Sign in to use this feature.

Years

Between: -

Subjects

remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline

Journals

Article Types

Countries / Regions

Search Results (9)

Search Parameters:
Keywords = infrared tympanic thermometer

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
16 pages, 1285 KB  
Article
Different Correlation Patterns Between Circulating Amino Acids and Body Temperature in Fibromyalgia Syndrome: A Cross-Sectional Study
by Antonio Casas-Barragán, Francisco Molina, Rosa María Tapia-Haro, José Manuel Martínez-Martos, María Jesús Ramírez-Expósito, Alma Rus, María Correa-Rodríguez and María Encarnación Aguilar-Ferrándiz
Int. J. Mol. Sci. 2024, 25(24), 13517; https://doi.org/10.3390/ijms252413517 - 17 Dec 2024
Cited by 3 | Viewed by 2938
Abstract
The aim of this study was to analyze the association between circulating amino acids and central and peripheral body temperature in subjects with and without fibromyalgia syndrome (FMS). A total of 47 patients with FMS and 59 healthy subjects were included in the [...] Read more.
The aim of this study was to analyze the association between circulating amino acids and central and peripheral body temperature in subjects with and without fibromyalgia syndrome (FMS). A total of 47 patients with FMS and 59 healthy subjects were included in the study. The concentration of amino acids was determined in serum samples using a fluorimeter coupled with a high-performance liquid chromatography system. An infrared thermography camera was used to estimate peripheral hand temperatures. The core temperature of the body was estimated using an infrared thermometer, which was applied to the axillary and tympanic areas. Correlations between several thermographic variables of the hands and tryptophan, methionine, 3-methylhistidine, histidine, glutamic acid, and tyrosine were identified exclusively within the FMS group. In contrast, correlations between aminoadipic acid and serine and thermographic variables were observed only in the healthy control group. The concentrations of asparagine and lysine correlated with thermographic variables in both groups. The essential amino acid leucine was found to correlate with axillary temperature in FMS patients. However, it should be noted that the observed associations between aminoadipic acid and tryptophan blood concentrations and axillary temperature were limited to the control group. Several correlations were identified between circulating amino acids and different body temperatures in both healthy controls and patients with FMS. However, the correlation pattern differs significantly between FMS patients and healthy controls. These findings suggest the possibility of a change in the function of several amino acids in the thermoregulatory process in patients with FMS. Full article
(This article belongs to the Special Issue Amino Acids and Related Compounds in Health and Disease)
Show Figures

Figure 1

15 pages, 1788 KB  
Article
Influence of Hospital Environmental Variables on Thermometric Measurements and Level of Concordance: A Cross-Sectional Descriptive Study
by Candelaria de la Merced Díaz-González, Noa Mateos-López, Milagros De la Rosa-Hormiga and Gloria Carballo-Hernández
Int. J. Environ. Res. Public Health 2023, 20(5), 4665; https://doi.org/10.3390/ijerph20054665 - 6 Mar 2023
Cited by 2 | Viewed by 2488
Abstract
During a pandemic, and given the need to quickly screen febrile and non-febrile humans, it is necessary to know the concordance between different thermometers (TMs) and understand how environmental factors influence the measurements made by these instruments. Objective: The objective of this study [...] Read more.
During a pandemic, and given the need to quickly screen febrile and non-febrile humans, it is necessary to know the concordance between different thermometers (TMs) and understand how environmental factors influence the measurements made by these instruments. Objective: The objective of this study is to identify the potential influence of environmental factors on the measurements made by four different TMs and the concordance between these instruments in a hospital setting. Method: The study employed a cross-sectional observational methodology. The participants were patients who had been hospitalised in the traumatology unit. The variables were body temperature, room temperature, room relative humidity, light, and noise. The instruments used were a Non Contract Infrared TM, Axillary Electronic TM, Gallium TM, and Tympanic TM. A lux meter, a sound level meter, and a thermohygrometer measured the ambient variables. Results: The study sample included 288 participants. Weak significant relationships were found between noise and body temperature measured with Tympanic Infrared TM, r = −0.146 (p < 0.01) and likewise between environmental temperature and this same TM, r = 0.133 (p < 0.05). The concordance between the measurements made by the four different TMs showed an Intraclass Correlation Coefficient (ICC) of 0.479. Conclusions: The concordance between the four TMs was considered “fair”. Full article
(This article belongs to the Section Nursing)
Show Figures

Figure 1

12 pages, 810 KB  
Article
Clinical Accuracy of Non-Contact Forehead Infrared Thermometer Measurement in Children: An Observational Study
by Yeon-Mi Kim, Myung-Roul Jang, Ju-Ryoung Moon, Goeun Park, Ye-Jin An and Jeong-Meen Seo
Children 2022, 9(9), 1389; https://doi.org/10.3390/children9091389 - 14 Sep 2022
Cited by 10 | Viewed by 12863
Abstract
We evaluated the clinical reliability and utility of temperature measurements using no-contact forehead infrared thermometers (NCFITs) by comparing their temperature measurements with those obtained using infrared tympanic thermometers (IRTTs) in children. In this observational, prospective, and cross-sectional study, we enrolled 255 children (aged [...] Read more.
We evaluated the clinical reliability and utility of temperature measurements using no-contact forehead infrared thermometers (NCFITs) by comparing their temperature measurements with those obtained using infrared tympanic thermometers (IRTTs) in children. In this observational, prospective, and cross-sectional study, we enrolled 255 children (aged 1 month to 18 years) from the pediatric surgery ward at a tertiary medical center in Korea. The mean age of the children was 9.05 ± 5.39 years, and 54.9% were boys. The incidence rate of fever, defined as an IRTT reading of ≥38.0 °C, was 15.7%. The ICC coefficient for the assessment of agreement between temperatures recorded by the NCFIT and IRTT was 0.87, and the κ-coefficient was 0.83. The bias and 95% limits of agreement were 0.15 °C (−0.43 to 0.73). For an accurate diagnosis of fever (≥38 °C), the false-negative rate was much lower, but the false-positive rate was higher, especially in 6-year-old children. Therefore, NCFITs can be used to screen children for fever. However, a secondary check is required using another thermometer when the child’s temperature is >38 °C. NCFITs are proposed for screening but not for measuring the temperature. For the latter, an accurate and reliable thermometer shall be used. Full article
Show Figures

Figure 1

10 pages, 713 KB  
Article
A Novel Non-Invasive Thermometer for Continuous Core Body Temperature: Comparison with Tympanic Temperature in an Acute Stroke Clinical Setting
by Miloš Ajčević, Alex Buoite Stella, Giovanni Furlanis, Paola Caruso, Marcello Naccarato, Agostino Accardo and Paolo Manganotti
Sensors 2022, 22(13), 4760; https://doi.org/10.3390/s22134760 - 23 Jun 2022
Cited by 31 | Viewed by 8607
Abstract
There is a growing research interest in wireless non-invasive solutions for core temperature estimation and their application in clinical settings. This study aimed to investigate the use of a novel wireless non-invasive heat flux-based thermometer in acute stroke patients admitted to a stroke [...] Read more.
There is a growing research interest in wireless non-invasive solutions for core temperature estimation and their application in clinical settings. This study aimed to investigate the use of a novel wireless non-invasive heat flux-based thermometer in acute stroke patients admitted to a stroke unit and compare the measurements with the currently used infrared (IR) tympanic temperature readings. The study encompassed 30 acute ischemic stroke patients who underwent continuous measurement (Tcore) with the novel wearable non-invasive CORE device. Paired measurements of Tcore and tympanic temperature (Ttym) by using a standard IR-device were performed 3–5 times/day, yielding a total of 305 measurements. The predicted core temperatures (Tcore) were significantly correlated with Ttym (r = 0.89, p < 0.001). The comparison of the Tcore and Ttym measurements by Bland–Altman analysis showed a good agreement between them, with a low mean difference of 0.11 ± 0.34 °C, and no proportional bias was observed (B = −0.003, p = 0.923). The Tcore measurements correctly predicted the presence or absence of Ttym hyperthermia or fever in 94.1% and 97.4% of cases, respectively. Temperature monitoring with a novel wireless non-invasive heat flux-based thermometer could be a reliable alternative to the Ttym method for assessing core temperature in acute ischemic stroke patients. Full article
(This article belongs to the Section Biomedical Sensors)
Show Figures

Figure 1

15 pages, 2240 KB  
Article
Studying the Accuracy and Function of Different Thermometry Techniques for Measuring Body Temperature
by Aaron James Mah, Leili Ghazi Zadeh, Mahta Khoshnam Tehrani, Shahbaz Askari, Amir H. Gandjbakhche and Babak Shadgan
Biology 2021, 10(12), 1327; https://doi.org/10.3390/biology10121327 - 15 Dec 2021
Cited by 30 | Viewed by 19967
Abstract
The purpose of this study was to determine which thermometry technique is the most accurate for regular measurement of body temperature. We compared seven different commercially available thermometers with a gold standard medical-grade thermometer (Welch-Allyn): four digital infrared thermometers (Wellworks, Braun, Withings, MOBI), [...] Read more.
The purpose of this study was to determine which thermometry technique is the most accurate for regular measurement of body temperature. We compared seven different commercially available thermometers with a gold standard medical-grade thermometer (Welch-Allyn): four digital infrared thermometers (Wellworks, Braun, Withings, MOBI), one digital sublingual thermometer (Braun), one zero heat flux thermometer (3M), and one infrared thermal imaging camera (FLIR One). Thirty young healthy adults participated in an experiment that altered core body temperature. After baseline measurements, participants placed their feet in a cold-water bath while consuming cold water for 30 min. Subsequently, feet were removed and covered with a blanket for 30 min. Throughout the session, temperature was recorded every 10 min with all devices. The Braun tympanic thermometer (left ear) had the best agreement with the gold standard (mean error: 0.044 °C). The FLIR One thermal imaging camera was the least accurate device (mean error: −0.522 °C). A sign test demonstrated that all thermometry devices were significantly different than the gold standard except for the Braun tympanic thermometer (left ear). Our study showed that not all temperature monitoring techniques are equal, and suggested that tympanic thermometers are the most accurate commercially available system for the regular measurement of body temperature. Full article
(This article belongs to the Special Issue Miniaturized Biosensors and Wearable Devices)
Show Figures

Figure 1

15 pages, 2027 KB  
Article
Suitability of Different Thermometers for Measuring Body Core and Skin Temperatures in Suckling Piglets
by Simone M. Schmid, Wolfgang Büscher and Julia Steinhoff-Wagner
Animals 2021, 11(4), 1004; https://doi.org/10.3390/ani11041004 - 2 Apr 2021
Cited by 16 | Viewed by 3962
Abstract
Monitoring the temperature of piglets after birth is critical to ensure their well-being. Rectal temperature measurement is time-consuming, requires fixation of the animal and is stressful for piglets. This study aims to evaluate the effectiveness of infrared thermometry and thermography as compared to [...] Read more.
Monitoring the temperature of piglets after birth is critical to ensure their well-being. Rectal temperature measurement is time-consuming, requires fixation of the animal and is stressful for piglets. This study aims to evaluate the effectiveness of infrared thermometry and thermography as compared to rectal temperatures. We investigated digital thermometers for rectal measurements, infrared ear thermometers, infrared forehead thermometers, infrared laser thermometers and an infrared camera during field trials with piglets aged 1–13 days. Temperatures differed between the left and right ear and ear base (p < 0.01), but not between temples. Three forehead and laser devices yielded different temperatures (p < 0.01). Temperatures assessed with a laser thermometer decreased with distance from the target (p < 0.01). The highest correlation observed was between the rectal and tympanic temperatures (r = 0.89; p < 0.01). For temperatures assessed with the camera, inner thigh and abdomen correlated most closely to core temperature (0.60 ≤ r ≤ 0.62; p < 0.01). Results indicate that infrared ear thermometry commonly used in humans is also suited for assessing temperature in piglets. The inner thigh and abdomen seem promising locations for estimating core temperature with an infrared camera, but this approach needs to be adapted to reduce time exposure and stress for the piglets to be used under practical conditions. Full article
(This article belongs to the Section Animal Welfare)
Show Figures

Figure 1

17 pages, 1374 KB  
Article
Investigation of the Impact of Infrared Sensors on Core Body Temperature Monitoring by Comparing Measurement Sites
by Hsuan-Yu Chen, Andrew Chen and Chiachung Chen
Sensors 2020, 20(10), 2885; https://doi.org/10.3390/s20102885 - 19 May 2020
Cited by 116 | Viewed by 22011
Abstract
Many types of thermometers have been developed to measure body temperature. Infrared thermometers (IRT) are fast, convenient and ease to use. Two types of infrared thermometers are uses to measure body temperature: tympanic and forehead. With the spread of COVID-19 coronavirus, forehead temperature [...] Read more.
Many types of thermometers have been developed to measure body temperature. Infrared thermometers (IRT) are fast, convenient and ease to use. Two types of infrared thermometers are uses to measure body temperature: tympanic and forehead. With the spread of COVID-19 coronavirus, forehead temperature measurement is used widely to screen people for the illness. The performance of this type of device and the criteria for screening are worth studying. This study evaluated the performance of two types of tympanic infrared thermometers and an industrial infrared thermometer. The results showed that these infrared thermometers provide good precision. A fixed offset between tympanic and forehead temperature were found. The measurement values for wrist temperature show significant offsets with the tympanic temperature and cannot be used to screen fevers. The standard operating procedure (SOP) for the measurement of body temperature using an infrared thermometer was proposed. The suggestion threshold for the forehead temperature is 36 °C for screening of fever. The body temperature of a person who is possibly ill is then measured using a tympanic infrared thermometer for the purpose of a double check. Full article
(This article belongs to the Section Physical Sensors)
Show Figures

Figure 1

8 pages, 2399 KB  
Article
Measurement of Core Body Temperature Using Graphene-Inked Infrared Thermopile Sensor
by Jorge S. Chaglla E., Numan Celik and Wamadeva Balachandran
Sensors 2018, 18(10), 3315; https://doi.org/10.3390/s18103315 - 3 Oct 2018
Cited by 51 | Viewed by 8701
Abstract
Continuous and reliable measurements of core body temperature (CBT) are vital for studies on human thermoregulation. Because tympanic membrane directly reflects the temperature of the carotid artery, it is an accurate and non-invasive method to record CBT. However, commercial tympanic thermometers lack portability [...] Read more.
Continuous and reliable measurements of core body temperature (CBT) are vital for studies on human thermoregulation. Because tympanic membrane directly reflects the temperature of the carotid artery, it is an accurate and non-invasive method to record CBT. However, commercial tympanic thermometers lack portability and continuous measurements. In this study, graphene inks were utilized to increase the accuracy of the temperature measurements from the ear by coating graphene platelets on the lens of an infrared thermopile sensor. The proposed ear-based device was designed by investigating ear canal geometry and developed with 3D printing technology using the Computer-Aided Design (CAD) Software, SolidWorks 2016. It employs an Arduino Pro Mini and a Bluetooth module. The proposed system runs with a 3.7 V, 850 mAh rechargeable lithium-polymer battery that allows long-term, continuous monitoring. Raw data are continuously and wirelessly plotted on a mobile phone app. The test was performed on 10 subjects under resting and exercising in a total period of 25 min. Achieved results were compared with the commercially available Braun Thermoscan, Original Thermopile, and Cosinuss One ear thermometers. It is also comprehended that such system will be useful in personalized medicine as wearable in-ear device with wireless connectivity. Full article
(This article belongs to the Special Issue Nanostructured Surfaces in Sensing Systems)
Show Figures

Figure 1

17 pages, 260 KB  
Article
Evaluation of Performance and Uncertainty of Infrared Tympanic Thermometers
by Wenbin Chung and Chiachung Chen
Sensors 2010, 10(4), 3073-3089; https://doi.org/10.3390/s100403073 - 31 Mar 2010
Cited by 19 | Viewed by 13457
Abstract
Infrared tympanic thermometers (ITTs) are easy to use and have a quick response time. They are widely used for temperature measurement of the human body. The accuracy and uncertainty of measurement is the importance performance indicator for these meters. The performance of two [...] Read more.
Infrared tympanic thermometers (ITTs) are easy to use and have a quick response time. They are widely used for temperature measurement of the human body. The accuracy and uncertainty of measurement is the importance performance indicator for these meters. The performance of two infrared tympanic thermometers, Braun THT-3020 and OMRON MC-510, were evaluated in this study. The cell of a temperature calibrator was modified to serve as the standard temperature of the blackbody. The errors of measurement for the two meters were reduced by the calibration equation. The predictive values could meet the requirements of the ASTM standard. The sources of uncertainty include the standard deviations of replication at fixed temperature or the predicted values of calibration equation, reference standard values and resolution. The uncertainty analysis shows that the uncertainty of calibration equation is the main source for combined uncertainty. Ambient temperature did not have the significant effects on the measured performance. The calibration equations could improve the accuracy of ITTs. However, these equations did not improve the uncertainty of ITTs. Full article
Show Figures

Back to TopTop