Sign in to use this feature.

Years

Between: -

Subjects

remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline

Journals

remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline

Article Types

Countries / Regions

remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline

Search Results (2,282)

Search Parameters:
Keywords = infrared temperature measurement

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
42 pages, 3116 KB  
Review
An In-Depth Review on Sensing, Heat-Transfer Dynamics, and Predictive Modeling for Aircraft Wheel and Brake Systems
by Lusitha S. Ramachandra, Ian K. Jennions and Nicolas P. Avdelidis
Sensors 2026, 26(3), 921; https://doi.org/10.3390/s26030921 (registering DOI) - 31 Jan 2026
Abstract
An accurate prediction of aircraft wheel and brake (W&B) temperatures is increasingly important for ensuring landing gear safety, supporting turnaround decision-making, and allowing for more effective condition monitoring. Although the thermal behavior of brake assemblies has been studied through component-level testing, analytical formulations, [...] Read more.
An accurate prediction of aircraft wheel and brake (W&B) temperatures is increasingly important for ensuring landing gear safety, supporting turnaround decision-making, and allowing for more effective condition monitoring. Although the thermal behavior of brake assemblies has been studied through component-level testing, analytical formulations, and numerical simulation, current understandings remain fragmented and limited in operational relevance. This paper discusses research across landing gear sensing, thermal modeling, and data-driven prediction to evaluate the state of knowledge supporting a non-intrusive, temperature-centric monitoring framework. Methods surveyed include optical, electromagnetic, acoustic, and infrared sensing techniques as well as traditional machine-learning methods, sequence-based models, and emerging hybrid physics–data approaches. The review synthesizes findings on conduction, convection, and radiation pathways; phase-dependent cooling behavior during landing roll, taxi, and wheel-well retraction; and the capabilities and limitations of existing numerical and empirical models. This study highlights four core gaps: the scarcity of real-flight thermal datasets, insufficient multi-physics integration, limited use of infrared thermography for spatial temperature mapping, and the absence of advanced predictive models for transient brake temperature evolution. Opportunities arise from emissivity-aware infrared thermography, multi-modal dataset development, and machine learning models capable of capturing transient thermal dynamics, while notable challenges relate to measurement uncertainty, environmental sensitivity, model generalization, and deployment constraints. Overall, this review establishes a coherent foundation for thermography-enabled temperature prediction framework for aircraft wheels and brakes. Full article
27 pages, 5961 KB  
Article
Experimental Study of the Effect of Surface Texture in Sliding Contacts Using Infrared Thermography
by Milan Omasta, Tomáš Knoth, Petr Šperka, Michal Hajžman, Ivan Křupka, Pavel Polach and Martin Hartl
Lubricants 2026, 14(2), 64; https://doi.org/10.3390/lubricants14020064 (registering DOI) - 31 Jan 2026
Abstract
This study investigates the influence of surface texturing on temperature distribution in lubricated sliding contacts using infrared thermography. The work addresses the broader challenge of understanding thermal effects in conformal hydrodynamic contacts, where localized heating and viscosity variations can significantly affect tribological performance. [...] Read more.
This study investigates the influence of surface texturing on temperature distribution in lubricated sliding contacts using infrared thermography. The work addresses the broader challenge of understanding thermal effects in conformal hydrodynamic contacts, where localized heating and viscosity variations can significantly affect tribological performance. A pin-on-disc configuration was employed, featuring steel pins with laser-etched micro-dimples that slid against a sapphire disc, allowing for thermal imaging of the contact zone. A dual-bandpass filter infrared thermography technique was developed and rigorously calibrated to distinguish between the temperatures of the steel surface and the lubricant film. Friction measurements and laser-induced fluorescence were used in parallel to assess contact conditions and the behavior of the lubricant film. The results show that surface textures can alter local frictional heating and contribute to non-uniform temperature distributions, particularly in parallel contact geometries. Lubricant temperature was consistently higher than the surface temperature, highlighting the role of shear heating within the fluid film. However, within the tested parameter range, no unambiguous viscosity-wedge signature was identified beyond the dominant temperature-driven viscosity reduction captured by the in situ correction. The method provides a novel means of experimentally resolving temperature fields in sliding textured contacts, offering a valuable foundation for validating thermo-hydrodynamic models in lubricated tribological systems. Full article
(This article belongs to the Special Issue Mechanical Tribology and Surface Technology, 2nd Edition)
Show Figures

Figure 1

19 pages, 2016 KB  
Article
Structure–Property Relationships of Boron Nitride-Reinforced Glass Fiber/Epoxy Laminated Composites
by Sakine Kıratlı and Selçuk Özmen
Polymers 2026, 18(3), 372; https://doi.org/10.3390/polym18030372 - 30 Jan 2026
Abstract
Advances in modern industry largely depend on the development of high-performance materials. In this study, the influence of hexagonal boron nitride (h-BN) filler on the performance of glass fiber/epoxy laminates was systematically investigated. Composites containing h-BN with different particle sizes (65–75 nm and [...] Read more.
Advances in modern industry largely depend on the development of high-performance materials. In this study, the influence of hexagonal boron nitride (h-BN) filler on the performance of glass fiber/epoxy laminates was systematically investigated. Composites containing h-BN with different particle sizes (65–75 nm and 790 nm) and contents (0.2 and 0.4 wt.%) were fabricated, and their mechanical (tensile, in-plane shear, hardness, impact), thermal (Differential Scanning Calorimetry, DSC), electrical (volume resistivity), and spectroscopic (Fourier Transform Infrared Spectroscopy, FTIR) properties were examined. The results demonstrated that specimens with 65–75 nm h-BN at 0.2 wt.% exhibited the highest tensile and shear strengths, whereas those with 790 nm h-BN at 0.4 wt.% showed superior impact resistance and hardness. DSC analyses revealed that h-BN addition increased the glass transition temperature (Tg), while FTIR confirmed interfacial interactions between h-BN and the epoxy matrix. Electrical measurements indicated that h-BN preserved the insulating nature of the composites, with only limited reductions in resistivity observed at higher contents of larger particles due to morphological effects. Overall, these findings highlight that h-BN filler enhances load transfer efficiency, thermal stability, and mechanical reliability, offering significant potential for applications requiring multifunctional performance, such as aerospace, marine, and electrical and electronic insulation systems. Full article
(This article belongs to the Special Issue Fiber-Reinforced Polymer Composites: Progress and Prospects)
Show Figures

Graphical abstract

16 pages, 882 KB  
Article
Experimental Study on the Modified P–V–T Model to Improve Shrinkage Prediction for Injection-Molded Semi-Crystalline Polymer
by Shia-Chung Chen, Yan-Xiang Liang, Chi-Je Ding and Yu-Hung Ting
Polymers 2026, 18(3), 349; https://doi.org/10.3390/polym18030349 - 28 Jan 2026
Viewed by 84
Abstract
Shrinkage of injection-molded parts is a major challenge for dimensional accuracy, especially for semi-crystalline polymers where crystallization induces pronounced volume change and heat release during cooling. Because packing pressure is effective only before gate or local solidification, multi-stage packing is commonly used to [...] Read more.
Shrinkage of injection-molded parts is a major challenge for dimensional accuracy, especially for semi-crystalline polymers where crystallization induces pronounced volume change and heat release during cooling. Because packing pressure is effective only before gate or local solidification, multi-stage packing is commonly used to regulate the overall shrinkage behavior. In practice, however, the solidification/transition temperature taken from standard material tests does not necessarily represent the actual in-cavity state behavior under specific cooling rate and pressure history, which compromises the consistency of P–V–T-based shrinkage prediction. In this study, a modified P–V–T-based framework (Tait equation) is developed for polypropylene (PP) by introducing a Thermal Enthalpy Transformation Method (TETM) to determine a process-relevant solidification time and crystallization-completion temperature (including the corresponding target specific volume) directly from in-cavity melt temperature monitoring using an infrared temperature sensor. The novelty TETM utilizes the crystallization-induced enthalpy release to identify the temperature–time plateau, from which one can identify the effective solidification point. Because the Tait equation adopts a two-domain formulation (molten and solidified states), accurate identification of the domain-switching temperature is critical for reliable shrinkage prediction in practical molding conditions. In the experiment execution, the optimum filling time was defined using the minimum pressure required for melt-filling. Four target specific volumes, three melt temperatures, and two mold temperatures were examined, and a two-stage packing strategy was implemented to achieve comparable shrinkage performance under different target specific volumes. A conventional benchmark based on the solidification temperature reported in the Moldex3D material database was used for comparison only. The results show that the target specific volume determined by the TETM exhibits a more consistent and near-linear relationship with the measured shrinkage rate, demonstrating that the TETM improves the robustness of solidification-time identification and the practical usability of P–V–T information for shrinkage control. Full article
(This article belongs to the Special Issue Advances in Polymer Processing Technologies: Injection Molding)
18 pages, 9659 KB  
Article
Study on Dielectric Properties of Nanoclay-Modified Disulfide-Containing Polyurea Composites
by Xinjian Li, Fan Wang, Haowen Yin, Yang Wang, Guangxi Li, Junjie Huang, Yanhe Yuan, Minghao Zhou, Shuai Zhao, Yingjie Liang, Guangyu Cao and Le Li
Nanomaterials 2026, 16(3), 171; https://doi.org/10.3390/nano16030171 - 27 Jan 2026
Viewed by 106
Abstract
To address the frequent faults (e.g., bird-related hazards, wind deviation) of transmission lines under extreme environments and the limitations of traditional insulating materials (insufficient dielectric properties, poor interface compatibility, etc.), this study synthesized a disulfide-containing polyurea (DPU) with dynamic covalent bonds and prepared [...] Read more.
To address the frequent faults (e.g., bird-related hazards, wind deviation) of transmission lines under extreme environments and the limitations of traditional insulating materials (insufficient dielectric properties, poor interface compatibility, etc.), this study synthesized a disulfide-containing polyurea (DPU) with dynamic covalent bonds and prepared Halloysite nanotubes (HNTs) modified by aminopropyltriethoxysilane (APTES) to form the HNTs/DPU composite. Methods included characterizations like Fourier transform infrared spectroscopy (FTIR), scanning electron microscopy (SEM), differential scanning calorimetry (DSC), and performance tests such as contact angle measurement, breakdown strength, arc resistance, dielectric constant tests, and a tower gap breakdown test. Results showed that APTES modification enhanced interface compatibility, leading to a uniform and dense microstructure. Compared with commercial polyurea (CPU) and commercial insulating sheath (CIS), HNTs/DPU exhibited superior performance: higher glass transition temperature (Tg) and thermal stability, excellent hydrophobicity, improved breakdown strength and dielectric constant, longer arc resistance time by blocking microcrack propagation, and optimal insulation effect at 4 mm coating thickness in the tower gap test with a significantly higher breakdown voltage. In conclusion, HNTs/DPU provides a new technical solution for transmission line insulation protection under extreme conditions, with comparative data demonstrating advancements over existing materials. Full article
Show Figures

Figure 1

14 pages, 2846 KB  
Article
Valorization of Plant Biomass Through the Synthesis of Lignin-Based Hydrogels for Drug Delivery
by Natalia Cárdenas-Vargas, Nazish Jabeen, Jose Huerta-Recasens, Francisco Pérez-Pla, Clara M. Gómez, Maurice N. Collins, Leire Ruiz-Rubio, Rafael Muñoz-Espí and Mario Culebras
Gels 2026, 12(2), 104; https://doi.org/10.3390/gels12020104 - 27 Jan 2026
Viewed by 177
Abstract
This study focuses on obtaining lignin-based hydrogels from pruning residues of orange trees in the Safor region (Valencia) using an alkaline extraction method. The structural analysis of the obtained lignin was carried out using Fourier-transform infrared spectroscopy (FTIR), which revealed the characteristic functional [...] Read more.
This study focuses on obtaining lignin-based hydrogels from pruning residues of orange trees in the Safor region (Valencia) using an alkaline extraction method. The structural analysis of the obtained lignin was carried out using Fourier-transform infrared spectroscopy (FTIR), which revealed the characteristic functional groups of lignin, as well as its structural monolignols: syringyl and guaiacyl. The thermal properties were analyzed using differential scanning calorimetry (DSC) and thermogravimetric analysis. The DSC thermogram revealed a relatively low glass transition temperature (Tg) of 67 °C, which may be attributed to partial lignin chain degradation during alkaline extraction. Soda lignin was obtained at 190 °C with an approximate yield of 10.8% relative to the initial biomass and subsequently used to synthesize poly(vinyl alcohol) (PVA)-based hydrogels for ibuprofen encapsulation. Finally, the release experiments of the encapsulated ibuprofen were carried out in an aqueous phosphate buffer medium (pH = 7) at room temperature. A multi-curve response analysis (MCR) algorithm using the Korsmeyer–Peppas (KP) concentration model was used to analyze the release curves, which concluded that the drug and water-soluble lignin fraction (SLF) were released at different rates. For both components, a good correlation was obtained between the measured responses and those provided by the KP model. The release profile indicated that approximately 87% of the initial ibuprofen load was released from the hydrogel within 5 h, highlighting the promising potential of lignin-based hydrogels for drug delivery applications. Full article
(This article belongs to the Special Issue Design and Optimization of Pharmaceutical Gels (2nd Edition))
Show Figures

Figure 1

19 pages, 2369 KB  
Article
Anatase-Dominant TiO2 Nanoparticles Prepared by Sol–Gel and High-Temperature Calcination
by Y. J. Acosta-Silva, J. Ledesma-García, S. Rivas, A. Alvarez, L. Palma-Tirado, J. F. Pérez-Robles and A. Méndez-López
Appl. Sci. 2026, 16(3), 1258; https://doi.org/10.3390/app16031258 - 26 Jan 2026
Viewed by 274
Abstract
TiO2 nanoparticles were synthesized by a simple sol–gel route followed by high-temperature calcination at 800 °C, aiming to obtain an anatase-dominant reference photocatalyst with enhanced structural stability after severe thermal treatment. Raman spectroscopy and X-ray diffraction confirmed that anatase is the major [...] Read more.
TiO2 nanoparticles were synthesized by a simple sol–gel route followed by high-temperature calcination at 800 °C, aiming to obtain an anatase-dominant reference photocatalyst with enhanced structural stability after severe thermal treatment. Raman spectroscopy and X-ray diffraction confirmed that anatase is the major crystalline phase, with only a minor rutile contribution after calcination at 800 °C. Nitrogen adsorption–desorption measurements revealed a narrow mesoporous contribution arising from interparticle voids and a relatively high specific surface area (108 m2 g−1) despite the severe thermal treatment, while electron microscopy showed nanometric primary particles assembled into compact agglomerates. Surface hydroxyl groups were identified by Fourier-transform infrared spectroscopy, consistent with sol–gel-derived TiO2 systems. Diffuse reflectance UV–Vis spectroscopy combined with Kubelka–Munk and Tauc analysis yielded an optical band gap of 3.12 eV, typical of anatase TiO2. Methylene blue (MB) was used as a probe molecule to evaluate photocatalytic activity under ultraviolet and visible light irradiation. Under UV illumination, degradation kinetics were governed by band-gap excitation and reactive oxygen species generation, whereas a slower but reproducible reference behavior under visible light was predominantly associated with surface-related effects and dye sensitization rather than intrinsic visible-light absorption. Overall, the results establish this anatase-dominant TiO2 as a reliable high-temperature reference photocatalyst, retaining measurable activity after calcination at 800 °C and exhibiting UV-driven behavior as the dominant contribution. Full article
Show Figures

Figure 1

22 pages, 4873 KB  
Article
Button Sample Holders for Infrared Spectroscopy
by Robert L. White
Instruments 2026, 10(1), 5; https://doi.org/10.3390/instruments10010005 - 26 Jan 2026
Viewed by 147
Abstract
The design features and applications of button sample holders are described. The similarities and contrasts between the button method and the transmission cell and attenuated total reflection techniques are discussed. Different button sample holder analysis methodologies are outlined, and examples are provided for [...] Read more.
The design features and applications of button sample holders are described. The similarities and contrasts between the button method and the transmission cell and attenuated total reflection techniques are discussed. Different button sample holder analysis methodologies are outlined, and examples are provided for mid-infrared spectroscopy measurements of solids, liquids, and pastes. Results obtained for 10-nonadecanone powder, a vitamin C tablet, a soil sample, and poly(methyl methacrylate) are used to illustrate different solid sample analysis approaches. Time-dependent spectrum variations detected during evaporation of a blood drop are elucidated and spectra obtained from different quantities of liquid chlorobenzene loaded into buttons and transmission cells are characterized. Infrared spectra derived from three toothpaste brands are compared and a sample perturbation study to identify temperature-dependent changes to the structure of poly(bisphenol A carbonate) is provided as an example of variable temperature infrared spectroscopy. Full article
(This article belongs to the Section Optical and Photonic Instruments)
Show Figures

Figure 1

22 pages, 4317 KB  
Article
Non-Contact Temperature Monitoring in Dairy Cattle via Thermal Infrared Imaging and Environmental Parameters
by Kaixuan Zhao, Shaojuan Ge, Yinan Chen, Qianwen Li, Mengyun Guo, Yue Nian and Wenkai Ren
Agriculture 2026, 16(3), 306; https://doi.org/10.3390/agriculture16030306 - 26 Jan 2026
Viewed by 153
Abstract
Core body temperature is a critical physiological indicator for assessing and diagnosing animal health status. In bovines, continuously monitoring this metric enables accurate evaluation of their physiological condition; however, traditional rectal measurements are labor-intensive and cause stress in animals. To achieve intelligent, contactless [...] Read more.
Core body temperature is a critical physiological indicator for assessing and diagnosing animal health status. In bovines, continuously monitoring this metric enables accurate evaluation of their physiological condition; however, traditional rectal measurements are labor-intensive and cause stress in animals. To achieve intelligent, contactless temperature monitoring in cattle, we proposed a non-invasive method based on thermal imaging combined with environmental data fusion. First, thermal infrared images of the cows’ faces were collected, and the You Only Look Once (YOLO) object detection model was used to locate the head region. Then, the YOLO segmentation network was enhanced with the Online Convolutional Re-parameterization (OREPA) and High-level Screening-feature Fusion Pyramid Network (HS-FPN) modules to perform instance segmentation of the eye socket area. Finally, environmental variables—ambient temperature, humidity, wind speed, and light intensity—were integrated to compensate for eye socket temperature, and a random forest algorithm was used to construct a predictive model of rectal temperature. The experiments were conducted using a thermal infrared image dataset comprising 33,450 frontal-view images of dairy cows with a resolution of 384 × 288 pixels, along with 1471 paired samples combining thermal and environmental data for model development. The proposed method achieved a segmentation accuracy (mean average precision, mAP50–95) of 86.59% for the eye socket region, ensuring reliable temperature extraction. The rectal temperature prediction model demonstrated a strong correlation with the reference rectal temperature (R2 = 0.852), confirming its robustness and predictive reliability for practical applications. These results demonstrate that the proposed method is practical for non-contact temperature monitoring of cattle in large-scale farms, particularly those operating under confined or semi-confined housing conditions. Full article
(This article belongs to the Section Farm Animal Production)
Show Figures

Figure 1

28 pages, 3376 KB  
Article
Perfluorocarbon Nanoemulsions for Simultaneous Delivery of Oxygen and Antioxidants During Machine Perfusion Supported Organ Preservation
by Smith Patel, Paromita Paul Pinky, Amit Chandra Das, Joshua S. Copus, Chip Aardema, Caitlin Crelli, Anneliese Troidle, Eric Lambert, Rebecca McCallin, Vidya Surti, Carrie DiMarzio, Varun Kopparthy and Jelena M. Janjic
Pharmaceutics 2026, 18(2), 143; https://doi.org/10.3390/pharmaceutics18020143 - 23 Jan 2026
Viewed by 462
Abstract
Background: Solid organ transplantation (SOT) is a life-saving treatment for patients with end-stage diseases and/or organ failure. However, access to healthy organs is often limited by challenges in organ preservation. Furthermore, upon transplantation, ischemia–reperfusion injury (IRI) can lead to increased organ rejection or [...] Read more.
Background: Solid organ transplantation (SOT) is a life-saving treatment for patients with end-stage diseases and/or organ failure. However, access to healthy organs is often limited by challenges in organ preservation. Furthermore, upon transplantation, ischemia–reperfusion injury (IRI) can lead to increased organ rejection or graft failures. The work presented aims to address both challenges using an innovative nanomedicine platform for simultaneous drug and oxygen delivery. In recent studies, resveratrol (RSV), a natural antioxidant, anti-inflammatory, and reactive oxygen species (ROS) scavenging agent, has been reported to protect against IRI by inhibiting ferroptosis. Here, we report the design, development, and scalable manufacturing of the first-in-class dual-function perfluorocarbon-nanoemulsion (PFC-NE) perfusate for simultaneous oxygen and antioxidant delivery, equipped with a near-infrared fluorescence (NIRF) reporter, longitudinal, non-invasive NIRF imaging of perfusate flow through organs/tissues during machine perfusion. Methods: A Quality-by-Design (QbD)-guided optimization was used to formulate a triphasic PFC-NE with 30% w/v perfluorooctyl bromide (PFOB). Drug-free perfluorocarbon nanoemulsions (DF-NEs) and RSV-loaded nanoemulsions (RSV-NEs) were produced at 250–1000 mL scales using M110S, LM20, and M110P microfluidizers. Colloidal attributes, fluorescence stability, drug loading, and RSV release were evaluated using DLS, NIRF imaging, and HPLC, respectively. PFC-NE oxygen loading and release kinetics were evaluated during perfusion through the BMI OrganBank® machine with the MEDOS HILITE® oxygenator and by controlled flow of oxygen. The in vitro antioxidant activity of RSV-NE was measured using the oxygen radical scavenging antioxidant capacity (ORAC) assay. The cytotoxicity and ferroptosis inhibition of RSV-NE were evaluated in RAW 264.7 macrophages. Results: PFC-NE batches maintained a consistent droplet size (90–110 nm) and low polydispersity index (<0.3) across all scales, with high reproducibility and >80% PFOB loading. Both DF-NE and RSV-NE maintained colloidal and fluorescence stability under centrifugation, serum exposure at body temperature, filtration, 3-month storage, and oxygenation. Furthermore, RSV-NE showed high drug loading and sustained release (63.37 ± 2.48% at day 5) compared with the rapid release observed in free RSV solution. In perfusion studies, the oxygenation capacity of PFC-NE consistently exceeded that of University of Wisconsin (UW) solution and demonstrated stable, linear gas responsiveness across flow rates and FiO2 (fraction of inspired oxygen) inputs. RSV-NE displayed strong antioxidant activity and concentration-dependent inhibition of free radicals. RSV-NE maintained higher cell viability and prevented RAS-selective lethal compound 3 (RSL3)-induced ferroptosis in murine macrophages (macrophage cell line RAW 264.7), compared to the free RSV solution. Morphological and functional protection against RSL3-induced ferroptosis was confirmed microscopically. Conclusions: This study establishes a robust and scalable PFC-NE platform integrating antioxidant and oxygen delivery, along with NIRF-based non-invasive live monitoring of organ perfusion during machine-supported preservation. These combined features position PFC-NE as a promising next-generation acellular perfusate for preventing IRI and improving graft viability during ex vivo machine perfusion. Full article
(This article belongs to the Special Issue Methods of Potentially Improving Drug Permeation and Bioavailability)
Show Figures

Graphical abstract

10 pages, 223 KB  
Article
Validation of Infrared Thermal Imaging for Grading of Cellulite Severity: Correlation with Clinical and Anthropometric Assessments
by Patrycja Szczepańska-Ciszewska, Andrzej Śliwczyński, Bartosz Mruk, Wojciech Michał Glinkowski, Patryk Wicher, Adam Sulimski and Anna Wicher
J. Clin. Med. 2026, 15(2), 913; https://doi.org/10.3390/jcm15020913 - 22 Jan 2026
Viewed by 117
Abstract
Background/Objectives: Cellulite is a common aesthetic condition in women, traditionally assessed using visual inspection and palpation-based scales that are inherently subjective. Therefore, image-based methods that may support standardized severity grading are of growing interest. To evaluate infrared thermography as an imaging-based method for [...] Read more.
Background/Objectives: Cellulite is a common aesthetic condition in women, traditionally assessed using visual inspection and palpation-based scales that are inherently subjective. Therefore, image-based methods that may support standardized severity grading are of growing interest. To evaluate infrared thermography as an imaging-based method for grading cellulite severity and to perform methodological validation of a newly developed thermographic classification scale by comparing it with clinical palpation and anthropometric parameters. Methods: This retrospective, non-interventional study analyzed anonymized clinical and thermographic data from 81 women with clinically assessed cellulite. Cellulite severity was evaluated using the Nürnberger–Müller palpation scale and a newly developed five-point thermographic scale based on skin surface temperature differentials and histogram pattern analysis. The associations between the assessment methods were evaluated using ordinal statistical measures, and agreement was assessed using weighted Cohen’s kappa statistics. Results: Thermographic grading demonstrated high agreement with palpation-based assessment, with a percentage agreement of 93.8% and an almost perfect agreement based on weighted Cohen’s κ. A strong ordinal association was observed between the methods. Thermography consistently classified a subset of cases as one grade higher compared with palpation. No statistically significant associations were observed between thermographic grade and body mass index or waist-to-hip ratio. Conclusions: Infrared thermography enables image-based grading of cellulite severity and shows a strong concordance with established palpation scales. The proposed thermographic classification provides preliminary methodological validation of an imaging-based grading approach. Further multicenter studies involving multiple assessors and diverse populations are required to assess reproducibility, specificity, and potential clinical applicability. Full article
(This article belongs to the Section Dermatology)
25 pages, 7120 KB  
Article
Non-Imaging Optics as Radiative Cooling Enhancers: An Empirical Performance Characterization
by Edgar Saavedra, Guillermo del Campo, Igor Gomez, Juan Carrero, Adrian Perez and Asuncion Santamaria
Urban Sci. 2026, 10(1), 64; https://doi.org/10.3390/urbansci10010064 - 20 Jan 2026
Viewed by 1128
Abstract
Radiative cooling (RC) offers a passive pathway to reduce surface and system temperatures by emitting thermal radiation through the atmospheric window, yet its daytime effectiveness is often constrained by geometry, angular solar exposure, and practical integration limits. This work experimentally investigates the use [...] Read more.
Radiative cooling (RC) offers a passive pathway to reduce surface and system temperatures by emitting thermal radiation through the atmospheric window, yet its daytime effectiveness is often constrained by geometry, angular solar exposure, and practical integration limits. This work experimentally investigates the use of passive non-imaging optics, specifically compound parabolic concentrators (CPCs), as enhancers of RC performance under realistic conditions. A three-tier experimental methodology is followed. First, controlled indoor screening using an infrared lamp quantifies the intrinsic heat gain suppression of a commercial RC film, showing a temperature reduction of nearly 88 °C relative to a black-painted reference. Second, outdoor rooftop experiments on aluminum plates assess partial RC coverage, with and without CPCs, under varying orientations and tilt angles, revealing peak daytime temperature reductions close to 8 °C when CPCs are integrated. Third, system-level validation is conducted using a modified GUNT ET-202 solar thermal unit to evaluate the transfer of RC effects to a water circuit absorber. While RC strips alone produce modest reductions in water temperature, the addition of CPC optics amplifies the effect by factors of approximately three for ambient water and nine for water at 70 °C. Across all configurations, statistical analysis confirms stable, repeatable measurements. These results demonstrate that coupling commercially available RC materials with non-imaging optics provides consistent and measurable performance gains, supporting CPC-assisted RC as a scalable and retrofit-friendly strategy for urban and building energy applications while calling for longer-term experiments, durability assessments, and techno-economic analysis before deriving definitive deployment guidelines. Full article
Show Figures

Figure 1

25 pages, 3441 KB  
Article
The Surface Is Not Superficial: Utilizing Hyper-Local Thermal Photogrammetry for Pedestrian Thermal Comfort Inquiry
by Logan Steinharter, Peter C. Ibsen, Priyanka deSouza and Melissa R. McHale
Remote Sens. 2026, 18(2), 348; https://doi.org/10.3390/rs18020348 - 20 Jan 2026
Viewed by 135
Abstract
The scale and magnitude of urban heating are often assessed using Satellite-Derived Land Surface Temperature (SD-LST). Yet, discrepancies in spatial resolution limit SD-LST’s ability to reflect pedestrian thermal experience, potentially leading to ineffective mitigation strategies. Hyper-local measurements of urban heat, defined as surface [...] Read more.
The scale and magnitude of urban heating are often assessed using Satellite-Derived Land Surface Temperature (SD-LST). Yet, discrepancies in spatial resolution limit SD-LST’s ability to reflect pedestrian thermal experience, potentially leading to ineffective mitigation strategies. Hyper-local measurements of urban heat, defined as surface temperatures (TS) at the scale of pedestrian activity (e.g., bus stops or street segments), may provide more accurate insights into thermal comfort. This study compares hyper-local ~0.01 m resolution TS collected via consumer-grade Forward-Looking Infrared (FLIR) thermography with resampled 30 m resolution SD-LST from Landsat 8 and 9 images to evaluate their utility in predicting thermal comfort indices across 60 bus stops in Denver, Colorado. During the summer of 2023, 270 FLIR measurements were collected over 19 dates, with a four-day subset (n = 33) coinciding with Landsat imagery. FLIR TS averaged 25.12 ± 5.39 °C, while SD-LST averaged 35.90 ± 12.56 °C, a significant 10.77 °C difference (95% CI: 6.81–14.73; p < 0.001). FLIR TS strongly correlated with biometeorological metrics such as air temperature and mean radiant temperature (r > 0.8; p < 0.001), while SD-LST correlations were weak (r < 0.3). Linear mixed-effects models using FLIR TS explained 50–66% of the variance in thermal comfort indices and met ISO 7726 standards. Each 1 °C increase in FLIR TS predicted a 0.75 °C rise in mean radiant temperature. These results highlight hyper-local thermography as a reliable, low-cost tool for urban heat resilience planning. Full article
Show Figures

Figure 1

23 pages, 6305 KB  
Article
Processing and Characterization of Poly(lactic acid) (PLA) Films Containing Pomegranate Peel Powder
by Ömer Faruk Uslu, David Krieg, Benedikt Theodor Hiller, Özge Taştan Ülkü and Nebahat Aral
Polymers 2026, 18(2), 274; https://doi.org/10.3390/polym18020274 - 20 Jan 2026
Viewed by 348
Abstract
The present study analyses the changes in antioxidative behavior of biodegradable Poly(lactic acid) (PLA)-based composite films with bioactive additives derived from pomegranate peel, an abundant agricultural by-product rich in antioxidants and antimicrobials. PLA-based composites were prepared by incorporating industrial-grade pomegranate peel powder (PoP) [...] Read more.
The present study analyses the changes in antioxidative behavior of biodegradable Poly(lactic acid) (PLA)-based composite films with bioactive additives derived from pomegranate peel, an abundant agricultural by-product rich in antioxidants and antimicrobials. PLA-based composites were prepared by incorporating industrial-grade pomegranate peel powder (PoP) via melt extrusion at concentrations of 1–5 percent by weight (wt.%). For mechanical characterization, the resulting films were subjected to tensile testing. Their thermal properties were further characterized using thermogravimetric analysis (TGA), differential scanning calorimetry (DSC), dynamic oxidation induction temperature measurements (OIT), complemented by Fourier-transform infrared spectroscopy (FT-IR), color analysis, rheology, scanning electron microscopy (SEM), and UV-Vis spectroscopy. Results show that the incorporation of PoP had no significant impact on the characteristic transition temperatures (Tg, Tm, and Tc) of PLA, indicating that the thermal behavior of the polymer matrix was largely preserved. However, while the thermo-oxidative stability of PLA was improved in the presence of PoP, with a maximum at 3 wt.% of PoP, increasing the OIT by 30 °C, the mechanical performance of the composite films was adversely affected, as evidenced by decreased tensile strength and elongation at break indication embrittlement, especially for ≥3 wt.% of PoP. Significant changes were observed in the films’ surface properties, as well as in their color parameters and UV transmittance values. Consequently, while PoP offers potential bioactive functionality for use as a sustainable additive, its content must be carefully optimized to maintain an acceptable balance between functionality and mechanical integrity. Full article
(This article belongs to the Section Polymer Applications)
Show Figures

Graphical abstract

17 pages, 1796 KB  
Article
Ultrasonic–Laser Hybrid Treatment for Cleaning Gasoline Engine Exhaust: An Experimental Study
by Bauyrzhan Sarsembekov, Madi Issabayev, Nursultan Zharkenov, Altynbek Kaukarov, Isatai Utebayev, Akhmet Murzagaliyev and Baurzhan Zhamanbayev
Vehicles 2026, 8(1), 22; https://doi.org/10.3390/vehicles8010022 - 20 Jan 2026
Viewed by 285
Abstract
Vehicle exhaust gases remain one of the key sources of atmospheric air pollution and pose a serious threat to ecosystems and public health. This study presents an experimental investigation into reducing the toxicity of gasoline internal combustion engine exhaust using ultrasonic waves and [...] Read more.
Vehicle exhaust gases remain one of the key sources of atmospheric air pollution and pose a serious threat to ecosystems and public health. This study presents an experimental investigation into reducing the toxicity of gasoline internal combustion engine exhaust using ultrasonic waves and infrared (IR) laser exposure. An original hybrid system integrating an ultrasonic emitter and an IR laser module was developed. Four operating modes were examined: no treatment, ultrasound only, laser only, and combined ultrasound–laser treatment. The concentrations of CH, CO, CO2, and O2, as well as exhaust gas temperature, were measured at idle and under operating engine speeds. The experimental results show that ultrasound provides a substantial reduction in CO concentration (up to 40%), while IR laser exposure effectively decreases unburned hydrocarbons CH (by 35–40%). The combined treatment produces a synergistic effect, reducing CH and CO by 38% and 43%, respectively, while increasing the CO2 fraction and decreasing O2 content, indicating more complete post-oxidation of combustion products. The underlying physical mechanisms responsible for the purification were identified as acoustic coagulation of particulates, oxidation, and photodissociation of harmful molecules. The findings support the hypothesis that combined ultrasonic and laser treatment can enhance real-time exhaust gas purification efficiency. It is demonstrated that physical treatment of the gas phase not only lowers the persistence of by-products but also promotes more complete oxidation processes within the flow. Full article
(This article belongs to the Special Issue Intelligent Mobility and Sustainable Automotive Technologies)
Show Figures

Figure 1

Back to TopTop