Sign in to use this feature.

Years

Between: -

Subjects

remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline

Journals

Article Types

Countries / Regions

Search Results (24)

Search Parameters:
Keywords = syngo.via

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
16 pages, 1446 KB  
Article
Cross-Software Radiomic Feature Robustness Assessed by Hierarchical Clustering and Composite Index Analysis: A Multi-Cancer Study on Colorectal and Liver Lesions
by Roberta Fusco, Giulia Festa, Mario Sansone, Sergio Venanzio Setola, Antonio Avallone, Francesco Izzo, Antonella Petrillo and Vincenza Granata
Bioengineering 2025, 12(12), 1282; https://doi.org/10.3390/bioengineering12121282 - 21 Nov 2025
Cited by 1 | Viewed by 1101
Abstract
Background: Radiomic feature robustness is a key prerequisite for the reproducibility and clinical translation of imaging biomarkers. Variability across software platforms can significantly affect feature consistency, compromising predictive modeling reliability. This study aimed to develop and validate a hierarchical clustering-based workflow for evaluating [...] Read more.
Background: Radiomic feature robustness is a key prerequisite for the reproducibility and clinical translation of imaging biomarkers. Variability across software platforms can significantly affect feature consistency, compromising predictive modeling reliability. This study aimed to develop and validate a hierarchical clustering-based workflow for evaluating radiomic feature robustness within and across software platforms, identifying stable and reproducible features suitable for clinical applications. Methods: A multi-cancer CT dataset including 97 lesions from 71 patients, comprising primary colorectal cancer (CRC), colorectal liver metastases, and hepatocellular carcinoma (HCC), was analyzed. Radiomic features were extracted using two IBSI-compliant platforms (MM Radiomics of syngo.via Frontier and 3D Slicer with PyRadiomics). Intra-software reliability was assessed through the intraclass correlation coefficient ICC(A,1), while cross-software stability was evaluated using hierarchical clustering validated by the Adjusted Rand Index (ARI). A Composite Index (CI) integrating correlation, distributional similarity, and mean fractional ratio quantified inter-platform feature robustness. Results: Over 95% of radiomic features demonstrated good-to-excellent intra-software reliability. Several clustering configurations achieved ARI = 1.0, confirming strong cross-platform concordance. The most robust and recurrent features were predominantly wavelet-derived descriptors and first-order statistics, particularly cluster shade (GLCM-based) and mean intensity-related features. Conclusions: The proposed multi-stage framework effectively identifies stable, non-redundant, and transferable radiomic features across IBSI-compliant software platforms. These findings provide a methodological foundation for cross-platform harmonization and enhance the reproducibility of radiomic biomarkers in oncologic imaging. Full article
(This article belongs to the Special Issue AI-Driven Imaging and Analysis for Biomedical Applications)
Show Figures

Figure 1

15 pages, 3027 KB  
Article
Artificial Intelligence as a Diagnostic Tool in Preoperative Surgical Planning for Early Non-Small Cell Lung Cancer: A Single-Center Experience
by Zeljko Garabinovic, Milan Savic, Nikola Colic, Jelena Rakocevic, Maja Ercegovac, Milos Mitrovic, Katarina Lukic, Jelica Vukmirovic, Jelena Vasic Madzarevic, Stefan Stevanovic, Gordana Bisevac Peric, Miljana Bubanja and Aleksandra Pavic
J. Clin. Med. 2025, 14(21), 7609; https://doi.org/10.3390/jcm14217609 - 27 Oct 2025
Cited by 1 | Viewed by 1267
Abstract
Background: Lung cancer remains the leading cause of cancer-related mortality worldwide, with non-small cell lung cancer (NSCLC) accounting for the majority of cases. Radiomics and artificial intelligence (AI) have emerged as promising tools for quantitative imaging analysis and precision staging. This study [...] Read more.
Background: Lung cancer remains the leading cause of cancer-related mortality worldwide, with non-small cell lung cancer (NSCLC) accounting for the majority of cases. Radiomics and artificial intelligence (AI) have emerged as promising tools for quantitative imaging analysis and precision staging. This study aimed to evaluate the ability of an AI-based radiomics model to preoperatively predict tumor (T) and nodal (N) stage, lymphovascular invasion (LVI), and postoperative complications in patients with early-stage NSCLC. Material and Methods: This retrospective study included 51 consecutive patients who underwent anatomical lobectomy with systematic lymph node dissection between 2019 and 2024, at the Clinic for Thoracic Surgery of the University Clinical Center of Serbia. Quantitative imaging features were extracted from preoperative CT scans using the Lesion Scout with Auto ID module (syngo.via VB50 MM, Siemens Healthineers). Radiomics and clinical predictors were analyzed using regularized logistic regression (LASSO) with five-fold cross-validation. Model performance was assessed using AUC, accuracy, sensitivity, specificity, precision, and F1 score, and calibration was evaluated using the Hosmer–Lemeshow test. Groups were compared using parametric and non-parametric tests. Correlation between the variables was assessed using Spearman’s rank correlation coefficient. All p-values less than 0.05 were considered significant. Results: The AI-based model showed excellent performance for predicting the T component (training AUC = 0.89; test AUC = 0.86; F1 = 0.81) and acceptable calibration (p = 0.41). Nodal metastasis (OR = 0.108; 95% CI: 0.011–1.069; p = 0.057) and LVI (OR = 0.519; 95% CI: 0.139–1.937; p = 0.329) were not significantly predicted. Emphysema was identified as a significant independent predictor of postoperative complications (χ2 = 5.13; p = 0.024). Conclusions: The AI-driven radiomics model demonstrated strong predictive ability for the T component and identified emphysema as a clinically relevant predictor of postoperative complications. Full article
Show Figures

Figure 1

13 pages, 2979 KB  
Article
Predictive Value of 99mTc DPD Bone SPECT/CT Uptake Ratio for Culture Results in Lower Limb Osteomyelitis
by Hyun Suk Shin and Min Bom Kim
Diagnostics 2025, 15(16), 2109; https://doi.org/10.3390/diagnostics15162109 - 21 Aug 2025
Cited by 2 | Viewed by 1477
Abstract
Background/Objectives: The diagnosis of osteomyelitis is typically based on clinical suspI icion supported by imaging and lab findings. Various nuclear medicine imaging, including bone SPECT/CT, is emerging as an effective tool to guide the diagnosis of osteomyelitis. This study investigates whether the [...] Read more.
Background/Objectives: The diagnosis of osteomyelitis is typically based on clinical suspI icion supported by imaging and lab findings. Various nuclear medicine imaging, including bone SPECT/CT, is emerging as an effective tool to guide the diagnosis of osteomyelitis. This study investigates whether the preoperative 99mTc DPD bone SPECT/CT uptake \ratio correlates with intraoperative tissue culture positivity in patients with suspected lower extremity osteomyelitis. Methods: We retrospectively reviewed 46 patients who underwent surgery for suspected osteomyelitis of the lower extremity between February 2020 and May 2025. Bone SPECT/CT was performed using 99mTc DPD, and uptake values were measured using Syngo.via software. Lesion-to-Background Ratio (LBR) was calculated by comparing uptake in the lesion with the contralateral bone. Intraoperative culture was conducted at the region with high uptake in SPECT/CT. Results: Among the 46 patients who underwent surgery, 28 had positive tissue cultures, and 18 were negative. The mean LBR was significantly higher in culture-positive cases (14.5 ± 4.5) than in culture-negative cases (6.8 ± 8.0, p = 0.0002) Inflammatory markers (WBC, ANC, ESR, CRP) and the antibiotic-free interval before surgery did not significantly differ between groups or correlate with LBR. ROC analysis identified an LBR threshold of 9.44, yielding a sensitivity of 71.4% and specificity of 88.9% for predicting positive cultures (AUC = 0.81). Conclusions: 99mTc DPD bone SPECT/CT uptake ratio may serve as a useful tool for the preoperative assessment of suspected lower extremity osteomyelitis, providing a more reliable prediction of intraoperative microbial culture results compared to serum inflammatory markers or the duration of antibiotic-free intervals. High tracer uptake may also be observed in various other conditions and thus should be interpreted in a multidisciplinary context in conjunction with other modalities. Full article
(This article belongs to the Special Issue Diagnostic Imaging in Musculoskeletal Diseases)
Show Figures

Figure 1

16 pages, 1873 KB  
Article
Coronary Artery Inflammation and Epicardial Adipose Tissue Volume in Relation with Atrial Fibrillation Development
by Renáta Gerculy, Imre Benedek, István Kovács, Nóra Rat, Ioana-Patricia Rodean, Botond Barna Mátyás, Emanuel Blîndu, Delia Păcurar, Ciprian-Gelu Grigoroaea and Theodora Benedek
Diagnostics 2025, 15(16), 2003; https://doi.org/10.3390/diagnostics15162003 - 11 Aug 2025
Cited by 5 | Viewed by 1386
Abstract
Background/Objectives: Atrial fibrillation (AF) is associated with increased epicardial adipose tissue (EAT), atrial dilation, and coronary inflammation, though causality remains unclear. Cardiac computed tomography (CCT) allows for precise quantification of EAT volume and the left atrial volume index (LAVI), along with the calculation [...] Read more.
Background/Objectives: Atrial fibrillation (AF) is associated with increased epicardial adipose tissue (EAT), atrial dilation, and coronary inflammation, though causality remains unclear. Cardiac computed tomography (CCT) allows for precise quantification of EAT volume and the left atrial volume index (LAVI), along with the calculation of the fat attenuation index (FAI), indicating coronary inflammation. Combined with the Coronary Artery Disease-Reporting and Data System (CAD-RADS), these imaging markers may improve AF risk stratification. This study evaluates the association between peri-atrial EAT volumes, LAVI, CAD-RADS, and FAI scores in AF patients using advanced AI platforms. Methods: This retrospective study analyzed 122 patients presenting with angina-type pain and a low-to-intermediate likelihood of CAD, who underwent CCT. Patients were divided into two groups based on rhythm status: 42 with AF and 80 without AF. Total EAT, left atrial (LA-EAT), and bi-atrial EAT (BA-EAT) volumes were assessed, along with LAV, CAD-RADS classification, and FAI scores measured using CaRi-Heart® and syngo.via Frontier®. Results: AF patients exhibited significantly higher EAT volumes (total EAT: 231.8 ± 45.85 vs. 153.2 ± 54.14 mL, p < 0.0001; LA-EAT: 23.55 ± 6.44 vs. 15.54 ± 8.49 mL, p < 0.0001; BA-EAT: 50.24 ± 12.69 vs. 39.84 ± 15.70 mL, p = 0.0002) and elevated LAVI values (57.7 ± 11.44 vs. 45.9 ± 12.58 mL/m2, p < 0.0001). ROC analyses confirmed strong diagnostic performance of total EAT (AUC = 0.869), LA-EAT (AUC = 0.776), BA-EAT (AUC = 0.703), and the LAVI (AUC = 0.756). Higher CAD-RADS categories (2–5) were more frequent in AF, although significant differences were observed only in the lowest category (0–1; 26.2% AF vs. 47.8% non-AF, p = 0.032). Total FAI scores were also higher in AF patients (14.83 ± 10.16 vs. 12.37 ± 7.89, p = 0.044). Conclusions: Increased EAT volumes, an elevated LAVI, and higher FAI scores are significantly associated with AF, suggesting a combined structural and inflammatory substrate. EAT, the LAVI, the FAI, and CAD-RADS collectively represent valuable non-invasive imaging biomarkers for early AF risk assessment. Full article
Show Figures

Figure 1

13 pages, 2547 KB  
Article
Improving Diagnostic Robustness of Perfusion MRI in Brain Metastases: A Focus on 3D ROI Techniques and Automatic Thresholding
by Stéphanie Rudzinska-Mistarz, Brieg Dissaux, Laurie Marchi, Anne-Charlotte Roux, Alexis Perrot, François Lucia, Romuald Seizeur, Olivier Pradier, Gurvan Dissaux, Moncef Morjani and Vincent Bourbonne
Cancers 2025, 17(13), 2085; https://doi.org/10.3390/cancers17132085 - 22 Jun 2025
Cited by 1 | Viewed by 2000
Abstract
Background: Distinguishing tumor recurrence from radiation necrosis after radiotherapy for brain metastases remains a major diagnostic challenge. Perfusion MRI, particularly the measurement of relative cerebral blood volume (rCBV), is a commonly used technique to differentiate between these two entities. However, variations in [...] Read more.
Background: Distinguishing tumor recurrence from radiation necrosis after radiotherapy for brain metastases remains a major diagnostic challenge. Perfusion MRI, particularly the measurement of relative cerebral blood volume (rCBV), is a commonly used technique to differentiate between these two entities. However, variations in the placement of regions of interest (ROIs) affect diagnostic accuracy. This study compares the diagnostic performance of different cerebral perfusion methods, including a novel volumetric 3D ROI method and automatic thresholding, to differentiate tumor recurrence from radiation necrosis. Methods: We retrospectively analyzed data from 23 patients, including 25 brain metastases treated with stereotactic radiotherapy, who were suspected of local recurrence and had histological confirmation via biopsy or surgical resection. Each patient underwent perfusion MRI before surgery. The diagnostic performance of the different ROI methods (manual and 3D) was evaluated using the area under the ROC curve (AUC), as well as sensitivity and specificity measures. An automatic thresholding method was also applied, generating tumor sub-volumes with predefined cut-off values to determine the rCBV threshold most specific for differentiating relapse from necrosis. Results: The 3D ROI method, considering the whole lesion and a healthy ROI in the head of the caudate nucleus, demonstrated superior diagnostic performance (AUC = 0.65), outperforming manual methods (AUC = 0.53). Robustness was moderate, with an intraclass correlation coefficient of 0.60 between Syngo.via and IntelliSpace. Conclusions: The 3D ROI method shows promise in improving diagnostic accuracy in distinguishing tumor recurrence from radiation necrosis. Further studies with standardized protocols and larger populations are needed to validate these results. Full article
(This article belongs to the Special Issue Radiation Therapy for Brain Tumors)
Show Figures

Figure 1

26 pages, 1223 KB  
Systematic Review
Performance of Commercial Deep Learning-Based Auto-Segmentation Software for Prostate Cancer Radiation Therapy Planning: A Systematic Review
by Curtise K. C. Ng
Information 2025, 16(3), 215; https://doi.org/10.3390/info16030215 - 11 Mar 2025
Cited by 7 | Viewed by 4064
Abstract
As yet, there is no systematic review focusing on benefits and issues of commercial deep learning-based auto-segmentation (DLAS) software for prostate cancer (PCa) radiation therapy (RT) planning despite that NRG Oncology has underscored such necessity. This article’s purpose is to systematically review commercial [...] Read more.
As yet, there is no systematic review focusing on benefits and issues of commercial deep learning-based auto-segmentation (DLAS) software for prostate cancer (PCa) radiation therapy (RT) planning despite that NRG Oncology has underscored such necessity. This article’s purpose is to systematically review commercial DLAS software product performances for PCa RT planning and their associated evaluation methodology. A literature search was performed with the use of electronic databases on 7 November 2024. Thirty-two articles were included as per the selection criteria. They evaluated 12 products (Carina Medical LLC INTContour (Lexington, KY, USA), Elekta AB ADMIRE (Stockholm, Sweden), Limbus AI Inc. Contour (Regina, SK, Canada), Manteia Medical Technologies Co. AccuContour (Jian Sheng, China), MIM Software Inc. Contour ProtégéAI (Cleveland, OH, USA), Mirada Medical Ltd. DLCExpert (Oxford, UK), MVision.ai Contour+ (Helsinki, Finland), Radformation Inc. AutoContour (New York, NY, USA), RaySearch Laboratories AB RayStation (Stockholm, Sweden), Siemens Healthineers AG AI-Rad Companion Organs RT, syngo.via RT Image Suite and DirectORGANS (Erlangen, Germany), Therapanacea Annotate (Paris, France), and Varian Medical Systems, Inc. Ethos (Palo Alto, CA, USA)). Their results illustrate that the DLAS products can delineate 12 organs at risk (abdominopelvic cavity, anal canal, bladder, body, cauda equina, left (L) and right (R) femurs, L and R pelvis, L and R proximal femurs, and sacrum) and four clinical target volumes (prostate, lymph nodes, prostate bed, and seminal vesicle bed) with clinically acceptable outcomes, resulting in delineation time reduction, 5.7–81.1%. Although NRG Oncology has recommended each clinical centre to perform its own DLAS product evaluation prior to clinical implementation, such evaluation seems more important for AccuContour and Ethos due to the methodological issues of the respective single studies, e.g., small dataset used, etc. Full article
Show Figures

Figure 1

19 pages, 3744 KB  
Article
In-House Fabrication and Validation of 3D-Printed Custom-Made Medical Devices for Planning and Simulation of Peripheral Endovascular Therapies
by Arianna Mersanne, Ruben Foresti, Chiara Martini, Cristina Caffarra Malvezzi, Giulia Rossi, Anna Fornasari, Massimo De Filippo, Antonio Freyrie and Paolo Perini
Diagnostics 2025, 15(1), 8; https://doi.org/10.3390/diagnostics15010008 - 25 Dec 2024
Cited by 3 | Viewed by 2799
Abstract
Objectives: This study aims to develop and validate a standardized methodology for creating high-fidelity, custom-made, patient-specific 3D-printed vascular models that serve as tools for preoperative planning and training in the endovascular treatment of peripheral artery disease (PAD). Methods: Ten custom-made 3D-printed vascular models [...] Read more.
Objectives: This study aims to develop and validate a standardized methodology for creating high-fidelity, custom-made, patient-specific 3D-printed vascular models that serve as tools for preoperative planning and training in the endovascular treatment of peripheral artery disease (PAD). Methods: Ten custom-made 3D-printed vascular models were produced using computed tomography angiography (CTA) scans of ten patients diagnosed with PAD. CTA images were analyzed using Syngo.via by a specialist to formulate a medical prescription that guided the model’s creation. The CTA data were then processed in OsiriX MD to generate the .STL file, which is further refined in a Meshmixer. Stereolithography (SLA) 3D printing technology was employed, utilizing either flexible or rigid materials. The dimensional accuracy of the models was evaluated by comparing their CT scan images with the corresponding patient data, using OsiriX MD. Additionally, both flexible and rigid models were evaluated by eight vascular surgeons during simulations in an in-house-designed setup, assessing both the technical aspects and operator perceptions of the simulation. Results: Each model took approximately 21.5 h to fabricate, costing €140 for flexible and €165 for rigid materials. Bland–Alman plots revealed a strong agreement between the 3D models and patient anatomy, with outliers ranging from 4.3% to 6.9%. Simulations showed that rigid models performed better in guidewire navigation and catheter stability, while flexible models offered improved transparency and lesion treatment. Surgeons confirmed the models’ realism and utility. Conclusions: The study highlights the cost-efficient, high-fidelity production of 3D-printed vascular models, emphasizing their potential to enhance training and planning in endovascular surgery. Full article
(This article belongs to the Section Medical Imaging and Theranostics)
Show Figures

Figure 1

23 pages, 776 KB  
Systematic Review
Performance of Commercial Deep Learning-Based Auto-Segmentation Software for Breast Cancer Radiation Therapy Planning: A Systematic Review
by Curtise K. C. Ng
Multimodal Technol. Interact. 2024, 8(12), 114; https://doi.org/10.3390/mti8120114 - 20 Dec 2024
Cited by 5 | Viewed by 3835
Abstract
As yet, no systematic review on commercial deep learning-based auto-segmentation (DLAS) software for breast cancer radiation therapy (RT) planning has been published, although NRG Oncology has highlighted the necessity for such. The purpose of this systematic review is to investigate the performances of [...] Read more.
As yet, no systematic review on commercial deep learning-based auto-segmentation (DLAS) software for breast cancer radiation therapy (RT) planning has been published, although NRG Oncology has highlighted the necessity for such. The purpose of this systematic review is to investigate the performances of commercial DLAS software packages for breast cancer RT planning and methods for their performance evaluation. A literature search was conducted with the use of electronic databases. Fifteen papers met the selection criteria and were included. The included studies evaluated eight software packages (Limbus Contour, Manteia AccuLearning, Mirada DLCExpert, MVision.ai Contour+, Radformation AutoContour, RaySearch RayStation, Siemens syngo.via RT Image Suite/AI-Rad Companion Organs RT, and Therapanacea Annotate). Their findings show that the DLAS software could contour ten organs at risk (body, contralateral breast, esophagus-overlapping area, heart, ipsilateral humeral head, left and right lungs, liver, and sternum and trachea) and three clinical target volumes (CTVp_breast, CTVp_chestwall, and CTVn_L1) up to the clinically acceptable standard. This can contribute to 45.4%–93.7% contouring time reduction per patient. Although NRO Oncology has suggested that every clinical center should conduct its own DLAS software evaluation before clinical implementation, such testing appears particularly crucial for Manteia AccuLearning, Mirada DLCExpert, and MVision.ai Contour+ as a result of the methodological weaknesses of the corresponding studies such as the use of small datasets collected retrospectively from single centers for the evaluation. Full article
Show Figures

Figure 1

13 pages, 1526 KB  
Article
Can Artificial Intelligence Help Us in the Evaluation of Coronary Artery Calcification Scores by Acting as a Prognosticator in Patients That Are Operated on Due to Non-Small Cell Lung Cancer? A Pivotal Study
by Tomasz Marjanski, Michal Chmielecki, Kaja Klein-Awerjanow, Wojciech Cytawa, Patrycja Ciepialowska, Andrii Bilyk, Rafal Peksa and Magdalena Dudek
J. Clin. Med. 2024, 13(21), 6579; https://doi.org/10.3390/jcm13216579 - 1 Nov 2024
Viewed by 1899
Abstract
Background: Non-small cell lung cancer (NSCLC) is the leading cause of death from malignancies, and surgical resection is the most effective form of treatment. Coronary artery disease (CAD) is a common comorbidity in patients with NSCLC. A coronary artery calcium (CAC) score correlates [...] Read more.
Background: Non-small cell lung cancer (NSCLC) is the leading cause of death from malignancies, and surgical resection is the most effective form of treatment. Coronary artery disease (CAD) is a common comorbidity in patients with NSCLC. A coronary artery calcium (CAC) score correlates with the extent of CAD. We aimed to test whether an automated assessment of CAC scores helps to identify the population of patients with a higher risk of postoperative complications and worse overall survival (OS) after the surgical treatment of NSCLC. Methods: In this retrospective cohort study, the data of the patients who were surgically treated for NSCLC were matched with the reassessed preoperative CT images. The postoperative complication rates and overall survival were analyzed. The CAC score was evaluated automatically using the Syngo.via Siemens Healthcare software. Cardiac age was assessed according to Hoff et al. 2001. The prognosticators of postoperative complications and of OS were tested. Results: The data of 193 patients with complete data, an adherence to the inclusion and exclusion criteria, and that were operated between 2018 and 2019, were included. Cardiac age was a predictor of the cardiovascular and pulmonary complications rate (95%CI −0.007–0.203, p = 0.066, beta coefficient 0.098). In a multivariable stepwise regression analysis, operative access was a predictor of cardiovascular and pulmonary complications (95%CI −0.290–−0.111, p < 0.001, beta coefficient −0.200), cardiovascular complications (95%CI −0.161–−0.022, p = 0.011, beta coefficient −0.036), and the general complication rate (95%CI −0.370–−0.194, p < 0.001, beta coefficient −0.286). Kaplan–Meier curves were separated in the survival analysis of groups of patients with a cardiac age 0–69 years vs. an age of 70+ (92 vs. 92 patients) (in Cox regression analysis, HR = 1.678, 95%CI 0.847–3.292 p = 0.138). Conclusions: An automated CAC score assessment may be a potential and clinically meaningful prognosticator of both postoperative complications and OS in patients that are operated on due to NSCLC. Further studies are required. Full article
(This article belongs to the Special Issue Surgical Treatment for Lung Cancer)
Show Figures

Figure 1

14 pages, 6020 KB  
Article
Assessing the Impact of Long-Term High-Dose Statin Treatment on Pericoronary Inflammation and Plaque Distribution—A Comprehensive Coronary CTA Follow-Up Study
by Botond Barna Mátyás, Imre Benedek, Nóra Raț, Emanuel Blîndu, Zsolt Parajkó, Theofana Mihăilă and Theodora Benedek
Int. J. Mol. Sci. 2024, 25(3), 1700; https://doi.org/10.3390/ijms25031700 - 30 Jan 2024
Cited by 31 | Viewed by 4866
Abstract
Computed tomography angiography (CTA) has validated the use of pericoronary adipose tissue (PCAT) attenuation as a credible indicator of coronary inflammation, playing a crucial role in coronary artery disease (CAD). This study aimed to evaluate the long-term effects of high-dose statins on PCAT [...] Read more.
Computed tomography angiography (CTA) has validated the use of pericoronary adipose tissue (PCAT) attenuation as a credible indicator of coronary inflammation, playing a crucial role in coronary artery disease (CAD). This study aimed to evaluate the long-term effects of high-dose statins on PCAT attenuation at coronary lesion sites and changes in plaque distribution. Our prospective observational study included 52 patients (mean age 60.43) with chest pain, a low-to-intermediate likelihood of CAD, who had documented atheromatous plaque through CTA, performed approximately 1 year and 3 years after inclusion. We utilized the advanced features of the CaRi-Heart® and syngo.via Frontier® systems to assess coronary plaques and changes in PCAT attenuation. The investigation of changes in plaque morphology revealed significant alterations. Notably, in mixed plaques, calcified portions increased (p < 0.0001), while non-calcified plaque volume (NCPV) decreased (p = 0.0209). PCAT attenuation generally decreased after one year and remained low, indicating reduced inflammation in the following arteries: left anterior descending artery (LAD) (p = 0.0142), left circumflex artery (LCX) (p = 0.0513), and right coronary artery (RCA) (p = 0.1249). The CaRi-Heart® risk also decreased significantly (p = 0.0041). Linear regression analysis demonstrated a correlation between increased PCAT attenuation and higher volumes of NCPV (p < 0.0001, r = 0.3032) and lipid-rich plaque volume (p < 0.0001, r = 0.3281). Our study provides evidence that high-dose statin therapy significantly reduces CAD risk factors, inflammation, and plaque vulnerability, as evidenced by the notable decrease in PCAT attenuation, a critical indicator of plaque progression. Full article
Show Figures

Figure 1

12 pages, 1799 KB  
Article
Comparison of Two Contemporary Quantitative Atherosclerotic Plaque Assessment Tools for Coronary Computed Tomography Angiography: Single-Center Analysis and Multi-Center Patient Cohort Validation
by Loris Weichsel, Alexander Giesen, Florian André, Matthias Renker, Stefan Baumann, Philipp Breitbart, Meinrad Beer, Pal Maurovitch-Horvat, Bálint Szilveszter, Borbála Vattay, Sebastian J. Buss, Mohamed Marwan, Andreas A. Giannopoulos, Sebastian Kelle, Norbert Frey and Grigorios Korosoglou
Diagnostics 2024, 14(2), 154; https://doi.org/10.3390/diagnostics14020154 - 9 Jan 2024
Cited by 10 | Viewed by 3576
Abstract
Background: Coronary computed tomography angiography (CCTA) provides non-invasive quantitative assessments of plaque burden and composition. The quantitative assessment of plaque components requires the use of analysis software that provides reproducible semi-automated plaque detection and analysis. However, commercially available plaque analysis software can vary [...] Read more.
Background: Coronary computed tomography angiography (CCTA) provides non-invasive quantitative assessments of plaque burden and composition. The quantitative assessment of plaque components requires the use of analysis software that provides reproducible semi-automated plaque detection and analysis. However, commercially available plaque analysis software can vary widely in the degree of automation, resulting in differences in terms of reproducibility and time spent. Aim: To compare the reproducibility and time spent of two CCTA analysis software tools using different algorithms for the quantitative assessment of coronary plaque volumes and composition in two independent patient cohorts. Methods: The study population included 100 patients from two different cohorts: 50 patients from a single-center (Siemens Healthineers, SOMATOM Force (DSCT)) and another 50 patients from a multi-center study (5 different > 64 slice CT scanner types). Quantitative measurements of total calcified and non-calcified plaque volume of the right coronary artery (RCA), left anterior descending (LAD), and left circumflex coronary artery (LCX) were performed on a total of 300 coronaries by two independent readers, using two different CCTA analysis software tools (Tool #1: Siemens Healthineers, syngo.via Frontier CT Coronary Plaque Analysis and Tool #2: Siemens Healthineers, successor CT Coronary Plaque Analysis prototype). In addition, the total time spent for the analysis was recorded with both programs. Results: The patients in cohorts 1 and 2 were 62.8 ± 10.2 and 70.9 ± 11.7 years old, respectively, 10 (20.0%) and 35 (70.0%) were female and 34 (68.0%) and 20 (40.0%), respectively, had hyperlipidemia. In Cohort #1, the inter- and intra-observer variabilities for the assessment of plaque volumes per patient for Tool #1 versus Tool #2 were 22.8%, 22.0%, and 26.0% versus 2.3%, 3.9%, and 2.5% and 19.7%, 21.4%, and 22.1% versus 0.2%, 0.1%, and 0.3%, respectively, for total, noncalcified, and calcified lesions (p < 0.001 for all between Tools #1 and 2 both for inter- and intra-observer). The inter- and intra-observer variabilities using Tool #2 remained low at 2.9%, 2.7%, and 3.0% and 3.8%, 3.7%, and 4.0%, respectively, for total, non-calcified, and calcified lesions in Cohort #2. For each dataset, the median processing time was higher for Tool #1 versus Tool #2 (459.5 s IQR = 348.0–627.0 versus 208.5 s; IQR = 198.0–216.0) (p < 0.001). Conclusion: The plaque analysis Tool #2 (CT-guided PCI) encompassing a higher degree of automated support required less manual editing, was more time-efficient, and showed a higher intra- and inter-observer reproducibility for the quantitative assessment of plaque volumes both in a representative single-center and in a multi-center validation cohort. Full article
(This article belongs to the Special Issue The Future of Cardiac Imaging in the Diagnosis)
Show Figures

Figure 1

11 pages, 902 KB  
Article
Experimental Examination of Conventional, Semi-Automatic, and Automatic Volumetry Tools for Segmentation of Pulmonary Nodules in a Phantom Study
by Julian Hlouschek, Britta König, Denise Bos, Alina Santiago, Sebastian Zensen, Johannes Haubold, Christoph Pöttgen, Andreas Herz, Marcel Opitz, Axel Wetter, Maja Guberina, Martin Stuschke, Waldemar Zylka, Hilmar Kühl and Nika Guberina
Diagnostics 2024, 14(1), 28; https://doi.org/10.3390/diagnostics14010028 - 22 Dec 2023
Cited by 4 | Viewed by 2154
Abstract
The aim of this study is to examine the precision of semi-automatic, conventional and automatic volumetry tools for pulmonary nodules in chest CT with phantom N1 LUNGMAN. The phantom is a life-size anatomical chest model with pulmonary nodules representing solid and subsolid metastases. [...] Read more.
The aim of this study is to examine the precision of semi-automatic, conventional and automatic volumetry tools for pulmonary nodules in chest CT with phantom N1 LUNGMAN. The phantom is a life-size anatomical chest model with pulmonary nodules representing solid and subsolid metastases. Gross tumor volumes (GTVis) were contoured using various approaches: manually (0); as a means of semi-automated, conventional contouring with (I) adaptive-brush function; (II) flood-fill function; and (III) image-thresholding function. Furthermore, a deep-learning algorithm for automatic contouring was applied (IV). An intermodality comparison of the above-mentioned strategies for contouring GTVis was performed. For the mean GTVref (standard deviation (SD)), the interquartile range (IQR)) was 0.68 mL (0.33; 0.34–1.1). GTV segmentation was distributed as follows: (I) 0.61 mL (0.27; 0.36–0.92); (II) 0.41 mL (0.28; 0.23–0.63); (III) 0.65 mL (0.35; 0.32–0.90); and (IV) 0.61 mL (0.29; 0.33–0.95). GTVref was found to be significantly correlated with GTVis (I) p < 0.001, r = 0.989 (III) p = 0.001, r = 0.916, and (IV) p < 0.001, r = 0.986, but not with (II) p = 0.091, r = 0.595. The Sørensen–Dice indices for the semi-automatic tools were 0.74 (I), 0.57 (II) and 0.71 (III). For the semi-automatic, conventional segmentation tools evaluated, the adaptive-brush function (I) performed closest to the reference standard (0). The automatic deep learning tool (IV) showed high performance for auto-segmentation and was close to the reference standard. For high precision radiation therapy, visual control, and, where necessary, manual correction, are mandatory for all evaluated tools. Full article
(This article belongs to the Special Issue Advances in Cardiovascular and Pulmonary Imaging)
Show Figures

Figure 1

14 pages, 2125 KB  
Article
Potential for Dose Reduction in CT-Derived Left Ventricular Ejection Fraction: A Simulation Study
by Martin Weber Kusk, Søren Hess, Oke Gerke and Shane J. Foley
Tomography 2023, 9(6), 2089-2102; https://doi.org/10.3390/tomography9060164 - 15 Nov 2023
Cited by 3 | Viewed by 3558
Abstract
Background: Measuring left ventricular ejection fraction (LVEF) is important for detecting heart failure, e.g., in treatment with potentially cardiotoxic chemotherapy. MRI is considered the reference standard for LVEF, but availability may be limited and claustrophobia or metal implants still present challenges. CT has [...] Read more.
Background: Measuring left ventricular ejection fraction (LVEF) is important for detecting heart failure, e.g., in treatment with potentially cardiotoxic chemotherapy. MRI is considered the reference standard for LVEF, but availability may be limited and claustrophobia or metal implants still present challenges. CT has been shown to be accurate and would be advantageous, as LVEF could be measured in conjunction with routine chest–abdomen–pelvis oncology CT. However, the use of CT is not recommended due to the excessive radiation dose. This study aimed to explore the potential for dose reduction using simulation. Using an anthropomorphic heart phantom scanned at 13 dose levels, a noise simulation algorithm was developed to introduce controlled Poisson noise. Filtered backprojection parameters were iteratively tested to minimise differences in myocardium-to-ventricle contrast/noise ratio, as well as structural similarity index (SSIM) differences between real and simulated images at all dose levels. Fifty-one clinical CT coronary angiographies, scanned with full dose through end-systolic and -diastolic phases, were located retrospectively. Using the developed algorithm, noise was introduced corresponding to 25, 10, 5 and 2% of the original dose level. LVEF was measured using clinical software (Syngo.via VB50) with papillary muscles in and excluded from the LV volume. At each dose level, LVEF was compared to the 100% dose level, using Bland–Altman analysis. The effective dose was calculated from DLP using a conversion factor of 0.026 mSv/mGycm. Results: In the clinical images, mean CTDIvol and DLP were 47.1 mGy and 771.9 mGycm, respectively (effective dose 20.0 mSv). Measurements with papillary muscles excluded did not exhibit statistically significant LVEF bias to full-dose images at 25, 10 and 5% simulated dose. At 2% dose, a significant bias of 4.4% was found. With papillary muscles included, small but significant biases were found at all simulated dose levels. Conclusion: Provided that measurements are performed with papillary muscles excluded from the LV volume, the dose can be reduced by a factor of 20 without significantly affecting LVEF measurements. This corresponds to an effective dose of 1 mSv. CT can potentially be used for LVEF measurement with minimal excessive radiation. Full article
(This article belongs to the Section Cardiovascular Imaging)
Show Figures

Graphical abstract

11 pages, 1907 KB  
Article
Cardiac MRI: An Alternative Method to Determine the Left Ventricular Function
by Kerstin Michler, Christopher Hessman, Marcus Prümmer, Stephan Achenbach, Michael Uder and Rolf Janka
Diagnostics 2023, 13(8), 1437; https://doi.org/10.3390/diagnostics13081437 - 17 Apr 2023
Cited by 3 | Viewed by 3378
Abstract
(1) Background: With the conventional contour surface method (KfM) for the evaluation of cardiac function parameters, the papillary muscle is considered to be part of the left ventricular volume. This systematic error can be avoided with a relatively easy-to-implement pixel-based evaluation method (PbM). [...] Read more.
(1) Background: With the conventional contour surface method (KfM) for the evaluation of cardiac function parameters, the papillary muscle is considered to be part of the left ventricular volume. This systematic error can be avoided with a relatively easy-to-implement pixel-based evaluation method (PbM). The objective of this thesis is to compare the KfM and the PbM with regard to their difference due to papillary muscle volume exclusion. (2) Material and Methods: In the retrospective study, 191 cardiac-MR image data sets (126 male, 65 female; median age 51 years; age distribution 20–75 years) were analysed. The left ventricular function parameters: end-systolic volume (ESV), end-diastolic volume (EDV), ejection fraction (EF) and stroke volume (SV) were determined using classical KfW (syngo.via and cvi42 = gold standard) and PbM. Papillary muscle volume was calculated and segmented automatically via cvi42. The time required for evaluation with the PbM was collected. (3) Results: The size of EDV was 177 mL (69–444.5 mL) [average, [minimum–maximum]], ESV was 87 mL (20–361.4 mL), SV was 88 mL and EF was 50% (13–80%) in the pixel-based evaluation. The corresponding values with cvi42 were EDV 193 mL (89–476 mL), ESV 101 mL (34–411 mL), SV 90 mL and EF 45% (12–73%) and syngo.via: EDV 188 mL (74–447 mL), ESV 99 mL (29–358 mL), SV 89 mL (27–176 mL) and EF 47% (13–84%). The comparison between the PbM and KfM showed a negative difference for end-diastolic volume, a negative difference for end-systolic volume and a positive difference for ejection fraction. No difference was seen in stroke volume. The mean papillary muscle volume was calculated to be 14.2 mL. The evaluation with PbM took an average of 2:02 min. (4) Conclusion: PbM is easy and fast to perform for the determination of left ventricular cardiac function. It provides comparable results to the established disc/contour area method in terms of stroke volume and measures “true” left ventricular cardiac function while omitting the papillary muscles. This results in an average 6% higher ejection fraction, which can have a significant influence on therapy decisions. Full article
(This article belongs to the Special Issue Advances in Cardiovascular Magnetic Resonance)
Show Figures

Figure 1

11 pages, 2100 KB  
Article
Quantitative Assessment of Lung Volumes and Enhancement in Patients with COVID-19: Role of Dual-Energy CT
by Giovanni Foti, Chiara Longo, Niccolò Faccioli, Massimo Guerriero, Flavio Stefanini and Dora Buonfrate
Diagnostics 2023, 13(6), 1201; https://doi.org/10.3390/diagnostics13061201 - 22 Mar 2023
Cited by 5 | Viewed by 2857
Abstract
Dual-energy computed tomography (DECT) has been used for detecting pulmonary embolism, but the role of lung perfusion DECT as a predictor of prognosis of coronavirus disease 2019 (COVID-19) has not been defined yet. The aim of our study was to explore whether the [...] Read more.
Dual-energy computed tomography (DECT) has been used for detecting pulmonary embolism, but the role of lung perfusion DECT as a predictor of prognosis of coronavirus disease 2019 (COVID-19) has not been defined yet. The aim of our study was to explore whether the enhancement pattern in COVID-19+ patients relates to the disease outcome. A secondary aim was to compare the lung volumes in two subgroups of patients. In this observational study, we considered all consecutive COVID-19+ patients who presented to the emergency room between January 2021 and December 2021 with respiratory symptoms (with mild to absent lung consolidation) and were studied by chest contrast-enhanced DECT to be eligible. Two experienced radiologists post-processed the images using the “lung-analysis” software (SyngoVia). Absolute and relative enhancement lung volumes were assessed. Patients were stratified in two subgroups depending on clinical outcome at 30 days: (i) good outcome (i.e., discharge, absence of clinical or imaging signs of disease); (ii) bad outcome (i.e., hospitalization, death). Patient sub-groups were compared using chi-square test or Fisher test for qualitative parameters, chi-square test or Spearman’s Rho test for quantitative parameters, Students’ t-test for parametric variables and Wilcoxon test for non-parametric variables. We enrolled 78 patients (45M), of whom, 16.7% had good outcomes. We did not observe any significant differences between the two groups, both in terms of the total enhancement evaluation (p = 0.679) and of the relative enhancement (p = 0.918). In contrast, the average lung volume of good outcome patients (mean value of 4262 mL) was significantly larger than that of bad outcome patients (mean value of 3577.8 mL), p = 0.0116. All COVID-19+ patients, with either good or bad outcomes, presented similar enhancement parameters and relative enhancements, underlining no differences in lung perfusion. Conversely, a significant drop in lung volume was identified in the bad outcome subgroup eligible compared to the good outcome subgroup. Full article
(This article belongs to the Special Issue Quantitative Imaging in COVID-19)
Show Figures

Figure 1

Back to TopTop