Next Article in Journal
Demonstration of an Inline Publication Image Viewer: The Future of Radiological Publishing
Previous Article in Journal
Simultaneous T1 and T2 Brain Relaxometry in Asymptomatic Volunteers Using Magnetic Resonance Fingerprinting
 
 
Tomography is published by MDPI from Volume 7 Issue 1 (2021). Previous articles were published by another publisher in Open Access under a CC-BY (or CC-BY-NC-ND) licence, and they are hosted by MDPI on mdpi.com as a courtesy and upon agreement with Grapho, LLC.
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
Article

Correction of Gradient Nonlinearity Bias in Quantitative Diffusion Parameters of Renal Tissue with Intravoxel Incoherent Motion

by
Dariya I. Malyarenko
1,*,
Yuxi Pang
1,
Julien Senegas
2,
Marko K. Ivancevic
3,
Brian D. Ross
1 and
Thomas L. Chenevert
1
1
Department of Radiology, University of Michigan, Ann Arbor, MI, USA
2
Philips Research Laboratories, Hamburg, Germany
3
Philips Healthcare, Best, The Netherlands
*
Author to whom correspondence should be addressed.
Tomography 2015, 1(2), 145-151; https://doi.org/10.18383/j.tom.2015.00160
Submission received: 3 September 2015 / Revised: 10 October 2015 / Accepted: 12 November 2015 / Published: 1 December 2015

Abstract

Spatially nonuniform diffusion weighting bias as a result of gradient nonlinearity (GNL) causes substantial errors in apparent diffusion coefficient (ADC) maps for anatomical regions imaged distant from the magnet isocenter. Our previously described approach effectively removed spatial ADC bias from 3 orthogonal diffusion-weighted imaging (DWI) measurements for monoexponential media of arbitrary anisotropy. This work evaluates correction feasibility and performance for quantitative diffusion parameters of the 2-component intravoxel incoherent motion (IVIM) model for well-perfused and nearly isotropic renal tissue. Sagittal kidney DWI scans of a volunteer were performed on a clinical 3T magnetic resonance imaging scanner near isocenter and offset superiorly. Spatially nonuniform diffusion weighting caused by GNL resulted both in shifting and broadening of perfusion-suppressed ADC histograms for off-center DWI relative to unbiased measurements close to the isocenter. Direction-average diffusion weighting bias correctors were computed based on the known gradient design provided by the vendor. The computed bias maps were empirically confirmed by coronal DWI measurements for an isotropic gel-flood phantom. Both phantom and renal tissue ADC bias for off-center measurements was effectively removed by applying precomputed 3D correction maps. Comparable ADC accuracy was achieved for corrections of both b maps and DWI intensities in the presence of IVIM perfusion. No significant bias impact was observed for the IVIM perfusion fraction.
Keywords: IVIM diffusion; perfusion-suppressed ADC; nonuniform diffusion weighting; gradient nonlinearity bias IVIM diffusion; perfusion-suppressed ADC; nonuniform diffusion weighting; gradient nonlinearity bias

Share and Cite

MDPI and ACS Style

Malyarenko, D.I.; Pang, Y.; Senegas, J.; Ivancevic, M.K.; Ross, B.D.; Chenevert, T.L. Correction of Gradient Nonlinearity Bias in Quantitative Diffusion Parameters of Renal Tissue with Intravoxel Incoherent Motion. Tomography 2015, 1, 145-151. https://doi.org/10.18383/j.tom.2015.00160

AMA Style

Malyarenko DI, Pang Y, Senegas J, Ivancevic MK, Ross BD, Chenevert TL. Correction of Gradient Nonlinearity Bias in Quantitative Diffusion Parameters of Renal Tissue with Intravoxel Incoherent Motion. Tomography. 2015; 1(2):145-151. https://doi.org/10.18383/j.tom.2015.00160

Chicago/Turabian Style

Malyarenko, Dariya I., Yuxi Pang, Julien Senegas, Marko K. Ivancevic, Brian D. Ross, and Thomas L. Chenevert. 2015. "Correction of Gradient Nonlinearity Bias in Quantitative Diffusion Parameters of Renal Tissue with Intravoxel Incoherent Motion" Tomography 1, no. 2: 145-151. https://doi.org/10.18383/j.tom.2015.00160

Article Metrics

Back to TopTop