15 pages, 3574 KiB  
Article
Optimizing Sunflower Husk Pellet Combustion for B2B Bioenergy Commercialization
by Penka Zlateva, Nevena Mileva, Mariana Murzova, Kalin Krumov and Angel Terziev
Energies 2025, 18(15), 4189; https://doi.org/10.3390/en18154189 - 7 Aug 2025
Abstract
This study analyses the potential of using sunflower husks as an energy source by producing bio-pellets and evaluating their combustion process in residential settings. As one of the leading sunflower producers in the European Union, Bulgaria generates significant agricultural residues with high, yet [...] Read more.
This study analyses the potential of using sunflower husks as an energy source by producing bio-pellets and evaluating their combustion process in residential settings. As one of the leading sunflower producers in the European Union, Bulgaria generates significant agricultural residues with high, yet underutilized, energy potential. This study employs a combination of experimental data and numerical modelling aided by ANSYS 2024 R1 to analyse the combustion of sunflower husk pellets in a hot water boiler. The importance of balanced air distribution for achieving optimal combustion, reduced emissions, and enhanced thermal efficiency is emphasized by the results of a comparison of two air supply regimes. It was found that a secondary air-dominated air supply regime results in a more uniform temperature field and a higher degree of oxidation of combustible components. These findings not only confirm the technical feasibility of sunflower husk pellets but also highlight their commercial potential as a sustainable, low-cost energy solution for agricultural enterprises and rural heating providers. The research indicates that there are business-to-business (B2B) market opportunities for biomass producers, boiler manufacturers, and energy distributors who wish to align themselves with EU green energy policies and the growing demand for solutions that support the circular economy. Full article
Show Figures

Figure 1

23 pages, 2593 KiB  
Article
Preliminary Comparison of Ammonia- and Natural Gas-Fueled Micro-Gas Turbine Systems in Heat-Driven CHP for a Small Residential Community
by Mateusz Proniewicz, Karolina Petela, Christine Mounaïm-Rousselle, Mirko R. Bothien, Andrea Gruber, Yong Fan, Minhyeok Lee and Andrzej Szlęk
Energies 2025, 18(15), 4103; https://doi.org/10.3390/en18154103 - 1 Aug 2025
Viewed by 267
Abstract
This research considers a preliminary comparative technical evaluation of two micro-gas turbine (MGT) systems in combined heat and power (CHP) mode (100 kWe), aimed at supplying heat to a residential community of 15 average-sized buildings located in Central Europe over a year. Two [...] Read more.
This research considers a preliminary comparative technical evaluation of two micro-gas turbine (MGT) systems in combined heat and power (CHP) mode (100 kWe), aimed at supplying heat to a residential community of 15 average-sized buildings located in Central Europe over a year. Two systems were modelled in Ebsilon 15 software: a natural gas case (benchmark) and an ammonia-fueled case, both based on the same on-design parameters. Off-design simulations evaluated performance over variable ambient temperatures and loads. Idealized, unrecuperated cycles were adopted to isolate the thermodynamic impact of the fuel switch under complete combustion assumption. Under these assumptions, the study shows that the ammonia system produces more electrical energy and less excess heat, yielding marginally higher electrical efficiency and EUF (26.05% and 77.63%) than the natural gas system (24.59% and 77.55%), highlighting ammonia’s utilization potential in such a context. Future research should target validating ammonia combustion and emission profiles across the turbine load range, and updating the thermodynamic model with a recuperator and SCR accounting for realistic pressure losses. Full article
(This article belongs to the Special Issue Clean and Efficient Use of Energy: 3rd Edition)
Show Figures

Figure 1

20 pages, 11386 KiB  
Article
Real-Time Source Dynamics of PM2.5 During Winter Haze Episodes Resolved by SPAMS: A Case Study in Yinchuan, Northwest China
by Huihui Du, Tantan Tan, Jiaying Pan, Meng Xu, Aidong Liu and Yanpeng Li
Sustainability 2025, 17(14), 6627; https://doi.org/10.3390/su17146627 - 20 Jul 2025
Viewed by 443
Abstract
The occurrence of haze pollution significantly deteriorates air quality and threatens human health, yet persistent knowledge gaps in real-time source apportionment of fine particulate matter (PM2.5) hinder sustained improvements in atmospheric pollution conditions. Thus, this study employed single-particle aerosol mass spectrometry [...] Read more.
The occurrence of haze pollution significantly deteriorates air quality and threatens human health, yet persistent knowledge gaps in real-time source apportionment of fine particulate matter (PM2.5) hinder sustained improvements in atmospheric pollution conditions. Thus, this study employed single-particle aerosol mass spectrometry (SPAMS) to investigate PM2.5 sources and dynamics during winter haze episodes in Yinchuan, Northwest China. Results showed that the average PM2.5 concentration was 57 μg·m−3, peaking at 218 μg·m−3. PM2.5 was dominated by organic carbon (OC, 17.3%), mixed carbonaceous particles (ECOC, 17.0%), and elemental carbon (EC, 14.3%). The primary sources were coal combustion (26.4%), fugitive dust (25.8%), and vehicle emissions (19.1%). Residential coal burning dominated coal emissions (80.9%), highlighting inefficient decentralized heating. Source contributions showed distinct diurnal patterns: coal combustion peaked nocturnally (29.3% at 09:00) due to heating and inversions, fugitive dust rose at night (28.6% at 19:00) from construction and low winds, and vehicle emissions aligned with traffic (17.5% at 07:00). Haze episodes were driven by synergistic increases in local coal (+4.0%), dust (+2.7%), and vehicle (+2.1%) emissions, compounded by regional transport (10.1–36.7%) of aged particles from northwestern zones. Fugitive dust correlated with sulfur dioxide (SO2) and ozone (O3) (p < 0.01), suggesting roles as carriers and reactive interfaces. Findings confirm local emission dominance with spatiotemporal heterogeneity and regional transport influence. SPAMS effectively resolved short-term pollution dynamics, providing critical insights for targeted air quality management in arid regions. Full article
Show Figures

Figure 1

36 pages, 8453 KiB  
Article
Software Supporting the Visualization of Hazardous Substance Emission Zones During a Fire at an Industrial Enterprise
by Yuri Matveev, Fares Abu-Abed, Olga Zhironkina and Sergey Zhironkin
Fire 2025, 8(7), 279; https://doi.org/10.3390/fire8070279 - 14 Jul 2025
Viewed by 498
Abstract
Mathematical modeling and computer visualization of hazardous zones of toxic substance cloud spread that occur during different accidents at industrial enterprises located near residential areas are in high demand to support the operational planning of evacuation measures and accident response. The possible chain-like [...] Read more.
Mathematical modeling and computer visualization of hazardous zones of toxic substance cloud spread that occur during different accidents at industrial enterprises located near residential areas are in high demand to support the operational planning of evacuation measures and accident response. The possible chain-like nature of fires and explosions of containers with toxic substances inside increases the importance of predicting changes in hazardous zone parameters in real time. The objective of this study is to develop algorithms for the development of a mathematical model of a hazardous zone during an explosion and fire at an enterprise. The subject of this study is a software tool created for the visualization of hazardous substance emission zones in real time, superimposed onto a development map to determine potential damage to human health and for the operational planning of evacuation measures. The proposed model takes into account variables such as the air temperature, wind speed and direction, the mass of the substance at each explosion and fire site, etc. C# and Visual Studio 2022 languages and an SQL database were used to create a software tool for visualizing the hazardous area. The testing of the calculation model and software used for the visualization of the hazardous zones of toxic substance cloud spread are presented on the basis of explosion cases involving a railway tank containing ammonia and the combustion of polyvinyl chloride at a chemical industry enterprise. The results confirmed the operability of the software and the prospects of its use in regard to the mitigation of the consequences of human-made accidents. Full article
(This article belongs to the Special Issue Advances in Industrial Fire and Urban Fire Research: 2nd Edition)
Show Figures

Figure 1

13 pages, 1361 KiB  
Article
Characterizing Indoor Black Carbon Dynamics in a Residential Environment: The Role of Human Activity and Ventilation Behavior
by Nikolina Račić, Sanja Frka, Ana Cvitešić Kušan, Valentino Petrić, Francesco Mureddu and Mario Lovrić
Toxics 2025, 13(7), 536; https://doi.org/10.3390/toxics13070536 - 26 Jun 2025
Viewed by 420
Abstract
Understanding indoor black carbon (BC) dynamics is important for assessing human exposure and informing air quality management in residential settings. This study presents a high-resolution, multi-sensor dataset collected over 24 days in a semi-occupied home in Zagreb, Croatia, designed to characterize the temporal [...] Read more.
Understanding indoor black carbon (BC) dynamics is important for assessing human exposure and informing air quality management in residential settings. This study presents a high-resolution, multi-sensor dataset collected over 24 days in a semi-occupied home in Zagreb, Croatia, designed to characterize the temporal behavior and sources of indoor BC. Indoor BC concentrations were measured at 1 min resolution using a dual-spot aethalometer, with source apportionment into biomass burning and fossil fuel components. Complementary contextual data including motion detection, door and window states, and traffic activity were collected in parallel using smart sensors and annotated experimental logs. Across the monitoring period, daily mean BC concentrations ranged from 174.7 and 1053.1 ng/m3 for biomass burning BC and between 53.2 and 880.3 ng/m3 for fossil fuel component. Statistical analyses revealed significant increases in BC concentrations during direct combustion-related activities, including scented candle burning and gas burner use. Additional BC elevations were associated with mechanical heat sources and nearby vehicle traffic, particularly affecting the fossil fuel BC component. In contrast, non-combustion activities such as brief human presence exhibited minor or inconsistent effects on indoor BC levels. This study elucidates the primary role of combustion-based indoor activities in influencing short-term BC exposure and highlights the importance of synchronized, high-resolution datasets for indoor air quality research. Full article
(This article belongs to the Section Air Pollution and Health)
Show Figures

Graphical abstract

15 pages, 1297 KiB  
Article
Thermal and Emission Performance Evaluation of Hydrogen-Enriched Natural Gas-Fired Domestic Condensing Boilers
by Radosław Jankowski, Rafał Ślefarski, Ireneusz Bauma and Giennadii Varlamov
Energies 2025, 18(13), 3240; https://doi.org/10.3390/en18133240 - 20 Jun 2025
Viewed by 355
Abstract
The combustion of gaseous fuels in condensing boilers contributes to the greenhouse gas and toxic compound emissions in exhaust gases. Hydrogen, as a clean energy carrier, could play a key role in decarbonizing the residential heating sector. However, its significantly different combustion behavior [...] Read more.
The combustion of gaseous fuels in condensing boilers contributes to the greenhouse gas and toxic compound emissions in exhaust gases. Hydrogen, as a clean energy carrier, could play a key role in decarbonizing the residential heating sector. However, its significantly different combustion behavior compared to hydrocarbon fuels requires thorough investigation prior to implementation in heating systems. This study presents experimental and theoretical analyses of the co-combustion of natural gas with hydrogen in low-power-output condensing boilers (second and third generation), with hydrogen content of up to 50% by volume. The results show that mixtures of hydrogen and natural gas contribute to increasing heat transfer in boilers through convection and flue gas radiation. They also highlight the benefits of using the heat from the condensation of vapors in the flue gases. Other studies have observed an increase in efficiency of up to 1.6 percentage points compared to natural gas at 50% hydrogen content. Up to a 6% increase in the amount of energy recovered by water vapor condensation was also recorded, while exhaust gas losses did not change significantly. Notably, the addition of hydrogen resulted in a substantial decrease in the emission of nitrogen oxides (NOx) and carbon monoxide (CO). At 50% hydrogen content, NOx emissions decreased several-fold to 2.7 mg/m3, while CO emissions were reduced by a factor of six, reaching 9.9 mg/m3. All measured NOx values remained well below the current regulatory limit for condensing gas boilers, which is 33.5 mg/m3. These results highlight the potential of hydrogen blending as a transitional solution on the path toward cleaner residential heating systems. Full article
(This article belongs to the Special Issue Heat Transfer Analysis: Recent Challenges and Applications)
Show Figures

Figure 1

27 pages, 4289 KiB  
Article
Unveiling Light-Absorbing Carbonaceous Aerosols at a Regional Background Site in Southern Balkans
by Martha Seraskeri, Nestor Kontos, Miltiades I. Michalopoulos, Paraskevi Kardolama, Marina V. Karava, Iliana E. Tasiopoulou, Stylianos K. Garas, Rafaella-Eleni P. Sotiropoulou, Dimitris G. Kaskaoutis and Efthimios Tagaris
Atmosphere 2025, 16(6), 644; https://doi.org/10.3390/atmos16060644 - 26 May 2025
Viewed by 452
Abstract
This study examines the seasonality of Black Carbon (BC) and Brown Carbon (BrC) spectral absorption characteristics at a continental background site (Kozani) in southern Balkans (NW Greece). It aims to assess the seasonality and impact of different sources on light absorption properties, BC [...] Read more.
This study examines the seasonality of Black Carbon (BC) and Brown Carbon (BrC) spectral absorption characteristics at a continental background site (Kozani) in southern Balkans (NW Greece). It aims to assess the seasonality and impact of different sources on light absorption properties, BC concentrations, and the fraction of BrC absorption. Moderate-to-low BC concentrations were observed, ranging from 0.05 µg m−3 to 2.44 µg m−3 on an hourly basis (annual mean: 0.44 ± 0.27 µg m−3; median: 0.39 µg m−3) with higher levels during winter (0.53 ± 0.33), reflecting enhanced emissions from residential wood burning (RWB) for heating purposes. Atmospheric conditions are mostly clean during spring (MAM) (BC: 0.34 µg m−3), associated with increased rainfall. BC components associated with fossil fuel combustion (BCff) and biomass burning (BCbb), maximize in summer (0.36 µg m−3) and winter (0.28 µg m−3), respectively, while the absorption Ångstrôm exponent (AAE370–880) values ranged from 1.09 to 1.93 on daily basis. The annual mean total absorption coefficient (babs,520) inferred by aethalometer (AE33) was 4.09 ± 2.65 Mm−1 (median: 3.51 Mm−1), peaking in winter (5.30 ± 3.35 Mm−1). Furthermore, the contribution of BrC absorption at 370 nm, was also high in winter (36.7%), and lower during the rest of the year (17.3–29.8%). The measuring station is located at a rural background site 4 km outside Kozani City and is not directly affected by traffic and urban heating emissions. Therefore, the regional background atmosphere is composed of a significant fraction of carbonaceous aerosols from RWB in nearby villages, a characteristic feature of the Balkan’s rural environment. Emissions from the lignin-fired power plants, still operating in the region, have decreased during the last years and moderately affect the atmospheric conditions. Full article
Show Figures

Figure 1

16 pages, 4109 KiB  
Article
Spatiotemporal Analysis and Physicochemical Profiling of PM10 and PM2.5 in Slovenia
by Maja Ivanovski, Ivan Anžel, Darko Goričanec and Danijela Urbancl
Atmosphere 2025, 16(5), 540; https://doi.org/10.3390/atmos16050540 - 2 May 2025
Viewed by 529
Abstract
Particulate matter (PM10 and PM2.5) is a key contributor to urban air pollution and poses significant health risks, particularly in densely populated areas. While conventional air quality monitoring focuses on particle size and concentration, this study emphasizes the importance of [...] Read more.
Particulate matter (PM10 and PM2.5) is a key contributor to urban air pollution and poses significant health risks, particularly in densely populated areas. While conventional air quality monitoring focuses on particle size and concentration, this study emphasizes the importance of understanding chemical composition and emission sources for effective air pollution management. PM samples were collected between 2019 and 2022 at two locations in the Republic of Slovenia: a traffic-dominated urban site and an industrial area. Annual average PM10 concentrations ranged from 14 to 34 µg/m3, and those of PM2.5 ranged from 9 to 22 µg/m3. In addition to decreasing annual concentrations, a notable reduction in exceedance days was observed between 2019 and 2022, indicating the effectiveness of recent air quality improvement measures. Meteorological data and statistical models were used to assess environmental influences on PM variability. Advanced SEM-EDS analysis revealed substantial seasonal and spatial differences in particle composition, with key elements such as silicon (4.3–28.4%), carbon (13.1–61.7%), and trace amounts of lead and zinc varying across sites and particle types. Mineral dust (Si, Al, Ca, Fe, Mg), originating from soil resuspension, construction, and Saharan dust, was dominant. Combustion-related particles containing C, Pb, Zn, and Fe oxides were associated with vehicle emissions, industrial processes, and biomass burning. Secondary aerosols, such as sulphates and nitrates, showed seasonal trends, with higher concentrations in summer and winter, respectively. The results confirm that PM levels are driven by complex interactions between local emissions, weather conditions, and seasonal dynamics. The study supports targeted policy measures, particularly regarding residential heating and traffic emissions, to improve air quality. Full article
(This article belongs to the Section Air Quality)
Show Figures

Figure 1

13 pages, 5882 KiB  
Article
Fire and Fire Mitigation by Low-Fuel Building Products
by Kunigal Shivakumar, Bharath Kenchappa and Dhruva Shivakumar
Fire 2025, 8(5), 176; https://doi.org/10.3390/fire8050176 - 30 Apr 2025
Viewed by 464
Abstract
Fire is a combustion reaction where fuel reacts with oxygen in the presence of heat, releasing energy as light, heat, and flames. The main components of fire are fuel, oxygen, and heat. All three components must be present to cause a fire. Fire [...] Read more.
Fire is a combustion reaction where fuel reacts with oxygen in the presence of heat, releasing energy as light, heat, and flames. The main components of fire are fuel, oxygen, and heat. All three components must be present to cause a fire. Fire is a significant threat to residential and commercial buildings, often intensified by high fuel content in building materials such as wood and synthetics. This paper summarizes fire types and damages, loss of property and life, fuel content in building materials, and a method to reduce fire risk by minimizing the building material’s fuel content. This method uses minerals (coal combustion residual (CCR)), primarily inorganic oxides bonded with a small percentage of polyurethane binder, to manufacture a composite material moldable into multiple building products. The composite was tested as per the ASTM for mechanical, thermal, and fire safety performance. ASTM D635-based fire testing showed self-extinguishing behavior with significantly reduced burn rate and lengths (1–2 mm). A low calorific value of 6.6 MJ/kg was determined separately. The test results demonstrate that CCR-based mineral composites offer a fire-resistant, structurally sound, and eco-friendly alternative to wood products. This research supports recycling inorganic minerals into fire-resistant building products that enhance safety. Full article
(This article belongs to the Special Issue Building Fire Dynamics and Fire Evacuation, 2nd Edition)
Show Figures

Figure 1

17 pages, 1660 KiB  
Article
Energy and Environmental Valorisation of Residual Wood Pellet by Small Size Residential Heating Systems
by Valentina Coccia, Ramoon Barros Lovate Temporim, Alessandro Paglianti, Alessia Di Giuseppe, Franco Cotana and Andrea Nicolini
Sustainability 2025, 17(9), 3814; https://doi.org/10.3390/su17093814 - 23 Apr 2025
Viewed by 449
Abstract
Particulate matter (PM) emissions from combustion-based heating systems have been identified as a major contributor to environmental issues and human health risks. Particularly, small-scale residential combustion was responsible for 58% of the total PM2.5 emissions in Europe in 2020, with domestic heating [...] Read more.
Particulate matter (PM) emissions from combustion-based heating systems have been identified as a major contributor to environmental issues and human health risks. Particularly, small-scale residential combustion was responsible for 58% of the total PM2.5 emissions in Europe in 2020, with domestic heating using wood-based fuels accounting for around 56% of soot emissions. Reducing PM2.5 emissions has become a major goal of European environmental policies, which have included it among the key targets of the Zero Pollution Action Plan. In this framework, this study presents a performance analysis of a newly developed PM abatement system consisting of a passive cyclone abatement system (PCAS) specifically designed for small residential pellet stoves. The system was tested under steady-state and non-steady-state operating conditions. The experimental results showed that the PCAS abatement system effectively captured PM at a rate of 10.64 mg/MJ, with great efficiency in capturing particles ≥ 10 µm. The heavy metal content in the captured material was below the limit values for agricultural application-destined soil. A Life Cycle Assessment showed that the PCAS could achieve net-zero PM emissions in 1 year and 8 months. Finally, the economic analysis revealed that the PCAS is significantly more cost-effective: over a 10-year period, it could save up to €4000 in installation, maintenance, and energy costs compared to conventional active systems. These findings highlight the effectiveness of this design of PCAS as in reducing PM emissions from residential heating systems and provide valuable insights for the development of future abatement systems. Full article
(This article belongs to the Section Environmental Sustainability and Applications)
Show Figures

Figure 1

25 pages, 6699 KiB  
Article
Optimization of ORC-Based Micro-CHP Systems: An Experimental and Control-Oriented Study
by Márcio Santos, Jorge André, Ricardo Mendes and José B. Ribeiro
Processes 2025, 13(4), 1104; https://doi.org/10.3390/pr13041104 - 7 Apr 2025
Cited by 1 | Viewed by 916
Abstract
This study presents an experimental and numerical investigation into the performance and control optimization of an Organic Rankine Cycle (ORC)-based micro-combined heat and power (micro-CHP) system. A steady-state, off-design, charge-sensitive model is developed to design a control strategy for an ORC micro-CHP combi-boiler, [...] Read more.
This study presents an experimental and numerical investigation into the performance and control optimization of an Organic Rankine Cycle (ORC)-based micro-combined heat and power (micro-CHP) system. A steady-state, off-design, charge-sensitive model is developed to design a control strategy for an ORC micro-CHP combi-boiler, aiming to efficiently meet real-time domestic hot water demands (up to 40 °C and 35 kW) while generating up to 2 kW of electricity. The system utilizes a natural gas burner to evaporate the working fluid (R245fa), with combustion heat power, volumetric pump speed, and expander speed as control variables. Experimental and numerical evaluations generate steady-state control maps to identify optimal operating regions. A PID-based dynamic control strategy is then developed to stabilize operation during start-ups and user demand variations. The results confirm that the strategy delivers hot water within 1.5 min in simple boiler mode and 3 min in cogeneration mode while improving electricity generation stability and outperforming manual control. The findings demonstrate that integrating steady-state modeling with optimized control enhances the performance, responsiveness, and efficiency of ORC-based micro-CHP systems, making them a viable alternative for residential energy solutions. Full article
(This article belongs to the Special Issue Modeling, Simulation and Control of Industrial Processes)
Show Figures

Figure 1

21 pages, 2536 KiB  
Article
Impact of PM2.5 Exposure from Wood Combustion on Reproductive Health: Implications for Fertility, Ovarian Function, and Fetal Development
by Paulo Salinas, Nikol Ponce, Mariano del Sol and Bélgica Vásquez
Toxics 2025, 13(4), 238; https://doi.org/10.3390/toxics13040238 - 24 Mar 2025
Cited by 1 | Viewed by 917
Abstract
This study evaluates the impact of PM2.5 exposure from wood combustion on reproductive health and fetal development using an experimental model in Sprague Dawley rats. The study was conducted in Temuco, Chile, where high levels of air pollution are primarily attributed to residential [...] Read more.
This study evaluates the impact of PM2.5 exposure from wood combustion on reproductive health and fetal development using an experimental model in Sprague Dawley rats. The study was conducted in Temuco, Chile, where high levels of air pollution are primarily attributed to residential wood burning. A multigenerational exposure model was implemented using controlled exposure chambers with filtered (FA) and unfiltered (NFA) air. Second-generation (G2) female rats (n = 48) were exposed pregestationally (60 days) and gestationally (23 days) under four conditions: FA/FA, FA/NFA, NFA/FA, and NFA/NFA. PM2.5 concentration and composition were monitored using beta-ray attenuation and X-ray fluorescence spectrometry. Reproductive parameters, ovarian follicle counts, and hormonal levels were assessed via vaginal cytology, histological analysis, and chemiluminescence immunoassays. PM2.5 exposure disrupted estrous cyclicity (p = 0.0001), reduced antral and growing follicles (p = 0.0020; p = 0.0317), and increased post-implantation losses (p = 0.0149). Serum progesterone and estradiol levels were significantly altered (p < 0.05). Despite ovarian disruptions, fertility rates remained unchanged. These findings suggest that chronic exposure to wood smoke-derived PM2.5 adversely affects ovarian function and fetal growth without significantly impairing overall reproductive capacity. This study highlights the need for public health policies to mitigate wood smoke pollution. Full article
(This article belongs to the Topic Biomass Use and its Health and Environmental Effects)
Show Figures

Figure 1

14 pages, 503 KiB  
Article
A Risk-Based Approach to Assess the Effectiveness of Sprinklers in Buildings with Combustible Cladding
by Kjetil Pedersen, Kate Nguyen and Ashley Hunt
Fire 2025, 8(4), 119; https://doi.org/10.3390/fire8040119 - 21 Mar 2025
Viewed by 879
Abstract
This study investigates a risk-based approach to evaluate the effectiveness of sprinklers in residential buildings to offset the risk premium imposed by combustible cladding (expanded polystyrene and aluminium composite panels) installed on such buildings in Victoria, Australia. This approach builds upon the Initial [...] Read more.
This study investigates a risk-based approach to evaluate the effectiveness of sprinklers in residential buildings to offset the risk premium imposed by combustible cladding (expanded polystyrene and aluminium composite panels) installed on such buildings in Victoria, Australia. This approach builds upon the Initial Fire Spread in Cladding Assessment Number (IF-SCAN), a concept pioneered by Cladding Safety Victoria as a triage tool in their rectification program. The analysis uses published data from real fires in buildings with and without sprinkler systems installed. It considers three criteria: death rates, injury rates, and construction cost. The construction cost was determined using an existing costing model currently employed in Victoria. The results of this study suggest a higher risk tolerance can be accepted for combustible cladding on buildings equipped with sprinkler systems over that set out in government policy. More specifically, it was found that a building fully protected by sprinklers can generally counterbalance the fire risk posed by combustible cladding spanning up to seven apartments, while a span of up to ten apartments could be considered for buildings without balconies or a private courtyard. Full article
Show Figures

Figure 1

14 pages, 3465 KiB  
Article
Air Pollution Problems in Apartments Equipped with Gas Stoves
by Alexander Shkarovskiy and Agnieszka Maliszewska
Energies 2025, 18(6), 1492; https://doi.org/10.3390/en18061492 - 18 Mar 2025
Cited by 1 | Viewed by 470
Abstract
This article considers issues related to air pollution in residential apartments equipped with gas stoves. The combustion products from gas stoves are released directly into the indoor air, where people can spend a significant part of their time. Even relatively low concentrations of [...] Read more.
This article considers issues related to air pollution in residential apartments equipped with gas stoves. The combustion products from gas stoves are released directly into the indoor air, where people can spend a significant part of their time. Even relatively low concentrations of harmful substances contained in combustion products can pose serious health risks and potentially threaten lives. The detrimental effects of nitrogen oxides (NOx) on human health and the environment are briefly analyzed. A comparison and analysis of legal regulations and standards regarding the maximum permissible concentration of NOx in the air across various countries are conducted. Theoretical calculations estimating the potential NOx levels in gas-equipped kitchens are presented. Additionally, the results of experimental studies measuring the NOx concentrations in the air of apartments with different gas stove designs, burner types, and ventilation methods are presented. The authors’ data are compared with existing data from other similar studies. Full article
(This article belongs to the Special Issue Sustainable Building Energy and Environment: 2nd Edition)
Show Figures

Figure 1

16 pages, 5576 KiB  
Article
Two-Phase Approach for Designing Sustainable Biomass Supply Chains for Community-Scale Biomass Power Plants in Thailand
by Athipthep Boonman, Suneerat Fukuda, Shubham Tiwari and Florian Kraxner
Energies 2025, 18(3), 520; https://doi.org/10.3390/en18030520 - 23 Jan 2025
Viewed by 1294
Abstract
This study proposes a novel two-phase model framework for designing sustainable biomass supply chains of Community-Scale Biomass Power Plants (CSBPPs) by optimization based on geospatial-based Multi-criteria Decision Making (MCDM), the Analytic Hierarchy Process (AHP) method and the Location–Allocation Model. Phase I involved land [...] Read more.
This study proposes a novel two-phase model framework for designing sustainable biomass supply chains of Community-Scale Biomass Power Plants (CSBPPs) by optimization based on geospatial-based Multi-criteria Decision Making (MCDM), the Analytic Hierarchy Process (AHP) method and the Location–Allocation Model. Phase I involved land suitability criteria prioritization and suitable land area analysis. The location–allocation model was the main tool used in Phase II to identify optimal locations, followed by the analysis of the levelized cost of electricity (LCOE). The model optimized site location based on the availability (remaining) of local crop residues, electricity demand, road networks and other key criteria for power plant development, such as the location of substations and the location of existing power plants. The results show that the estimated total remaining crop residue potential in the EEC region was 2403 kt/year, which can generate approximately 34,156 TJ. The location–allocation model identified the top five locations for CSBPPs. The total required installed capacity of these five locations was approximately 100.23 MW in order to serve the district energy demand by the residential sector of 793.82 million (kWh/year). Assuming direct combustion-steam turbine technology with an installed capacity of 6–10 MW, the average LCOE was found to be in a range of $0.076 to $0.081 USD/kWh. Full article
(This article belongs to the Section A4: Bio-Energy)
Show Figures

Figure 1