Sign in to use this feature.

Years

Between: -

Subjects

remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline

Journals

Article Types

Countries / Regions

remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline

Search Results (368)

Search Parameters:
Keywords = Fibre reinforced concrete

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
26 pages, 7199 KiB  
Article
Investigation of Fresh, Mechanical, and Durability Properties of Rubberized Fibre-Reinforced Concrete Containing Macro-Synthetic Fibres and Tyre Waste Rubber
by Nusrat Jahan Mim, Mizan Ahmed, Xihong Zhang, Faiz Shaikh, Ahmed Hamoda, Vipulkumar Ishvarbhai Patel and Aref A. Abadel
Buildings 2025, 15(15), 2778; https://doi.org/10.3390/buildings15152778 - 6 Aug 2025
Abstract
The growing disposal of used tyres and plastic waste in landfills poses a significant environmental challenge. This study investigates the potential of utilizing used tyre rubber and macro-synthetic fibres (MSFs) made from recycled plastics in fibre-reinforced rubberized concrete (RuFRC). Various percentages of tyre [...] Read more.
The growing disposal of used tyres and plastic waste in landfills poses a significant environmental challenge. This study investigates the potential of utilizing used tyre rubber and macro-synthetic fibres (MSFs) made from recycled plastics in fibre-reinforced rubberized concrete (RuFRC). Various percentages of tyre rubber shreds were used to replace coarse aggregates, calculated as 10%, 20%, and 30% of the volume of fine aggregates; fibre dosages (0%, 0.25%, 0.5%, 0.75%, and 1% by volume) were incorporated into the mix, and a series of physical, mechanical, and durability properties were evaluated. The results show that, as the fibre and rubber content increased, the slump of RuFRC decreased, with the lowest value obtained for concrete with 1% fibre and 30% rubber. The density of RuFRC decreases as the rubber percentage increases due to air voids and increased porosity caused by the rubber. The strength properties of RuFRC were found to decline with the increase in the rubber content, with mixes containing 30% rubber exhibiting reductions of about 60% in compressive strength, 27% in tensile strength, and 13% in flexural strength compared to the control specimen. Durability testing revealed that an increased rubber content led to higher water absorption, water penetration, and chloride ion permeability, with 30% rubber showing the highest values. However, lower rubber content (10%) and higher fibre dosages improved the durability characteristics, with water absorption reduced by up to 5% and shrinkage strains lowered by about 7%, indicating better compaction and bonding. These results indicate that RuFRC with moderate rubber and higher fibre content offers a promising balance between sustainability and performance. Full article
(This article belongs to the Section Building Materials, and Repair & Renovation)
Show Figures

Figure 1

26 pages, 23183 KiB  
Article
Fracture Behaviour of Basalt Fibre-Reinforced Lightweight Geopolymer Concrete: A Multidimensional Analysis
by Jutao Tao, Mingxia Jing, Qingshun Yang and Feng Liang
Materials 2025, 18(15), 3549; https://doi.org/10.3390/ma18153549 - 29 Jul 2025
Viewed by 282
Abstract
This study introduced basalt fibres as a reinforcing material and employed notched beam three-point bending tests combined with digital image correlation (DIC) technology to comprehensively evaluate key fracture parameters—namely, initial fracture toughness, unstable fracture toughness, fracture energy, and ductility index—of expanded polystyrene (EPS)-based [...] Read more.
This study introduced basalt fibres as a reinforcing material and employed notched beam three-point bending tests combined with digital image correlation (DIC) technology to comprehensively evaluate key fracture parameters—namely, initial fracture toughness, unstable fracture toughness, fracture energy, and ductility index—of expanded polystyrene (EPS)-based geopolymer concrete with different mix proportions. The results demonstrate that the optimal fracture performance was achieved when the basalt fibre volume content was 0.4% and the EPS content was 20%, resulting in respective increases of 12.07%, 28.73%, 98.92%, and 111.27% in the above parameters. To investigate the toughening mechanisms, scanning electron microscopy was used to observe the fibre–matrix interfacial bonding and crack morphology, while X-ray micro-computed tomography enabled detailed three-dimensional visualisation of internal porosity and crack development, confirming the crack-bridging and energy-dissipating roles of basalt fibres. Furthermore, the crack propagation process was simulated using the extended finite element method, and the evolution of fracture-related parameters was quantitatively analysed using a linear superposition progressive assumption. A simplified predictive model was proposed to estimate fracture toughness and fracture energy based on the initial cracking load, peak load, and compressive strength. The findings provide theoretical support and practical guidance for the engineering application of basalt fibre-reinforced EPS-based geopolymer lightweight concrete. Full article
Show Figures

Figure 1

19 pages, 1058 KiB  
Review
Shear Strength of Lightweight Concrete Structural Elements Reinforced with FRP Bars: Experimental Studies vs. Code Predictions
by Agnieszka Wiater and Tomasz Wojciech Siwowski
Materials 2025, 18(15), 3525; https://doi.org/10.3390/ma18153525 - 27 Jul 2025
Viewed by 369
Abstract
Using lightweight concrete (LWC) reduces the dead weight of the concrete structure by 25–30% compared to ordinary concrete. However, harmful and corrosive substances penetrate the lightweight concrete matrix due to its high permeability, resulting in higher maintenance costs and a reduced structure service [...] Read more.
Using lightweight concrete (LWC) reduces the dead weight of the concrete structure by 25–30% compared to ordinary concrete. However, harmful and corrosive substances penetrate the lightweight concrete matrix due to its high permeability, resulting in higher maintenance costs and a reduced structure service life. Therefore, in harsh environments where conventional steel bars are susceptible to corrosion, fibre-reinforced polymer (FRP) bars should be used for reinforcement. However, there is a paucity of experimental studies regarding LWC structural elements reinforced with FRP bars. Shear strength is a critical limit state that typically determines the proper design of such elements, ensuring the required safety margin and an appropriate level of reliability. The research work was conducted to compare the experimentally determined shear strengths (Vexp) of 50 structural elements (beams, slabs) made of LWC/FRP with code predictions (Vcode) made according to eight codes used for design. Based on this comparison, the so-called conformity coefficient (Vexp/Vcode) was calculated and used to assess which provision documents are the best, considering the entire population of test results. The work demonstrated that the recent Eurocode best predicts the shear strength of LWC/FRP elements. Full article
Show Figures

Figure 1

19 pages, 2652 KiB  
Article
The Effects of Polypropylene Fibres on the Shear Behaviour of a Concrete Crack: An Experimental Study
by Francisco Ortiz-Navas, Juan Navarro-Gregori and Pedro Serna
Fibers 2025, 13(7), 96; https://doi.org/10.3390/fib13070096 - 11 Jul 2025
Viewed by 260
Abstract
The objective of this study is to investigate the effects of macrosynthetic polypropylene fibres as shear reinforcement in a concrete crack. An experimental study was conducted using twenty push-off specimens with varying volumes of fibres, along with plain concrete specimens as a reference. [...] Read more.
The objective of this study is to investigate the effects of macrosynthetic polypropylene fibres as shear reinforcement in a concrete crack. An experimental study was conducted using twenty push-off specimens with varying volumes of fibres, along with plain concrete specimens as a reference. The testing methodology allowed for the analysis of crack kinematics by measuring the evolution of normal and shear stresses in relation to slip and crack opening. This facilitated the creation of diagrams similar to those presented by Walraven (1980) for crack interface shear transfer, but in this case, applied to concrete reinforced with macrosynthetic polypropylene fibres. The findings demonstrate that macrosynthetic polypropylene fibres significantly enhance shear behaviour, particularly when their volume exceeds 8 kg/m3. This study provides valuable insights into the behaviour of macrosynthetic polypropylene fibres under shear loading conditions and highlights their potential benefits as effective shear reinforcement. Full article
(This article belongs to the Special Issue Fracture Behavior of Fiber-Reinforced Building Materials)
Show Figures

Figure 1

29 pages, 4333 KiB  
Article
A Distributed Sensing- and Supervised Deep Learning-Based Novel Approach for Long-Term Structural Health Assessment of Reinforced Concrete Beams
by Minol Jayawickrema, Madhubhashitha Herath, Nandita Hettiarachchi, Harsha Sooriyaarachchi, Sourish Banerjee, Jayantha Epaarachchi and B. Gangadhara Prusty
Metrology 2025, 5(3), 40; https://doi.org/10.3390/metrology5030040 - 3 Jul 2025
Viewed by 263
Abstract
Access to significant amounts of data is typically required to develop structural health monitoring (SHM) systems. In this study, a novel SHM approach was evaluated, with all training data collected solely from a validated finite element analysis (FEA) of a reinforced concrete (RC) [...] Read more.
Access to significant amounts of data is typically required to develop structural health monitoring (SHM) systems. In this study, a novel SHM approach was evaluated, with all training data collected solely from a validated finite element analysis (FEA) of a reinforced concrete (RC) beam and the structural health based on the tension side of a rebar under flexural loading. The developed SHM system was verified by four-point bending experiments on three RC beams cast in the dimensions of 4000 mm × 200 mm × 400 mm. Distributed optical fibre sensors (DOFS) were mounted on the concrete surface and on the bottom rebar to maximise sample points and investigate the reliability of the strain data. The FEA model was validated using a single beam and subsequently used to generate labelled SHM strain data by altering the dilation angle and rebar sizes. The generated strain data were then used to train an artificial neural network (ANN) classifier using deep learning (DL). Training and validation accuracy greater than 98.75% were recorded, and the model was trained to predict the tension state up to 90% of the steel yield limit. The developed model predicts the health condition with the input of strain data acquired from the concrete surface of reinforced concrete beams under various loading regimes. The model predictions were accurate for the experimental DOFS data acquired from the tested beams. Full article
Show Figures

Graphical abstract

35 pages, 10135 KiB  
Article
Constitutive Model for Plain and Steel-Fibre-Reinforced Lightweight Aggregate Concrete Under Direct Tension and Pull-Out
by Hasanain K. Al-Naimi and Ali A. Abbas
Fibers 2025, 13(7), 84; https://doi.org/10.3390/fib13070084 - 23 Jun 2025
Viewed by 436
Abstract
In the present study, a programme of experimental investigations was carried out to examine the direct uniaxial tensile (and pull-out) behaviour of plain and fibre-reinforced lightweight aggregate concrete. The lightweight aggregates were recycled from fly ash waste, also known as Pulverised Fuel Ash [...] Read more.
In the present study, a programme of experimental investigations was carried out to examine the direct uniaxial tensile (and pull-out) behaviour of plain and fibre-reinforced lightweight aggregate concrete. The lightweight aggregates were recycled from fly ash waste, also known as Pulverised Fuel Ash (PFA), which is a by-product of coal-fired electricity power stations. Steel fibres were used with different aspect ratios and hooked ends with single, double and triple bends corresponding to 3D, 4D and 5D types of DRAMIX steel fibres, respectively. Key parameters such as the concrete compressive strength flck, fibre volume fraction Vf, number of bends nb, embedded length LE and inclination angle ϴf were considered. The fibres were added at volume fractions Vf of 1% and 2% to cover the practical range, and a direct tensile test was carried out using a purpose-built pull-out test developed as part of the present study. Thus, the tensile mechanical properties were established, and a generic constitutive tensile stress–crack width σ-ω model for both plain and fibrous lightweight concrete was created and validated against experimental data from the present study and from previous research found in the literature (including RILEM uniaxial tests) involving different types of lightweight aggregates, concrete strengths and steel fibres. It was concluded that the higher the number of bends nb and the higher the volume fraction Vf and concrete strength flck, the stronger the fibre–matrix interfacial bond and thus the more pronounced the enhancement provided by the fibres to the uniaxial tensile residual strength and ductility in the form of work and fracture energy. A fibre optimisation study was also carried out, and design recommendations are provided. Full article
Show Figures

Figure 1

18 pages, 5617 KiB  
Article
Tex-Crete—Carbon and Cost Assessment of Concrete with Textile and Carboard Fibres—Case Studies Towards Circular Economy
by Malindu Sandanayake, Ronja Kraus, Robert Haigh, Ehsan Yaghoubi and Zora Vrcelj
Appl. Sci. 2025, 15(13), 6962; https://doi.org/10.3390/app15136962 - 20 Jun 2025
Viewed by 379
Abstract
Concrete and other cementitious materials are among the most widely used construction materials worldwide. However, their high embodied carbon emissions and energy-intensive manufacturing processes pose significant environmental challenges. This study assesses the carbon emissions, cost implications, and circularity potential of a novel concrete [...] Read more.
Concrete and other cementitious materials are among the most widely used construction materials worldwide. However, their high embodied carbon emissions and energy-intensive manufacturing processes pose significant environmental challenges. This study assesses the carbon emissions, cost implications, and circularity potential of a novel concrete mix, Tex-crete, which incorporates recycled textile and cardboard fibres as sustainable alternatives to conventional reinforcement and cementitious materials in concrete. The study employs a cradle-to-gate life cycle assessment (LCA) approach to compare carbon emissions and costs across different mix designs, using two case studies: a temporary construction site compound and a footpath. Experimental results indicate that Tex-crete, particularly the KFT mix design (including 2.5% textile fibres with treated kraft fibres), achieves comparable compressive and tensile strength to traditional concrete while demonstrating a net reduction in both carbon emissions (3.38%) and production costs (2.56%). A newly introduced circularity index (CI) further evaluated the reuse, repair, and recycling potential of the novel mix, revealing that KFT exhibits the highest circularity score (0.44). Parametric analysis using Monte Carlo simulations highlighted transportation distance and energy consumption during fibre processing as key factors influencing emissions. The findings provide valuable insights for industry stakeholders seeking sustainable concrete solutions aligned with circular economy principles, offering an optimized balance between environmental performance, structural integrity, and cost-effectiveness. Full article
(This article belongs to the Special Issue Advances in Building Materials and Concrete, 2nd Edition)
Show Figures

Figure 1

26 pages, 3697 KiB  
Review
Chloride-Induced Corrosion Effects on the Structural Performance of Concrete with Rebar and Fibres: A Review
by Petar Bajić, Bruno Leporace-Guimil, Carmen Andrade, Nikola Tošić and Albert de la Fuente
Appl. Sci. 2025, 15(12), 6457; https://doi.org/10.3390/app15126457 - 8 Jun 2025
Viewed by 945
Abstract
Chloride-induced corrosion is a major contributor in the degradation of standardised steel-based products (e.g., rebars and fibres) commonly used for reinforcing concrete structures. Since cracked reinforced concrete elements are determined to be more susceptible to corrosion on the one hand, and fibres are [...] Read more.
Chloride-induced corrosion is a major contributor in the degradation of standardised steel-based products (e.g., rebars and fibres) commonly used for reinforcing concrete structures. Since cracked reinforced concrete elements are determined to be more susceptible to corrosion on the one hand, and fibres are effective in arresting crack growth and improving the post-cracking mechanical behaviour on the other hand, the use of fibres emerges as a promising strategy to enhance durability. This review is focused on the degradation of the load-bearing capacity, caused by chloride corrosion, in concrete elements reinforced with fibres and conventional rebar. Based on the recorded values of ultimate loads and the corresponding deflections in the reviewed studies, a lower decrease in the load-bearing capacity and less severe degradation of ductility were observed in elements where fibres (either steel or macro-synthetic) were used in combination with rebar compared with elements where only rebar was used. Furthermore, the recorded values of corrosion potential (Ecorr), corrosion current density (icorr) and gravimetric measurements indicated lower corrosion damage, delayed corrosion initiation and a prolonged propagation phase of corrosion. However, due to many differences in the methodology among the reviewed studies, the optimal fibre type or quantity cannot be identified unless more studies are performed. Full article
(This article belongs to the Special Issue Fiber-Reinforced Concrete: Recent Progress and Future Directions)
Show Figures

Figure 1

27 pages, 4956 KiB  
Review
Recent Advancements in Polypropylene Fibre-Reinforced 3D-Printed Concrete: Insights into Mix Ratios, Testing Procedures, and Material Behaviour
by Ben Hopkins, Wen Si, Mehran Khan and Ciaran McNally
J. Compos. Sci. 2025, 9(6), 292; https://doi.org/10.3390/jcs9060292 - 6 Jun 2025
Viewed by 1071
Abstract
This review presents a comprehensive analysis of polypropylene (PP) fibre incorporation in three-dimensional printed concrete (3DPC), focusing on the material behaviour in both fresh and hardened states. PP fibres play a critical role in improving rheological properties such as buildability, flowability, and extrudability. [...] Read more.
This review presents a comprehensive analysis of polypropylene (PP) fibre incorporation in three-dimensional printed concrete (3DPC), focusing on the material behaviour in both fresh and hardened states. PP fibres play a critical role in improving rheological properties such as buildability, flowability, and extrudability. While increased fibre content enhances interlayer bonding and shape retention through the fibre bridging mechanism, it also raises yield stress and viscosity, which may compromise extrudability. In the hardened state, PP fibres contribute to improvements in compressive and flexural strength up to an optimal dosage, beyond which performance may decline due to fibre clustering and reduced packing density. When aligned with the printing direction, fibres are particularly effective in mitigating shrinkage-induced cracking by redistributing internal tensile stress. However, their inclusion can lead to a slight increase in porosity and promote mechanical anisotropy. This review also discusses mix design parameters, fibre characteristics, and experimental protocols, while identifying key research gaps including the lack of standardized testing methods, limited understanding of fibre orientation effects, and insufficient exploration of hybrid fibre systems. Based on the synthesis of reported studies, optimal print quality and structural consistency have been associated with the use of 6 mm long fibres, nozzle diameters of 4 to 6 mm, and printing speeds ranging from 40 to 60 mm/s. Overall, PP fibre reinforcement shows strong potential for enhancing the structural integrity and dimensional stability of 3D-printed concrete, while emphasizing the need for further studies to optimize its use in practice. Full article
(This article belongs to the Special Issue Feature Papers in Journal of Composites Science in 2025)
Show Figures

Figure 1

17 pages, 1772 KiB  
Article
Selection of a Critical Chloride Level for Full Probabilistic Modelling
by Frank Papworth, Carmen Andrade and Federica Lollini
Corros. Mater. Degrad. 2025, 6(2), 21; https://doi.org/10.3390/cmd6020021 - 31 May 2025
Viewed by 494
Abstract
In 2022, a working party (fib TG 8.9.3) was formed to try and better develop critical chloride (Ccrit) distributions for use in modelling new structures and assessing existing structures. The authors of this paper are leading TG 8.9.3. and are in [...] Read more.
In 2022, a working party (fib TG 8.9.3) was formed to try and better develop critical chloride (Ccrit) distributions for use in modelling new structures and assessing existing structures. The authors of this paper are leading TG 8.9.3. and are in the process of writing a Bulletin (the Bulletin) that will detail how Ccrit values have been developed since the 1970s. The Bulletin notes that chloride-induced corrosion initiation modelling based on Ccrit is not intended as a sole durability assessment tool for structures exposed to chloride. It is recognized that voids and moisture at the bar can control corrosion activation virtually independent of chloride content, but in most cases sufficient voids and moisture are present so that the arrival of adequate chloride triggers corrosion activation of the reinforcement. So, durability verification by modelling restriction of chloride penetration, so that the concentration at the bar is less than that commonly found to cause corrosion, seems appropriate. This empirical approach was first fully detailed in fib Bulletin 34 A key part in the empirical model is the ‘adequate chloride to trigger corrosion activation’ Ccrit. Although Ccrit has a wide distribution and has different distributions in different environments and concrete compositions, its use in modelling provides greater design flexibility and improved confidence compared to the Deemed-to-Satisfy (DtS) rules included in most codes. Because of the limitations in DtS provisions, modelling provides more effective designs by incorporating specific criteria for a broad range of exposures, materials, and construction methods. This paper proposes that a lower bound for Ccrit distributions for a range of materials and exposures can be developed from published papers. This paper includes Ccrit distributions for steel fibres, carbon steel (above and below water), high tensile steel, galvanized steel, and stainless steels. These are expected to be recommended in the Bulletin. Full article
Show Figures

Figure 1

14 pages, 1360 KiB  
Article
Fracture Mechanics-Based Modelling of Post-Installed Adhesive FRP Composite Anchors in Structural Concrete Applications
by Amir Mofidi and Mona Rajabifard
J. Compos. Sci. 2025, 9(6), 282; https://doi.org/10.3390/jcs9060282 - 31 May 2025
Viewed by 450
Abstract
Adhesively bonded fibre-reinforced polymer (FRP) anchors have emerged as a progressive alternative to traditional steel anchors in concrete structures, owing to their superior corrosion resistance, high tensile strength, and light weight. Despite their increasing use, a robust mechanics-based bond model capable of accurately [...] Read more.
Adhesively bonded fibre-reinforced polymer (FRP) anchors have emerged as a progressive alternative to traditional steel anchors in concrete structures, owing to their superior corrosion resistance, high tensile strength, and light weight. Despite their increasing use, a robust mechanics-based bond model capable of accurately predicting the load transfer behaviour has not yet been developed. This study presents a fracture mechanics-based analytical bond model for post-installed adhesive FRP anchors embedded in concrete. The model formulation is derived from fundamental equilibrium and compatibility principles, incorporating a bilinear bond–slip law that captures both elastic and softening behaviours. A new expression for the effective bond length is also proposed. Validation of the model against a comprehensive database of direct pull-out tests reported in the literature shows excellent agreement between predicted and experimental pull-out forces (R2 = 0.980; CoV = 0.058). Future research should aim to extend the proposed model to account for confinement effects, long-term durability, the impact of adhesive type, and cyclic loading conditions. Full article
Show Figures

Figure 1

25 pages, 5455 KiB  
Article
Experimental Study on Frost Durability of Sprayed Glass Fibre Epoxy Mortar (GFEM)-Reinforced Concrete Specimens
by Jianhui Si, Yuanhao Li, Wenshuo Sun, Xiaoyu Niu, Junpeng Ju, Lizhe He and Junlin Xiang
Buildings 2025, 15(11), 1896; https://doi.org/10.3390/buildings15111896 - 30 May 2025
Viewed by 277
Abstract
Addressing the shortcomings of currently available concrete reinforcement techniques, a new method using sprayed Glass Fibre Epoxy Mortar (GFEM) reinforcement is proposed. To investigate the effect of this method on the frost durability of concrete, a total of 156 specimens in four groups [...] Read more.
Addressing the shortcomings of currently available concrete reinforcement techniques, a new method using sprayed Glass Fibre Epoxy Mortar (GFEM) reinforcement is proposed. To investigate the effect of this method on the frost durability of concrete, a total of 156 specimens in four groups were designed, and related freezing and thawing cycle tests were conducted. The apparent morphology, mass loss rate, ultrasonic velocity, freeze–thaw damage, and strength loss rate of each group of specimens after different freeze–thaw cycles were analysed comparatively. The test results show that the concrete specimens reinforced with GFEM have a better mass loss rate after freeze–thaw cycles and ultrasonic wave velocity than the unreinforced concrete specimens. The compressive strength of specimens in group A is 24.04 MPa, and the compressive strengths of specimens in groups B, C, and D are 35.28 MPa, 35.73 MPa, and 36.37 MPa, respectively, which is higher than that of group A by 46.76%, 48.63%, and 51.29%, respectively, and 46.76%, 48.63%, and 51.29% higher than group A, respectively. It can be seen that the concrete specimens reinforced with sprayed Glass Fibre Epoxy Mortar can effectively improve the frost durability of concrete; the reinforcing effect is obvious, and in a certain range of fibre mixing, the larger the better the frost resistance. The integration of GFEM is cost-effective and improves viscosity, and the best glass fibre mix percentage is about 0.8%. A freeze–thaw damage model for GFEM-reinforced concrete was developed using the Weibull distribution theory, and an improved strength attenuation model under freeze–thaw cycles was established. By correlating the strength attenuation model with the freeze–thaw damage model, a damage evolution equation for the reinforced specimens was formulated, allowing for the prediction of freeze–thaw damage based on the number of cycles and the relative compressive strength. Full article
(This article belongs to the Section Building Structures)
Show Figures

Figure 1

20 pages, 1633 KiB  
Article
Rheological and Mechanical Properties of Self-Compacting Geopolymer Concrete Reinforced with Short Basalt Fibres
by Saima Ali, Pulkit Khanna, James Stewart, Bidur Kafle and Riyadh Al-Ameri
J. Compos. Sci. 2025, 9(6), 264; https://doi.org/10.3390/jcs9060264 - 26 May 2025
Viewed by 395
Abstract
Due to their low environmental impact, various mineral or cellulose-based natural fibres have recently attracted attention in the construction industry. Hence, the current study focused on basalt fibres and explored the changes in the physical, mechanical, and micro-structural properties of geopolymer concrete reinforced [...] Read more.
Due to their low environmental impact, various mineral or cellulose-based natural fibres have recently attracted attention in the construction industry. Hence, the current study focused on basalt fibres and explored the changes in the physical, mechanical, and micro-structural properties of geopolymer concrete reinforced with such fibres. The current study used self-compacting geopolymer concrete, an eco-friendly concrete composed of fly ash, ground granulated blast furnace slag, and an alkali activator, in addition to the regular components of normal concrete. The self-compacting geopolymer concrete compacts under its own weight, so extra compaction is not required. The present study investigated the effect of the fibre content and length. Two different fibre lengths were considered: 12 mm and 30 mm. Three different percentages (1%, 2%, and 3% of the weight of the total mix) of the basalt fibres were considered to determine the optimum fibre content. The mix design was carried out for all the mixes with different fibre contents and fibre lengths, and the workability properties in the slump flow, T-500, and J-ring tests are presented. The effects of the fibre length and content were evaluated in terms of compressive strength (28 and 56 days) and split tensile strength. The results indicated that a higher fibre content effectively increased the compressive strength of 12 mm long fibres. In contrast, a lower fibre content was ideal for the 30 mm long fibres. In addition, the short fibres were more effective in enhancing the geopolymer concrete’s tensile strength than the long fibres. Furthermore, a detailed microscopic analysis was carried out, which revealed that fibre clustering, voids, etc., changed the strength of the selected fibre-reinforced self-compacting geopolymer concrete. Moreover, the analytical method’s predicted tensile strength agreed with the experimental results. Full article
(This article belongs to the Special Issue Mechanical Properties of Composite Materials and Joints)
Show Figures

Figure 1

27 pages, 2122 KiB  
Article
Research on the Possibilities of Using Sulfur Concrete for Road Infrastructure Construction—Assessment Based on European Standards
by Beata Łaźniewska-Piekarczyk
Sustainability 2025, 17(8), 3671; https://doi.org/10.3390/su17083671 - 18 Apr 2025
Viewed by 688
Abstract
Sulphur is generated in large quantities as an industrial byproduct, and one promising method of its reuse is in sulphur concrete as an alternative binder to Portland cement. In this study, a sulphur polymer (waste sulphur) modified with 5% styrene was evaluated as [...] Read more.
Sulphur is generated in large quantities as an industrial byproduct, and one promising method of its reuse is in sulphur concrete as an alternative binder to Portland cement. In this study, a sulphur polymer (waste sulphur) modified with 5% styrene was evaluated as a binder in concrete for road infrastructure. The sulphur concrete was tested for its compressive strength, abrasion resistance, water absorption, freeze–thaw durability, water impermeability, and leachate chemistry, in relation to relevant European standards for transport concretes. The modified sulphur concrete achieved high early strength (compressive strength class C40/45) and exhibited very low water absorption and high resistance to abrasion and water penetration. However, it did not satisfy frost resistance requirements: after 150 freeze–thaw cycles, its compressive strength dropped by over 30% (well beyond the 20% acceptable loss), meaning that the material only achieved an F50 rating instead of the F150 rating that is required. In addition, the material is inherently flammable, which poses safety limitations. Unmodified (styrene-modified only) sulphur concrete cannot yet replace conventional concrete in structural applications where it would be exposed to significant freeze–thaw cycling or high fire risk. It may be suitable for less demanding uses, for example in chemically aggressive environments or for precast elements that are not subject to freezing. Further research should explore modifications (such as fibre reinforcement or additional polymer additives) to improve the frost resistance and overall durability of sulphur concrete for broader infrastructure applications. Full article
Show Figures

Figure 1

16 pages, 1481 KiB  
Article
Cost-Effectiveness of Reinforced Recycled Aggregate Concrete Structures with Fly Ash and Basalt Fibres Under Corrosion: A Life Cycle Cost Analysis
by Abdelrahman Abushanab and Vanissorn Vimonsatit
Buildings 2025, 15(7), 1167; https://doi.org/10.3390/buildings15071167 - 2 Apr 2025
Viewed by 884
Abstract
Recent investigations have shown that the mechanical and durability properties of recycled aggregate concrete can be enhanced using fly ash (FA) and structural fibres. However, the financial viability of combining these products in concrete has not yet been evaluated. Therefore, this study assessed [...] Read more.
Recent investigations have shown that the mechanical and durability properties of recycled aggregate concrete can be enhanced using fly ash (FA) and structural fibres. However, the financial viability of combining these products in concrete has not yet been evaluated. Therefore, this study assessed the long-term cost-effectiveness of using recycled concrete aggregates (RCA), FA, and basalt fibres (BF) simultaneously in high-rise reinforced concrete buildings exposed to corrosive environments. A life cycle cost analysis was conducted using five variables, two design alternatives, and twelve design scenarios. The analysis followed ISO 15686–5:2017 using a discount rate of 0.5% and a construction-to-material cost ratio of 150%. The components considered in the life cycle cost model included materials, construction, maintenance, and disposal. The results demonstrated that employing RCA, FA, and BF in combination in concrete buildings located near the ocean achieved approximately 21% cost savings compared to buildings made with conventional materials over a lifespan of 50 years. The maintenance component exhibited the most significant cost savings, with an average reduction of about 76% in the maintenance costs for all buildings utilising RCA, FA, and BF. The sensitivity analysis revealed that the proposed building with RCA, FA, and BF remained more cost-effective than the conventional concrete building, even with an increasing RCA-to-natural-aggregate price ratio, construction-to-material cost ratio, and increasing the discount rate to 200%, 250%, and 10%, respectively. Full article
Show Figures

Figure 1

Back to TopTop