High-Performance Liquid Chromatography as a Novel Method for the Determination of α-Defensins in Synovial Fluid for Diagnosis of Orthopedic Infections
Abstract
1. Introduction
2. Materials and Methods
2.1. Patients
2.2. HPLC Analysis
2.3. Data Analysis
3. Results
4. Discussion
5. Conclusions
Supplementary Materials
Author Contributions
Funding
Acknowledgments
Conflicts of Interest
References
- Deirmengian, C.; Kardos, K.; Kilmartin, P.; Cameron, A.; Schiller, K.; Parvizi, J. Diagnosing periprosthetic joint infection. Has the era of the biomarker arrived? Clin. Orthop. Relat. Res. 2014, 472, 3254–3262. [Google Scholar] [CrossRef] [PubMed]
- Springer, B.D. The diagnosis of periprosthetic joint infection. J. Arthroplast. 2015, 30, 908–911. [Google Scholar] [CrossRef] [PubMed]
- Ahn, J.K.; Huang, B.; Bae, E.K.; Park, E.J.; Hwang, J.W.; Lee, J.; Koh, E.M.; Cha, H.S. The role of α-defensin-1 and related signal transduction mechanisms in the production of IL-6, IL-8 and MMPs in rheumatoid fibroblast-like synoviocytes. Rheumatology 2013, 52, 1368–1376. [Google Scholar] [CrossRef] [PubMed]
- Deirmengian, C.; Kardos, K.; Kilmartin, P.; Cameron, A.; Schiller, K.; Parvizi, J. Combined measurement of synovial fluid α-defensin and C-reactive protein levels: Highly accurate for diagnosing periprosthetic joint infection. J. Bone Jt. Surg. Am. 2014, 96, 1439–1445. [Google Scholar] [CrossRef] [PubMed]
- Deirmengian, C.; Kardos, K.; Kilmartin, P.; Cameron, A.; Schiller, K.; Booth, R.E., Jr.; Parvizi, J. The alpha-defensin test for periprosthetic joint infection outperforms the leukocyte esterase test strip. Clin. Orthop. Relat. Res. 2015, 473, 198–203. [Google Scholar] [CrossRef] [PubMed]
- Frangiamore, S.J.; Gajewski, N.D.; Saleh, A.; Farias-Kovac, M.; Barsoum, W.K.; Higuera, C.A. α-Defensin accuracy to diagnose periprosthetic joint infection—Best available test? J. Arthroplast. 2016, 31, 456–460. [Google Scholar] [CrossRef]
- Ganz, T. Defensins: Antimicrobial peptides of innate immunity. Nat. Rev. Immunol. 2003, 3, 710–720. [Google Scholar] [CrossRef] [PubMed]
- Lehrer, R.I.; Lu, W. α-Defensins in human innate immunity. Immunol. Rev. 2012, 245, 84–112. [Google Scholar] [CrossRef] [PubMed]
- Wu, Z.; Ericksen, B.; Tucker, K.; Lubkowski, J.; Lu, W. Synthesis and characterization of human α-defensins 4-6. J. Pept. Res. 2004, 64, 118–125. [Google Scholar] [CrossRef] [PubMed]
- Pupaibool, J.; Fulnecky, E.J.; Swords, R.L., Jr.; Sistrunk, W.W.; Haddow, A.D. Alpha-defensin-novel synovial fluid biomarker for the diagnosis of periprosthetic joint infection. Int. Orthop. 2016, 40, 2447–2452. [Google Scholar] [CrossRef] [PubMed]
- Berger, P.; Van Cauter, M.; Driesen, R.; Neyt, J.; Cornu, O.; Bellemans, J. Diagnosis of prosthetic joint infection with alpha-defensin using a lateral flow device: A multicentre study. Bone Jt. J. 2017, 99, 1176–1182. [Google Scholar] [CrossRef] [PubMed]
- Gehrke, T.; Lausmann, C.; Citak, M.; Bonanzinga, T.; Frommelt, L.; Zahar, A. The accuracy of the alpha defensin lateral flow device for diagnosis of periprosthetic joint infection: Comparison with a gold standard. J. Bone Jt. Surg. Am. 2018, 100, 42–48. [Google Scholar] [CrossRef] [PubMed]
- Bonanzinga, T.; Zahar, A.; Dütsch, M.; Lausmann, C.; Kendoff, D.; Gehrke, T. How reliable is the alpha-defensin immunoassay test for diagnosing periprosthetic joint infection? A prospective study. Clin. Orthop. Relat. Res. 2017, 475, 408–415. [Google Scholar] [CrossRef] [PubMed]
- Sigmund, I.K.; Holinka, J.; Gamper, J.; Staats, K.; Böhler, C.; Kubista, B.; Windhager, R. Qualitative α-defensin test (Synovasure) for the diagnosis of periprosthetic infection in revision total joint arthroplasty. Bone Jt. J. 2017, 99, 66–72. [Google Scholar] [CrossRef] [PubMed]
- Sigmund, I.K.; Yermak, K.; Perka, C.; Trampuz, A. Is the enzyme-linked immunosorbent assay more accurate than the lateral flow alpha defensin test for diagnosing periprosthetic joint infection? Clin. Orthop. Relat. Res. 2018, 476, 1645–1654. [Google Scholar] [CrossRef] [PubMed]
- Kanwar, S.; Al-Mansoori, A.A.; Chand, M.R.; Villa, J.M.; Suarez, J.C.; Patel, P.D. What is the optimal criteria to use for detecting periprosthetic joint infections before total joint arthroplasty? J. Arthroplast. 2018, 33, S201–S204. [Google Scholar] [CrossRef]
- Parvizi, J.; Gehrke, T. Definition of periprosthetic joint infection. J. Arthroplast. 2014, 29, 1331. [Google Scholar] [CrossRef]
- Zmistowski, B.; Della Valle, C.; Bauer, T.W.; Malizos, K.N.; Alavi, A.; Bedair, H.; Booth, R.E.; Choong, P.; Deirmengian, C.; Ehrlich, G.D.; et al. Diagnosis of Periprosthetic Joint Infection. J. Orthop. Res. 2014, 32, S98–S107. [Google Scholar] [CrossRef]
- de Saint Vincent, B.; Migaud, H.; Seneeville, E.; Loiez, C.; Pasquier, G.; Girard, J.; Putman, S. Diagnostic accuracy of the alpha defensin lateral flow device (Synovasure) for periprosthetic infections in microbiologically complex situations: A study of 42 cases in a French referral centre. Orthop. Traumatol. Surg. Res. 2018, 148, 427–431. [Google Scholar] [CrossRef]
- Kasparek, M.F.; Kasparek, M.; Boettner, F.; Faschingbauer, M.; Hahne, J.; Dominkus, M. Intraoperative diagnosis of periprosthetic joint infection using a novel alpha-defensin lateral flow assay. J. Arthroplast. 2016, 31, 2871–2874. [Google Scholar] [CrossRef]
- Scholten, R.; Visser, J.; van Susante, J.L.C.; van Loon, C.J.M. Low sensitivity of α-defensin (Synovasure) test for intraoperative exclusion of prosthetic joint infection. Acta Orthop. 2018, 89, 357–359. [Google Scholar] [CrossRef] [PubMed]
- Partridge, D.G.; Gordon, A.; Townsend, R. False-positive synovial fluid alpha-defensin test in patient with acute gout affecting a prosthetic knee. Eur. J. Orthop. Surg. Traumatol. 2017, 27, 549–551. [Google Scholar] [CrossRef] [PubMed]
- Paulsen, F.; Pufe, T.; Conradi, L.; Varoga, D.; Tsokos, M.; Papendieck, J.; Petersen, W. Antimicrobial peptides are expressed and produced in healthy and inflamed human synovial membranes. J. Pathol. 2002, 198, 369–377. [Google Scholar] [CrossRef] [PubMed]
- Ahmad, S.S.; Hirschmann, M.T.; Becker, R.; Shaker, A.; Ateschrang, A.; Keel, M.J.B.; Albers, C.E.; Buetikofer, L.; Maqungo, S.; Stöckle, U.; et al. A meta-analysis of synovial biomarkers in periprosthetic joint infection: Synovasure™ is less effective than the ELISA-based alpha-defensin test. Knee Surg. Sports Traumatol. Arthrosc. 2018, 26, 3039–3047. [Google Scholar] [CrossRef] [PubMed]
Patient | Cultivation | PCR | AD by HPLC | Diagnosis |
---|---|---|---|---|
1 | neg. | pos. | pos. | IA |
2 | neg. | pos. | pos. | IA |
3 | neg. | pos. | pos. | IA |
4 | neg. | neg. | pos. | IA |
5 | neg. | pos. | pos. | IA |
6 | neg. | pos. | pos. | IA |
7 | pos. | pos. | pos. | PJI |
8 | neg. | pos. | pos. | PJI |
9 | pos. | pos. | pos. | PJI |
10 | neg. | pos. | pos. | PJI |
11 | neg. | pos. | pos. | PJI |
12 | neg. | pos. | pos. | PJI |
13 | neg. | neg. | pos. | PJI |
14 | neg. | neg. | neg. | TEP * |
15 | neg. | pos. | neg. | TEP * |
16 | neg. | neg. | neg. | TEP * |
17 | neg. | neg. | neg. | TEP * |
18 | neg. | neg. | neg. | TEP * |
19 | neg. | neg. | pos. | REA * |
20 | neg. | neg. | neg. | REA * |
21 | neg. | neg. | neg. | RHA * |
22 | neg. | neg. | neg. | AR * |
23 | neg. | neg. | neg. | AR * |
24 | neg. | neg. | neg. | AR * |
Viewpoint | Synovasure® PJI Test (Lateral Flow Device) | ELISA | HPLC |
---|---|---|---|
α-defensins | Sum of HNP1–3 | HNP1, HNP3, or sum of HNP1–3 | Sum of HNP1–3 |
Type of examination | Diagnostic device | Laboratory exam using diagnostic kit | Laboratory exam using instrument |
Test output | Presence/absence of PJI | Exact concentration of single α-defensin | Exact concentration of the sum of α-defensins |
Time to result | Within 10 min | Within hours | Within 1 h |
Cost | Expensive | Less expensive | Low cost |
Cutoff concentration | 5.2 mg/L a, 7.72 mg/L b only for PJI | 5.2 mg/L c only for PJI | 38 mg/L for PJI 98 mg/L for IA |
Blood in sample | If hemoglobin exceeds 0.5 g/dL, result is affected | Does not affect result | Does not affect result d |
© 2020 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
Share and Cite
Melicherčík, P.; Klapková, E.; Kotaška, K.; Jahoda, D.; Landor, I.; Čeřovský, V. High-Performance Liquid Chromatography as a Novel Method for the Determination of α-Defensins in Synovial Fluid for Diagnosis of Orthopedic Infections. Diagnostics 2020, 10, 33. https://doi.org/10.3390/diagnostics10010033
Melicherčík P, Klapková E, Kotaška K, Jahoda D, Landor I, Čeřovský V. High-Performance Liquid Chromatography as a Novel Method for the Determination of α-Defensins in Synovial Fluid for Diagnosis of Orthopedic Infections. Diagnostics. 2020; 10(1):33. https://doi.org/10.3390/diagnostics10010033
Chicago/Turabian StyleMelicherčík, Pavel, Eva Klapková, Karel Kotaška, David Jahoda, Ivan Landor, and Václav Čeřovský. 2020. "High-Performance Liquid Chromatography as a Novel Method for the Determination of α-Defensins in Synovial Fluid for Diagnosis of Orthopedic Infections" Diagnostics 10, no. 1: 33. https://doi.org/10.3390/diagnostics10010033
APA StyleMelicherčík, P., Klapková, E., Kotaška, K., Jahoda, D., Landor, I., & Čeřovský, V. (2020). High-Performance Liquid Chromatography as a Novel Method for the Determination of α-Defensins in Synovial Fluid for Diagnosis of Orthopedic Infections. Diagnostics, 10(1), 33. https://doi.org/10.3390/diagnostics10010033