Sign in to use this feature.

Years

Between: -

Subjects

remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline

Journals

Article Types

Countries / Regions

Search Results (32)

Search Parameters:
Keywords = all-solid-state ion-selective electrode

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
13 pages, 10800 KiB  
Article
On the Stability of the Interface between Li2TiS3 Cathode and Li6PS5Cl Solid State Electrolytes for Battery Applications: A DFT Study
by Riccardo Rocca, Naiara Leticia Marana, Fabrizio Silveri, Maddalena D’Amore, Eleonora Ascrizzi, Mauro Francesco Sgroi, Nello Li Pira and Anna Maria Ferrari
Batteries 2024, 10(10), 351; https://doi.org/10.3390/batteries10100351 - 7 Oct 2024
Viewed by 1844
Abstract
Lithium-titanium-sulfur cathodes have garnered interest due to their distinctive properties and potential applications in lithium-ion batteries. They present various benefits, including lower cost, enhanced safety, and greater energy density compared to the commonly used transition metal oxides. The current trend in lithium-ion batteries [...] Read more.
Lithium-titanium-sulfur cathodes have garnered interest due to their distinctive properties and potential applications in lithium-ion batteries. They present various benefits, including lower cost, enhanced safety, and greater energy density compared to the commonly used transition metal oxides. The current trend in lithium-ion batteries is to move to all-solid-state chemistries in order to improve safety and energy density. Several chemistries for solid electrolytes have been studied, tested, and characterized to evaluate the applicability in energy storage system. Among those, sulfur-based Argyrodites have been coupled with cubic rock-salt type Li2TiS3 electrodes. In this work, Li2TiS3 surfaces were investigated with DFT methods in different conditions, covering the possible configurations that can occur during the cathode usage: pristine, delithiated, and overlithiated. Interfaces were built by coupling selected Li2TiS3 surfaces with the most stable Argyrodite surface, as derived from a previous study, allowing us to understand the (electro)chemical compatibility between these two sulfur-based materials. Full article
(This article belongs to the Special Issue Recent Process of Solid State Lithium Batteries)
Show Figures

Figure 1

16 pages, 2698 KiB  
Article
All-Solid-State Potentiometric Sensor Based on Graphene Oxide as Ion-to-Electron Transducer for Nitrate Detection in Water Samples
by Renato L. Gil, Laura Rodriguez-Lorenzo, Begoña Espiña and Raquel B. Queirós
Chemosensors 2024, 12(6), 86; https://doi.org/10.3390/chemosensors12060086 - 22 May 2024
Cited by 3 | Viewed by 2595
Abstract
Graphene oxide (GO) was used as an ion-to-electron transducer for all-solid-state nitrate electrodes based on an alkyl ammonium salt as the sensing element. Commercially available carbon screen-printed electrodes modified with GO were used as conductive substrates, whose morphology and distribution along the surface [...] Read more.
Graphene oxide (GO) was used as an ion-to-electron transducer for all-solid-state nitrate electrodes based on an alkyl ammonium salt as the sensing element. Commercially available carbon screen-printed electrodes modified with GO were used as conductive substrates, whose morphology and distribution along the surface were evaluated by scanning electron microscopy and Raman spectroscopy. The potentiometric performance of the GO-based electrodes revealed a Nernstian slope of −53.5 ± 2.0 mV decade−1 (R2 = 0.9976 ± 0.0015) in the range from 3.0 × 10−6 to 10−2 M and a lower limit of detection of 1.9 × 10−6 M. An impressive reproducibility between equally prepared electrodes (n = 15) was demonstrated by a variation of <6% for the calibration parameters. Constant current chronopotentiometry and water layer tests were used to evaluate the potential signal stability, providing similar performance to previously published works with graphene-based ion-selective electrodes. Notably, the GO-based sensors showed the absence of a water layer, a long-term drift of 0.3 mV h−1, and a stable performance (LOD and sensitivity) over 3 months. The applicability of the proposed sensors was demonstrated in determining nitrate levels in water samples with great accuracy, yielding recovery values from 87.8 to 107.9%, and comparable (p > 0.05) results to a commercial nitrate probe. These findings demonstrate the use of GO as an alternative ion-to-electron transducer for the fabrication of all-solid-state potentiometric electrodes. Full article
Show Figures

Graphical abstract

17 pages, 4992 KiB  
Article
Potentiometric Phosphate Ion Sensor Based on Electrochemically Modified All-Solid-State Copper Electrode for Phosphate Ions’ Detection in Real Water
by Yang He, Chenhua Han, Hao Du, Ying Ye and Chunhui Tao
Chemosensors 2024, 12(4), 53; https://doi.org/10.3390/chemosensors12040053 - 1 Apr 2024
Cited by 8 | Viewed by 3579
Abstract
The importance of phosphates has sparked researchers’ considerable interest in the electrochemical detection of phosphates within aqueous solutions in recent years. In this study, we present a novel all-solid-state phosphate ion-selective electrode (ISE) that integrates copper, copper nanoparticles, and copper phosphate. By modifying [...] Read more.
The importance of phosphates has sparked researchers’ considerable interest in the electrochemical detection of phosphates within aqueous solutions in recent years. In this study, we present a novel all-solid-state phosphate ion-selective electrode (ISE) that integrates copper, copper nanoparticles, and copper phosphate. By modifying the copper substrate of the electrode with a copper nanoparticle film and creating a lamellar copper phosphate film through electrochemical treatment, we significantly enhanced the electrode’s electron transfer efficiency. This microstructure with large specific surface area markedly improved the electrode’s responsiveness to the targeted ions by accelerating the achievement of chemical equilibrium on the electrode surface, thereby boosting its sensitivity and stability. The newly developed electrode was capable of detecting phosphate ions in solutions with a pH range from 6 to 11 and performed optimally in neutral solutions at pH 7, following Nernst principle, with a detection limit of 1 × 106 M. The electrode exhibited a short response time of less than 10 s with significant reproducibility, stability, longevity—maintaining functionality for more than two months. It also displayed good selectivity as the electrochemical equilibrium was not influenced by up to 1 mM of potential competing species like HCO3, NO3, Cl and SO42. We compared the detection results of current phosphate ion sensor and conventional determination methods for phosphate content in natural lake and aquaculture water samples, with a detection discrepancy of about 10% (RSD). Considering all feasible performance characteristics combined with its low cost, simple manufacture and portability, the sensor provides a new possibility for rapid, reliable, and long-term real-time in situ detection of phosphates. Full article
(This article belongs to the Special Issue Chemical Sensors and Analytical Methods for Environmental Monitoring)
Show Figures

Graphical abstract

3 pages, 1362 KiB  
Abstract
Development of a Potentiometric Nitrate Ion Microsensor Improved Using Conductive Polymer Doped with Carbon Nanotubes as a Transducing Layer
by Camille Bene, Emmanuel Flahaut, Morgan Legnani, Pierre Temple-Boyer and Jérôme Launay
Proceedings 2024, 97(1), 111; https://doi.org/10.3390/proceedings2024097111 - 27 Mar 2024
Cited by 2 | Viewed by 865
Abstract
An all-integrated on-chip electrochemical microcell (10 × 11 mm2) is developed using silicon technology. The potentiometric nitrate ion detection is based on the functionalization of the working microelectrode array with a polymer membrane in fluoropolysiloxane (FPSX) containing ionophore tetradodecylammoniumnitrate (TDDAN) and [...] Read more.
An all-integrated on-chip electrochemical microcell (10 × 11 mm2) is developed using silicon technology. The potentiometric nitrate ion detection is based on the functionalization of the working microelectrode array with a polymer membrane in fluoropolysiloxane (FPSX) containing ionophore tetradodecylammoniumnitrate (TDDAN) and ionic additive potassium tetrakis[3,5-bis(trifuoromethyl)phenyl]borate (KTFPB) to form an all-solid-state ion selective electrode (ISE). The addition of an ion-to-electron transducing layer between the platinum working electrode and the polymer membrane helped to improve the sensor performances, especially the response time, the sensitivity, and the stability. Composites formed with two conductive polymers were compared: Polyethylenedioxythiophène (PEDOT) and Polypyrrole (PPy), doped with Poly(styrene sulfonate) or double-walled carbon nanotubes (DWCNTs). Full article
(This article belongs to the Proceedings of XXXV EUROSENSORS Conference)
Show Figures

Figure 1

13 pages, 2581 KiB  
Article
Integrated Microfluidic Chip Technology for Copper Ion Detection Using an All-Solid-State Ion-Selective Electrode
by Wenpin Zhang, Shuangquan Wang, Dugang Kang, Zhi Xiong, Yong Huang, Lin Ma, Yun Liu, Wei Zhao, Shouliang Chen and Yi Xu
Micromachines 2024, 15(1), 160; https://doi.org/10.3390/mi15010160 - 21 Jan 2024
Cited by 2 | Viewed by 1829
Abstract
This study involved the preparation of an all-solid-state ion-selective electrode (ASS-ISE) with copper and a poly(3,4-ethylenedioxythiophene) and polystyrene sulfonate (PEDOT/PSS) conversion layer through electrode deposition. The morphology of the PEDOT/PSS film was characterized, and the performance of the copper ion-selective film was optimized. [...] Read more.
This study involved the preparation of an all-solid-state ion-selective electrode (ASS-ISE) with copper and a poly(3,4-ethylenedioxythiophene) and polystyrene sulfonate (PEDOT/PSS) conversion layer through electrode deposition. The morphology of the PEDOT/PSS film was characterized, and the performance of the copper ion-selective film was optimized. Additionally, a microfluidic chip for the ASS-ISE with copper was designed and prepared. An integrated microfluidic chip test system with an ASS-ISE was developed using a self-constructed potential detection device. The accuracy of the system was validated through comparison testing with atomic absorption spectrophotometry (AAS). The experimental findings indicate that the relative standard deviation (RSD) of the integrated ASS-ISE with the copper microfluidic chip test system is 4.54%, as compared to the industry standard method. This value complies with the stipulated requirement of an RSD ≤ 5% in DL/T 955-2016. Full article
Show Figures

Figure 1

16 pages, 1899 KiB  
Review
Application of Metal Oxide Nanoparticles in the Field of Potentiometric Sensors: A Review
by Nikola Lenar, Robert Piech, Cecylia Wardak and Beata Paczosa-Bator
Membranes 2023, 13(11), 876; https://doi.org/10.3390/membranes13110876 - 7 Nov 2023
Cited by 12 | Viewed by 3261
Abstract
Recently, there has been rapid development of electrochemical sensors, and there have been numerous reports in the literature that describe new constructions with improved performance parameters. Undoubtedly, this is due to the fact that those sensors are characterized by very good analytical parameters, [...] Read more.
Recently, there has been rapid development of electrochemical sensors, and there have been numerous reports in the literature that describe new constructions with improved performance parameters. Undoubtedly, this is due to the fact that those sensors are characterized by very good analytical parameters, and at the same time, they are cheap and easy to use, which distinguishes them from other analytical tools. One of the trends observed in their development is the search for new functional materials. This review focuses on potentiometric sensors designed with the use of various metal oxides. Metal oxides, because of their remarkable properties including high electrical capacity and mixed ion-electron conductivity, have found applications as both sensing layers (e.g., of screen-printing pH sensors) or solid-contact layers and paste components in solid-contact and paste-ion-selective electrodes. All the mentioned applications of metal oxides are described in the scope of the paper. This paper presents a survey on the use of metal oxides in the field of the potentiometry method as both single-component layers and as a component of hybrid materials. Metal oxides are allowed to obtain potentiometric sensors of all-solid-state construction characterized by remarkable analytical parameters. These new types of sensors exhibit properties that are competitive with those of the commonly used conventional electrodes. Different construction solutions and various metal oxides were compared in the scope of this review based on their analytical parameters. Full article
(This article belongs to the Section Membrane Surfaces and Interfaces)
Show Figures

Figure 1

12 pages, 6972 KiB  
Article
Highly Stretchable and Robust Electrochemical Sensor Based on 3D Graphene Oxide–CNT Composite for Detecting Ammonium in Sweat
by Yunzhi Hua, Mingxiang Guan, Linzhong Xia, Yu Chen, Junhao Mai, Cong Zhao and Changrui Liao
Biosensors 2023, 13(3), 409; https://doi.org/10.3390/bios13030409 - 21 Mar 2023
Cited by 9 | Viewed by 3553
Abstract
Wearable electrochemical sensors have attracted tremendous attention and have been experiencing rapid growth in recent years. Sweat, one of the most suitable biological fluids for non-invasive monitoring, contains various chemical elements relating abundant information about human health conditions. In this work, a new [...] Read more.
Wearable electrochemical sensors have attracted tremendous attention and have been experiencing rapid growth in recent years. Sweat, one of the most suitable biological fluids for non-invasive monitoring, contains various chemical elements relating abundant information about human health conditions. In this work, a new type of non-invasive and highly stretchable potentiometric sweat sensor was developed based on all-solid-state ion-selective electrode (ISE) coupled with poly(dimethylsiloxane; PDMS) and polyurethane (PU). This highly stretchable composite of PDMS-PU allows the sensor to be robust, with the PDMS providing a flexible backbone and the PU enhancing the adhesion between the electrodes and the substrate. In addition, graphene–carbon nanotube (CNT) network 3D nanomaterials were introduced to modify the ion selective membrane (ISM) in order to increase the charge transfer activity of the ISEs, which also could minimize the formation of water layers on the electrode surface, as such nanomaterials are highly hydrophobic. As a result, the sensor demonstrated a wide detection range of NH4+ from 10−6 M to 10−1 M with high stability and sensitivity—showing a high sensitivity of 59.6 ± 1.5 mV/log [NH4+] and an LOD lower than 10−6 M. Under a strain of 40%, the sensor still showed a sensitivity of 42.7 ± 3.1 mV/log [NH4+]. The proposed highly stretchable and robust electrochemical sweat sensor provides a new choice for wearable-device-based personal daily healthcare management beyond hospital-centric healthcare monitoring. Full article
(This article belongs to the Special Issue Advances in Wearable Biosensors for Healthcare Monitoring)
Show Figures

Figure 1

14 pages, 2158 KiB  
Article
Improved Lead Sensing Using a Solid-Contact Ion-Selective Electrode with Polymeric Membrane Modified with Carbon Nanofibers and Ionic Liquid Nanocomposite
by Cecylia Wardak, Klaudia Morawska, Beata Paczosa-Bator and Malgorzata Grabarczyk
Materials 2023, 16(3), 1003; https://doi.org/10.3390/ma16031003 - 21 Jan 2023
Cited by 22 | Viewed by 2901
Abstract
A new solid-contact ion-selective electrode (ISE) sensitive to lead (II) ions, obtained by modifying a polymer membrane with a nanocomposite of carbon nanofibers and an ionic liquid 1-hexyl-3-methylimidazolium hexafluorophosphate, is presented. Electrodes with a different amount of nanocomposite in the membrane (0–9% w/w [...] Read more.
A new solid-contact ion-selective electrode (ISE) sensitive to lead (II) ions, obtained by modifying a polymer membrane with a nanocomposite of carbon nanofibers and an ionic liquid 1-hexyl-3-methylimidazolium hexafluorophosphate, is presented. Electrodes with a different amount of nanocomposite in the membrane (0–9% w/w), in which a platinum wire or a glassy carbon electrode was used as an internal electrode, were tested. Potentiometric and electrochemical impedance spectroscopy measurements were carried out to determine the effect of the ion-sensitive membrane modification on the analytical and electrical parameters of the ion-selective electrode. It was found that the addition of the nanocomposite causes beneficial changes in the properties of the membrane, i.e., a decrease in resistance and an increase in capacitance and hydrophobicity. As a result, the electrodes with the modified membrane were characterized by a lower limit of detection, a wider measuring range and better selectivity compared to the unmodified electrode. Moreover, a significant improvement in the stability and reversibility of the electrode potential was observed, and additionally, they were resistant to changes in the redox potential of the sample. The best parameters were shown by the electrode obtained with the use of a platinum wire as the inner electrode with a membrane containing 6% of the nanocomposite. The electrode exhibited a Nernstian response to lead ions over a wide concentration range, 1.0 × 10−8–1.0 × 10−2 mol L−1, with a slope of 31.5 mV/decade and detection limit of 6.0 × 10−9 mol L−1. In addition, the proposed sensor showed very good long term stability and worked properly 4 months after its preparation without essential changes in the E0 or slope values. It was used to analyze a real sample and correct results of lead content determination were obtained. Full article
(This article belongs to the Special Issue Analysis of Electrode Materials)
Show Figures

Figure 1

16 pages, 6059 KiB  
Article
A Co3O4 Nanoparticle-Modified Screen-Printed Electrode Sensor for the Detection of Nitrate Ions in Aquaponic Systems
by Nguyen Thi Dieu Thuy, Xiaochan Wang, Guo Zhao, Tingyu Liang and Zaihan Zou
Sensors 2022, 22(24), 9730; https://doi.org/10.3390/s22249730 - 12 Dec 2022
Cited by 15 | Viewed by 2757
Abstract
In this study, a screen-printed electrode (SPE) modified with cobalt oxide nanoparticles (Co3O4 NPs) was used to create an all-solid-state ion-selective electrode used as a potentiometric ion sensor for determining nitrate ion (NO3) concentrations in aquaculture water. [...] Read more.
In this study, a screen-printed electrode (SPE) modified with cobalt oxide nanoparticles (Co3O4 NPs) was used to create an all-solid-state ion-selective electrode used as a potentiometric ion sensor for determining nitrate ion (NO3) concentrations in aquaculture water. The effects of the Co3O4 NPs on the characterization parameters of the solid-contact nitrate ion-selective electrodes (SC-NO3-ISEs) were investigated. The morphology, physical properties and analytical performance of the proposed NO3-ion selective membrane (ISM)/Co3O4 NPs/SPEs were studied by X-ray diffraction (XRD), energy-dispersive spectroscopy (EDS), transmission electron microscopy (TEM), scanning electron microscopy (SEM), electrochemical impedance spectroscopy (EIS), cyclic voltammetry (CV), potentiometric measurements, and potentiometric water layer tests. Once all conditions were optimized, it was confirmed that the screen-printed electrochemical sensor had high potential stability, anti-interference performance, good reproducibility, and no water layer formation between the selective membrane and the working electrode. The developed NO3-ISM/Co3O4 NPs/SPE showed a Nernstian slope of −56.78 mV/decade for NO3 detection with a wide range of 10−7–10−2 M and a quick response time of 5.7 s. The sensors were successfully used to measure NO3 concentrations in aquaculture water. Therefore, the electrodes have potential for use in aquaponic nutrient solution applications with precise detection of NO3 in a complicated matrix and can easily be used to monitor other ions in aquaculture water. Full article
(This article belongs to the Section Nanosensors)
Show Figures

Figure 1

17 pages, 3520 KiB  
Article
Geometrical Effect of Active Material on Electrode Tortuosity in All-Solid-State Lithium Battery
by So-Yeon Park, Jiung Jeong and Heon-Cheol Shin
Appl. Sci. 2022, 12(24), 12692; https://doi.org/10.3390/app122412692 - 11 Dec 2022
Cited by 11 | Viewed by 4178
Abstract
In this study, the effect of the active material geometry on the tortuosity in the ion transport path of the electrode composite of an all-solid-state lithium battery was systematically analyzed in terms of the different design and process factors of an electrode. A [...] Read more.
In this study, the effect of the active material geometry on the tortuosity in the ion transport path of the electrode composite of an all-solid-state lithium battery was systematically analyzed in terms of the different design and process factors of an electrode. A direct current technique (i.e., chronoamperometry) using an electron-blocking cell was used to analyze the tortuosity to minimize the experimental error. In addition, aluminum oxide was selected as a hypothetical active material in a composite electrode to exclude the possible disturbance of the ion transport signal caused by real active materials. The experimental results showed that the shape and composition of the active material had significant influences on the ion transport characteristics. In particular, when a fibrous material was applied with a high active material ratio, the degree of tortuosity was significantly increased, reaching values as high as 45, due to the insufficient filling in the micropores formed by particle aggregation. Moreover, the tortuosity degree decreased below 15 as the pressing pressure increased during electrode manufacturing, and the cause of this decrease differed with the active material’s particle shape. The analysis results confirmed that the change in tortuosity resulting from the electrode design factors of an all-solid-state battery has distinctive features compared to that for a conventional liquid electrolyte-based lithium-ion battery. Full article
Show Figures

Figure 1

14 pages, 1521 KiB  
Article
All-Solid State Potentiometric Sensors for Desvenlafaxine Detection Using Biomimetic Imprinted Polymers as Recognition Receptors
by Majed A. Bajaber and Ayman H. Kamel
Polymers 2022, 14(22), 4814; https://doi.org/10.3390/polym14224814 - 9 Nov 2022
Cited by 9 | Viewed by 2179
Abstract
Using single-walled carbon nanotubes (SWCNTs) as an ion-to-electron transducer, a novel disposable all-solid-state desvenlafaxine-selective electrode based on a screen-printed carbon paste electrode was created. SWCNTs were put onto the carbon-paste electrode area, which was protected by a poly (vinyl chloride) (PVC) membrane with [...] Read more.
Using single-walled carbon nanotubes (SWCNTs) as an ion-to-electron transducer, a novel disposable all-solid-state desvenlafaxine-selective electrode based on a screen-printed carbon paste electrode was created. SWCNTs were put onto the carbon-paste electrode area, which was protected by a poly (vinyl chloride) (PVC) membrane with a desvenlafaxine-imprinted polymer serving as a recognition receptor. Electrochemical impedance spectroscopy and chronopotentiometric techniques were used to examine the electrochemical characteristics of the SWCNTs/PVC coating on the carbon screen-printed electrode. The electrode displayed a 57.2 ± 0.8 mV/decade near-Nernstian slope with a 2.0 × 10−6 M detection limit. In 10 mM phosphate buffer, pH 6, the ODV-selective electrodes displayed a quick reaction (5 s) and outstanding stability, repeatability, and reproducibility. The usefulness of electrodes was demonstrated in samples of ODV-containing pharmaceutical products and human urine. These electrodes have the potential to be mass produced and employed as disposable sensors for on-site testing, since they are quick, practical, and inexpensive. Full article
(This article belongs to the Special Issue Conducting Polymers for Advanced Applications Volume II)
Show Figures

Figure 1

20 pages, 2882 KiB  
Review
Unlocking All-Solid Ion Selective Electrodes: Prospects in Crop Detection
by Jiawei Zhai, Bin Luo, Aixue Li, Hongtu Dong, Xiaotong Jin and Xiaodong Wang
Sensors 2022, 22(15), 5541; https://doi.org/10.3390/s22155541 - 25 Jul 2022
Cited by 13 | Viewed by 8187
Abstract
This paper reviews the development of all-solid-state ion-selective electrodes (ASSISEs) for agricultural crop detection. Both nutrient ions and heavy metal ions inside and outside the plant have a significant influence on crop growth. This review begins with the detection principle of ASSISEs. The [...] Read more.
This paper reviews the development of all-solid-state ion-selective electrodes (ASSISEs) for agricultural crop detection. Both nutrient ions and heavy metal ions inside and outside the plant have a significant influence on crop growth. This review begins with the detection principle of ASSISEs. The second section introduces the key characteristics of ASSISE and demonstrates its feasibility in crop detection based on previous research. The third section considers the development of ASSISEs in the detection of corps internally and externally (e.g., crop nutrition, heavy metal pollution, soil salinization, N enrichment, and sensor miniaturization, etc.) and discusses the interference of the test environment. The suggestions and conclusions discussed in this paper may provide the foundation for additional research into ion detection for crops. Full article
(This article belongs to the Collection Advanced Techniques for Acquisition and Sensing)
Show Figures

Figure 1

13 pages, 3284 KiB  
Article
Fabrication of an All-Solid-State Carbonate Ion-Selective Electrode with Carbon Film as Transducer and Its Preliminary Application in Deep-Sea Hydrothermal Field Exploration
by Chuqing Zhang, Yang He, Jianbo Wu, Manqing Ai, Wei Cai, Ying Ye, Chunhui Tao, Pingping Zhang and Quan Jin
Chemosensors 2021, 9(8), 236; https://doi.org/10.3390/chemosensors9080236 - 23 Aug 2021
Cited by 4 | Viewed by 3543
Abstract
Real-time measurements of carbonate ion concentrations in the ocean are critical to advancing marine environmental monitoring and research into deep-sea hydrothermal activity. Herein, we report the first example of deep-sea hydrothermal field exploration using a carbonate ion-selective electrode (ISE). The novel carbonate ISE [...] Read more.
Real-time measurements of carbonate ion concentrations in the ocean are critical to advancing marine environmental monitoring and research into deep-sea hydrothermal activity. Herein, we report the first example of deep-sea hydrothermal field exploration using a carbonate ion-selective electrode (ISE). The novel carbonate ISE was composed of a Ni wire as substrate, carbon film as transducers and carbonate-selective membrane layers. This paper describes the preparation process of the electrode and characterises its performance via scanning electron microscopy (SEM) and electrochemical analysis. The detection limit of the electrode for CO32− is 2.821 × 106 mol/L, the linear response range is 1.0 × 105–1.0 × 101 mol/L and the Nernst slope was −30.4 mV/decade. In April 2021, the carbonate ISE was mounted on multi-parameter sensors with pH and Eh (redox) electrodes for the search of hydrothermal activity at the Southwest Indian Ridge. The simultaneous potential anomalies appeared at this carbonate electrode with the pH and Eh electrodes when passing through the hydrothermal field. The study of the hydrothermal field was supported by the in situ camera video and the sulphide samples. Additionally, the carbonate electrode provides enhanced information of water chemistry for the study of the hydrothermal field. Full article
(This article belongs to the Special Issue Sensors for Water Quality Monitoring)
Show Figures

Figure 1

9 pages, 5353 KiB  
Communication
Using MoS2/Fe3O4 as Ion-Electron Transduction Layer to Manufacture All-Solid-State Ion-Selective Electrode for Determination of Serum Potassium
by Yan Su, Ting Liu, Caiqiao Song, Aiqiao Fan, Nan Zhu, Bingbing Sun and Cheng Yang
Chemosensors 2021, 9(7), 155; https://doi.org/10.3390/chemosensors9070155 - 25 Jun 2021
Cited by 8 | Viewed by 2702
Abstract
As an essential electrolyte for the human body, the potassium ion (K+) plays many physiological roles in living cells, so the rapid and accurate determination of serum K+ is of great significance. In this work, we developed a solid-contact ion-selective [...] Read more.
As an essential electrolyte for the human body, the potassium ion (K+) plays many physiological roles in living cells, so the rapid and accurate determination of serum K+ is of great significance. In this work, we developed a solid-contact ion-selective electrode (SC-ISE) using MoS2/Fe3O4 composites as the ion-to-electron transducer to determine serum K+. The potential response measurement of MoS2/Fe3O4/K+-ISE shows a Nernst response by a slope of 55.2 ± 0.1 mV/decade and a low detection limit of 6.3 × 10−6 M. The proposed electrode exhibits outstanding resistance to the interference of O2, CO2, light, and water layer formation. Remarkably, it also presents a high performance in potential reproducibility and long-term stability. Full article
(This article belongs to the Special Issue Nanotechnology-Based Bio(sensors): In COVID-19 Outbreak)
Show Figures

Figure 1

11 pages, 934 KiB  
Article
Protoporphyrin IX Based All-Solid-State Ion-Selective Electrodes for Choline Determination In Vitro
by You Wang, Siyuan Ma, Hongqun Zou, Zhenyu Wu, Zhiyuan Luo and Guang Li
Appl. Sci. 2021, 11(12), 5549; https://doi.org/10.3390/app11125549 - 15 Jun 2021
Cited by 2 | Viewed by 2439
Abstract
Protoporphyrin IX-based all-solid-state choline (Ch) ion-selective electrodes (ISEs) were fabricated and characterized. Poly (3,4-ethylene dioxythiophene) doped with poly (styrene sulfonate) (PEDOT/PSS) functioning as an ion-to-electron transducer was electropolymerized on the gold wire (0.5 mm diameter). The conductive polymer was covered with a Ch [...] Read more.
Protoporphyrin IX-based all-solid-state choline (Ch) ion-selective electrodes (ISEs) were fabricated and characterized. Poly (3,4-ethylene dioxythiophene) doped with poly (styrene sulfonate) (PEDOT/PSS) functioning as an ion-to-electron transducer was electropolymerized on the gold wire (0.5 mm diameter). The conductive polymer was covered with a Ch selective membrane containing protoporphyrin IX as an ionophore, which exhibited a lower detection limit of 0.49 μM with the potentiometric method. The Ch sensor performed a wide linear range from 1 μM to 1 mM, a fast response time of less than 5 s, and a decent selectivity of common inorganic and organic ions in the human body. Characteristics such as pH and temperature stability, life span, reproducibility and repeatability were also investigated to be satisfied. With the background of artificial cerebrospinal fluid, the recovery rate in 105 M of Ch solution was measured by the standard addition method, revealing the potential for biological application. Full article
(This article belongs to the Special Issue Mechanical and Biomedical Engineering in Paradigm)
Show Figures

Figure 1

Back to TopTop