Sign in to use this feature.

Years

Between: -

Subjects

remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline

Journals

Article Types

Countries / Regions

Search Results (29)

Search Parameters:
Keywords = linear fluorescent lamps

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
12 pages, 5600 KB  
Article
tRNA-Fused Strategy for Enhancing RNA Aptamer Sensor Stability
by Jiawei Zou, Juan Dong, Zhuo Tang, Wei Wang and Feng Du
Chemosensors 2026, 14(6), 128; https://doi.org/10.3390/chemosensors14060128 - 4 Jun 2026
Viewed by 462
Abstract
RNA aptamer sensors are promising for environmental and clinical detection, but their poor stability limits practical application. Here, we developed a tRNA-fused strategy to enhance the stability of unmodified RNA aptamer sensors. The tRNA scaffold was fused to the 3′ end of Spinach [...] Read more.
RNA aptamer sensors are promising for environmental and clinical detection, but their poor stability limits practical application. Here, we developed a tRNA-fused strategy to enhance the stability of unmodified RNA aptamer sensors. The tRNA scaffold was fused to the 3′ end of Spinach aptamer to construct tRNA-Spinach. In vitro stability assays showed that tRNA-Spinach retained 50% of its initial fluorescence for 84 days at 25 °C (60% humidity), a 7-fold improvement compared with native Spinach (12 days). The tRNA-fused strategy also doubled the in vivo half-life of Spinach from 20 min to 40 min in KM mice. Based on this strategy, a tobramycin sensor was constructed, which exhibited a LOD of 30 nM, a linear range of 30–100 nM (R2 = 0.9905). The biosensor could be detected with a handheld UV lamp within 10 min. This tRNA-fused strategy enables room-temperature storage of RNA aptamer sensors without chemical modification, providing a scalable and cost-effective platform for point-of-care diagnostics in resource-limited settings. Full article
(This article belongs to the Section (Bio)chemical Sensing)
Show Figures

Figure 1

15 pages, 1925 KB  
Article
Milling-Assisted Leaching for Mercury Stabilization and Material Recovery from End-of-Life Fluorescent Lamps
by Raşit Sezer and Ayşe Üstünel Çavuş
Metals 2026, 16(3), 341; https://doi.org/10.3390/met16030341 - 18 Mar 2026
Viewed by 817
Abstract
The disposal of end-of-life fluorescent lamps presents significant environmental challenges due to their mercury (Hg) content and the loss of valuable rare earth elements (REEs) contained in phosphor powders, highlighting the need for sustainable recycling strategies. This study proposes an integrated hydrometallurgical process [...] Read more.
The disposal of end-of-life fluorescent lamps presents significant environmental challenges due to their mercury (Hg) content and the loss of valuable rare earth elements (REEs) contained in phosphor powders, highlighting the need for sustainable recycling strategies. This study proposes an integrated hydrometallurgical process for simultaneous mercury removal and material recovery from spent fluorescent lamps. Various leaching agents were initially evaluated for mercury dissolution, and 10% NaOCl was identified as the most effective solution. The optimized system was applied to linear T8 lamps using a combined milling–leaching approach, followed by size-based separation of metallic, glass, and phosphor fractions. Dissolved mercury was precipitated at pH 11 using Na2S, forming crystalline α-HgS (cinnabar), as confirmed by XRD, and reducing the residual mercury concentration to 2.7 µg/L. The metallic fraction was recovered as an aluminum-based alloy containing 20.6 wt.% Cu and 10.9 wt.% Zn with low iron content, while the phosphor-rich fraction yielded approximately 50% REE extraction, followed by oxalate precipitation of yttrium-based compounds. The developed process enables efficient mercury stabilization and selective recovery of valuable materials, supporting environmentally secure and resource-efficient fluorescent lamp recycling. Full article
(This article belongs to the Special Issue Studies on Metal Leaching, Extraction and Recovery)
Show Figures

Figure 1

24 pages, 795 KB  
Review
Recovery of Antimony from Secondary Sources: Extraction Strategies and Analytical Approaches
by Neli Mintcheva, Marinela Panayotova and Gospodinka Gicheva
Appl. Sci. 2026, 16(6), 2628; https://doi.org/10.3390/app16062628 - 10 Mar 2026
Cited by 1 | Viewed by 1361
Abstract
Antimony (Sb) is a key element used in flame retardants, lead–acid batteries, and polymer catalysis, and it is classified as a critical raw material. Its quantity for the worldwide economy is limited due to restricted natural resources and partial recycling of by-products. This [...] Read more.
Antimony (Sb) is a key element used in flame retardants, lead–acid batteries, and polymer catalysis, and it is classified as a critical raw material. Its quantity for the worldwide economy is limited due to restricted natural resources and partial recycling of by-products. This is why recovering Sb from secondary sources is becoming increasingly important in terms of technological and economic aspects for ensuring its sustainable and safety supply. In this paper, we review the possibilities for extraction of antimony from various waste sources, such as ore processing and metal recovery residues, electronic and plastic waste, lead-antimony-containing waste, spent catalysts, fluorescent lamps, incinerated municipal waste, and the applied methods of waste processing (pyrometallurgy, hydrometallurgy, solvometallurgy) used to achieve recovery in high yield and purity. The methods for antimony quantification and speciation are also discussed and described in terms of principle of the technique, linear concentration range, limit of detection, and coupling with other techniques. As the concentration of Sb in environmental and biological samples is usually very low and requires good selectivity and sensitivity of the analytical method, suitable techniques for sample preparation and subsequent instrumental measurement are also included. Full article
(This article belongs to the Special Issue Sustainable Strategies in Waste Recycling and Metal Recovery)
Show Figures

Figure 1

18 pages, 3865 KB  
Article
Rapid Authentication of Intact Stingless Bee Honey (SBH) by Portable LED-Based Fluorescence Spectroscopy and Chemometrics
by Diding Suhandy, Dimas Firmanda Al Riza, Meinilwita Yulia, Kusumiyati Kusumiyati, Mareli Telaumbanua and Hirotaka Naito
Foods 2024, 13(22), 3648; https://doi.org/10.3390/foods13223648 - 16 Nov 2024
Cited by 4 | Viewed by 2639
Abstract
Indonesian stingless bee honey (SBH) of Geniotrigona thoracica is popular and traded at an expensive price. Brown rice syrup (RS) is frequently used as a cheap adulterant for an economically motivated adulteration (EMA) in SBH. In this study, authentic Indonesian Geniotrigona thoracica SBH [...] Read more.
Indonesian stingless bee honey (SBH) of Geniotrigona thoracica is popular and traded at an expensive price. Brown rice syrup (RS) is frequently used as a cheap adulterant for an economically motivated adulteration (EMA) in SBH. In this study, authentic Indonesian Geniotrigona thoracica SBH of Acacia mangium (n = 100), adulterated SBH (n = 120), fake SBH (n = 100), and RS (n = 200) were prepared. In short, 2 mL of each sample was dropped directly into an innovative sample holder without any sample preparation including no dilution. Fluorescence intensity was acquired using a fluorescence spectrometer. This portable instrument is equipped with a 365 nm LED lamp as the fixed excitation source. Principal component analysis (PCA) was calculated for the smoothed spectral data. The results showed that the authentic SBH and non-SBH (adulterated SBH, fake SBH, and RS) samples could be well separated using the smoothed spectral data. The cumulative percentage variance of the first two PCs, 98.4749% and 98.4425%, was obtained for calibration and validation, respectively. The highest prediction accuracy was 99.5% and was obtained using principal component analysis–linear discriminant analysis (PCA-LDA). The best partial least square (PLS) calibration was obtained using the combined interval with R2cal = 0.898 and R2val = 0.874 for calibration and validation, respectively. In the prediction, the developed model could predict the adulteration level in the adulterated honey samples with an acceptable ratio of prediction to deviation (RPD) = 2.282, and range error ratio (RER) = 6.612. Full article
(This article belongs to the Section Food Analytical Methods)
Show Figures

Figure 1

12 pages, 5666 KB  
Article
Research on the Key Technology of a Fluorescence Detection Device Using the RT-LAMP Method for Instant Detection
by Hongzhuang Guo, Ping Gong, Tingting Sun, Xin Wang and Hao Zhang
Micromachines 2024, 15(8), 1044; https://doi.org/10.3390/mi15081044 - 18 Aug 2024
Viewed by 1889
Abstract
As of 31 October 2023, there have been 771,795,258 confirmed cases of COVID-19 globally. Developing simple, portable, and reliable testing devices has become increasingly important. This paper presents a point-of-care testing (POCT) device for COVID-19 based on the dual-excitation fluorescence RT-LAMP method, which [...] Read more.
As of 31 October 2023, there have been 771,795,258 confirmed cases of COVID-19 globally. Developing simple, portable, and reliable testing devices has become increasingly important. This paper presents a point-of-care testing (POCT) device for COVID-19 based on the dual-excitation fluorescence RT-LAMP method, which is derived from the principles of RT-LAMP-based COVID-19 detection kits available in the market. The key design solutions of the device were simulated and modeled. Key performance metrics such as detection repeatability and linearity were validated. Comparative experiments with the RT-qPCR detection method were conducted to verify the accuracy and reliability of the device. Additionally, the device’s detection sensitivity and accuracy were assessed. Experimental results show that the repeatability coefficient of variation (CV) value is ≤0.09%; the linearity R2 for the FAM channel is 0.9977 and that for the HEX channel is 0.9899; it exhibits good anti-interference performance, with negligible cross-channel interference; the temperature stability is ±0.062 °C, the temperature accuracy is less than 0.2 °C, and there is no significant temperature overshoot during the heating process. Compared with the real-time quantitative PCR (RT-qPCR) instrument, the positive agreement rate is 100% and the negative agreement rate is 95.0%. This research provides a foundational basis for the development of equipment for the prevention of infectious diseases and clinical diagnostics. Full article
Show Figures

Figure 1

31 pages, 19503 KB  
Article
An Experimental Analysis of Three-Phase Low-Voltage Power Factor Controllers Used in a Deforming Regime
by Corina Maria Diniș and Gabriel Nicolae Popa
Energies 2024, 17(7), 1647; https://doi.org/10.3390/en17071647 - 29 Mar 2024
Cited by 4 | Viewed by 3102
Abstract
In industry, to improve the power factor in low-voltage power substations, a power factor controller (the most used method) can be installed which connects capacitors banks (connected, or not, with coils) in the electrical installation. The most important parameters of power engineering are [...] Read more.
In industry, to improve the power factor in low-voltage power substations, a power factor controller (the most used method) can be installed which connects capacitors banks (connected, or not, with coils) in the electrical installation. The most important parameters of power engineering are the power factors that indicate the efficiency of energy use. Currently, many non-linear consumers (more single-phase than three-phase) are used on low voltages. Harmonics (currents and/or voltages) are the most important dynamic component of power quality, affecting electrical equipment performance and also reducing power factors. The purpose of this analysis is to increase the displacement power factor and to decrease the total harmonic distortion (for the current) in the conditions where there are linear and non-linear consumers, where the power factor must be improved with capacitors banks. Relevant different consumers have been selected for both the industry and the home sector, as follows: inductive motors that are linear, inductive consumers, compact fluorescent lamps that are non-linear, and capacitive consumers. This analysis was carried out depending on the number of steps used for the power factor controller, the values of the capacitors banks, the AC reactor (connected in series with all consumers), and the LC shunt filters. For a slight deformation regime, a large number of capacitors banks with different values ensure a finer adjustment of the displacement factor. The maximum number of steps that regulators can command should not necessarily be used (the reliability of the installation decreases with the increase in the number of capacitors banks), but a reduced number of steps can be used, which can lead to higher values of displacement power factors. To improve the deforming regime and to increase the displacement power factor, the use of LC shunt filters, connected to a small number of steps, will also increase the displacement power factor (over 0.9) and decrease the total harmonic distortion (up to 7–10%) for the current. Weaker results were obtained with AC reactors connected to the power supply phases of consumers and, if a larger number of stages were used, to which LC shunt filters were connected, these filters become difficult to calibrate (resonances occur). Full article
Show Figures

Figure 1

12 pages, 4601 KB  
Article
A Point-of-Care Nucleic Acid Quantification Method by Counting Light Spots Formed by LAMP Amplicons on a Paper Membrane
by Yanju Chen, Yuanyuan Zhu, Cheng Peng, Xiaofu Wang, Jian Wu, Huan Chen and Junfeng Xu
Biosensors 2024, 14(3), 139; https://doi.org/10.3390/bios14030139 - 10 Mar 2024
Cited by 7 | Viewed by 3810
Abstract
Nucleic acid quantification, allowing us to accurately know the copy number of target nucleic acids, is significant for diagnosis, food safety, agricultural production, and environmental protection. However, current digital quantification methods require expensive instruments or complicated microfluidic chips, making it difficult to popularize [...] Read more.
Nucleic acid quantification, allowing us to accurately know the copy number of target nucleic acids, is significant for diagnosis, food safety, agricultural production, and environmental protection. However, current digital quantification methods require expensive instruments or complicated microfluidic chips, making it difficult to popularize in the point-of-care detection. Paper is an inexpensive and readily available material. In this study, we propose a simple and cost-effective paper membrane-based digital loop-mediated isothermal amplification (LAMP) method for nucleic acid quantification. In the presence of DNA fluorescence dyes, the high background signals will cover up the amplicons-formed bright spots. To reduce the background fluorescence signals, a quencher-fluorophore duplex was introduced in LAMP primers to replace non-specific fluorescence dyes. After that, the amplicons-formed spots on the paper membrane can be observed; thus, the target DNA can be quantified by counting the spots. Take Vibrio parahaemolyticus DNA detection as an instance, a good linear relationship is obtained between the light spots and the copy numbers of DNA. The paper membrane-based digital LAMP detection can detect 100 copies target DNA per reaction within 30 min. Overall, the proposed nucleic acid quantification method has the advantages of a simple workflow, short sample-in and answer-out time, low cost, and high signal-to-noise, which is promising for application in resourced limited areas. Full article
(This article belongs to the Special Issue Biosensors for Monitoring Pathogenic Agents (Volume II))
Show Figures

Figure 1

15 pages, 3348 KB  
Article
Immunoassay System Based on the Technology of Time-Resolved Fluorescence Resonance Energy Transfer
by Zhengping Xu, Hong Zhou, Li Li, Zhang Chen, Xin Zhang, Yongtong Feng, Jianping Wang, Yuan Li and Yanfan Wu
Sensors 2024, 24(5), 1430; https://doi.org/10.3390/s24051430 - 22 Feb 2024
Cited by 2 | Viewed by 3739
Abstract
To enhance the specificity and sensitivity, cut the cost, and realize joint detection of multiple indicators, an immunoassay system based on the technology of time-resolved fluorescence resonance energy transfer (TR-FRET) was studied. Due to the FRET of the reagent, the donor probe and [...] Read more.
To enhance the specificity and sensitivity, cut the cost, and realize joint detection of multiple indicators, an immunoassay system based on the technology of time-resolved fluorescence resonance energy transfer (TR-FRET) was studied. Due to the FRET of the reagent, the donor probe and acceptor probe emitted specific fluorescence to enhance specificity. Long-lifetime specific fluorescence from the acceptor probe was combined with time-resolved technology to enhance sensitivity. A xenon flash lamp and a photomultiplier tube (PMT) were selected as the light source and detector, respectively. A filter-switching mechanism was placed in the light path, so the fluorescence signal from the donor and acceptor was measured alternately. The instrument’s design is given, and some specificI parts are described in detail. Key technical specifications of the instrument and procalcitonin (PCT), C-reactive protein (CRP), and interleukin-6(IL-6) were tested, and the test results were presented subsequently. The CV value of the self-designed counting module is better than 0.01%, and the instrument noises for 620 nm and 665 nm are 41.44 and 10.59, respectively. When set at 37 °C, the temperature bias (B) is 0.06 °C, and the temperature fluctuation is 0.10 °C. The CV and bias are between ±3% and 5%, respectively, when pipetting volumes are between 10 μL and 100 μL. Within the concentration range of 0.01 nM to 10 nM, the luminescence values exhibit linear regression correlation coefficients greater than 0.999. For PCT detection, when the concentration ranges from 0.02 ng/mL to 50 ng/mL, the correlation coefficient of linear fitting exceeds 0.999, and the limit of quantification is 0.096 ng/mL. For CRP and IL-6, the detection concentration ranges from 0 ng/mL to 500 ng/mL and 0 ng/mL to 20 ng/mL, respectively, with limits of quantification of 2.70 ng/mL and 2.82 ng/mL, respectively. The experimental results confirm the feasibility of the technical and instrumental solutions. Full article
(This article belongs to the Section Biomedical Sensors)
Show Figures

Figure 1

14 pages, 3088 KB  
Article
The Authentication of Gayo Arabica Green Coffee Beans with Different Cherry Processing Methods Using Portable LED-Based Fluorescence Spectroscopy and Chemometrics Analysis
by Meinilwita Yulia, Analianasari Analianasari, Slamet Widodo, Kusumiyati Kusumiyati, Hirotaka Naito and Diding Suhandy
Foods 2023, 12(23), 4302; https://doi.org/10.3390/foods12234302 - 28 Nov 2023
Cited by 13 | Viewed by 4674
Abstract
Aceh is an important region for the production of high-quality Gayo arabica coffee in Indonesia. In this area, several coffee cherry processing methods are well implemented including the honey process (HP), wine process (WP), and natural process (NP). The most significant difference between [...] Read more.
Aceh is an important region for the production of high-quality Gayo arabica coffee in Indonesia. In this area, several coffee cherry processing methods are well implemented including the honey process (HP), wine process (WP), and natural process (NP). The most significant difference between the three coffee cherry processing methods is the fermentation process: HP is a process of pulped coffee bean fermentation, WP is coffee cherry fermentation, and NP is no fermentation. It is well known that the WP green coffee beans are better in quality and are sold at higher prices compared with the HP and NP green coffee beans. In this present study, we evaluated the utilization of fluorescence information to discriminate Gayo arabica green coffee beans from different cherry processing methods using portable fluorescence spectroscopy and chemometrics analysis. A total of 300 samples were used (n = 100 for HP, WP, and NP, respectively). Each sample consisted of three selected non-defective green coffee beans. Fluorescence spectral data from 348.5 nm to 866.5 nm were obtained by exciting the intact green coffee beans using a portable spectrometer equipped with four 365 nm LED lamps. The result showed that the fermented green coffee beans (HP and WP) were closely mapped and mostly clustered on the left side of PC1, with negative scores. The non-fermented (NP) green coffee beans were clustered mostly on the right of PC1 with positive scores. The results of the classification using partial least squares–discriminant analysis (PLS-DA), linear discriminant analysis (LDA), and principal component analysis–linear discriminant analysis (PCA-LDA) are acceptable, with an accuracy of more than 80% reported. The highest accuracy of prediction of 96.67% was obtained by using the PCA-LDA model. Our recent results show the potential application of portable fluorescence spectroscopy using LED lamps to classify and authenticate the Gayo arabica green coffee beans according to their different cherry processing methods. This innovative method is more affordable and could be easy to implement (in terms of both affordability and practicability) in the coffee industry in Indonesia. Full article
Show Figures

Figure 1

12 pages, 2915 KB  
Article
Preparation of Microcrystalline Cellulose-Derived Carbon Dots as a Sensor for Fe3+ Detection
by Jiang Fan, Lei Kang, Jinlong Gao, Xu Cheng, Qing Zhang and Yunlong Wu
Coatings 2023, 13(12), 1979; https://doi.org/10.3390/coatings13121979 - 21 Nov 2023
Cited by 6 | Viewed by 2480
Abstract
In this article, nitrogen-doped carbon dots (N-CDs) were prepared by a hydrothermal method using microcrystalline cellulose as the carbon source and polyethylenimine as the nitrogen source. The ratio of microcrystalline cellulose to polyethylenimine added exerted a great influence on the fluorescence quantum yield [...] Read more.
In this article, nitrogen-doped carbon dots (N-CDs) were prepared by a hydrothermal method using microcrystalline cellulose as the carbon source and polyethylenimine as the nitrogen source. The ratio of microcrystalline cellulose to polyethylenimine added exerted a great influence on the fluorescence quantum yield of N-CDs. The fluorescence intensity of N-CDs 2 was significantly affected by the solvent type and pH value, but not influenced by the time of irradiation with the UV lamp. Intriguingly, N-CDs 2 could be applied to temperature sensing (30~70 °C). With the addition of Fe3+ (20 ppm), the fluorescence of N-CDs 2 was greatly quenched, and the quenching rate reached 82.84%. The fluorescence intensity of N-CDs 2 showed a good linear relationship (R2 = 0.995) with Fe3+ concentrations (0~14 ppm), and they achieved a limit of detection of 0.21 ppm. In addition, N-CDs 2 could also effectively detect Fe3+ in real water samples, showing a good recovery rate (98.25%~102.75%) and low relative standard deviation (less than 3%). According to the fluorescence lifetime data, the fluorescence quenching of N-CDs by Fe3+ might be a static process. Full article
Show Figures

Figure 1

19 pages, 3125 KB  
Article
Non-Targeted Detection and Quantification of Food Adulteration of High-Quality Stingless Bee Honey (SBH) via a Portable LED-Based Fluorescence Spectroscopy
by Diding Suhandy, Dimas Firmanda Al Riza, Meinilwita Yulia and Kusumiyati Kusumiyati
Foods 2023, 12(16), 3067; https://doi.org/10.3390/foods12163067 - 15 Aug 2023
Cited by 13 | Viewed by 3940
Abstract
Stingless bee honey (SBH) is rich in phenolic compounds and available in limited quantities. Authentication of SBH is important to protect SBH from adulteration and retain the reputation and sustainability of SBH production. In this research, we use portable LED-based fluorescence spectroscopy to [...] Read more.
Stingless bee honey (SBH) is rich in phenolic compounds and available in limited quantities. Authentication of SBH is important to protect SBH from adulteration and retain the reputation and sustainability of SBH production. In this research, we use portable LED-based fluorescence spectroscopy to generate and measure the fluorescence intensity of pure SBH and adulterated samples. The spectrometer is equipped with four UV-LED lamps (peaking at 365 nm) as an excitation source. Heterotrigona itama, a popular SBH, was used as a sample. 100 samples of pure SBH and 240 samples of adulterated SBH (levels of adulteration ranging from 10 to 60%) were prepared. Fluorescence spectral acquisition was measured for both the pure and adulterated SBH samples. Principal component analysis (PCA) demonstrated that a clear separation between the pure and adulterated SBH samples could be established from the first two principal components (PCs). A supervised classification based on soft independent modeling of class analogy (SIMCA) achieved an excellent classification result with 100% accuracy, sensitivity, specificity, and precision. Principal component regression (PCR) was superior to partial least squares regression (PLSR) and multiple linear regression (MLR) methods, with a coefficient of determination in prediction (R2p) = 0.9627, root mean squared error of prediction (RMSEP) = 4.1579%, ratio prediction to deviation (RPD) = 5.36, and range error ratio (RER) = 14.81. The LOD and LOQ obtained were higher compared to several previous studies. However, most predicted samples were very close to the regression line, which indicates that the developed PLSR, PCR, and MLR models could be used to detect HFCS adulteration of pure SBH samples. These results showed the proposed portable LED-based fluorescence spectroscopy has a high potential to detect and quantify food adulteration in SBH, with the additional advantages of being an accurate, affordable, and fast measurement with minimum sample preparation. Full article
(This article belongs to the Special Issue Novel Techniques for Food Authentication)
Show Figures

Figure 1

12 pages, 4509 KB  
Article
Folic Acid Adjustive Polydopamine Organic Nanoparticles Based Fluorescent Probe for the Selective Detection of Mercury Ions
by Lijuan Chen, Changchang Chen, Yehan Yan, Linlin Yang, Renyong Liu, Jiajia Zhang, Xin Zhang and Chenggen Xie
Polymers 2023, 15(8), 1892; https://doi.org/10.3390/polym15081892 - 14 Apr 2023
Cited by 12 | Viewed by 3471
Abstract
Polydopamine fluorescent organic nanomaterials present unique physicochemical and biological properties, which have great potential application in bio-imaging and chemical sensors. Here, folic acid (FA) adjustive polydopamine (PDA) fluorescent organic nanoparticles (FA-PDA FONs) were prepared by a facile one-pot self-polymerization strategy using dopamine (DA) [...] Read more.
Polydopamine fluorescent organic nanomaterials present unique physicochemical and biological properties, which have great potential application in bio-imaging and chemical sensors. Here, folic acid (FA) adjustive polydopamine (PDA) fluorescent organic nanoparticles (FA-PDA FONs) were prepared by a facile one-pot self-polymerization strategy using dopamine (DA) and FA as precursors under mild conditions. The as-prepared FA-PDA FONs had an average size of 1.9 ± 0.3 nm in diameter with great aqueous dispersibility, and the FA-PDA FONs solution exhibit intense blue fluorescence under 365 nm UV lamp, and the quantum yield is ~8.27%. The FA-PDA FONs could be stable in a relatively wide pH range and high ionic strength salt solution, and the fluorescence intensities are constant. More importantly, here we developed a method for rapidly selective and sensitive detection of mercury ions (Hg2+) within 10 s using FA-PDA FONs based probe, the fluorescence intensities of FA-PDA FONs presented a great linear relationship to Hg2+ concentration, the linear range and limit of detection (LOD) were 0–18 µM and 0.18 µM, respectively. Furthermore, the feasibility of the developed Hg2+ sensor was verified by determination of Hg2+ in mineral water and tap water samples with satisfactory results. Full article
(This article belongs to the Special Issue Synthesis and Applications of Polymer-Based Nanocomposites)
Show Figures

Graphical abstract

13 pages, 6072 KB  
Communication
Study of the Radiation Pattern and Frequency Response of a Short Linear Antenna Surrounded by Discharge Tubes for the Development of Rapidly Adjustable Wideband Antenna Systems
by Hailu Wang, Xingbao Lyu, Jingfeng Yao, Aleksandr M. Astafiev and He-Ping Li
Electronics 2023, 12(6), 1277; https://doi.org/10.3390/electronics12061277 - 7 Mar 2023
Cited by 4 | Viewed by 2908
Abstract
Plasma antenna systems consisting of discharge elements have great practical application prospects due to their ability to quickly adjust parameters over a wide range. In this work, the radiation patterns of a 30 mm long linear antenna surrounded by 16 standard T8 fluorescent [...] Read more.
Plasma antenna systems consisting of discharge elements have great practical application prospects due to their ability to quickly adjust parameters over a wide range. In this work, the radiation patterns of a 30 mm long linear antenna surrounded by 16 standard T8 fluorescent lamps were measured by using a spectrum analyzer with a tracking generator. The radiation pattern of the system is measured by connecting the output of the spectrum analyzer tracking generator to a linear antenna and connecting the input of the spectrum analyzer to the receiving broadband horn antenna. The work features experimental measurements over a wide frequency range of 0.5 to 1.5 GHz and a wide discharge with current values from 35 to 200 mA. The specific frequency band and uniquely selected geometry allowed for the investigation of both the in-phase and out-of-phase antenna modes, while some modes were found to have a narrow directional radiation pattern, within 50 degrees, with a beam width of −3 dB. The parameters of the gas-discharge plasma were also evaluated using drift theory, as well as using the microwave transmission of the 20 GHz signal. The electron density value corresponding to the used discharge currents was approximately from 4 × 1011 to 7 × 1010 cm−3. Full article
Show Figures

Figure 1

17 pages, 5695 KB  
Article
Pyrene-Based Fluorescent Probe for “Off-on-Off” Sequential Detection of Cu2+ and CN with HeLa Cells Imaging
by Muthaiah Shellaiah, Parthiban Venkatesan, Natesan Thirumalaivasan, Shu-Pao Wu and Kien-Wen Sun
Chemosensors 2023, 11(2), 115; https://doi.org/10.3390/chemosensors11020115 - 4 Feb 2023
Cited by 62 | Viewed by 5989
Abstract
The novel pyrene-appended Schiff base probe L with aggregation-induced emissions (AIE) relevant to an increase in water fractions (0–90%) is synthesized and applied in sequentially detecting Cu2+ and CN. The pyrene-based probe L firstly induces the excimer formation in the [...] Read more.
The novel pyrene-appended Schiff base probe L with aggregation-induced emissions (AIE) relevant to an increase in water fractions (0–90%) is synthesized and applied in sequentially detecting Cu2+ and CN. The pyrene-based probe L firstly induces the excimer formation in the presence of Cu2+. However, the process can be reversed by sequentially adding CN, which is demonstrated using the fluorescence “Off-On-Off” response in semi-aqueous media ethanol water (v/v = 7/3) under physiological pH (5 mM HEPES, pH 7.0). The Job’s plot, mass analysis, 1H NMR titrations, and density functional theory (DFT) interrogations confirm the 2:1 stoichiometry of excimer complex L–Cu2+-L*, preferential binding atoms, and CN tuned complex reversibility. Based on the photoluminescence (PL) titration, the association constant of L to Cu2+ is determined as 4.95 × 106 M−1. From standard deviation and linear fittings, the detection limits (LODs) of Cu2+ and CN are estimated as 219 nM and 580 nM, respectively. The practicality of Cu2+ and CN detection is demonstrated using a TLC plate and a blended polymer membrane through which significant color changes under a UV lamp can be monitored. Moreover, utility of the designed probe L towards biological application with low toxicity is demonstrated by detecting Cu2+ and CN inside HeLa cells. The responses of the probe to Cu(II) ions were also verified using living HeLa cells imaging. Full article
(This article belongs to the Special Issue Chemosensors for Ion Detection)
Show Figures

Figure 1

17 pages, 4058 KB  
Article
Polyindole-Derived Nitrogen-Doped Graphene Quantum Dots-Based Electrochemical Sensor for Dopamine Detection
by Anjitha Thadathil, Dipin Thacharakkal, Yahya A. Ismail and Pradeepan Periyat
Biosensors 2022, 12(12), 1063; https://doi.org/10.3390/bios12121063 - 22 Nov 2022
Cited by 30 | Viewed by 4038
Abstract
The sensitive monitoring of dopamine levels in the human body is of utmost importance since its abnormal levels can cause a variety of medical and behavioral problems. In this regard, we report the synthesis of nitrogen-doped graphene quantum dots (N-GQDs) from polyindole (PIN) [...] Read more.
The sensitive monitoring of dopamine levels in the human body is of utmost importance since its abnormal levels can cause a variety of medical and behavioral problems. In this regard, we report the synthesis of nitrogen-doped graphene quantum dots (N-GQDs) from polyindole (PIN) via a facile single-step hydrothermal synthetic strategy that can act as an efficient electrochemical catalyst for the detection of dopamine (DA). The average diameter of N-GQDs was ∼5.2 nm and showed a C/N atomic ratio of ∼2.75%. These N-GQDs exhibit a cyan fluorescence color under irradiation from a 365 nm lamp, while PIN has no characteristic PL. The presence of richly N-doped graphitic lattices in the N-GQDs possibly accounts for the improved catalytic activity of N-GQDs/GCE towards electrocatalytic DA detection. Under optimum conditions, this novel N-GQDs-modified electrode exhibits superior selectivity and sensitivity. Moreover, it could detect as low as 0.15 nM of DA with a linear range of 0.001–1000 µM. In addition, the outstanding sensing attributes of the detector were extended to the real samples as well. Overall, our findings evidence that N-GQDs-based DA electrochemical sensors can be synthesized from PIN precursor and could act as promising EC sensors in medical diagnostic applications. Full article
(This article belongs to the Special Issue Polymer-Metal-Carbon-Based Hybrid Materials for Biosensors)
Show Figures

Figure 1

Back to TopTop