Sign in to use this feature.

Years

Between: -

Subjects

remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline

Journals

Article Types

Countries / Regions

Search Results (11)

Search Parameters:
Keywords = peak capacitor voltage reduction

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
29 pages, 2719 KB  
Article
Risk-Averse Coordinated Operation of Rural Multi-Energy Microgrids Considering Voltage Quality Control
by Jiangdong Liu, Jun Han, Jiajing Liu, Wenshu Ding, Liang Feng and Yuqing Qu
Energies 2026, 19(13), 3107; https://doi.org/10.3390/en19133107 - 30 Jun 2026
Viewed by 221
Abstract
Rural distribution networks increasingly face voltage quality challenges due to high penetration of distributed renewable energy, heterogeneous rural load behavior, and long radial feeder structures with limited voltage regulation capability. Photovoltaic generation variability and agricultural load fluctuations can lead to voltage rise, reverse [...] Read more.
Rural distribution networks increasingly face voltage quality challenges due to high penetration of distributed renewable energy, heterogeneous rural load behavior, and long radial feeder structures with limited voltage regulation capability. Photovoltaic generation variability and agricultural load fluctuations can lead to voltage rise, reverse power flow, and branch congestion, particularly in weak rural grids. Conventional deterministic voltage control approaches relying on tap changers and capacitor banks often struggle to maintain stable voltage profiles under stochastic operating conditions. This paper proposes a risk-aware coordinated operation framework for rural multi-energy microgrids that integrates stochastic scenario modeling, voltage state perception, and adaptive optimization-based control. Renewable generation uncertainty and rural load variability are represented through correlated scenario generation and Wasserstein-distance-based scenario reduction, where 100 raw joint photovoltaic-load trajectories are reduced to 20 representative scenarios after convergence and distributional-fidelity tests. A stochastic optimization model is developed to coordinate photovoltaic inverters, battery energy storage systems, demand-side flexibility, and reactive compensation devices while satisfying network power-flow, voltage-security, storage, and communication-delay-aware implementation constraints. To mitigate extreme voltage deviation events, the framework incorporates a Conditional Value-at-Risk formulation that penalizes tail-risk voltage violations and maintains voltages within a preferred operating band of 0.971.03 p.u. Case studies on a modified IEEE 33-bus rural distribution system with 2.00 MW of photovoltaic capacity and 2.50 MWh of battery storage demonstrate consistent performance improvements across deterministic, risk-neutral stochastic, chance-constrained, and robust baselines. The proposed strategy reduces peak branch loading from 0.95 in the deterministic benchmark to 0.72, while the 95th percentile voltage deviation risk decreases from 0.0071 p.u.2 to 0.0020 p.u.2. Sensitivity, scenario-convergence, scalability, and seasonal representative-day analyses further confirm that the CVaR layer suppresses rare but severe voltage excursions without imposing excessive curtailment or computational burden. Full article
Show Figures

Figure 1

31 pages, 2206 KB  
Article
Coordinated Allocation of Multi-Type DERs and EVCSs in Distribution Networks Using a Multi-Stage GSA Framework
by Arindam Roy and Vimlesh Verma
Mathematics 2026, 14(5), 894; https://doi.org/10.3390/math14050894 - 6 Mar 2026
Viewed by 483
Abstract
This study introduces a multi-stage, multi-objective optimization framework based on the Gravitational Search Algorithm (GSA) for determining the optimal sizing and placement of distributed energy resources (DERs) and associated infrastructure. The proposed approach considers solar distributed generation (DG) units with battery storage systems [...] Read more.
This study introduces a multi-stage, multi-objective optimization framework based on the Gravitational Search Algorithm (GSA) for determining the optimal sizing and placement of distributed energy resources (DERs) and associated infrastructure. The proposed approach considers solar distributed generation (DG) units with battery storage systems (BSSs), wind DGs, shunt capacitors (SCs) and electric vehicle charging stations (EVCSs). With the rapid adoption of electric vehicles as part of global decarbonization efforts, integrating EVCSs into already stressed distribution networks poses significant operational challenges, often requiring system reinforcement supported by renewable-based DGs. The uncoordinated deployment of EVCSs and DGs can exacerbate power losses and deteriorate voltage profiles. To address these issues, the first stage of the methodology employs GSA to optimally allocate solar DGs with BSSs, wind DGs and SCs, targeting objectives such as minimizing power losses, enhancing voltage stability and alleviating substation loading. The second stage identifies optimal locations and maximum feasible capacities for EVCS integration. Finally, the third stage upgrades the network to mitigate the impacts of EVCS integration. The effectiveness of the proposed approach is validated through simulations on a practical 52-bus, 11 kV distribution network under hourly varying load, solar irradiance and wind velocity conditions for all seasons. The simulation results show an 85% reduction in power losses during peak hours, with nodal voltages maintained above 0.95 p.u. under all scenarios. Additionally, net-zero grid power exchange during peak periods confirms the full islanded operation. Full article
(This article belongs to the Special Issue Advances of Optimization Theory and Applications)
Show Figures

Figure 1

21 pages, 386 KB  
Article
Techno-Economic Assessment of Fixed and Variable Reactive Power Injection Using Thyristor-Switched Capacitors in Distribution Networks
by Oscar Danilo Montoya, César Leonardo Trujillo-Rodríguez and Carlos Andrés Torres-Pinzón
Electricity 2025, 6(3), 46; https://doi.org/10.3390/electricity6030046 - 11 Aug 2025
Cited by 3 | Viewed by 1409
Abstract
This paper presents a hybrid optimization framework for solving the optimal reactive power compensation problem in medium-voltage smart distribution networks. Leveraging Julia’s computational environment, the proposed method combines the global search capabilities of the Chu & Beasley genetic algorithm (CBGA) with the local [...] Read more.
This paper presents a hybrid optimization framework for solving the optimal reactive power compensation problem in medium-voltage smart distribution networks. Leveraging Julia’s computational environment, the proposed method combines the global search capabilities of the Chu & Beasley genetic algorithm (CBGA) with the local refinement efficiency of the interior-point optimizer (IPOPT). The objective is to minimize the annualized operating costs by reducing active power losses while considering the investment and operating costs associated with thyristor-switched capacitors (TSCs). A key contribution of this work is the comparative assessment of fixed and time-varying reactive power injection strategies. Simulation results on the IEEE 33- and 69-bus test feeders demonstrate that the proposed CBGA-IPOPT framework achieves annualized cost reductions of up to 11.22% and 12.58% (respectively) under fixed injection conditions. With variable injection, cost savings increase to 12.43% and 14.08%. A time-domain analysis confirms improved voltage regulation, substation reactive demand reductions exceeding 500 kvar, and peak loss reductions of up to 32% compared to the uncompensated case. Benchmarking shows that the hybrid framework not only consistently outperforms state-of-the-art metaheuristics (the sine-cosine algorithm, the particle swarm optimizer, the black widow optimizer, and the artificial hummingbird algorithm) in terms of solution quality but also demonstrates high solution repeatability across multiple runs, underscoring its robustness. The proposed method is directly applicable to real-world distribution systems, offering a scalable and cost-effective solution for reactive power planning in smart grids. Full article
Show Figures

Figure 1

29 pages, 8083 KB  
Article
DC-Link Voltage Stabilization and Capacitor Size Reduction in Active Neutral-Point-Clamped Inverters Using an Advanced Control Method
by Ahmet Yuksel, Ibrahim Sefa and Necmi Altin
Energies 2025, 18(12), 3143; https://doi.org/10.3390/en18123143 - 15 Jun 2025
Cited by 6 | Viewed by 3041
Abstract
This study examines the impact of midpoint voltage fluctuations on the performance of multilevel converters and proposes an advanced control strategy to reduce the required DC bus capacitance while maintaining system stability. The research demonstrates that active voltage imbalance control in active neutral-point-clamped [...] Read more.
This study examines the impact of midpoint voltage fluctuations on the performance of multilevel converters and proposes an advanced control strategy to reduce the required DC bus capacitance while maintaining system stability. The research demonstrates that active voltage imbalance control in active neutral-point-clamped (ANPC) topologies allows for stable operation with significantly reduced capacitor values. A hybrid control approach, combining fuzzy logic control and third-harmonic injection PWM (THIPWM), is developed to enhance voltage balancing, and modulation techniques are systematically optimized. Both simulation and experimental analyses confirm the efficacy of the proposed method, which achieves superior voltage regulation compared to conventional PI-based control schemes. Specifically, experimental results show a reduction in peak-to-peak DC-link voltage fluctuation from 116 V to just 4 V, and the phase current THD is reduced from 3.6% to 0.8%. The results indicate a substantial reduction in voltage fluctuations, contributing to a total harmonic distortion (THD) as low as 0.8%. Furthermore, the proposed strategy facilitates an approximate 26-fold decrease in DC bus capacitor size without compromising system stability. The reduction in capacitance not only lowers the overall system costs and hardware complexity but also improves reliability. The inverter was tested at a rated power of 62.5 kW using 0.3 mF capacitors instead of the theoretically required 7.8 mF. This work advances power electronics by presenting an efficient voltage balancing methodology, offering a cost-effective and robust solution for multilevel converter applications. The findings are validated through comprehensive simulations and experimental tests, ensuring practical applicability. Full article
Show Figures

Figure 1

14 pages, 7854 KB  
Article
Adaptive DC-Link Voltage Control for 22 kW, 40 kHz LLC Resonant Converter Considering Low-Frequency Voltage Ripple
by Roland Unruh, Joachim Böcker and Frank Schafmeister
Electronics 2025, 14(8), 1517; https://doi.org/10.3390/electronics14081517 - 9 Apr 2025
Cited by 4 | Viewed by 2477
Abstract
The LLC converter achieves the highest efficiency in resonant operation. Conventionally, the input DC-link voltage is controlled to operate the LLC converter at resonance for the given operating point. However, the DC-link capacitor voltage shows a low-frequency voltage ripple (typically the second harmonic [...] Read more.
The LLC converter achieves the highest efficiency in resonant operation. Conventionally, the input DC-link voltage is controlled to operate the LLC converter at resonance for the given operating point. However, the DC-link capacitor voltage shows a low-frequency voltage ripple (typically the second harmonic of grid frequency) in cascaded converters so that the LLC has to adapt its switching frequency within the grid period. Conventionally, the LLC converter operates 50% of the time above the resonant frequency of 40 kHz and 50% below resonance. Both operating conditions cause additional losses. However, experimental measurements indicate that the below-resonance operation causes significantly higher losses than above-resonance operation due to much higher primary and secondary transformer currents. It is better to increase the DC-link voltage by 30% of the peak-to-peak low-frequency voltage ripple to mostly avoid below-resonance operation (i.e., from 650 V to 680 V in this case). With the proposed control, the LLC converter operates about 75% of time over resonance and only 25% of time below resonance. The overall efficiency increases from 97.66% to 97.7% for the average operating point with an 80% load current. This corresponds to a 2% total loss reduction. Finally, the peak resonance capacitor voltage decreases from 910 V to 790 V (−13%). Full article
(This article belongs to the Special Issue Innovative Technologies in Power Converters, 2nd Edition)
Show Figures

Figure 1

19 pages, 1163 KB  
Article
A Modified Nearest Level Control Scheme for Improved Submodule Current Sharing in a CHB Converter with Integrated EDLCs
by Viktor Döhlen and Kent Bertilsson
Energies 2025, 18(7), 1697; https://doi.org/10.3390/en18071697 - 28 Mar 2025
Viewed by 941
Abstract
This study investigates a Cascaded H-Bridge converter with Electric Double-Layer Capacitors as integrated energy storage components. As the DC-link voltages are variable, the modulation index and number of submodules contributing to the active power delivery vary according to state of charge. The nearest [...] Read more.
This study investigates a Cascaded H-Bridge converter with Electric Double-Layer Capacitors as integrated energy storage components. As the DC-link voltages are variable, the modulation index and number of submodules contributing to the active power delivery vary according to state of charge. The nearest level control algorithm for this application is studied, and expressions for the duty cycle of conventional Nearest Level Modulation are derived. A modification of the sort and select algorithm to determine which submodule is to be inserted and bypassed when using the Nearest Level Control algorithm is proposed to distribute the activation time and the experienced RMS current of the submodules. Expressions for the duty cycle of each inserted submodule for the proposed algorithm is presented and compared to the conventional. Simulation experiments of current sharing between submodules under active power delivery for the conventional and proposed Nearest Level Control is conducted for an 11- level, 41-level and 61-level converter. Simulation experiments show a reduction in RMS current for the submodule experiencing the highest thermal stress. Over the course of power delivery and increasing modulation index, the peak RMS current increase for the conventional nearest level modulation while it is kept constant for the proposed modulation scheme. Full article
(This article belongs to the Special Issue Advances in Design and Control of Power Electronic Systems)
Show Figures

Figure 1

13 pages, 5267 KB  
Article
Design, Fabrication, and Characterization of a Planar Three-Electrode Trigger Switch Based on Flexible Printed Circuit Process
by Pengfei Xue, Peng Xiong, Heng Hu, Tao Wang, Mingyu Li and Qingxuan Zeng
Micromachines 2024, 15(5), 586; https://doi.org/10.3390/mi15050586 - 28 Apr 2024
Cited by 2 | Viewed by 3483
Abstract
An exploding foil initiator system (EFIs) is essential in modern weaponry for its safety and reliability. As the main component of EFIs, the performance of the switch is critical to EFIs. In this study, a planar three-electrode trigger switch was designed and fabricated [...] Read more.
An exploding foil initiator system (EFIs) is essential in modern weaponry for its safety and reliability. As the main component of EFIs, the performance of the switch is critical to EFIs. In this study, a planar three-electrode trigger switch was designed and fabricated using the Flexible Printed Circuits (FPC) process. Subsequently, the performance of the FPC switch was tested. The results show that the self-breakdown voltage of the FPC switch is stable. In addition, an FPF switch with a 0.6 mm main electrode gap demonstrated consistency, with delay times below 31.75 ns, and a jitter ranging from 1.7 ns to 10.94 ns at 900 V to 1200 V, evidencing the FPC switches’ reliability and uniform performance across various voltages. Compared to the Micro-Electro-Mechanical Systems (MEMS) switches of similar dimensions, the FPC switches achieved a faster high-current attainment with less inductance, showing a 5% reduction in loop inductance. The repetitive testing results demonstrate that the FPC switch maintains consistent output performance, with stable peak currents, peak current time, and delay time over 50 action cycles, highlighting its repeatability. The FPC switch was assembled with an EFI chip and capacitor into an integrated system, which was subsequently able to successfully detonate HNS-IV at 1000 V/0.22 μF, proving the FPC switch’s potential in low inductance applications. Full article
(This article belongs to the Section E:Engineering and Technology)
Show Figures

Figure 1

24 pages, 4366 KB  
Article
Optimal Integration of Capacitor and Distributed Generation in Distribution System Considering Load Variation Using Bat Optimization Algorithm
by Thangaraj Yuvaraj, Kaliaperumal Rukmani Devabalaji, Natarajan Prabaharan, Hassan Haes Alhelou, Asokkumar Manju, Poushali Pal and Pierluigi Siano
Energies 2021, 14(12), 3548; https://doi.org/10.3390/en14123548 - 15 Jun 2021
Cited by 50 | Viewed by 4097
Abstract
In this article, an efficient long-term novel scheduling technique is proposed for allocating capacitors in a combined system involving distributed generation (DG) along with radial distribution systems (RDS). We introduce a unique multi-objective function that focuses on the reduction of power loss with [...] Read more.
In this article, an efficient long-term novel scheduling technique is proposed for allocating capacitors in a combined system involving distributed generation (DG) along with radial distribution systems (RDS). We introduce a unique multi-objective function that focuses on the reduction of power loss with the maximization of voltage stability index (VSI) subjected to constraints of equality and inequality systems. Loss sensitivity factor and VSI together are involved in pre-identifying the locations of capacitors and DG. Determination of the optimal size of capacitor and DG is performed by utilizing the Bat algorithm (BA) for all the loads in RDS. The conventional approach considers the medium load of (1.0) condition generally, but the proposed method changes the feeder loads linearly, ranging from light load (0.5) to peak load (1.6) with the value of step size as 1%. BA determines the optimal size of the capacitor and DG for each step load. The curve fitting technique is used for deducing the generalized equation of capacitor size and DG for all conditions of the load with the various loading condition sized by distributed network operators (DNOs). Further, various load models such as industrial, residential, and commercial loads have been considered to show the efficiency of the present approach. Validation of results is performed in different scenarios on a 69-bus test system and on a standard IEEE 33-bus system. The results exhibit improved accuracy with less power loss value, superior bus voltage, and stability of system voltage with a higher rate of convergence. Full article
Show Figures

Figure 1

16 pages, 4610 KB  
Article
SEPIC Converter with an LC Regenerative Snubber for EV Applications
by Abdalkreem Kasasbeh, Burak Kelleci, Salih Baris Ozturk, Ahmet Aksoz and Omar Hegazy
Energies 2020, 13(21), 5765; https://doi.org/10.3390/en13215765 - 3 Nov 2020
Cited by 11 | Viewed by 5726
Abstract
A Single-Ended Primary-Inductor Converter (SEPIC) converter with an Inductor-Capacitor (LC) regenerative snubber is proposed to reduce Electromagnetic Interference (EMI) for Electric Vehicle (EV) applications. The switching energy is transferred through a capacitor to an inductor which is coupled to SEPIC inductors. This technique [...] Read more.
A Single-Ended Primary-Inductor Converter (SEPIC) converter with an Inductor-Capacitor (LC) regenerative snubber is proposed to reduce Electromagnetic Interference (EMI) for Electric Vehicle (EV) applications. The switching energy is transferred through a capacitor to an inductor which is coupled to SEPIC inductors. This technique reduces the number of components and also returns some of switching energy to SEPIC converter. The mathematical analysis and optimization of LC snubber with respect to number of turns is also presented. Spice simulations and experimental results are provided to verify its performance. The proposed LC regenerative snubber reduces the peak voltage by 16 V on the switching transistor during the switching transient. It is also indicated that 8 dB reduction is achieved in the EMI measurements at ringing frequency and 10 dB reduction at high frequency band. Full article
Show Figures

Figure 1

28 pages, 11049 KB  
Article
A New Robust Energy Management and Control Strategy for a Hybrid Microgrid System Based on Green Energy
by Bilal Naji Alhasnawi, Basil H. Jasim and M. Dolores Esteban
Sustainability 2020, 12(14), 5724; https://doi.org/10.3390/su12145724 - 16 Jul 2020
Cited by 50 | Viewed by 5957
Abstract
The recent few years have seen renewable energy becoming immensely popular. Renewable energy generation capacity has risen in both standalone and grid-connected systems. The chief reason is the ability to produce clean energy, which is both environmentally friendly and cost effective. This paper [...] Read more.
The recent few years have seen renewable energy becoming immensely popular. Renewable energy generation capacity has risen in both standalone and grid-connected systems. The chief reason is the ability to produce clean energy, which is both environmentally friendly and cost effective. This paper presents a new control algorithm along with a flexible energy management system to minimize the cost of operating a hybrid microgrid. The microgrid comprises fuel cells, photovoltaic cells, super capacitors, and other energy storage systems. There are three stages in the control system: an energy management system, supervisory control, and local control. The energy management system allows the control system to create an optimal day-ahead power flow schedule between the hybrid microgrid components, loads, batteries, and the electrical grid by using inputs from economic analysis. The discrepancy between the scheduled power and the real power delivered by the hybrid microgrid is adjusted for by the supervisory control stage. Additionally, this paper provides a design for the local control system to manage local power, DC voltage, and current in the hybrid microgrid. The operation strategy of energy storage systems is proposed to solve the power changes from photovoltaics and houses load fluctuations locally, instead of reflecting those disturbances to the utility grid. Furthermore, the energy storage systems energy management scheme will help to achieve the peak reduction of the houses’ daily electrical load demand. Also, the control of the studied hybrid microgrid is designed as a method to improve hybrid microgrid resilience and incorporate renewable power generation and storage into the grid. The simulation results verified the effectiveness and feasibility of the introduced strategy and the capability of proposed controller for a hybrid microgrid operating in different modes. The results showed that (1) energy management and energy interchange were effective and contributed to cost reductions, CO2 mitigation, and reduction of primary energy consumption, and (2) the newly developed energy management system proved to provide more robust and high performance control than conventional energy management systems. Also, the results demonstrate the effectiveness of the proposed robust model for microgrid energy management. Full article
(This article belongs to the Special Issue Renewable Energies for Sustainable Development)
Show Figures

Figure 1

23 pages, 6816 KB  
Article
Power Quality Improvement in a Cascaded Multilevel Inverter Interfaced Grid Connected System Using a Modified Inductive–Capacitive–Inductive Filter with Reduced Power Loss and Improved Harmonic Attenuation
by Meenakshi Jayaraman and Sreedevi VT
Energies 2017, 10(11), 1834; https://doi.org/10.3390/en10111834 - 10 Nov 2017
Cited by 21 | Viewed by 6929
Abstract
Recently, multilevel inverters are more researched due to the advantages they offer over conventional voltage source inverters in grid connected applications. Passive filters are connected at the output of these inverters to produce sinusoidal waveforms with reduced harmonics and to satisfy grid interconnection [...] Read more.
Recently, multilevel inverters are more researched due to the advantages they offer over conventional voltage source inverters in grid connected applications. Passive filters are connected at the output of these inverters to produce sinusoidal waveforms with reduced harmonics and to satisfy grid interconnection standard requirements. This work proposes a new passive filter topology for a pulse width modulated five-level cascaded inverter interfaced grid connected system. The proposed passive filter inserts an additional resistance-capacitance branch in parallel to the filter capacitor of the traditional inductive–capacitive–inductive filter in addition to a resistance in series with it to reduce damping power loss. It can attenuate the switching frequency harmonic current components much better than the traditional filter while maintaining the same overall inductance, reduced capacitance and resistance values. The basic parameter design procedure and an approach to discover the parameters of the proposed filter is introduced. Further, a novel methodology using Particle Swarm Optimization (PSO) is recommended to guarantee minimum damping loss while ensuring reduced peak during resonance. In addition, PSO algorithm is newly employed in this work to maximize harmonic attenuation in and around the switching frequency on the premise of allowable values of filter inductance and capacitance. A comparative discussion considering traditional passive filters and the proposed filter is presented and evaluated through experiments conducted on a 110 V, 1 kW five-level grid connected inverter. The modulation algorithm for the multilevel inverter is implemented using a SPARTAN 6-XC6SLX25 Field Programmable Gate Array (FPGA) processor. The analysis shows that the proposed filter not only provides decreased damping power loss but also is capable of providing considerable harmonic ripple reduction in the high frequency band, improved output waveforms and lesser Total Harmonic Distortion (THD) with improved power quality for the multilevel inverter based grid connected system. Full article
(This article belongs to the Special Issue Power Electronics and Power Quality)
Show Figures

Figure 1

Back to TopTop