Sign in to use this feature.

Years

Between: -

Subjects

remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline

Journals

remove_circle_outline
remove_circle_outline
remove_circle_outline

Article Types

Countries / Regions

Search Results (216)

Search Parameters:
Keywords = hot jet

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
29 pages, 4915 KB  
Article
Gas–Solid Interaction Mechanisms in Bulk Material Discharge Through Horizontal Orifices: Arch Stability and Flow Regime Transitions
by Saule Kazhikenova and Sandugash Akhmetova
Processes 2026, 14(13), 2169; https://doi.org/10.3390/pr14132169 - 3 Jul 2026
Cited by 1 | Viewed by 379
Abstract
Reliable discharge of bulk granular materials is essential for the efficient operation of shaft furnaces, pneumatic conveying systems, and industrial dosing equipment, where uncontrolled arch formation can lead to flow instability and blockage. This study investigates the effect of gas velocity, direction, and [...] Read more.
Reliable discharge of bulk granular materials is essential for the efficient operation of shaft furnaces, pneumatic conveying systems, and industrial dosing equipment, where uncontrolled arch formation can lead to flow instability and blockage. This study investigates the effect of gas velocity, direction, and configuration on arch formation and collapse during bulk granular material discharge through horizontal orifices. Experiments were conducted using cold quasi-2D (250 × 50 × 5 mm) and hot scale models (cylindrical shaft, D = 300 mm, H = 500 mm) with high-speed imaging (2000 fps, 1280 × 1024) across various materials. Uniform gas flow stabilizes arches, reducing the normalized mass flow rate Wt/W0 to 0.20 ± 0.03 at critical gas velocity ratios V1/V220 and area ratios L1/L20.37. Conversely, localized gas jets increase Wt/W0 to 1.45 ± 0.05. The scientific novelty lies in the development of a unified torque-balance model that, for the first time, predicts critical counter-current gas velocities Vkr across different operating configurations with an error not exceeding ±28.9% (n = 3, p < 0.05). Three characteristic discharge regimes—continuous flow, pulsating discharge, and blockage-dominated flow—were identified and related to the stability of dynamically unstable arch structures. These findings provide a quantitative basis for the design and optimization of industrial systems such as shaft furnaces, pneumatic conveyors, and dosing units. Future work will focus on industrial-scale validation, extension to humid or cohesive materials, and investigation of more complex flow geometries to further improve gas-assisted flow control. Full article
(This article belongs to the Section Particle Processes)
Show Figures

Figure 1

22 pages, 7512 KB  
Article
Frequency-Domain Proper Orthogonal Decomposition for Asynchronously Sampled Unsteady Flow Fields
by Chen Xu, Yang Yang, Xiaojiang Gu and Yijun Mao
Modelling 2026, 7(4), 126; https://doi.org/10.3390/modelling7040126 - 25 Jun 2026
Viewed by 293
Abstract
The snapshot proper orthogonal decomposition (POD) method relies on synchronously sampled datasets, significantly limiting its utility for analyzing asynchronous measurements in unsteady flow studies. This paper proposes a frequency-domain proper orthogonal decomposition (FDPOD) method tailored for mode extraction and flow field reconstruction from [...] Read more.
The snapshot proper orthogonal decomposition (POD) method relies on synchronously sampled datasets, significantly limiting its utility for analyzing asynchronous measurements in unsteady flow studies. This paper proposes a frequency-domain proper orthogonal decomposition (FDPOD) method tailored for mode extraction and flow field reconstruction from asynchronously sampled data. The FDPOD framework integrates three key components: frequency-domain transformation to decouple phase discrepancies inherent in asynchronous sampling, power spectral density (PSD) analysis combined with segmented ensemble averaging to suppress spectral leakage errors, and eigenvalue decomposition of energy-ranked frequency components to identify dominant coherent structures. Validated through numerical simulations of a subsonic jet and experimental measurements from a low-speed mixed-flow fan, the method demonstrates exceptional performance under asynchronous conditions: cumulative energy errors are reduced to 0.3% across the first 50 modes, while flow field reconstruction achieves 99.5% accuracy. Dominant mode structures exhibit remarkable consistency with those derived from synchronous conditions, with hot-wire measurement errors remaining below 0.03% for both asynchronous and temporally shuffled datasets. These results position FDPOD as a robust and practical tool for analyzing complex unsteady flows where synchronous data acquisition proves impractical, particularly in large-scale or spatially distributed measurement systems. Full article
(This article belongs to the Section Modelling in Mechanics)
Show Figures

Figure 1

31 pages, 3305 KB  
Article
A Synchronized Spin Model for Black-Hole Accretion Systems
by Masahiro Morikawa and Akika Nakamichi
Entropy 2026, 28(6), 663; https://doi.org/10.3390/e28060663 - 10 Jun 2026
Viewed by 422
Abstract
Black-hole accretion systems exhibit a characteristic coexistence of activities: broad-band X-ray variability, hot coronae, wide-angle winds, and both steady and discrete jets. This coexistence suggests a persistently time-dependent magnetic background in which noisy fluctuations and explosive release are both essential. In this paper, [...] Read more.
Black-hole accretion systems exhibit a characteristic coexistence of activities: broad-band X-ray variability, hot coronae, wide-angle winds, and both steady and discrete jets. This coexistence suggests a persistently time-dependent magnetic background in which noisy fluctuations and explosive release are both essential. In this paper, we connect them all to the storage, organization, and intermittent reconnection-mediated release of magnetic energy, and we propose a Synchronized Spin Model (SSM) in which multiple local dynamos in a rotating accretion flow are represented as interacting macro-spins. Their synchronization, partial synchronization, excursion, and reversal define a compact set of collective variables that organize both timing statistics and large-scale morphology. In this picture, multiscale magnetic reconnection converts stored magnetic energy into coronal heating, flares, intermittent outflows, and discrete jet activity, while the same synchronization dynamics produce amplitude modulation and demodulation, providing a route to 1/f-like variability, rms–flux/Taylor-like scaling, and approximately log-normal statistics of the demodulated envelope. We further argue that, although the continuous flux distribution in black-hole systems is more naturally discussed in multiplicative or log-normal terms, broader event-catalog statistics remain useful for describing suitably defined burst hierarchies, particularly by analogy with solar and stellar flare systems. The hard/soft cycle of X-ray binaries is then interpreted as motion through magnetic state space. Full article
(This article belongs to the Section Astrophysics, Cosmology, and Black Holes)
Show Figures

Figure 1

20 pages, 5604 KB  
Article
Some Predictions on Behavior of the Nuclear Matter in Nuclear Collisions at FAIR-GSI Energies
by Nicolae George Țuțuraș, Alexandru Jipa, Dănuț Argintaru, Oana Ristea, Marius Călin, Cătălin Ristea, Ionel Lazanu, Tiberiu Eșanu, Adam Jinaru and Murat Ablai
Particles 2026, 9(2), 62; https://doi.org/10.3390/particles9020062 - 26 May 2026
Viewed by 738
Abstract
In order to describe the heavy ion collision dynamics which implies the formation of hot and very dense nuclear matter in the overlapping region of the two colliding nuclei, we used simulated numerical calculations for FAIR available energies. We used the anti- [...] Read more.
In order to describe the heavy ion collision dynamics which implies the formation of hot and very dense nuclear matter in the overlapping region of the two colliding nuclei, we used simulated numerical calculations for FAIR available energies. We used the anti-kT jet-detection algorithm for highlighting the main directions of flow in Au-Au collisions at CBM energies, thus obtaining structures of the events depending on the number of flow streams. The jet-finder algorithm identified domains in the y-ψ (rapidity-azimuthal angle) plane, where the number of charged particles, momenta and energy take higher values compared to other areas of this plane. The anisotropic flow coefficients vn may offer information about the pressure gradients in the early stages of the collision and about the high-density nuclear matter properties. The observation of K+ mesons in heavy ion collisions is of interest since K+ mesons, due to their strangeness, have a mean free path that exceeds the dimensions of the “fireball”. In the numerical calculations the interval of rapidity 0<y<0.8 is highlighted, for which the fluctuations of the antiparticle to particle ratio excitation functions show non-monotonic behavior in the 10–13 A GeV energy interval. Full article
(This article belongs to the Section Nuclear and Hadronic Theory)
Show Figures

Figure 1

21 pages, 12380 KB  
Article
Experimental Investigations into the Failure Modes of Different Formats of Lithium-Ion Cells and the Potential Impact on Building Materials
by Jason Gill, Jonathan E. H. Buston, Gemma E. Howard, Steven L. Goddard, Philip A. P. Reeve and Jack W. Mellor
Fire 2026, 9(6), 213; https://doi.org/10.3390/fire9060213 - 22 May 2026
Viewed by 614
Abstract
Lithium-ion battery (LIB) cells are available in various sizes, formats, and chemistries. Should a LIB be exposed to conditions outside its operating parameters, each variation affects the cell failure mechanisms and any resultant fire dynamic. Battery fires can be dynamic events that differ [...] Read more.
Lithium-ion battery (LIB) cells are available in various sizes, formats, and chemistries. Should a LIB be exposed to conditions outside its operating parameters, each variation affects the cell failure mechanisms and any resultant fire dynamic. Battery fires can be dynamic events that differ significantly from those solid-, liquid- or gas-based fire curves often used in standard building material fire resistance tests. This preliminary research aimed to investigate how standard building materials, sometimes used as a compartment fire envelope, such as gypsum plasterboard, react when exposed to a dynamic battery fire. The research explored batteries that produced jet fires, could act as projectiles, or produced overpressures when they failed. The results showed that cylindrical cells can travel at significant speeds and distances due to expulsing the cell’s contents through the cell’s vent or ejected end cap. These cells were shown to be capable of piercing plasterboard and remain hot enough to present a fire risk where they fall on the far side of the plasterboard. It was also found that the overpressures produced by failing prismatic cells affected the structural integrity of some building materials. The results show a need for further research into the effectiveness of standard building fire controls when exposed to LIB fires. Full article
(This article belongs to the Special Issue Fire and Explosion Hazards in Energy Systems)
Show Figures

Figure 1

16 pages, 16681 KB  
Article
Study on Fire-Controlling Blanket and Castable Fire-Extinguishing Agent
by Langlang Liu, Zhilong Wei, Haisheng Zhen, Wenwen Wang and Yang Wu
Fire 2026, 9(5), 185; https://doi.org/10.3390/fire9050185 - 30 Apr 2026
Viewed by 2323
Abstract
This paper conducts an experimental study to develop a response strategy for lithium-ion battery fires. Guided by the principle of “first control, then extinguish”, the strategy integrates a lithium-ion battery-specific fire-controlling blanket with castable fire-extinguishing agents. Both fire tests of e-bikes and lithium-ion [...] Read more.
This paper conducts an experimental study to develop a response strategy for lithium-ion battery fires. Guided by the principle of “first control, then extinguish”, the strategy integrates a lithium-ion battery-specific fire-controlling blanket with castable fire-extinguishing agents. Both fire tests of e-bikes and lithium-ion batteries are conducted. From e-bike fire tests, the feasibility of rescuers conducting close-range disposal of LIB (lithium-ion battery) fires is analyzed from three perspectives, i.e., fire evolution stage, battery splashing and high temperature. The results indicate a high risk of fire spread, as well as a strong likelihood of human injury caused by flying LIB debris and extremely hot gases. Subsequently, the fire-controlling capability of the fire blanket is validated. It not only blocks splashing batteries and jet flames, reducing combustion intensity, but also offers a safe way for personnel to operate the portable fire extinguishers. Through two castable extinguishing agents tested, the perfluorohexanone-based agent outperforms the water-based alternative. The reasons are as follows. First, perfluorohexanone evaporates easily in the low-temperature, confined environment created by the fire blanket. Second, it possesses both physical and chemical fire-extinguishing capabilities, ultimately delivering a more potent combustion suppression effect. Full article
Show Figures

Figure 1

15 pages, 5191 KB  
Article
Coupling 3D CFD of Air Knife Jets with an Analytical Model for Coating Thickness Prediction and Operating Window Definition in Hot-Dip Galvanizing
by Hao Liu, Lisong Zhu, Muyuan Zhou, Daiyan Zhao, Di Pan, Haibo Xie, Jian Han, Hongwei Cao, Li Sun, Hongqiang Liu, Xi Wu, Tieling Zhang and Zhengyi Jiang
Eng 2026, 7(5), 206; https://doi.org/10.3390/eng7050206 - 29 Apr 2026
Viewed by 876
Abstract
A coupled modeling framework is developed to predict coating thickness after air knife wiping in hot-dip galvanizing. A 3D large eddy simulation (LES) using the WALE sub-grid scale (SGS) model is performed to resolve the jet impingement on the moving strip. Time-averaged wall [...] Read more.
A coupled modeling framework is developed to predict coating thickness after air knife wiping in hot-dip galvanizing. A 3D large eddy simulation (LES) using the WALE sub-grid scale (SGS) model is performed to resolve the jet impingement on the moving strip. Time-averaged wall static pressure pωy and wall shear stress τωy along the strip direction are extracted and used as driving inputs for a thin film model. Starting from the continuity and momentum equations, a lubrication-type formulation is derived, leading to a local cubic equation for film thickness h(y) that accounts for both pressure gradient and gravity. A coupling workflow is established to preprocess the LES wall signals and compute the final coating thickness hfinal. Parametric sweeps of inlet total pressure P0 and the knife-to-strip distance H are employed to construct operating window maps. The predicted trends show that increasing P0 or decreasing H intensifies wall loading and reduces hfinal, while the operating window boundary is governed by the balance between the gas-induced shears. Representative results, including peak wall loading and thickness ranges, are reported for industrially relevant operating conditions. Full article
(This article belongs to the Section Materials Engineering)
Show Figures

Figure 1

35 pages, 5834 KB  
Article
Recovery and Utilization of Flash Steam from Rotary Desiccant Regeneration in Dry Room HVAC Systems
by Kyu Hwa Jung and Young Il Kim
Energies 2026, 19(9), 2127; https://doi.org/10.3390/en19092127 - 28 Apr 2026
Viewed by 489
Abstract
Dry rooms used in battery and semiconductor research facilities require ultra-low dew-point environments, which demand significant thermal energy for desiccant rotor regeneration. In steam-regenerated systems, condensate discharged through steam traps partially evaporates due to pressure reduction, generating flash steam that is typically released [...] Read more.
Dry rooms used in battery and semiconductor research facilities require ultra-low dew-point environments, which demand significant thermal energy for desiccant rotor regeneration. In steam-regenerated systems, condensate discharged through steam traps partially evaporates due to pressure reduction, generating flash steam that is typically released into the atmosphere, resulting in substantial energy losses. This study investigates the generation and recovery potential of flash steam in dry room HVAC systems. Field measurements were conducted for 18 steam-regenerated desiccant air handling units installed in a medium-scale research facility (total floor area: 43,000 m2) in southern Gyeonggi Province, Korea. Boiler operation data—including feedwater flow rate, pressure, and operating time—were analyzed over a six-month period from March to August 2025. The results showed that the average flash steam generation rate was approximately 1.16 ton/h, corresponding to 8.56% of the average feedwater flow rate. Two recovery methods were evaluated: a steam jet thermocompressor (SJT) and an exhaust vapor condenser (EVC). The analysis revealed that the EVC system provides a more practical solution for medium-scale dry rooms because it does not require high-pressure primary steam. By recovering flash steam using three EVC units, an average heat recovery of 724 kW was achieved. The recovered heat can produce 86 °C hot water, which can be utilized as a driving heat source for an absorption chiller, generating approximately 507 kW of cooling capacity. This configuration partially offsets the cooling load of existing centrifugal chillers, thereby reducing electrical energy consumption. In addition, the proposed system eliminates atmospheric discharge of flash steam, mitigating the visible white plume phenomenon commonly observed in industrial facilities. The results demonstrate the technical feasibility of integrating flash steam recovery with absorption cooling to enhance energy efficiency in medium-scale dry room HVAC systems. Full article
(This article belongs to the Section B: Energy and Environment)
Show Figures

Figure 1

12 pages, 1913 KB  
Article
Femtosecond Laser-Induced Ultrafast Electron Redistribution near a Microscale Metallic Filament
by Dacai Liu and Bin Li
Photonics 2026, 13(5), 415; https://doi.org/10.3390/photonics13050415 - 24 Apr 2026
Viewed by 712
Abstract
In this study, a femtosecond laser beam is delivered to metal wire targets to generate suprathermal electron jets reaching energies of several hundreds of keV. During the process, it is observed that the mirror-imaging distribution of the beam focus with respect to the [...] Read more.
In this study, a femtosecond laser beam is delivered to metal wire targets to generate suprathermal electron jets reaching energies of several hundreds of keV. During the process, it is observed that the mirror-imaging distribution of the beam focus with respect to the surface of the target displays highly asymmetric features and different dynamic responses. Especially, the exterior focus exhibits an extraordinary polarity reversal of the macroscopic current, while the interior focus behaves ordinarily. The former is attributed to the strong field at the focal point outside the surface, causing the secondary ionization and driving electrons back to the target, thereby reshaping the distribution of these high-energy hot electrons and the morphology of plasma jets. A numerical model is proposed to simulate the experimental observation and interpret the unexpected phenomenon. Furthermore, the particle-in-cell algorithm is also implemented to verify the results and present more details. This study seeks to emphasize the role of focal position in regulating the photoemission process, which may offer a fresh perspective for research in laser–material interactions and dynamics. Full article
Show Figures

Figure 1

26 pages, 4224 KB  
Article
Experimental Study of Air Curtain Smoke Confinement and Vehicle Obstruction Effects in a Modular Scaled Tunnel Model
by MuYuan Hsu, RyhNan Pan, LiYu Tseng, ShiuanCheng Wang, PoWen Huang, ChiJi Lin and ChungHwei Su
Fire 2026, 9(4), 162; https://doi.org/10.3390/fire9040162 - 12 Apr 2026
Viewed by 816
Abstract
Air curtain systems have been proposed as a supplementary smoke control strategy for vehicle tunnels, particularly where structural constraints limit the installation or upgrading of conventional ventilation systems. However, most previous studies rely on numerical simulations or fixed experimental facilities, while flexible experimental [...] Read more.
Air curtain systems have been proposed as a supplementary smoke control strategy for vehicle tunnels, particularly where structural constraints limit the installation or upgrading of conventional ventilation systems. However, most previous studies rely on numerical simulations or fixed experimental facilities, while flexible experimental platforms and the influence of vehicle obstruction on smoke behavior remain less explored. This study experimentally investigates the smoke confinement performance of an air curtain using a 1:18 modular detachable scaled vehicle tunnel model. The modular configuration enables flexible assembly and adjustment of the experimental setup for different test conditions. A series of laboratory experiments was conducted using a liquefied petroleum gas (LPG) burner to simulate a vehicle fire. Temperature measurements and smoke visualization were performed under different air curtain jet velocities and vehicle obstruction conditions to analyze the interaction between the air curtain jet and buoyancy-driven smoke flow. The results show that the air curtain significantly restricts the upstream propagation of hot smoke and modifies the thermal field inside the tunnel. When the jet velocity reached approximately 5 m/s, the temperature in the protected region decreased by about 25–35% compared with the case without an air curtain. In addition, the presence of vehicle models altered the airflow structure and increased heat accumulation in the middle region of the tunnel cross-section. These results demonstrate that the proposed modular tunnel model provides a reliable experimental platform for tunnel fire research and highlights the importance of considering vehicle obstruction effects in tunnel smoke control studies. Full article
Show Figures

Figure 1

23 pages, 3719 KB  
Article
A Dual-Branch Feature Construction for Hot Jet Remote Sensing of a Certain Aero-Engine Under Diverse Operating Conditions
by Zhenping Kang, Yuntao Li, Yurong Liao, Xinyan Yang and Zhaoming Li
Aerospace 2026, 13(4), 350; https://doi.org/10.3390/aerospace13040350 - 9 Apr 2026
Cited by 1 | Viewed by 436
Abstract
Aiming to address the problem of extracting the remote sensing FTIR spectral characteristics of the hot jet of a certain type of aero-engine under different working conditions, this paper proposes a feature construction algorithm for the remote sensing FTIR spectral characteristics of the [...] Read more.
Aiming to address the problem of extracting the remote sensing FTIR spectral characteristics of the hot jet of a certain type of aero-engine under different working conditions, this paper proposes a feature construction algorithm for the remote sensing FTIR spectral characteristics of the aero-engine hot jet based on the fusion of the original spectral features and the deep spectral features. The infrared spectrum was collected at a distance of 280 m, covering the spectral range of 2.5–15 μm with a resolution of 1 cm−1. The Neighborhood–Autoencoder Integration Dual-Branch Network (NAIDN) feature construction algorithm is proposed. This algorithm contains a neighborhood integration branch and an autoencoder branch. The neighborhood integration branch converts the radiation intensity values of discrete wavenumber points into local energy aggregation features through a sliding window, accurately extracting the key physical information in the original spectrum. The autoencoder branch uses a three-layer fully connected neural network architecture to mine the deep spectral features of the spectral data. The algorithms of the two branches not only retain the physical interpretability of spectral analysis but also capture the multi-parameter coupling information hidden in the hot jet spectrum through the representation learning ability of the autoencoder, achieving feature fusion across spatial dimensions. Compared with traditional feature construction algorithms, the dual-branch feature construction algorithm proposed in this paper has stronger comprehensive representation capabilities. The content of carbon dioxide (CO2) and cyanide groups (-C≡N) in the hot jet under different operating conditions varies significantly. In the experiment, an unsupervised clustering algorithm, the Agglomerative Clustering classifier, is selected, and the classification accuracy of the features extracted by the algorithm in this paper reaches 92.97% on this classifier, thereby verifying the effectiveness of the algorithm in this paper. Full article
(This article belongs to the Section Aeronautics)
Show Figures

Figure 1

18 pages, 3864 KB  
Article
Enhancement of Near-Field Heat Transfer Performance of a Piezoelectric Synthetic Jet with Outlet Flaps
by Xincai Liu, Yi Hu, Jincheng Hu, Wenjuan Liu, Yuhan Wang and Qi Liu
Micromachines 2026, 17(4), 440; https://doi.org/10.3390/mi17040440 - 1 Apr 2026
Viewed by 606
Abstract
This study experimentally investigates a compact side-exhaust piezoelectric synthetic jet actuator equipped with outlet flaps and compares its performance with a flap-free baseline design. The flap concept is intended to mitigate hot-air recirculation during the suction phase and thereby improve near-field cooling in [...] Read more.
This study experimentally investigates a compact side-exhaust piezoelectric synthetic jet actuator equipped with outlet flaps and compares its performance with a flap-free baseline design. The flap concept is intended to mitigate hot-air recirculation during the suction phase and thereby improve near-field cooling in confined layouts. Experiments were conducted under a 350 Hz, 60 Vpp driving signal with an exit dimension of 20 mm × 1 mm. An initial screening campaign evaluated 24 flap configurations by varying flap length, thickness, and installation distance; the results showed that overly long flaps impose substantial blockage and momentum loss, and therefore the flow analysis was narrowed to a practical flap length of 29.5 mm. The final velocity characterization focuses on two representative flap thicknesses (0.1 mm and 0.5 mm) and three installation distances (5, 10, and 15 mm from the exit). For heat transfer evaluation, the nozzle-to-target spacing was varied from 5 to 50 mm in 5 mm increments. The modified actuator demonstrates improved near-field cooling performance, with the best case achieved using 0.1 mm flaps installed at 5 mm, yielding a maximum Nusselt number enhancement of 6.24% relative to the baseline at very small spacings. Furthermore, the thermal benefit becomes more pronounced at elevated heat source temperatures, with the strongest improvement observed around 60–80 °C (up to ~13% at 60 °C). These results provide practical design guidance for enhancing localized convective heat transfer in compact electronics cooling applications. Full article
Show Figures

Figure 1

23 pages, 4025 KB  
Article
Consequence-Based Assessment of Hydrogen Jet-Fire Hazards in a Port Hydrogen Refueling Station: Theory–CFD Coupling and Wind-Affected Thermal Impact Zoning
by Liying Zhong, Ming Yang, Shuang Liu, Ting Liu, Weiyi Cui and Liang Tong
Appl. Sci. 2026, 16(6), 2859; https://doi.org/10.3390/app16062859 - 16 Mar 2026
Viewed by 566
Abstract
Port-area hydrogen refueling stations face low-frequency but high-consequence events when high-pressure leaks ignite as jet fires in wind-exposed, constrained environments. This study develops a consequence-based framework coupling theoretical screening, CFD combustion analysis, and hazard zoning to support separation-distance setting and emergency planning. A [...] Read more.
Port-area hydrogen refueling stations face low-frequency but high-consequence events when high-pressure leaks ignite as jet fires in wind-exposed, constrained environments. This study develops a consequence-based framework coupling theoretical screening, CFD combustion analysis, and hazard zoning to support separation-distance setting and emergency planning. A jet-fire model estimates flame-impingement distances for multiple leak diameters, and a weighted multi-point radiation model predicts heat-flux fields, from which lethal and irreversible-injury zones are delineated using thresholds of 7 and 5 kW/m2, respectively. To move beyond wind-free screening, steady reacting-flow CFD is conducted for a representative release under four ambient conditions, with 4.34 m/s adopted as the representative wind speed for the windy cases based on Ningbo Port conditions. Validation against a visible-flame correlation defined by T ≥ 1573 K shows a deviation of 6.99%. Results show that radiation footprints expand markedly with diameter, with lethal and injury distances scaling approximately linearly within the studied range. Under wind, near-ground hot-plume extents defined by T ≥ 388 K and T ≥ 582 K depend strongly on wind direction and station geometry, whereas visible flame length is less sensitive. Additional sensitivity analyses indicate that the quasi-steady results are weakly affected by the selected ignition snapshot, while inclined releases modify projected plume/flame extents without altering the main engineering interpretation of the baseline case. The results support theory-based preliminary screening, but wind direction should be explicitly considered in exclusion-zone definition. Full article
Show Figures

Figure 1

21 pages, 5818 KB  
Article
Effect of Impinging Jet Ventilation System Geometry and Location on Thermal Comfort Achievements and Flow Characteristics
by Naif Albelwi, Abdullah M.A. Alsharif, Abdulrhman Farran, H. A. Refaey and Mohamed A. Karali
Buildings 2026, 16(3), 639; https://doi.org/10.3390/buildings16030639 - 3 Feb 2026
Cited by 1 | Viewed by 733
Abstract
Impinging jet ventilation (IJV) systems have attracted significant attention due to their potential to augment indoor thermal comfort and airflow distribution. Previous studies have primarily investigated corner and mid-wall IJV installations; however, comparative analyses focusing on different diffuser geometries remain limited. [...] Read more.
Impinging jet ventilation (IJV) systems have attracted significant attention due to their potential to augment indoor thermal comfort and airflow distribution. Previous studies have primarily investigated corner and mid-wall IJV installations; however, comparative analyses focusing on different diffuser geometries remain limited. Accordingly, this study examines the combined effects of IJV diffuser geometry and installation location on thermal comfort indices and airflow characteristics. A full three-dimensional computational fluid dynamics (CFD) model, without the use of symmetry, is developed to simulate a realistic office environment (3 × 3 × 2.9 m3), operating in cooling mode under hot summer climatic conditions. Three IJV diffuser cross-section geometries—triangular, square, and circular—are evaluated at four installation locations (two corners and two mid-wall positions), assuming a fixed occupant location. A combined return and exhaust outlet configuration is adopted. The results indicate that the IJV location influences airflow and temperature distributions more strongly than the diffuser geometry. Nevertheless, the circular diffuser exhibits superior performance compared to the triangular and square geometries. The mid-wall location placed behind the occupant and away from the hot exterior wall demonstrates reduced thermal stratification, improved airflow characteristics, and weaker vortex formation, making it the most favorable configuration. From an architectural perspective, these findings highlight the importance of early coordination between ventilation design and office spatial planning, as diffuser placement directly influences occupant comfort zones and furniture layout. Moreover, the preference for mid-wall installations supports a more flexible façade design and allows for greater freedom in organizing workspaces without compromising thermal performance. Full article
(This article belongs to the Topic Indoor Air Quality and Built Environment)
Show Figures

Figure 1

19 pages, 3803 KB  
Article
Impact of Purge Injection on Rim Seal Performance
by Matteo Caciolli, Lorenzo Orsini, Alessio Picchi, Alessio Bonini and Bruno Facchini
Appl. Sci. 2026, 16(3), 1226; https://doi.org/10.3390/app16031226 - 25 Jan 2026
Viewed by 552
Abstract
One of the most critical challenges in gas turbine design is preventing the ingestion of hot mainstream gases into the disk space between the stator and rotor disks. Rim seals and superposed sealant flows are commonly used to mitigate the risk of component [...] Read more.
One of the most critical challenges in gas turbine design is preventing the ingestion of hot mainstream gases into the disk space between the stator and rotor disks. Rim seals and superposed sealant flows are commonly used to mitigate the risk of component overheating. However, leakage paths inevitably form between the mating interfaces of adjacent components due to the complex architecture of the engine. Therefore, the interaction between the different flows present within the disk space complicates the accurate determination of the optimal sealing flow quantity. For this reason, this study experimentally investigates fluid dynamics inside a stator–rotor cavity, with a particular focus on leakage flows. In particular, this work examines the impact of multiple parameters, including injection radius position, number of leakage holes, and injection angle, on the sealing effectiveness values measured on the stator side of the cavity through CO2 gas sampling measurements. By comparing the effectiveness values with the swirl measurements derived from static and total pressure readings, the development of flow structures and the impact of leakage injection on sealing performance were finally evaluated. The results indicate that leakage injection has a minimal effect on the sealing effectiveness above the injection point, but significantly improves the performance at a lower radius. Moreover, it was observed that for a given mass flow rate, using a lower number of holes results in worse sealing performance due to a higher jet momentum, which causes the leakage flow to penetrate through the cavity toward the rotor side. In the end, employing two distinct injection angles—both aligned with the rotor’s direction of rotation—showed no substantial impact on sealing effectiveness. Full article
(This article belongs to the Special Issue Advances in Computational and Experimental Fluid Dynamics)
Show Figures

Figure 1

Back to TopTop