Sign in to use this feature.

Years

Between: -

Subjects

remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline

Journals

Article Types

Countries / Regions

Search Results (31)

Search Parameters:
Keywords = endo-crown restoration

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
11 pages, 209 KiB  
Article
Knowledge and Awareness of Dental Students and Practitioners About the Utilization of Endocrown
by Raneem Alfahad, Maryam Quritum, Lamia Hakami, Maha Aldandan, Osama Alharbi, Omar Almasoud, Abdullah Alasafirah and Passent Ellakany
Dent. J. 2025, 13(8), 348; https://doi.org/10.3390/dj13080348 - 29 Jul 2025
Viewed by 236
Abstract
Background/Objectives: The aim of this study was to evaluate the level of awareness among dental students and practitioners regarding the utilization of endocrowns in clinical settings, along with any differences in knowledge based on gender, educational level, and workplace. Methods: A [...] Read more.
Background/Objectives: The aim of this study was to evaluate the level of awareness among dental students and practitioners regarding the utilization of endocrowns in clinical settings, along with any differences in knowledge based on gender, educational level, and workplace. Methods: A cross-sectional online survey-based study was conducted, including 1154 participants from various dental institutions across Saudi Arabia. The questionnaire included demographic data and closed-ended questions focused on knowledge and awareness of endocrowns. Data was analyzed using statistical tests, including chi-square, to see any significant differences. Results: Most participants (81%) had knowledge about endocrowns, mainly from their colleagues. Knowledge levels and preferences (like the use of lithium disilicate and adhesive resin cement) differed based on gender, educational level, and workplace. Male participants and undergraduates showed better awareness in some areas. Faculty members mostly depend on college training, while private practitioners obtain most of their information from workshops. Conclusions: Males showed significant superiority in knowledge about endocrown usage. Colleges were the most prevalent source of information regarding endocrown restorations. Significant molar tooth loss and restricted inter-arch space were the most common reasons for utilizing endocrowns. Moreover, endocrowns were considered a viable alternative to traditional post and core. Full article
(This article belongs to the Special Issue Dental Education: Innovation and Challenge)
17 pages, 3792 KiB  
Article
Influence of Cement Thickness, Dentine Thickness, and Intracoronal Depth on the Fracture Resistance of 3D-Printed Endocrowns: A Pilot In Vitro Study
by Osama Abuabboud, Adrian-George Marinescu, Mihai Paven, Izabella-Maria Kovacs, Luminita Maria Nica, Andrei-Bogdan Faur, Dan Ioan Stoia and Anca Jivănescu
Dent. J. 2025, 13(6), 263; https://doi.org/10.3390/dj13060263 - 12 Jun 2025
Viewed by 976
Abstract
Background/Objectives: Endodontically treated molars are structurally weakened due to internal tissue loss, increasing their risk of fracture. Endocrowns, developed as a conservative alternative to post–core systems, have gained popularity with the rise of digital dentistry, CAD/CAM workflows, and 3D-printed restorations. In this context, [...] Read more.
Background/Objectives: Endodontically treated molars are structurally weakened due to internal tissue loss, increasing their risk of fracture. Endocrowns, developed as a conservative alternative to post–core systems, have gained popularity with the rise of digital dentistry, CAD/CAM workflows, and 3D-printed restorations. In this context, the aim of the present pilot study was to investigate the influence of cement layer thickness, intracoronal depth, and dentine wall thickness on the fracture resistance of molars restored with 3D-printed endocrowns. Methods: Twelve extracted human molars were endodontically treated and restored with endocrowns fabricated from a 3D-printed resin material, SprintRay CrownTM (SprintRay Inc. Los Angeles, CA, USA), via masked stereolithography (MSLA) on a Prusa SL1 printer. Cementation was performed using RelyX Universal Resin Cement (3M, Maplewood, MN USA). Cone beam computed tomography (CBCT) was used to measure the dentine thickness and intracoronal depth before cementation and cement thickness after cementation. The fracture resistance was evaluated using a universal testing machine. For each variable (Td, Dp, Tc), the 12 specimens were divided into two groups (n = 6). Statistical analysis included Pearson correlation, a one-way ANOVA, and the non-parametric Mann–Whitney U test. Results: Within the limitations of this pilot in vitro study, cement thickness demonstrated a strong positive correlation with fracture resistance (r = 0.577) and was the only variable showing statistical significance in the ANOVA (F = 7.847, p = 0.019). In contrast, intracoronal depth and dentine wall thickness exhibited weaker and nonsignificant correlations. No significant mechanical advantage was observed from increasing the pulp chamber depth or peripheral dentine wall thickness. This result was further supported by nonparametric Mann–Whitney U testing (p = 0.015). Conclusions: Cement layer thickness is a key biomechanical factor influencing the fracture resistance of endocrown restorations. Preparation depth and dentine wall geometry appear to have a less direct impact. Full article
(This article belongs to the Special Issue Innovative Materials in Dental Prosthetics)
Show Figures

Graphical abstract

17 pages, 3627 KiB  
Article
Stress Distribution on Endodontically Treated Anterior Teeth Restored via Different Ceramic Materials with Varying Post Lengths Versus Endocrown—A 3D Finite Element Analysis
by Mai Soliman, Nawaf Almutairi, Ali Alenezi, Raya Alenezi, Amal Abdallah A. Abo-Elmagd and Manal M. Abdelhafeez
J. Funct. Biomater. 2025, 16(6), 221; https://doi.org/10.3390/jfb16060221 - 12 Jun 2025
Viewed by 1006
Abstract
Objective: This study aims to evaluate the stress distribution on endodontically treated anterior teeth restored using different restorative materials and different post lengths versus endocrowns employing finite element analysis (FEA). Methods: An extracted human central incisor tooth with a fully formed apex was [...] Read more.
Objective: This study aims to evaluate the stress distribution on endodontically treated anterior teeth restored using different restorative materials and different post lengths versus endocrowns employing finite element analysis (FEA). Methods: An extracted human central incisor tooth with a fully formed apex was scanned using high-resolution cone beam computed tomography (CBCT) to generate 3D finite element models. Six models of restorations of badly destructed central incisor were grouped according to the type of ceramic material and post length versus endocrown restorations. Group V-L: Vita Enamic, long post (10 mm intra-radicular), Group C-L: Celtra Duo, long post (10 mm intra-radicular), Group V-Sh: Vita Enamic, short post (3 mm intra-radicular), Group C-Sh: Celtra Duo, short post (3 mm intra-radicular), Group V-E: Vita Enamic endocrown (3 mm intra-radicular), and Group C-E: Celtra Duo endocrown (3 mm intra-radicular). A static load of 200 N was applied to the palatal surface at a 45 degree angle to the tooth’s long axis. The maximum equivalent von Mises stress and maximum principal stress were analyzed at four locations: the finish line, coronal third of the root (12 mm from the apex), middle third of the root (8 mm from the apex), and apical third of the root (4 mm from the apex). Results: Group C-L exhibited the highest maximum VM stress and PS at the finish line, in addition to the highest maximum VM stress and PS at the root apical third, while group C-Sh reported the least maximum VM stress at the root apical third among the groups. All Celtra Duo groups reported higher maximum VM stress than the corresponding groups of Vita Enamic at the finish line and root coronal thirds. However, at the root middle and apical thirds, both materials recorded similar stresses. Conclusions: Short posts and Vita Enamic endocrowns showed minimal stress, especially at the finish line, while long posts increased stress and fracture risk. The findings support conservative restorations without posts, although clinical validation is needed to confirm their long-term effectiveness and safety. Full article
(This article belongs to the Special Issue Advances in Restorative Dentistry Materials)
Show Figures

Figure 1

20 pages, 3719 KiB  
Article
Effect of Pulpal Base, Restorative Material, and Preparation Type on Marginal and Internal Fit and Fracture Strength of Endocrowns
by Kerem Yılmaz, Hakan Aydın, Fehmi Gönüldaş, Sukan Kara, Özge Çiloğlu, Erdem Özdemir and Zeynep Bilen
Materials 2025, 18(9), 2137; https://doi.org/10.3390/ma18092137 - 6 May 2025
Cited by 1 | Viewed by 2311
Abstract
The aim of this innovative study was to investigate the feasibility of a modified butt joint preparation with two grooves instead of a ferrule when root dentin tissue is limited in mandibular molars. It was also investigated to what extent the effect of [...] Read more.
The aim of this innovative study was to investigate the feasibility of a modified butt joint preparation with two grooves instead of a ferrule when root dentin tissue is limited in mandibular molars. It was also investigated to what extent the effect of these treatment options on marginal and internal fit and fracture strength (FS) varied according to the type of material and whether or not a fiber ribbon was used at the base. Marginal and internal fit were evaluated using the triple-scan protocol. Statistical analysis was conducted via a three-way analysis of variance (ANOVA). The absolute marginal discrepancy (AMD), marginal discrepancy, and overall fit values for the ceramic group were 127 μm, 108 μm, and 120 μm, respectively, while corresponding values for the hybrid ceramic group were 139 μm, 116 μm, and 130 μm (p < 0.05). The mean FS recorded for ceramic restorations was 662 N, whereas hybrid ceramic restorations demonstrated a significantly higher FS of 903 N (p < 0.001). When material type was assessed independently of preparation design and base configuration, both ceramic and hybrid ceramic exceeded the predefined clinical acceptability threshold for AMD; however, they remained within acceptable limits for the remaining parameters. Among the evaluated configurations, hybrid ceramic restorations incorporating ferrules and fiber-reinforced bases exhibited the highest FS values, whereas ceramic restorations with modified biological widths and lacking fiber reinforcement yielded the lowest FS values. Full article
(This article belongs to the Section Biomaterials)
Show Figures

Figure 1

15 pages, 8254 KiB  
Article
Evaluation of Internal Adaptation of Different CAD/CAM Endocrown Materials: A Comparative Microcomputed Tomography Study
by Wala Saad, Abdul Rahman Saleh and Manal Almaslamani
Ceramics 2025, 8(2), 33; https://doi.org/10.3390/ceramics8020033 - 31 Mar 2025
Viewed by 737
Abstract
Objective: The purpose of this investigation was to assess and compare the internal adaptation of different distinct CAD (Computer-aided design)/CAM (Computer-aided manufacturing) endocrown materials: feldspathic porcelain, indirect composite, hybrid ceramic, reinforced lithium disilicate, and lithium disilicate, utilizing microcomputed tomography. Methods: Standardized endocrown restorations [...] Read more.
Objective: The purpose of this investigation was to assess and compare the internal adaptation of different distinct CAD (Computer-aided design)/CAM (Computer-aided manufacturing) endocrown materials: feldspathic porcelain, indirect composite, hybrid ceramic, reinforced lithium disilicate, and lithium disilicate, utilizing microcomputed tomography. Methods: Standardized endocrown restorations were fabricated for mandibular first molar models. A total of seventy-five restorations were evenly allocated into five groups (n = 15 each): Group I (Cerec Blocks), Group II (Lava Ultimate), Group III (PICN Vita Enamic), Group IV (Celtra Duo), and Group V (Cerec Tessera). The restorations were bonded using PANAVIA V5 adhesive resin cement. To evaluate internal adaptations within the restorations, three distinct locations were selected for the acquisition of high-resolution micro-CT scans: the margin, the axial wall, and the pulpal floor. Data were analyzed using SPSS. To identify statistically significant differences among groups, a two-way ANOVA was conducted, followed by post hoc Tukey tests. Results: The statistical analysis did not reveal significant differences in internal gap measurements across the various material groups (p = 0.055). However, significant variations were observed within individual material groups (p < 0.001) at distinct locations, with the most pronounced discrepancies in thickness evident at the pulpal floor. Conclusion: While no significant differences were observed in internal adaptations among the various endocrown materials, substantial intra-group variability, particularly in terms of pulpal floor thickness, was evident. Since the study maintained a consistent preparation design across all groups, the observed variations in internal adaptation are likely attributed to differences in material behavior rather than changes in preparation geometry. Full article
Show Figures

Figure 1

10 pages, 4205 KiB  
Case Report
Endocrown Restoration for an Endodontically Treated Molar: A Step-by-Step Clinical Guide with a 5-Year Follow-Up
by Dimokritos Papalexopoulos, Ashot Torchyan, Eleftheria Pani and Theodora-Kalliopi Samartzi
Adhesives 2025, 1(2), 6; https://doi.org/10.3390/adhesives1020006 - 31 Mar 2025
Viewed by 1757
Abstract
The classical approach for the preparation of an endodontically treated molar with a post and core involves widening the anatomically complex system of canals, which may be narrow or curved with variable angulation. The aforementioned along with the fact that restorative dentistry stands [...] Read more.
The classical approach for the preparation of an endodontically treated molar with a post and core involves widening the anatomically complex system of canals, which may be narrow or curved with variable angulation. The aforementioned along with the fact that restorative dentistry stands against the wastage of tooth tissue make endocrowns an appealing alternative. Bindl and Mörmann first described an all-ceramic crown anchored to the internal portion of the pulp chamber and on the cavity margins, thus obtaining macromechanical retention provided by the axial opposing pulpal walls and microretention attained with the use of adhesive cementation. The purpose of this report is to describe the protocol for the treatment plan selection, preparation, impression, and adhesive cementation of an endocrown with a follow-up of 5 years. A 56-year-old male patient presented to the Postgraduate Clinic of Prosthodontics seeking rehabilitation for tooth No. #36. A clinical examination revealed multiple immediate composite resin restorations with unacceptable morphology and adaptation to the remaining tooth as well as a lack of a contact point but, rather, a large, concave contact area facilitating food entrapment. Since the tooth was endodontically treated, the proposed treatment plan included the fabrication of an all-ceramic endocrown. The steps of preparation, attribution of the correct shape, impression, and adhesive luting under rubber dam isolation are thoroughly described. The final functional and aesthetic result, patient’s satisfaction, and the 5-year follow-up render restorations such as endocrowns, which draw their retention from adhesive luting, a viable alternative to conventional approaches. Full article
Show Figures

Figure 1

12 pages, 3285 KiB  
Article
Biomechanical Behaviors of Molars Restored with Endocrowns Composed of Different Materials
by Zhi Li, Junxin Zhu, Yongxiang Xu, Xudong Bao and Xiaoyan Wang
Materials 2025, 18(2), 250; https://doi.org/10.3390/ma18020250 - 8 Jan 2025
Viewed by 827
Abstract
To assess the biomechanical behaviors of endodontically treated molars (ETMs) restored with endocrowns composed of different materials, forty mandibular molars were assigned to five groups (n = 8 each). Untreated molars constituted the control group (group C); the rest of the teeth that [...] Read more.
To assess the biomechanical behaviors of endodontically treated molars (ETMs) restored with endocrowns composed of different materials, forty mandibular molars were assigned to five groups (n = 8 each). Untreated molars constituted the control group (group C); the rest of the teeth that underwent root canal therapy were restored with endocrowns composed of polycrystalline ceramics (ST zirconia®, UPCERA) in group ZR, lithium disilicate glass ceramics (UP.CAD®, UPCERA) in group LD, resin-based nanoceramics (Hyramic®, UPCERA) in group NC, and feldspathic ceramics (CEREC Blocs®, Sirona) in group FC. All teeth were axially loaded until fracture. The process was recorded using a high-speed camera system, and fractographic analysis was conducted. The results showed that fracture loads did not significantly differ among groups C, LD, and NC; the loads were significantly lower than the load in group ZR but higher than the load in group FC. The mean time from the initial crack to complete tooth fracture varied. Group C had the longest time, followed by group NC; groups ZR, LD, and FC had the shortest time. Similar failure patterns were observed in groups ZR and LD, which were more regular than the pattern in group NC; group FC exhibited the roughest fracture surfaces. Fracture resistance testing combined with a high-speed camera system and fractographic analysis provides a promising modality for studying the biomechanical behaviors of restored teeth. Endocrowns composed of lithium disilicate glass ceramics or resin-based nanoceramics offer alternative restorations for ETMs with extensive coronal loss. Full article
Show Figures

Figure 1

12 pages, 3346 KiB  
Article
Cervical Margin Relocation: Effect of Crown, Endocrown and Onlay Margin Location and Material Type on the Fracture Resistance of Endodontically Treated Molars
by Mohamed Diaa, Walid Al-Zordk, Mutlu Ozcan and Amal Sakrana
Prosthesis 2024, 6(5), 1106-1117; https://doi.org/10.3390/prosthesis6050080 - 6 Sep 2024
Viewed by 2127
Abstract
This study aimed to evaluate the fracture resistance of endodontically treated molars restored with ceramic indirect restorations with and without cervical margin relocation. A total of 120 extracted human maxillary molars were used after MOD cavities preparations with the mesial boxes located 2 [...] Read more.
This study aimed to evaluate the fracture resistance of endodontically treated molars restored with ceramic indirect restorations with and without cervical margin relocation. A total of 120 extracted human maxillary molars were used after MOD cavities preparations with the mesial boxes located 2 mm below CEJ. Specimens were randomly assigned to six groups according to the margin location of each indirect restoration type (n = 20); crown without CMR, crown with CMR, endocrown without CMR, endocrown with CMR, onlay without CMR, and onlay with CMR. Mesial proximal boxes of the MOD cavities were elevated with composite resin in cervical margin relocation groups. Each group was further divided according to indirect restoration material (n = 10); CEREC Tessera and Celtra Press. The specimens were subjected to fracture resistance testing in a universal testing machine. Fracture analysis was performed using stereo and scanning electron microscopes. Data were analyzed by using 3-way ANOVA, 1-way ANOVA and the Tukey HSD tests (α = 0.05). The mean fracture resistance values ranged between 2136.57 and 950.47 N. Significantly higher values were detected among Celtra Press than Cerec Tessera in crown restorations. Unrestorable fracture patterns were seen through all study groups. Crown restorations represented the best restorative option in terms of fracture resistance. Cervical margin relocation adversely affected fracture resistance. However, the material of the indirect restorations had no significant impact on fracture resistance. Full article
(This article belongs to the Special Issue Modern Management of Endodontically Treated Teeth)
Show Figures

Figure 1

14 pages, 1803 KiB  
Article
The Influence of Ferrule Design and Pulpal Extensions on the Accuracy of Fit and the Fracture Resistance of Zirconia-Reinforced Lithium Silicate Endocrowns
by Samah Saker, Ahmed Yaseen Alqutaibi, Mohammed Ahmed Alghauli, Danya Hashem, Sary Borzangy, Ahmed E. Farghal, Ahmad A. Alnazzawi, Sultan Ainoosah and Mohammed H. AbdElaziz
Materials 2024, 17(6), 1411; https://doi.org/10.3390/ma17061411 - 20 Mar 2024
Cited by 8 | Viewed by 2297
Abstract
The study aimed to assess the marginal, axial, and internal adaptation, as well as the fracture resistance of zirconia-reinforced lithium silicate (ZLS) endocrowns with varying pulpal inlay extensions and marginal geometry. Sixty extracted maxillary first molar teeth were divided into six groups (n [...] Read more.
The study aimed to assess the marginal, axial, and internal adaptation, as well as the fracture resistance of zirconia-reinforced lithium silicate (ZLS) endocrowns with varying pulpal inlay extensions and marginal geometry. Sixty extracted maxillary first molar teeth were divided into six groups (n = 10) according to pulpal inlay extension and marginal configuration. The first three groups (J2, J3, and J4) utilized prepared teeth for endocrowns without ferrule design and 2 mm, 3 mm, and 4 mm pulpal extensions, respectively. The second three groups (F2, F3, and F4) utilized prepared teeth with 1 mm shoulder margins and 2 mm, 3 mm, and 4 mm pulpal extensions. The endocrowns were fabricated from ZLS blocks using CAD/CAM milling technology. After cementation, the specimens underwent thermal aging for 5000 cycles and were evaluated for marginal adaptation. Using a universal testing machine, the fracture resistance was tested under quasistatic loading (1 mm/min). Two-way ANOVA and the Tukey’s post hoc test were employed for data analysis (p ≤ 0.05). The results of this study revealed that endocrowns without ferrule exhibited superior fracture strength than a 1 mm ferrule design p < 0.05, irrespective of the inlay depth. All designs with and without ferrule and all inlay depths showed clinically acceptable marginal and internal fit. The conventional endocrown design without ferrule and 2 mm inlay depth showed the lowest surface gap. The pulpal surface showed the highest discrepancy among all groups compared to the other surfaces. Endocrowns without ferrule are more conservative and have higher fracture strength than 1 mm ferrule designs; extending the inlay depth showed a significant increase in fracture resistance of the 1 mm ferrule design, but not for the conventional design without ferrule and 2 mm inlay depth. All groups exhibited a high auspicious fracture strength value for molar endocrown restorations. Full article
(This article belongs to the Special Issue Ceramic Dental Restorations: From Materials Sciences to Applications)
Show Figures

Figure 1

12 pages, 5134 KiB  
Article
Impact of CAD/CAM Material Thickness and Translucency on the Polymerization of Dual-Cure Resin Cement in Endocrowns
by Soshi Ikemoto, Yuya Komagata, Shinji Yoshii, Chihiro Masaki, Ryuji Hosokawa and Hiroshi Ikeda
Polymers 2024, 16(5), 661; https://doi.org/10.3390/polym16050661 - 29 Feb 2024
Cited by 5 | Viewed by 1871
Abstract
The objective of this study is to evaluate the impact of the thickness and translucency of various computer-aided design/computer-aided manufacturing (CAD/CAM) materials on the polymerization of dual-cure resin cement in endocrown restorations. Three commercially available CAD/CAM materials—lithium disilicate glass (e.max CAD), resin composite [...] Read more.
The objective of this study is to evaluate the impact of the thickness and translucency of various computer-aided design/computer-aided manufacturing (CAD/CAM) materials on the polymerization of dual-cure resin cement in endocrown restorations. Three commercially available CAD/CAM materials—lithium disilicate glass (e.max CAD), resin composite (CERASMART), and a polymer-infiltrated ceramic network (ENAMIC)—were cut into plates with five different thicknesses (1.5, 3.5, 5.5, 7.5, and 9.5 mm) in both high-translucency (HT) and low-translucency (LT) grades. Panavia V5, a commercial dual-cure resin cement, was polymerized through each plate by light irradiation. Post-polymerization treatment was performed by aging at 37 °C for 24 h under light-shielding conditions. The degree of conversion and Vickers hardness measurements were used to characterize the polymerization of the cement. The findings revealed a significant decrease in both the degree of conversion and Vickers hardness with increasing thickness across all CAD/CAM materials. Notably, while the differences in the degree of conversion and Vickers hardness between the HT and LT grades of each material were significant immediately after photoirradiation, these differences became smaller after post-polymerization treatment. Significant differences were observed between samples with a 1.5 mm thickness (conventional crowns) and those with a 5.5 mm or greater thickness (endocrowns), even after post-polymerization treatment. These results suggest that dual-cure resin cement in endocrown restorations undergoes insufficient polymerization. Full article
(This article belongs to the Special Issue Advances in Polymeric Dental Materials)
Show Figures

Figure 1

16 pages, 3234 KiB  
Article
Influence of Cementation Mode and Ferrule Design on the Fatigue Resistance of Monolithic Zirconia Endocrowns
by Milan Stoilov, Tobias Boehmer, Lea Stoilov, Helmut Stark, Michael Marder, Norbert Enkling and Dominik Kraus
J. Clin. Med. 2024, 13(4), 1165; https://doi.org/10.3390/jcm13041165 - 19 Feb 2024
Cited by 2 | Viewed by 2409
Abstract
Background: Classic endocrowns made of dental ceramics are considered a promising alternative to traditional post-endodontic restorations. The use of circular ferrules in endocrowns is a topic of controversial discussion. Therefore, the present study aims to evaluate the effect of ferrule design and [...] Read more.
Background: Classic endocrowns made of dental ceramics are considered a promising alternative to traditional post-endodontic restorations. The use of circular ferrules in endocrowns is a topic of controversial discussion. Therefore, the present study aims to evaluate the effect of ferrule design and cementation mode on the fatigue resistance of zirconia endocrowns. Methods: Eighty human molars were divided into four groups (n = 20): NFC (no-ferrule, conventional cementation), NFA (no-ferrule, adhesive luting), FC (ferrule, conventional cementation) and FA (ferrule, adhesive luting). Both the classic and the modified endocrown preparation with a two-millimeter ferrule design were carried out. Endocrowns were fabricated from zirconia using the CEREC system. After thermocycling, specimens were loaded according to the step-stress test up to 1500 N. Results: Failure rate was low; 88.8% of total specimens passed the step-stress test. Fractures were distributed between all groups; no significant differences in fatigue resistance were detected for preparation design and cementation mode. Conclusions: Endocrowns appear to be a promising concept for endodontically treated molars. Ferrule and also cementation mode have only a minor influence on fatigue resistance of zirconia endocrowns. However, at very high forces, the marginal area of the ferrule represents a weak point. Full article
(This article belongs to the Special Issue Modern Patient-Centered Dental Care)
Show Figures

Graphical abstract

13 pages, 3478 KiB  
Article
The Effect of Different Ferrule Configurations and Preparation Designs on the Fatigue Performance of Endodontically Treated Maxillary Central Incisors: A 3D Finite Element Analysis
by Mehmet Gökberkkaan Demirel and Reza Mohammadi
Appl. Sci. 2024, 14(4), 1355; https://doi.org/10.3390/app14041355 - 7 Feb 2024
Cited by 3 | Viewed by 2583
Abstract
The presence of an adequate circumferential ferrule is of great importance for the prosthetic rehabilitation of endodontically treated teeth. However, there may not be an adequate circumferential ferrule effect. This study aimed to evaluate the fatigue performance of endocrown and post–core restorations applied [...] Read more.
The presence of an adequate circumferential ferrule is of great importance for the prosthetic rehabilitation of endodontically treated teeth. However, there may not be an adequate circumferential ferrule effect. This study aimed to evaluate the fatigue performance of endocrown and post–core restorations applied to different configurations without an adequate ferrule effect using the finite element method and endeavors to offer a comprehensive perspective on the challenging rehabilitation of maxillary incisors with excessive coronal substance loss, addressing a notable gap in research and providing valuable insights for clinicians. The goal is to address this gap in research and contribute valuable insights that could be beneficial for practitioners. The maxillary central incisor was selected, and lithium disilicate (LS) and a polymer-infiltrated ceramic network (PICN) were used in post–core groups with no ferrule effect (PC0); a 2 mm ferrule effect on the buccal wall (PC1); a 2 mm ferrule effect on the buccal-mesial wall (PC2); a 2 mm ferrule effect on the buccal–mesial–palatal wall (PC3); and a 2 mm circumferential ferrule effect (PC4) In the endocrown groups, an external retention group with a circumferential ferrule (ECER) and an inner retention form group (ECIR) were prepared. Fatigue performance was examined by applying a 150 N oblique load. The evaluation of the fatigue performance of the restorative materials shows that LS always had more successful fatigue performance results, while the post–core groups were generally more successful in terms of dentin survival. In situations where there is insufficient circumferential ferrule, the application of endocrowns is likely to result in a less successful prognosis for survival. Full article
(This article belongs to the Special Issue Digital Dentistry and New Era of Prosthodontics)
Show Figures

Figure 1

16 pages, 3143 KiB  
Article
Biomechanical Behavior of Lithium-Disilicate-Modified Endocrown Restorations: A Three-Dimensional Finite Element Analysis
by Fatien I. Al-naqshabandi, Bahar Jaafar Selivany and Abdulsalam Rasheed Al-zahawi
Ceramics 2023, 6(4), 2162-2177; https://doi.org/10.3390/ceramics6040133 - 11 Nov 2023
Cited by 1 | Viewed by 2784
Abstract
This study aimed to assess the biomechanical behavior of endocrown-restored mandibular molars according to “margin design” and “coverage extent” using finite element analysis (FEA). Six 3D solid models were fabricated, namely, those with complete occlusal coverage: A (butt joint), B (anatomic margin); partial [...] Read more.
This study aimed to assess the biomechanical behavior of endocrown-restored mandibular molars according to “margin design” and “coverage extent” using finite element analysis (FEA). Six 3D solid models were fabricated, namely, those with complete occlusal coverage: A (butt joint), B (anatomic margin); partial coverage (two mesial cusps): C (butt joint), D (anatomic margin); and partial coverage with mesial class II cavity: E (butt joint), F (anatomic margin). All models received lithium disilicate endocrowns (2.0 mm thickness and 4.0 mm central retainer cavity depth). A 300 N vertical load was applied to the occlusal surface, while a 250 N oblique load was applied at 45° to the lingual inclined planes of the buccal cusps. The maximum von Mises stress (VMS) distribution patterns were calculated for the endocrown, tooth structure, and cement layer. The VMS on the prepared teeth and cement layer showed subtle differences between the tested models under vertical loads. The anatomic margin (partial and complete coverage) exhibited a more homogeneous stress distribution and offered a more adhesive area of the tooth structure. Under oblique loading, the anatomic margin (complete and partial), except Model D, exhibited the lowest VMS in the cement layer. An anatomically based endocrown could be a promising alternative to the butt joint design, providing better-devised endocrown restorations, which could potentially yield a more benign stress dissipation. Full article
(This article belongs to the Special Issue Ceramic Materials in Oral Applications)
Show Figures

Figure 1

15 pages, 1712 KiB  
Article
In Vitro Resistance of Natural Molars vs. Additive-Manufactured Simulators Treated with Pulpotomy and Endocrown
by Marie-Laure Munoz-Sanchez, Alexis Gravier, Olivier Francois, Emmanuel Nicolas, Martine Hennequin and Nicolas Decerle
J. Funct. Biomater. 2023, 14(9), 444; https://doi.org/10.3390/jfb14090444 - 29 Aug 2023
Viewed by 1861
Abstract
Endocrowns are designed to restore endodontically treated teeth with root canal treatment (Rct). Recently, endocrowns were proposed for teeth treated with full pulpotomy (FP). No data exist on in vitro evaluations for this combination. This study aimed to evaluate the mechanical behavior of [...] Read more.
Endocrowns are designed to restore endodontically treated teeth with root canal treatment (Rct). Recently, endocrowns were proposed for teeth treated with full pulpotomy (FP). No data exist on in vitro evaluations for this combination. This study aimed to evaluate the mechanical behavior of pulpotomy-treated teeth with endocrowns according to different protocols for preparation design and materials and to assess whether 3D-printed resin simulators could be a reliable alternative for human teeth during in vitro strength tests. One hundred and ten extracted natural molars were randomized into 11 groups according to the type of endodontic treatment, the material used, and the design of peripheric preparation. One hundred and ten resin simulators were separated similarly. The samples were embedded in epoxy resin blocks before being subjected to oblique compressive load until failure. For natural teeth, the variance analysis separated two homogeneous groups, one regrouping the endodontically treated or pulpotomy-treated teeth without coronal restoration and the other one regrouping all the other samples, i.e., the untreated teeth (positive controls) and the treated and restored teeth. The strength resistance was lower for the resin simulators than for natural teeth in all groups. Within the limit of this study, strength resistance is not the most important criterion for choosing the type of material, preparation, or endodontic treatment for endocrowns. Resin simulators are not efficient for in vitro strength studies. Full article
(This article belongs to the Special Issue Additive Manufacturing of Dental Materials)
Show Figures

Figure 1

14 pages, 5396 KiB  
Article
In-Vitro Comparison of Fracture Strength of Endocrowns and Overlays in Endodontically Treated Teeth Manufactured with Monolithic Lithium Disilicate and Zirconia
by Maya Veselinova, Sofia Diamantopoulou, Chariklia Paximada and Efstratios Papazoglou
J. Funct. Biomater. 2023, 14(8), 422; https://doi.org/10.3390/jfb14080422 - 11 Aug 2023
Cited by 8 | Viewed by 4970
Abstract
To evaluate the fracture strength and the failure mode of endodontically treated molars restored with monolithic lithium disilicate and zirconia endocrowns and overlays. A total of 48 extracted mandibular molars were endodontically treated, decoronated 2 mm above the cementoenamel junction and divided into [...] Read more.
To evaluate the fracture strength and the failure mode of endodontically treated molars restored with monolithic lithium disilicate and zirconia endocrowns and overlays. A total of 48 extracted mandibular molars were endodontically treated, decoronated 2 mm above the cementoenamel junction and divided into four 12-specimen groups. Group ELD: lithium disilicate endocrowns. Group EZ: monolithic zirconia endocrowns. Group OLD: lithium disilicate overlays. Group OZ: monolithic zirconia overlays. Overlays did not extend in the pulp chamber and endocrowns extended in the pulp chamber 2 mm. After adhesive bonding of the restorations, the specimens were subjected to thermocycling (×5000 cycles) and then to fracture resistance testing at lateral static loading (1 mm/min) at a universal testing machine. The failure mode of the specimens was qualitatively evaluated. Differences in means were compared using with t-tests for independent samples or Mann–Whitney test (p < 0.05). Weibull distribution analysis was also performed. Group ELD showed significantly higher fracture strength than all other groups (p = 0.001), and the highest Weibull modulus. Conclusions: Lithium disilicate endocrowns exhibit higher fracture strength and are more reliable compared to the other types of restorations examined. Endocrowns had more catastrophic failures compared to overlays. Full article
(This article belongs to the Special Issue Biomaterials in Conservative Dentistry and Prosthodontics)
Show Figures

Figure 1

Back to TopTop