Sign in to use this feature.

Years

Between: -

Subjects

remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline

Journals

Article Types

Countries / Regions

Search Results (46)

Search Parameters:
Keywords = leucite

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
15 pages, 2256 KiB  
Article
In Vivo Wear Analysis of Leucite-Reinforced Ceramic Inlays/Onlays After 14 Years
by Ragai-Edward Matta, Lara Berger, Oleksandr Sednyev, Dennis Bäuerle, Eva Maier, Werner Adler and Michael Taschner
Materials 2025, 18(15), 3446; https://doi.org/10.3390/ma18153446 - 23 Jul 2025
Viewed by 280
Abstract
Material wear significantly impacts the clinical success and longevity of dental ceramic restorations. This in vivo study aimed to assess the wear behavior of IPS Empress® glass-ceramic inlays and onlays over 14 years, considering the influence of different antagonist materials. Fifty-four indirect [...] Read more.
Material wear significantly impacts the clinical success and longevity of dental ceramic restorations. This in vivo study aimed to assess the wear behavior of IPS Empress® glass-ceramic inlays and onlays over 14 years, considering the influence of different antagonist materials. Fifty-four indirect restorations of 21 patients were available for comprehensive wear analysis, with complete follow-up data for up to 14 years. Three-dimensional measurements relied on digitized epoxy resin models produced immediately post-insertion (baseline) and subsequently at 2, 4, and 14 years. The occlusal region on the baseline model was delineated for comparative analysis. Three-dimensional superimpositions with models from subsequent time points were executed to assess wear in terms of average linear wear and volumetric loss. Statistical analyses were conducted in R (version 4.4.1), employing Mann–Whitney U tests (material comparisons) and Wilcoxon signed rank tests (time point comparisons), with a significance threshold of p ≤ 0.05. During the entire study period, an increase in wear was observed at each assessment interval, gradually stabilizing over time. Significant differences in substance loss were found between the follow-up time points, both for mean (−0.536 ± 0.249 mm after 14a) and integrated distance (−18,935 ± 11,711 mm3 after 14a). In addition, significantly higher wear was observed after 14 years with gold as antagonist compared to other materials (p ≤ 0.03). The wear behavior of IPS Empress® ceramics demonstrates clinically acceptable long-term outcomes, with abrasion characteristics exhibiting stabilization over time. Full article
(This article belongs to the Special Issue Advanced Dental Materials: From Design to Application, Second Volume)
Show Figures

Figure 1

22 pages, 7336 KiB  
Article
The Formation Process and Mechanism of Total Activated Potassium During the Preparation of Si–Ca–K–Mg Fertilizer from Molybdenum Tailings
by Tuanliu Hu, Yifan Li, Aihua Xiang, Xinglan Li and Kun Liu
Minerals 2025, 15(5), 450; https://doi.org/10.3390/min15050450 - 26 Apr 2025
Viewed by 336
Abstract
Silicon–calcium–potassium–magnesium fertilizer (Si–Ca–K–Mg fertilizer), a critical acidic soil conditioner for remediating polluted acidic soils, encounters a significant challenge: substantial potassium loss through flue gas during high–temperature calcination, which increases production costs. This study optimized the blending ratio of molybdenum tailings (MTs) with CaCO [...] Read more.
Silicon–calcium–potassium–magnesium fertilizer (Si–Ca–K–Mg fertilizer), a critical acidic soil conditioner for remediating polluted acidic soils, encounters a significant challenge: substantial potassium loss through flue gas during high–temperature calcination, which increases production costs. This study optimized the blending ratio of molybdenum tailings (MTs) with CaCO3 and CaSO4, systematically investigating the interplay between clinker–soluble potassium, volatile potassium loss, and total activated potassium content during calcination. Key findings include the large–scale utilization of molybdenum tailings; a mass ratio of mMTs:mCaCO3:mCaSO4 = 1:0.5:1.0 leads to a total activated K2O content of 3.05 wt.%. Enhancing nutrient efficiency by increasing the proportion of additives (with a mass ratio of 1:0.7:0.4) results in a total activated K2O content of 4.50 wt.%, which is 1.5 times the national standard. Mechanistically, calcination decomposes potassium feldspar (K–feldspar) in the tailings into leucite and SiO2. CaO derived from CaCO3 reacts with SiO2 to form calcium silicate, facilitating the decomposition of leucite into water–soluble kaliophilite. Simultaneously, thermal diffusion promotes the ion exchange between Ca2+ of CaSO4 and K+ of feldspar and leucite, thereby forming potassium sulfate. However, part of this potassium sulfate, along with some water–soluble kaliophilite, volatilizes at high temperatures, contributing to flue gas loss. Recycling the lost potassium back into fertilizers enables complete potassium utilization. This work establishes a robust framework for efficiently producing Si–Ca–K–Mg fertilizer from molybdenum tailings, addressing key challenges in potassium retention and resource recycling during industrial synthesis. Full article
Show Figures

Graphical abstract

38 pages, 3106 KiB  
Review
Exploring the Properties and Indications of Chairside CAD/CAM Materials in Restorative Dentistry
by Codruţa-Eliza Ille, Anca Jivănescu, Daniel Pop, Eniko Tunde Stoica, Razvan Flueras, Ioana-Cristina Talpoş-Niculescu, Raluca Mioara Cosoroabă, Ramona-Amina Popovici and Iustin Olariu
J. Funct. Biomater. 2025, 16(2), 46; https://doi.org/10.3390/jfb16020046 - 1 Feb 2025
Cited by 4 | Viewed by 3125
Abstract
The present review provides an up-to-date overview of chairside CAD/CAM materials used in restorative dentistry, focusing on their classification, properties, and clinical applications. If CAD/CAM technology was only an aspiration in the past, a higher proportion of clinics are employing it nowadays. The [...] Read more.
The present review provides an up-to-date overview of chairside CAD/CAM materials used in restorative dentistry, focusing on their classification, properties, and clinical applications. If CAD/CAM technology was only an aspiration in the past, a higher proportion of clinics are employing it nowadays. The market is overflowing with biomaterials, and these materials are constantly evolving, making it challenging for practitioners to choose the most appropriate one, especially in correlation with patients’ medical diseases. The evolution of CAD/CAM technology has revolutionized dental practice, enabling the efficient fabrication of high-quality restorations in a single appointment. The main categories of chairside CAD/CAM materials include feldspathic ceramics, leucite-reinforced ceramics, lithium disilicate, zirconia, hybrid ceramics, and acrylic resins. The mechanical, physical, and aesthetic properties of these materials are discussed, along with their advantages and limitations for different clinical scenarios. Factors influencing material selection, such as strength, aesthetics, and ease of use, are also assessed. Ultimately, the guiding principle of dentistry is minimally invasive treatment following the particularity of the clinical case to obtain the envisioned result. Correlating all these factors, a simple, up-to-date classification is required to begin an individualized treatment. By synthesizing current evidence, this comprehensive review aims to guide clinicians in selecting appropriate chairside CAD/CAM materials to achieve optimal functional and aesthetic outcomes in restorative procedures. The integration of digital workflows and continued development of novel materials promise to further enhance the capabilities of chairside CAD/CAM systems in modern dental practice. Full article
(This article belongs to the Special Issue State-of-the-Art Dental Adhesives and Restorative Composites)
Show Figures

Figure 1

24 pages, 3547 KiB  
Article
Evidence of the Formation of Crystalline Aluminosilicate Phases in Glass-Ceramics by Calcination of Alkali-Brick Aggregates, Enabling Cs+, Rb+, Co2+, and Sr2+ Encapsulation
by Abdel Boughriet, Gildas Doyemet, Nicole Poumaye, Véronique Alaimo, Sandra Ventalon, Viviane Bout-Roumazeilles and Michel Wartel
Appl. Sci. 2025, 15(3), 1379; https://doi.org/10.3390/app15031379 - 29 Jan 2025
Viewed by 754
Abstract
The feasibility of using brick aggregates for the preparation of aluminosilicate “glass-ceramic” forms as a novel cementitious composite capable of immobilizing radioactive elements was examined. Raw brick was initially activated with sodium hydroxide. X-ray diffraction analysis (XRD) confirmed zeolites (Na-A and Na-P), illite, [...] Read more.
The feasibility of using brick aggregates for the preparation of aluminosilicate “glass-ceramic” forms as a novel cementitious composite capable of immobilizing radioactive elements was examined. Raw brick was initially activated with sodium hydroxide. X-ray diffraction analysis (XRD) confirmed zeolites (Na-A and Na-P), illite, and sand (quartz) as major phases. Thermal analysis showed several successive events: dehydration/dehydroxylation of illite, followed by degradation of illite and zeolites. Upon heating to 1000 °C, scanning electron microscopy and XRD provided evidence of the presence of novel crystalline aluminosilicate forms (analcime and leucite in the form of solid solutions). Then, upon heating to 1150 °C, the thermal process led to the additional formation of mullite and an amorphous silica-rich phase. The latter resulted from silica melting taking place, owing to the involvement of low-melting-point components on sand grains. Alkali-brick particles were then doped with Cs+, Rb+, Ca2+, and Sr2+ ions (individually) and subsequently heated at different temperatures. The corrosion resistance of the heated materials was examined in a hydrochloride acid solution. The aim was to highlight (i) the enhanced cationic-immobilization capacity of crystalline aluminosilicate phases embedded inside amorphous silica, and (ii) the role of sand in the creation of brick-based glass ceramics. Full article
(This article belongs to the Special Issue Novel Ceramic Materials: Processes, Properties and Applications)
Show Figures

Figure 1

16 pages, 3950 KiB  
Article
Are Dental Prophylaxis Protocols Safe for CAD-CAM Restorative Materials? Surface Characteristics and Fatigue Strength
by Lucas Saldanha da Rosa, Luiza Freitas Brum Souza, Rafaela Oliveira Pilecco, Thaís Andressa Cavalcante Kluch, Felipe Somavilla Binotto, Vitória Zanetti Henriques, Cornelis Johannes Kleverlaan, Gabriel Kalil Rocha Pereira and João Paulo Mendes Tribst
Coatings 2024, 14(12), 1510; https://doi.org/10.3390/coatings14121510 - 30 Nov 2024
Cited by 1 | Viewed by 1075
Abstract
The surface of dental materials is exposed to various prophylaxis protocols during routine dental care. However, the impact of these protocols on the functional properties of the material’s surface remains unclear. This study investigates the influence of different dental prophylaxis protocols on the [...] Read more.
The surface of dental materials is exposed to various prophylaxis protocols during routine dental care. However, the impact of these protocols on the functional properties of the material’s surface remains unclear. This study investigates the influence of different dental prophylaxis protocols on the surface properties and their effect on the mechanical performance of CAD-CAM restorative materials. Discs (Ø = 15 mm, thickness = 1.2 mm) were fabricated from resin composite (RC, Tetric CAD), leucite-reinforced (LEU, IPS Empress CAD), lithium disilicate (LD, IPS e.max CAD), and zirconia ceramics (ZIR, IPS e.max ZirCAD MT). The materials were subjected to six prophylactic treatments: untreated (CTRL), prophylactic paste fine (PPF), prophylactic paste coarse (PPC), pumice stone (PS), air abrasion with sodium bicarbonate jet (BJ), and ultrasonic scaling (US). Biaxial flexural fatigue tests, along with fractographic, roughness, and topographic analyses, were conducted. No significant changes in fatigue strength were observed for RC, LD, and ZIR under any prophylaxis protocols. However, LEU subjected to BJ treatment exhibited significantly reduced fatigue strength (p = 0.004), with a 22% strength reduction compared to the monotonic test and substantial surface alterations. Surface roughness analyses revealed increased roughness for RC treated with PPF, PPC, and PS compared to CTRL (p < 0.05), while LD exhibited decreased roughness following PPF, PS, and US treatments (p < 0.05). In ZIR, only the BJ protocol increased roughness (p = 0.001). In conclusion, dental prophylaxis protocols do not significantly affect the mechanical strength of RC, LD, and ZIR materials, thus allowing any protocol to be used for these materials. However, for LEU ceramics, the BJ protocol should be avoided due to its effect of reducing fatigue strength and damaging the surface. Full article
(This article belongs to the Special Issue Surface Properties of Dental Materials and Instruments, 3rd Edition)
Show Figures

Figure 1

20 pages, 6177 KiB  
Article
Characterization of the Evolution with Temperature of the Structure and Properties of Geopolymer-Cordierite Composites
by Franklin Casarrubios, Alexandre Marlier, Charlotte Lang, Sandra Abdelouhab, Isabella Mastroianni, Geoffroy Bister and Maurice-François Gonon
Ceramics 2024, 7(4), 1513-1532; https://doi.org/10.3390/ceramics7040098 - 17 Oct 2024
Cited by 2 | Viewed by 1668
Abstract
This work is part of a research project aimed at producing ceramic-like materials, without the need for an initial sintering, for potential applications in catalysis or filtration at temperatures up to 1000 °C. In that context, cordierite-derived materials were prepared from recycled cordierite [...] Read more.
This work is part of a research project aimed at producing ceramic-like materials, without the need for an initial sintering, for potential applications in catalysis or filtration at temperatures up to 1000 °C. In that context, cordierite-derived materials were prepared from recycled cordierite powder (automotive industry waste) bonded with metakaolin-potassium silicate geopolymer. The principle is that these materials, prepared at temperatures below 100 °C, acquire their final properties during the high-temperature commissioning. The focus is on the influence of the K/Al ratio and cordierite fraction on the stability of the dimensions and porosity during heating at 1000 °C, and on the final Young’s modulus and coefficient of thermal expansion. Conventional and high-temperature XRD evidenced the absence of crystallization of the geopolymer binder and interaction with the cordierite filler during the heating stage when K/Al = 1 or 0.75. By contrast, crystallization of kalsilite and leucite, and diffusion of potassium ions in the structure of cordierite is evidenced for K/Al = 1.5 and 2.3. These differences strongly influence the shrinkage due to sintering and the final properties. It is shown that a K/Al ratio of 0.75 or 1 is favorable to the stability of the porosity, around 25 to 30%. Moreover, a low coefficient of thermal expansion of 4 to 4.5 × 10−6 K−1 and a Young’s modulus of 40 to 45 GPa is obtained. Full article
(This article belongs to the Special Issue Innovative Manufacturing Processes of Silicate Materials)
Show Figures

Figure 1

13 pages, 3441 KiB  
Article
Effect of TiO2 and CaO Addition on the Crystallization and Flexural Strength of Novel Leucite Glass-Ceramics
by Jamila Almuhamadi, Mustafa H. Almusali, Xiaohui Chen, Antonios L. Theocharopoulos, Hawraa F. Alostath, Natalia Karpukhina and Michael J. Cattell
Materials 2024, 17(14), 3422; https://doi.org/10.3390/ma17143422 - 11 Jul 2024
Cited by 3 | Viewed by 1262
Abstract
The aim of this study was to investigate the effects of TiO2/CaO addition on the crystallization and flexural strength of leucite glass-ceramics (GC). Synthesis of translucent and high strength GCs is important for the development of aesthetic and durable dental restorations. [...] Read more.
The aim of this study was to investigate the effects of TiO2/CaO addition on the crystallization and flexural strength of leucite glass-ceramics (GC). Synthesis of translucent and high strength GCs is important for the development of aesthetic and durable dental restorations. To achieve this, experimental aluminosilicate glasses (1–3 mol% TiO2 and CaO (B1, B2, B3)) were melted in a furnace to produce glasses. Glasses were ball milled, screened and heat treated via crystallization heat treatments, and characterized using XRD, differential scanning calorimetry, dilatometry, SEM and biaxial flexural strength (BFS). Increasing nucleation hold time (1–3 h) led to a reduction in crystallite number for B2 and B3 GC, and significant differences in leucite crystal size at differing nucleation holds within and across test groups (p < 0.05). A high area fraction of leucite crystals (55.1–60.8%) was found in the GC, with no matrix microcracking. Changes in the crystal morphology were found with higher TiO2/CaO addition. Mean BFS of the GC were 211.2–234.8 MPa, with significantly higher Weibull modulus (m = 18.9) for B3 GC. Novel glass compositions enriched with TiO2/CaO led to crystallization of leucite GC of high aspect ratio, with high BFS and reliability. The study’s findings suggest a potential high performance translucent leucite GC for use in the construction of dental restorations. Full article
(This article belongs to the Section Advanced and Functional Ceramics and Glasses)
Show Figures

Figure 1

20 pages, 7220 KiB  
Article
Soils on Recent Tephra of the Somma–Vesuvius Volcanic Complex, Italy
by Antonella Ermice and Carmine Amalfitano
Soil Syst. 2024, 8(2), 50; https://doi.org/10.3390/soilsystems8020050 - 30 Apr 2024
Viewed by 2286
Abstract
The Somma–Vesuvius volcanic complex emitted huge quantities of volcanic materials over a period from before 18,300 years BP to 1944. The activity during the last period, from post-AD 1631 to 1944, primarily produced lava and pyroclastics via effusive and strombolian eruptions. We investigated [...] Read more.
The Somma–Vesuvius volcanic complex emitted huge quantities of volcanic materials over a period from before 18,300 years BP to 1944. The activity during the last period, from post-AD 1631 to 1944, primarily produced lava and pyroclastics via effusive and strombolian eruptions. We investigated the pedogenesis on rocks formed from post-AD 1631 to 1944, occurring on the slopes of Mt. Vesuvius up to Gran Cono Vesuviano and in the northern valley separating Vesuvius from the older Mt. Somma edifice. Pertinent morphological, physical, chemical, and mineralogical (XRD and FT-IR) soil properties were studied. The results indicated the existence of thin and deep stratified soils on lava, as well as the presence of loose detritic covers formed via pyroclastic emplacement and redistribution. The soils showed minimal profile differentiation, frequently with layering recording the episodic addition of sediments. We found that the dominant coarse size of primary mineral particles was preserved, and there was a low level of clay production. The main mineralogical assemblage present in sands also persisted in clays, indicating the physical breaking of the parent material. Chemical weathering produced mineral modifications towards the active forms of Al and Fe and was also attested in selected soils by glass alteration, allophane production, and the presence of analcime in clay as a secondary product from leucite. The differences in glass alteration and analcime production found in the selected soils on lava were related to soil particle size and soil thickness. Concerning the youngest soil present on Gran Cono Vesuviano, other factors, such as the substratum’s age and site elevation, appeared to be implicated. Full article
Show Figures

Figure 1

17 pages, 7993 KiB  
Article
Advanced Solid Geopolymer Formulations for Refractory Applications
by Shaik Hussain, Sudhir Amritphale, John Matthews, Niloy Paul, Elizabeth Matthews and Richard Edwards
Materials 2024, 17(6), 1386; https://doi.org/10.3390/ma17061386 - 18 Mar 2024
Cited by 5 | Viewed by 2069
Abstract
Cement, as a construction material, has low thermal resistance, inherent fire resistance, and is incombustible up to a certain degree. However, the loss of its mechanical performance and spalling are its primary issues, and it thus cannot retain its performance in refractory applications. [...] Read more.
Cement, as a construction material, has low thermal resistance, inherent fire resistance, and is incombustible up to a certain degree. However, the loss of its mechanical performance and spalling are its primary issues, and it thus cannot retain its performance in refractory applications. The present study explores the performance of geopolymer formulations that have excellent fire resistance properties for potential refractory applications. This study is unique, as it investigates advanced solid geopolymer formulations that need only water to activate and bind. Various solid geopolymer formulations with fly ash as a precursor; potassium hydroxide and potassium silicate as activators; and mullite and alumina as refractory aggregates were studied for their compressive strength at up to 1100 °C and compared with their two-part conventional liquid alkaline geopolymer counterparts. Advanced solid geopolymer formulations with mullite and alumina as refractory aggregates had mechanical strength values of 84 MPa and 64 MPa post-1100 °C exposure and were further exposed to ten thermal cycles of 1100 °C to study their fatigue resistance and post-exposure compressive strengths. The geopolymer sample with mullite as a refractory aggregate yielded 115.2 MPa compressive strength after the fourth cycle of exposure. This sample was also studied for its temperature distribution upon direct flame exposure. All the geopolymer formulations displayed a drop in compressive strength at 600 °C due to viscous sintering and then a rise in strength at 1100 °C due to phase transformation. X-ray diffraction studies revealed that the formation of crystalline phases such as leucite, sanidine, and annite were responsible for the superior strengths at 1100 °C for the alumina- and mullite-based geopolymer formulations. Full article
(This article belongs to the Section Construction and Building Materials)
Show Figures

Figure 1

13 pages, 4833 KiB  
Article
Adhesive Performance of Resin Cement to Glass-Ceramic and Polymer-Based Ceramic CAD/CAM Materials after Applying Self-Etching Ceramic Primer or Different Surface Treatments
by Rana Turunç Oğuzman and Soner Şişmanoğlu
Materials 2024, 17(1), 2; https://doi.org/10.3390/ma17010002 - 19 Dec 2023
Cited by 4 | Viewed by 1773
Abstract
Ensuring optimum bond strength during cementation is vital for restoration success, with the practicality of the process being crucial in clinical practice. This study analyzed the effect of a single-step self-etching ceramic primer (MEP) and various surface treatments on the microshear bond strength [...] Read more.
Ensuring optimum bond strength during cementation is vital for restoration success, with the practicality of the process being crucial in clinical practice. This study analyzed the effect of a single-step self-etching ceramic primer (MEP) and various surface treatments on the microshear bond strength (µSBS) between resin cement and glass-ceramic or polymer-based ceramic CAD/CAM materials. Specimens were fabricated from leucite-based glass-ceramic (LEU), lithium disilicate glass-ceramic (LDC), resin nanoceramic (RNC), and polymer infiltrated ceramic network (PICN) (n = 160). They were then classified based on the surface treatments (n = 10): control (no treatment); sandblasting with Al2O3 (AL); etching with hydrofluoric acid (HF); and MEP application. Scanning electron microscopy was used to evaluate the surface topography. µSBS was measured after cementation and thermocycling procedures. Failure modes were examined with a stereomicroscope. Statistical analysis involved two-way analysis of variance and Tukey HSD tests with a significance level of 0.05. µSBS was significantly influenced by both surface treatment and CAD/CAM material type. The most enhanced µSBS values for each material, regarding the surface treatment, were: LEU and LDC, HF; RNC, AL; PICN, AL or HF. MEP significantly increased the µSBS values of CAD/CAM materials except RNC, yet it did not yield the highest µSBS values for any of them. Full article
(This article belongs to the Section Biomaterials)
Show Figures

Figure 1

43 pages, 23420 KiB  
Article
The Petrology and Geochemistry of REE-Enriched, Alkaline Volcanic Rocks of Ambitle Island, Feni Island Group, Papua New Guinea
by Olive L. Ponyalou, Michael G. Petterson and Joseph O. Espi
Geosciences 2023, 13(11), 339; https://doi.org/10.3390/geosciences13110339 - 6 Nov 2023
Cited by 2 | Viewed by 3477
Abstract
Ambitle in the Feni Island Group is located within the NW trending Tabar–Lihir–Tanga–Feni (TLTF) volcanic island chain, Melanesian Arc, northeastern Papua New Guinea. The TLTF chain is renowned for its alkaline magmatism, geothermal activity, copper–gold mineralization, and world-class gold mining. Although its geochemical [...] Read more.
Ambitle in the Feni Island Group is located within the NW trending Tabar–Lihir–Tanga–Feni (TLTF) volcanic island chain, Melanesian Arc, northeastern Papua New Guinea. The TLTF chain is renowned for its alkaline magmatism, geothermal activity, copper–gold mineralization, and world-class gold mining. Although its geochemical patterns indicate island arc signatures (i.e., high LILE and depleted HFSE), TLTF volcanism is not directly related to the older Melanesian Arc subduction system. However, it may have been influenced by source mantle metasomatism linked to the older subduction. The purpose of this study is to (1) present and interpret the petrographic, mineralogical, and geochemical data from Feni within the context of the tectonic evolution of the TLTF and (2) propose a geodynamic, petrogenetic model for the Feni volcanic rocks. The key methodologies used in this study are field mapping and sampling, petrographic analysis using the optical microscope, whole-rock geochemical analysis via XRF and ICP MS, and mineralogical analysis using an electron microprobe. The main rock types sampled in this study include feldspathoid-bearing basalt, trachybasalt, phonotephrite, trachyandesite, and trachydacite. Minerals identified include forsteritic olivine, diopside, augite, labradorite, andesine, anorthitic plagioclase, nepheline, and leucite in the primitive mafic suites, whereas the more evolved intermediate and felsic hypabyssal suites contain amphibole, albite, orthoclase, biotite, and either rare quartz or feldspathoids. Amphibole composition is primarily magnesiohastingsite with minor pargasite formed under polybaric conditions. Accessory minerals include apatite, titanite, and Ti-magnetite. We propose that limestone assimilation followed by fractional crystallization are plausible dominant processes in the geochemical evolution of the Ambitle volcanics. Clinopyroxene fractionation is dominant in the mafic volcanics whereas hornblende fractionation is a major petrologic process within the intermediate suites proven by the enrichment of LREE and depletions in MREE and HREE. Feni magmas are also highly enriched in REEs relative to neighboring arcs. This study is globally significant as alkaline magmas are important sources of Cu, Au, and REE as critical elements for green energy and modern technology. Full article
Show Figures

Figure 1

17 pages, 900 KiB  
Review
Survival Rates of Glass versus Hybrid Ceramics in Partial Prosthetic Restorations: A Scoping Review with Emphasis on Adhesive Protocols
by Manuela Manziuc, Alex Abbas Khechen, Marius Negucioiu, Irina Poiană, Andreea Kui, Anca Mesaroș and Smaranda Buduru
J. Clin. Med. 2023, 12(21), 6744; https://doi.org/10.3390/jcm12216744 - 25 Oct 2023
Cited by 4 | Viewed by 3437
Abstract
As dental practices and methodologies evolve, the emergence of novel materials adds complexity to clinical choices. While glass ceramics, particularly those based on lithium disilicate and leucite-reinforced variants, have been extensively researched and are well regarded for their attributes, hybrid ceramics remain relatively [...] Read more.
As dental practices and methodologies evolve, the emergence of novel materials adds complexity to clinical choices. While glass ceramics, particularly those based on lithium disilicate and leucite-reinforced variants, have been extensively researched and are well regarded for their attributes, hybrid ceramics remain relatively recent area of research that is less investigated. This review aims to evaluate the durability of glass and hybrid ceramics while assessing the role of various adhesive techniques on restoration longevity. Using a comprehensive search of PubMed and EMBASE, 84 articles from the past decade were found. Only eleven met the set criteria for analysis. The results underscore the urgent need for the extended monitoring of partial prosthetic restorations. The existing literature has significant gaps, hindering the attainment of dependable insights about these materials’ long-term performance. For a clearer understanding of how different ceramic systems affect restoration survival rates, rigorous research involving more participants and uniform outcome documentation is vital. Full article
Show Figures

Figure 1

12 pages, 1575 KiB  
Article
Evaluation of Fracture Resistance of Occlusal Veneers Made of Different Types of Materials Depending on Their Thickness
by Łukasz Czechowski, Beata Dejak, Bartłomiej Konieczny and Michał Krasowski
Materials 2023, 16(17), 6006; https://doi.org/10.3390/ma16176006 - 31 Aug 2023
Cited by 7 | Viewed by 3509
Abstract
Pathological tooth wear is an escalating social problem. Occlusal veneers can be an alternative to traditional prosthetic restorations such as crowns, inlays, and onlays. Background: The aim of this study is to assess the fracture resistance of occlusal veneers made of various materials [...] Read more.
Pathological tooth wear is an escalating social problem. Occlusal veneers can be an alternative to traditional prosthetic restorations such as crowns, inlays, and onlays. Background: The aim of this study is to assess the fracture resistance of occlusal veneers made of various materials depending on their thickness. Methods: In total, 120 occlusal veneers were examined. The restorations were made of four ceramics: leucite LC (IPS Empress Esthetic), hybrid HC (Vita Enamic), lithium disilicate LDC (IPS e.max Press), and zirconium oxide ZOC (Ceramill Zolid HT). A total of 30 veneers were made of each material, 10 for each of the three thicknesses: 1 mm, 1.5 mm, 2 mm. The restorations were cemented on identical abutments duplicated from the developed phantom tooth 35 (KaVo) with composite cement (All Bond Universal). The samples prepared in this way were subjected to a compressive strength test in a universal testing machine. Statistical analysis of the results was performed. Results: The average fracture resistance of occlusal veneers made of zirconium oxide ceramic was 1086–1640 N, of lithium disilicate ceramics 456–1044 N, of hybrid ceramics 449–576 N, and of leucite ceramics 257–499 N. Conclusions: Occlusal veneers made of ceramics, zirconium oxide and lithium disilicate, had the highest resistance to fractures. Restorations made of leucite ceramics turned out to be the least resistant to forces. The greater the thickness of the ceramic occlusal veneers, the greater their fracture resistance. Full article
Show Figures

Figure 1

13 pages, 7217 KiB  
Article
The Influence of Hydrofluoric Acid Temperature and Application Technique on Ceramic Surface Texture and Shear Bond Strength of an Adhesive Cement
by Cristiana Cuzic, Anca Jivanescu, Radu Marcel Negru, Iosif Hulka and Mihai Rominu
Materials 2023, 16(12), 4303; https://doi.org/10.3390/ma16124303 - 10 Jun 2023
Cited by 7 | Viewed by 1727
Abstract
All-ceramic restorations are the foundation of modern esthetic dentistry. Clinical approaches for preparation, durability, aesthetics, and repair have been reformed by the idea of adhesive dentistry. The aim of the study and the objective question was to evaluate the impact of heated hydrofluoric [...] Read more.
All-ceramic restorations are the foundation of modern esthetic dentistry. Clinical approaches for preparation, durability, aesthetics, and repair have been reformed by the idea of adhesive dentistry. The aim of the study and the objective question was to evaluate the impact of heated hydrofluoric acid pretreatment and the application technique’s influence on the surface morphology and roughness of leucite-reinforced glass–ceramic materials (IPS Empress CAD, Ivoclar Vivadent), which is fundamental for understanding the adhesive cementation process. Scanning electron microscopy was used to observe the effectiveness of the two HF (Yellow Porcelain Etch, Cerkamed) application techniques and the HF’s temperature impact on the surface topography of the ceramic. Based on surface conditioning methods, the adhesive cement (Panavia V5, Kuraray Noritake Dental Inc., Tokyo, Japan) was applied to the conditioned ceramic samples and light-cured. Shear bond strength values were correlated with the micro-retentive surface texture of the ceramic. With universal testing equipment at a 0.5 mm/min crosshead speed, SBS values between the resin cement and the ceramic material were assessed until failure. Analyzing the fractured surfaces of the specimens by digital microscopy, the failure modes were divided into three categories: adhesive, cohesive, and mixed failure. Analysis of variance (ANOVA) was used to statistically analyze the collected data. The results show that alternative treatment methods affected the material’s surface characteristics and have an influence on the shear bond strength. Full article
(This article belongs to the Special Issue From Conventional towards Modern Biomaterials in Dentistry)
Show Figures

Figure 1

11 pages, 1739 KiB  
Article
Ceramic versus Composite Resin Polishing Systems on the Surface Roughness of Milled Leucite-Reinforced Ceramics
by Carlos A. Jurado, Saad Alresayes, Silvia Rojas-Rueda, Ali Alqahtani, Akimasa Tsujimoto, Nicholas G. Fischer and Kelvin I. Afrashtehfar
Medicina 2023, 59(6), 1048; https://doi.org/10.3390/medicina59061048 - 29 May 2023
Cited by 3 | Viewed by 2400
Abstract
Background and Objective: This study aimed to compare the surface finish of milled leucite-reinforced ceramics polished with ceramic and composite polishing systems based on the manufacturers’ recommendations. Materials and Methods: Sixty subtractive computer-aided manufactured (s-CAM) leucite-reinforced glass-ceramic specimens (IPS-Empress-CAD) were assigned into six [...] Read more.
Background and Objective: This study aimed to compare the surface finish of milled leucite-reinforced ceramics polished with ceramic and composite polishing systems based on the manufacturers’ recommendations. Materials and Methods: Sixty subtractive computer-aided manufactured (s-CAM) leucite-reinforced glass-ceramic specimens (IPS-Empress-CAD) were assigned into six groups: no polishing, a ceramic polishing kit, and four composite kit groups. The roughness average (Ra) was evaluated in microns using a profilometer, and scanning electron micrographs were obtained for qualitative analysis. A Tukey HSD posthoc test (α = 0.05) was used to determine significant intergroup differences. Results: After surface evaluation of the ceramics, the Ra values of the polishing systems ranked OptraFine (0.41 ± 0.26) < Enhance (1.60 ± 0.54) < Shofu (2.14 ± 0.44) < Astropol (4.05 ± 0.72) < DiaComp (5.66 ± 0.62) < No Polishing (5.66 ± 0.74). Discussion: Composite polishing systems did not provide as smooth surfaces as the ceramic polishing kit for CAD-CAM leucite-reinforced ceramics. Thus, using ceramic polishing systems, polishing leucite ceramics is recommended, whereas composite polishing systems should not be considered as an alternative for use in minimally invasive dentistry. Full article
(This article belongs to the Special Issue Outcome of Minimally Invasive Techniques in Dentistry)
Show Figures

Figure 1

Back to TopTop