Sign in to use this feature.

Years

Between: -

Subjects

remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline

Journals

Article Types

Countries / Regions

remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline

Search Results (856)

Search Parameters:
Keywords = Distribution Generation (DG)

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
18 pages, 2954 KiB  
Article
A Multi-Objective Decision-Making Method for Optimal Scheduling Operating Points in Integrated Main-Distribution Networks with Static Security Region Constraints
by Kang Xu, Zhaopeng Liu and Shuaihu Li
Energies 2025, 18(15), 4018; https://doi.org/10.3390/en18154018 - 28 Jul 2025
Viewed by 210
Abstract
With the increasing penetration of distributed generation (DG), integrated main-distribution networks (IMDNs) face challenges in rapidly and effectively performing comprehensive operational risk assessments under multiple uncertainties. Thereby, using the traditional hierarchical economic scheduling method makes it difficult to accurately find the optimal scheduling [...] Read more.
With the increasing penetration of distributed generation (DG), integrated main-distribution networks (IMDNs) face challenges in rapidly and effectively performing comprehensive operational risk assessments under multiple uncertainties. Thereby, using the traditional hierarchical economic scheduling method makes it difficult to accurately find the optimal scheduling operating point. To address this problem, this paper proposes a multi-objective dispatch decision-making optimization model for the IMDN with static security region (SSR) constraints. Firstly, the non-sequential Monte Carlo sampling is employed to generate diverse operational scenarios, and then the key risk characteristics are extracted to construct the risk assessment index system for the transmission and distribution grid, respectively. Secondly, a hyperplane model of the SSR is developed for the IMDN based on alternating current power flow equations and line current constraints. Thirdly, a risk assessment matrix is constructed through optimal power flow calculations across multiple load levels, with the index weights determined via principal component analysis (PCA). Subsequently, a scheduling optimization model is formulated to minimize both the system generation costs and the comprehensive risk, where the adaptive grid density-improved multi-objective particle swarm optimization (AG-MOPSO) algorithm is employed to efficiently generate Pareto-optimal operating point solutions. A membership matrix of the solution set is then established using fuzzy comprehensive evaluation to identify the optimal compromised operating point for dispatch decision support. Finally, the effectiveness and superiority of the proposed method are validated using an integrated IEEE 9-bus and IEEE 33-bus test system. Full article
Show Figures

Figure 1

19 pages, 2649 KiB  
Article
Short-Circuit Current Calculation of Single-Phase to Ground Fault in Petal-Shaped Distribution Network
by Yilong Kang, Huanruo Qi, Rui Liu, Xiangyang Yan, Chen Chen, Fei Guo, Fang Guo and Xiaoxiao Dong
Processes 2025, 13(8), 2393; https://doi.org/10.3390/pr13082393 - 28 Jul 2025
Viewed by 176
Abstract
Petal-shaped distribution networks are receiving increasing attention due to their enhanced reliability. However, the integration of distributed generators (DGs) significantly alters the fault characteristics during single-phase to ground faults. Traditional short-circuit calculation methods become inadequate due to the unmodeled effects of negative sequence [...] Read more.
Petal-shaped distribution networks are receiving increasing attention due to their enhanced reliability. However, the integration of distributed generators (DGs) significantly alters the fault characteristics during single-phase to ground faults. Traditional short-circuit calculation methods become inadequate due to the unmodeled effects of negative sequence current control in DGs. To address this challenge, this study establishes, for the first time, a mathematical model for single-phase to ground faults in a petal-shaped network with DG integration under both positive and negative sequence control. It explicitly derives the DGs’ output current under three control goals: maintaining constant active power, maintaining constant reactive power, and injecting a symmetric three-phase current. Utilizing the symmetrical component method, a composite sequence network incorporating the DGs’ negative sequence current output is developed. Based on the node–voltage relationships, an analytical short-circuit current calculation method suitable for multiple control goals is proposed. Validation via MATLAB R2022a simulations demonstrates high-fidelity accuracy: in Case 1 with different fault locations, the maximum relative error is 0.31%, while in Case 2, it is 2.04%. These results quantify the critical impact of the negative sequence current—reaching up to 14.78% of the DG output during severe voltage sags—providing theoretical support for the protection design of a petal-shaped distribution network with high DG integration. Full article
(This article belongs to the Section Energy Systems)
Show Figures

Figure 1

34 pages, 1593 KiB  
Article
Enhancing Radial Distribution System Performance Through Optimal Allocation and Sizing of Photovoltaic and Wind Turbine Distribution Generation Units with Rüppell’s Fox Optimizer
by Yacine Bouali and Basem Alamri
Mathematics 2025, 13(15), 2399; https://doi.org/10.3390/math13152399 - 25 Jul 2025
Viewed by 176
Abstract
Renewable energy sources are being progressively incorporated into modern power grids to increase sustainability, stability, and resilience. To ensure that residential, commercial, and industrial customers have a dependable and efficient power supply, the transmission system must deliver electricity to end-users via the distribution [...] Read more.
Renewable energy sources are being progressively incorporated into modern power grids to increase sustainability, stability, and resilience. To ensure that residential, commercial, and industrial customers have a dependable and efficient power supply, the transmission system must deliver electricity to end-users via the distribution network. To improve the performance of the distribution system, this study employs distributed generator (DG) units and focuses on determining their optimal placement, sizing, and power factor. A novel metaheuristic algorithm, referred to as Rüppell’s fox optimizer (RFO), is proposed to address this optimization problem under various scenarios. In the first scenario, where the DG operates at unity power factor, it is modeled as a photovoltaic system. In the second and third scenarios, the DG is modeled as a wind turbine system with fixed and optimal power factors, respectively. The performance of the proposed RFO algorithm is benchmarked against five well-known metaheuristic techniques to validate its effectiveness and competitiveness. Simulations are conducted on the IEEE 33-bus and IEEE 69-bus radial distribution test systems to demonstrate the applicability and robustness of the proposed approach. Full article
(This article belongs to the Special Issue Mathematical Methods Applied in Power Systems, 2nd Edition)
Show Figures

Graphical abstract

22 pages, 4670 KiB  
Article
Integrated Carbon Flow Tracing and Topology Reconfiguration for Low-Carbon Optimal Dispatch in DG-Embedded Distribution Networks
by Rao Fu, Guofeng Xia, Sining Hu, Yuhao Zhang, Handaoyuan Li and Jiachuan Shi
Mathematics 2025, 13(15), 2395; https://doi.org/10.3390/math13152395 - 25 Jul 2025
Viewed by 213
Abstract
Addressing the imperative for energy transition amid depleting fossil fuels, distributed generation (DG) is increasingly integrated into distribution networks (DNs). This integration necessitates low-carbon dispatching solutions that reconcile economic and environmental objectives. To bridge the gap between conventional “electricity perspective” optimization and emerging [...] Read more.
Addressing the imperative for energy transition amid depleting fossil fuels, distributed generation (DG) is increasingly integrated into distribution networks (DNs). This integration necessitates low-carbon dispatching solutions that reconcile economic and environmental objectives. To bridge the gap between conventional “electricity perspective” optimization and emerging “carbon perspective” requirements, this research integrated Carbon Emission Flow (CEF) theory to analyze spatiotemporal carbon flow characteristics within DN. Recognizing the limitations of the single-objective approach in balancing multifaceted demands, a multi-objective optimization model was formulated. This model could capture the spatiotemporal dynamics of nodal carbon intensity for low-carbon dispatching while comprehensively incorporating diverse operational economic costs to achieve collaborative low-carbon and economic dispatch in DG-embedded DN. To efficiently solve this complex constrained model, a novel Q-learning enhanced Moth Flame Optimization (QMFO) algorithm was proposed. QMFO synergized the global search capability of the Moth Flame Optimization (MFO) algorithm with the adaptive decision-making of Q-learning, embedding an adaptive exploration strategy to significantly enhance solution efficiency and accuracy for multi-objective problems. Validated on a 16-node three-feeder system, the method co-optimizes switch configurations and DG outputs, achieving dual objectives of loss reduction and carbon emission mitigation while preserving radial topology feasibility. Full article
(This article belongs to the Special Issue Mathematical and Computational Methods for Mechanics and Engineering)
Show Figures

Figure 1

20 pages, 13715 KiB  
Article
Dynamic Reconfiguration for Energy Management in EV and RES-Based Grids Using IWOA
by Hossein Lotfi, Mohammad Hassan Nikkhah and Mohammad Ebrahim Hajiabadi
World Electr. Veh. J. 2025, 16(8), 412; https://doi.org/10.3390/wevj16080412 - 23 Jul 2025
Viewed by 168
Abstract
Effective energy management is vital for enhancing reliability, reducing operational costs, and supporting the increasing penetration of electric vehicles (EVs) and renewable energy sources (RESs) in distribution networks. This study presents a dynamic reconfiguration strategy for distribution feeders that integrates EV charging stations [...] Read more.
Effective energy management is vital for enhancing reliability, reducing operational costs, and supporting the increasing penetration of electric vehicles (EVs) and renewable energy sources (RESs) in distribution networks. This study presents a dynamic reconfiguration strategy for distribution feeders that integrates EV charging stations (EVCSs), RESs, and capacitors. The goal is to minimize both Energy Not Supplied (ENS) and operational costs, particularly under varying demand conditions caused by EV charging in grid-to-vehicle (G2V) and vehicle-to-grid (V2G) modes. To improve optimization accuracy and avoid local optima, an improved Whale Optimization Algorithm (IWOA) is employed, featuring a mutation mechanism based on Lévy flight. The model also incorporates uncertainties in electricity prices and consumer demand, as well as a demand response (DR) program, to enhance practical applicability. Simulation studies on a 95-bus test system show that the proposed approach reduces ENS by 16% and 20% in the absence and presence of distributed generation (DG) and EVCSs, respectively. Additionally, the operational cost is significantly reduced compared to existing methods. Overall, the proposed framework offers a scalable and intelligent solution for smart grid integration and distribution network modernization. Full article
(This article belongs to the Special Issue Power and Energy Systems for E-Mobility, 2nd Edition)
Show Figures

Figure 1

18 pages, 1945 KiB  
Article
Research on an Active Distribution Network Planning Strategy Considering Diversified Flexible Resource Allocation
by Minglei Jiang, Youqing Xu, Dachi Zhang, Yuanqi Liu, Qiushi Du, Xiaofeng Gao, Shiwei Qi and Hongbo Zou
Processes 2025, 13(7), 2254; https://doi.org/10.3390/pr13072254 - 15 Jul 2025
Viewed by 268
Abstract
When planning distributed intelligent power distribution networks, it is necessary to take into account the interests of various distributed generation (DG) operators and power supply enterprises, thereby diversifying and complicating planning models. Additionally, the integration of a high proportion of distributed resources has [...] Read more.
When planning distributed intelligent power distribution networks, it is necessary to take into account the interests of various distributed generation (DG) operators and power supply enterprises, thereby diversifying and complicating planning models. Additionally, the integration of a high proportion of distributed resources has triggered a transformation in the power flow pattern of active distribution networks, shifting from the traditional unidirectional flow mode to a bidirectional interactive mode. The intermittent and fluctuating operation modes of distributed photovoltaic and wind power generation have also increased the difficulty of distribution network planning. To address the aforementioned challenges, this paper proposes an active distribution network planning strategy that considers the allocation of diverse flexible resources, exploring scheduling flexibility from both the power supply side and the load side. Firstly, a bi-level optimization model integrating planning and operation is constructed, where the upper-level model determines the optimal capacity of investment and construction equipment, and the lower-level model formulates an economic dispatching scheme. Through iterative solving of the upper and lower levels, the final planning strategy is determined. Meanwhile, to reduce the complexity of problem-solving, this paper employs an improved PSO-CS hybrid algorithm for iterative optimization. Finally, the effectiveness and feasibility of the proposed algorithm are demonstrated through validation using an improved IEEE-33-bus test system. Compared with conventional algorithms, the convergence speed of the method proposed in this paper can be improved by up to 21.4%, and the total investment cost can be reduced by up to 3.26%. Full article
(This article belongs to the Special Issue Applications of Smart Microgrids in Renewable Energy Development)
Show Figures

Figure 1

20 pages, 3151 KiB  
Article
Distributed Power, Energy Storage Planning, and Power Tracking Studies for Distribution Networks
by Xiaoming Zhang and Jiaming Liu
Electronics 2025, 14(14), 2833; https://doi.org/10.3390/electronics14142833 - 15 Jul 2025
Viewed by 259
Abstract
In recent years, global energy transition has pushed distributed generation (DG) to the forefront in relation to new energy development. Most existing studies focus on DG or energy storage planning but lack co-optimization and power tracking analysis. To address this problem, a multi-objective [...] Read more.
In recent years, global energy transition has pushed distributed generation (DG) to the forefront in relation to new energy development. Most existing studies focus on DG or energy storage planning but lack co-optimization and power tracking analysis. To address this problem, a multi-objective genetic algorithm-based collaborative planning method for photovoltaic (PV) and energy storage is proposed. On this basis, power flow tracking technology is further introduced to conduct a detailed analysis of distributed energy power allocation, providing support for system operation optimization and responsibility sharing. To verify the validity of the model, a 14-node distribution network is used as an example. Voltage stability, PV consumption rate, and economy are taken as objective functions. By solving the three scenarios, it is determined that the introduction of energy storage increases the PV consumption rate from 85.6% to 96.3%; the average network loss for the whole day increases from 1.81 MW to 2.40 MW. Utilizing power tracking techniques, various causes were analyzed; it was found that the placement of energy storage leads to a multidirectional and repetitive flow of power. Full article
Show Figures

Figure 1

26 pages, 3806 KiB  
Article
A Novel Approach for Voltage Stability Assessment and Optimal Siting and Sizing of DGs in Radial Power Distribution Networks
by Salah Mokred, Yifei Wang, Mohammed Alruwaili and Moustafa Ahmed Ibrahim
Processes 2025, 13(7), 2239; https://doi.org/10.3390/pr13072239 - 14 Jul 2025
Viewed by 418
Abstract
The increasing integration of renewable energy sources and the rising demand for electricity has intensified concerns over voltage stability in radial distribution systems. These networks are particularly susceptible to voltage collapse under heavy loading conditions, posing serious system reliability and efficiency risks. Integrating [...] Read more.
The increasing integration of renewable energy sources and the rising demand for electricity has intensified concerns over voltage stability in radial distribution systems. These networks are particularly susceptible to voltage collapse under heavy loading conditions, posing serious system reliability and efficiency risks. Integrating distributed generation (DG) has emerged as a strategic solution to strengthen voltage profiles and reduce power losses. To address this challenge, this study proposes a novel distribution voltage stability index (NDVSI) for accurately assessing voltage stability and guiding optimal DG placement and sizing. The NDVSI provides a reliable tool to identify weak buses and their neighboring nodes that critically impact stability. By targeting these locations, the method ensures DG units are installed where they offer maximum improvement in voltage support and minimum power losses. The approach is implemented using MATLAB R2019a (MathWorks Inc., Natick, MA, USA) and validated on three benchmark radial distribution systems, including IEEE 12-bus, 33-bus, and 69-bus systems, demonstrating its scalability and effectiveness across different grid complexities. Comparative analysis with existing voltage stability indices confirms the superiority of NDVSI in both diagnostic precision and practical application. The proposed approach offers a technically sound and economically viable tool for enhancing the reliability, stability, and performance of modern distribution networks. Full article
(This article belongs to the Section Energy Systems)
Show Figures

Figure 1

35 pages, 2980 KiB  
Review
Artificial Intelligence in Cable Fault Detection and Localization: Recent Advances and Research Challenges
by Qianqiu Shao, Songhai Fan, Zongxi Zhang, Fenglian Liu, Zhengzheng Fu, Pinlei Lv and Zhou Mu
Energies 2025, 18(14), 3662; https://doi.org/10.3390/en18143662 - 10 Jul 2025
Viewed by 468
Abstract
With the large-scale integration of new power systems and distributed generators (DGs), cable fault detection and localization face numerous challenges, where artificial intelligence (AI) techniques demonstrate significant advantages. This review first outlines the causes of cable faults and traditional methods for fault detection [...] Read more.
With the large-scale integration of new power systems and distributed generators (DGs), cable fault detection and localization face numerous challenges, where artificial intelligence (AI) techniques demonstrate significant advantages. This review first outlines the causes of cable faults and traditional methods for fault detection and localization. Subsequently, it comprehensively analyzes the applications of both conventional machine learning and deep learning approaches in this field, elaborating on their application scenarios, strengths, defects, and successful case studies, providing valuable references for researchers and professionals. Additionally, the paper discusses the strengths and limitations of current AI techniques, along with the impacts introduced by DG integration. Finally, it highlights future development trends and potential research directions for advancing AI-based solutions in cable fault detection and localization. Full article
Show Figures

Figure 1

46 pages, 9390 KiB  
Article
Multi-Objective Optimization of Distributed Generation Placement in Electric Bus Transit Systems Integrated with Flash Charging Station Using Enhanced Multi-Objective Grey Wolf Optimization Technique and Consensus-Based Decision Support
by Yuttana Kongjeen, Pongsuk Pilalum, Saksit Deeum, Kittiwong Suthamno, Thongchai Klayklueng, Supapradit Marsong, Ritthichai Ratchapan, Krittidet Buayai, Kaan Kerdchuen, Wutthichai Sa-nga-ngam and Krischonme Bhumkittipich
Energies 2025, 18(14), 3638; https://doi.org/10.3390/en18143638 - 9 Jul 2025
Viewed by 464
Abstract
This study presents a comprehensive multi-objective optimization framework for optimal placement and sizing of distributed generation (DG) units in electric bus (E-bus) transit systems integrated with a high-power flash charging infrastructure. An enhanced Multi-Objective Grey Wolf Optimizer (MOGWO), utilizing Euclidean distance-based Pareto ranking, [...] Read more.
This study presents a comprehensive multi-objective optimization framework for optimal placement and sizing of distributed generation (DG) units in electric bus (E-bus) transit systems integrated with a high-power flash charging infrastructure. An enhanced Multi-Objective Grey Wolf Optimizer (MOGWO), utilizing Euclidean distance-based Pareto ranking, is developed to minimize power loss, voltage deviation, and voltage violations. The framework incorporates realistic E-bus operation characteristics, including a 31-stop, 62 km route, 600 kW pantograph flash chargers, and dynamic load profiles over a 90 min simulation period. Statistical evaluation on IEEE 33-bus and 69-bus distribution networks demonstrates that MOGWO consistently outperforms MOPSO and NSGA-II across all DG deployment scenarios. In the three-DG configuration, MOGWO achieved minimum power losses of 0.0279 MW and 0.0179 MW, and voltage deviations of 0.1313 and 0.1362 in the 33-bus and 69-bus systems, respectively, while eliminating voltage violations. The proposed method also demonstrated superior solution quality with low variance and faster convergence, requiring under 7 h of computation on average. A five-method compromise solution strategy, including TOPSIS and Lp-metric, enabled transparent and robust decision-making. The findings confirm the proposed framework’s effectiveness and scalability for enhancing distribution system performance under the demands of electric transit electrification and smart grid integration. Full article
Show Figures

Figure 1

16 pages, 1842 KiB  
Article
A Fault Recovery Scheme for Active Distribution Networks Based on the Chaotic Binary Sparrow Search Algorithm Considering Operational Risks
by Weijie Huang, Gang Chen, Xiaoming Jiang, Xiong Xiao, Yiyi Chen and Chong Liu
Processes 2025, 13(7), 2128; https://doi.org/10.3390/pr13072128 - 4 Jul 2025
Viewed by 297
Abstract
In order to improve the reliability of power systems with high penetration of distributed generation (DG), this paper proposes a fault recovery scheme for active distribution networks based on the chaotic binary sparrow search algorithm, taking into account the operational risks. First, the [...] Read more.
In order to improve the reliability of power systems with high penetration of distributed generation (DG), this paper proposes a fault recovery scheme for active distribution networks based on the chaotic binary sparrow search algorithm, taking into account the operational risks. First, the connection line is equivalent to the virtual DG, which simplifies the comprehensive power supply recovery problem to a generalized DG-based islanding problem. Secondly, to adequately quantify the risk of islanding during the fault period, the islanding operation risk index is defined from the perspective of power balance and voltage stability. Next, a generalized dynamic islanding strategy for distribution networks considering operational risks is proposed. This strategy can dynamically adjust the island range according to the risk factors, such as DG output, the change of load, and node voltage levels. Then, the multi-objective function is established by comprehensively considering the factors of restoring important loads, the number of switch actions, and the network loss. The binary sparrow search algorithm is used to solve the problem and outputs the optimal fault recovery strategy for the active distribution network. Finally, the simulation experiments and analysis are carried out based on an IEEE40 node distribution network. The simulation experiments and analysis show that the solution speed of the proposed algorithm reaches the second level, which is 10 s to 70 s faster than that of the heuristic and genetic algorithms, and the load recovery rate of the fault recovery strategy is also higher. Full article
(This article belongs to the Special Issue Smart Optimization Techniques for Microgrid Management)
Show Figures

Figure 1

20 pages, 1242 KiB  
Article
A Novel Algorithm for Recovering Out-of-Service Loads in Smart Distribution Systems Following Exposure to Cyber-Attacks
by Mohamed Goda, Mazen Abdel-Salam, Mohamed-Tharwat El-Mohandes and Ahmed Elnozahy
Electronics 2025, 14(13), 2641; https://doi.org/10.3390/electronics14132641 - 30 Jun 2025
Viewed by 190
Abstract
An algorithm is proposed to recover out-of-service loads (OOSLs) in smart distribution systems (SDSs) after exposure to cyber-attacks (CAs) resulting in interruptions of in-service loads (INSLs). The proposed algorithm is implemented in three steps. The first step is based on building the SDS [...] Read more.
An algorithm is proposed to recover out-of-service loads (OOSLs) in smart distribution systems (SDSs) after exposure to cyber-attacks (CAs) resulting in interruptions of in-service loads (INSLs). The proposed algorithm is implemented in three steps. The first step is based on building the SDS in matrix form to be data input to the proposed algorithm. The second step is concerned with classifying the SDS into three zones: the attacked zone, the primary neighbor zone, and the secondary neighbor zone. The third step is performing five maneuvering processes (MPs) to recover the OOSL without breaking the electric limitations (ELs). The ELs are related to the maximum branch current, the node voltage, the load priority, the radiality maintenance of the SDS, the minimum system total power loss, the instruction sequence of the automatic-communication-switches (ACS), and the minimum number of ACSs. The proposed algorithm was tested under a 70-bus SDS with four electric supply feeders. The proposed algorithm achieved supply recovery for all OOSLs with efficiency of 100% after the occurrence of a CA on a single or double ACS without breaking the ELs. The proposed algorithm succeeded in achieving supply recovery for 97.6%, 97.1%, and 96.4% of the OOSLs after the simultaneous occurrence of a CA on three, four, and five ACSs, respectively, without breaking the ELs. The advantages of the proposed algorithm are a lack of dependency on the system size, a short electric supply recovery time within the range of 190–199 ms, a lack of dependency on distributed generation (DG), and the achievement of self-healing in the SDS following a single and two simultaneous CAs, as well as almost achieving self-healing under exposure to three, four, and five simultaneous CAs. Full article
(This article belongs to the Special Issue Cybersecurity for Smart Power Systems and Transmission Networks)
Show Figures

Figure 1

31 pages, 3958 KiB  
Article
Optimal Distributed Generation Mix to Enhance Distribution Network Performance: A Deterministic Approach
by Muhammad Ibrahim Bhatti, Frank Fischer, Matthias Kühnbach, Zohaib Hussain Leghari, Touqeer Ahmed Jumani, Zeeshan Anjum Memon and Muhammad I. Masud
Sustainability 2025, 17(13), 5978; https://doi.org/10.3390/su17135978 - 29 Jun 2025
Viewed by 347
Abstract
Distribution systems’ vulnerability to power losses remains high, among other parts of the power system, due to the high currents and lower voltage ratio. Connecting distributed generation (DG) units can reduce power loss and improve the overall performance of the distribution networks if [...] Read more.
Distribution systems’ vulnerability to power losses remains high, among other parts of the power system, due to the high currents and lower voltage ratio. Connecting distributed generation (DG) units can reduce power loss and improve the overall performance of the distribution networks if sized and located correctly. However, existing studies have usually assumed that DGs operate only at the unity power factor (i.e., type-I DGs) and ignored their dynamic capability to control reactive power, which is unrealistic when optimizing DG allocation in power distribution networks. In contrast, optimizing the allocation of DG units injecting reactive power (type-II), injecting both active and reactive powers (type-III), and injecting active power and dynamically adjusting (absorbing or injecting) reactive power (type-IV) is a more likely approach, which remains unexplored in the current literature. Additionally, various metaheuristic optimization techniques are employed in the literature to optimally allocate DGs in distribution networks. However, the no-free-lunch theorem emphasizes employing novel optimization approaches, as no method is best for all optimization problems. This study demonstrates the potential of optimally allocating different DG types simultaneously to improve power distribution network performance using a parameter-free Jaya optimization technique. The primary objective of optimally allocating DG units is minimizing the distribution network’s power losses. The simulation validation of this study is conducted using the IEEE 33-bus test system. The results revealed that optimally allocating a multiunit DG mix instead of a single DG type significantly reduces power losses. The highest reduction of 96.14% in active power loss was obtained by placing three type-II, two type-III, and three type-IV units simultaneously. In contrast, the minimum loss reduction of 87.26% was observed by jointly allocating one unit of the aforementioned three DG types. Full article
Show Figures

Figure 1

21 pages, 583 KiB  
Article
Discrete-Time Impedance Model-Based Dynamic Analysis and Parameter Design for VSG-Controlled Grid-Forming DG System
by Thiago F. do Nascimento, Josenalde B. Oliveira, Elmer R. L. Villarreal and Andrés O. Salazar
Energies 2025, 18(13), 3400; https://doi.org/10.3390/en18133400 - 27 Jun 2025
Viewed by 255
Abstract
The virtual synchronous generator (VSG) scheme has proven to be an attractive solution in grid-forming converter applications integrated into distributed generation (DG) systems. Thus, this paper presents the dynamic performance of power flow control using the VSG approach under Thevenin impedance variations seen [...] Read more.
The virtual synchronous generator (VSG) scheme has proven to be an attractive solution in grid-forming converter applications integrated into distributed generation (DG) systems. Thus, this paper presents the dynamic performance of power flow control using the VSG approach under Thevenin impedance variations seen by the grid-forming converter. The dynamic analysis is based on a discrete-time model that describes the power flow transient characteristics of the system operating in medium- and high-voltage networks. Based on the proposed model, a controller design procedure for the discrete-time VSG scheme is presented. This methodology aims to assist researchers in implementing VSG control in digital environments. Then, the Thevenin impedance parameters’ influence on the discrete-time VSG strategy dynamic performance is discussed. The VSG technique’s performance in different operating scenarios is assessed by means of simulation results. A case study is provided to validate the effectiveness of the theoretical analysis and the discrete-time VSG control scheme. The results assess the effectiveness of the theoretical analysis performed. Full article
(This article belongs to the Special Issue Advanced Application of Mathematical Methods in Energy Systems)
Show Figures

Figure 1

26 pages, 2752 KiB  
Article
Allocation of Single and Multiple Multi-Type Distributed Generators in Radial Distribution Network Using Mountain Gazelle Optimizer
by Sunday Adeleke Salimon, Ifeoluwa Olajide Fajinmi, Olubunmi Onadayo Onatoyinbo and Oyeniyi Akeem Alimi
Technologies 2025, 13(7), 265; https://doi.org/10.3390/technologies13070265 - 22 Jun 2025
Viewed by 312
Abstract
The growing demand for clean, reliable and efficient power supply has driven the adoption of renewable energy sources in the package of distributed generation (DG) at the distribution segment of the power system. Despite advancements in DG allocation methodologies, a significant research gap [...] Read more.
The growing demand for clean, reliable and efficient power supply has driven the adoption of renewable energy sources in the package of distributed generation (DG) at the distribution segment of the power system. Despite advancements in DG allocation methodologies, a significant research gap exists regarding the simultaneous evaluation of DG sizing, location and power factor optimization, and their economic implications. This study presents the Mountain Gazelle Optimizer (MGO), a recent optimization approach to address the challenges of sizing, locating, and optimizing the power factor of multi-type DG units in a radial distribution network (RDN). In this work, the MGO is employed to reduce voltage variations, reactive power losses, real power losses, and costs while improving the bus voltage in the RDNs. The methodology involves extensive simulations across multiple scenarios covering one to three DG allocations with varying power factors (unity, fixed, and optimal). Key performance metrics evaluated included real and reactive loss reductions, voltage profile index (VPI), voltage stability index (VSI), and cost reductions due to energy losses compared to base cases. The proposed approach was implemented on the standard 33- and 69-bus networks, and the findings demonstrate that the MGO much outperforms other optimization approaches in the existing literature, realizing considerable decreases in real power losses (up to 98.10%) and reactive power losses (up to 93.38%), alongside notable cost savings. This research showcases the critical importance of optimizing DG power factors, a largely neglected aspect in most prior studies. In conclusion, this work fills a vital gap by integrating power factor optimization into the DG allocation framework, offering a comprehensive approach to enhancing the electricity distribution networks’ dependability, efficacy, and sustainability. Full article
(This article belongs to the Special Issue Technological Advances in Science, Medicine, and Engineering 2024)
Show Figures

Figure 1

Back to TopTop