Next Article in Journal
3D Polymer Structures for the Identification of Optimal Dimensions for Cellular Growth for 3D Lung Alveolar Models
Previous Article in Journal
Biodegradable and Transparent PVA/Starch-Based Composite Films for Wound Dressing Applications
 
 
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
Abstract

Mass Sensitivity Analysis of a Newly Developed Quartz Crystal Microbalance with Ring-Dot Electrode Configuration and Reduced Mass Loading Area †

by
Siddharth Swaminathan
* and
Arezoo Emadi
Department of Electrical and Computer Engineering, University of Windsor, Windsor, ON N9B 3P4, Canada
*
Author to whom correspondence should be addressed.
Presented at the 1st International Conference on Micromachines and Applications, 15–30 April 2021; Available online: https://micromachines2021.sciforum.net/.
Published: 14 April 2021
(This article belongs to the Proceedings of The 1st International Conference on Micromachines and Applications)

Abstract

:
Quartz Crystal Microbalance (QCM) is used for detecting microgram level mass changes in gas and liquid phase. Conventional QCM design comprises a circular electrode configuration with an evenly distributed mass loading area. However, their mass sensitivity distribution is found to be non-uniform due to the inherent energy trapping effect. In this paper, the recently developed QCM with a ring electrode and a ring-dot electrode configuration are evaluated. It is shown that this new configuration offers the ability to achieve a uniform mass sensitivity distribution, while attaining a comparable mass sensitivity for a reduced mass loading area. Finite Element Analysis is used to design and evaluate the conventional circular electrode QCM, and the proposed ring electrode and ring-dot electrode QCM configurations, where the mass loading area is reduced by 25% compared with the conventional sensor. Simulations are conducted to determine the sensor’s resonant frequency shifts for an added mass per unit area of 20 μg/mm2. The results indicate that newly designed ring and ring-dot electrode configurations operate at a higher resonant frequency. The observed frequency shift for the designed circular electrode, ring electrode, and ring-dot electrode configurations on a 333 μm thick quartz substrate are 85 kHz, 84 kHz, and 82 kHz, respectively. It is shown that the ring electrode and new ring-dot electrode configurations achieve a higher resonant frequency and offer a comparable sensing performance despite comprising of over 25% reduced mass loading area, in comparison to the conventional circular electrode configuration.

Supplementary Materials

The supplementary file is available online at https://www.mdpi.com/article/10.3390/Micromachines2021-09563.

Institutional Review Board Statement

Not applicable.

Informed Consent Statement

Not applicable.

Data Availability Statement

Not applicable.
Publisher’s Note: MDPI stays neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Share and Cite

MDPI and ACS Style

Swaminathan, S.; Emadi, A. Mass Sensitivity Analysis of a Newly Developed Quartz Crystal Microbalance with Ring-Dot Electrode Configuration and Reduced Mass Loading Area. Eng. Proc. 2021, 4, 32. https://doi.org/10.3390/Micromachines2021-09563

AMA Style

Swaminathan S, Emadi A. Mass Sensitivity Analysis of a Newly Developed Quartz Crystal Microbalance with Ring-Dot Electrode Configuration and Reduced Mass Loading Area. Engineering Proceedings. 2021; 4(1):32. https://doi.org/10.3390/Micromachines2021-09563

Chicago/Turabian Style

Swaminathan, Siddharth, and Arezoo Emadi. 2021. "Mass Sensitivity Analysis of a Newly Developed Quartz Crystal Microbalance with Ring-Dot Electrode Configuration and Reduced Mass Loading Area" Engineering Proceedings 4, no. 1: 32. https://doi.org/10.3390/Micromachines2021-09563

Article Metrics

Back to TopTop