Sign in to use this feature.

Years

Between: -

Subjects

remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline

Journals

Article Types

Countries / Regions

remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline

Search Results (338)

Search Parameters:
Keywords = photovoltaic seasonality

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
37 pages, 10560 KiB  
Article
Optimizing Building Performance with Dynamic Photovoltaic Shading Systems: A Comparative Analysis of Six Adaptive Designs
by Roshanak Roshan Kharrat, Giuseppe Perfetto, Roberta Ingaramo and Guglielmina Mutani
Smart Cities 2025, 8(4), 127; https://doi.org/10.3390/smartcities8040127 - 3 Aug 2025
Viewed by 240
Abstract
Dynamic and Adaptive solar systems demonstrate a greater potential to enhance the satisfaction of occupants, in terms of indoor environment quality and the energy efficiency of the buildings, than conventional shading solutions. This study has evaluated Dynamic and Adaptive Photovoltaic Shading Systems (DAPVSSs) [...] Read more.
Dynamic and Adaptive solar systems demonstrate a greater potential to enhance the satisfaction of occupants, in terms of indoor environment quality and the energy efficiency of the buildings, than conventional shading solutions. This study has evaluated Dynamic and Adaptive Photovoltaic Shading Systems (DAPVSSs) through a comprehensive analysis of six shading designs in which their energy production and the comfort of occupants were considered. Energy generation, thermal comfort, daylight, and glare control have been assessed in this study, considering multiple orientations throughout the seasons, and a variety of tools, such as Rhino 6.0, Grasshopper, ClimateStudio 2.1, and Ladybug, have been exploited for these purposes. The results showed that the prototypes that were geometrically more complex, designs 5 and 6 in particular, had approximately 485 kWh higher energy production and energy savings for cooling and 48% better glare control than the other simplified configurations while maintaining the minimum daylight as the threshold (min DF: 2%) due to adaptive and control methodologies. Design 6 demonstrated optimal balanced performance for all the aforementioned criteria, achieving 587 kWh/year energy production while maintaining the daylight factor within the 2.1–2.9% optimal range and ensuring visual comfort compliance during 94% of occupied hours. This research has established a framework that can be used to make well-informed design decisions that could balance energy production, occupants’ wellbeing, and architectural integration, while advancing sustainable building envelope technologies. Full article
(This article belongs to the Topic Sustainable Building Development and Promotion)
Show Figures

Figure 1

27 pages, 1948 KiB  
Article
Real-World Performance and Economic Evaluation of a Residential PV Battery Energy Storage System Under Variable Tariffs: A Polish Case Study
by Wojciech Goryl
Energies 2025, 18(15), 4090; https://doi.org/10.3390/en18154090 - 1 Aug 2025
Viewed by 333
Abstract
This paper presents an annual, real-world evaluation of the performance and economics of a residential photovoltaic (PV) system coupled with a battery energy storage system (BESS) in southern Poland. The system, monitored with 5 min resolution, operated under time-of-use (TOU) electricity tariffs. Seasonal [...] Read more.
This paper presents an annual, real-world evaluation of the performance and economics of a residential photovoltaic (PV) system coupled with a battery energy storage system (BESS) in southern Poland. The system, monitored with 5 min resolution, operated under time-of-use (TOU) electricity tariffs. Seasonal variation was significant; self-sufficiency exceeded 90% in summer, while winter conditions increased grid dependency. The hybrid system reduced electricity costs by over EUR 1400 annually, with battery operation optimized for high-tariff periods. Comparative analysis of three configurations—grid-only, PV-only, and PV + BESS—demonstrated the economic advantage of the integrated solution, with the shortest payback period (9.0 years) achieved with financial support. However, grid voltage instability during high PV production led to inverter shutdowns, highlighting limitations in the infrastructure. This study emphasizes the importance of tariff strategies, environmental conditions, and voltage control when designing residential PV-BESS systems. Full article
(This article belongs to the Special Issue Design, Analysis and Operation of Renewable Energy Systems)
Show Figures

Figure 1

20 pages, 5900 KiB  
Article
Experimental Testing and Seasonal Performance Assessment of a Stationary and Sun-Tracked Photovoltaic–Thermal System
by Ewa Kozak-Jagieła, Piotr Cisek, Adam Pawłowski, Jan Taler and Paweł Albrechtowicz
Energies 2025, 18(15), 4064; https://doi.org/10.3390/en18154064 - 31 Jul 2025
Viewed by 307
Abstract
This study presents a comparative analysis of the annual performances of stationary and dual-axis sun-tracked photovoltaic–thermal (PVT) systems. The experimental research was conducted at a demonstration site in Oświęcim, Poland, where both systems were evaluated in terms of electricity and heat production. The [...] Read more.
This study presents a comparative analysis of the annual performances of stationary and dual-axis sun-tracked photovoltaic–thermal (PVT) systems. The experimental research was conducted at a demonstration site in Oświęcim, Poland, where both systems were evaluated in terms of electricity and heat production. The test installation consisted of thirty stationary PVT modules and five dual-axis sun-tracking systems, each equipped with six PV modules. An innovative cooling system was developed for the PVT modules, consisting of a surface-mounted heat sink installed on the rear side of each panel. The system includes embedded tubes through which a cooling fluid circulates, enabling efficient heat recovery. The results indicated that the stationary PVT system outperformed a conventional fixed PV installation, whose expected output was estimated using PVGIS data. Specifically, the stationary PVT system generated 26.1 kWh/m2 more electricity annually, representing a 14.8% increase. The sun-tracked PVT modules yielded even higher gains, producing 42% more electricity than the stationary system, with particularly notable improvements during the autumn and winter seasons. After accounting for the electricity consumed by the tracking mechanisms, the sun-tracked PVT system still delivered a 34% higher net electricity output. Moreover, it enhanced the thermal energy output by 85%. The findings contribute to the ongoing development of high-performance PVT systems and provide valuable insights for their optimal deployment in various climatic conditions, supporting the broader integration of renewable energy technologies in building energy systems. Full article
(This article belongs to the Section A2: Solar Energy and Photovoltaic Systems)
Show Figures

Figure 1

21 pages, 1558 KiB  
Article
Total Performance in Practice: Energy Efficiency in Modern Developer-Built Housing
by Wiktor Sitek, Michał Kosakiewicz, Karolina Krysińska, Magdalena Daria Vaverková and Anna Podlasek
Energies 2025, 18(15), 4003; https://doi.org/10.3390/en18154003 - 28 Jul 2025
Viewed by 233
Abstract
Improving the energy efficiency of residential buildings is essential for achieving global climate goals and reducing environmental impact. This study analyzes the Total Performance approach using the example of a modern semi-detached house built by a Polish developer, as an example. The building [...] Read more.
Improving the energy efficiency of residential buildings is essential for achieving global climate goals and reducing environmental impact. This study analyzes the Total Performance approach using the example of a modern semi-detached house built by a Polish developer, as an example. The building is designed with integrated systems that minimize energy consumption while maintaining resident comfort. The building is equipped with an air-to-water heat pump, underfloor heating, mechanical ventilation with heat recovery, and automatic temperature control systems. Energy efficiency was assessed using ArCADia–TERMOCAD 8.0 software in accordance with Polish Technical Specifications (TS) and verified by monitoring real-time electricity consumption during the heating season. The results show a PED from non-renewable sources of 54.05 kWh/(m2·year), representing a 23% reduction compared to the Polish regulatory limit of 70 kWh/(m2·year). Real-time monitoring conducted from December 2024 to April 2025 confirmed these results, indicating an actual energy demand of approximately 1771 kWh/year. Domestic hot water (DHW) preparation accounted for the largest share of energy consumption. Despite its dependence on grid electricity, the building has the infrastructure to enable future photovoltaic (PV) installation, offering further potential for emissions reduction. The results confirm that Total Performance strategies are not only compliant with applicable standards, but also economically and environmentally viable. They represent a scalable model for sustainable residential construction, in line with the European Union’s (EU’s) decarbonization policy and the goals of the European Green Deal. Full article
(This article belongs to the Section G: Energy and Buildings)
Show Figures

Figure 1

13 pages, 10728 KiB  
Article
Climate Features Affecting the Management of the Madeira River Sustainable Development Reserve, Brazil
by Matheus Gomes Tavares, Sin Chan Chou, Nicole Cristine Laureanti, Priscila da Silva Tavares, Jose Antonio Marengo, Jorge Luís Gomes, Gustavo Sueiro Medeiros and Francis Wagner Correia
Geographies 2025, 5(3), 36; https://doi.org/10.3390/geographies5030036 - 24 Jul 2025
Viewed by 261
Abstract
Sustainable Development Reserves are organized units in the Amazon that are essential for the proper use and sustainable management of the region’s natural resources and for the livelihoods and economy of the local communities. This study aims to provide a climatic characterization of [...] Read more.
Sustainable Development Reserves are organized units in the Amazon that are essential for the proper use and sustainable management of the region’s natural resources and for the livelihoods and economy of the local communities. This study aims to provide a climatic characterization of the Madeira River Sustainable Development Reserve (MSDR), offering scientific support to efforts to assess the feasibility of implementing adaptation measures to increase the resilience of isolated Amazon communities in the face of extreme climate events. Significant statistical analyses based on time series of observational and reanalysis climate data were employed to obtain a detailed diagnosis of local climate variability. The results show that monthly mean two-meter temperatures vary from 26.5 °C in February, the coolest month, to 28 °C in August, the warmest month. Monthly precipitation averages approximately 250 mm during the rainy season, from December until May. July and August are the driest months, August and September are the warmest months, and September and October are the months with the lowest river level. Cold spells were identified in July, and warm spells were identified between July and September, making this period critical for public health. Heavy precipitation events detected by the R80, Rx1day, and Rx5days indices show an increasing trend in frequency and intensity in recent years. The analyses indicated that the MSDR has no potential for wind-energy generation; however, photovoltaic energy production is viable throughout the year. Regarding the two major commercial crops and their resilience to thermal stress, the region presents suitable conditions for açaí palm cultivation, but Brazil nut production may be adversely affected by extreme drought and heat events. The results of this study may support research on adaptation strategies that includethe preservation of local traditions and natural resources to ensure sustainable development. Full article
Show Figures

Figure 1

11 pages, 493 KiB  
Proceeding Paper
PV Power Generation Forecasting with Fuzzy Inference Systems
by Cinthia Rodriguez, Marco Pacheco, Marley Vellasco, Manoela Kohler and Thiago Medeiros
Eng. Proc. 2025, 101(1), 5; https://doi.org/10.3390/engproc2025101005 - 23 Jul 2025
Viewed by 190
Abstract
This paper aims to implement a fuzzy system for the purpose of forecasting the output of photovoltaic (PV) systems. A bibliometric review was conducted to establish a baseline, involving the exploration of six different configuration of fuzzy systems. These systems were trained and [...] Read more.
This paper aims to implement a fuzzy system for the purpose of forecasting the output of photovoltaic (PV) systems. A bibliometric review was conducted to establish a baseline, involving the exploration of six different configuration of fuzzy systems. These systems were trained and evaluated using a sliding window technique and a validation set. The development of the study utilized data collected from 1 May 2018 to 30 June 2018 at the Universidad Autónoma de Occidente campus. The dataset was analyzed in order to identify any discernible trends, seasonal patterns, and instances of stationarity. A comparison of the six models revealed their ability to predict PV power generation, with the model with 13 lags and five fuzzy sets demonstrating results with a reasonable trade-off between training and test performance. The model achieved an R-squared value of 0.8124 and an RMSE of 29.7025 kWh in the test data, indicating that the predictions were closely aligned with the actual values. However, this suggests that the model may be overly simple or may require additional data to more accurately capture the inherent variability of the data. The paper concludes with a discussion of the model’s limitations and potential avenues for future research. Full article
Show Figures

Figure 1

22 pages, 3283 KiB  
Article
Optimal Configuration of Distributed Pumped Storage Capacity with Clean Energy
by Yongjia Wang, Hao Zhong, Xun Li, Wenzhuo Hu and Zhenhui Ouyang
Energies 2025, 18(15), 3896; https://doi.org/10.3390/en18153896 - 22 Jul 2025
Viewed by 232
Abstract
Aiming at the economic problems of industrial users with wind power, photovoltaic, and small hydropower resources in clean energy consumption and trading with superior power grids, this paper proposes a distributed pumped storage capacity optimization configuration method considering clean energy systems. First, considering [...] Read more.
Aiming at the economic problems of industrial users with wind power, photovoltaic, and small hydropower resources in clean energy consumption and trading with superior power grids, this paper proposes a distributed pumped storage capacity optimization configuration method considering clean energy systems. First, considering the maximization of the investment benefit of distributed pumped storage as the upper goal, a configuration scheme of the installed capacity is formulated. Second, under the two-part electricity price mechanism, combined with the basin hydraulic coupling relationship model, the operation strategy optimization of distributed pumped storage power stations and small hydropower stations is carried out with the minimum operation cost of the clean energy system as the lower optimization objective. Finally, the bi-level optimization model is solved by combining the alternating direction multiplier method and CPLEX solver. This study demonstrates that distributed pumped storage implementation enhances seasonal operational performance, improving clean energy utilization while reducing industrial electricity costs. A post-implementation analysis revealed monthly operating cost reductions of 2.36, 1.72, and 2.13 million RMB for wet, dry, and normal periods, respectively. Coordinated dispatch strategies significantly decreased hydropower station water wastage by 82,000, 28,000, and 52,000 cubic meters during corresponding periods, confirming simultaneous economic and resource efficiency improvements. Full article
Show Figures

Figure 1

29 pages, 2431 KiB  
Article
Expectations Versus Reality: Economic Performance of a Building-Integrated Photovoltaic System in the Andean Ecuadorian Context
by Esteban Zalamea-León, Danny Ochoa-Correa, Hernan Sánchez-Castillo, Mateo Astudillo-Flores, Edgar A. Barragán-Escandón and Alfredo Ordoñez-Castro
Buildings 2025, 15(14), 2493; https://doi.org/10.3390/buildings15142493 - 16 Jul 2025
Viewed by 383
Abstract
This article presents an empirical evaluation of the technical and economic performance of a building-integrated photovoltaic (PV) system implemented at the Faculty of Architecture and Urbanism of the University of Cuenca, Ecuador. This study explores both stages of deployment, beginning with a 7.7 [...] Read more.
This article presents an empirical evaluation of the technical and economic performance of a building-integrated photovoltaic (PV) system implemented at the Faculty of Architecture and Urbanism of the University of Cuenca, Ecuador. This study explores both stages of deployment, beginning with a 7.7 kWp pilot system and later scaling to a full 75.6 kWp configuration. This hourly monitoring of power exchanges with utility was conducted over several months using high-resolution instrumentation and cloud-based analytics platforms. A detailed comparison between projected energy output, recorded production, and real energy consumption was carried out, revealing how seasonal variability, cloud cover, and academic schedules influence system behavior. The findings also include a comparison between billed and actual electricity prices, as well as an analysis of the system’s payback period under different cost scenarios, including state-subsidized and real-cost frameworks. The results confirm that energy exports are frequent during weekends and that daily generation often exceeds on-site demand on non-working days. Although the university benefits from low electricity tariffs, the system demonstrates financial feasibility when broader public cost structures are considered. This study highlights operational outcomes under real-use conditions and provides insights for scaling distributed generation in institutional settings, with particular relevance for Andean urban contexts with similar solar profiles and tariff structures. Full article
Show Figures

Figure 1

17 pages, 2518 KiB  
Article
A Methodological Framework for Studying the Tilt Angle of Solar Photovoltaic Panels
by Vitālijs Osadčuks, Dainis Berjoza, Jānis Lāceklis-Bertmanis and Ināra Jurgena
Energies 2025, 18(13), 3487; https://doi.org/10.3390/en18133487 - 2 Jul 2025
Viewed by 484
Abstract
With the development of alternative energy technologies, energy production from renewable sources is gaining wide application. One of the types of renewable energy sources is solar power. In the past 5 years, solar cells have become very popular for both private electricity microgeneration [...] Read more.
With the development of alternative energy technologies, energy production from renewable sources is gaining wide application. One of the types of renewable energy sources is solar power. In the past 5 years, solar cells have become very popular for both private electricity microgeneration and large power plants. There are two main options for installing solar photovoltaic panels: on the roof of a house or the ground; on specially made frames. When installing solar cells on the roof, it is not always possible to choose a tilt angle that is appropriate for all seasons, since the angle is mainly adjusted to the plane of the roof. When installing solar cells on the ground, it is usually possible to choose both the orientation relative to the cardinal points and the tilt angle relative to the ground. There are various theories about the best tilt angle of solar cells for producing the most amount of energy during the year. Therefore, the aim of the present research study is to develop an original research methodology for determining an optimal tilt angle for solar cells. The research study examined six different tilt angles of solar cells, 0°, 30°, 35° 40° 45° and 50°, orienting the cells towards the south. The research study used 18 identical monocrystalline solar panels with a power of 20 W. Three solar panels were set at each angle. This way, the experiment had three replications at each angle of the solar cells. The measurements were recorded by a GWL840 data logger with an interval of 10 s. The experiment was conducted by placing all solar cell modules on the roof of the building at Lat. 56.66181° and Long. 23.75238°. During the experimental period, the highest efficiency was found for the solar panels set at 50° and 40°, reaching the total solar irradiation of 266.61 Wm−2 and 266.27 Wm−2, respectively. Full article
Show Figures

Figure 1

18 pages, 1972 KiB  
Article
Learning from Arctic Microgrids: Cost and Resiliency Projections for Renewable Energy Expansion with Hydrogen and Battery Storage
by Paul Cheng McKinley, Michelle Wilber and Erin Whitney
Sustainability 2025, 17(13), 5996; https://doi.org/10.3390/su17135996 - 30 Jun 2025
Viewed by 500
Abstract
Electricity in rural Alaska is provided by more than 200 standalone microgrid systems powered predominantly by diesel generators. Incorporating renewable energy generation and storage to these systems can reduce their reliance on costly imported fuel and improve sustainability; however, uncertainty remains about optimal [...] Read more.
Electricity in rural Alaska is provided by more than 200 standalone microgrid systems powered predominantly by diesel generators. Incorporating renewable energy generation and storage to these systems can reduce their reliance on costly imported fuel and improve sustainability; however, uncertainty remains about optimal grid architectures to minimize cost, including how and when to incorporate long-duration energy storage. This study implements a novel, multi-pronged approach to assess the techno-economic feasibility of future energy pathways in the community of Kotzebue, which has already successfully deployed solar photovoltaics, wind turbines, and battery storage systems. Using real community load, resource, and generation data, we develop a series of comparison models using the HOMER Pro software tool to evaluate microgrid architectures to meet over 90% of the annual community electricity demand with renewable generation, considering both battery and hydrogen energy storage. We find that near-term planned capacity expansions in the community could enable over 50% renewable generation and reduce the total cost of energy. Additional build-outs to reach 75% renewable generation are shown to be competitive with current costs, but further capacity expansion is not currently economical. We additionally include a cost sensitivity analysis and a storage capacity sizing assessment that suggest hydrogen storage may be economically viable if battery costs increase, but large-scale seasonal storage via hydrogen is currently unlikely to be cost-effective nor practical for the region considered. While these findings are based on data and community priorities in Kotzebue, we expect this approach to be relevant to many communities in the Arctic and Sub-Arctic regions working to improve energy reliability, sustainability, and security. Full article
Show Figures

Figure 1

16 pages, 912 KiB  
Article
Environmental Impact Assessment of Heat Storage System in Rock-Bed Accumulator
by Mateusz Malinowski, Stanisław Bodziacki, Stanisław Famielec, Damian Huptyś, Sławomir Kurpaska, Hubert Latała and Zuzanna Basak
Energies 2025, 18(13), 3360; https://doi.org/10.3390/en18133360 - 26 Jun 2025
Viewed by 243
Abstract
The use of a rock-bed accumulator for a short-term heat storage and air exchange in a building facility is an economical and energy-efficient technological solution to balance and optimize the energy supplied to the facility. Existing scientific studies have not addressed, as yet, [...] Read more.
The use of a rock-bed accumulator for a short-term heat storage and air exchange in a building facility is an economical and energy-efficient technological solution to balance and optimize the energy supplied to the facility. Existing scientific studies have not addressed, as yet, the environmental impacts of using a rock bed for heat storage. The purpose of the research is the environmental life cycle assessment (LCA) of a heat storage system in a rock-bed accumulator supported by a photovoltaic installation. The boundaries of the analyzed system include manufacturing the components of the storage device, land preparation for the construction of the accumulator, the entire construction process, including transportation of materials, and its operation in cooperation with a horticultural facility (foil tunnel) during one growing season, as well as the photovoltaic installation. The functional unit in the analysis is 1 square meter of rock-bed accumulator surface area. SimaPro 8.1 software and Ecoinvent database were used to perform the LCA, applying the ReCiPe model to analyze environmental impact. The analysis showed the largest negative environmental impact occurs during raw materials extraction and component manufacturing (32.38 Pt). The heat stored during one season (April to October) at a greenhouse facility reduces this negative impact by approx. 7%, mainly due to the reduction in the use of fossil fuels to heat the facility. A 3 °C increase in average air temperature results in an average reduction of 0.7% per year in the negative environmental impact of the rock-bed thermal energy storage system. Full article
Show Figures

Figure 1

26 pages, 8296 KiB  
Article
Enhancing Classroom Lighting Quality in Tehran Through the Integration of a Dynamic Light Shelf and Solar Panels
by Shadan Masoud, Zahra Zamani, Seyed Morteza Hosseini, Mohammadjavad Mahdavinejad and Julian Wang
Buildings 2025, 15(13), 2215; https://doi.org/10.3390/buildings15132215 - 24 Jun 2025
Viewed by 525
Abstract
Numerous studies have demonstrated that appropriate use of daylight in educational spaces significantly enhances students’ health and academic performance. However, classrooms in Tehran still suffer from considerable daylighting challenges. In many cases, desks near windows are exposed to excessive brightness, while areas farther [...] Read more.
Numerous studies have demonstrated that appropriate use of daylight in educational spaces significantly enhances students’ health and academic performance. However, classrooms in Tehran still suffer from considerable daylighting challenges. In many cases, desks near windows are exposed to excessive brightness, while areas farther from the windows lack adequate illumination. This often leads to the use of curtains and artificial lighting, resulting in higher energy consumption and potential negative impacts on student learning. Light shelf systems have been proposed as effective daylighting solutions to improve light penetration and distribution. According to previous research, three key parameters—geometry, depth, and surface reflectance—play a critical role in the performance of light shelves. However, prior studies have typically focused on improving one or two of these parameters in isolation. There is a lack of research evaluating all three parameters simultaneously to determine season-specific configurations for optimal performance. Addressing this gap, the present study investigates the combined effects of light shelf geometry, depth, and reflectance across different seasons and proposes a system that dynamically adapts these parameters throughout the year. In winter, the system also integrates photovoltaic panels to reduce glare and generate electricity for its operation. Simulation results indicate that the proposed system leads to a 21% improvement in Useful Daylight Illuminance (UDI), a 65% increase in thermal comfort, and a 10% annual reduction in energy consumption. These findings highlight the potential of the proposed system as a practical and energy-efficient daylighting strategy for educational buildings in sunny regions such as Tehran. Full article
Show Figures

Figure 1

17 pages, 2158 KiB  
Article
Study on the Impact of Large-Scale Photovoltaic Systems on Key Surface Parameters in Desert Area Regions of Xinjiang, China
by Junxia Jiang, Huan Du, Huihui Yin and Hongbo Su
Energies 2025, 18(12), 3170; https://doi.org/10.3390/en18123170 - 17 Jun 2025
Viewed by 362
Abstract
This study evaluated the effects of photovoltaic (PV) arrays on critical surface parameters through analysis of observational data collected from a utility-scale PV power station located in Wujiaqu City, Xinjiang, in 2021. The results reveal that: (1) Installation of PV panels reduces surface [...] Read more.
This study evaluated the effects of photovoltaic (PV) arrays on critical surface parameters through analysis of observational data collected from a utility-scale PV power station located in Wujiaqu City, Xinjiang, in 2021. The results reveal that: (1) Installation of PV panels reduces surface albedo, which is significantly altered by dust storm conditions; (2) the installation of PV arrays increases the aerodynamic and thermal roughness length by increasing the frictional velocity across the mixed underlying surface; (3) the overall transport coefficients within the PV plant are higher than that of the reference site, with greater diurnal variation than nocturnal variation. The overall transport coefficient is highest in the unstable stratification conditions and lowest under stable stratification conditions; and (4) soil thermal property parameters exhibit seasonal variations. Significant changes in thermal conductivity and specific heat capacity were observed during spring thaw, high and fluctuating diffusivity in summer, and low and stable values in winter. The findings demonstrate that installing PV arrays in arid regions modifies surface energy balance and heat transfer characteristics. This provides a basis for optimizing PV station layouts and conducting climate impact assessments. Full article
(This article belongs to the Section A2: Solar Energy and Photovoltaic Systems)
Show Figures

Figure 1

35 pages, 7539 KiB  
Article
Tomato Yield Under Different Shading Levels in an Agrivoltaic Greenhouse in Southern Spain
by Anna Kujawa, Julian Kornas, Natalie Hanrieder, Sergio González Rodríguez, Lyubomir Hristov, Álvaro Fernández Solas, Stefan Wilbert, Manuel Jesus Blanco, Leontina Berzosa Álvarez, Ana Martínez Gallardo, Adoración Amate González, Marina Casas Fernandez, Francisco Javier Palmero Luque, Manuel López Godoy, María del Carmen Alonso-García, José Antonio Carballo, Luis Fernando Zarzalejo Tirado, Cristina Cornaro and Robert Pitz-Paal
AgriEngineering 2025, 7(6), 178; https://doi.org/10.3390/agriengineering7060178 - 6 Jun 2025
Cited by 1 | Viewed by 2324
Abstract
Agrivoltaic greenhouses in southern Spain offer a sustainable way to manage excessive irradiance levels by generating renewable energy. This study presents a shading experiment on tomato cultivation in a raspa-y-amagado greenhouse in Almeria, southern Spain, during the 2023–2024 growing season. Photovoltaic modules were [...] Read more.
Agrivoltaic greenhouses in southern Spain offer a sustainable way to manage excessive irradiance levels by generating renewable energy. This study presents a shading experiment on tomato cultivation in a raspa-y-amagado greenhouse in Almeria, southern Spain, during the 2023–2024 growing season. Photovoltaic modules were mimicked by opaque plastic sheets that were arranged in a checkerboard pattern on the roof of the greenhouse. Two shading zones (30% and 50% roof cover ratio) were compared against an unshaded control zone. Microclimate, plant physiology, yield and quality were monitored during the study. The results show that shading influenced the microclimate, which directly impacted crop yield. The 30% and 50% shading zones resulted in 15% and 26% crop yield reductions, respectively. A preliminary, theoretical analysis of potential revenues of the photovoltaic yield showed that reductions in crop yield can be overcompensated by the energy generated by the PV system. For the summer crop cycle, a higher PV production and lower crop yield reductions can be expected. The economic advantage demonstrates the potential of agrivoltaic greenhouses in southern Spain. Full article
Show Figures

Figure 1

28 pages, 3215 KiB  
Article
Optimization of Solar Generation and Battery Storage for Electric Vehicle Charging with Demand-Side Management Strategies
by César Berna-Escriche, Lucas Álvarez-Piñeiro and David Blanco
World Electr. Veh. J. 2025, 16(6), 312; https://doi.org/10.3390/wevj16060312 - 3 Jun 2025
Viewed by 860
Abstract
The integration of Electric Vehicles (EVs) with solar power generation is important for decarbonizing the economy. While electrifying transportation reduces Greenhouse Gas (GHG) emissions, its success depends on ensuring that EVs are charged with clean energy, requiring significant increases in photovoltaic capacity and [...] Read more.
The integration of Electric Vehicles (EVs) with solar power generation is important for decarbonizing the economy. While electrifying transportation reduces Greenhouse Gas (GHG) emissions, its success depends on ensuring that EVs are charged with clean energy, requiring significant increases in photovoltaic capacity and robust Demand-Side Management (DSM) solutions. EV charging patterns, such as home, workplace, and public charging, need adapted strategies to match solar generation. This study analyzes a system designed to meet a unitary hourly average energy demand (8760 MWh annually) using an optimization framework that balances PV capacity and battery storage to ensure reliable energy supply. Historical solar data from 22 years is used to analyze seasonal and interannual fluctuations. The results show that solar PV alone can cover around 30% of the demand without DSM, rising to nearly 50% with aggressive DSM measures, using PV capacities of 1.0–2.0 MW. The optimization reveals that incorporating battery storage can achieve near 100% coverage with PV power of 8.0–9.0 MW. Moreover, DSM reduces required storage from 18 to about 10 MWh. These findings highlight the importance of integrating optimization-based energy management strategies to enhance system efficiency and cost-effectiveness, offering a pathway toward a more sustainable and resilient EV charging infrastructure. Full article
Show Figures

Figure 1

Back to TopTop