Analysis and Optimization of Operating Parameters for PEMFC Stack Performance and Vehicle Hydrogen Consumption in Heavy-Duty Trucks
by Fusong Long, Yushan Cao, Junyan Ren and Zheshu Ma
Processes 2026, 14(15), 2446; https://doi.org/10.3390/pr14152446 - 29 Jul 2026
Viewed by 191
Abstract
This study investigates the performance and hydrogen consumption of a 120 kW PEM fuel cell stack in a SANY heavy-duty truck under high-load operating conditions. A stack model was developed based on first-generation Toyota Mirai single-cell data and verified for applicability to the [...] Read more.
This study investigates the performance and hydrogen consumption of a 120 kW PEM fuel cell stack in a SANY heavy-duty truck under high-load operating conditions. A stack model was developed based on first-generation Toyota Mirai single-cell data and verified for applicability to the target vehicle. The effects of operating parameters—including temperature, hydrogen and air partial pressures, and membrane water activity—on stack ECOP, power, efficiency, and vehicle hydrogen consumption under the C-WTVC driving cycle were analyzed. Multi-objective optimization using NSGA-II identified parameter combinations that improved overall stack performance. Results show that key operational parameters significantly influence both stack and vehicle-level performance. After optimization, the stack exhibited enhanced power and efficiency, and the truck’s equivalent hydrogen consumption decreased to 2.227 kg, which is lower than both the unoptimized and reference conditions. Full article
(This article belongs to the Section Chemical Processes and Systems)
Show Figures

Figure 1

21 pages, 4251 KB  
Article
Comparative Analysis of Unsteady Natural Convection and Thermal Performance in Rectangular and Square Cavities Filled with Stratified Air
by Syed Mehedi Hassan Shaon, Md. Mahafujur Rahaman, Suvash C. Saha and Sidhartha Bhowmick
Fluids 2026, 11(2), 33; https://doi.org/10.3390/fluids11020033 - 27 Jan 2026
Cited by 1 | Viewed by 1003
Abstract
A comprehensive numerical analysis has been conducted to investigate unsteady natural convection (UNC), bifurcation behavior, and heat transfer (HT) in a rectangular enclosure containing thermally stratified air. The enclosure comprises a uniformly heated bottom wall, thermally stratified vertical sidewalls, and a cooled top [...] Read more.
A comprehensive numerical analysis has been conducted to investigate unsteady natural convection (UNC), bifurcation behavior, and heat transfer (HT) in a rectangular enclosure containing thermally stratified air. The enclosure comprises a uniformly heated bottom wall, thermally stratified vertical sidewalls, and a cooled top wall. To assess thermal performance, square and rectangular cavities with identical boundary conditions and working fluid are considered. The finite volume method (FVM) is used to solve the governing equations over a wide range of Rayleigh numbers (Ra = 101 to 109) for air with a Prandtl number (Pr) of 0.71. Flow dynamics and thermal performance are analyzed using temperature time series (TTS), limit point–limit cycle behavior, average Nusselt number (Nuavg), average entropy generation (Savg), average Bejan number (Beavg), and the ecological coefficient of performance (ECOP). In the rectangular cavity, the transition from steady to chaotic flow exhibits three bifurcations: a pitchfork bifurcation at Ra = 3 × 104–4 × 104, a Hopf bifurcation at Ra = 3 × 106–4 × 106, and the onset of chaotic flow at Ra = 9 × 107–2 × 108. The comparative analysis indicates that Nuavg remains nearly identical for both cavities within Ra = 105 to 107. However, at Ra = 108, the HT rate in the rectangular cavity is 29.84% higher than that of the square cavity, while Savg and Beavg differ by 39.32% and 37.50%, respectively. Despite higher HT and Savg in the rectangular enclosure, the square cavity demonstrates superior overall thermal performance by 13.52% at Ra = 108. These results offer significant insights for optimizing cavity geometries in thermal system design based on energy efficiency and entropy considerations. Full article
(This article belongs to the Special Issue Convective Flows and Heat Transfer)
Show Figures

Figure 1

24 pages, 9410 KB  
Article
Performance Analysis and Optimization of Fuel Cell Vehicle Stack Based on Second-Generation Mirai Vehicle Data
by Liangyu Tao, Yan Zhu, Hongchun Zhao and Zheshu Ma
Sustainability 2026, 18(3), 1172; https://doi.org/10.3390/su18031172 - 23 Jan 2026
Viewed by 1011
Abstract
To accurately investigate the loss characteristics of fuel cell vehicles (FCVs) under actual operating conditions and enhance their power performance and economic efficiency, this study establishes a numerical model of the proton exchange membrane fuel cell (PEMFC) stack based on real-world data from [...] Read more.
To accurately investigate the loss characteristics of fuel cell vehicles (FCVs) under actual operating conditions and enhance their power performance and economic efficiency, this study establishes a numerical model of the proton exchange membrane fuel cell (PEMFC) stack based on real-world data from the second-generation Mirai. The stack model incorporates leakage current losses and imposes a limit on maximum current density. Besides, this study analyzes the effects of operating parameters (PEM water content, hydrogen partial pressure, current density, oxygen partial pressure, and operating temperature) on stack power output, efficiency, and eco-performance coefficient (ECOP). Furthermore, Non-Dominated Sequential Genetic Algorithm (NSGA-II) is employed to optimize the PEMFC stack performance, yielding the optimal operating parameter set for FCV operation. Further simulations are conducted on dynamic performance characteristics of the second-generation Mirai under two typical driving cycles, evaluating the power performance and economy of the FCV before and after optimization. Results demonstrate that the established PEMFC stack model accurately analyzes the output performance of an actual FCV when compared with real-world performance test data from the second-generation Mirai. Through optimization, output power increases by 7.4%, efficiency improves by 1.95%, and ECOP rises by 3.84%, providing guidance for enhancing vehicle power performance and improving overall vehicle economy. This study provides a practical framework for enhancing the power performance and overall energy sustainability of fuel cell vehicles, contributing to the advancement of sustainable transportation. Full article
(This article belongs to the Section Sustainable Engineering and Science)
Show Figures

Figure 1

22 pages, 4044 KB  
Article
Thermodynamic Evaluation of Novel Ejector-Integrated Compression–Absorption Cascade Refrigeration System
by Yuhan Du, Wenzhe Dang and Xiaopo Wang
Energies 2025, 18(24), 6544; https://doi.org/10.3390/en18246544 - 14 Dec 2025
Viewed by 660
Abstract
The compression–absorption cascade refrigeration cycle (CACRC) has attracted considerable interest due to its advantages of decreasing electricity consumption and enhancing efficiency of energy utilization. To further reduce irreversibility and improve energy efficiency, the ejector was integrated into an absorption refrigeration subsystem (EA1, EA2) [...] Read more.
The compression–absorption cascade refrigeration cycle (CACRC) has attracted considerable interest due to its advantages of decreasing electricity consumption and enhancing efficiency of energy utilization. To further reduce irreversibility and improve energy efficiency, the ejector was integrated into an absorption refrigeration subsystem (EA1, EA2) and a vapor-compression refrigeration subsystem (EC1, EC2, EC3) in the CACRC, respectively. Six novel ejector-based CACRC systems (EA1-EC1, EA1-EC2, EA1-EC3, EA2-EC1, EA2-EC2, and EA2-EC3 cascade systems) were developed in this work. A comparative analysis was performed to evaluate the performance of the proposed systems and conventional CACRC using NH3/H2O and R41 as working fluids. The effects of the evaporator temperature, generator temperature, condenser temperature, absorber temperature, and the temperature difference across the cascade heat exchanger on COP, ECOP, input power, and total exergy destruction of the system were analyzed. Results show that the proposed ejector-based CACRC systems have better performance than that of the conventional CACRC. The EA1-EC1 cascade system has the superior performance, and the improvements of COP and ECOP are about 7.96% and 10.86% compared to the conventional CACRC. The analysis of exergy destruction for each component in the proposed system shows that the main exergy destruction occurs in the generator, compressor, and absorber. Full article
(This article belongs to the Section G: Energy and Buildings)
Show Figures

Figure 1

36 pages, 25371 KB  
Article
Performance Evaluation of Various Nanofluids in MHD Natural Convection Within a Wavy Trapezoidal Cavity Containing Heated Square Obstacles
by Sree Pradip Kumer Sarker and Md. Mahmud Alam
Math. Comput. Appl. 2025, 30(6), 126; https://doi.org/10.3390/mca30060126 - 18 Nov 2025
Viewed by 1353
Abstract
Natural convection enhanced by magnetic fields and nanofluids has broad applications in thermal management systems. This study investigates magnetohydrodynamic (MHD) natural convection in a wavy trapezoidal cavity containing centrally located heated square obstacles, filled with various nanofluids Cu–H2O, Fe3O [...] Read more.
Natural convection enhanced by magnetic fields and nanofluids has broad applications in thermal management systems. This study investigates magnetohydrodynamic (MHD) natural convection in a wavy trapezoidal cavity containing centrally located heated square obstacles, filled with various nanofluids Cu–H2O, Fe3O4–H2O, and Al2O3–H2O. A uniform magnetic field is applied horizontally, and the effects of key parameters such as Rayleigh number, Ra (103–106), Hartmann number, Ha (0–50), and nanoparticle volume fraction, φ (0.00, 0.02, 0.04) are analyzed. The numerical simulations are performed using the finite element method, incorporating a wavy upper boundary and slanted sidewalls to model realistic enclosures. Results show that an increasing Rayleigh number enhances heat transfer, while a stronger magnetic field reduces convective flow. Among the nanofluids, Cu–H2O demonstrates the highest Nusselt number and ecological coefficient of performance (ECOP), whereas Fe3O4–H2O exhibits superior performance under stronger magnetic fields due to its magnetic nature. Entropy generation, ST decreases with increasing Ra and φ, indicating reduced thermodynamic irreversibility. These results provide insights into designing energy-efficient enclosures using nanofluids under magnetic control. Full article
Show Figures

Figure 1

25 pages, 37763 KB  
Article
Scenario Simulation and Spatial Management Implications of Water Ecosystem Services in the Guangdong-Hong Kong-Macao Greater Bay Area (2035)
by Yixuan Han and Yiling Chen
Water 2025, 17(19), 2838; https://doi.org/10.3390/w17192838 - 28 Sep 2025
Cited by 1 | Viewed by 1099
Abstract
Rapid urbanization threatens water ecosystem services (WESs) in China’s Greater Bay Area. This study employs a Markov-FLUS land-use simulation coupled with the InVEST model to project land-use patterns for 2035 under four scenarios—Natural Development (ND), Farmland Protection (FP), Economic Priority (EP), and Ecological [...] Read more.
Rapid urbanization threatens water ecosystem services (WESs) in China’s Greater Bay Area. This study employs a Markov-FLUS land-use simulation coupled with the InVEST model to project land-use patterns for 2035 under four scenarios—Natural Development (ND), Farmland Protection (FP), Economic Priority (EP), and Ecological Protection (EcoP)—and evaluates their impacts on water yield, soil retention, and total phosphorus (TP) export. Under ND and FP scenarios, modest gains in water yield (+32.25% and +32.13%) and soil retention (+46.16% and +45.91%) are achieved, but TP control remains limited (−0.05% and +4.82%). In contrast, the EP scenario drives severe declines in water yield (−13.39%) and soil retention (−2.11%) alongside a TP surge (+5.87%), evidencing ecological degradation under high-intensity development. Conversely, the EcoP scenario yields substantial improvements, water yield +50.67%, soil retention +70.94%, and TP export −8.17%, reflecting the synergistic “multiplier effect” of combined woodland and water-body restoration. Spatially, urban cores and agricultural margins exhibit divergent service responses, underscoring the need for differentiated management. We developed a spatial priority map by integrating the predicted WES changes under the Ecological Protection scenario with indicators of urban proximity and pollution risk. This map identifies critical intervention zones. We propose targeted spatial optimization—strict protection of sensitive ecological zones, green transformation in urban expansion areas, and diffuse pollution controls in agricultural peripheries—to reconcile development with ecosystem resilience. Full article
(This article belongs to the Special Issue Monitoring and Modelling of Contaminants in Water Environment)
Show Figures

Figure 1

18 pages, 2519 KB  
Article
Unsteady Natural Convection and Entropy Generation in Thermally Stratified Trapezoidal Cavities: A Comparative Study
by Md. Mahafujur Rahaman, Sidhartha Bhowmick and Suvash C. Saha
Processes 2025, 13(6), 1908; https://doi.org/10.3390/pr13061908 - 16 Jun 2025
Cited by 4 | Viewed by 1305
Abstract
This study numerically investigates unsteady natural convection (NC) heat transfer (HT) and entropy generation (Egen) in trapezoidal cavities filled with two thermally stratified fluids. Both air-filled and water-filled configurations are analyzed to evaluate and compare their thermal performance under varying [...] Read more.
This study numerically investigates unsteady natural convection (NC) heat transfer (HT) and entropy generation (Egen) in trapezoidal cavities filled with two thermally stratified fluids. Both air-filled and water-filled configurations are analyzed to evaluate and compare their thermal performance under varying conditions. The cavities are characterized by a heated base, thermally stratified sloped walls, and a cooled top wall. The governing equations are numerically solved using the finite volume (FV) approach. The study considers a Prandtl number (Pr) of 0.71 for air and 7.01 for water, Rayleigh numbers (Ra) ranging from 103 to 5 × 107, and an aspect ratio (AR) of 0.5. Flow behavior is examined through various parameters, including temperature time series (TTS), average Nusselt number (Nu), average entropy generation (Eavg), average Bejan number (Beavg), and ecological coefficient of performance (ECOP). Three bifurcations are identified during the transition from steady to chaotic flow for both fluids. The first is a pitchfork bifurcation, occurring between Ra = 105 and 2 × 105 for air, and between Ra = 9 × 104 and 105 for water. The second, a Hopf bifurcation, is observed between Ra = 4.7 × 105 and 4.8 × 105 for air, and between Ra = 105 and 2 × 105 for water. The third bifurcation marks the onset of chaotic flow, occurring between Ra = 3 × 107 and 4 × 107 for air, and between Ra = 4 × 105 and 5 × 105 for water. At Ra = 106, the average HT in the air-filled cavity is 85.35% higher than in the water-filled cavity, while Eavg is 94.54% greater in the air-filled cavity compared to water-filled cavity. At Ra = 106, the thermal performance of the cavity filled with water is 4.96% better than that of the air-filled cavity. These findings provide valuable insights for optimizing thermal systems using trapezoidal cavities and varying working fluids. Full article
Show Figures

Figure 1

25 pages, 8275 KB  
Article
Numerical Analysis of Magnetohydrodynamic Convection in an Inclined Cavity with Three Fins and a Ternary Composition of Nanoparticles
by Huda Alfannakh
Processes 2024, 12(12), 2889; https://doi.org/10.3390/pr12122889 - 17 Dec 2024
Cited by 2 | Viewed by 1675
Abstract
The natural convection heat transfer of a trihybrid nanofluid comprising Fe2O3, MoS2, and CuO nanoparticles dispersed in water (Fe2O3 + MoS2 + CuO/H2O) has been investigated within a cavity exposed to [...] Read more.
The natural convection heat transfer of a trihybrid nanofluid comprising Fe2O3, MoS2, and CuO nanoparticles dispersed in water (Fe2O3 + MoS2 + CuO/H2O) has been investigated within a cavity exposed to a uniform magnetic field. Three cold fins were strategically positioned on the top, right, and left walls of the enclosure. The study employs numerical simulations conducted using a custom-developed FORTRAN code. The computational approach integrates the finite volume method and full multigrid acceleration to solve the coupled governing equations for continuity, momentum, energy, and entropy generation, along with the associated boundary conditions. Prior to obtaining the results, a meticulous parameterization process was undertaken to accurately capture the fluid dynamics and thermal behavior characteristic of this geometric configuration. The findings underscored the key parameters’ significant impact on the flow structure and thermal performance. The results revealed that natural convection is more dominant at high Rayleigh and low Hartmann numbers, leading to higher Nusselt numbers and stronger dependence on the tilt angle α. Moreover, the optimal heat transfer conditions were obtained for the following parameters: Ha = 25, α = 45°, ϕ = 6%, and Ra = 106 with a rate of 4.985. This study offers valuable insights into achieving a balance between these competing factors by determining the optimal conditions for maximizing heat transfer while minimizing entropy generation. The findings contribute to enhancing the design of thermal systems that utilize magnetic nanofluids for efficient heat dissipation, making the research particularly relevant to advanced cooling technologies and compact thermal management solutions. Full article
(This article belongs to the Special Issue Flow, Heat and Mass Transfer in Energy Utilization)
Show Figures

Figure 1

13 pages, 7652 KB  
Article
A Hardware Encoder-Based Synchronization Method for a Fast Terahertz TDS Imaging System Based on the ECOPS Scheme
by Marcin Maciejewski, Kamil Kamiński and Norbert Pałka
Sensors 2024, 24(6), 1806; https://doi.org/10.3390/s24061806 - 11 Mar 2024
Cited by 2 | Viewed by 2127
Abstract
In this paper, we report our use of a hardware encoder-based synchronization method for a fast terahertz time-domain spectroscopy raster scanner built with the commercially available TeraFlash Smart platform. We describe the principles of our method, including our incorporation of synchronization signals from [...] Read more.
In this paper, we report our use of a hardware encoder-based synchronization method for a fast terahertz time-domain spectroscopy raster scanner built with the commercially available TeraFlash Smart platform. We describe the principles of our method, including our incorporation of synchronization signals from various devices included in the scanner. We also describe its implementation in a microcontroller with a dedicated counter. By such means, a fast scanning mode was obtained, which was 35 times faster than a traditional step-by-step approach. To validate the proposed synchronization method, we carried out measurements using the USAF 1951 resolution test and a fiberglass plate with a set of intentionally introduced defects. Our results confirmed that the TDS scanner with the developed synchronization method was able to capture high-quality images with resolutions as high as those obtained using traditional step-by-step scanning, but with significantly reduced scanning times. Full article
Show Figures

Figure 1

19 pages, 3618 KB  
Article
Validation of the Scale on Parental Feeding Behaviors (ECOPAL) for Caregivers of Mexican Children
by Marina Liliana González-Torres, Xochitl Garza-Olivares, Gabriela Navarro-Contreras and Lidia Alejandra González-Orozco
Nutrients 2023, 15(17), 3698; https://doi.org/10.3390/nu15173698 - 24 Aug 2023
Cited by 2 | Viewed by 2468
Abstract
Parental feeding practices can be crucial to preventing childhood obesity. This study aimed to validate a self-applicable instrument for evaluating the diverse parental feeding behaviors of Mexican caregivers based on the theoretical constructs of coercive control, structure, and autonomy support. The scale’s content [...] Read more.
Parental feeding practices can be crucial to preventing childhood obesity. This study aimed to validate a self-applicable instrument for evaluating the diverse parental feeding behaviors of Mexican caregivers based on the theoretical constructs of coercive control, structure, and autonomy support. The scale’s content validity achieved significant values when assessed by expert judges, with moderate intensity in congruence (Kendall’s W = 0.462; p = 0.000) and clarity (Kendall’s W = 0.369; p = 0.001). The participants were 1185 Mexican adults (32.7 ± 7.6 years of age, 97% women, and 90% mothers) responsible for the main meal of at least one child (4.8 ± 3 years old). The data were subdivided randomly for an exploratory factor analysis (n = 581) and a confirmatory factorial analysis (n = 604). The first analysis grouped the items into 11 factors, with an accumulated variance of 63.9%. In the confirmatory analysis, a 10-factor model showed a better fit (CMIN = 1531.5, p < 0.001, CMIN/df = 2.20, RSEA = 0.045, CFI = 0.92, TLI, 0.91, and NFI = 0.87). The factors in this model were (1) the disposition of non-recommended foods, (2) nutritional education, (3) pressure to eat, (4) praise for healthy eating, (5) monitoring of consumption, (6) structured offer of fruits and vegetables, (7) consumption conditioning, (8) overt restriction, (9) guided choices, and (10) covert restriction. The Cronbach’s alpha value was 0.816. Therefore, this scale presents good psychometric properties with which to evaluate the frequency of child caregivers’ feeding behaviors in the context of ten different feeding practices in Mexico’s urban areas and contributes to the knowledge of current practices in the Mexican population. It also evaluates changes resulting from future interventions that promote eating practices that favor the formation of healthy eating habits. Full article
(This article belongs to the Special Issue Advances in Infant and Pediatric Feeding and Nutrition)
Show Figures

Figure 1

12 pages, 9507 KB  
Article
Fast THz-TDS Reflection Imaging with ECOPS—Point-by-Point versus Line-by-Line Scanning
by Norbert Pałka, Marcin Maciejewski, Kamil Kamiński, Marek Piszczek, Przemysław Zagrajek, Elżbieta Czerwińska, Michał Walczakowski, Krzysztof Dragan, Piotr Synaszko and Waldemar Świderski
Sensors 2022, 22(22), 8813; https://doi.org/10.3390/s22228813 - 15 Nov 2022
Cited by 20 | Viewed by 4049
Abstract
We built a high-speed TDS setup with the use of electronically controlled optical sampling (ECOPS), which can measure up to 1600 terahertz pulses per second. The movement of the sample was provided by two fast-speed motorized linear stages constituting the gantry. We developed [...] Read more.
We built a high-speed TDS setup with the use of electronically controlled optical sampling (ECOPS), which can measure up to 1600 terahertz pulses per second. The movement of the sample was provided by two fast-speed motorized linear stages constituting the gantry. We developed a flat-bar-based metal marker approach for the synchronization of continuous line-by-line scans. We carefully compared the performance of the terahertz reflection time-domain spectroscopy (TDS) scanner operating in a slow point-by-point and a one-hundred-times faster line-by-line imaging scheme. We analyzed images obtained for both schemes for a uniform metallic breadboard with holes, as well as a glass composite sample with defects. Although the measurement time was reduced by 100 times in terms of the line-by-line scheme, the overall performance in both schemes was almost identical in terms of the defects’ sizes, shapes and locations. The results proved that the proposed ECOPS TDS system can provide uniform and extremely fast scanning without any deterioration in image quality. Full article
(This article belongs to the Special Issue Terahertz Imaging Sensors and Detectors)
Show Figures

Figure 1

27 pages, 3517 KB  
Article
Thermo-Economic Analysis of Innovative Integrated Power Cycles for Low-Temperature Heat Sources Based on Heat Transformer
by Nazila Nematzadeh, Hadi Ghaebi and Ebrahim Abdi Aghdam
Sustainability 2022, 14(20), 13194; https://doi.org/10.3390/su142013194 - 14 Oct 2022
Cited by 3 | Viewed by 2380
Abstract
This paper proposes two novel integrated power cycles as appropriate systems for low-temperature heat sources. The proposed cycles encompass an absorption heat transformer (AHT) system to convert low-temperature heat source to high-temperature source and supply the required heat for driving Kalina cycle (KC) [...] Read more.
This paper proposes two novel integrated power cycles as appropriate systems for low-temperature heat sources. The proposed cycles encompass an absorption heat transformer (AHT) system to convert low-temperature heat source to high-temperature source and supply the required heat for driving Kalina cycle (KC) and absorption power cycle (APC) as bottoming cycles. A comprehensive simulation of the system is presented based on the thermo-economic viewpoint. The results show that the AHT/KC has higher energy and exergy efficiencies than the AHT/APC, with 7.69% and 49.03%, respectively. In addition, the sum unit cost of the product (SUCP) for the system is calculated 87.72 $/GJ. According to the results, throttle valve 1 and absorber 1 are the most destructive components of the AHT/KC and AHT/APC, respectively. The net output power in the AHT/KC and the AHT/APC is assessed 60.06 kW and 34.86 kW, respectively. The circulation rate (CR), Coefficient of performance (COP), and exergetic coefficient of performance (ECOP) for both cycles are 3.819, 0.4108, and 0.6107, respectively. The study of key parameters demonstrates that the energetic performance of the proposed power cycles increases and decreases by a rise in the temperature of the generator and condenser, respectively. From the exergetic perspective, rising temperature of the generator improves the efficiency of the cycles, while increasing the ammonia concentration as well as condenser and absorber temperatures reduce the exergy efficiency. Full article
(This article belongs to the Special Issue Sustainable Energy Economics and Environmental Policy)
Show Figures

Figure 1

17 pages, 3707 KB  
Article
Finite Time Thermodynamic Modeling and Performance Analysis of High-Temperature Proton Exchange Membrane Fuel Cells
by Dongxu Li, Zheshu Ma, Wei Shao, Yanju Li and Xinjia Guo
Int. J. Mol. Sci. 2022, 23(16), 9157; https://doi.org/10.3390/ijms23169157 - 15 Aug 2022
Cited by 12 | Viewed by 3444
Abstract
In order to improve the output performance of high-temperature proton exchange membrane fuel cells (HT-PEMFC), a finite time thermodynamic (FTT) model for HT-PEMFC was established. Several finite time thermodynamic indexes including power density, thermodynamic efficiency, exergy efficiency, exergetic performance efficient (EPC), entropy production [...] Read more.
In order to improve the output performance of high-temperature proton exchange membrane fuel cells (HT-PEMFC), a finite time thermodynamic (FTT) model for HT-PEMFC was established. Several finite time thermodynamic indexes including power density, thermodynamic efficiency, exergy efficiency, exergetic performance efficient (EPC), entropy production rate and ecological coefficient of performance (ECOP) were derived. The energetic performance, exergetic performance and ecological performance of the HT-PEMFC were analyzed under different parameters. Results showed that operating temperature, doping level and thickness of membrane had a significant effect on the performance of HT-PEMFC and the power density increased by 58%, 31.1% and 44.9%, respectively. When the doping level reached 8, the output performance of HT-PEMFC wa optimal. The operating pressure and relative humidity had little influence on the HT-PEMFC and the power density increased by 8.7%% and 17.6%, respectively. Full article
Show Figures

Figure 1

9 pages, 12853 KB  
Article
Kilohertz Pixel-Rate Multilayer Terahertz Imaging of Subwavelength Coatings
by Daniel Molter, Kim-Sophie Ellenberger, Jens Klier, Stefan Duran, Joachim Jonuscheit, Georg von Freymann, Nico Vieweg and Anselm Deninger
Appl. Sci. 2022, 12(10), 4964; https://doi.org/10.3390/app12104964 - 13 May 2022
Cited by 23 | Viewed by 3726
Abstract
The acquisition speed of terahertz time-domain spectroscopy systems has undergone a significant improvement in recent years. With the development of dual-laser-based sampling techniques such as ASOPS or ECOPS, waveform acquisition rates in the kilohertz range have become feasible. Here, we present measurements of [...] Read more.
The acquisition speed of terahertz time-domain spectroscopy systems has undergone a significant improvement in recent years. With the development of dual-laser-based sampling techniques such as ASOPS or ECOPS, waveform acquisition rates in the kilohertz range have become feasible. Here, we present measurements of sub-wavelength layers in multilayer systems at a rate of 1.6 kHz, where the individual layer thicknesses are analyzed in real time. For demonstration, we image layers on metallic and non-metallic disks with a 300 mm diameter, acquiring 240,000 pixels in only 2.5 min. By combining a rotation of the samples with a linear translation of the measurement head, we maximize the measurement yield. Owing to a “single-shot” (625 µs) dynamic range of 40 dB and a bandwidth above 3 THz of the ECOPS system, we achieve sub-micron repeatability for each layer. Full article
(This article belongs to the Special Issue Terahertz Applications for Nondestructive Testing)
Show Figures

Figure 1

15 pages, 2005 KB  
Article
Ecological Performance Optimization of a High Temperature Proton Exchange Membrane Fuel Cell
by Dongxu Li, Siwei Li, Zheshu Ma, Bing Xu, Zhanghao Lu, Yanju Li and Meng Zheng
Mathematics 2021, 9(12), 1332; https://doi.org/10.3390/math9121332 - 9 Jun 2021
Cited by 22 | Viewed by 3474
Abstract
According to finite-time thermodynamics, an irreversible high temperature proton exchange membrane fuel cell (HT-PEMFC) model is established, and the mathematical expressions of the output power, energy efficiency, exergy efficiency and ecological coefficient of performance (ECOP) of HT-PEMFC are deduced. The ECOP is a [...] Read more.
According to finite-time thermodynamics, an irreversible high temperature proton exchange membrane fuel cell (HT-PEMFC) model is established, and the mathematical expressions of the output power, energy efficiency, exergy efficiency and ecological coefficient of performance (ECOP) of HT-PEMFC are deduced. The ECOP is a step forward in optimizing the relationship between power and power dissipation, which is more in line with the principle of ecology. Based on the established HT-PEMFC model, the maximum power density is obtained under different parameters that include operating temperature, operating pressure, phosphoric acid doping level and relative humidity. At the same time, the energy efficiency, exergy efficiency and ECOP corresponding to the maximum power density are acquired so as to determine the optimal value of each index under the maximum power density. The results show that the higher the operating temperature and the doping level, the better the performance of HT-PEMFC is. However, the increase of operating pressure and relative humidity has little effect on HT-PEMFC performance. Full article
(This article belongs to the Special Issue Mathematical Modeling and Simulation in Mechanics and Dynamic Systems)