Sign in to use this feature.

Years

Between: -

Subjects

remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline

Journals

Article Types

Countries / Regions

Search Results (13)

Search Parameters:
Keywords = heavy-ion beam probe

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
20 pages, 1317 KB  
Review
Overview of Target Normal Sheath Acceleration Experiments and Diagnostics at SPARC_LAB
by Federica Stocchi, Maria Pia Anania, Fabrizio Bisesto, Alessandro Cianchi, Mattia Cipriani, Fabrizio Consoli, Gemma Costa, Alessandro Curcio, Mario Galletti, Riccardo Pompili, Martina Salvadori, Claudio Verona, Arie Zigler and Massimo Ferrario
Appl. Sci. 2025, 15(24), 13001; https://doi.org/10.3390/app152413001 - 10 Dec 2025
Viewed by 1241
Abstract
The interaction of an ultra-short, high-power laser pulse with a solid target, in the so-called Target Normal Sheath Acceleration (TNSA) configuration, produces particles in the MeV range. Fast electrons can escape from the target after the interaction, inducing electrostatic fields on the order [...] Read more.
The interaction of an ultra-short, high-power laser pulse with a solid target, in the so-called Target Normal Sheath Acceleration (TNSA) configuration, produces particles in the MeV range. Fast electrons can escape from the target after the interaction, inducing electrostatic fields on the order of TV/m close to the target surface. These fields accelerate MeV protons and heavy ions at the rear of the target, allowing them to escape. The complete process is difficult to probe, as it occurs on the sub-ps timescale. At the INFN-LNF SPARC_LAB test facility, single-shot diagnostics such as the Electro-Optic Sampling (EOS) are being developed and tested for time-resolved direct measurements of the produced electrons and associated longitudinal electric fields. Electrons are the core of the process, and their properties determine the following production of positive charge particles and electromagnetic radiation. Different target geometries and materials are being investigated to analyze the enhancement of fast electron emission and the correlation with positive charge production. Simultaneous observations of electron and proton beams have been performed using two diagnostic lines, the EOS for electrons and a time-of-flight (TOF) detector for protons. This work provides an overview of the previous experiments performed at SPARC_LAB dedicated to the TNSA characterization. Full article
(This article belongs to the Special Issue Trends and Prospects in Laser–Plasma Accelerator)
Show Figures

Figure 1

14 pages, 3331 KB  
Article
Portable Magnetic Field Mapping Measurement System Based on Large-Scale Dipole Magnets in HIAF
by Xiang Zhang, Zidi Wu, Li’an Jin, Jing Yang, Xianjin Ou, Dongsheng Ni, Yue Cheng, Lixia Zhao, Yujin Tong, Weigang Dong, Beimin Wu, Guohong Li and Qinggao Yao
Metrology 2025, 5(2), 22; https://doi.org/10.3390/metrology5020022 - 14 Apr 2025
Viewed by 1752
Abstract
The High-Intensity Heavy-Ion Accelerator Facility (HIAF) is a significant national science and technology infrastructure project, constructed by the Institute of Modern Physics, Chinese Academy of Sciences (IMP, CAS). It is designed to provide intense proton, heavy ion beams, and target-produced radioactive ion beams [...] Read more.
The High-Intensity Heavy-Ion Accelerator Facility (HIAF) is a significant national science and technology infrastructure project, constructed by the Institute of Modern Physics, Chinese Academy of Sciences (IMP, CAS). It is designed to provide intense proton, heavy ion beams, and target-produced radioactive ion beams for nuclear physics and related research. Large-aperture, high-precision, room-temperature, and superconducting dipole magnets are extensively used to achieve high-intensity beams. However, for large-scale magnets (particularly superconducting magnets), the traditional Hall probe mapping measurement platform encounters several limitations: a long preparation time, high cost, low testing efficiency, and positional inaccuracies caused by repeated magnet disassembly. This paper presents a new magnetic field mapping measurement system incorporating ultrasonic motors operable in strong magnetic fields (≥7 T), enabling portable, highly efficient, and high-precision magnetic field measurements. After system integration and commissioning, the prototype dipole magnet for the high-precision spectrometer ring (SRing) was measured. The measurement system demonstrated superior accuracy and efficiency compared with traditional Hall probe mapping systems. On this basis, the magnetic field distribution and integral excitation curve of all 11 warm-iron superconducting dipole magnets and 3 anti-irradiation dipole magnets in the HIAF fragment separator (HFRS) were measured. Each magnet took less than 1 day to measure, and all magnetic field measurement results met the physical specifications. Full article
(This article belongs to the Special Issue Advances in Magnetic Measurements)
Show Figures

Figure 1

8 pages, 490 KB  
Article
Diagnostics of Spin-Polarized Ions at Storage Rings
by Anna Maiorova, Stephan Fritzsche, Andrey Surzhykov and Thomas Stöhlker
Atoms 2025, 13(2), 15; https://doi.org/10.3390/atoms13020015 - 4 Feb 2025
Viewed by 1536
Abstract
Polarized heavy ions in storage rings are seen as a valuable tool for a wide range of research, from the study of spin effects in relativistic atomic collisions to the tests of the Standard Model. For forthcoming experiments, several important challenges need to [...] Read more.
Polarized heavy ions in storage rings are seen as a valuable tool for a wide range of research, from the study of spin effects in relativistic atomic collisions to the tests of the Standard Model. For forthcoming experiments, several important challenges need to be addressed to work efficiently with such ions. Apart from the production and preservation of ion polarization in storage rings, its measurement is an extremely important issue. In this contribution, we employ the radiative recombination (RR) of polarized electrons into the ground state of initially hydrogen-like, finally helium-like, ions as a probe process for beam diagnostics. Our theoretical study clearly demonstrates that the RR cross section, integrated over photon emission angles, is highly sensitive to both the degree and the direction of ion polarization. Since the (integrated) cross-section measurements are well established, the proposed method offers promising prospects for ion spin tomography at storage rings. Full article
(This article belongs to the Special Issue 21st International Conference on the Physics of Highly Charged Ions)
Show Figures

Figure 1

17 pages, 481 KB  
Article
Angular Distributions and Polarization of Fluorescence in an XUV Pump–XUV Probe Scheme
by Cristian Iorga and Viorica Stancalie
Atoms 2025, 13(1), 1; https://doi.org/10.3390/atoms13010001 - 24 Dec 2024
Cited by 2 | Viewed by 1812
Abstract
This work provides theoretical calculations of fluorescence angular distribution and polarization within an XUV pump–XUV probe scheme designed for determining ultra-short lifetimes of highly charged heavy ions. The initial pumping leads to a non-zero alignment in the excited levels. After the probing stage, [...] Read more.
This work provides theoretical calculations of fluorescence angular distribution and polarization within an XUV pump–XUV probe scheme designed for determining ultra-short lifetimes of highly charged heavy ions. The initial pumping leads to a non-zero alignment in the excited levels. After the probing stage, the anisotropies in angular distribution and polarization of subsequent fluorescence are significantly enhanced due to the existence of a previous alignment. Furthermore, two-photon sequential excitation from a ground state with zero angular momentum to a level with angular momentum one by two aligned linearly polarized photon beams is strictly prohibited by the selection rules and may be used as a diagnostic tool to determine beam misalignment. The present approach is based on the density matrix and statistical tensor framework. We provide the analytical form for the alignment parameters caused by successive photoexcitation either with linearly polarized photon beams, or with unpolarized photons. The analytical results can generally be used to compute angular distribution asymmetry parameters and linear polarization of subsequent fluorescence for a large array of atomic systems used in pump–probe experiments. Full article
Show Figures

Figure 1

10 pages, 2718 KB  
Article
Measurement and Simulation of Ultra-Low-Energy Ion–Solid Interaction Dynamics
by Michael Titze, Jonathan D. Poplawsky, Silvan Kretschmer, Arkady V. Krasheninnikov, Barney L. Doyle, Edward S. Bielejec, Gerhard Hobler and Alex Belianinov
Micromachines 2023, 14(10), 1884; https://doi.org/10.3390/mi14101884 - 30 Sep 2023
Cited by 1 | Viewed by 3700
Abstract
Ion implantation is a key capability for the semiconductor industry. As devices shrink, novel materials enter the manufacturing line, and quantum technologies transition to being more mainstream. Traditional implantation methods fall short in terms of energy, ion species, and positional precision. Here, we [...] Read more.
Ion implantation is a key capability for the semiconductor industry. As devices shrink, novel materials enter the manufacturing line, and quantum technologies transition to being more mainstream. Traditional implantation methods fall short in terms of energy, ion species, and positional precision. Here, we demonstrate 1 keV focused ion beam Au implantation into Si and validate the results via atom probe tomography. We show the Au implant depth at 1 keV is 0.8 nm and that identical results for low-energy ion implants can be achieved by either lowering the column voltage or decelerating ions using bias while maintaining a sub-micron beam focus. We compare our experimental results to static calculations using SRIM and dynamic calculations using binary collision approximation codes TRIDYN and IMSIL. A large discrepancy between the static and dynamic simulation is found, which is due to lattice enrichment with high-stopping-power Au and surface sputtering. Additionally, we demonstrate how model details are particularly important to the simulation of these low-energy heavy-ion implantations. Finally, we discuss how our results pave a way towards much lower implantation energies while maintaining high spatial resolution. Full article
Show Figures

Figure 1

34 pages, 11195 KB  
Review
Review of Recent Advances in Gas-Assisted Focused Ion Beam Time-of-Flight Secondary Ion Mass Spectrometry (FIB-TOF-SIMS)
by Agnieszka Priebe and Johann Michler
Materials 2023, 16(5), 2090; https://doi.org/10.3390/ma16052090 - 3 Mar 2023
Cited by 24 | Viewed by 9954
Abstract
Time-of-flight secondary ion mass spectrometry (TOF-SIMS) is a powerful chemical characterization technique allowing for the distribution of all material components (including light and heavy elements and molecules) to be analyzed in 3D with nanoscale resolution. Furthermore, the sample’s surface can be probed over [...] Read more.
Time-of-flight secondary ion mass spectrometry (TOF-SIMS) is a powerful chemical characterization technique allowing for the distribution of all material components (including light and heavy elements and molecules) to be analyzed in 3D with nanoscale resolution. Furthermore, the sample’s surface can be probed over a wide analytical area range (usually between 1 µm2 and 104 µm2) providing insights into local variations in sample composition, as well as giving a general overview of the sample’s structure. Finally, as long as the sample’s surface is flat and conductive, no additional sample preparation is needed prior to TOF-SIMS measurements. Despite many advantages, TOF-SIMS analysis can be challenging, especially in the case of weakly ionizing elements. Furthermore, mass interference, different component polarity of complex samples, and matrix effect are the main drawbacks of this technique. This implies a strong need for developing new methods, which could help improve TOF-SIMS signal quality and facilitate data interpretation. In this review, we primarily focus on gas-assisted TOF-SIMS, which has proven to have potential for overcoming most of the aforementioned difficulties. In particular, the recently proposed use of XeF2 during sample bombardment with a Ga+ primary ion beam exhibits outstanding properties, which can lead to significant positive secondary ion yield enhancement, separation of mass interference, and inversion of secondary ion charge polarity from negative to positive. The implementation of the presented experimental protocols can be easily achieved by upgrading commonly used focused ion beam/scanning electron microscopes (FIB/SEM) with a high vacuum (HV)-compatible TOF-SIMS detector and a commercial gas injection system (GIS), making it an attractive solution for both academic centers and the industrial sectors. Full article
Show Figures

Figure 1

13 pages, 2271 KB  
Article
Heavy Ion Beam Probing Diagnostics on the TUMAN-3M Tokamak for Study Plasma Potential and Electric Fields in New Operational Regimes
by Leonid Askinazi, Gulnara Abdullina, Alexander Belokurov, Vladimir Kornev, Sergei Lebedev, Dmitri Razumenko, Dmitri Shergin, Alexander Smirnov, Alexander Tukachinsky and Nikolai Zhubr
Atoms 2022, 10(4), 152; https://doi.org/10.3390/atoms10040152 - 14 Dec 2022
Cited by 2 | Viewed by 2621
Abstract
Heavy Ion Beam Probing (HIBP) diagnostic is a powerful tool for electric field studies in the hot dense plasma of modern-day toroidal magnetic confinement devices. On the TUMAN-3M tokamak, the HIBP have been used in regimes with improved plasma confinement to clear up [...] Read more.
Heavy Ion Beam Probing (HIBP) diagnostic is a powerful tool for electric field studies in the hot dense plasma of modern-day toroidal magnetic confinement devices. On the TUMAN-3M tokamak, the HIBP have been used in regimes with improved plasma confinement to clear up the role of the radial electric field in the transition to good confinement regimes. Recently, a modernization of the TUMAN-3M HIBP diagnostics was performed, aiming to reconfigure it for a work with a reversed plasma current direction and improvement of the overall stability of the diagnostic. The results of the first measurements of the plasma potential in the co-NBI scenario are reported and discussed. Full article
(This article belongs to the Special Issue Neutral Atoms in Controlled Fusion and Space Plasmas)
Show Figures

Figure 1

14 pages, 5816 KB  
Article
Affect of Secondary Beam Non-Uniformity on Plasma Potential Measurements by HIBD with Split-Plate Detector
by Igor Nedzelskiy, Artur Malaquias, Rafael Henriques and Ridhima Sharma
Sensors 2022, 22(14), 5135; https://doi.org/10.3390/s22145135 - 8 Jul 2022
Viewed by 2199
Abstract
In a Heavy Ion Beam Diagnostic (HIBD), the plasma potential is obtained by measuring the energy of the secondary ions resulting from beam-plasma collisions by an electrostatic energy analyzer with split-plate detector (SPD), which relates the secondary ion beam energy variation to its [...] Read more.
In a Heavy Ion Beam Diagnostic (HIBD), the plasma potential is obtained by measuring the energy of the secondary ions resulting from beam-plasma collisions by an electrostatic energy analyzer with split-plate detector (SPD), which relates the secondary ion beam energy variation to its position determined by the difference in currents between the split plates. Conventionally, the data from SPD are analyzed with the assumption that the secondary beam current is uniform. However, the secondary beam presents an effective projection of the primary beam, the current of which, as a rule, has a bell-like non-uniform profile. This paper presents: (i) the general features of the secondary beam profile formation, considered in the simplistic approximation of the circular primary beam and the secondary ions that emerge orthogonal to the primary beam axis, (ii) details of spit-plate detection and the influence of the secondary beam non-uniformity on plasma potential measurements, (iii) supported experimental data from the tokamak ISTTOK HIBD for primary and secondary beam profiles and the SPD transfer characteristic, obtained for the 90° cylindrical energy analyzer (90° CEA) and (iv) the implementation of a multiple cell array detector (MCAD) with dedicated resolution for the measurements of secondary beam profile and MCAD operation in multi-split-plate detection mode for direct measurements of the SPD transfer characteristic. Full article
(This article belongs to the Special Issue Plasma Diagnostics)
Show Figures

Figure 1

28 pages, 10527 KB  
Article
The Heavy-Ion Beam Diagnostic of the ISTTOK Tokamak—Highlights and Recent Developments
by A. Malaquias, I. S. Nedzelskiy, R. Henriques and R. Sharma
Sensors 2022, 22(11), 4038; https://doi.org/10.3390/s22114038 - 26 May 2022
Cited by 5 | Viewed by 2638
Abstract
The unique arrangement of the heavy-ion beam diagnostic in ISTTOK enables one to measure the evolution of temperature, density and pressure-like profiles in normal and AC discharges. The fast chopping beam technique provided the possibility to reduce the noise on the measurements of [...] Read more.
The unique arrangement of the heavy-ion beam diagnostic in ISTTOK enables one to measure the evolution of temperature, density and pressure-like profiles in normal and AC discharges. The fast chopping beam technique provided the possibility to reduce the noise on the measurements of the plasma pressure-like profile and for the precise control of the plasma column position in real time. The consequent improvements in S/N levels allowed the observation of the effects of runaway beam magnetic energy conversion into plasma local heating. In addition, it made it possible to follow the evolution of the quiescent plasma maintained during AC transitions when the plasma current is null. The use of a new operation mode in the cylindrical energy analyzer provided an improved resolution up to five times in determining the fluctuations of the plasma potential as compared to the normal operation mode. Such analyzer is extremely compact (250 mm × 250 mm × 120 mm) and provides a unique geometry in order to cover the whole plasma diameter. The detector configuration choice gives the possibility for the simultaneous measurements of plasma poloidal magnetic field, plasma pressure-like and plasma potential profiles together with their fluctuations. Full article
(This article belongs to the Special Issue Plasma Diagnostics)
Show Figures

Figure 1

18 pages, 6649 KB  
Review
Silicon 3D Microdosimeters for Advanced Quality Assurance in Particle Therapy
by Linh T. Tran, David Bolst, Benjamin James, Vladimir Pan, James Vohradsky, Stefania Peracchi, Lachlan Chartier, Emily Debrot, Susana Guatelli, Marco Petasecca, Michael Lerch, Dale Prokopovich, Željko Pastuović, Marco Povoli, Angela Kok, Taku Inaniwa, Sung Hyun Lee, Naruhiro Matsufuji and Anatoly B. Rosenfeld
Appl. Sci. 2022, 12(1), 328; https://doi.org/10.3390/app12010328 - 30 Dec 2021
Cited by 34 | Viewed by 5183
Abstract
The Centre for Medical Radiation Physics introduced the concept of Silicon On Insulator (SOI) microdosimeters with 3-Dimensional (3D) cylindrical sensitive volumes (SVs) mimicking the dimensions of cells in an array. Several designs of high-definition 3D SVs fabricated using 3D MEMS technology were implemented. [...] Read more.
The Centre for Medical Radiation Physics introduced the concept of Silicon On Insulator (SOI) microdosimeters with 3-Dimensional (3D) cylindrical sensitive volumes (SVs) mimicking the dimensions of cells in an array. Several designs of high-definition 3D SVs fabricated using 3D MEMS technology were implemented. 3D SVs were fabricated in different sizes and configurations with diameters between 18 and 30 µm, thicknesses of 2–50 µm and at a pitch of 50 µm in matrices with volumes of 20 × 20 and 50 × 50. SVs were segmented into sub-arrays to reduce capacitance and avoid pile up in high-dose rate pencil beam scanning applications. Detailed TCAD simulations and charge collection studies in individual SVs have been performed. The microdosimetry probe (MicroPlus) is composed of the silicon microdosimeter and low-noise front–end readout electronics housed in a PMMA waterproof sheath that allows measurements of lineal energies as low as 0.4 keV/µm in water or PMMA. Microdosimetric quantities measured with SOI microdosimeters and the MicroPlus probe were used to evaluate the relative biological effectiveness (RBE) of heavy ions and protons delivered by pencil-beam scanning and passive scattering systems in different particle therapy centres. The 3D detectors and MicroPlus probe developed for microdosimetry have the potential to provide confidence in the delivery of RBE optimized particle therapy when introduced into routine clinical practice. Full article
(This article belongs to the Special Issue Detectors for Medical Physics)
Show Figures

Figure 1

46 pages, 17075 KB  
Review
Evolution of Heavy Ion Beam Probing from the Origins to Study of Symmetric Structures in Fusion Plasmas
by Alexander Melnikov
Symmetry 2021, 13(8), 1367; https://doi.org/10.3390/sym13081367 - 27 Jul 2021
Cited by 9 | Viewed by 4388
Abstract
The overview discusses development of the unique fusion plasma diagnostics—Heavy Ion Beam Probing (HIBP) in application to toroidal magnetic plasma devices. The basis of the HIBP measurements of the plasma electric potential and processing of experimental data are considered. Diagnostic systems for probing [...] Read more.
The overview discusses development of the unique fusion plasma diagnostics—Heavy Ion Beam Probing (HIBP) in application to toroidal magnetic plasma devices. The basis of the HIBP measurements of the plasma electric potential and processing of experimental data are considered. Diagnostic systems for probing plasma in tokamaks TM-4, TJ-1, TUMAN-3M and T-10, stellarators WEGA, TJ-II and Uragan-2M are presented. Promising results of the HIBP projects for various existing modern machines, such as TCV, TCABR, MAST, COMPASS, GLOBUS-M2, T-15 MD and W7-X and the international fusion tokamak reactor ITER are given. Results from two machines with similar size and plasma parameters, but with different types of the magnetic con-figuration: axisymmetric tokamak T-10 and helically symmetric stellarator TJ-II are compared. The results of studies of stationary potential profiles and oscillations in the form of quasimonochromatic and broadband fluctuations, turbulent particle flux, fluctuations of density and poloidal magnetic field are presented. The properties of symmetric structures—zonal flows and geodesic acoustic modes of plasma oscillations as well as Alfvén Eigenmodes excited by fast particles from neutral beam injection heating are described. General trends in the behavior of electric potential and turbulence in magnetized fusion plasmas are revealed. Full article
(This article belongs to the Special Issue Symmetry in Physics of Plasma Technologies)
Show Figures

Figure 1

10 pages, 2864 KB  
Article
Upgrading the Baryonic Matter at the Nuclotron Experiment at NICA for Studies of Dense Nuclear Matter
by Peter Senger, Dmitrii Dementev, Johann Heuser, Mikhail Kapishin, Evgeny Lavrik, Yuri Murin, Anna Maksymchuk, Hans Rudolf Schmidt, Christian Schmidt, Anna Senger and Alexander Zinchenko
Particles 2019, 2(4), 481-490; https://doi.org/10.3390/particles2040029 - 15 Nov 2019
Cited by 24 | Viewed by 4127
Abstract
The Nuclotron at the Joint Institute for Nuclear Research in Dubna can deliver gold beams with kinetic energies between 2 and 4.5 A GeV. In heavy-ion collisions at these energies, it is expected that the nuclear fireball will be compressed by up to [...] Read more.
The Nuclotron at the Joint Institute for Nuclear Research in Dubna can deliver gold beams with kinetic energies between 2 and 4.5 A GeV. In heavy-ion collisions at these energies, it is expected that the nuclear fireball will be compressed by up to approximately four times the saturation density. This offers the opportunity to study the high-density equation-of-state (EOS) of nuclear matter in the laboratory, which is needed for our understanding of the structure of neutron stars and the dynamics of neutron star mergers. The Baryonic Matter at the Nuclotron (BM@N) experiment will be upgraded to perform multi-differential measurements of hadrons including (multi-) strange hyperons, which are promising probes of the high-density EOS, and of new phases of quantum chromodynamic (QCD) matter. The layout of the upgraded BM@N experiment and the results of feasibility studies are presented. Full article
Show Figures

Graphical abstract

4 pages, 1208 KB  
Proceeding Paper
Direct Photons at the PHENIX Experiment: From Large to Small Systems
by Veronica Canoa Roman
Proceedings 2019, 10(1), 32; https://doi.org/10.3390/proceedings2019010032 - 17 Apr 2019
Cited by 3 | Viewed by 1940
Abstract
Direct photons are a unique probe to study the properties of the medium created in heavy ion collisions. Low transverse momentum ( p T ) direct photons are of special interest since thermal photons are supposed to be dominant, while at high [...] Read more.
Direct photons are a unique probe to study the properties of the medium created in heavy ion collisions. Low transverse momentum ( p T ) direct photons are of special interest since thermal photons are supposed to be dominant, while at high p T direct photons come from initial hard scattering (pQCD). PHENIX has observed a large excess of direct photon yield as well as large azimuthal anisotropy at low p T in Au+Au collisions at the c.m.s energy per nucleon pair s N N = 200 GeV. The mechanism to produce a large direct photon yield with a large elliptic anisotropy ( v 2 ) is not well understood yet. PHENIX has made systematic measurements of direct photons with different collision energies and system configurations. It has been found that direct photon yield d N γ / d η is proportional to charge particle multiplicity ( d N c h / d η ) 1 . 25 . This behavior holds for beam energies measured both at RHIC and at the LHC in large systems. This scaling suggests that there is a transition from p+p to A+A system which could be understood with the analysis of smaller systems like p+Au and d+Au. Full article
Show Figures

Figure 1

Back to TopTop