Sign in to use this feature.

Years

Between: -

Subjects

remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline

Journals

Article Types

Countries / Regions

remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline

Search Results (130)

Search Parameters:
Keywords = low-voltage (LV) network

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
22 pages, 2738 KiB  
Article
Mitigation of Solar PV Impact in Four-Wire LV Radial Distribution Feeders Through Reactive Power Management Using STATCOMs
by Obaidur Rahman, Duane Robinson and Sean Elphick
Electronics 2025, 14(15), 3063; https://doi.org/10.3390/electronics14153063 - 31 Jul 2025
Viewed by 184
Abstract
Australia has the highest per capita penetration of rooftop solar PV systems in the world. Integration of these systems has led to reverse power flow and associated voltage rise problems in residential low-voltage (LV) distribution networks. Furthermore, random, uncontrolled connection of single-phase solar [...] Read more.
Australia has the highest per capita penetration of rooftop solar PV systems in the world. Integration of these systems has led to reverse power flow and associated voltage rise problems in residential low-voltage (LV) distribution networks. Furthermore, random, uncontrolled connection of single-phase solar systems can exacerbate voltage unbalance in these networks. This paper investigates the application of a Static Synchronous Compensator (STATCOM) for the improvement of voltage regulation in four-wire LV distribution feeders through reactive power management as a means of mitigating voltage regulation and unbalance challenges. To demonstrate the performance of the STATCOM with varying loads and PV output, a Q-V droop curve is applied to specify the level of reactive power injection/absorption required to maintain appropriate voltage regulation. A practical four-wire feeder from New South Wales, Australia, has been used as a case study network to analyse improvements in system performance through the use of the STATCOM. The outcomes indicate that the STATCOM has a high degree of efficacy in mitigating voltage regulation and unbalance excursions. In addition, compared to other solutions identified in the existing literature, the STATCOM-based solution requires no sophisticated communication infrastructure. Full article
(This article belongs to the Special Issue Power Electronics and Renewable Energy System)
Show Figures

Figure 1

23 pages, 1420 KiB  
Article
Utilising Smart-Meter Harmonic Data for Low-Voltage Network Topology Identification
by Ali Othman, Neville R. Watson, Andrew Lapthorn and Radnya Mukhedkar
Energies 2025, 18(13), 3333; https://doi.org/10.3390/en18133333 - 25 Jun 2025
Viewed by 358
Abstract
Identifying the topology of low-voltage (LV) networks is becoming increasingly important. Having precise and accurate topology information is crucial for future network operations and network modelling. Topology identification approaches based on smart-meter data typically rely on Root Mean Square (RMS) voltage, current, and [...] Read more.
Identifying the topology of low-voltage (LV) networks is becoming increasingly important. Having precise and accurate topology information is crucial for future network operations and network modelling. Topology identification approaches based on smart-meter data typically rely on Root Mean Square (RMS) voltage, current, and power measurements, which are limited in accuracy due to factors such as time resolution, measurement intervals, and instrument errors. This paper presents a novel methodology for identifying distribution network topologies through the utilisation of smart-meter harmonic data. The methodology introduces, for the first time, the application of voltage Total Harmonic Distortion (THD) and individual harmonic components (V2V20) as topology identifiers. The proposed approach leverages the unique properties of harmonic distortion to improve the accuracy of topology identification. This paper first analyses the influential factors affecting topology identification, establishing that harmonic distortion propagation patterns offer superior discrimination compared to RMS voltage. Through systematic investigation, the findings demonstrate the potential of harmonic-based analysis as a more effective alternative for topology identification in modern power distribution systems. Full article
Show Figures

Figure 1

32 pages, 5733 KiB  
Article
Towards Sustainable Electricity for All: Techno-Economic Analysis of Conventional Low-Voltage-to-Microgrid Conversion
by Frimpong Kyeremeh, Dennis Acheampong, Zhi Fang, Feng Liu and Forson Peprah
Sustainability 2025, 17(11), 5178; https://doi.org/10.3390/su17115178 - 4 Jun 2025
Viewed by 441
Abstract
Ghana’s electricity grid remains heavily fossil-fuel dependent (69%), resulting in high costs and unstable low-voltage (LV) networks, exacerbating supply shortages. This study evaluates the technical and economic feasibility of converting the Obaa-Yaa LV substation in Drobo, Ghana, into a solar-powered microgrid. Using the [...] Read more.
Ghana’s electricity grid remains heavily fossil-fuel dependent (69%), resulting in high costs and unstable low-voltage (LV) networks, exacerbating supply shortages. This study evaluates the technical and economic feasibility of converting the Obaa-Yaa LV substation in Drobo, Ghana, into a solar-powered microgrid. Using the forward–backward method for technical analysis and financial metrics (NPV, IRR, DPP, and PI), the results show that rooftop solar on seven households generates 676,742 kWh annually—exceeding local demand by 115.8 kW—with no voltage violations (240 V ± 6%) and minimal losses (9.24 kW). Economic viability is demonstrated via an NPV of GHS 2.1M, IRR of 17%, and a 10-year payback. The findings underscore solar microgrids as a pragmatic solution for Ghana’s energy challenges, urging policymakers to incentivize decentralized renewable systems. Full article
(This article belongs to the Special Issue Renewable Energy Conversion and Sustainable Power Systems Engineering)
Show Figures

Figure 1

33 pages, 1827 KiB  
Review
Advances in Hosting Capacity Assessment and Enhancement Techniques for Distributed Energy Resources: A Review of Dynamic Operating Envelopes in the Australian Grid
by Naveed Ali Brohi, Gokul Thirunavukkarasu, Mehdi Seyedmahmoudian, Kafeel Ahmed, Alex Stojcevski and Saad Mekhilef
Energies 2025, 18(11), 2922; https://doi.org/10.3390/en18112922 - 2 Jun 2025
Viewed by 763
Abstract
The increasing penetration of distributed energy resources (DERs) such as solar photovoltaic (PV) systems, battery energy storage systems (BESSs), and electric vehicles (EVs) in low-voltage (LV) and medium-voltage (MV) distribution networks is reshaping traditional grid operations. This shift introduces challenges including voltage violations, [...] Read more.
The increasing penetration of distributed energy resources (DERs) such as solar photovoltaic (PV) systems, battery energy storage systems (BESSs), and electric vehicles (EVs) in low-voltage (LV) and medium-voltage (MV) distribution networks is reshaping traditional grid operations. This shift introduces challenges including voltage violations, thermal overloading, and power quality issues due to bidirectional power flows. Hosting capacity (HC) assessment has become essential for quantifying and optimizing DER integration while ensuring grid stability. This paper reviews state-of-the-art HC assessment methods, including deterministic, stochastic, time-series, and AI-based approaches. Techniques for enhancing HC—such as on-load tap changers, reactive power control, and network reconfiguration—are also discussed. A key focus is the emerging concept of dynamic operating envelopes (DOEs), which enable real-time allocation of HC by dynamically adjusting import/export limits for DERs based on operational conditions. The paper examines the benefits, challenges, and implementation of DOEs, supported by insights from Australian projects. Technical, regulatory, and social aspects are addressed, including network visibility, DER uncertainty, scalability, and cybersecurity. The study highlights the potential of integrating DOEs with other HC enhancement strategies to support efficient, reliable, and scalable DER integration in modern distribution networks. Full article
(This article belongs to the Special Issue Emerging Trends and Challenges in Zero-Energy Districts)
Show Figures

Figure 1

16 pages, 4413 KiB  
Article
Autonomous Control of Electric Vehicles Using Voltage Droop
by Hanchi Zhang, Rakesh Sinha, Hessam Golmohamadi, Sanjay K. Chaudhary and Birgitte Bak-Jensen
Energies 2025, 18(11), 2824; https://doi.org/10.3390/en18112824 - 29 May 2025
Viewed by 377
Abstract
The surge in electric vehicles (EVs) in Denmark challenges the country’s residential low-voltage (LV) distribution system. In particular, it increases the demand for home EV charging significantly and possibly overloads the LV grid. This study analyzes the impact of EV charging integration on [...] Read more.
The surge in electric vehicles (EVs) in Denmark challenges the country’s residential low-voltage (LV) distribution system. In particular, it increases the demand for home EV charging significantly and possibly overloads the LV grid. This study analyzes the impact of EV charging integration on Denmark’s residential distribution networks. A residential grid comprising 67 households powered by a 630 kVA transformer is studied using DiGSILENT PowerFactory. With the assumption of simultaneous charging of all EVs, the transformer can be heavily loaded up to 147.2%. Thus, a voltage-droop based autonomous control approach is adopted, where the EV charging power is dynamically adjusted based on the point-of-connection voltage of each charger instead of the fixed rated power. This strategy eliminates overloading of the transformers and cables, ensuring they operate within a pre-set limit of 80%. Voltage drops are mitigated within the acceptable safety range of ±10% from normal voltage. These results highlight the effectiveness of the droop control strategy in managing EV charging power. Finally, it exemplifies the benefits of intelligent EV charging systems in Horizon 2020 EU Projects like SERENE and SUSTENANCE. The findings underscore the necessity to integrate smart control mechanisms, consider reinforcing grids, and promote active consumer participation to meet the rising demand for a low-carbon future. Full article
Show Figures

Figure 1

19 pages, 3253 KiB  
Article
Research on the Modelling and Analysis of the Penetration of Renewable Sources and Storage into Electrical Networks
by Eva Simonič, Sebastijan Seme and Klemen Sredenšek
Energies 2025, 18(9), 2263; https://doi.org/10.3390/en18092263 - 29 Apr 2025
Viewed by 418
Abstract
To address the growing integration of renewable energy sources and storage systems into distribution networks, there is a need for effective tools that can assess the impact of these technologies on grid performance. This paper investigates the impact of integrating residential rooftop photovoltaic [...] Read more.
To address the growing integration of renewable energy sources and storage systems into distribution networks, there is a need for effective tools that can assess the impact of these technologies on grid performance. This paper investigates the impact of integrating residential rooftop photovoltaic (PV) systems and battery energy storage systems (BESSs) into low-voltage (LV) distribution networks. A stochastic approach, using the Monte Carlo method, is applied to randomly place PV systems across the network, generating multiple scenarios for power flow simulations in MATLAB Simulink R2024b. The method incorporates real-world consumer load data and grid topology, representing a novel approach in simulating distribution network behaviour accurately. The novelty of this paper lies in its ability to combine stochastic PV placement with real-world load data, providing a more realistic representation of network conditions. The simulation results revealed that widespread PV deployment can lead to overvoltage issues, but the integration of BESSs alongside PV systems mitigates these problems significantly. The findings of this paper offer valuable insights for Distribution Network Operators, aiding in the development of strategies for optimal PV and BESS integration to enhance grid performance. Full article
Show Figures

Figure 1

18 pages, 12587 KiB  
Article
Indirect Electrostatic Discharge (ESD) Effects on Shielded Components Installed in MV/LV Substations
by Giuseppe Attolini, Salvatore Celozzi and Erika Stracqualursi
Energies 2025, 18(5), 1056; https://doi.org/10.3390/en18051056 - 21 Feb 2025
Viewed by 552
Abstract
Standards describing the test procedures recommended to investigate the shielding effectiveness of enclosures have two major issues: they generally prescribe the assessment of the electromagnetic field of empty cavities, and they do not deal with very small enclosures. However, the dimensions of some [...] Read more.
Standards describing the test procedures recommended to investigate the shielding effectiveness of enclosures have two major issues: they generally prescribe the assessment of the electromagnetic field of empty cavities, and they do not deal with very small enclosures. However, the dimensions of some very common shielded apparatus are smaller than those considered in the standards and the electromagnetic field distribution inside the shielded structure is strongly affected by the enclosure content. In this paper, both issues have been investigated for two components commonly used in medium voltage/low voltage (MV/LV) substations: a mini personal computer used to store, process, and transmit relevant data on the status of the electric network, with these aspects being essential in smart grids, and an electronic relay which is ubiquitous in MV/LV substations. Both components are partially contained in a metallic enclosure which provides a certain amount of electromagnetic shielding against external interferences. It is observed that an electrostatic discharge may cause a failure and/or a loss of data, requiring an improvement of shielding characteristics or a wise choice of the positions where the most sensitive devices are installed inside the enclosure. Since the dimensions of very small enclosures, fully occupied by their internal components, do not allow for the insertion of sensors inside the protected volume, numerical analysis is considered as the only way for the appraisal of the effects induced by a typical source of interference, such as an electrostatic discharge. Full article
(This article belongs to the Section F3: Power Electronics)
Show Figures

Figure 1

20 pages, 6342 KiB  
Article
Low-Voltage Renewable Energy Communities’ Impact on the Distribution Networks
by Susanna Mocci, Simona Ruggeri and Fabrizio Pilo
Energies 2025, 18(1), 126; https://doi.org/10.3390/en18010126 - 31 Dec 2024
Cited by 3 | Viewed by 1298
Abstract
Renewable energy communities (RECs) are widely regarded as a transformative opportunity to enhance the management of electricity distribution networks, benefiting the system as a whole and its participants through local energy production, increased self-consumption, and empowering citizens. However, their proliferation introduces significant challenges [...] Read more.
Renewable energy communities (RECs) are widely regarded as a transformative opportunity to enhance the management of electricity distribution networks, benefiting the system as a whole and its participants through local energy production, increased self-consumption, and empowering citizens. However, their proliferation introduces significant challenges for distribution system management, particularly at the low-voltage (LV) level, where participants are primarily located. Despite its critical role, the LV network is often overlooked in favor of studies focusing on the system-level impacts. This paper addresses this gap by evaluating the impact of RECs on LV networks and the broader distribution system. The study analyzes various LV networks representative of the Italian context, encompassing both rural and urban areas. By leveraging the software tool OpenDSS and Monte Carlo simulations over an entire year, the analysis captures the inherent variability of load demand and photovoltaic generation, as well as the resulting network imbalances under diverse policy scenarios. The findings reveal that the increasing level of self-consumption could significantly challenge distribution network operation, limiting also the sourcing of flexibility. These results underscore the necessity for advanced management strategies and targeted investments in grid flexibility to ensure the reliability and efficiency of distribution networks integrating RECs. Full article
(This article belongs to the Special Issue Application of Machine Learning Tools for Energy System)
Show Figures

Figure 1

31 pages, 10502 KiB  
Article
Flexible Simulation Platform for Generating Realistic Waveforms with Voltage Notches
by Joaquín E. Caicedo, Olga Zyabkina, Edwin Rivas and Jan Meyer
Appl. Sci. 2024, 14(23), 11031; https://doi.org/10.3390/app142311031 - 27 Nov 2024
Viewed by 866
Abstract
Voltage notches are steady-state sub-cycle waveform distortions caused by the normal operation of line-commutated power converters, significantly impacting power quality in industrial low-voltage (LV) networks. Despite their common occurrence, research on this phenomenon is still incipient, and realistic simulation platforms are lacking. This [...] Read more.
Voltage notches are steady-state sub-cycle waveform distortions caused by the normal operation of line-commutated power converters, significantly impacting power quality in industrial low-voltage (LV) networks. Despite their common occurrence, research on this phenomenon is still incipient, and realistic simulation platforms are lacking. This paper introduces a detailed MATLAB (R2024a)/Simulink-based simulation platform that models a benchmark low-voltage industrial installation, including a six-pulse controlled rectifier, linear loads, and a capacitor bank for power factor correction. Systematic simulations are performed with the platform to examine the sensitivity of notch characteristics to key parameters within plausible ranges, such as short-circuit power at the point of common coupling, commutation reactance, firing angle, snubber circuits, and rated power of the rectifier. In addition, parameters such as the rated power of linear loads and the compensation power of the capacitor bank are examined. Other influencing parameters including background voltage unbalance and distortion are also modeled and considered. A comparative analysis with field measurements from German industrial LV networks validates the plausibility and suitability of the simulations. Building upon this platform, a Monte Carlo simulation approach is adopted to generate extensive datasets of realistic voltage notch waveforms by randomly varying these key parameters. A case study conducted under conditions typical of German LV networks demonstrates the applicability of the simulations. To support further research, the simulation platform and exemplary synthetic waveforms are provided alongside the paper, serving as a valuable tool for testing and designing strategies for analysis, detection, and monitoring of voltage notches. Full article
(This article belongs to the Special Issue Analysis, Modelling and Simulation in Electrical Power Systems)
Show Figures

Figure 1

25 pages, 7500 KiB  
Article
An ANN-Based Method for On-Load Tap Changer Control in LV Networks with a Large Share of Photovoltaics—Comparative Analysis
by Klara Janiga, Piotr Miller, Robert Małkowski and Michał Izdebski
Energies 2024, 17(22), 5749; https://doi.org/10.3390/en17225749 - 17 Nov 2024
Cited by 3 | Viewed by 1482
Abstract
The paper proposes a new local method of controlling the on-load tap changer (OLTC) of a transformer to mitigate negative voltage phenomena in low-voltage (LV) networks with a high penetration of photovoltaic (PV) installations. The essence of the method is the use of [...] Read more.
The paper proposes a new local method of controlling the on-load tap changer (OLTC) of a transformer to mitigate negative voltage phenomena in low-voltage (LV) networks with a high penetration of photovoltaic (PV) installations. The essence of the method is the use of the load compensation (LC) function with settings determined via artificial neural network (ANN) algorithms. The proposed method was compared with other selected local methods recommended in European regulations, in particular with those currently required by Polish distribution system operators (DSOs). Comparative studies were performed using the model of the 116-bus IEEE test network, taking into account the unbalance in the network and the voltage variation on the medium voltage (MV) side. Full article
(This article belongs to the Collection Artificial Intelligence and Smart Energy)
Show Figures

Figure 1

20 pages, 5342 KiB  
Article
Optimal EV Charging and PV Siting in Prosumers towards Loss Reduction and Voltage Profile Improvement in Distribution Networks
by Christina V. Grammenou, Magdalini Dragatsika and Aggelos S. Bouhouras
World Electr. Veh. J. 2024, 15(10), 462; https://doi.org/10.3390/wevj15100462 - 11 Oct 2024
Cited by 1 | Viewed by 1450
Abstract
In this paper, the problem of simultaneous charging of Electrical Vehicles (EVs) in distribution networks (DNs) is examined in order to depict congestion issues, increased power losses, and voltage constraint violations. To this end, this paper proposes an optimal EV charging schedule in [...] Read more.
In this paper, the problem of simultaneous charging of Electrical Vehicles (EVs) in distribution networks (DNs) is examined in order to depict congestion issues, increased power losses, and voltage constraint violations. To this end, this paper proposes an optimal EV charging schedule in order to allocate the charging of EVs in non-overlapping time slots, aiming to avoid overloading conditions that could stress the DN operation. The problem is structured as a linear optimization problem in GAMS, and the linear Distflow is utilized for the power flow analysis required. The proposed approach is compared to the one where EV charging is not optimally scheduled and each EV is expected to start charging upon its arrival at the residential charging spot. Moreover, the analysis is extended to examine the optimal siting of small-sized residential Photovoltaic (PV) systems in order to provide further relief to the DN. A mixed-integer quadratic optimization model was formed to integrate the PV siting into the optimization problem as an additional optimization variable and is compared to a heuristic-based approach for determining the sites for PV installation. The proposed methodology has been applied in a typical low-voltage (LV) DN as a case study, including real power demand data for the residences and technical characteristics for the EVs. The results indicate that both the DN power losses and the voltage profile are further improved in regard to the heuristic-based approach, and the simultaneously scheduled penetration of EVs and PVs could yield up to a 66.3% power loss reduction. Full article
(This article belongs to the Special Issue Data Exchange between Vehicle and Power System for Optimal Charging)
Show Figures

Figure 1

19 pages, 775 KiB  
Review
Asymmetric Operation of Power Networks, State of the Art, Challenges, and Opportunities
by Ansar Berdygozhin and David Campos-Gaona
Energies 2024, 17(20), 5021; https://doi.org/10.3390/en17205021 - 10 Oct 2024
Cited by 2 | Viewed by 1189
Abstract
The asymmetric operation is a method that allows High and Extra-High Voltage (HV, EHV) power lines to function with one or two phases open. With the increasing share of Renewable Energy Sources (RES) in National Power Systems (NPS), they are becoming more volatile [...] Read more.
The asymmetric operation is a method that allows High and Extra-High Voltage (HV, EHV) power lines to function with one or two phases open. With the increasing share of Renewable Energy Sources (RES) in National Power Systems (NPS), they are becoming more volatile and less reliable due to decreasing inertia and other issues related to the integration and exploitation of the Inverter-Based Resources (IBR) (decreasing short-circuit ratio, different types of interactions, etc.). On the other hand, phase-to-ground faults are a common cause of tripping off power lines which affects the overall reliability of the power system. Thus, for power systems experiencing a decreasing trend in reliability and robustness, the asymmetrical operation of the power lines may enhance them. In this way, this article reviews the state of the art and new developments in the academic landscape regarding asymmetrical operation. The review is not, however, limited to HV and EHV systems, so it examines cases of asymmetric operation in Low and Medium Voltages (LV, MV) as well. The challenges and opportunities that this unique mode of operation imposes on power networks are also presented, providing a fresh reference for researchers looking to enter this topic. Full article
(This article belongs to the Special Issue Energy, Electrical and Power Engineering 2024)
Show Figures

Figure 1

18 pages, 4644 KiB  
Article
Optimization Strategy for an Outage Sequence in Medium- and Low-Voltage Distribution Networks Considering the Importance of Users
by Wei Li, Jingzhe Wang, Hao Bai, Yongqian Yan, Min Xu, Yipeng Liu, Hao Wang, Wei Huang and Chunyan Li
Appl. Sci. 2024, 14(18), 8386; https://doi.org/10.3390/app14188386 - 18 Sep 2024
Viewed by 1445
Abstract
With the rapid development of distribution networks and increasing demand for electricity, the pressure of power supply for medium- and low-voltage distribution networks (M&LVDNs) is increasingly significant, especially considering the large scale of customers at the low-voltage (LV) level. In this paper, an [...] Read more.
With the rapid development of distribution networks and increasing demand for electricity, the pressure of power supply for medium- and low-voltage distribution networks (M&LVDNs) is increasingly significant, especially considering the large scale of customers at the low-voltage (LV) level. In this paper, an outage sequence optimization method for low-voltage distribution networks (LVDNs) that considers the importance of users is proposed. The method aims to develop an optimal outage sequence strategy for LV customers in case of medium-voltage (MV) failure events. First, a multi-dimensional importance indicator system for LV users is constructed, and the customers are ranked using a modified Analytic Hierarchy Process–Entropy Weight (AHP-EW) method to determine their priorities during outages. Then, an elastic net regression-based method is used to identify the topology of the LV network. Finally, an outage sequence optimization model based on the user importance is proposed to reduce the load-shedding level. Extensive case studies are conducted in the modified LV distribution network. The results show that the proposed method results in fewer outage losses throughout the restoration periods than traditional methods and effectively improves the reliability of the power supply to LV users. Full article
(This article belongs to the Section Electrical, Electronics and Communications Engineering)
Show Figures

Figure 1

18 pages, 1264 KiB  
Article
Chernobyl Disaster Optimizer-Based Optimal Integration of Hybrid Photovoltaic Systems and Network Reconfiguration for Reliable and Quality Power Supply to Nuclear Research Reactors
by Sobha Rani Penubarthi, Radha Rani Korrapati, Varaprasad Janamala, Chaitanya Nimmagadda, Arigela Satya Veerendra and Srividya Ravindrakumar
Modelling 2024, 5(3), 1268-1285; https://doi.org/10.3390/modelling5030065 - 13 Sep 2024
Cited by 2 | Viewed by 1648
Abstract
In view of the complexity and importance of nuclear research reactor (NRR) installations, it is imperative to uphold high standards of reliability and quality in the electricity being supplied to them. In this paper, the performance of low-voltage (LV) distribution feeders integrated with [...] Read more.
In view of the complexity and importance of nuclear research reactor (NRR) installations, it is imperative to uphold high standards of reliability and quality in the electricity being supplied to them. In this paper, the performance of low-voltage (LV) distribution feeders integrated with NRRs is improved in terms of reduced distribution loss, improved voltage profile, and reduced greenhouse gas (GHG) emissions by determining the optimal location and size of photovoltaic (PV) systems. In the second stage, the power quality of the feeder is optimized by reducing the total harmonic distortion (THD) by optimally allocating D-STATCOM units. In the third and fourth stages, the reliability and resilience aspects of the feeder are optimized using optimal network reconfiguration (ONR) and by integrating an energy storage system (ESS). To solve the non-linear complex optimization problems at all these stages, an efficient meta-heuristic Chernobyl disaster optimizer (CDO) is proposed. Simulations are performed on a modified IEEE 33-bus feeder considering the non-linear characteristics of NRRs, variability of the feeder loading profile, and PV variability. The study reveals that the proposed methodology can significantly improve the service requirements of NRRs for attaining sustainable research activities. Full article
Show Figures

Figure 1

24 pages, 6604 KiB  
Article
Using Advanced Metering Infrastructure Data from MV/LV Substations to Minimize Reactive Energy Supply Cost to Final Consumers
by Jerzy Andruszkiewicz, Józef Lorenc and Agnieszka Weychan
Energies 2024, 17(16), 4116; https://doi.org/10.3390/en17164116 - 19 Aug 2024
Viewed by 946
Abstract
This article presents an original methodology to determine the optimal level of reactive energy transmission to low-voltage consumers supplied from MV/LV substations that guarantees the lowest total costs of reactive energy transmission through the DSO network and its generation in receiving installations within [...] Read more.
This article presents an original methodology to determine the optimal level of reactive energy transmission to low-voltage consumers supplied from MV/LV substations that guarantees the lowest total costs of reactive energy transmission through the DSO network and its generation in receiving installations within the reactive power compensation process. The average value of the optimal factor tgφ to be maintained by customers depends on the efficiency of the network, the characteristics of the load, and the market costs of energy losses due to the transmission of reactive energy through the network that are covered by the DSO and the costs of reactive energy generation in receiving installations. The results presented for real MV/LV substations operating in the Polish distribution network demonstrate the application of annual measurements of active and reactive energy consumed and generated registered by AMI systems to calculate the optimal reactive power compensation level. They can be applied to verify the permissible levels of reactive energy compensation applied by the DSOs until now within the yearly tariffs for customers. Full article
(This article belongs to the Section F3: Power Electronics)
Show Figures

Figure 1

Back to TopTop