Sign in to use this feature.

Years

Between: -

Subjects

remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline

Journals

Article Types

Countries / Regions

Search Results (30)

Search Parameters:
Keywords = flammable refrigerants

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
20 pages, 1746 KB  
Article
Experimental Research and Simulation for the Performance of an R290 Heat Pump with Independent Compression
by Jiangqi He and Tingxun Li
Energies 2026, 19(14), 3367; https://doi.org/10.3390/en19143367 - 16 Jul 2026
Viewed by 414
Abstract
Since the Kigali Amendment entered into force globally, propane (R290) has been regarded as one of the most promising next-generation alternative refrigerants for refrigeration and air conditioning. However, its flammability limits its maximum charge amount and leads to higher flow resistance loss. In [...] Read more.
Since the Kigali Amendment entered into force globally, propane (R290) has been regarded as one of the most promising next-generation alternative refrigerants for refrigeration and air conditioning. However, its flammability limits its maximum charge amount and leads to higher flow resistance loss. In this paper, a novel refrigeration cycle with an additional independent compression process was simulated and experimentally tested. The simulation error of capacity was less than 7.1%. The intermediate evaporation temperature was optimized. The results show that the new cycle delivers stable performance advantages over the conventional R290 heat pump in both cooling and heating modes, with average capacity and COP improvements of 4.8% and 7.8% for cooling, and 8.3% and 7.5% for heating. System flow resistance loss decreases by 33.0%, which raises the refrigerant mass flow rate by 12.5% and reduces the required compressor displacement by 6.6% at equivalent cooling capacity on average. Full article
(This article belongs to the Special Issue Advanced Energy-Efficient Heat Pump Systems)
Show Figures

Figure 1

21 pages, 3446 KB  
Article
Cold-Chain Compatible Ethyl Formate Fumigation for Phytosanitary Disinfestation of Drosophila suzukii in Blueberries
by Changyao Shan, Li Li, Hang Zou, Ronghua Chen, Baishu Li and Tao Liu
Insects 2026, 17(6), 580; https://doi.org/10.3390/insects17060580 - 2 Jun 2026
Viewed by 465
Abstract
Ethyl formate (EF) is a promising alternative to methyl bromide for postharvest disinfestation, but berry export chains require efficacy under refrigerated handling without loss of marketable quality. Using spotted-wing drosophila (Drosophila suzukii) in blueberries as a cold-chain model, we compared stage-specific [...] Read more.
Ethyl formate (EF) is a promising alternative to methyl bromide for postharvest disinfestation, but berry export chains require efficacy under refrigerated handling without loss of marketable quality. Using spotted-wing drosophila (Drosophila suzukii) in blueberries as a cold-chain model, we compared stage-specific tolerance at 5 to 15 °C and identified 1-day-old eggs as the most tolerant stage, with mortality strongly temperature dependent. Egg-stage concentration to mortality relationships were quantified under 4 h exposures at 5, 10, and 15 °C to nominate temperature-specific intensities within EF flammability safety limits. Candidate schedules (69, 83, and 94 mg·L−1 for 4 h at 5, 10, and 15 °C) were confirmed by verification-scale zero-survivor tests under simulated cold-chain conditions, achieving complete control of the most tolerant egg stage. Post-treatment quality was assessed after 1, 7, and 14 days of cold storage. Weight loss, firmness, total soluble solids, titratable acidity, sucrose, and proanthocyanidins were driven mainly by storage time and temperature. EF effects were limited to transiently elevated respiration early in storage, with no detectable injury, decay, or adverse changes in appearance or other physicochemical attributes. Overall, EF provides a cold-chain compatible processing window integrating efficacy, operational safety, and quality preservation for refrigerated blueberry export logistics. Full article
(This article belongs to the Section Insect Pest and Vector Management)
Show Figures

Figure 1

13 pages, 1396 KB  
Article
Predictive Repair of Vehicle R1234yf Refrigerant Systems Based on Monitoring of Micro-Leakages
by Jozsef Nagy and Istvan Lakatos
Machines 2026, 14(3), 268; https://doi.org/10.3390/machines14030268 - 27 Feb 2026
Viewed by 1044
Abstract
To protect the environment, the R1234yf refrigerant was introduced into the air conditioning systems of modern vehicles. Its price is much higher than that of previous refrigerants, and the gas is slightly flammable, making the prompt detection and repair of even small leaks [...] Read more.
To protect the environment, the R1234yf refrigerant was introduced into the air conditioning systems of modern vehicles. Its price is much higher than that of previous refrigerants, and the gas is slightly flammable, making the prompt detection and repair of even small leaks even more critical. This research aimed to develop a simple, dashboard-based method for serially monitoring and visualizing anomalies in cars after production and before and shortly after delivery. It is possible to infer the presence of minor leaks through online or frequent pressure monitoring after the system has been “resting” (last ignition off for at least 5 h to allow system stabilization: air conditioner vs. outer or engine coolant temperature). Using this method, it can be determined whether the given pressure losses fall within the normal operating range. The essence of the technique is to detect a possible small amount of leakage by monitoring the pressure change (Δp) of the air conditioning system, supported by dashboard(s). The results on the test fleet with 500 cars show that the procedure can be suitable for detecting defects that cause micro-leaks immediately after production. The false-negative detection rate was 0.2, and the false-positive rate was 1.2 at a threshold of ±0.5 bar. Based on a practical example, the method can also be applied to offline cars until the first factory-related claim occurs. Full article
(This article belongs to the Section Vehicle Engineering)
Show Figures

Figure 1

58 pages, 4082 KB  
Review
Phase Change Materials for Thermal Management in Lithium-Ion Battery Packs: A Review
by Adrian Calborean, Levente Máthé and Olivia Bruj
Batteries 2025, 11(12), 432; https://doi.org/10.3390/batteries11120432 - 24 Nov 2025
Cited by 29 | Viewed by 9525
Abstract
In the continuous demand for high-performance lithium-ion batteries (LIBs), thermal management control is, these days, crucial with respect to safety, performance, and longevity. As a promising passive solution, Phase Change Materials (PCMs) have been implemented to overcome the conventional battery thermal management (BTM) [...] Read more.
In the continuous demand for high-performance lithium-ion batteries (LIBs), thermal management control is, these days, crucial with respect to safety, performance, and longevity. As a promising passive solution, Phase Change Materials (PCMs) have been implemented to overcome the conventional battery thermal management (BTM) approaches, including air cooling, liquid cooling, or refrigerant-based systems. Their ability to transfer the heat during phase change processes makes them ideal candidates for further thermal buffers, thus allowing compact and energy-efficient temperature control without extra power consumption. This work encompasses the recent progress in PCM-based battery thermal management systems, with a particular focus on material selection, structural design, and experimental validation. Current advances in composite PCMs, including the use of high-conductivity additives, porous supports, and encapsulation methods, are here appraised in terms of their thermal conductivity, cycling stability, leakage prevention, and overall safety. Comparisons between organic, inorganic, and hybrid PCM types demonstrate the benefits and drawbacks of each class. Ongoing discussion is also directed towards challenges that include low thermal conductivity, limited heat storage capacity, scalability, cost, and flammability. Future development opportunities are also identified in the areas of multifunctional PCMs, hybrid passive–active cooling approaches, scalable processing, and life-cycle considerations. Full article
Show Figures

Figure 1

24 pages, 3162 KB  
Review
Advances in Flame-Retardant Coatings for Rigid Polyurethane Foams: A Critical Review
by Qinhe Guo, Jiong Chen, Lulu Xu, Min Chen, Yan Zhang, Yi Xiao, Yao Yuan, Kate Nguyen and Wei Wang
Fire 2025, 8(11), 419; https://doi.org/10.3390/fire8110419 - 28 Oct 2025
Cited by 9 | Viewed by 4682
Abstract
Rigid polyurethane foams (RPUFs) are essential polymeric materials, prized for their low density, high mechanical strength, and superior thermal insulation, making them indispensable in construction, refrigeration, and transportation. Despite these advantages, their highly porous, carbon-rich structure renders them intrinsically flammable, promoting rapid flame [...] Read more.
Rigid polyurethane foams (RPUFs) are essential polymeric materials, prized for their low density, high mechanical strength, and superior thermal insulation, making them indispensable in construction, refrigeration, and transportation. Despite these advantages, their highly porous, carbon-rich structure renders them intrinsically flammable, promoting rapid flame spread, intense heat release, and the generation of toxic smoke. Traditional strategies to reduce flammability have primarily focused on incorporating additive or reactive flame retardants into the foam matrix, which can effectively suppress combustion but often compromise mechanical integrity, suffer from migration or compatibility issues, and involve complex synthesis routes. Despite recent progress, the long-term stability, scalability, and durability of surface flame-retardant coatings for RPUFs remain underexplored, limiting their practical application in industrial environments. Recent advances have emphasized the development of surface-engineered flame-retardant coatings, including intumescent systems, inorganic–organic hybrids, bio-inspired materials, and nanostructured composites. These coatings form protective interfaces that inhibit ignition, restrict heat and mass transfer, promote char formation, and suppress smoke without altering the intrinsic properties of RPUFs. Emerging deposition methods, such as layer-by-layer assembly, spray coating, ultraviolet (UV) curing, and brush application, enable precise control over thickness, uniformity, and adhesion, enhancing durability and multifunctionality. Integrating bio-based and hybrid approaches further offers environmentally friendly and sustainable solutions. Collectively, these developments demonstrate the potential of surface-engineered coatings to achieve high-efficiency flame retardancy while preserving thermal and mechanical performance, providing a pathway for safe, multifunctional, and industrially viable RPUFs. Full article
(This article belongs to the Special Issue Smart Firefighting Technologies and Advanced Materials)
Show Figures

Figure 1

24 pages, 4420 KB  
Article
Study on the Replacement of Rail Vehicle Air-Conditioning Refrigerants with Low-GWP Refrigerant Mixtures
by Yuxin Zhang, Chun Song, Jianbin Zang, Xinge Chen and Chongyu Lu
Energies 2025, 18(19), 5164; https://doi.org/10.3390/en18195164 - 28 Sep 2025
Viewed by 1353
Abstract
This study addresses the urgent demand for low-GWP refrigerant alternatives in rail vehicle air-conditioning systems by proposing a novel binary mixture, ZT01 (R13I1/R32 = 0.6/0.4 by mass), as a replacement for R407C. A comprehensive evaluation combining thermodynamic cycle modeling, refrigerant property analysis, and [...] Read more.
This study addresses the urgent demand for low-GWP refrigerant alternatives in rail vehicle air-conditioning systems by proposing a novel binary mixture, ZT01 (R13I1/R32 = 0.6/0.4 by mass), as a replacement for R407C. A comprehensive evaluation combining thermodynamic cycle modeling, refrigerant property analysis, and experimental validation shows that ZT01 delivers a coefficient of performance (COP) comparable to R407C, while providing a 45–49% improvement in volumetric cooling capacity, enabling smaller compressor displacement for the same cooling output, and reducing specific compressor work by 13–21%. In addition, ZT01 maintains a lower compression ratio, exhibits non-flammability, is compatible with POE lubricant, and has a GWP of only 308. Life Cycle Climate Performance (LCCP) analysis further indicates a 6.88% reduction in total carbon emissions and a 77.4% reduction in direct emissions compared to R407C, demonstrating that ZT01 is both technically feasible and environmentally sustainable for green retrofitting of rail vehicle HVAC systems. Full article
(This article belongs to the Topic Heat and Mass Transfer in Engineering)
Show Figures

Figure 1

21 pages, 3199 KB  
Article
Explosion of Flammable Propane Refrigerants Leaked in an MiC Unit
by Cheuklun Chow, Zheming Gao, Shousuo Han and Wanki Chow
Fire 2025, 8(10), 378; https://doi.org/10.3390/fire8100378 - 23 Sep 2025
Cited by 2 | Viewed by 2085
Abstract
Modular Integrated Construction (MiC) has been strongly promoted in many dense urban areas, including the Greater Bay Area. There might be an explosion risk if leaked flammable clean refrigerants accumulate in a confined unit. Experimental and modeling studies on the explosion of flammable [...] Read more.
Modular Integrated Construction (MiC) has been strongly promoted in many dense urban areas, including the Greater Bay Area. There might be an explosion risk if leaked flammable clean refrigerants accumulate in a confined unit. Experimental and modeling studies on the explosion of flammable refrigerant propane in an MiC unit were carried out with a rectangular unit model to explore well-covered or partially covered conditions, representing the scenario of an MiC unit with its door open or closed. The experimental results were used in developing an analytical model to predict the flame surface and pressure change, with acceptable results. This study could be used as a reference for estimating pressure changes and designing ventilation systems to prevent deflagration in MiC units. Full article
Show Figures

Figure 1

15 pages, 21805 KB  
Article
Case Study on the Rupture Morphology of a Copper Tube in an Air Conditioner Condenser After Fire
by Yunlong Ou, Ming Fu, Jing Zhang, Wenzhong Mi, Changzheng Li, Shouhai Chen and Shoulei Zheng
Fire 2025, 8(4), 145; https://doi.org/10.3390/fire8040145 - 4 Apr 2025
Cited by 1 | Viewed by 4704
Abstract
The new eco-friendly flammable refrigerant in air conditioners has resulted in an annual increase in fire incidents associated with these units. Fire investigators face significant challenges in identifying the causes of these fires. In this study, copper tube samples were extracted from various [...] Read more.
The new eco-friendly flammable refrigerant in air conditioners has resulted in an annual increase in fire incidents associated with these units. Fire investigators face significant challenges in identifying the causes of these fires. In this study, copper tube samples were extracted from various locations of air conditioner condenser debris post fire. The morphology characteristics of the ruptured copper tubes formed by a high-temperature flame in fire and that formed by corrosion were analyzed, respectively. The findings indicate that the ruptures in the copper tubes of air conditioners may be classified into two types based on their origins: ruptures resulting from fire and ruptures resulting from corrosion. The ruptures in the copper tubes resulting from fire are associated with the presence of aluminum alloy fins. At elevated temperatures, the copper and aluminum atoms persist in diffusing and fracturing. A significant quantity of silver-white aluminum is present surrounding the ruptures, and distinct elemental layers may be seen in the cross-section. The corrosion-induced ruptures in the copper tubes are associated with ant nest corrosion. Despite the influence of high-temperature flame melting on surface corrosion pits, they will not entirely obscure the pits and the cross-section continues to exhibit the bifurcated structure characteristic of ant nest corrosion. This investigation demonstrates that corrosion of ant nests is the root cause of copper tube breakage obscured by flames. An investigation method for the refrigerant leakage air conditioning fire is proposed. The above findings can provide proof and method for air conditioning fire investigation. Full article
(This article belongs to the Special Issue Fire Detection and Public Safety, 2nd Edition)
Show Figures

Figure 1

17 pages, 13790 KB  
Article
Research on the Diffusion and Deposition Characteristics of Refrigerant Under Vertical Upward Leakage in a Confined Space
by Yongjun Ling, Ning Jiang, Xuan Zhou, Yalun Li, Peixu Zhou, Yongjie Lu and Xiaohong Han
Appl. Sci. 2025, 15(4), 1918; https://doi.org/10.3390/app15041918 - 12 Feb 2025
Viewed by 1883
Abstract
In a confined space, the flammability of alternative refrigerants (such as R717, R290, R32, and R1234yf) poses significant safety risks during leaks. However, in the actual refrigeration systems, the direction of refrigerant leakage is difficult to predict, complicating explosion risk assessment. In this [...] Read more.
In a confined space, the flammability of alternative refrigerants (such as R717, R290, R32, and R1234yf) poses significant safety risks during leaks. However, in the actual refrigeration systems, the direction of refrigerant leakage is difficult to predict, complicating explosion risk assessment. In this work, R717, R290, R32, and R1234yf were selected as the research objects to analyze the diffusion process and deposition characteristics of different refrigerants leaking vertically upward into a confined space, and to explore the migration characteristics of flammable refrigerants under different leakage amounts and flammability area in a confined space. The results show that after vertical upward leakage, the refrigerants tend to impact the top wall and then move along the top wall away from the leak source. High-density refrigerants diffuse primarily near the floor, while less dense refrigerant diffuses along the top and side wall of the space. After the refrigerant leakage stops, R1234yf, with the highest density, exhibited the most pronounced deposition, with the highest concentration near the floor and the lowest at the top (1.69% and 0.7%, respectively). Conversely, lower-density refrigerants showed decreasing floor concentrations and increasing top concentrations, with reduced overall deposition. Compared to the deposition concentration of R290 at the bottom of the room (1.32%), R744 demonstrated higher deposition near the floor than R290, likely due to its higher viscosity at similar densities. In addition, using R290 as an example, the study reveals that the increase in leakage amount and the prolonged time result in a gradual expansion and upward diffusion of the flammability area, encompassing the top of the space, walls, and floor. Full article
(This article belongs to the Section Energy Science and Technology)
Show Figures

Figure 1

22 pages, 7417 KB  
Article
A Novel Approach of −80 °C Cascade Refrigeration System Using Non-Flammable Quaternary Refrigerants for Semiconductor Process Applications
by Su-Been Lee, Chang-Hyo Son and Joon-Hyuk Lee
Energies 2024, 17(23), 6178; https://doi.org/10.3390/en17236178 - 7 Dec 2024
Cited by 1 | Viewed by 2974
Abstract
Ultra-low temperature chillers have seen increasing demand with the advancement of semiconductor technology. Mixed refrigerant (MR) cascade refrigeration systems (CRSs) are widely utilized for their stability and high cooling performance at low temperatures. Extensive research has been conducted on optimizing MR, which has [...] Read more.
Ultra-low temperature chillers have seen increasing demand with the advancement of semiconductor technology. Mixed refrigerant (MR) cascade refrigeration systems (CRSs) are widely utilized for their stability and high cooling performance at low temperatures. Extensive research has been conducted on optimizing MR, which has a significant impact on CRS performance. However, most previous studies have either fixed the system pressure or used the refrigeration effect as the sole performance indicator. This did not account for the potential of achieving higher performance with an optimal MR composition at the same target temperature. In this study, a detailed parametric analysis was performed to investigate how the mass fractions of high-, mid-, and low boiling point refrigerants affect the coefficient of performance (COP) and exergy in ultra-low temperature CRSs without fixing the suction pressure. The analysis revealed that at the point of maximum COP, the refrigeration effect was relatively low, highlighting the limitations of using the refrigeration effect alone as a performance indicator. Additionally, COP was found to inversely correlate with total exergy destruction. As cascade temperature increases, COP tends to decrease, emphasizing the need for appropriate cascade temperature selection for MR CRS performance. This study introduces a novel approach to optimizing MR composition under various operating conditions, contributing to the advancement of ultra-low temperature CRSs. Full article
(This article belongs to the Section K: State-of-the-Art Energy Related Technologies)
Show Figures

Figure 1

25 pages, 5478 KB  
Article
Proposals for Next-Generation Eco-Friendly Non-Flammable Refrigerants for a −100 °C Semiconductor Etching Chiller Based on 4E (Energy, Exergy, Environmental, and Exergoeconomic) Analysis
by Hye-In Jung, Chang-Hyo Son and Joon-Hyuk Lee
Energies 2024, 17(19), 4969; https://doi.org/10.3390/en17194969 - 4 Oct 2024
Cited by 1 | Viewed by 2183
Abstract
Recent advancements in cryogenic etching, characterized by high aspect ratios and etching rates, address the growing demand for enhanced performance and reduced power consumption in electronics. To precisely maintain the temperature under high loads, the cascade mixed-refrigerant cycle (CMRC) is predominantly used. However, [...] Read more.
Recent advancements in cryogenic etching, characterized by high aspect ratios and etching rates, address the growing demand for enhanced performance and reduced power consumption in electronics. To precisely maintain the temperature under high loads, the cascade mixed-refrigerant cycle (CMRC) is predominantly used. However, most refrigerants currently used in semiconductor cryogenic etching have high global warming potential (GWP). This study introduces a −100 °C chiller using a mixed refrigerant (MR) with a GWP of 150 or less, aiming to comply with stricter environmental standards and contribute to environmental preservation. The optimal configuration for the CMRC was determined based on a previously established methodology for selecting the best MR configuration. Comprehensive analyses—energy, exergy, environmental, and exergoeconomic—were conducted on the data obtained using Matlab simulations to evaluate the feasibility of replacing conventional refrigerants. The results reveal that using eco-friendly MRs increases the coefficient of performance by 52%, enabling a reduction in compressor size due to significantly decreased discharge volumes. The exergy analysis indicated a 16.41% improvement in efficiency and a substantial decrease in exergy destruction. The environmental analysis demonstrated that eco-friendly MRs could reduce carbon emissions by 60%. Economically, the evaporator and condenser accounted for over 70% of the total exergy costs in all cases, with a 52.44% reduction in exergy costs when using eco-friendly MRs. This study highlights the potential for eco-friendly refrigerants to be integrated into semiconductor cryogenic etching processes, responding effectively to environmental regulations in the cryogenic sector. Full article
(This article belongs to the Section J: Thermal Management)
Show Figures

Figure 1

9 pages, 524 KB  
Proceeding Paper
Future Trends of Natural Refrigerants: Selection, Preparation, and Evaluation
by Sheila Mae R. Bantillo, Gen Aaron C. Callejo, Samantha Mariya Kaila G. Camacho, Mark Anthony Montalban, Raven E. Valderin and Rugi Vicente C. Rubi
Eng. Proc. 2024, 67(1), 9; https://doi.org/10.3390/engproc2024067009 - 8 Aug 2024
Cited by 12 | Viewed by 7021
Abstract
The field of refrigeration technology has played a pivotal role in modern society, providing essential cooling solutions for various industries, including food preservation, healthcare, and manufacturing. However, the conventional refrigerants used in these systems, such as hydrofluorocarbons (HFCs) and chlorofluorocarbons (CFCs), have been [...] Read more.
The field of refrigeration technology has played a pivotal role in modern society, providing essential cooling solutions for various industries, including food preservation, healthcare, and manufacturing. However, the conventional refrigerants used in these systems, such as hydrofluorocarbons (HFCs) and chlorofluorocarbons (CFCs), have been identified as major contributors to climate change and ozone depletion. Recently, the heightened environmental consciousness of the refrigeration industry paved the way for searching for natural refrigerants (NRs) as an alternative to the usual commercial and synthetic refrigerant (SR). Natural refrigerants are known to be substances that occur naturally in the Earth’s surroundings and were commonly used, while synthetic refrigerants took their place because of their known better thermal performance durability and safety. Despite challenges such as flammability and toxicity, these NR substitutes demonstrate competitive performance, urging a transition from traditional SR. In this review paper, commonly known NRs such as ammonia, carbon dioxide, air, and hydrocarbons, are presented in terms of their sustainable characteristics, historical origins, selection criteria, preparation techniques, evaluations, and impacts. To provide a sustainable and eco-friendly guideline for the advancement of refrigeration technology, this analysis examines the trends, selection criteria, preparation processes, and evaluation procedures of different NRs. Finally, the results presented in this paper will be useful baseline information for both researchers and scientists in developing a refrigeration system. Full article
(This article belongs to the Proceedings of The 3rd International Electronic Conference on Processes)
Show Figures

Figure 1

21 pages, 9557 KB  
Article
Cooling and Multiphase Analysis of Heated Environmentally Friendly R152A (C2H4F2) Fluid Coming from the Production Process According to Nist Indicators
by Mehmet Akif Kartal, Gürcan Atakök and Sezgin Ersoy
Appl. Sci. 2024, 14(10), 4143; https://doi.org/10.3390/app14104143 - 14 May 2024
Cited by 7 | Viewed by 2425
Abstract
Cooling processes are responsible for a significant portion (20%) of global energy consumption and raise environmental concerns such as ozone depletion, the greenhouse effect, and high energy use. This study investigates the potential of R152a, a refrigerant with low global warming potential (GWP), [...] Read more.
Cooling processes are responsible for a significant portion (20%) of global energy consumption and raise environmental concerns such as ozone depletion, the greenhouse effect, and high energy use. This study investigates the potential of R152a, a refrigerant with low global warming potential (GWP), as a more sustainable alternative. The performance, safety, and operational efficiency of R152a were evaluated under various conditions. Although R152a offers high performance and low GWP, its flammability necessitates caution, especially in certain mixtures. A 12-pass tube-type heat exchanger model was simulated using computational fluid dynamics (CFD) to analyze the fluid behavior within the exchanger. The pressure, density, dynamic pressure, Prandtl number, total pressure, and temperature distributions for both R152a and H2O (water) were visualized using contour plots. The simulations comprehensively examined the fluid behavior inside and outside the heat exchanger. The results revealed the influence of the temperature on the internal dynamic pressure and density of R152a. Compared with R134a, R152a demonstrated superior performance but a lower coefficient of performance (COP) than R32. Studies also suggest that R152a exhibits lower irreversibility in Organic Rankine Cycle (ORC) systems than R245fa. These findings suggest that R152a holds promise for future refrigeration systems, as supported by existing research on its performance and compatibility. One study focused on optimizing the heat exchanger performance by maximizing the heat capacity and minimizing the pressure drop. This study employed a parallel-flow heat exchanger with R152a as the coolant for the hot process water. The temperature changes, pressure drops, and resulting energy efficiency and thermal performance of both fluids were analyzed. The results highlight the distinct energy efficiencies and thermal performance of the employed fluids. Full article
(This article belongs to the Special Issue Advances and Applications of CFD (Computational Fluid Dynamics))
Show Figures

Figure 1

12 pages, 6497 KB  
Article
A Modeling-Based Flammable Risk Treatment of Refrigerant Leakage from a Commercial R-290 Refrigeration Machine
by Mingkan Zhang, Vishaldeep Sharma and Praveen Cheekatamarla
Inventions 2024, 9(3), 53; https://doi.org/10.3390/inventions9030053 - 4 May 2024
Cited by 7 | Viewed by 3079
Abstract
Because of serious concerns about global warming, manufacturers have started phasing out high global warming potential (GWP) refrigerants in commercial refrigeration equipment (e.g., R-134a). As a potential replacement, propane (R-290) is an environmentally friendly refrigerant for commercial refrigeration equipment because its GWP is [...] Read more.
Because of serious concerns about global warming, manufacturers have started phasing out high global warming potential (GWP) refrigerants in commercial refrigeration equipment (e.g., R-134a). As a potential replacement, propane (R-290) is an environmentally friendly refrigerant for commercial refrigeration equipment because its GWP is only three. However, propane is flammable and is therefore classified as a Class A3 refrigerant per ASHRAE Standards, so safety is a very important consideration when propane-based equipment is designed and deployed in buildings. In the event of a refrigerant leak, flammability of the refrigerant depends on the refrigerant’s local concentration, which is highly affected by the indoor air environment, including temperature and air flow. In this study, a ventilation system attached to a commercial R-290 refrigeration device was designed to eliminate the flammability risk. Moreover, a computational fluid dynamics (CFD) model was developed to investigate the refrigerant leak, thereby evaluating effects of the ventilation system. The CFD model can visualize the flammable zones owing to the leak. Full article
(This article belongs to the Special Issue Thermodynamic and Technical Analysis for Sustainability (Volume 3))
Show Figures

Figure 1

74 pages, 8424 KB  
Review
Review of Organic Rankine Cycles for Internal Combustion Engine Waste Heat Recovery: Latest Decade in Review
by Charles E. Sprouse
Sustainability 2024, 16(5), 1924; https://doi.org/10.3390/su16051924 - 26 Feb 2024
Cited by 36 | Viewed by 14848
Abstract
The last decade (2013–2023) was the most prolific period of organic Rankine cycle (ORC) research in history in terms of both publications and citations. This article provides a detailed review of the broad and voluminous collection of recent internal combustion engine (ICE) waste [...] Read more.
The last decade (2013–2023) was the most prolific period of organic Rankine cycle (ORC) research in history in terms of both publications and citations. This article provides a detailed review of the broad and voluminous collection of recent internal combustion engine (ICE) waste heat recovery (WHR) studies, serving as a necessary follow-on to the author’s 2013 review. Research efforts have targeted diverse applications (e.g., vehicular, stationary, and building-based), and it spans the full gamut of engine sizes and fuels. Furthermore, cycle configurations extend far beyond basic ORC and regenerative ORC, particularly with supercritical, trilateral, and multi-loop ORCs. Significant attention has been garnered by fourth-generation refrigerants like HFOs (hydrofluoroolefins), HFEs (hydrofluoroethers), natural refrigerants, and zeotropic mixtures, as research has migrated away from the popular HFC-245fa (hydrofluorocarbon). Performance-wise, the period was marked by a growing recognition of the diminished performance of physical systems under dynamic source conditions, especially compared to steady-state simulations. Through advancements in system control, especially using improved model predictive controllers, dynamics-based losses have been significantly reduced. Regarding practically minded investigations, research efforts have ameliorated working fluid flammability risks, limited thermal degradation, and pursued cost savings. State-of-the-art system designs and operational targets have emerged through increasingly sophisticated optimization efforts, with some studies leveraging “big data” and artificial intelligence. Major programs like SuperTruck II have further established the ongoing challenges of simultaneously meeting cost, size, and performance goals; however, off-the-shelf organic Rankine cycle systems are available today for engine waste heat recovery, signaling initial market penetration. Continuing forward, next-generation engines can be designed specifically as topping cycles for an organic Rankine (bottoming) cycle, with both power sources integrated into advanced hybrid drivetrains. Full article
(This article belongs to the Topic Advanced Engines Technologies)
Show Figures

Figure 1

Back to TopTop