You are currently viewing a new version of our website. To view the old version click .
Scientia Pharmaceutica
  • Scientia Pharmaceutica is published by MDPI from Volume 84 Issue 3 (2016). Previous articles were published by another publisher in Open Access under a CC-BY (or CC-BY-NC-ND) licence, and they are hosted by MDPI on mdpi.com as a courtesy and upon agreement with Austrian Pharmaceutical Society (Österreichische Pharmazeutische Gesellschaft, ÖPhG).
  • Article
  • Open Access

9 October 2012

Stress Degradation Behavior of Atorvastatin Calcium and Development of a Suitable Stability-Indicating LC Method for the Determination of Atorvastatin, its Related Impurities, and its Degradation Products

,
and
1
Analytical Research, Custom Pharmaceutical Services, Dr. Reddy’s Laboratories Ltd., Bollaram road, Miyapur, Hyderabad-500049 (AP), India
2
Department of Chemistry, Andhra University, Visakhapatnam-530003, India
*
Author to whom correspondence should be addressed.

Abstract

A rapid, reversed-phase liquid chromatographic method was developed for the quantitative determination of Atorvastatin calcium, its related substances (12 impurities), and degradation impurities in bulk drugs. The chromatographic separation was achieved on a Zorbax Bonus-RP column by employing a gradient elution with water–acetonitrile–trifluoroacetic acid as the mobile phase in a shorter run time of 25 min. The flow rate was 1.0 mL/min and the detection wavelength was 245 nm. The drug substance was subjected to stress studies such as hydrolysis, oxidation, photolysis, and thermal degradation, and considerable degradation was observed in acidic hydrolysis, oxidative, thermal, and photolytic stress conditions. The formed degradation products were reported and were well-resolved from the Atorvastatin and its related substances. The stressed samples were quantified against a qualified reference standard and the mass balance was found to be close to 99.5% (w/w) when the response of the degradant was considered to be equal to the analyte (i.e. Atorvastatin), which demonstrates the stability-indicating capability of the method. The method was validated in agreement with ICH requirements. The method developed here was single and shorter (25 min method for the determination of all 12 related impurities of Atorvastatin and its degradation products), with clearly better resolution and higher sensitivity than the European (85 min method for the determination of six impurities) and United States pharmacopeia (115 min and 55 min, two different methods for the determination of six related substances).

Article Metrics

Citations

Article Access Statistics

Multiple requests from the same IP address are counted as one view.