You are currently viewing a new version of our website. To view the old version click .
Engineering Proceedings
  • Abstract
  • Open Access

14 April 2021

Mass Sensitivity Analysis of a Newly Developed Quartz Crystal Microbalance with Ring-Dot Electrode Configuration and Reduced Mass Loading Area †

and
Department of Electrical and Computer Engineering, University of Windsor, Windsor, ON N9B 3P4, Canada
*
Author to whom correspondence should be addressed.
Presented at the 1st International Conference on Micromachines and Applications, 15–30 April 2021; Available online: https://micromachines2021.sciforum.net/.
This article belongs to the Proceedings The 1st International Conference on Micromachines and Applications

Abstract

Quartz Crystal Microbalance (QCM) is used for detecting microgram level mass changes in gas and liquid phase. Conventional QCM design comprises a circular electrode configuration with an evenly distributed mass loading area. However, their mass sensitivity distribution is found to be non-uniform due to the inherent energy trapping effect. In this paper, the recently developed QCM with a ring electrode and a ring-dot electrode configuration are evaluated. It is shown that this new configuration offers the ability to achieve a uniform mass sensitivity distribution, while attaining a comparable mass sensitivity for a reduced mass loading area. Finite Element Analysis is used to design and evaluate the conventional circular electrode QCM, and the proposed ring electrode and ring-dot electrode QCM configurations, where the mass loading area is reduced by 25% compared with the conventional sensor. Simulations are conducted to determine the sensor’s resonant frequency shifts for an added mass per unit area of 20 μg/mm2. The results indicate that newly designed ring and ring-dot electrode configurations operate at a higher resonant frequency. The observed frequency shift for the designed circular electrode, ring electrode, and ring-dot electrode configurations on a 333 μm thick quartz substrate are 85 kHz, 84 kHz, and 82 kHz, respectively. It is shown that the ring electrode and new ring-dot electrode configurations achieve a higher resonant frequency and offer a comparable sensing performance despite comprising of over 25% reduced mass loading area, in comparison to the conventional circular electrode configuration.

Supplementary Materials

The supplementary file is available online at https://www.mdpi.com/article/10.3390/Micromachines2021-09563.

Institutional Review Board Statement

Not applicable.

Data Availability Statement

Not applicable.
Publisher’s Note: MDPI stays neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Article Metrics

Citations

Article Access Statistics

Multiple requests from the same IP address are counted as one view.