31 pages, 2892 KB  
Article
Multi-Time-Scale Secure and Economic Dispatch of Active Distribution Networks Integrating Converter Operating Characteristic Constraints
by Ke Liu, Jun Han, Wenqian Zhang, Rui Song, Shiao Wang and Nan Yang
Electronics 2026, 15(14), 3021; https://doi.org/10.3390/electronics15143021 - 9 Jul 2026
Viewed by 395
Abstract
The increasing penetration of renewable energy in active distribution networks introduces severe power fluctuations and uncertainties. This challenges traditional scheduling methods that rely on conservative and static capacity boundaries of converter-interfaced equipment. This paper proposes a multi-time-scale secure and economic dispatch framework that [...] Read more.
The increasing penetration of renewable energy in active distribution networks introduces severe power fluctuations and uncertainties. This challenges traditional scheduling methods that rely on conservative and static capacity boundaries of converter-interfaced equipment. This paper proposes a multi-time-scale secure and economic dispatch framework that explicitly integrates the dynamic operating characteristic constraints of grid-forming converters. First, a spatial correlation model based on Copula theory is established to handle wind power uncertainties via scenario generation and reduction for the day-ahead and intra-day scheduling phases. This formulation aims to minimize the comprehensive operational costs of the system. For the real-time rolling optimization phase, the short-term overload potential of grid-forming converters, which is unlocked by electro-thermal coupling optimization and discontinuous pulse width modulation phase-shift clamping, is mathematically abstracted into a generalized dynamic elliptical active and reactive power capability envelope. This cross-scale mapping mechanism allows the system to utilize transient thermal margins for enhanced local reactive power support without violating device junction temperature limits. Furthermore, the non-convex scheduling model is transformed into a mixed-integer second-order cone programming problem using convex relaxation techniques to guarantee global optimality and computational efficiency. Comprehensive case studies on the modified IEEE 33-bus and 69-bus systems demonstrate that the proposed strategy reduces tie-line power fluctuations and operational costs under extreme conditions. The results achieve a favorable economic trade-off between brief power quality degradation and global physical stability. Full article
(This article belongs to the Section Power Electronics)
Show Figures

Figure 1

30 pages, 8022 KB  
Article
Intelligent ANN-Based Controller for Decentralized Power Grids’ Load Frequency Control
by Rambaboo Singh, Ramesh Kumar, Ravi Shankar and Rakesh Kumar Singh
Processes 2025, 13(11), 3562; https://doi.org/10.3390/pr13113562 - 5 Nov 2025
Cited by 1 | Viewed by 931
Abstract
In this study, the authors demonstrate the development and evaluation of an optimal frequency control controller for an interlinked two-area power system that incorporates Renewable Energy Sources (RESs). In decentralized power grids, the Load Frequency Control (LFC) system allows scheduled tie-line power as [...] Read more.
In this study, the authors demonstrate the development and evaluation of an optimal frequency control controller for an interlinked two-area power system that incorporates Renewable Energy Sources (RESs). In decentralized power grids, the Load Frequency Control (LFC) system allows scheduled tie-line power as well as system frequency to be reimposed to their nominal values. Designing an advanced controller might enhance the functionality of the LFC mechanism. This article illustrates the possible impacts of converter capacitors using the new High-Voltage Direct Current (HVDC) tie-line model as well as the Inertia Emulation Technique (IET). This paper suggests a new adaptive control procedure for the expected LFC mechanism: an ANN-based (PIλ + PIλf) controller. The authors evaluate which control parameters are most effective using a modified version of the Quasi-Opposition-learning-based Reptile Search Algorithm (QORSA) method. Software called MATLAB/Simulink-2015 is used to create this arrangement. The use of established techniques for handling step as well as random load disturbances has enabled an evaluation of the suggested LFC architecture’s efficacy. An IET-based HVDC tie-line reduces overshoot by 100% in Areas 1 and 2 (Area 1 frequency deviation, i.e., ∆f1, as well as Area 2 frequency deviation, i.e., ∆f2). When considering SLD, the suggested controller outperforms the most widely used alternative settings. The IEEE-39 bus system has been changed by the addition of RESs. The IEEE-39 bus system is composed of three control areas. It is confirmed how the IEEE-39 bus system reacts to changes in frequency in Areas 1, 2, and 3. It is illustrated how to use the suggested controller in the modified IEEE-39 bus system, accompanied by real-time load variations. Recent research indicates that the suggested control method is better and more efficient due to its 100% decrease in overshoot in Areas 1 and 2 and quick response time. Full article
Show Figures

Figure 1

21 pages, 3404 KB  
Article
Stability Analysis of a Receiving-End VSC-HVDC System with Parallel-Connected VSCs
by Zijun Bin, Xiangping Kong, Kai Zhao, Xi Wu, Yubo Yuan and Xuchao Ren
Electronics 2025, 14(11), 2178; https://doi.org/10.3390/electronics14112178 - 27 May 2025
Cited by 2 | Viewed by 2476
Abstract
Voltage source converter-based high-voltage direct current (VSC-HVDC) systems integrated into weak AC grids may exhibit oscillation-induced instability, posing significant threats to power system security. With increasing structural complexity and diverse control strategies, the stability characteristics of VSC-HVDC system require further investigation. This paper [...] Read more.
Voltage source converter-based high-voltage direct current (VSC-HVDC) systems integrated into weak AC grids may exhibit oscillation-induced instability, posing significant threats to power system security. With increasing structural complexity and diverse control strategies, the stability characteristics of VSC-HVDC system require further investigation. This paper focuses on the stability of a receiving-end VSC-HVDC system consisting of a DC voltage-controlled VSC parallel-connected to a power-controlled VSC, under various operating conditions. First, small-signal models of each subsystem were developed and a linearized full-system model was constructed based on port relationships. Then, eigenvalue and participation factor analyses were utilized to evaluate the influence of control strategy, asymmetrical grid strength, power flow direction, and tie line on the system’s small-signal stability. A feasible short-circuit ratio (SCR) region was established based on joint power–topology joint, forming a stable operating space for the system. Finally, the correctness of the theoretical analysis was validated via MATLAB/Simulink time-domain simulations. Results indicate that, in comparison to the power control strategy, the DC voltage control strategy was more sensitive to variations in the AC system and demands a strong grid, and this disparity was predominantly caused by the DC voltage control. Furthermore, the feasible region of the short-circuit ratio (SCR) diminished with the increase in the length of the tie-line and alterations in power flow direction under the mutual-support power mode, leading to a gradual reduction in the system’s stability margin. Full article
Show Figures

Figure 1

17 pages, 9193 KB  
Article
Hybrid ANPC Grid-Tied Inverter Design with Passivity-Based Sliding Mode Control Strategy
by Yifei Zhang, Kang Li and Li Zhang
Energies 2024, 17(15), 3655; https://doi.org/10.3390/en17153655 - 25 Jul 2024
Cited by 8 | Viewed by 2627
Abstract
Voltage source inverters are extensively used in the grid connection of renewable energy-sourced generators, and multilevel converters, in particular, have attracted a great deal of attention in recent years. This paper investigates the application of a novel passivity-based sliding mode (PSM) control scheme [...] Read more.
Voltage source inverters are extensively used in the grid connection of renewable energy-sourced generators, and multilevel converters, in particular, have attracted a great deal of attention in recent years. This paper investigates the application of a novel passivity-based sliding mode (PSM) control scheme on three-level grid-tie active Neutral-Point-Clamped (ANPC) inverters that yield fast and stable responses to grid impedance variations. Simulation studies confirm that this control scheme can produce high tracking performance and is also robust against grid load variations. Furthermore, to enhance ANPC efficiency, the loss distribution of switching devices controlled by the proposed strategy is evaluated. An optimal scheme is finally proposed for allocating silicon and Wide-Band-Gap switching devices, resulting in a hybrid ANPC inverter capable of achieving a desirable trade-off between the power losses and the device cost. Full article
(This article belongs to the Special Issue Energy, Electrical and Power Engineering 2024)
Show Figures

Figure 1

24 pages, 10820 KB  
Article
Hybrid Wind-Solar Power System with a Battery-Assisted Quasi-Z-Source Inverter: Optimal Power Generation by Deploying Minimum Sensors
by Matija Bubalo, Mateo Bašić, Dinko Vukadinović and Ivan Grgić
Energies 2023, 16(3), 1488; https://doi.org/10.3390/en16031488 - 2 Feb 2023
Cited by 14 | Viewed by 3118
Abstract
This paper presents a hybrid renewable energy system (RES) including wind and photovoltaic (PV) power sources. The wind energy subsystem (WES) consists of a squirrel-cage induction generator (SCIG) driven by a variable-speed wind turbine (WT) and corresponding power electronic converter, by means of [...] Read more.
This paper presents a hybrid renewable energy system (RES) including wind and photovoltaic (PV) power sources. The wind energy subsystem (WES) consists of a squirrel-cage induction generator (SCIG) driven by a variable-speed wind turbine (WT) and corresponding power electronic converter, by means of which a speed-sensorless indirect-rotor-field-oriented control of the SCIG is implemented. The outputs of both the WES and PV power source rated 1.5 kW and 3.5 kW, respectively, are connected to the DC bus, with the quasi-Z-source inverter (qZSI) acting as an interlinking converter between the DC bus and the AC grid/load. An advanced pulse-width-modulation scheme is applied to reduce the qZSI switching losses. The considered RES can operate both in grid-tie and island operation, whereas the battery storage system—integrated within the qZSI impedance network—enables more efficient energy management. The proposed control scheme includes successively executed algorithms for the optimization of the WES and PV power outputs under varying atmospheric conditions. A perturb-and-observe PV optimization algorithm is executed first due to the significantly faster dynamics and higher-rated power of the PV source compared to the WES. The WES optimization algorithm includes two distinct fuzzy logic optimizations: one for extraction of the maximum wind power and the other for minimization of the SCIG losses. To reduce the number of the required sensors, all three MPPT algorithms utilize the same input variable—the qZSI’s input power—thus increasing the system’s reliability and reducing the cost of implementation. The performance of the proposed hybrid RES was experimentally evaluated over wide ranges of simulated atmospheric conditions in both the island and grid-tie operation. Full article
(This article belongs to the Special Issue Power Converter Control Applications in Low-Inertia Power Systems)
Show Figures

Figure 1

23 pages, 17392 KB  
Article
Design and Implementation of a SiC-Based VRFB Power Conditioning System
by Chao-Tsung Ma and Yi-Hung Tian
Micromachines 2020, 11(12), 1099; https://doi.org/10.3390/mi11121099 - 12 Dec 2020
Cited by 3 | Viewed by 3130
Abstract
An energy storage system using secondary batteries combined with advanced power control schemes is considered the key technology for the sustainable development of renewable energy-based power generation and smart micro-grids. The performance of energy storage systems in practical application mainly depends on their [...] Read more.
An energy storage system using secondary batteries combined with advanced power control schemes is considered the key technology for the sustainable development of renewable energy-based power generation and smart micro-grids. The performance of energy storage systems in practical application mainly depends on their power conditioning systems. This paper proposes a silicon carbide-based multifunctional power conditioning system for the vanadium redox flow battery. The proposed system is a two-stage circuit topology, including a three-phase grid-tie inverter that can perform four-quadrant control of active and reactive power and a bi-directional multi-channel direct current converter that is responsible for the fast charging and discharging control of the battery. To achieve the design objectives, i.e., high reliability, high efficiency, and high operational flexibility, silicon carbide-based switching devices, and advanced digital control schemes are used in the construction of a power conditioning system for the vanadium redox flow battery. This paper first describes the proposed system topologies and controller configurations and the design methods of controllers for each converter in detail, and then results from both simulation analyses and experimental tests on a 5 kVA hardware prototype are presented to verify the feasibility and effectiveness of the proposed system and the designed controllers. Full article
Show Figures

Figure 1

15 pages, 5132 KB  
Article
Power Supply Solution for Ultrahigh Speed Hyperloop Trains
by Marcos Lafoz, Gustavo Navarro, Jorge Torres, Álvaro Santiago, Jorge Nájera, Miguel Santos-Herran and Marcos Blanco
Smart Cities 2020, 3(3), 642-656; https://doi.org/10.3390/smartcities3030033 - 9 Jul 2020
Cited by 17 | Viewed by 8620
Abstract
The paper analyses the alternatives for the power supply of a Hyperloop type railway transport. The particular case of the technology of the Spanish company ZELEROS was studied. Based on previous technical specifications related to both the first prototype and a commercial system, [...] Read more.
The paper analyses the alternatives for the power supply of a Hyperloop type railway transport. The particular case of the technology of the Spanish company ZELEROS was studied. Based on previous technical specifications related to both the first prototype and a commercial system, different options were analyzed. We selected the use of a linear motor driven by a single power electronic converter, a distribution scheme comprising different sections along the acceleration area of the track, and an energy storage system based on supercapacitors for the energy supply. The power/energy ratio and the cycle capability are the reasons to become a feasible and competitive solution. A preliminary design methodology for the energy storage requirements is presented in the paper. Once the type of linear motor was selected, the power supply scheme was presented, based on a motor-side power electronic converter and a DC/DC converter which connects to the energy storage devices. An additional low power grid-tie converter for the recharge of the energy storage system was also used. Different track sections were defined, connected to the power electronic converter through corresponding switches, being supplied sequentially when the capsule presence is detected along the track. The particular characteristics of this application, with relatively short traction track area, as well as the high energy recuperation ratio due to the low losses, make more suitable the use of energy storage systems as the source of power supply than the direct connection to the grid. Full article
(This article belongs to the Special Issue Mobility and IoT for the Smart Cities)
Show Figures

Graphical abstract

14 pages, 1967 KB  
Article
AC Tie-Line Power Oscillation Mechanism and Peak Value Calculation for a Two-Area AC/DC Parallel Interconnected Power System Caused by LCC-HVDC Commutation Failures
by Li Sun, Hongbo Liu and Chenglian Ma
Energies 2020, 13(5), 1221; https://doi.org/10.3390/en13051221 - 6 Mar 2020
Cited by 5 | Viewed by 3318
Abstract
With the rapid development of ultra-high-voltage (UHV) AC/DC, especially the step-by-step upgrading of the UHV DC transmission scale, security presents new challenges. Commutation failure (CF) is a common fault in line commutated converter (LCC) high-voltage direct current (HVDC) power systems. Once failure happens, [...] Read more.
With the rapid development of ultra-high-voltage (UHV) AC/DC, especially the step-by-step upgrading of the UHV DC transmission scale, security presents new challenges. Commutation failure (CF) is a common fault in line commutated converter (LCC) high-voltage direct current (HVDC) power systems. Once failure happens, it may cause power oscillations in a system. In this paper, taking a two-area AC/DC parallel interconnected power system as the example, based on the impulse response model of second-order linear system, the mechanism of power oscillation on the AC tie-line caused by CF are clarified. It is proved that the peak value of the AC tie-line power oscillation is mainly determined by the DC power and the equivalent CF duration, the frequency and damping ratio of dominant area oscillation mode. Meanwhile, the peak time is mainly determined by the oscillation frequency. Finally, the correctness and effectiveness of the algorithms are verified by a simulation analysis of an extended IEEE-39-bus AC/DC parallel interconnected power system. These research results can provide a basis for the arrangement of the operating modes and the formulation of control measures for interconnected power grids. Full article
Show Figures

Graphical abstract

18 pages, 6393 KB  
Article
High Efficiency Solar Power Generation with Improved Discontinuous Pulse Width Modulation (DPWM) Overmodulation Algorithms
by Lan Li, Hao Wang, Xiangping Chen, Abid Ali Shah Bukhari, Wenping Cao, Lun Chai and Bing Li
Energies 2019, 12(9), 1765; https://doi.org/10.3390/en12091765 - 9 May 2019
Cited by 10 | Viewed by 5063
Abstract
The efficiency of a photovoltaic (PV) system strongly depends on the transformation process from solar energy to electricity, where maximum power point tracking (MPPT) is widely regarded as a promising technology to harvest solar energy in the first step. Furthermore, inverters are an [...] Read more.
The efficiency of a photovoltaic (PV) system strongly depends on the transformation process from solar energy to electricity, where maximum power point tracking (MPPT) is widely regarded as a promising technology to harvest solar energy in the first step. Furthermore, inverters are an essential part of solar power generation systems. Their performance dictates the power yield, system costs and reliable operation. This paper proposes a novel control technology combining discontinuous pulse width modulation (DPWM) and overmodulation technology to better utilize direct current (DC) electrical power and to reduce the switching losses in the electronic power devices in conversion. In order to optimize the performance of the PV inverter, the overmodulation region is refined from conventional two-level space vector pulse width modulation (SVPWM) control technology. Then, the turn-on and turn-off times of the switching devices in different modulation areas are deduced analytically. A new DPWM algorithm is proposed to achieve the full region control. An experimental platform based on a digital signal processing (DSP) controller is developed for validation purposes, after maximum power is achieved via a DC/DC converter under MPPT operation. Experimental results on a PV system show that the DPWM control algorithm lowers the harmonic distortion of the output voltage and current, as well as the switching losses. Moreover, better utilization of the DC-link voltage also improves the PV inverter performance. The developed algorithm may also be applied to other applications utilizing grid-tie power inverters. Full article
(This article belongs to the Special Issue Design and Control of Power Converters 2019)
Show Figures

Figure 1

14 pages, 3465 KB  
Article
Smart Integration of a DC Microgrid: Enhancing the Power Quality Management of the Neighborhood Low-Voltage Distribution Network
by Ahmed F. Ebrahim, Ahmed A. Saad and Osama Mohammed
Inventions 2019, 4(2), 25; https://doi.org/10.3390/inventions4020025 - 17 Apr 2019
Cited by 4 | Viewed by 6946
Abstract
The fast development of the residential sector regarding the additional integration of renewable distributed energy sources and the modern expansion usage of essential DC electrical equipment may cause severe power quality problems. For example, the integration of rooftop photovoltaic (PV) may cause unbalance, [...] Read more.
The fast development of the residential sector regarding the additional integration of renewable distributed energy sources and the modern expansion usage of essential DC electrical equipment may cause severe power quality problems. For example, the integration of rooftop photovoltaic (PV) may cause unbalance, and voltage fluctuation, which can add constraints for further PV integrations to the network, and the deployment of DC native loads with their nonlinear behavior adds harmonics to the network. This paper demonstrates the smart integration of a DC microgrid to the neighborhood low-voltage distribution network (NLVDN). The DC microgrid is connected to the NLVDN through a three-phase voltage source inverter (VSI), in which the VSI works as a distribution static compensator (DSTATCOM). Unlike previous STATCOM work in the literature, the proposed controller of the VSI of the DC smart building allows for many functions: (a) it enables bidirectional active/reactive power flow between the DC building and the AC grid at point of common coupling (PCC); (b) it compensates for the legacy unbalance in the distribution network, providing harmonics elimination and power factor correction capability at PCC; and (c) it provides voltage support at PCC. The proposed controller was validated by Matlab/Simulink and by experimental implementation at the lab. Full article
Show Figures