Sign in to use this feature.

Years

Between: -

Subjects

remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline

Journals

Article Types

Countries / Regions

Search Results (48)

Search Parameters:
Keywords = denture reinforcement

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
33 pages, 405 KB  
Review
Contemporary Use of Polymers in Dentistry: A Narrative Review
by Svetla Ivanova, Zlatina Tomova, Angelina Vlahova, Iliyana L. Stoeva, Elena Vasileva, Yordanka Uzunova, Magdalina Urumova, Desislav Tomov and Atanas Chonin
Polymers 2026, 18(1), 138; https://doi.org/10.3390/polym18010138 - 2 Jan 2026
Viewed by 799
Abstract
This narrative review examines contemporary applications of polymeric materials in dentistry from 2020 to 2025, spanning prosthodontics, restorative dentistry, orthodontics, endodontics, implantology, diagnostics, and emerging technologies. We searched PubMed, Scopus, Web of Science, and Embase for peer reviewed English language articles and synthesized [...] Read more.
This narrative review examines contemporary applications of polymeric materials in dentistry from 2020 to 2025, spanning prosthodontics, restorative dentistry, orthodontics, endodontics, implantology, diagnostics, and emerging technologies. We searched PubMed, Scopus, Web of Science, and Embase for peer reviewed English language articles and synthesized evidence on polymer classes, processing routes, mechanical and chemical behavior, and clinical performance. Approximately 116 articles were included. Polymers remain central to clinical practice: poly methyl methacrylate (PMMA) is still widely used for dentures, high performance systems such as polyether ether ketone (PEEK) are expanding framework and implant-related indications, and resin composites and adhesives continue to evolve through nanofillers and bioactive formulations aimed at improved durability and reduced secondary caries. Thermoplastic polyurethane and copolyester systems drive clear aligner therapy, while polymer-based obturation materials and fiber-reinforced posts support endodontic rehabilitation. Additive manufacturing and computer aided design computer aided manufacturing (CAD CAM) enable customized prostheses and surgical guides, and sustainability trends are accelerating interest in biodegradable or recyclable dental polymers. Across domains, evidence remains heterogeneous and clinical translation depends on balancing strength, esthetics, biocompatibility, aging behavior, and workflow constraints. Full article
(This article belongs to the Special Issue Polymers Strategies in Dental Therapy)
28 pages, 858 KB  
Review
Fiber-Reinforced Composites in Fixed Prosthodontics: A Comprehensive Overview of Their Historical Development, Types, Techniques, and Longevity
by Muhammad Amber Fareed, Mazen Abdulmounem Masri, Almustafa Wisam Mustafa Al-sammarraie and Buthena Mohamed Ehsan Akil
Prosthesis 2025, 7(6), 139; https://doi.org/10.3390/prosthesis7060139 - 3 Nov 2025
Cited by 2 | Viewed by 2310
Abstract
Background: Fiber-reinforced composites (FRCs) have emerged as transformative materials in restorative dentistry, particularly for managing partial edentulism through fixed partial dentures (FPDs). Their superior aesthetic, mechanical, and adhesive properties offer a minimally invasive alternative to traditional metal–ceramic restorations. Objective: This review aims [...] Read more.
Background: Fiber-reinforced composites (FRCs) have emerged as transformative materials in restorative dentistry, particularly for managing partial edentulism through fixed partial dentures (FPDs). Their superior aesthetic, mechanical, and adhesive properties offer a minimally invasive alternative to traditional metal–ceramic restorations. Objective: This review aims to evaluate the historical evolution, clinical applications, technological advancements, and prospects of FRCs in prosthodontics, emphasizing their potential to deliver durable, aesthetic, and cost-effective treatment solutions. Methods: This narrative review follows the SANRA guidelines. A comprehensive literature search was conducted across PubMed, ScienceDirect, and Google Scholar for studies published between January 1995 and January 2025. Search terms included “fiber-reinforced composite”, “fixed prosthodontics”, “fixed partial dentures”, “adhesive restorations”, and “implant-supported restorations”. Only English-language studies addressing the clinical applications, mechanical properties, technological innovations, or survival outcomes of FRCs were included. Data were extracted from original research papers, systematic reviews, and narrative reviews. Results: Advancements in fiber architecture, resin matrices, and polymerization techniques have enhanced the strength, aesthetics, and longevity of FRC-based FPDs. Their high flexural strength, fatigue resistance, and compatibility with adhesive restorative techniques provide clinicians with versatile treatment options. Clinical studies demonstrate favorable survival rates and long-term success, positioning FRC FDPs as reliable alternatives to conventional restorations. Emerging technologies such as CAD/CAM and 3D printing further broaden their scope and precision. Conclusions: FRC FPDs have evolved from interim solutions to predictable, long-term restorations. With ongoing technological innovations and clinical validation, they are poised to become a mainstream treatment choice in prosthodontics. FRC FPDs offer a durable, aesthetic, and cost-effective solution aligned with minimally invasive dentistry, reducing tooth preparation while improving patient-centered outcomes. Full article
(This article belongs to the Section Prosthodontics)
Show Figures

Figure 1

13 pages, 13548 KB  
Article
The Effectiveness of Phosphate-Based Bioactive Glass on Candida albicans Adherence in Dental Soft Lining Material (In Vitro Study)
by Nada Hussien Ielewi and Faiza M. Abdul-Ameer
Hygiene 2025, 5(4), 49; https://doi.org/10.3390/hygiene5040049 - 21 Oct 2025
Viewed by 724
Abstract
Background: Denture stomatitis (DS) represents an oral fungal infection induced by Candida albicans, impacting approximately 70% of the individuals who use removable acrylic dentures. Researchers suggest that the high level of the Candida species, particularly Candida albicans (C. albicans), is the [...] Read more.
Background: Denture stomatitis (DS) represents an oral fungal infection induced by Candida albicans, impacting approximately 70% of the individuals who use removable acrylic dentures. Researchers suggest that the high level of the Candida species, particularly Candida albicans (C. albicans), is the predominant etiological factor of DS. Consequently, the development of a soft liner with antifungal activity might significantly enhance its therapeutic applicability. This in vitro study evaluates the impact of phosphate bioactive glass reinforced heat-cured acrylic-based soft liner on the candidal activity in this material. Method: Specimens (10 mm × 2 mm disc-like) were required for the selected test; PBG-Sr nano-powder was synthesized and added to the soft liner at percentages of 1 wt.%, 3 wt.%, 5 wt.%, and 7 wt.%. The candidal adherence test was investigated, and characterization was performed by X-ray diffraction analysis, field emission scanning electron microscopy, energy dispersive X-ray spectroscopy mapping, and particle size analysis. The resulting data were analyzed with one-way ANOVA followed by Dunnett’s test. Results: Candidal adherence in the 1 wt.%, 3 wt.%, 5 wt.%, and 7 wt.% PBG-Sr subgroups had decreased values in comparison to the control (0 wt.%), with the 7 wt.% subgroup demonstrating the lowest count of C. albicans (0.027), close to the nystatin group. Conclusions: PBG-Sr can diminish C. albicans adhesion in soft lining materials, and a soft liner containing PBG-Sr (7 wt.%) showed the most effective activity against C. albicans in the soft liner. Soft liners infused with bioactive glass may have the potential to assist those struggling with denture stomatitis, providing patients with enhanced therapeutic qualities. Full article
(This article belongs to the Section Oral and Dental Hygiene)
Show Figures

Figure 1

16 pages, 1215 KB  
Article
Effect of Acidic Environment and Tooth Brushing on the Color and Translucency of 3D-Printed Ceramic-Reinforced Composite Resins for Indirect Restorations and Hybrid Prostheses
by Sarah M. Alnafaiy, Nawaf Labban, Alhanoof Saleh Aldegheishem, Saleh Alhijji, Refal Saad Albaijan, Saad Saleh AlResayes, Rafa Abdulrahman Alsultan, Abeer Mohammed Alrossais and Rahaf Farhan Alanazi
Polymers 2025, 17(20), 2772; https://doi.org/10.3390/polym17202772 - 16 Oct 2025
Viewed by 940
Abstract
This study evaluated the effect of acidic environment and tooth brushing on the color stability and translucency of stained 3D-printed ceramic-reinforced composite (CRC) resins for indirect restorations and hybrid prostheses. Twelve specimens were prepared from each 3D-printing resin material: Ceramic Crown (CC), OnX [...] Read more.
This study evaluated the effect of acidic environment and tooth brushing on the color stability and translucency of stained 3D-printed ceramic-reinforced composite (CRC) resins for indirect restorations and hybrid prostheses. Twelve specimens were prepared from each 3D-printing resin material: Ceramic Crown (CC), OnX (ONX), and Tough 2 (T2), and one CAD/CAM milling resin, Lava Ultimate (LU). After preparation, all specimens were stained, then immersed in either water or citric acid. Subsequently, the specimens underwent simulated tooth brushing for 3650 cycles. Color stability (ΔE) and translucency parameter (TP) were measured using a spectrophotometer. Data were analyzed using ANOVA, post hoc Tukey tests, and independent Student t-tests (α = 0.05). Material type, immersion medium, and their interaction did not significantly influence the mean ΔE (p > 0.05). The lowest ΔE value was for LU in acid (ΔE = 1.11 ± 0.39), and the highest for T2 in water (ΔE = 2.09 ± 1.47). Except for ONX and LU in acid, all materials had ΔE values above the perceptibility threshold (ΔE = 1.2). The mean TP was significantly affected by material type, immersion medium, and their interaction (p < 0.05). The lowest TP value was for group CC in acid (0.91 ± 0.26); the highest was for group LU in acid (6.24 ± 0.56). After immersion and subsequent tooth brushing, TP values decreased for all materials. Exposure to an acidic environment and tooth brushing did not affect color stability but significantly reduced translucency. Both the 3D-printed CRCs and milled resin material displayed comparable color stability below clinically acceptable thresholds, though the translucency of 3D-printed materials remained lower compared to milled material. Full article
(This article belongs to the Special Issue Polymers in Restorative Dentistry: 2nd Edition)
Show Figures

Figure 1

12 pages, 2705 KB  
Article
Electrochemical Behavior of Cobalt–Chromium Alloy Exposed to Effervescent Denture Cleansers
by Glenda Lara Lopes Vasconcelos, Carolina Alves Freiria de Oliveira, Ana Paula Macedo, Viviane de Cássia Oliveira, Patrícia Almeida Curylofo, Carlos Alberto Della Rovere, Rodrigo Galo, Bruna S. H. Tonin and Valéria Oliveira Pagnano
Corros. Mater. Degrad. 2025, 6(2), 23; https://doi.org/10.3390/cmd6020023 - 12 Jun 2025
Viewed by 1683
Abstract
This study demonstrates that effervescent denture cleansers can influence the electrochemical behavior of cobalt–chromium (Co-Cr) alloys, with a particular focus on their corrosion resistance. The findings underscore the importance for dental professionals of selecting cleansers compatible with Co-Cr prostheses to minimize material degradation [...] Read more.
This study demonstrates that effervescent denture cleansers can influence the electrochemical behavior of cobalt–chromium (Co-Cr) alloys, with a particular focus on their corrosion resistance. The findings underscore the importance for dental professionals of selecting cleansers compatible with Co-Cr prostheses to minimize material degradation and enhance clinical durability. Corrosion resistance was evaluated using open-circuit potential (OCP), corrosion current density (icorr), and passivation current density (ipass). Surface morphology and elemental composition were analyzed through scanning electron microscopy (SEM) and energy-dispersive X-ray spectroscopy (EDS). Forty specimens (n = 5 per group) were individually immersed in one of ten test solutions: distilled water (DW), artificial saliva (AS), and eight commercial denture cleansers—Polident 3 minutes™ (P3M), Steradent™ (St), Polident for Partials™ (PP), Efferdent™ (Ef), Corega Tabs™ (CT), NitrAdine™ (Ni), Fixodent™ (Fi), and Kukident™ (Ku). Each specimen was exposed a single solution to avoid cross-contamination. Results showed St, Ef, and Ku had higher OCP values than DW and Ni (p < 0.05), indicating better corrosion resistance. AS exhibited lower OCP values compared to St (p = 0.034), Ku (p = 0.023), and P3M (p = 0.050). DW had higher icorr than PP (p = 0.030), CT (p = 0.005), and P3M (p = 0.003). For ipass, DW had lower values than Ef (p = 0.025) and Ku (p = 0.016). SEM and EDS revealed no significant surface alterations. Understanding the underlying corrosion mechanisms in different solutions provides valuable insights into optimizing material performance and ensuring durability in clinical applications. The corrosion resistance of Co-Cr depends on the stability of the passive oxide layer, which can be degraded by chloride ions, reinforced by sulfate ions, and influenced by active ingredients in denture cleansers. Overall, the Co-Cr alloy demonstrated acceptable corrosion resistance, underscoring the importance of selecting suitable cleansers for prosthesis longevity. Full article
(This article belongs to the Special Issue Advances in Material Surface Corrosion and Protection)
Show Figures

Graphical abstract

17 pages, 8724 KB  
Article
Thermal Stress Analysis of Maxillary Dentures with Different Reinforcement Materials Under Occlusal Load Using Finite Element Method
by Semih Benli and Gökhan Baş
Appl. Sci. 2024, 14(22), 10271; https://doi.org/10.3390/app142210271 - 8 Nov 2024
Cited by 1 | Viewed by 1427
Abstract
The purpose of this study was to determine the effect of fiber reinforcement materials on the magnitude of stresses in a critical part of the maxillary denture base under thermal and occlusal load. Thermal stress analyses of the models were carried out using [...] Read more.
The purpose of this study was to determine the effect of fiber reinforcement materials on the magnitude of stresses in a critical part of the maxillary denture base under thermal and occlusal load. Thermal stress analyses of the models were carried out using the finite element method. The models consisted of bone, soft tissue, interface gap, and maxillary dentures with and without reinforcements. A concentrated occlusal load of 230 N was applied bilaterally on the molar teeth. A 36 °C reference and 0 °C, 36 °C, and 70 °C variable ambient temperatures were applied to the models. CrCo, unidirectional and woven carbon/epoxy, unidirectional and woven glass/epoxy, and unidirectional and woven Kevlar/epoxy were used as reinforcing materials in the maxillary denture base made of PMMA (polymethyl methacrylate). Stress distributions on the maxillary denture’s midline and lateral line direction were evaluated. Maximum stresses in the incisal notch and the labial frenal notch of the maxillary denture were determined. Failure analysis of reinforcement materials used in maxillary dentures was carried out using the Tsai-Wu index criterion. The results obtained show that the thermal properties of reinforcement materials should be considered as an important criterion in their selection. Full article
(This article belongs to the Section Applied Thermal Engineering)
Show Figures

Figure 1

14 pages, 4314 KB  
Article
The Effect of the Incorporation of a 3D-Printed Titanium Framework on the Mechanical Properties CAD/CAM Denture Base Materials
by Rafael Delgado-Ruiz, Ido Brintouch, Aisha Ali, Yiwei Fang, Georgios Romanos and Miriam Rafailovich
Prosthesis 2024, 6(4), 753-766; https://doi.org/10.3390/prosthesis6040053 - 10 Jul 2024
Cited by 3 | Viewed by 2974
Abstract
Background: Complete dentures should withstand occlusal forces and wear. However, over time, dentures can suffer fatigue and develop cracks, chipping, and fractures. Conventional methods for the fabrication of complete dentures involve injection molding, thermal curing, and the use of microwaves with polymethyl methacrylate [...] Read more.
Background: Complete dentures should withstand occlusal forces and wear. However, over time, dentures can suffer fatigue and develop cracks, chipping, and fractures. Conventional methods for the fabrication of complete dentures involve injection molding, thermal curing, and the use of microwaves with polymethyl methacrylate (PMMA)-based materials. These methods have served well for many years. More recently, the incorporation of computer-aided design and computer-aided manufacturing (CAD/CAM) to fabricate complete dentures has been shown to enhance the dentures’ mechanical properties, including resistance to wear and impact strength. This study aims to investigate the mechanical properties and fracture types of CAD/CAM denture base materials (both milled and printed) as compared to a novel proprietary method that embeds a 3D-printed framework within PMMA-milled blocks. The null hypothesis is that incorporating a 3D-printed framework does not affect the mechanical properties of milled PMMA blocks. Methods: Three groups of bars were fabricated using CAD/CAM methods: printed (P), milled (M), and milled with a 3D-printed metallic framework reinforcement (M + F). A three-point bending test evaluated deformation, followed by an impact fracture test for fracture toughness. A descriptive fractographic analysis assessed the fracture characteristics. A statistical analysis using a paired t-test compared the differences between the groups. Results: The P group showed more elastic deformation than the M and M + F groups (p < 0.05). The M + F group achieved a higher fracture toughness as compared to the M and P groups (p < 0.05). Conclusions: Within the limitations of this experimental study, the null hypothesis can be rejected. Milled samples with an embedded 3D-printed titanium framework possess higher resistance to impact than milled samples without frameworks, and printed samples and milled samples with embedded 3d-printed titanium frameworks present increased flexural strength and lower elastic deformation as compared to milled samples without frameworks and printed samples. Full article
Show Figures

Figure 1

19 pages, 2803 KB  
Article
Exploring Flexural Strength Variation in Polymeric Materials for Provisional Fixed Prosthetic Structures: Comparative Analysis with and without Reinforcement through Laboratory Experimentation and Statistical Evaluation
by Mariana Dimova-Gabrovska, Todor Uzunov, Angela Gusiyska, Dobromira Shopova, Iva Taneva, Ivan Gerdzhikov and Stefan Rangelov
Appl. Sci. 2024, 14(9), 3923; https://doi.org/10.3390/app14093923 - 4 May 2024
Cited by 3 | Viewed by 2013
Abstract
Provisional fixed partial dentures represent a critical phase in dental treatment, necessitating heightened mechanical durability, particularly in comprehensive and extended treatment plans. Strengthening these structures with various reinforcing materials offers a method to enhance their resilience. Utilizing a three-point testing methodology on standardized [...] Read more.
Provisional fixed partial dentures represent a critical phase in dental treatment, necessitating heightened mechanical durability, particularly in comprehensive and extended treatment plans. Strengthening these structures with various reinforcing materials offers a method to enhance their resilience. Utilizing a three-point testing methodology on standardized trial specimens allows for a comparative assessment of various materials and reinforcement techniques for pre-prosthetic applications. This study aims to validate and assess the significance of integrating different reinforcing materials into standardized test bodies. The study focuses on test specimens comprising three types of unreinforced laboratory and clinical polymers for provisional constructions (n = 6)—heat-cured PMMA (Superpont C+B, Spofa Dental, Czech Republic), CAD-CAM prefabricated PMMA (DD temp MED, Dental Direkt, Germany), CAD-CAM printing resin (Temporary CB Resin, FormLabs, USA), self-polymerizing PEMA (DENTALON plus, Kulzer, Germany), light-polymerizing composite (Revotek LC, GC, Japan), and dual-polymerizing composite (TempSpan, Pentron, USA). Additionally, laboratory polymers are evaluated in groups with five types of reinforcing filaments (n = 15)—Glass Fiber (Fiber Splint One-Layer, Polydentia, Switzerland), Polyethylene thread (Ribbond Regular 4.0 mm, Ribbond Inc., USA), triple-stranded chrome-cobalt wire for splinting 015″ (Leone S.p.a., Italy), Aesthetic ligature wire 012″ (Leone S.p.a., Italy), and Glass Fiber coated with light-cured composite 8.5 × 0.2 mm (Interlig, Angelus, Brazil). Analysis of the data using Generalized Linear Models (GLMs) reveals that the experimental bodies, produced via the subtractive digital method using PMMA (DD temp MED, Dental Direkt GmbH, Germany) as the polymer and glass filaments as the reinforcement, exhibit superior mechanical properties, particularly when pre-wetted with Interlig liquid composite (Angelus, Brazil). Full article
(This article belongs to the Section Applied Dentistry and Oral Sciences)
Show Figures

Figure 1

15 pages, 8168 KB  
Article
Evaluating the Translucency, Surface Roughness, and Cytotoxicity of a PMMA Acrylic Denture Base Reinforced with Bioactive Glasses
by Abdulaziz Alhotan, Zbigniew Raszewski, Katarzyna Chojnacka, Marcin Mikulewicz, Julita Kulbacka, Razan Alaqeely, Amani Mirdad and Julfikar Haider
J. Funct. Biomater. 2024, 15(1), 16; https://doi.org/10.3390/jfb15010016 - 31 Dec 2023
Cited by 4 | Viewed by 3140
Abstract
The colonisation of the surface of removable acrylic dentures by various types of microorganisms can lead to the development of various diseases. Therefore, the creation of a bioactive material is highly desirable. This study aimed to develop a denture base material designed to [...] Read more.
The colonisation of the surface of removable acrylic dentures by various types of microorganisms can lead to the development of various diseases. Therefore, the creation of a bioactive material is highly desirable. This study aimed to develop a denture base material designed to release bioactive ions into the oral environment during use. Four types of bioactive glasses (BAG)—S53P4, Biomin F, 45S5, and Biomin C—were incorporated into the PMMA acrylic resin, with each type constituting 20 wt.% (10 wt.% non-silanised and 10% silanised) of the mixture, while PMMA acrylic resin served as the control group. The specimens were subsequently immersed in distilled water, and pH measurements of the aqueous solutions were taken every seven days for a total of 38 days. Additionally, surface roughness and translucency measurements were recorded both after preparation and following seven days of immersion in distilled water. The cytotoxicity of these materials on human fibroblast cells was evaluated after 24 and 48 h using Direct Contact and MTT assays. Ultimately, the elemental composition of the specimens was determined through energy-dispersive X-ray (EDX) spectroscopy. In general, the pH levels of water solutions containing BAG-containing acrylics gradually increased over the storage period, reaching peak values after 10 days. Notably, S53P4 glass exhibited the most significant increase, with pH levels rising from 5.5 to 7.54. Surface roughness exhibited minimal changes upon immersion in distilled water, while a slight decrease in material translucency was observed, except for Biomin C. However, significant differences in surface roughness and translucency were observed among some of the BAG-embedded specimens under both dry and wet conditions. The composition of elements declared by the glass manufacturer was confirmed by EDX analysis. Importantly, cytotoxicity analysis revealed that specimens containing BAGs, when released into the environment, did not adversely affect the growth of human gingival fibroblast cells after 48 h of exposure. This suggests that PMMA acrylics fabricated with BAGs have the potential to release ions into the environment and can be considered biocompatible materials. Further clinical trials are warranted to explore the practical applications of these materials as denture base materials. Full article
(This article belongs to the Special Issue Bioactive Glasses and Their Multiple Applications in Biomedicine)
Show Figures

Figure 1

11 pages, 7274 KB  
Technical Note
Computer Aided Full Arch Restoration by Means of One-Piece Implants and Stackable Guide: A Technical Note
by Mattia Manfredini, Pier Paolo Poli, Carlo Maiorana, Federica Eugenia Salina, Marco Tandurella and Mario Beretta
Dent. J. 2023, 11(11), 256; https://doi.org/10.3390/dj11110256 - 1 Nov 2023
Cited by 8 | Viewed by 4269
Abstract
This technical note aims to present a recently developed computer-guided protocol characterized by titanium-reinforced stackable surgical guides during post-extractive implant placement and subsequent immediate loading. A full maxillary edentulism was rehabilitated with one-piece implants, starting from a pre-existing removable denture. 3D digital scans [...] Read more.
This technical note aims to present a recently developed computer-guided protocol characterized by titanium-reinforced stackable surgical guides during post-extractive implant placement and subsequent immediate loading. A full maxillary edentulism was rehabilitated with one-piece implants, starting from a pre-existing removable denture. 3D digital scans of the removable denture and upper and lower arches were performed. On this basis, a prototype with ideal esthetic and functional outcomes was realized and replicated into a custom-made radiological stent with markers. The superimposition of STL and DICOM files allowed virtual planning of one-piece implants in the ideal prosthetically driven position. The stackable guides, composed of a fixed base template and additional removable components, were then realized. The fixed template, initially secured with anchor pins to the bone, was no longer removed. The removable components, which were screwed to the base template, were used to perform implant surgery and immediate prosthetic loading. No surgical complications occurred, the implants achieved a minimum insertion torque of 35 Ncm, and immediate prosthetic loading was performed. The base template allowed for the maintenance of a fixed reference during the entire workflow, improving the transition between the digital project, the surgical procedure, and the prosthetic rehabilitation. Full article
(This article belongs to the Special Issue Oral Implantology and Rehabilitation)
Show Figures

Figure 1

9 pages, 1090 KB  
Article
An Experimental Method to Add New Prosthetic Teeth in the Removable Partial Denture Framework: TIG Cold Welding and Preformed Pins
by Enzo Cumbo, Pietro Messina, Giuseppe Gallina and Giuseppe Alessandro Scardina
Prosthesis 2023, 5(4), 1120-1128; https://doi.org/10.3390/prosthesis5040078 - 31 Oct 2023
Cited by 5 | Viewed by 2119
Abstract
The need to modify removable partial dentures equipped with a metal framework in order to add other prosthetic teeth to replace natural teeth lost by the patient could lead to laboratory procedures so complex as to require the creation of new prostheses with [...] Read more.
The need to modify removable partial dentures equipped with a metal framework in order to add other prosthetic teeth to replace natural teeth lost by the patient could lead to laboratory procedures so complex as to require the creation of new prostheses with a heavy economic burden. The creation of preformed metal pins to be welded using the economical TIG cold welding method could represent a valid alternative solution with the aim of modifying the prostheses using a reinforced resin capable of adequately resisting masticatory loads. This study evaluates and compares the mechanical robustness and the clinical reliability of these modified prostheses in cases of junctions of one or two contiguous prosthetic teeth. The 6-month follow-up demonstrated the total validity of the method via the absence of significant breakages or detachments in all of the patients analyzed; on the other hand, the prostheses modified using the traditional method and used as controls showed a high incidence of fractures. Full article
(This article belongs to the Special Issue Innovative Prosthetic Devices Applied to the Human Body)
Show Figures

Figure 1

27 pages, 3218 KB  
Review
Polymeric Denture Base Materials: A Review
by Ahmed Yaseen Alqutaibi, Abdulmajeed Baik, Sarah A. Almuzaini, Ahmed E. Farghal, Ahmad Abdulkareem Alnazzawi, Sary Borzangy, Afaf Noman Aboalrejal, Mohammed Hosny AbdElaziz, Ihab Ismail Mahmoud and Muhammad Sohail Zafar
Polymers 2023, 15(15), 3258; https://doi.org/10.3390/polym15153258 - 31 Jul 2023
Cited by 106 | Viewed by 24370
Abstract
An ideal denture base must have good physical and mechanical properties, biocompatibility, and esthetic properties. Various polymeric materials have been used to construct denture bases. Polymethyl methacrylate (PMMA) is the most used biomaterial for dentures fabrication due to its favorable properties, which include [...] Read more.
An ideal denture base must have good physical and mechanical properties, biocompatibility, and esthetic properties. Various polymeric materials have been used to construct denture bases. Polymethyl methacrylate (PMMA) is the most used biomaterial for dentures fabrication due to its favorable properties, which include ease of processing and pigmenting, sufficient mechanical properties, economy, and low toxicity. This article aimed to comprehensively review the current knowledge about denture base materials (DBMs) types, properties, modifications, applications, and construction methods. We searched for articles about denture base materials in PubMed, Scopus, and Embase. Journals covering topics including dental materials, prosthodontics, and restorative dentistry were also combed through. Denture base material variations, types, qualities, applications, and fabrication research published in English were considered. Although PMMA has several benefits and gained popularity as a denture base material, it has certain limitations and cannot be classified as an ideal biomaterial for fabricating dental prostheses. Accordingly, several studies have been performed to enhance the physical and mechanical properties of PMMA by chemical modifications and mechanical reinforcement using fibers, nanofillers, and hybrid materials. This review aimed to update the current knowledge about DBMs’ types, properties, applications, and recent developments. There is a need for specific research to improve their biological properties due to patient and dental staff adverse reactions to possibly harmful substances produced during their manufacturing and use. Full article
(This article belongs to the Section Biobased and Biodegradable Polymers)
Show Figures

Figure 1

15 pages, 8205 KB  
Article
Flexural Properties of Heat-Polymerized PMMA Denture Base Resins Reinforced with Fibers with Different Characteristics
by Kaan Yerliyurt, Taha Buğra Taşdelen, Özlem Eğri and Sinan Eğri
Polymers 2023, 15(15), 3211; https://doi.org/10.3390/polym15153211 - 28 Jul 2023
Cited by 18 | Viewed by 11330
Abstract
Polymethylmethacrylate (PMMA) has been the most-widely used denture base material in prosthetic dentistry for the last 80 years. It is still one of the best alternatives when new methods are inapplicable. Due to the lack of some physical inadequacies occurring during cyclic use [...] Read more.
Polymethylmethacrylate (PMMA) has been the most-widely used denture base material in prosthetic dentistry for the last 80 years. It is still one of the best alternatives when new methods are inapplicable. Due to the lack of some physical inadequacies occurring during cyclic use and accidental situations, various reinforcement strategies such as using nanoparticles, wires, fibers, and meshes have been investigated and reported. In this study, it was aimed to conduct a comparative investigation of the effect of fiber additives with different characteristics on the flexural properties of heat-cured PMMA denture base resins. Glass fibers (GFs), polypropylene fibers (PPFs), and carbon fibers (CFs) having 3, 6, and 12 mm lengths and 0.25, 0.50, and 1.0% concentrations (v/v) were used for the reinforcement of PMMA denture base resins. The flexural properties (flexural strength, flexural modulus, and maximum deformation) were determined using a three-point bending test, and three-way ANOVA analyses with Bonferroni corrections were performed on the test results. The morphologies of the fracture surfaces were analyzed using scanning electron microscopy. All three fibers exhibited reinforcement in the flexural strength (p < 0.001) and flexural modulus (p < 0.001) regardless of their length and concentration. The group with 1.0% 12 mm CF-reinforced PMMA exhibited the greatest flexural strength (94.8 ± 8.8 MPa), and that with 1.0% 3 mm GFs displayed the lowest flexural strength (66.9 ± 10.4 MPa) among the fiber-reinforced groups. The greatest value of the flexural modulus was displayed by the 1.0% 3 mm CF-reinforced resin (3288.3 ± 402.1 MPa). Although the CF-reinforced groups exhibited better flexural properties, CFs are not favorable for use as reinforcement in practice due to the dark gray discoloration of the denture base resin. It was concluded that PPF is a promising material for the reinforcement of heat-cured PMMA denture base resins. Full article
(This article belongs to the Special Issue Additive Manufacturing of Fiber-Reinforced Polymer Composites)
Show Figures

Figure 1

11 pages, 779 KB  
Article
Flexural Behavior of Biocompatible High-Performance Polymer Composites for CAD/CAM Dentistry
by Hanin E. Yeslam
J. Compos. Sci. 2023, 7(7), 270; https://doi.org/10.3390/jcs7070270 - 30 Jun 2023
Cited by 8 | Viewed by 2732
Abstract
High-performance polymeric materials have been used in computer-assisted design/ computer-assisted milling (CAD/CAM) dental restorative treatments due to their favorable esthetics as well as their mechanical and biological properties. Biocompatible poly-ether-ether-ketone (PEEK) and glass-fiber-reinforced composite techno-polymer (FRC) resins reportedly possess good flexural and shock [...] Read more.
High-performance polymeric materials have been used in computer-assisted design/ computer-assisted milling (CAD/CAM) dental restorative treatments due to their favorable esthetics as well as their mechanical and biological properties. Biocompatible poly-ether-ether-ketone (PEEK) and glass-fiber-reinforced composite techno-polymer (FRC) resins reportedly possess good flexural and shock absorption properties. However, intraoral thermal fluctuations may adversely affect them. This study aimed to investigate the flexural strength and effect of thermal aging on two commercially available high-performance polymers intended for CAD/CAM milled frameworks for definitive restorations. A total of 20 bar specimens were prepared using two CAD/CAM materials (n = 10); PEEK(P) and Bioloren FRC(F). Specimens from each material group were randomly divided into two sub-groups (n = 5): before aging (uP and uF) and after aging, with 10,000 thermocycles (5–55 °C) (aP and aF). All specimens were subjected to a three-point bending test in a universal testing machine. Flexural strength (Fs) values were calculated for all specimens, and their means were statistically analyzed using a t-test, and a general linear model (GLM) repeated measure ANOVA (p < 0.05). There was a statistically significant decrease in the Fs of (F) materials after aging (p = 0.03). (F) specimens exhibited significantly higher Fs than (P) before and after aging (p < 0.001). This type of material had a significant effect on Fs (p < 0.001). Within the limitations of this study, both materials exceeded the ISO recommendations of dental resins for flexural strength. However, FRC materials may benefit CAD/CAM milled long-span fixed partial dentures and implant-supported denture frameworks. Full article
(This article belongs to the Special Issue Innovations in Direct and Indirect Dental Composite Restorations)
Show Figures

Figure 1

11 pages, 2583 KB  
Article
Flexural Strength and Vickers Microhardness of Graphene-Doped SnO2 Thin-Film-Coated Polymethylmethacrylate after Thermocycling
by Canan Akay, Gülce Çakmak, Mustafa Borga Donmez, Samir Abou-Ayash, Emre Mumcu, Suat Pat and Burak Yilmaz
Coatings 2023, 13(6), 1106; https://doi.org/10.3390/coatings13061106 - 16 Jun 2023
Cited by 5 | Viewed by 2410
Abstract
Removable dental prostheses are commonly fabricated using polymethylmethacrylate, a material that does not have favorable mechanical properties and needs reinforcement with particles such as graphene. The aim of this study was to evaluate the flexural strength (FS) and Vickers microhardness of a heat-polymerized [...] Read more.
Removable dental prostheses are commonly fabricated using polymethylmethacrylate, a material that does not have favorable mechanical properties and needs reinforcement with particles such as graphene. The aim of this study was to evaluate the flexural strength (FS) and Vickers microhardness of a heat-polymerized polymethylmethacrylate coated with graphene-doped stannic oxide (SnO2) thin films using a thermionic vacuum arc method after thermocycling. Forty bar-shaped specimens (65 × 10 × 3 mm) were fabricated using a heat-polymerized denture base resin and divided into four groups according to the graphene-doped SnO2 thin film surface coating performed: No-coat (uncoated), Coat-15 s (coating duration of 15 s), Coat-20 s (coating duration of 20 s), and Coat-30 s (coating duration of 30 s) (n = 10). The thermionic vacuum arc method was used to coat both surfaces of the specimens of each test group with varying durations, and surface coating was verified using Fourier Transform Infrared Spectroscopy. Specimens were subjected to 10,000 cycles of thermocycling. Atomic force microscopy was used to evaluate the surfaces of all specimens before and after thermocycling. Microhardness values were measured five times and averaged. Then, each specimen was subjected to a three-point bending test, and FS values were calculated. Data were analyzed using one-way analysis of variance and Bonferroni tests (α = 0.05). Differences among test groups were nonsignificant when FS data were considered (p = 0.605). However, significant differences were observed among test groups when Vickers microhardness data were considered (p < 0.001). Coat-30 s had the highest hardness (p ≤ 0.003), while the difference among remaining groups were nonsignificant (p ≥ 0.166). Graphene-doped SnO2 thin film surface coatings did not significantly affect the FS of tested heat-polymerized denture base resin but increased the Vickers microhardness when the coating duration was 30 s. Full article
(This article belongs to the Special Issue Recent Advances in Thin Films Deposited by Vacuum Methods)
Show Figures

Figure 1

Back to TopTop