This is an early access version, the complete PDF, HTML, and XML versions will be available soon.
Open AccessArticle
Gaseous Ammonia Sensing from Liquids via a Portable Chemosensor with Signal Correction for Humidity
1
Department of Chemistry, Materials and Chemical Engineering “G. Natta”, Politecnico di Milano, 20133 Milan, Italy
2
Department of Electronics, Information and Bioengineering, Politecnico di Milano, 20133 Milan, Italy
3
Department of Industrial and Information Engineering, Università degli Studi di Pavia, 27100 Pavia, Italy
*
Author to whom correspondence should be addressed.
Biosensors 2025, 15(7), 407; https://doi.org/10.3390/bios15070407 (registering DOI)
Submission received: 12 May 2025
/
Revised: 17 June 2025
/
Accepted: 21 June 2025
/
Published: 25 June 2025
Abstract
Ammonia (NH3) detection in liquids and biological fluids is essential for monitoring environmental contamination and industrial processes, ensuring food safety, and diagnosing health conditions. Existing detection techniques are often unsuitable for point-of-care (POC) use due to limitations including complex sample handling, lack of portability, and poor compatibility with miniaturized systems. This study introduces a proof-of-concept for a compact, portable device tailored for POC detection of gaseous ammonia released from liquid samples. The device combines a polyaniline (PANI)-based chemoresistive sensor with interdigitated electrodes and a resistance readout circuit, enclosed in a gas-permeable hydrophobic membrane that permits ammonia in the vapor phase only to reach the sensing layer, ensuring selectivity and protection from liquid interference. The ink formulation was optimized. PANI nanoparticle suspension exhibited a monomodal, narrow particle size distribution with an average size of 120 nm and no evidence of larger aggregates. A key advancement of this device is its ability to limit the impact of water vapor, a known source of interference in PANI-based sensors, while maintaining a simple sensor design. A tailored signal processing strategy was implemented, extracting the slope of resistance variation over time as a robust metric for ammonia quantification. The sensor demonstrated reliable performance across a concentration range of 1.7 to 170 ppm with strong logarithmic correlation (R2 = 0.99), and very good linear correlations in low (R2 = 0.96) and high (R2 = 0.97) subranges. These findings validate the feasibility of this POC platform for sensitive, selective, and practical ammonia detection in clinical and environmental applications.
Share and Cite
MDPI and ACS Style
Rescalli, A.; Porello, I.; Cerveri, P.; Cellesi, F.
Gaseous Ammonia Sensing from Liquids via a Portable Chemosensor with Signal Correction for Humidity. Biosensors 2025, 15, 407.
https://doi.org/10.3390/bios15070407
AMA Style
Rescalli A, Porello I, Cerveri P, Cellesi F.
Gaseous Ammonia Sensing from Liquids via a Portable Chemosensor with Signal Correction for Humidity. Biosensors. 2025; 15(7):407.
https://doi.org/10.3390/bios15070407
Chicago/Turabian Style
Rescalli, Andrea, Ilaria Porello, Pietro Cerveri, and Francesco Cellesi.
2025. "Gaseous Ammonia Sensing from Liquids via a Portable Chemosensor with Signal Correction for Humidity" Biosensors 15, no. 7: 407.
https://doi.org/10.3390/bios15070407
APA Style
Rescalli, A., Porello, I., Cerveri, P., & Cellesi, F.
(2025). Gaseous Ammonia Sensing from Liquids via a Portable Chemosensor with Signal Correction for Humidity. Biosensors, 15(7), 407.
https://doi.org/10.3390/bios15070407
Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details
here.
Article Metrics
Article Access Statistics
For more information on the journal statistics, click
here.
Multiple requests from the same IP address are counted as one view.