Next Article in Journal
The Influence of Gravity Waves on Ice Saturation in the Tropical Tropopause Layer over Darwin, Australia
Previous Article in Journal
Modified Three-Dimensional Jet Indices and Their Application to East Asia
Previous Article in Special Issue
Influence of the Airflow in a Solar Passive Building on the Indoor Air Quality and Thermal Comfort Levels
Open AccessArticle

Radon Investigation in 650 Energy Efficient Dwellings in Western Switzerland: Impact of Energy Renovation and Building Characteristics

1
Human-Oriented Built Environment Lab, School of Architecture, Civil and Environmental Engineering, École Polytechnique Fédérale de Lausanne, CH-1015 Lausanne, Switzerland
2
Transform Institute, Western Swiss Centre for Indoor Air Quality and Radon (croqAIR), School of Engineering and Architecture of Fribourg, HES-SO University of Applied Sciences and Arts Western Switzerland, CH-1700 Fribourg, Switzerland
3
HumanTech Institute, School of Engineering and Architecture of Fribourg, HES-SO University of Applied Sciences and Arts Western Switzerland, CH-1700 Fribourg, Switzerland
4
Department Health, Work and Environment, Center for Primary Care and Public Health (Unisanté), University of Lausanne, CH-1066 Epalinges, Switzerland
5
TOXpro SA, CH-1227 Carouge, Switzerland
*
Author to whom correspondence should be addressed.
Atmosphere 2019, 10(12), 777; https://doi.org/10.3390/atmos10120777
Received: 8 November 2019 / Revised: 28 November 2019 / Accepted: 29 November 2019 / Published: 4 December 2019
(This article belongs to the Special Issue Green Buildings and Indoor Air Quality)
As part of more stringent energy targets in Switzerland, we witness the appearance of new green-certified dwellings while many existing dwellings have undergone energy efficiency measures. These measures have led to reduced energy consumption, but rarely consider their impact on indoor air quality. Consequently, such energy renovation actions can lead to an accumulation of radon in dwellings located in radon-prone areas at doses that can affect human health. This study compared the radon levels over 650 energy-efficient dwellings in western Switzerland between green-certified (Minergie) and energy-renovated dwellings, and analyzed the building characteristics responsible of this accumulation. We found that the newly green-certified dwellings had significantly lower radon level than energy-renovated, which were green- and non-green-certified houses (geometric mean 52, 87, and 105 Bq/m3, respectively). The new dwellings with integrated mechanical ventilation exhibited lower radon concentrations. Thermal retrofitting of windows, roofs, exterior walls, and floors were associated with a higher radon level. Compared to radon measurements prior to energy renovation, we found a 20% increase in radon levels. The results highlight the need to consider indoor air quality when addressing energy savings to avoid compromising occupants’ health, and are useful for enhancing the ventilation design and energy renovation procedures in dwellings.
Keywords: dwellings; indoor air quality; energy efficiency; building characteristics; thermal retrofitting dwellings; indoor air quality; energy efficiency; building characteristics; thermal retrofitting