingly linked to adverse human health effects. To study their biological impact, researchers require access to environmentally relevant MPs that can be accurately tracked in biological systems. However, most ambient MPs are composed of non-conjugated polymers that lack intrinsic fluorescence, limiting their utility in live-cell or in vivo imaging. Addressing this challenge, we present two alternative labeling approaches that enable visualization, tracking, and quantification of MPs. First, we stained nylon and polypropylene MPs with Rhodamine 6G, a fluorescent dye known for its stability and compatibility with in vivo applications. These labeled MPs retained strong fluorescence in murine lung tissue for up to one week, as confirmed by fluorescent microscopy. Second, we conjugated aminated polystyrene microspheres with IRDye-800CW, a near-infrared fluorophore that enables high-resolution imaging with minimal tissue autofluorescence via an In Vivo Imaging System and confocal microscopy. In vivo experiments revealed organ-specific accumulation of IRDye-labeled MPs, with a 2.8-fold increase in the liver and a 5-fold increase in spleen compared to controls, detectable up to 72 h post-injection. These labeling strategies provide researchers with practical tools to visualize and study the biodistribution of MPs in biological systems, advancing efforts to understand their health implications. Full article
Show Figures

Graphical abstract

16 pages, 5756 KB  
Article
Performance Evaluation of Fluorescent Polymer Gel Microspheres as a Reservoir Conformance Control Agent
by Saya Shagymgereyeva, Bauyrzhan Sarsenbekuly, Wanli Kang and Sarsenbek Turtabayev
Gels 2025, 11(2), 85; https://doi.org/10.3390/gels11020085 - 22 Jan 2025
Cited by 8 | Viewed by 3994
Abstract
This study introduces fluorescent polymer gel microspheres (FPMs) as a novel approach to enhance conformance control in oil reservoirs. Designed to address the challenges of high-permeability zones, FPMs were synthesized via inverse suspension polymerization, incorporating 2-acrylamido-2-methylpropane sulfonic acid (AMPS) to improve thermal stability [...] Read more.
This study introduces fluorescent polymer gel microspheres (FPMs) as a novel approach to enhance conformance control in oil reservoirs. Designed to address the challenges of high-permeability zones, FPMs were synthesized via inverse suspension polymerization, incorporating 2-acrylamido-2-methylpropane sulfonic acid (AMPS) to improve thermal stability and swelling and fluorescein to enable fluorescence. Characterization using FT-IR, SEM, fluorescence spectroscopy, and thermal analysis revealed that FPMs swell significantly in brine, with diameters increasing from 46 μm to 210 μm, and maintain thermal stability up to 110 °C. These advanced properties make FPMs highly effective in reducing permeability and facilitating real-time tracking, offering a promising solution for improved oil recovery and efficient reservoir management. Full article
(This article belongs to the Special Issue Chemical and Gels for Oil Drilling and Enhanced Recovery)
Show Figures

Figure 1

17 pages, 5301 KB  
Article
Combined Dielectric-Optical Characterization of Single Cells Using Dielectrophoresis-Imaging Flow Cytometry
by Behnam Arzhang, Justyna Lee, Emerich Kovacs, Michael Butler, Elham Salimi, Douglas J. Thomson and Greg E. Bridges
Biosensors 2024, 14(12), 577; https://doi.org/10.3390/bios14120577 - 27 Nov 2024
Cited by 11 | Viewed by 3111
Abstract
In this paper, we present a microfluidic flow cytometer for simultaneous imaging and dielectric characterization of individual biological cells within a flow. Utilizing a combination of dielectrophoresis (DEP) and high-speed imaging, this system offers a dual-modality approach to analyze both cell morphology and [...] Read more.
In this paper, we present a microfluidic flow cytometer for simultaneous imaging and dielectric characterization of individual biological cells within a flow. Utilizing a combination of dielectrophoresis (DEP) and high-speed imaging, this system offers a dual-modality approach to analyze both cell morphology and dielectric properties, enhancing the ability to analyze, characterize, and discriminate cells in a heterogeneous population. A high-speed camera is used to capture images of and track multiple cells in real-time as they flow through a microfluidic channel. A wide channel is used, enabling analysis of many cells in parallel. A coplanar electrode array perpendicular to cell flow is incorporated at the bottom of the channel to perform dielectrophoresis-based dielectric characterization. A frequency-dependent voltage applied to the array produces a non-uniform electric field, translating cells to higher or lower velocity depending on their dielectric polarizability. In this paper, we demonstrate how cell size, obtained by optical imaging, and DEP response, obtained by particle tracking, can be used to discriminate viable and non-viable Chinese hamster ovary cells in a heterogeneous cell culture. Multiphysics electrostatic-fluid dynamics simulation is used to develop a relationship between cell incoming velocity, differential velocity, size, and the cell’s polarizability, which can subsequently be used to evaluate its physiological state. Measurement of a mixture of polystyrene microspheres is used to evaluate the accuracy of the cytometer. Full article
(This article belongs to the Special Issue Biosensing Applications for Cell Monitoring)
Show Figures

Figure 1

15 pages, 8445 KB  
Article
Improving the Signal-to-Noise Ratio of Axial Displacement Measurements of Microspheres Based on Compound Digital Holography Microscopy Combined with the Reconstruction Centering Method
by Yanan Zeng, Qihang Guo, Xiaodong Hu, Junsheng Lu, Xiaopan Fan, Haiyun Wu, Xiao Xu, Jun Xie and Rui Ma
Sensors 2024, 24(9), 2723; https://doi.org/10.3390/s24092723 - 24 Apr 2024
Cited by 1 | Viewed by 2505
Abstract
In 3D microsphere tracking, unlike in-plane motion that can be measured directly by a microscope, axial displacements are resolved by optical interference or a diffraction model. As a result, the axial results are affected by the environmental noise. The immunity to environmental noise [...] Read more.
In 3D microsphere tracking, unlike in-plane motion that can be measured directly by a microscope, axial displacements are resolved by optical interference or a diffraction model. As a result, the axial results are affected by the environmental noise. The immunity to environmental noise increases with measurement accuracy and the signal-to-noise ratio (SNR). In compound digital holography microscopy (CDHM)-based measurements, precise identification of the tracking marker is critical to ensuring measurement precision. The reconstruction centering method (RCM) was proposed to suppress the drawbacks caused by installation errors and, at the same time, improve the correct identification of the tracking marker. The reconstructed center is considered to be the center of the microsphere, rather than the center of imaging in conventional digital holographic microscopy. This method was verified by simulation of rays tracing through microspheres and axial moving experiments. The axial displacements of silica microspheres with diameters of 5 μm and 10 μm were tested by CDHM in combination with the RCM. As a result, the SNR of the proposed method was improved by around 30%. In addition, the method was successfully applied to axial displacement measurements of overlapped microspheres with a resolution of 2 nm. Full article
(This article belongs to the Special Issue Digital Holography in Optics: Techniques and Applications)
Show Figures

Figure 1

15 pages, 4826 KB  
Article
Preparation and Lubricating Properties of Polystyrene Composite Microspheres
by Wen Zeng, Weiqing Huang, Bing Guo, Yang Sun and Hangyan Shen
Materials 2023, 16(8), 3071; https://doi.org/10.3390/ma16083071 - 13 Apr 2023
Cited by 11 | Viewed by 3197
Abstract
In order to improve the lubrication performance of polystyrene microspheres (PS) as solid lubricant in drilling fluids, elastic graphite–polystyrene composite microspheres (EGR/PS), montmorillonite–elastic graphite–polystyrene composite microspheres (OMMT/EGR/PS), and polytetrafluoroethylene–polystyrene composite microspheres (PTFE/PS) were prepared by suspension polymerization. OMMT/EGR/PS has a rough surface, while [...] Read more.
In order to improve the lubrication performance of polystyrene microspheres (PS) as solid lubricant in drilling fluids, elastic graphite–polystyrene composite microspheres (EGR/PS), montmorillonite–elastic graphite–polystyrene composite microspheres (OMMT/EGR/PS), and polytetrafluoroethylene–polystyrene composite microspheres (PTFE/PS) were prepared by suspension polymerization. OMMT/EGR/PS has a rough surface, while the surfaces of the other three composite microspheres are smooth. Among the four kinds of composite microspheres, the largest particle is OMMT/EGR/PS, and the average size is about 400 μm. The smallest particle is PTFE/PS, and the average size is about 49 μm. Compared with pure water, the friction coefficient of PS, EGR/PS, OMMT/EGR/PS and PTFE/PS reduced by 25%, 28%, 48%, and 62%, respectively. The wear tracks of EGR/PS, OMMT/EGR/PS and PTFE/PS are narrower and smoother than those of pure water. When the content of PTFE is 4.0 wt%, the friction coefficient and wear volume of PTFE/PS are 0.213 and 2.45 × 10−4 mm3—74% and 92.4% lower than that of pure water, respectively. Full article
Show Figures

Figure 1

21 pages, 5049 KB  
Article
Enhancing the Antioxidant, Antibacterial, and Wound Healing Effects of Melaleuca alternifolia Oil by Microencapsulating It in Chitosan-Sodium Alginate Microspheres
by Anbazhagan Sathiyaseelan, Xin Zhang and Myeong-Hyeon Wang
Nutrients 2023, 15(6), 1319; https://doi.org/10.3390/nu15061319 - 7 Mar 2023
Cited by 40 | Viewed by 4996
Abstract
In this study, antibacterial and antioxidant molecules-rich Melaleuca alternifolia oil (tea tree oil (TTO)) loaded chitosan (CS) based nanoemulsions (NEMs) were prepared and encapsulated by sodium alginate (SA) microsphere for antibacterial wound dressing. CS-TTO NEMs were prepared by oil-in-water emulsion technique, and the [...] Read more.
In this study, antibacterial and antioxidant molecules-rich Melaleuca alternifolia oil (tea tree oil (TTO)) loaded chitosan (CS) based nanoemulsions (NEMs) were prepared and encapsulated by sodium alginate (SA) microsphere for antibacterial wound dressing. CS-TTO NEMs were prepared by oil-in-water emulsion technique, and the nanoparticle tracking analysis (NTA) confirmed that the CS-TTO NEMs had an average particle size of 89.5 nm. Further, the SA-CS-TTO microsphere was confirmed through SEM analysis with an average particle size of 0.76 ± 0.10 µm. The existence of TTO in CS NEMs and SA encapsulation was evidenced through FTIR analysis. The XRD spectrum proved the load of TTO and SA encapsulation with CS significantly decreased the crystalline properties of the CS-TTO and SA-CS-TTO microsphere. The stability of TTO was increased by the copolymer complex, as confirmed through thermal gravimetric analysis (TGA). Furthermore, TTO was released from the CS–SA complex in a sustained manner and significantly inhibited the bacterial pathogens observed under confocal laser scanning microscopy (CLSM). In addition, CS-TTO (100 µg/mL) showed antioxidant potential (>80%), thereby increasing the DPPH and ABTS free radicals scavenging ability of SA-CS-TTO microspheres. Moreover, CS and SA-CS-TTO microsphere exhibited negligible cytotoxicity and augmented the NIH3T3 cell proliferation confirmed in the in vitro scratch assay. This study concluded that the SA-CS-TTO microsphere could be an antibacterial and antioxidant wound dressing. Full article
Show Figures

Figure 1

18 pages, 2537 KB  
Article
Cultivation and Imaging of S. latissima Embryo Monolayered Cell Sheets Inside Microfluidic Devices
by Thomas Clerc, Samuel Boscq, Rafaele Attia, Gabriele S. Kaminski Schierle, Bénédicte Charrier and Nino F. Läubli
Bioengineering 2022, 9(11), 718; https://doi.org/10.3390/bioengineering9110718 - 21 Nov 2022
Cited by 4 | Viewed by 4020
Abstract
The culturing and investigation of individual marine specimens in lab environments is crucial to further our understanding of this highly complex ecosystem. However, the obtained results and their relevance are often limited by a lack of suitable experimental setups enabling controlled specimen growth [...] Read more.
The culturing and investigation of individual marine specimens in lab environments is crucial to further our understanding of this highly complex ecosystem. However, the obtained results and their relevance are often limited by a lack of suitable experimental setups enabling controlled specimen growth in a natural environment while allowing for precise monitoring and in-depth observations. In this work, we explore the viability of a microfluidic device for the investigation of the growth of the alga Saccharina latissima to enable high-resolution imaging by confining the samples, which usually grow in 3D, to a single 2D plane. We evaluate the specimen’s health based on various factors such as its growth rate, cell shape, and major developmental steps with regard to the device’s operating parameters and flow conditions before demonstrating its compatibility with state-of-the-art microscopy imaging technologies such as the skeletonisation of the specimen through calcofluor white-based vital staining of its cell contours as well as the immunolocalisation of the specimen’s cell wall. Furthermore, by making use of the on-chip characterisation capabilities, we investigate the influence of altered environmental illuminations on the embryonic development using blue and red light. Finally, live tracking of fluorescent microspheres deposited on the surface of the embryo permits the quantitative characterisation of growth at various locations of the organism. Full article
(This article belongs to the Special Issue Microfluidics and Miniaturized Systems in Bioengineering)
Show Figures

Graphical abstract

8 pages, 2957 KB  
Communication
Experimental and Numerical Validation of Whispering Gallery Resonators as Optical Temperature Sensors
by Franzette Paz-Buclatin, Ylenia Perera-Suárez, Inocencio R. Martín, Susana Ríos, Omar de Varona, Airán Ródenas and Leopoldo L. Martin
Sensors 2022, 22(20), 7831; https://doi.org/10.3390/s22207831 - 15 Oct 2022
Cited by 4 | Viewed by 2590
Abstract
This study experimentally and numerically validates the commonly employed technique of laser-induced heating of a material in optical temperature sensing studies. Furthermore, the Er3+-doped glass microspheres studied in this work can be employed as remote optical temperature sensors. Laser-induced self-heating is a useful [...] Read more.
This study experimentally and numerically validates the commonly employed technique of laser-induced heating of a material in optical temperature sensing studies. Furthermore, the Er3+-doped glass microspheres studied in this work can be employed as remote optical temperature sensors. Laser-induced self-heating is a useful technique commonly employed in optical temperature sensing research when two temperature-dependent parameters can be correlated, such as in fluorescence intensity ratio vs. interferometric calibration, allowing straightforward sensor characterization. A frequent assumption in such experiments is that thermal homogeneity within the sensor volume, that is, a sound hypothesis when dealing with small volume to surface area ratio devices such as microresonators, but has never been validated. In order to address this issue, we performed a series of experiments and simulations on a microsphere supporting whispering gallery mode resonances, laser heating it at ambient pressure and medium vacuum while tracking the resonance wavelength shift and comparing it to the shift rate observed in a thermal bath. The simulations were done starting only from the material properties of the bulk glass to simulate the physical phenomena of laser heating and resonance of the microsphere glass. Despite the simplicity of the model, both measurements and simulations are in good agreement with a highly homogeneous temperature within the resonator, thus validating the laser heating technique. Full article
(This article belongs to the Special Issue Temperature Sensors 2021-2023)
Show Figures

Figure 1

15 pages, 2164 KB  
Article
YOLO Algorithm for Long-Term Tracking and Detection of Escherichia Coli at Different Depths of Microchannels Based on Microsphere Positioning Assistance
by Lesheng Sun, Ying Xu, Zhikang Rao, Juntao Chen, Zhe Liu and Ning Lu
Sensors 2022, 22(19), 7454; https://doi.org/10.3390/s22197454 - 30 Sep 2022
Cited by 19 | Viewed by 3980
Abstract
The effect evaluation of the antibiotic susceptibility test based on bacterial solution is of great significance for clinical diagnosis and prevention of antibiotic abuse. Applying a microfluidic chip as the detection platform, the detection method of using microscopic images to observe bacteria under [...] Read more.
The effect evaluation of the antibiotic susceptibility test based on bacterial solution is of great significance for clinical diagnosis and prevention of antibiotic abuse. Applying a microfluidic chip as the detection platform, the detection method of using microscopic images to observe bacteria under antibiotic can greatly speed up the detection time, which is more suitable for high-throughput detection. However, due to the influence of the depth of the microchannel, there are multiple layers of bacteria under the focal depth of the microscope, which greatly affects the counting and recognition accuracy and increases the difficulty of relocation of the target bacteria, as well as extracting the characteristics of bacterial liquid changes under the action of antibiotics. After the focal depth of the target bacteria is determined, although the z-axis can be controlled with the help of a three-dimensional micro-operator, the equipment is difficult to operate and the long-term changes of the target bacteria cannot be tracked quickly and accurately. In this paper, the YOLOv5 algorithm is adopted to accurately identify bacteria with different focusing states of multi-layer bacteria at the z-axis with any focal depth. In the meantime, a certain amount of microspheres were mixed into bacteria to assist in locating bacteria, which was convenient for tracking the growth state of bacteria over a long period, and the recognition rates of both bacteria and microspheres were high. The recognition accuracy and counting accuracy of bacteria are 0.734 and 0.714, and the two recognition rates of microspheres are 0.910 and 0.927, respectively, which are much higher than the counting accuracy of 0.142 for bacteria and 0.781 for microspheres with the method of enhanced depth of field (EDF method). Moreover, during long-term bacterial tracking and detection, target bacteria at multiple z-axis focal depth positions can be recorded by the aid of microspheres as a positioning aid for 3D reconstruction, and the focal depth positions can be repositioned within 3–10 h. The structural similarity (SSIM) of microscopic image structure differences at the same focal depth fluctuates between 0.960 and 0.975 at different times, and the root-mean-square error (RMSE) fluctuates between 8 and 12, which indicates that the method also has good relocation accuracy. Thus, this method provides the basis for rapid, high-throughput, and long-term analysis of microscopic changes (e.g., morphology, size) of bacteria detection under the addition of antibiotics with different concentrations based on microfluidic channels in the future. Full article
(This article belongs to the Section Physical Sensors)
Show Figures

Figure 1

23 pages, 10515 KB  
Article
Visualization of Interstitial Pore Fluid Flow
by Linzhu Li and Magued Iskander
J. Imaging 2022, 8(2), 32; https://doi.org/10.3390/jimaging8020032 - 30 Jan 2022
Cited by 15 | Viewed by 5723
Abstract
Pore scale analysis of flow through porous media is of interest because it is essential for understanding internal erosion and piping, among other applications. Past studies have mainly focused on exploring macroscopic flow to infer microscopic phenomena. An innovative method is introduced in [...] Read more.
Pore scale analysis of flow through porous media is of interest because it is essential for understanding internal erosion and piping, among other applications. Past studies have mainly focused on exploring macroscopic flow to infer microscopic phenomena. An innovative method is introduced in this study which permits visualization of interstitial fluid flow through the pores of a saturated synthetic transparent granular medium at the microscale. Several representative images of Ottawa sand were obtained using dynamic image analysis (DIA), for comparison with flow through perfect cylinders. Magnified transparent soil particles made of hydrogel were cast in 3D printed molds. Custom 3D printed jigs were employed for accurate positioning of the particles to ensure that particles have the same flow area within the soil. The pore fluid was embedded with silver-coated hollow microspheres that allowed for their florescence and tracking their movement within the model when illuminated by a laser light source. Images of the flow were captured from the model using a high-speed camera. This, along with particle image velocimetry (PIV) provided for the velocity and direction analysis of fluid flow movements within the pore space of a planar 2D model. Comparison of interstitial flow through homogeneous porosity-controlled Ottawa-shaped and cylindrical particles demonstrates that the magnitude of turbulence is related to particle roundness. Full article
(This article belongs to the Special Issue Recent Advances in Image-Based Geotechnics)
Show Figures

Figure 1

9 pages, 1623 KB  
Article
Positioning Accuracy in Holographic Optical Traps
by Frederic Català-Castro and Estela Martín-Badosa
Micromachines 2021, 12(5), 559; https://doi.org/10.3390/mi12050559 - 15 May 2021
Cited by 4 | Viewed by 3798
Abstract
Spatial light modulators (SLMs) have been widely used to achieve dynamic control of optical traps. Often, holographic optical tweezers have been presumed to provide nanometer or sub-nanometer positioning accuracy. It is known that some features concerning the digitalized structure of SLMs cause a [...] Read more.
Spatial light modulators (SLMs) have been widely used to achieve dynamic control of optical traps. Often, holographic optical tweezers have been presumed to provide nanometer or sub-nanometer positioning accuracy. It is known that some features concerning the digitalized structure of SLMs cause a loss in steering efficiency of the optical trap, but their effect on trap positioning accuracy has been scarcely analyzed. On the one hand, the SLM look-up-table, which we found to depend on laser power, produces positioning deviations when the trap is moved at the micron scale. On the other hand, phase quantization, which makes linear phase gratings become phase staircase profiles, leads to unexpected local errors in the steering angle. We have tracked optically trapped microspheres with sub-nanometer accuracy to study the effects on trap positioning, which can be as high as 2 nm in certain cases. We have also implemented a correction strategy that enabled the reduction of errors down to 0.3 nm. Full article
(This article belongs to the Special Issue Optical Trapping of Micro/Nanoparticles)
Show Figures

Figure 1

11 pages, 2211 KB  
Article
Alteration of 3D Matrix Stiffness Regulates Viscoelasticity of Human Mesenchymal Stem Cells
by Ting-Wei Kao, Arthur Chiou, Keng-Hui Lin, Yi-Shiuan Liu and Oscar Kuang-Sheng Lee
Int. J. Mol. Sci. 2021, 22(5), 2441; https://doi.org/10.3390/ijms22052441 - 28 Feb 2021
Cited by 8 | Viewed by 3975
Abstract
Human mesenchymal stem cells (hMSCs) possess potential of bone formation and were proposed as ideal material against osteoporosis. Although interrogation of directing effect on lineage specification by physical cues has been proposed, how mechanical stimulation impacts intracellular viscoelasticity during osteogenesis remained enigmatic. Cyto-friendly [...] Read more.
Human mesenchymal stem cells (hMSCs) possess potential of bone formation and were proposed as ideal material against osteoporosis. Although interrogation of directing effect on lineage specification by physical cues has been proposed, how mechanical stimulation impacts intracellular viscoelasticity during osteogenesis remained enigmatic. Cyto-friendly 3D matrix was prepared with polyacrylamide and conjugated fibronectin. The hMSCs were injected with fluorescent beads and chemically-induced toward osteogenesis. The mechanical properties were assessed using video particle tracking microrheology. Inverted epifluorescence microscope was exploited to capture the Brownian trajectory of hMSCs. Mean square displacement was calculated and transformed into intracellular viscoelasticity. Two different stiffness of microspheres (12 kPa, 1 kPa) were established. A total of 45 cells were assessed. hMSCs possessed equivalent mechanical traits initially in the first week, while cells cultured in rigid matrix displayed significant elevation over elastic (G′) and viscous moduli (G″) on day 7 (p < 0.01) and 14 (p < 0.01). However, after two weeks, soft niches no longer stiffened hMSCs, whereas the effect by rigid substrates was consistently during the entire differentiation course. Stiffness of matrix impacted the viscoelasticity of hMSCs. Detailed recognition of how microenvironment impacts mechanical properties and differentiation of hMSCs will facilitate the advancement of tissue engineering and regenerative medicine. Full article
(This article belongs to the Special Issue Mesenchymal Stem Cells in Health and Disease)
Show Figures

Figure 1

Back to TopTop