Sign in to use this feature.

Years

Between: -

Subjects

remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline

Journals

Article Types

Countries / Regions

Search Results (22)

Search Parameters:
Keywords = fetal ECG extraction

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
26 pages, 4414 KB  
Article
MCA-FM: Robust Non-Invasive Fetal ECG Extraction via Minimal Channel Attention and Flow Matching
by Qingqing Duan, Xinyu Hu, Yuwei Zhang, Zhijun Xiao and Chengyu Liu
Appl. Sci. 2026, 16(12), 5953; https://doi.org/10.3390/app16125953 - 12 Jun 2026
Viewed by 172
Abstract
Non-invasive fetal electrocardiogram (FECG) extraction from maternal abdominal ECG (AECG) is crucial for prenatal monitoring but remains challenging due to strong interference from maternal ECG (MECG), baseline drift, and noise. We propose an FECG extraction method based on minimal channel attention (MCA) and [...] Read more.
Non-invasive fetal electrocardiogram (FECG) extraction from maternal abdominal ECG (AECG) is crucial for prenatal monitoring but remains challenging due to strong interference from maternal ECG (MECG), baseline drift, and noise. We propose an FECG extraction method based on minimal channel attention (MCA) and flow matching (FM), learning a deterministic mapping from AECG to FECG via a probabilistic path. To balance the preservation of physiological signals and separation of interference, we employ bridge variance scheduling for the diffusion process. Target matching loss is introduced to regress the FECG directly, enhancing training stability and waveform fidelity. For feature selection, a minimal channel attention module with global average pooling and a single linear layer is embedded after feature extraction, capturing cross-channel dependencies with minimal parameters. Enhanced residual connections are incorporated to retain underlying features and optimize gradient flow in deep networks. Experiments on two public datasets (ADDB and BDDB) with a leave-one-out cross-validation strategy show that our method achieves average Pearson correlation coefficients (PCCs) of 0.94 ± 0.050 on ADDB and 0.91 ± 0.122 on BDDB, demonstrating robust performance across diverse real-world recording conditions. The method balances high accuracy with efficient feature extraction, offering a reliable solution for non-invasive fetal heart health monitoring. Full article
(This article belongs to the Special Issue Research and Technology in Electrocardiology)
Show Figures

Figure 1

19 pages, 5215 KB  
Study Protocol
Fetal ECG Signal Extraction from Maternal Abdominal ECG Signals Using Attention R2W-Net
by Lin Chen, Shuicai Wu and Zhuhuang Zhou
Sensors 2025, 25(3), 601; https://doi.org/10.3390/s25030601 - 21 Jan 2025
Cited by 17 | Viewed by 5701
Abstract
Fetal electrocardiogram (FECG) signals directly reflect the electrical activity of the fetal heart, enabling the assessment of fetal cardiac health. To effectively separate and extract FECG signals from maternal abdominal electrocardiogram (ECG) signals, this study proposed a W-shaped parallel network, termed Attention R2W-Net, [...] Read more.
Fetal electrocardiogram (FECG) signals directly reflect the electrical activity of the fetal heart, enabling the assessment of fetal cardiac health. To effectively separate and extract FECG signals from maternal abdominal electrocardiogram (ECG) signals, this study proposed a W-shaped parallel network, termed Attention R2W-Net, which consisted of two Attention R2U-Nets. In the encoder and decoder, recurrent residual modules were used to replace feedforward convolutional layers, significantly enhancing feature representation and improving noise suppression. Additionally, attention gates were used to replace skip connections, enabling precise correction of low-resolution features using deep features and further improving model performance. The decoders at both ends of the network were utilized to reconstruct FECG and MECG signals, respectively. The algorithm was validated using simulated and real datasets, achieving F1 scores of 99.17%, 98.03%, and 97.08% on the ADFECGDB, PCDB, and NIFECGDB datasets, respectively, demonstrating superior performance in both subjective visual effects and objective evaluation metrics. Attention R2W-Net’s ability to extract robustly and accurately FECG signals, even in complex noisy environments, make it a reliable tool for FECG extraction. The proposed method’s efficiency and accuracy highlight its potential for widespread clinical application, contributing to improved early diagnosis of fetal cardiac abnormalities. Full article
(This article belongs to the Section Biomedical Sensors)
Show Figures

Figure 1

14 pages, 3241 KB  
Article
A Non-Invasive Fetal QRS Complex Detection Method Based on a Multi-Feature Fusion Neural Network
by Zhuya Huang, Junsheng Yu, Ying Shan and Xiangqing Wang
Appl. Sci. 2024, 14(19), 8987; https://doi.org/10.3390/app14198987 - 5 Oct 2024
Cited by 7 | Viewed by 2866
Abstract
Fetal heart monitoring, as a crucial part of fetal monitoring, can accurately reflect the fetus’s health status in a timely manner. To address the issues of high computational cost, inability to observe fetal heart morphology, and insufficient accuracy associated with the traditional method [...] Read more.
Fetal heart monitoring, as a crucial part of fetal monitoring, can accurately reflect the fetus’s health status in a timely manner. To address the issues of high computational cost, inability to observe fetal heart morphology, and insufficient accuracy associated with the traditional method of calculating the fetal heart rate using a four-channel maternal electrocardiogram (ECG), a method for extracting fetal QRS complexes from a single-channel non-invasive fetal ECG based on a multi-feature fusion neural network is proposed. Firstly, a signal entropy data quality detection algorithm based on the blind source separation method is designed to select maternal ECG signals that meet the quality requirements from all channel ECG data, followed by data preprocessing operations such as denoising and normalization on the signals. After being segmented by the sliding window method, the maternal ECG signals are calculated as data in four modes: time domain, frequency domain, time–frequency domain, and data eigenvalues. Finally, the deep neural network using three multi-feature fusion strategies—feature-level fusion, decision-level fusion, and model-level fusion—achieves the effect of quickly identifying fetal QRS complexes. Among the proposed networks, the one with the best performance has an accuracy of 95.85% and sensitivity of 97%. Full article
(This article belongs to the Section Biomedical Engineering)
Show Figures

Figure 1

12 pages, 3824 KB  
Article
The Development and Implementation of Innovative Blind Source Separation Techniques for Real-Time Extraction and Analysis of Fetal and Maternal Electrocardiogram Signals
by Mohcin Mekhfioui, Aziz Benahmed, Ahmed Chebak, Rachid Elgouri and Laamari Hlou
Bioengineering 2024, 11(5), 512; https://doi.org/10.3390/bioengineering11050512 - 19 May 2024
Cited by 12 | Viewed by 3480
Abstract
This article presents an innovative approach to analyzing and extracting electrocardiogram (ECG) signals from the abdomen and thorax of pregnant women, with the primary goal of isolating fetal ECG (fECG) and maternal ECG (mECG) signals. To resolve the difficulties related to the low [...] Read more.
This article presents an innovative approach to analyzing and extracting electrocardiogram (ECG) signals from the abdomen and thorax of pregnant women, with the primary goal of isolating fetal ECG (fECG) and maternal ECG (mECG) signals. To resolve the difficulties related to the low amplitude of the fECG, various noise sources during signal acquisition, and the overlapping of R waves, we developed a new method for extracting ECG signals using blind source separation techniques. This method is based on independent component analysis algorithms to detect and accurately extract fECG and mECG signals from abdomen and thorax data. To validate our approach, we carried out experiments using a real and reliable database for the evaluation of fECG extraction algorithms. Moreover, to demonstrate real-time applicability, we implemented our method in an embedded card linked to electronic modules that measure blood oxygen saturation (SpO2) and body temperature, as well as the transmission of data to a web server. This enables us to present all information related to the fetus and its mother in a mobile application to assist doctors in diagnosing the fetus’s condition. Our results demonstrate the effectiveness of our approach in isolating fECG and mECG signals under difficult conditions and also calculating different heart rates (fBPM and mBPM), which offers promising prospects for improving fetal monitoring and maternal healthcare during pregnancy. Full article
(This article belongs to the Section Biosignal Processing)
Show Figures

Figure 1

21 pages, 5800 KB  
Article
Enhancing Fetal Electrocardiogram Signal Extraction Accuracy through a CycleGAN Utilizing Combined CNN–BiLSTM Architecture
by Yuyao Yang, Lin Chen and Shuicai Wu
Sensors 2024, 24(9), 2948; https://doi.org/10.3390/s24092948 - 6 May 2024
Cited by 14 | Viewed by 3674
Abstract
The fetal electrocardiogram (FECG) records changes in the graph of fetal cardiac action potential during conduction, reflecting the developmental status of the fetus in utero and its physiological cardiac activity. Morphological alterations in the FECG can indicate intrauterine hypoxia, fetal distress, and neonatal [...] Read more.
The fetal electrocardiogram (FECG) records changes in the graph of fetal cardiac action potential during conduction, reflecting the developmental status of the fetus in utero and its physiological cardiac activity. Morphological alterations in the FECG can indicate intrauterine hypoxia, fetal distress, and neonatal asphyxia early on, enhancing maternal and fetal safety through prompt clinical intervention, thereby reducing neonatal morbidity and mortality. To reconstruct FECG signals with clear morphological information, this paper proposes a novel deep learning model, CBLS-CycleGAN. The model’s generator combines spatial features extracted by the CNN with temporal features extracted by the BiLSTM network, thus ensuring that the reconstructed signals possess combined features with spatial and temporal dependencies. The model’s discriminator utilizes PatchGAN, employing small segments of the signal as discriminative inputs to concentrate the training process on capturing signal details. Evaluating the model using two real FECG signal databases, namely “Abdominal and Direct Fetal ECG Database” and “Fetal Electrocardiograms, Direct and Abdominal with Reference Heartbeat Annotations”, resulted in a mean MSE and MAE of 0.019 and 0.006, respectively. It detects the FQRS compound wave with a sensitivity, positive predictive value, and F1 of 99.51%, 99.57%, and 99.54%, respectively. This paper’s model effectively preserves the morphological information of FECG signals, capturing not only the FQRS compound wave but also the fetal P-wave, T-wave, P-R interval, and ST segment information, providing clinicians with crucial diagnostic insights and a scientific foundation for developing rational treatment protocols. Full article
(This article belongs to the Section Biomedical Sensors)
Show Figures

Figure 1

31 pages, 12480 KB  
Article
PCA-Based Preprocessing for Clustering-Based Fetal Heart Rate Extraction in Non-Invasive Fetal Electrocardiograms
by Luis Oyarzún, Encarnación Castillo, Luis Parrilla, Uwe Meyer-Baese and Antonio García
Electronics 2024, 13(7), 1264; https://doi.org/10.3390/electronics13071264 - 28 Mar 2024
Cited by 3 | Viewed by 2167
Abstract
Non-invasive fetal electrocardiography (NI-ECG) is based on the acquisition of signals from electrodes on the mother’s abdominal surface. This abdominal ECG (aECG) signal consists of the maternal ECG (mECG) along with the fetal ECG (fECG) and other noises and artifacts. These records allow [...] Read more.
Non-invasive fetal electrocardiography (NI-ECG) is based on the acquisition of signals from electrodes on the mother’s abdominal surface. This abdominal ECG (aECG) signal consists of the maternal ECG (mECG) along with the fetal ECG (fECG) and other noises and artifacts. These records allow the acquisition of valuable and reliable information that helps ensure fetal well-being during pregnancy. This paper proposes a procedure based on principal component analysis (PCA) to obtain a single-channel master abdominal ECG record that can be used as input to fetal heart rate extraction techniques. The new procedure requires three main processing stages: PCA-based analysis for fECG-component extraction, polarity test, and curve fitting. To show the advantages of the proposal, this PCA-based method has been used as the feeding stage to a previously developed clustering-based method for single-channel aECG fetal heart rate monitoring. The results obtained for a set of real abdominal ECG recordings from annotated public aECG databases, the Abdominal and Direct Fetal ECG Database and the Challenge 2013 Training Set A, show improved efficiency in fetal heart rate extraction and illustrate the benefits derived from the use of such a master abdominal ECG channel. This allows us to achieve proper fetal heart rate monitoring without the need for manual inspection and selection of channels to be processed, while also allowing us to analyze records that would have been discarded otherwise. Full article
Show Figures

Figure 1

17 pages, 2610 KB  
Article
Unsupervised Learning-Based Non-Invasive Fetal ECG Muti-Level Signal Quality Assessment
by Xintong Shi, Kohei Yamamoto, Tomoaki Ohtsuki, Yutaka Matsui and Kazunari Owada
Bioengineering 2023, 10(1), 66; https://doi.org/10.3390/bioengineering10010066 - 4 Jan 2023
Cited by 7 | Viewed by 4441
Abstract
Objective: To monitor fetal health and growth, fetal heart rate is a critical indicator. The non-invasive fetal electrocardiogram is a widely employed measurement for fetal heart rate estimation, which is extracted from the electrodes placed on the surface of the maternal abdomen. The [...] Read more.
Objective: To monitor fetal health and growth, fetal heart rate is a critical indicator. The non-invasive fetal electrocardiogram is a widely employed measurement for fetal heart rate estimation, which is extracted from the electrodes placed on the surface of the maternal abdomen. The qualities of the fetal ECG recordings, however, are frequently affected by the noises from various interference sources. In general, the fetal heart rate estimates are unreliable when low-quality fetal ECG signals are used for fetal heart rate estimation, which makes accurate fetal heart rate estimation a challenging task. So, the signal quality assessment for the fetal ECG records is an essential step before fetal heart rate estimation. In other words, some low-quality fetal ECG signal segments are supposed to be detected and removed by utilizing signal quality assessment, so as to improve the accuracy of fetal heart rate estimation. A few supervised learning-based fetal ECG signal quality assessment approaches have been introduced and shown to accurately classify high- and low-quality fetal ECG signal segments, but large fetal ECG datasets with quality annotation are required in these methods. Yet, the labeled fetal ECG datasets are limited. Proposed methods: An unsupervised learning-based multi-level fetal ECG signal quality assessment approach is proposed in this paper for identifying three levels of fetal ECG signal quality. We extracted some features associated with signal quality, including entropy-based features, statistical features, and ECG signal quality indices. Additionally, an autoencoder-based feature is calculated, which is related to the reconstruction error of the spectrograms generated from fetal ECG signal segments. The high-, medium-, and low-quality fetal ECG signal segments are classified by inputting these features into a self-organizing map. Main results: The experimental results showed that our proposal achieved a weighted average F1-score of 90% in three-level fetal ECG signal quality classification. Moreover, with the acceptable removal of detected low-quality signal segments, the errors of fetal heart rate estimation were reduced to a certain extent. Full article
(This article belongs to the Special Issue Monitoring and Analysis of Human Biosignals)
Show Figures

Graphical abstract

15 pages, 3403 KB  
Article
Wearable Fetal ECG Monitoring System from Abdominal Electrocardiography Recording
by Yuwei Zhang, Aihua Gu, Zhijun Xiao, Yantao Xing, Chenxi Yang, Jianqing Li and Chengyu Liu
Biosensors 2022, 12(7), 475; https://doi.org/10.3390/bios12070475 - 30 Jun 2022
Cited by 43 | Viewed by 8399
Abstract
Fetal electrocardiography (ECG) monitoring during pregnancy can provide crucial information for assessing the fetus’s health status and making timely decisions. This paper proposes a portable ECG monitoring system to record the abdominal ECG (AECG) of the pregnant woman, comprising both maternal ECG (MECG) [...] Read more.
Fetal electrocardiography (ECG) monitoring during pregnancy can provide crucial information for assessing the fetus’s health status and making timely decisions. This paper proposes a portable ECG monitoring system to record the abdominal ECG (AECG) of the pregnant woman, comprising both maternal ECG (MECG) and fetal ECG (FECG), which could be applied to fetal heart rate (FHR) monitoring at the home setting. The ECG monitoring system is based on data acquisition circuits, data transmission module, and signal analysis platform, which consists of low input-referred noise, high input impedance, and high resolution. The combination of the adaptive dual threshold (ADT) and the independent component analysis (ICA) algorithm is employed to extract the FECG from the AECG signals. To validate the performance of the proposed system, AECG is recorded and analyzed of pregnant women in three different postures (supine, seated, and standing). The result shows that the proposed system can record the AECG in different postures with good signal quality and high accuracy in fetal ECG and heart rate information. Sensitivity (Se), positive predictive accuracy (PPV), accuracy (ACC), and their harmonic mean (F1) are utilized as the metrics to evaluate the performance of the fetal QRS (fQRS) complexes extraction. The average Se, PPV, ACC, and F1 score are 99.62%, 97.90%, 97.40%, and 98.66% for the fQRS complexes extraction,, respectively. This paper shows the proposed system has a promising application in fetal health monitoring. Full article
(This article belongs to the Special Issue Biomedical Signal Processing in Healthcare and Disease Diagnosis)
Show Figures

Figure 1

17 pages, 4865 KB  
Article
Fetal Electrocardiogram Signal Extraction Based on Fast Independent Component Analysis and Singular Value Decomposition
by Jingyu Hao, Yuyao Yang, Zhuhuang Zhou and Shuicai Wu
Sensors 2022, 22(10), 3705; https://doi.org/10.3390/s22103705 - 12 May 2022
Cited by 26 | Viewed by 4737
Abstract
Fetal electrocardiograms (FECGs) provide important clinical information for early diagnosis and intervention. However, FECG signals are extremely weak and are greatly influenced by noises. FECG signal extraction and detection are still challenging. In this work, we combined the fast independent component analysis (FastICA) [...] Read more.
Fetal electrocardiograms (FECGs) provide important clinical information for early diagnosis and intervention. However, FECG signals are extremely weak and are greatly influenced by noises. FECG signal extraction and detection are still challenging. In this work, we combined the fast independent component analysis (FastICA) algorithm with singular value decomposition (SVD) to extract FECG signals. The improved wavelet mode maximum method was applied to detect QRS waves and ST segments of FECG signals. We used the abdominal and direct fetal ECG database (ADFECGDB) and the Cardiology Challenge Database (PhysioNet2013) to verify the proposed algorithm. The signal-to-noise ratio of the best channel signal reached 45.028 dB and the issue of missing waveforms was addressed. The sensitivity, positive predictive value and F1 score of fetal QRS wave detection were 96.90%, 98.23%, and 95.24%, respectively. The proposed algorithm may be used as a new method for FECG signal extraction and detection. Full article
(This article belongs to the Section Biomedical Sensors)
Show Figures

Figure 1

14 pages, 1796 KB  
Article
Fetal Electrocardiogram Extraction from the Mother’s Abdominal Signal Using the Ensemble Kalman Filter
by Sadaf Sarafan, Tai Le, Michael P. H. Lau, Afshan Hameed, Tadesse Ghirmai and Hung Cao
Sensors 2022, 22(7), 2788; https://doi.org/10.3390/s22072788 - 5 Apr 2022
Cited by 25 | Viewed by 3927
Abstract
Fetal electrocardiogram (fECG) assessment is essential throughout pregnancy to monitor the wellbeing and development of the fetus, and to possibly diagnose potential congenital heart defects. Due to the high noise incorporated in the abdominal ECG (aECG) signals, the extraction of fECG has been [...] Read more.
Fetal electrocardiogram (fECG) assessment is essential throughout pregnancy to monitor the wellbeing and development of the fetus, and to possibly diagnose potential congenital heart defects. Due to the high noise incorporated in the abdominal ECG (aECG) signals, the extraction of fECG has been challenging. And it is even a lot more difficult for fECG extraction if only one channel of aECG is provided, i.e., in a compact patch device. In this paper, we propose a novel algorithm based on the Ensemble Kalman filter (EnKF) for non-invasive fECG extraction from a single-channel aECG signal. To assess the performance of the proposed algorithm, we used our own clinical data, obtained from a pilot study with 10 subjects each of 20 min recording, and data from the PhysioNet 2013 Challenge bank with labeled QRS complex annotations. The proposed methodology shows the average positive predictive value (PPV) of 97.59%, sensitivity (SE) of 96.91%, and F1-score of 97.25% from the PhysioNet 2013 Challenge bank. Our results also indicate that the proposed algorithm is reliable and effective, and it outperforms the recently proposed extended Kalman filter (EKF) based algorithm. Full article
(This article belongs to the Collection Wearable and Unobtrusive Biomedical Monitoring)
Show Figures

Figure 1

29 pages, 1014 KB  
Article
Clifford Wavelet Entropy for Fetal ECG Extraction
by Malika Jallouli, Sabrine Arfaoui, Anouar Ben Mabrouk and Carlo Cattani
Entropy 2021, 23(7), 844; https://doi.org/10.3390/e23070844 - 30 Jun 2021
Cited by 20 | Viewed by 4083
Abstract
Analysis of the fetal heart rate during pregnancy is essential for monitoring the proper development of the fetus. Current fetal heart monitoring techniques lack the accuracy in fetal heart rate monitoring and features acquisition, resulting in diagnostic medical issues. The challenge lies in [...] Read more.
Analysis of the fetal heart rate during pregnancy is essential for monitoring the proper development of the fetus. Current fetal heart monitoring techniques lack the accuracy in fetal heart rate monitoring and features acquisition, resulting in diagnostic medical issues. The challenge lies in the extraction of the fetal ECG from the mother ECG during pregnancy. This approach has the advantage of being a reliable and non-invasive technique. In the present paper, a wavelet/multiwavelet method is proposed to perfectly extract the fetal ECG parameters from the abdominal mother ECG. In a first step, due to the wavelet/mutiwavelet processing, a denoising procedure is applied to separate the noised parts from the denoised ones. The denoised signal is assumed to be a mixture of both the MECG and the FECG. One of the well-known measures of accuracy in information processing is the concept of entropy. In the present work, a wavelet/multiwavelet Shannon-type entropy is constructed and applied to evaluate the order/disorder of the extracted FECG signal. The experimental results apply to a recent class of Clifford wavelets constructed in Arfaoui, et al. J. Math. Imaging Vis. 2020, 62, 73–97, and Arfaoui, et al. Acta Appl. Math. 2020, 170, 1–35. Additionally, classical Haar–Faber–Schauder wavelets are applied for the purpose of comparison. Two main well-known databases have been applied, the DAISY database and the CinC Challenge 2013 database. The achieved accuracy over the test databases resulted in Se = 100%, PPV = 100% for FECG extraction and peak detection. Full article
(This article belongs to the Special Issue Wavelets, Fractals and Information Theory IV)
Show Figures

Figure 1

13 pages, 2274 KB  
Article
An Efficient and Robust Deep Learning Method with 1-D Octave Convolution to Extract Fetal Electrocardiogram
by Khuong Vo, Tai Le, Amir M. Rahmani, Nikil Dutt and Hung Cao
Sensors 2020, 20(13), 3757; https://doi.org/10.3390/s20133757 - 4 Jul 2020
Cited by 41 | Viewed by 5212
Abstract
The invasive method of fetal electrocardiogram (fECG) monitoring is widely used with electrodes directly attached to the fetal scalp. There are potential risks such as infection and, thus, it is usually carried out during labor in rare cases. Recent advances in electronics and [...] Read more.
The invasive method of fetal electrocardiogram (fECG) monitoring is widely used with electrodes directly attached to the fetal scalp. There are potential risks such as infection and, thus, it is usually carried out during labor in rare cases. Recent advances in electronics and technologies have enabled fECG monitoring from the early stages of pregnancy through fECG extraction from the combined fetal/maternal ECG (f/mECG) signal recorded non-invasively in the abdominal area of the mother. However, cumbersome algorithms that require the reference maternal ECG as well as heavy feature crafting makes out-of-clinics fECG monitoring in daily life not yet feasible. To address these challenges, we proposed a pure end-to-end deep learning model to detect fetal QRS complexes (i.e., the main spikes observed on a fetal ECG waveform). Additionally, the model has the residual network (ResNet) architecture that adopts the novel 1-D octave convolution (OctConv) for learning multiple temporal frequency features, which in turn reduce memory and computational cost. Importantly, the model is capable of highlighting the contribution of regions that are more prominent for the detection. To evaluate our approach, data from the PhysioNet 2013 Challenge with labeled QRS complex annotations were used in the original form, and the data were then modified with Gaussian and motion noise, mimicking real-world scenarios. The model can achieve a F1 score of 91.1% while being able to save more than 50% computing cost with less than 2% performance degradation, demonstrating the effectiveness of our method. Full article
Show Figures

Figure 1

28 pages, 1577 KB  
Article
A Null Space-Based Blind Source Separation for Fetal Electrocardiogram Signals
by Luay Taha and Esam Abdel-Raheem
Sensors 2020, 20(12), 3536; https://doi.org/10.3390/s20123536 - 22 Jun 2020
Cited by 19 | Viewed by 3551
Abstract
This paper presents a new non-invasive deterministic algorithm of extracting the fetal Electrocardiogram (FECG) signal based on a new null space idempotent transformation matrix (NSITM). The mixture matrix is used to compute the ITM. Then, the fetal ECG (FECG) and maternal ECG (MECG) [...] Read more.
This paper presents a new non-invasive deterministic algorithm of extracting the fetal Electrocardiogram (FECG) signal based on a new null space idempotent transformation matrix (NSITM). The mixture matrix is used to compute the ITM. Then, the fetal ECG (FECG) and maternal ECG (MECG) signals are extracted from the null space of the ITM. Next, MECG and FECG peaks detection, control logic, and adaptive comb filter are used to remove the unwanted MECG component from the raw FECG signal, thus extracting a clean FECG signal. The visual results from Daisy and Physionet real databases indicate that the proposed algorithm is effective in extracting the FECG signal, which can be compared with principal component analysis (PCA), fast independent component analysis (FastICA), and parallel linear predictor (PLP) filter algorithms. Results from Physionet synthesized ECG data show considerable improvement in extraction performances over other algorithms used in this work, considering different additive signal-to-noise ratio (SNR) increasing from 0 dB to 12 dB, and considering different fetal-to-maternal SNR increasing from −30 dB to 0 dB. The FECG detection of the NSITM is evaluated using statistical measures and results show considerable improvement in the sensitivity (SE), the accuracy (ACC), and the positive predictive value (PPV), as compared with other algorithms. The study demonstrated that the NSITM is a feasible algorithm for FECG extraction. Full article
(This article belongs to the Section Biosensors)
Show Figures

Figure 1

15 pages, 4125 KB  
Article
Investigation of Methods to Extract Fetal Electrocardiogram from the Mother’s Abdominal Signal in Practical Scenarios
by Sadaf Sarafan, Tai Le, Amir Mohammad Naderi, Quoc-Dinh Nguyen, Brandon Tiang-Yu Kuo, Tadesse Ghirmai, Huy-Dung Han, Michael P. H. Lau and Hung Cao
Technologies 2020, 8(2), 33; https://doi.org/10.3390/technologies8020033 - 5 Jun 2020
Cited by 31 | Viewed by 7737
Abstract
Monitoring of fetal electrocardiogram (fECG) would provide useful information about fetal wellbeing as well as any abnormal development during pregnancy. Recent advances in flexible electronics and wearable technologies have enabled compact devices to acquire personal physiological signals in the home setting, including those [...] Read more.
Monitoring of fetal electrocardiogram (fECG) would provide useful information about fetal wellbeing as well as any abnormal development during pregnancy. Recent advances in flexible electronics and wearable technologies have enabled compact devices to acquire personal physiological signals in the home setting, including those of expectant mothers. However, the high noise level in the daily life renders long-entrenched challenges to extract fECG from the combined fetal/maternal ECG signal recorded in the abdominal area of the mother. Thus, an efficient fECG extraction scheme is a dire need. In this work, we intensively explored various extraction algorithms, including template subtraction (TS), independent component analysis (ICA), and extended Kalman filter (EKF) using the data from the PhysioNet 2013 Challenge. Furthermore, the modified data with Gaussian and motion noise added, mimicking a practical scenario, were utilized to examine the performance of algorithms. Finally, we combined different algorithms together, yielding promising results, with the best performance in the F1 score of 92.61% achieved by an algorithm combining ICA and TS. With the data modified by adding different types of noise, the combination of ICA–TS–ICA showed the highest F1 score of 85.4%. It should be noted that these combined approaches required higher computational complexity, including execution time and allocated memory compared with other methods. Owing to comprehensive examination through various evaluation metrics in different extraction algorithms, this study provides insights into the implementation and operation of state-of-the-art fetal and maternal monitoring systems in the era of mobile health. Full article
Show Figures

Figure 1

14 pages, 3669 KB  
Article
A Fetal ECG Monitoring System Based on the Android Smartphone
by Li Yuan, Yanchao Yuan, Zhuhuang Zhou, Yanping Bai and Shuicai Wu
Sensors 2019, 19(3), 446; https://doi.org/10.3390/s19030446 - 22 Jan 2019
Cited by 45 | Viewed by 14289
Abstract
In this paper, a fetal electrocardiogram (ECG) monitoring system based on the Android smartphone was proposed. We designed a portable low-power fetal ECG collector, which collected maternal abdominal ECG signals in real time. The ECG data were sent to a smartphone client via [...] Read more.
In this paper, a fetal electrocardiogram (ECG) monitoring system based on the Android smartphone was proposed. We designed a portable low-power fetal ECG collector, which collected maternal abdominal ECG signals in real time. The ECG data were sent to a smartphone client via Bluetooth. Smartphone app software was developed based on the Android system. The app integrated the fast fixed-point algorithm for independent component analysis (FastICA) and the sample entropy algorithm, for the sake of real-time extraction of fetal ECG signals from the maternal abdominal ECG signals. The fetal heart rate was computed using the extracted fetal ECG signals. Experimental results showed that the FastICA algorithm can extract a clear fetal ECG, and the sample entropy can correctly determine the channel where the fetal ECG is located. The proposed fetal ECG monitoring system may be feasible for non-invasive, real-time monitoring of fetal ECGs. Full article
(This article belongs to the Special Issue Wearable and Implantable Sensors and Electronics Circuits)
Show Figures

Figure 1

Back to TopTop