Sign in to use this feature.

Years

Between: -

Subjects

remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline

Journals

Article Types

Countries / Regions

Search Results (58)

Search Parameters:
Keywords = grade 10.9 bolt

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
28 pages, 5472 KB  
Article
Experimental and Finite Element Study on the Seismic Performance of Reinforced New-Type Joints: Adding Beams to Existing Columns
by Jian Wu, Shi’en Zhang, Changhao Wei, Yifei Tao, Chunjuan Zhou, Yuxi Wang and Yuchun Li
Buildings 2026, 16(13), 2504; https://doi.org/10.3390/buildings16132504 (registering DOI) - 24 Jun 2026
Abstract
Currently, the development of civil engineering industry is gradually slowing down, with the focus gradually shifting toward the reinforcement and renovation of existing buildings. Among these existing structures, reinforced concrete (RC) structure is a kind of structure with high proportion. Therefore, this paper [...] Read more.
Currently, the development of civil engineering industry is gradually slowing down, with the focus gradually shifting toward the reinforcement and renovation of existing buildings. Among these existing structures, reinforced concrete (RC) structure is a kind of structure with high proportion. Therefore, this paper conducts research on the seismic properties of RC buildings after adding new beams to existing columns. This paper first introduces the design situation of the specimen, followed by an experimental investigation of its mechanical properties using pseudo-static tests. Based on the failure patterns and hysteresis curves, the differences between the new-type specimen and RC specimen are analyzed. The findings indicate that, while ensuring load-bearing capacity, the new-type joints exhibit better seismic performance: the bearing capacity and maximum displacement are increased by at most 9.2% and 14.9% respectively, and the fuller hysteresis curve shows that the new-type specimen has better energy dissipation capacity. Finally, this paper extends the analysis of the design parameters of the specimens using finite element components. The modeling results reveal that the bearing capacity varies by less than 1% with different parameters such as connector thickness, concrete strength grade, and bolts quantity and strength, indicating that these parameters have a relatively small impact on the bearing capacity. While for the specimen dimensions and thickness and strength of wrapped steel of beam, the maximum increase in bearing capacity is 32.3% and 6.0%, respectively. Indicating that their impact is quite significant. The findings of this paper provide a reference for structural design and contribute to advancing the work of reinforcement and renovation of existing concrete structures. Full article
20 pages, 8040 KB  
Article
Response Characteristics and Adaptability Analysis of the Benching Method in Grade IV and V Surrounding Rocks in Sandstone–Mudstone Strata
by Liang Luo and Yuchao Zheng
Buildings 2026, 16(10), 1901; https://doi.org/10.3390/buildings16101901 - 11 May 2026
Viewed by 327
Abstract
To improve construction efficiency for large-section tunnels in sandstone–mudstone strata, this study investigates the applicability of the two-bench method and the three-bench method for grade IV and grade V surrounding rock, respectively. Based on FLAC3D, numerical simulations of excavation and support for the [...] Read more.
To improve construction efficiency for large-section tunnels in sandstone–mudstone strata, this study investigates the applicability of the two-bench method and the three-bench method for grade IV and grade V surrounding rock, respectively. Based on FLAC3D, numerical simulations of excavation and support for the two benching methods were conducted to analyze deformation responses, including ground settlement, crown settlement, haunch convergence, floor uplift, and face extrusion. The simulation results were then compared and validated against field monitoring data to evaluate the applicability and feasibility of the construction methods. The results show that, for grade IV surrounding rock excavated using the two-bench method, crown settlement, floor uplift, and horizontal convergence converge and stabilize on days 17, 15, and 25, with stable values of 14.0 mm, 10.3 mm, and 13.2 mm, respectively. For grade V surrounding rock excavated using the three-bench method, these indices stabilize on days 24, 22, and 32, with stable values of 26.3 mm, 20.3 mm, and 20.8 mm, respectively. The surrounding rock pressures at the crown and spandrel gradually attenuate after excavation and stabilize at 1–4 MPa after approximately 20–26 days, whereas stress release at the haunch lasts longer and the stabilized stress level remains higher. Meanwhile, the anchor bolt axial force at the haunch is significantly greater than that at the spandrel, indicating that the haunch is a critical zone for support load-bearing and deformation control. The benching method can effectively control surrounding rock deformation under grade IV and V surrounding rock conditions in sandstone–mudstone strata; however, in engineering practice, the haunch should be treated as a key monitoring target, and targeted support and reinforcement measures should be implemented. Full article
(This article belongs to the Section Building Structures)
Show Figures

Figure 1

21 pages, 3907 KB  
Article
Finite Element Analysis of Seismic Performance of Semi-Rigid Steel Frame Equipped with a New Composite Shear Wall
by Jieyu Song, Zhenyuan Gu, Lu Feng, Shijie Xu, Ying Sun and Wangping Qian
Buildings 2026, 16(6), 1193; https://doi.org/10.3390/buildings16061193 - 18 Mar 2026
Viewed by 359
Abstract
The steel frame-shear wall composite system has excellent lateral resistance performance in prefabricated steel structure buildings. However, the traditional steel plate concrete shear wall is prone to early buckling of the steel plate and concentrated interface damage under cyclic loading, which limits its [...] Read more.
The steel frame-shear wall composite system has excellent lateral resistance performance in prefabricated steel structure buildings. However, the traditional steel plate concrete shear wall is prone to early buckling of the steel plate and concentrated interface damage under cyclic loading, which limits its energy dissipation capacity. This study presents a steel plate-enhanced reinforced concrete shear wall (SPRCSW) with an internal corrugated steel plate and double-layer steel mesh working together and conducts a selection study based on finite element analysis. Under the same design conditions, the peak bearing capacity in the positive and reverse directions of the SPRCSW is increased by approximately 55.4% and 46.9%, respectively, compared to the ordinary reinforced concrete shear wall, with a ductility coefficient reaching 6.08. The stiffness decline is mild, and the hysteretic curve is complete. Then, this paper forms an SR-SPRCSW composite structural system by combining the new shear wall with a steel frame using semi-rigid joints. Through the comparison of the finite element analysis and low-cycle reverse loading test results of the SR-SPRCSW structure, it is verified that the overall structural system shows good agreement in hysteretic response, skeleton curve characteristics, and failure mode under both research methods, with the peak shear bearing capacity error of less than 1% and the overall bearing capacity deviation controlled within 8%. On this basis, the key parameters of the semi-rigid joints in the SR-SPRCSW structure are analyzed. The results show that the strengthening of the “top and bottom + double web” angle steel joint can raise the peak bearing capacity of the SR-SPRCSW structure by approximately 26.1% and the yield displacement by approximately 29.5%; increasing the strength grade and diameter of high-strength bolts can heighten the initial stiffness and bearing capacity of the overall structure, but ductility slightly decreases; the thickness of the angle steel has a significant impact on the stiffness and deformation capacity of the structure, and a recommended range of values with better comprehensive performance is provided. The findings offer valuable insights for designing seismic-resistant semi-rigid steel frames with steel plate reinforced concrete shear walls and optimizing their parameters. Full article
(This article belongs to the Section Building Structures)
Show Figures

Figure 1

32 pages, 9312 KB  
Article
Push-Out Testing of Demountable Bolted Shear Connection in Composite Cold-Formed Steel Beams: Experimental Evaluation and Analysis
by Vlaho Žuvelek, Ivan Ćurković, Ivan Lukačević, Andrea Rajić and Marko Bartolac
Buildings 2026, 16(5), 979; https://doi.org/10.3390/buildings16050979 - 2 Mar 2026
Viewed by 512
Abstract
The Innovative Lightweight Cold-Formed Steel–Concrete Composite Floor System (LWT-FLOOR) addresses key challenges faced by the construction industry related to the efficiency, adaptability, and life-cycle usability of structural elements. Within this context, the present study investigated the behaviour of demountable bolted shear connections in [...] Read more.
The Innovative Lightweight Cold-Formed Steel–Concrete Composite Floor System (LWT-FLOOR) addresses key challenges faced by the construction industry related to the efficiency, adaptability, and life-cycle usability of structural elements. Within this context, the present study investigated the behaviour of demountable bolted shear connections in a composite system combining built-up cold-formed steel (CFS) girders and concrete slabs. An experimental programme comprising 18 push-out tests was conducted on two composite configurations: built-up back-to-back CFS sections and built-up sections incorporating a corrugated web. The influence of key parameters, including the bolt diameter, CFS thickness, steel grade, and connector spacing, was evaluated. The results show that increasing the bolt diameter enhanced the shear resistance and initial stiffness while reducing ductility, whereas reducing the CFS thickness led to a moderate decrease in resistance accompanied by a pronounced increase in ductility. The incorporation of a corrugated web increased the ultimate shear resistance by approximately 30–40%. The existing analytical models from current standards were found to be inadequate; however, the introduction of a spacing-dependent correction factor into the prEN 1994-1-1 model significantly improved the prediction accuracy, reducing the coefficient of variation from 16% to 4.36%. The findings provide a quantitative basis for improving the design of demountable shear connections in lightweight composite CFS-concrete systems. Full article
Show Figures

Figure 1

16 pages, 3795 KB  
Article
Model Experimental Study on a Rapidly Assembled Lattice Beam Support Structure
by Jiong Liang, Yuntao Zhou, Ruiming Zhang, Zilong Li, Yang Liu and Wentao Wang
Buildings 2026, 16(4), 766; https://doi.org/10.3390/buildings16040766 - 13 Feb 2026
Viewed by 545
Abstract
In order to investigate the mechanical properties and supporting effect of the rapidly assembled lattice beam supporting structure in slope engineering, an indoor physical model test based on a scale ratio of 1:2 was carried out to simulate the typical landslide geological conditions [...] Read more.
In order to investigate the mechanical properties and supporting effect of the rapidly assembled lattice beam supporting structure in slope engineering, an indoor physical model test based on a scale ratio of 1:2 was carried out to simulate the typical landslide geological conditions of a highway slope. The structural design, construction technology and mechanical response characteristics of the assembled lattice beam under different loads were systematically studied. The stress process of the slope was simulated by the graded vertical loading method, and the evolution law of the soil pressure at each measuring point of the lattice beam cross beam and vertical beam was monitored. The test results show that the assembled lattice beam does not significantly participate in the load transfer of the soil at the initial loading stage. As the load gradually increases, its load-bearing capacity is significantly improved, and the supporting effect is obvious. The earth pressure of the cross beam is non-uniformly distributed along the length direction, and the force near the node and the edge area is significantly higher than that in the mid-span position. The earth pressure of the vertical beam shows a decreasing trend along the height direction, which reveals its transfer law to the concentrated load. The test results can provide a theoretical basis and experimental reference for the design and optimization of a bolt-fabricated lattice beam structure under complex geological conditions. Full article
Show Figures

Figure 1

22 pages, 2341 KB  
Article
Quantitative Detection of High-Strength Bolt Loosening Based on Self-Magnetic Flux Leakage
by Shangkai Liu, Kai Tong, Fengmin Chen, Senhua Zhang and Runchan Xia
Buildings 2026, 16(3), 497; https://doi.org/10.3390/buildings16030497 - 26 Jan 2026
Viewed by 626
Abstract
The reliability of high-strength bolted connections is critical to the safety of large-scale engineering structures. This study proposes a non-contact quantitative method for detecting bolt loosening based on the self-magnetic flux leakage (SMFL) effect. Systematic experiments were carried out on M14-12.9 bolts, using [...] Read more.
The reliability of high-strength bolted connections is critical to the safety of large-scale engineering structures. This study proposes a non-contact quantitative method for detecting bolt loosening based on the self-magnetic flux leakage (SMFL) effect. Systematic experiments were carried out on M14-12.9 bolts, using nine independent specimens tested under six torque levels, to reveal the intrinsic relationship between bolt preload and the “magnetic valley” feature of the surface leakage field. For quantitative evaluation, the absolute value of the differential peak magnetic field, |ΔPMF|, is defined as the core feature parameter. The results show that, in the reference specimen group, |ΔPMF| exhibits a pronounced linear relationship with the applied torque (R2 > 0.96), and the corresponding linear regression parameters display good consistency across the nine specimens (RSD ≈ 4%). Comparative tests on two additional bolt specifications clarify how bolt strength grade and geometric size influence the detection sensitivity and linearity. To address lift-off effects, measurements on a representative specimen at four lift-off heights were used to construct a simplified bivariate linear compensation model, which significantly reduces lift-off-induced bias within the working range h = 10–16 mm. Finally, a hierarchical diagnostic scheme for bolt loosening that incorporates lift-off compensation is established on the basis of |ΔPMF|, providing a feasible approach for rapid assessment of bolt loosening under complex service conditions. Full article
Show Figures

Figure 1

28 pages, 5849 KB  
Article
A New Modified CDP Constitutive Model for Jute Fiber-Reinforced Recycled Aggregate Concrete and Its Sustainable Application in Precast Cable Trench Joints
by Luying Ju, Jianfeng Zhu, Weijun Zhong, Mingfang Ba, Kai Shu, Xinying Fang, Jiayu Jin and Yucheng Zou
Sustainability 2026, 18(2), 707; https://doi.org/10.3390/su18020707 - 9 Jan 2026
Cited by 1 | Viewed by 560
Abstract
To address the dual challenges of improving precast cable trench joint performance and promoting solid waste recycling for carbon neutrality, this study developed a jute fiber-reinforced recycled aggregate concrete (JFRAC) and established a complete technical chain via experiments and numerical simulations. Compressive strength [...] Read more.
To address the dual challenges of improving precast cable trench joint performance and promoting solid waste recycling for carbon neutrality, this study developed a jute fiber-reinforced recycled aggregate concrete (JFRAC) and established a complete technical chain via experiments and numerical simulations. Compressive strength tests were conducted on JFRAC with varying jute fiber volume content and recycled coarse aggregate (RCA) replacement ratio to obtain their influence on the stress–strain relationship. A modified Concrete Damaged Plasticity (CDP) model was proposed by introducing correction coefficients for compressive strength and elastic modulus, achieving over 95% agreement with experimental data. Finite element simulations of cable trench joints showed that JFRAC outperforms C30 concrete, with the same compressive strength, in ultimate bearing capacity (↑4.17%), peak displacement (↑18.78%), and ductility (↑14.66%). JFRAC provides substantial environmental and economic advantages by reducing carbon emissions by 2.29% and saving costs of CNY 62.43 per meter of precast cable trench. Parametric studies indicated bolt grade and number are the primary performance influencers. Bolt grade’s impact diminishes as it increases from 8.8 to 10.9, while bolt number linearly enhances load-bearing capacity. This study provides a feasible path for JFRAC to replace conventional concrete in cable trenches, realizing both economic and environmental benefits. Full article
(This article belongs to the Section Green Building)
Show Figures

Figure 1

20 pages, 4061 KB  
Article
A Moment-Rotation Model of Semi-Rigid Steel Structure Joints with Bolted Connection
by Mengxin Kang, Shifeng Hou, Juyang Cai and Liang Zhang
Buildings 2026, 16(1), 182; https://doi.org/10.3390/buildings16010182 - 1 Jan 2026
Cited by 1 | Viewed by 738
Abstract
ANSYS software was used to analyze the moment-rotation relationship of semi-rigid steel structure joints with bolted connection. A parametric study was conducted to examine the influence of eight key variables—including bolt number, bolt grade, angle steel grade, bolt diameter, angle steel thickness, angle [...] Read more.
ANSYS software was used to analyze the moment-rotation relationship of semi-rigid steel structure joints with bolted connection. A parametric study was conducted to examine the influence of eight key variables—including bolt number, bolt grade, angle steel grade, bolt diameter, angle steel thickness, angle steel width, preload magnitude, and friction coefficient—on the bending behavior of semi-rigid joints with bolted connection. Parametric analysis reveals that the initial rotational stiffness is most significantly influenced by the bolt diameter, the width and thickness of the angle steel, the bolt preload, the coefficient of friction, and the bolt number. The stiffness exhibited an average increase of 50.6% for every 4 mm increment in bolt diameter from 12 mm to 24 mm. Expanding the angle steel width from 50 mm to 75 mm resulted in a substantial 88.5% average increase in stiffness, while a further width increase from 75 mm to 110 mm led to a smaller average increase of 17.4% per 17.5 mm. Similarly, the stiffness rose by an average of 33.8% for every 2 mm increase in the thickness of the angle steel within the 4 mm to 10 mm range. A 25% increase in bolt preload correlated with a modest average stiffness gain of 2.7%. The rate of stiffness improvement diminished with increasing friction coefficient. In contrast, the initial rotational stiffness exhibited a relationship that is approximately linear with respect to the quantity of bolts. Regarding the ultimate bending moment, the key influencing factors were identified as bolt diameter, preload, coefficient of friction, and number of bolts. The ultimate moment demonstrated a non-monotonic relationship with bolt diameter, characterized by an initial increase, followed by a decrease, and then a sharp subsequent rise. Linear enhancements in the ultimate moment were observed with increases in both bolt preload and coefficient of friction. Furthermore, the ultimate bending moment showed a gradual increase with the number of bolts. Based on the results, a bending moment-rotation curve model of joints with bolted connection is established, and the expression of each parameter in the model is calculated. This model can be applied to simulation of the bending performance of semi-rigid joints with bolted connection. Full article
Show Figures

Figure 1

21 pages, 23506 KB  
Article
Experimental and Numerical Analysis of a Bolted Angle Connector Beam-to-Column Joint with a Stiffener
by Zongmin Zhang, Lanhua Chen and Peng Yuan
Buildings 2026, 16(1), 180; https://doi.org/10.3390/buildings16010180 - 31 Dec 2025
Viewed by 824
Abstract
The seismic performance of a proposed bolted angle connector beam-to-column joint with a stiffener (hereinafter referred to as a BACS joint) was investigated utilizing quasi-static tests on six specimens with H-shaped steel members. The failure modes, hysteretic curves, skeleton curves, stiffness degradation, and [...] Read more.
The seismic performance of a proposed bolted angle connector beam-to-column joint with a stiffener (hereinafter referred to as a BACS joint) was investigated utilizing quasi-static tests on six specimens with H-shaped steel members. The failure modes, hysteretic curves, skeleton curves, stiffness degradation, and energy dissipation capacity were analyzed. The test results indicated that the BACS joint exhibited a 28.1% higher moment resistance and a 12.6% greater equivalent viscous damping coefficient compared to a welded connection with the same specifications. Furthermore, when compared to a short-beam spliced connection with comparable steel consumption, the BACS joint demonstrated advantages in both the load-bearing capacity and the energy dissipation. The numerical analysis results based on ABAQUS software demonstrated that increasing the stiffener height could not only enhance the bending capacity and stiffness of the connection, but also promote the relocation of the plastic hinge towards the beam end, thereby improving the failure mode. The increase in the stiffener thickness led to a minor improvement in the bending capacity of the connection, yet the influence of the stiffener thickness on the connection stiffness was limited. Furthermore, the use of steel with a higher strength grade could substantially increase the bending capacity of the BACS joint, while the enhancement in stiffness was relatively modest. Therefore, economic considerations should be integrated into the engineering design process. Full article
(This article belongs to the Section Building Structures)
Show Figures

Figure 1

25 pages, 4115 KB  
Article
Rock Mass Failure Classification Based on FAHP–Entropy Weight TOPSIS Method and Roadway Zoning Repair Design
by Biao Huang, Qinghu Wei, Zhongguang Sun, Kang Guo and Ming Ji
Processes 2025, 13(10), 3154; https://doi.org/10.3390/pr13103154 - 2 Oct 2025
Viewed by 776
Abstract
After the original support system in the auxiliary transportation roadway of the northern wing of the Zhaoxian Mine failed, the extent of damage and deformation varied significantly across different sections of the drift. A single support method could not meet the engineering requirements. [...] Read more.
After the original support system in the auxiliary transportation roadway of the northern wing of the Zhaoxian Mine failed, the extent of damage and deformation varied significantly across different sections of the drift. A single support method could not meet the engineering requirements. Therefore, this paper conducted research on the classification of roadway damage and zoning repair. The overall damage characteristics of the roadway are described by three indicators: roadway deformation, development of rock mass fractures, and water seepage conditions. These are further refined into nine secondary indicators. In summary, a rock mass damage combination weighting evaluation model based on the FAHP–entropy weight TOPSIS method is proposed. According to this model, the degree of damage to the roadway is divided into five grades. After analyzing the damage conditions and support requirements at each grade, corresponding zoning repair plans are formulated by adjusting the parameters of bolts, cables, channel steel beams, and grouting materials. At the same time, the reliability of partition repair is verified using FLAC3D 6.0 numerical simulation software. Field monitoring results demonstrated that this approach not only met the support requirements for the roadway but also improved the utilization rate of support materials. This provides valuable guidance for the design of support systems for roadways with similar heterogeneous damage. Full article
(This article belongs to the Section Process Control, Modeling and Optimization)
Show Figures

Figure 1

27 pages, 7936 KB  
Article
Analytical Method for Tunnel Support Parameter Design Based on Surrounding Rock Failure Mode Identification
by Lantian Wang, Peng He, Zhenghu Ma, Ning Liu, Chuanxin Yang and Yaohui Gao
Geosciences 2025, 15(9), 369; https://doi.org/10.3390/geosciences15090369 - 22 Sep 2025
Cited by 3 | Viewed by 2929
Abstract
Accurately identifying surrounding rock failure modes and designing matching support systems are critical to the safety of deep-earth and underground space engineering. We develop a graded classification scheme based on the rock strength-to-stress ratio and the Stress Reduction Factor (SRF) to quantify failure [...] Read more.
Accurately identifying surrounding rock failure modes and designing matching support systems are critical to the safety of deep-earth and underground space engineering. We develop a graded classification scheme based on the rock strength-to-stress ratio and the Stress Reduction Factor (SRF) to quantify failure types and guide support design. Within the convergence–confinement method (CCM) framework, we establish analytical models for shotcrete, rock bolts, steel arches, and composite support systems, enabling parameterized calculations of stiffness, load-bearing capacity, and equilibrium conditions. We conduct single-factor sensitivity analyses to reveal how the Geological Strength Index (GSI), burial depth (H), and equivalent tunnel radius (R0) govern the evolution of surrounding rock pressure and deformation. We propose targeted reinforcement strategies that address large-deformation and high-stress instabilities in practice by linking observed or predicted failure modes to specific support schemes. A large-deformation case study verifies that the proposed parameterized design method accurately predicts the equilibrium support pressure and radial deformation, and the designed support scheme markedly reduces convergence. Accordingly, this study provides a practical tool for tunnel support parameter design and an analytical platform for safe, reliable, and efficient decision making for initial support. Full article
Show Figures

Figure 1

20 pages, 4662 KB  
Article
Experimental Study on the Shear Performance of Epoxy Resin-Bolted Steel-Cross Laminated Timber (CLT) Connections
by Qing Lyu, Jinxun Ye, Huake Wang, Jiale Xu, Yunfeng Xiao, Bo Fu, Xianlei Li and Zhaoyang Zhang
Buildings 2025, 15(18), 3400; https://doi.org/10.3390/buildings15183400 - 19 Sep 2025
Cited by 1 | Viewed by 1211
Abstract
Steel–timber composite (STC) structures offer a sustainable and low-carbon structural solution. Steel–timber interface behavior is critical for the mechanical performance of STC structures. This paper introduces a novel connection for steel–timber composites (STC) that combines mechanical interlocking with adhesive bonding through an epoxy-bonded [...] Read more.
Steel–timber composite (STC) structures offer a sustainable and low-carbon structural solution. Steel–timber interface behavior is critical for the mechanical performance of STC structures. This paper introduces a novel connection for steel–timber composites (STC) that combines mechanical interlocking with adhesive bonding through an epoxy-bonded bolted design. Epoxy resin is injected into the timber dowel slots, followed by pre-tightening of the bolts, forming a composite dowel system where the ‘bolt–epoxy resin–timber’ components work in synergy. The load–displacement characteristics and failure modes of nine specimen groups were investigated through a series of double-shear push-out tests. The influence of a wide range of connector parameters on the stiffness, shear bearing capacity, and ductility of STC joints was systematically investigated. The parameters included fastener strength grade, thread configuration, diameter, number, and the use of epoxy resin reinforcement. The experimental results demonstrated that high-strength partially threaded bolts were crucial for achieving a synergy of high load-bearing capacity and commendable ductility, while full-threaded bolts exhibited vulnerability to brittle shear failure, a consequence of stress concentration at the root of the threads. Although screw connections provided enhanced initial stiffness through timber anchorage, ordinary bolt connections exhibited superior ultimate load-bearing capacity. In comparison with conventional bolt connections, epoxy resin–bolt connections exhibited enhanced mechanical properties, with an augmentation in ultimate load and initial stiffness of 12% and 11.8%, respectively, without sacrificing ductility. Full article
(This article belongs to the Special Issue Advances and Applications in Timber Structures)
Show Figures

Figure 1

29 pages, 416 KB  
Article
RETRACTED: Seismic Performance of Space-Saving Special-Shaped Concrete-Filled Steel Tube (CFST) Frames with Different Joint Types: Symmetry Effects and Design Implications for Civil Transportation Buildings
by Liying Zhang and Jingfeng Xia
Symmetry 2025, 17(9), 1545; https://doi.org/10.3390/sym17091545 - 15 Sep 2025
Cited by 1 | Viewed by 1373 | Retraction
Abstract
Special-shaped concrete-filled steel tube (CFST) frames can be embedded in partition walls to improve space utilization, but their frame-level seismic behavior across joint types remains under-documented. This study examines six two-story, single-bay frames with cruciform, T-, and L-shaped CFST columns and three joint [...] Read more.
Special-shaped concrete-filled steel tube (CFST) frames can be embedded in partition walls to improve space utilization, but their frame-level seismic behavior across joint types remains under-documented. This study examines six two-story, single-bay frames with cruciform, T-, and L-shaped CFST columns and three joint configurations: external hoops with vertical ribs, fully bolted joints, and fully bolted joints with replaceable flange plates. Low-cycle reversed loading tests were combined with validated ABAQUS and OpenSees models to interpret mechanisms and conduct parametric analyses. All frames exhibited stable spindle-shaped hysteresis with minor pinching; equivalent viscous damping reached 0.13–0.25, ductility coefficients 3.03–3.69, and drift angles 0.088–0.126 rad. Hooped-and-ribbed joints showed the highest capacity and energy dissipation, while replaceable joints localized damage for rapid repair. Parametric results revealed that increasing the steel grade and steel ratio (≈5–20%) improved seismic indices more effectively than raising the concrete strength. Recommended design windows include axial load ratio < 0.4–0.5, slenderness ≤ 30, stiffness ratio ≈ 0.36, and flexural-capacity ratio ≈ 1.0. These findings provide symmetry-based, repair-oriented guidance for transportation buildings requiring rapid post-earthquake recovery. Full article
33 pages, 12112 KB  
Article
Innovative Retrofitting for Disaster Resilience: Optimizing Steel Plate Grade and Scheme in RC Non-Seismic Frames to Prevent Progressive Collapse
by Hussein M. Elsanadedy, Tarek H. Almusallam, Husain Abbas and Yousef A. Al-Salloum
Buildings 2025, 15(18), 3325; https://doi.org/10.3390/buildings15183325 - 14 Sep 2025
Cited by 4 | Viewed by 1031
Abstract
Reinforced concrete (RC) non-seismic frames in Middle Eastern multistory buildings often have beam–column connections with discontinuous bottom reinforcement, heightening the risk of progressive collapse if an outer column fails. This study aimed to reduce the potential for progressive collapse when a column is [...] Read more.
Reinforced concrete (RC) non-seismic frames in Middle Eastern multistory buildings often have beam–column connections with discontinuous bottom reinforcement, heightening the risk of progressive collapse if an outer column fails. This study aimed to reduce the potential for progressive collapse when a column is lost by investigating the use of bolted steel plates to enhance the beam–column joints of such frames. In this regard, high-fidelity finite element (FE) analysis was carried out on ten half-scale, two-span, two-story RC frames to simulate the removal of a center column. The numerical analysis accounted for the nonlinear rate-dependent response of steel and concrete, as well as the bond-slip model at steel bars/concrete interaction. The analysis matrix had three unstrengthened specimens that served as references for comparison, in addition to seven assemblies, which were strengthened using bolted steel plates. In the upgraded assemblies, the studied variables were the grade of steel plate (three grades were examined) and the upgrading scheme (three different schemes were investigated). The performance of the specimens was evaluated by comparing their failure patterns and the characteristics of load versus displacement of the middle column during both flexural and catenary action phases. Based on this comparison, the most efficient strengthening method was suggested. Full article
(This article belongs to the Section Building Structures)
Show Figures

Figure 1

22 pages, 2892 KB  
Article
Investigation of Bolt Grade Influence on the Structural Integrity of L-Type Flange Joints Using Finite Element Analysis
by Muhammad Waleed and Daeyong Lee
J. Mar. Sci. Eng. 2025, 13(7), 1346; https://doi.org/10.3390/jmse13071346 - 15 Jul 2025
Cited by 4 | Viewed by 2460
Abstract
Critical components in support structures for wind turbines, flange joints, are fundamental to ensure the structural integrity of mechanical assemblies under varying operational conditions. This paper investigates the structural performance of L-type flange joints, focusing on the influence of bolt grades and bolt [...] Read more.
Critical components in support structures for wind turbines, flange joints, are fundamental to ensure the structural integrity of mechanical assemblies under varying operational conditions. This paper investigates the structural performance of L-type flange joints, focusing on the influence of bolt grades and bolt pretension through a finite element analysis (FEA) study of its key performance indicators, including stress distribution, deformation, and force–displacement behaviors. This paper studies two high-strength bolt grades, Grade 10.9 and Grade 12.9, and two main steps—first, bolt pretension and, second, external loading (tower shell tensile load)—to investigate the influence on joint reliability and safety margins. The novelty of this study lies in its specific focus on static axial loading conditions, unlike the existing literature that emphasizes fatigue or dynamic loads. Results show that the specimen carrying a higher bolt grade (12.9) has 18% more ultimate load carrying capacity than the specimen with a lower bolt grade (10.9). Increased pretension increases the stability of the joint and reduces the micro-movements between A and B (on model specimen), but could result in material fatigue if over-pretensioned. Comparative analysis of the different bolt grades has provided practical guidance on material selection and bolt pretension in L-type flange joints for wind turbine support structures. The findings of this work offer insights into the proper design of robust flange connections for high-demand applications by highlighting a balance among material properties, bolt pretension, and operational conditions, while also proposing optimized pretension and material recommendations validated against classical analytical models. Full article
(This article belongs to the Section Ocean Engineering)
Show Figures

Figure 1

Back to TopTop