Sign in to use this feature.

Years

Between: -

Subjects

remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline

Journals

remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline

Article Types

Countries / Regions

remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline

Search Results (721)

Search Parameters:
Keywords = facility condition assessment

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
35 pages, 6795 KiB  
Article
Thermal Analysis of Energy Efficiency Performance and Indoor Comfort in a LEED-Certified Campus Building in the United Arab Emirates
by Khushbu Mankani, Mutasim Nour and Hassam Nasarullah Chaudhry
Energies 2025, 18(15), 4155; https://doi.org/10.3390/en18154155 - 5 Aug 2025
Abstract
Enhancing the real-world performance of sustainably designed and certified green buildings remains a significant challenge, particularly in hot climates where efforts to improve thermal comfort often conflict with energy efficiency goals. In the United Arab Emirates (UAE), even newly constructed facilities with green [...] Read more.
Enhancing the real-world performance of sustainably designed and certified green buildings remains a significant challenge, particularly in hot climates where efforts to improve thermal comfort often conflict with energy efficiency goals. In the United Arab Emirates (UAE), even newly constructed facilities with green building certifications present opportunities for retrofitting and performance optimization. This study investigates the energy and thermal comfort performance of a LEED Gold-certified, mixed-use university campus in Dubai through a calibrated digital twin developed using IES thermal modelling software. The analysis evaluated existing sustainable design strategies alongside three retrofit energy conservation measures (ECMs): (1) improved building envelope U-values, (2) installation of additional daylight sensors, and (3) optimization of fan coil unit efficiency. Simulation results demonstrated that the three ECMs collectively achieved a total reduction of 15% in annual energy consumption. Thermal comfort was assessed using operative temperature distributions, Predicted Mean Vote (PMV), and Predicted Percentage of Dissatisfaction (PPD) metrics. While fan coil optimization yielded the highest energy savings, it led to less favorable comfort outcomes. In contrast, enhancing envelope U-values maintained indoor conditions consistently within ASHRAE-recommended comfort zones. To further support energy reduction and progress toward Net Zero targets, the study also evaluated the integration of a 228.87 kW rooftop solar photovoltaic (PV) system, which offset 8.09% of the campus’s annual energy demand. By applying data-driven thermal modelling to assess retrofit impacts on both energy performance and occupant comfort in a certified green building, this study addresses a critical gap in the literature and offers a replicable framework for advancing building performance in hot climate regions. Full article
(This article belongs to the Special Issue Energy Efficiency and Thermal Performance in Buildings)
Show Figures

Graphical abstract

16 pages, 2048 KiB  
Article
Quantitative Determination of Nitrogen Content in Cucumber Leaves Using Raman Spectroscopy and Multidimensional Feature Selection
by Zhaolong Hou, Feng Tan, Manshu Li, Jiaxin Gao, Chunjie Su, Feng Jiao, Yaxuan Wang and Xin Zheng
Agronomy 2025, 15(8), 1884; https://doi.org/10.3390/agronomy15081884 - 4 Aug 2025
Abstract
Cucumber, a high-yielding crop commonly grown in facility environments, is particularly susceptible to nitrogen (N) deficiency due to its rapid growth and high nutrient demand. This study used cucumber as its experimental subject and established a spectral dataset of leaves under four nutritional [...] Read more.
Cucumber, a high-yielding crop commonly grown in facility environments, is particularly susceptible to nitrogen (N) deficiency due to its rapid growth and high nutrient demand. This study used cucumber as its experimental subject and established a spectral dataset of leaves under four nutritional conditions, normal supply, nitrogen deficiency, phosphorus deficiency, and potassium deficiency, aiming to develop an efficient and robust method for quantifying N in cucumber leaves using Raman spectroscopy (RS). Spectral data were preprocessed using three baseline correction methods—BaselineWavelet (BW), Iteratively Improve the Moving Average (IIMA), and Iterative Polynomial Fitting (IPF)—and key spectral variables were selected using 4-Dimensional Feature Extraction (4DFE) and Competitive Adaptive Reweighted Sampling (CARS). These selected features were then used to develop a N content prediction model based on Partial Least Squares Regression (PLSR). The results indicated that baseline correction significantly enhanced model performance, with three methods outperforming unprocessed spectra. A further analysis showed that the combination of IPF, 4DFE, and CARS achieved optimal PLSR model performance, achieving determination coefficients (R2) of 0.947 and 0.847 for the calibration and prediction sets, respectively. The corresponding root mean square errors (RMSEC and RMSEP) were 0.250 and 0.368, while the residual predictive deviation (RPDC and RPDP) values reached 4.335 and 2.555. These findings confirm the feasibility of integrating RS with advanced data processing for rapid, non-destructive nitrogen assessment in cucumber leaves, offering a valuable tool for nutrient monitoring in precision agriculture. Full article
(This article belongs to the Section Precision and Digital Agriculture)
Show Figures

Figure 1

25 pages, 3590 KiB  
Article
Effectiveness of Firefighter Training for Indoor Intervention: Analysis of Temperature Profiles and Extinguishing Effectiveness
by Jan Hora
Fire 2025, 8(8), 304; https://doi.org/10.3390/fire8080304 - 1 Aug 2025
Viewed by 194
Abstract
This study assessed the effectiveness of stress-based cognitive-behavioral training compared to standard training in firefighters, emphasizing their ability to distribute extinguishing water and cool environments evenly during enclosure fires. Experiments took place at the Zbiroh training facility with two firefighter teams (Team A [...] Read more.
This study assessed the effectiveness of stress-based cognitive-behavioral training compared to standard training in firefighters, emphasizing their ability to distribute extinguishing water and cool environments evenly during enclosure fires. Experiments took place at the Zbiroh training facility with two firefighter teams (Team A with stress-based training and Team B with standard training) under realistic conditions. Using 58 thermocouples and 4 radiometers, temperature distribution and radiant heat flux were measured to evaluate water distribution efficiency and cooling performance during interventions. Team A consistently achieved temperature reductions of approximately 320 °C in the upper layers and 250–400 °C in the middle layers, maintaining stable conditions, whereas Team B only achieved partial cooling, with upper-layer temperatures remaining at 750–800 °C. Additionally, Team A recorded lower radiant heat flux densities (e.g., 20.74 kW/m2 at 0°) compared to Team B (21.81 kW/m2), indicating more effective water application and adaptability. The findings confirm that stress-based training enhances firefighters’ operational readiness and their ability to distribute water effectively during interventions. This skill is essential for safer and effective management of indoor fires under extreme conditions. This study supports the inclusion of stress-based and scenario-based training in firefighter education to enhance safety and operational performance. Full article
Show Figures

Figure 1

29 pages, 14647 KiB  
Article
Precipitation Processes in Sanicro 25 Steel at 700–900 °C: Experimental Study and Digital Twin Simulation
by Grzegorz Cempura and Adam Kruk
Materials 2025, 18(15), 3594; https://doi.org/10.3390/ma18153594 - 31 Jul 2025
Viewed by 250
Abstract
Sanicro 25 (X7NiCrWCuCoNb25-23-3-3-2) steel is specifically designed for use in superheater components within the latest generation of conventional power plants. These power plants operate under conditions often referred to as super-ultra-supercritical, with steam parameters that can reach up to 30 MPa and temperatures [...] Read more.
Sanicro 25 (X7NiCrWCuCoNb25-23-3-3-2) steel is specifically designed for use in superheater components within the latest generation of conventional power plants. These power plants operate under conditions often referred to as super-ultra-supercritical, with steam parameters that can reach up to 30 MPa and temperatures of 653 °C for fresh steam and 672 °C for reheated steam. While last-generation supercritical power plants still rely on fossil fuels, they represent a significant step forward in more sustainable energy production. The most sophisticated facilities of this kind can achieve thermodynamic efficiencies exceeding 47%. This study aimed to conduct a detailed analysis of the initial precipitation processes occurring in Sanicro 25 steel within the temperature range of 700–900 °C. The temperature of 700 °C corresponds to the operational conditions of this material, particularly in secondary steam superheaters in thermal power plants that operate under ultra-supercritical parameters. Understanding precipitation processes is crucial for optimizing mechanical performance, particularly in terms of long-term strength and creep resistance. To accurately assess the microstructural changes that occur during the early stages of service, a digital twin approach was employed, which included CALPHAD simulations and experimental heat treatments. Experimental annealing tests were conducted in air within the temperature range of 700–900 °C. Precipitation behavior was simulated using the Thermo-Calc 2025a with Dictra software package. The results from Prisma simulations correlated well with the experimental data related to the kinetics of phase transformations; however, it was noted that the predicted sizes of the precipitates were generally smaller than those observed in experiments. Additionally, computational limitations were encountered during some simulations due to the complexity arising from the numerous alloying elements present in Sanicro 25 steel. The microstructural evolution was investigated using various methods, including light microscopy (LM), scanning electron microscopy (SEM), and transmission electron microscopy (TEM). Full article
Show Figures

Figure 1

26 pages, 11108 KiB  
Article
Warming in the Maternal Environment Alters Seed Performance and Genetic Diversity of Stylosanthes capitata, a Tropical Legume Forage
by Priscila Marlys Sá Rivas, Fernando Bonifácio-Anacleto, Ivan Schuster, Carlos Alberto Martinez and Ana Lilia Alzate-Marin
Genes 2025, 16(8), 913; https://doi.org/10.3390/genes16080913 (registering DOI) - 30 Jul 2025
Viewed by 321
Abstract
Background/Objectives: Global warming and rising CO2 concentrations pose significant challenges to plant systems. Amid these pressures, this study contributes to understanding how tropical species respond by simultaneously evaluating reproductive and genetic traits. It specifically investigates the effects of maternal exposure to [...] Read more.
Background/Objectives: Global warming and rising CO2 concentrations pose significant challenges to plant systems. Amid these pressures, this study contributes to understanding how tropical species respond by simultaneously evaluating reproductive and genetic traits. It specifically investigates the effects of maternal exposure to warming and elevated CO2 on progeny physiology, genetic diversity, and population structure in Stylosanthes capitata, a resilient forage legume native to Brazil. Methods: Maternal plants were cultivated under controlled treatments, including ambient conditions (control), elevated CO2 at 600 ppm (eCO2), elevated temperature at +2 °C (eTE), and their combined exposure (eTEeCO2), within a Trop-T-FACE field facility (Temperature Free-Air Controlled Enhancement and Free-Air Carbon Dioxide Enrichment). Seed traits (seeds per inflorescence, hundred-seed mass, abortion, non-viable seeds, coat color, germination at 32, 40, 71 weeks) and abnormal seedling rates were quantified. Genetic diversity metrics included the average (A) and effective (Ae) number of alleles, observed (Ho) and expected (He) heterozygosity, and inbreeding coefficient (Fis). Population structure was assessed using Principal Coordinates Analysis (PCoA), Analysis of Molecular Variance (AMOVA), number of migrants per generation (Nm), and genetic differentiation index (Fst). Two- and three-way Analysis of Variance (ANOVA) were used to evaluate factor effects. Results: Compared to control conditions, warming increased seeds per inflorescence (+46%), reduced abortion (−42.9%), non-viable seeds (−57%), and altered coat color. The germination speed index (GSI +23.5%) and germination rate (Gr +11%) improved with warming; combined treatments decreased germination time (GT −9.6%). Storage preserved germination traits, with warming enhancing performance over time and reducing abnormal seedlings (−54.5%). Conversely, elevated CO2 shortened GSI in late stages, impairing germination efficiency. Warming reduced Ae (−35%), He (−20%), and raised Fis (maternal 0.50, progeny 0.58), consistent with the species’ mixed mating system; A and Ho were unaffected. Allele frequency shifts suggested selective pressure under eTE. Warming induced slight structure in PCoA, and AMOVA detected 1% (maternal) and 9% (progeny) variation. Fst = 0.06 and Nm = 3.8 imply environmental influence without isolation. Conclusions: Warming significantly shapes seed quality, reproductive success, and genetic diversity in S. capitata. Improved reproduction and germination suggest adaptive advantages, but higher inbreeding and reduced diversity may constrain long-term resilience. The findings underscore the need for genetic monitoring and broader genetic bases in cultivars confronting environmental stressors. Full article
(This article belongs to the Special Issue Genetics and Breeding of Forage)
Show Figures

Graphical abstract

25 pages, 3868 KiB  
Article
From Research to Design: Enhancing Mental Well-Being Through Quality Public Green Spaces in Beirut
by Mariam Raad, Georgio Kallas, Falah Assadi, Nina Zeidan, Victoria Dawalibi and Alessio Russo
Land 2025, 14(8), 1558; https://doi.org/10.3390/land14081558 - 29 Jul 2025
Viewed by 230
Abstract
The global rise in urban-related health issues poses significant challenges to public health, particularly in cities facing socio-economic crises. In Lebanon, 70% of the population is experiencing financial hardship, and healthcare costs have surged by 172%, exacerbating the strain on medical services. Given [...] Read more.
The global rise in urban-related health issues poses significant challenges to public health, particularly in cities facing socio-economic crises. In Lebanon, 70% of the population is experiencing financial hardship, and healthcare costs have surged by 172%, exacerbating the strain on medical services. Given these conditions, improving the quality and accessibility of green spaces offers a promising avenue for alleviating mental health issues in urban areas. This study investigates the psychological impact of nine urban public spaces in Beirut through a comprehensive survey methodology, involving 297 participants (locals and tourists) who rated these spaces using Likert-scale measures. The findings reveal location-specific barriers, with Saanayeh Park rated highest in quality and Martyr’s Square rated lowest. The analysis identifies facility quality as the most significant factor influencing space quality, contributing 73.6% to the overall assessment, while activity factors have a lesser impact. The study further highlights a moderate positive association (Spearman’s rho = 0.30) between public space quality and mental well-being in Beirut. This study employs a hybrid methodology combining Research for Design (RfD) and Research Through Designing (RTD). Empirical data informed spatial strategies, while iterative design served as a tool for generating context-specific knowledge. Design enhancements—such as sensory plantings, shading systems, and social nodes—aim to improve well-being through better public space quality. The proposed interventions support mental health, life satisfaction, climate resilience, and urban inclusivity. The findings offer actionable insights for cities facing public health and spatial equity challenges in crisis contexts. Full article
Show Figures

Figure 1

14 pages, 1829 KiB  
Article
Investigating the Spatial Biases and Temporal Trends in Insect Pollinator Occurrence Data on GBIF
by Ehsan Rahimi and Chuleui Jung
Insects 2025, 16(8), 769; https://doi.org/10.3390/insects16080769 - 26 Jul 2025
Viewed by 424
Abstract
Research in biogeography, ecology, and biodiversity hinges on the availability of comprehensive datasets that detail species distributions and environmental conditions. At the forefront of this endeavor is the Global Biodiversity Information Facility (GBIF). This study focuses on investigating spatial biases and temporal trends [...] Read more.
Research in biogeography, ecology, and biodiversity hinges on the availability of comprehensive datasets that detail species distributions and environmental conditions. At the forefront of this endeavor is the Global Biodiversity Information Facility (GBIF). This study focuses on investigating spatial biases and temporal trends in insect pollinator occurrence data within the GBIF dataset, specifically focusing on three pivotal pollinator groups: bees, hoverflies, and butterflies. Addressing these gaps in GBIF data is essential for comprehensive analyses and informed pollinator conservation efforts. We obtained occurrence data from GBIF for seven bee families, six butterfly families, and the Syrphidae family of hoverflies in 2024. Spatial biases were addressed by eliminating duplicate records with identical latitude and longitude coordinates. Species richness was assessed for each family and country. Temporal trends were examined by tallying annual occurrence records for each pollinator family, and the diversity of data sources within GBIF was evaluated by quantifying unique data publishers. We identified initial occurrence counts of 4,922,390 for bees, 1,703,131 for hoverflies, and 31,700,696 for butterflies, with a substantial portion containing duplicate records. On average, 81.4% of bee data, 77.2% of hoverfly data, and 65.4% of butterfly data were removed post-duplicate elimination for dataset refinement. Our dataset encompassed 9286 unique bee species, 2574 hoverfly species, and 17,895 butterfly species. Our temporal analysis revealed a notable trend in data recording, with 80% of bee and butterfly data collected after 2022, and a similar threshold for hoverflies reached after 2023. The United States, Germany, the United Kingdom, and Sweden consistently emerged as the top countries for occurrence data across all three groups. The analysis of data publishers highlighted iNaturalist.org as a top contributor to bee data. Overall, we uncovered significant biases in the occurrence data of pollinators from GBIF. These biases pose substantial challenges for future research on pollinator ecology and biodiversity conservation. Full article
(This article belongs to the Special Issue Insect Pollinators and Pollination Service Provision)
Show Figures

Figure 1

10 pages, 775 KiB  
Article
A Multi-Center Prospective Study on Post-Vaccination Humoral Response to SARS-CoV-2 in Polish Long-Term Care Facility Residents: Associations with COVID-19 Clinical Course and Comorbidities
by Justyna Brodowicz, Piotr Heczko, Estera Jachowicz-Matczak, Mateusz Gajda, Katarzyna Gawlik, Dorota Pawlica-Gosiewska, Bogdan Solnica and Jadwiga Wójkowska-Mach
Infect. Dis. Rep. 2025, 17(4), 89; https://doi.org/10.3390/idr17040089 - 24 Jul 2025
Viewed by 213
Abstract
Background: Vaccination effectively reduces the risk of infection, including COVID-19 yet older adults often receive insufficient attention despite their increased vulnerability. The study aimed to correlate serological results with underlying conditions, vaccination status, and COVID-19 history. Methods: This non-interventional, multicenter study aimed to [...] Read more.
Background: Vaccination effectively reduces the risk of infection, including COVID-19 yet older adults often receive insufficient attention despite their increased vulnerability. The study aimed to correlate serological results with underlying conditions, vaccination status, and COVID-19 history. Methods: This non-interventional, multicenter study aimed to assess vaccination coverage and SARS-CoV-2 antibody levels among residents of eight long-term care facilities (LTCFs) in Southern Poland. Data collection took place between January and June 2022, with 429 participants recruited based on their ability to provide informed consent and their residency in LTCFs. Sociodemographic data, medical history, and COVID-19-related information—including infection history and vaccination status—were collected through surveys. Blood samples were obtained for serological testing using enzyme-linked immunosorbent assays (ELISA) to detect anti-SARS-CoV-2 antibodies. Statistical analysis, including Spearman’s correlation, revealed significant associations between antibody levels and vaccination status, as well as between RT-PCR-confirmed COVID-19 infections and higher antibody titers. Results: Among the seven different qualitative serological, only the Anti-SARS-CoV-2 NCP (IgG) and Anti-SARS-CoV-2 (IgA) tests showed a positive correlation with the Anti-SARS-CoV-2 QuantiVac (IgG) test, which was used as a comparator. A weak correlation was noted with the age of the residents. Conclusions: Our findings suggest that vaccination positively influences antibody responses, underscoring the importance of immunization among LTCF residents. Additionally, certain comorbidities—such as degenerative joint disease and diabetes—showed weak correlations with higher antibody levels. This study provides valuable insights into the humoral immune response to COVID-19 in vulnerable populations residing in LTCFs. Full article
Show Figures

Figure 1

17 pages, 5711 KiB  
Article
Impact of High-Temperature Exposure on Reinforced Concrete Structures Supported by Steel Ring-Shaped Shear Connectors
by Atsushi Suzuki, Runze Yang and Yoshihiro Kimura
Buildings 2025, 15(15), 2626; https://doi.org/10.3390/buildings15152626 - 24 Jul 2025
Viewed by 283
Abstract
Ensuring the structural integrity of reinforced concrete (RC) components in nuclear facilities exposed to extreme conditions is essential for safe decommissioning. This study investigates the impact of high-temperature exposure on RC pedestal structures supported by steel ring-shaped shear connectors—critical elements for maintaining vertical [...] Read more.
Ensuring the structural integrity of reinforced concrete (RC) components in nuclear facilities exposed to extreme conditions is essential for safe decommissioning. This study investigates the impact of high-temperature exposure on RC pedestal structures supported by steel ring-shaped shear connectors—critical elements for maintaining vertical and lateral load paths in containment systems. Scaled-down cyclic loading tests were performed on pedestal specimens with and without prior thermal exposure, simulating post-accident conditions observed at a damaged nuclear power plant. Experimental results show that thermal degradation significantly reduces lateral stiffness, with failure mechanisms concentrating at the interface between the concrete and the embedded steel skirt. Complementary finite element analyses, incorporating temperature-dependent material degradation, highlight the crucial role of load redistribution to steel components when concrete strength is compromised. Parametric studies reveal that while geometric variations in the inner skirt have limited influence, thermal history is the dominant factor affecting vertical capacity. Notably, even with substantial section loss in the concrete, the steel inner skirt maintained considerable load-bearing capacity. This study establishes a validated analytical framework for assessing structural performance under extreme conditions, offering critical insights for risk evaluation and retrofit strategies in the context of nuclear facility decommissioning. Full article
(This article belongs to the Section Building Structures)
Show Figures

Figure 1

14 pages, 614 KiB  
Article
“Eyes on the Street” as a Conditioning Factor for Street Safety Comprehension: Quito as a Case Study
by Nuria Vidal-Domper, Susana Herrero-Olarte, Gioconda Ramos and Marta Benages-Albert
Buildings 2025, 15(15), 2590; https://doi.org/10.3390/buildings15152590 - 22 Jul 2025
Viewed by 496
Abstract
The presence of people has a complex relationship with public safety—while it is often associated with increased natural surveillance, it can also attract specific types of crime under certain urban conditions. This exploratory study examines this dual relationship by integrating Jane Jacobs’s urban [...] Read more.
The presence of people has a complex relationship with public safety—while it is often associated with increased natural surveillance, it can also attract specific types of crime under certain urban conditions. This exploratory study examines this dual relationship by integrating Jane Jacobs’s urban theories and the principles derived from them in Quito, Ecuador. Anchored in Jacobs’s concept of “eyes on the street,” this research assesses four morphological dimensions—density, land use mixture, contact opportunity, and accessibility through nine specific indicators. A binary logistic regression model is used to examine how these features relate to the incidence of street robberies against individuals. The findings indicate that urban form characteristics that foster “eyes on the street”—such as higher population density and a mix of commercial and residential uses—show statistically significant associations with lower rates of street robbery. However, other indicators of “eyes on the street”—such as larger block sizes, proximity to public transport stations, greater street lighting, and a higher balance between residential and non-residential land uses—correlate with increased crime rates. Some indicators, such as population density, block size, and distance to public transport stations, show statistically significant relationships, though the practical effect size compared to residential/non-residential balance, commercial and facility mix, and street lighting is modest. These results underscore the importance of contextualizing Jacobs’s frameworks and offer a novel contribution to the literature by empirically testing morphological indicators promoting the presence of people against actual crime data. Full article
Show Figures

Figure 1

23 pages, 2079 KiB  
Article
Offshore Energy Island for Sustainable Water Desalination—Case Study of KSA
by Muhnad Almasoudi, Hassan Hemida and Soroosh Sharifi
Sustainability 2025, 17(14), 6498; https://doi.org/10.3390/su17146498 - 16 Jul 2025
Viewed by 452
Abstract
This study identifies the optimal location for an offshore energy island to supply sustainable power to desalination plants along the Red Sea coast. As demand for clean energy in water production grows, integrating renewables into desalination systems becomes increasingly essential. A decision-making framework [...] Read more.
This study identifies the optimal location for an offshore energy island to supply sustainable power to desalination plants along the Red Sea coast. As demand for clean energy in water production grows, integrating renewables into desalination systems becomes increasingly essential. A decision-making framework was developed to assess site feasibility based on renewable energy potential (solar, wind, and wave), marine traffic, site suitability, planned developments, and proximity to desalination facilities. Data was sourced from platforms such as Windguru and RETScreen, and spatial analysis was conducted using Inverse Distance Weighting (IDW) and Multi-Criteria Decision Analysis (MCDA). Results indicate that the central Red Sea region offers the most favorable conditions, combining high renewable resource availability with existing infrastructure. The estimated regional desalination energy demand of 2.1 million kW can be met using available renewable sources. Integrating these sources is expected to reduce local CO2 emissions by up to 43.17% and global desalination-related emissions by 9.5%. Spatial constraints for offshore installations were also identified, with land-based solar energy proposed as a complementary solution. The study underscores the need for further research into wave energy potential in the Red Sea, due to limited real-time data and the absence of a dedicated wave energy atlas. Full article
Show Figures

Figure 1

21 pages, 6897 KiB  
Article
Performance Analysis of HVDC Operational Control Strategies for Supplying Offshore Oil Platforms
by Alex Reis, José Carlos Oliveira, Carlos Alberto Villegas Guerrero, Johnny Orozco Nivelo, Lúcio José da Motta, Marcos Rogério de Paula Júnior, José Maria de Carvalho Filho, Vinicius Zimmermann Silva, Carlos Andre Carreiro Cavaliere and José Mauro Teixeira Marinho
Energies 2025, 18(14), 3733; https://doi.org/10.3390/en18143733 - 15 Jul 2025
Viewed by 218
Abstract
Driven by the environmental benefits associated with reduced greenhouse gas emissions, oil companies have intensified research efforts into reassessing the strategies used to meet the electrical demands of offshore production platforms. Among the various alternatives available, the deployment of onshore–offshore interconnections via High-Voltage [...] Read more.
Driven by the environmental benefits associated with reduced greenhouse gas emissions, oil companies have intensified research efforts into reassessing the strategies used to meet the electrical demands of offshore production platforms. Among the various alternatives available, the deployment of onshore–offshore interconnections via High-Voltage Direct Current (HVDC) transmission systems has emerged as a promising solution, offering both economic and operational advantages. In addition to reliably meeting the electrical demand of offshore facilities, this approach enables enhanced operational flexibility due to the advanced control and regulation capabilities inherent to HVDC converter stations. Based on the use of interconnection through an HVDC link, aiming to evaluate the operation of the electrical system as a whole, this study focuses on evaluating dynamic events using the PSCAD software version 5.0.2 to analyze the direct online starting of a large induction motor and the sudden loss of a local synchronous generating unit. The simulation results are then analyzed to assess the effectiveness of both Grid-Following (GFL) and Grid-Forming (GFM) control strategies for the converters, while the synchronous generators are evaluated under both voltage regulation and constant power factor control operation, with a particular focus on system stability and restoration of normal operating conditions in the sequence of events. Full article
(This article belongs to the Special Issue Advanced Electric Power Systems, 2nd Edition)
Show Figures

Figure 1

20 pages, 5384 KiB  
Article
Integrated Water Resources Management in Response to Rainfall Change: A Runoff-Based Approach for Mixed Land-Use Catchments
by Jinsun Kim and Ok Yeon Choi
Environments 2025, 12(7), 241; https://doi.org/10.3390/environments12070241 - 14 Jul 2025
Viewed by 533
Abstract
The U.S. Environmental Protection Agency (EPA) developed the concept of Water Quality Volume (WQv) as a Best Management Practice (BMP) to treat the first 25.4 mm of rainfall in urban areas, aiming to capture approximately 90% of annual runoff. However, applying this urban-based [...] Read more.
The U.S. Environmental Protection Agency (EPA) developed the concept of Water Quality Volume (WQv) as a Best Management Practice (BMP) to treat the first 25.4 mm of rainfall in urban areas, aiming to capture approximately 90% of annual runoff. However, applying this urban-based standard—designed for areas with over 50% imperviousness—to rural regions with higher infiltration and pervious surfaces may result in overestimated facility capacities. In Korea, a uniform WQv criterion of 5 mm is applied nationwide, regardless of land use or hydrological conditions. This study examines the suitability of this 5 mm standard in rural catchments using the Hydrological Simulation Program–Fortran (HSPF). Eight sub-watersheds in the target area were simulated under varying cumulative runoff depths (1–10 mm) to assess pollutant loads and runoff characteristics. First-flush effects were most evident below 5 mm, with variation depending on land cover. Nature-based treatment systems for constructed wetlands were modeled for each sub-watershed, and their effectiveness was evaluated using Flow Duration Curves (FDCs) and Load Duration Curves (LDCs). The findings suggest that the uniform 5 mm WQv criterion may result in overdesign in rural watersheds and highlight the need for region-specific standards that consider local land-use and hydrological variability. Full article
(This article belongs to the Special Issue Monitoring of Contaminated Water and Soil)
Show Figures

Figure 1

17 pages, 639 KiB  
Review
Energy Efficiency Measurement Method and Thermal Environment in Data Centers—A Literature Review
by Zaki Ghifari Muhamad Setyo, Hom Bahadur Rijal, Naja Aqilah and Norhayati Abdullah
Energies 2025, 18(14), 3689; https://doi.org/10.3390/en18143689 - 12 Jul 2025
Viewed by 501
Abstract
The increase in data center facilities has led to higher energy consumption and a larger carbon footprint, prompting improvements in thermal environments for energy efficiency and server lifespan. Existing literature studies often overlook categorizing equipment for power usage effectiveness (PUE), addressing power efficiency [...] Read more.
The increase in data center facilities has led to higher energy consumption and a larger carbon footprint, prompting improvements in thermal environments for energy efficiency and server lifespan. Existing literature studies often overlook categorizing equipment for power usage effectiveness (PUE), addressing power efficiency measurement limitations and employee thermal comfort. These issues are addressed through an investigation of the PUE metric, a comparative analysis of various data center types and their respective cooling conditions, an evaluation of PUE in relation to established thermal standards and an assessment of employee thermal comfort based on defined criteria. Thirty-nine papers and ten websites were reviewed. The results indicated an average information technology (IT) power usage of 44.8% and a PUE of 2.23, which reflects average efficiency, while passive cooling was found to be more applicable to larger-scale data centers, such as Hyperscale or Colocation facilities. Additionally, indoor air temperatures averaged 16.5 °C with 19% relative humidity, remaining within the allowable range defined by ASHRAE standards, although employee thermal comfort remains an underexplored area in existing data center research. These findings highlight the necessity for clearer standards on power metrics, comprehensive thermal guidelines and the exploration of alternative methods for power metrics and cooling solutions. Full article
(This article belongs to the Section G: Energy and Buildings)
Show Figures

Figure 1

24 pages, 2885 KiB  
Article
Life Cycle Approach to Shopping Mall Redevelopment: A Model for Service Life Design
by Jasmina Tamburić, Vladan Nikolić, Dragoslav Stojić and Olivera Nikolić
Appl. Sci. 2025, 15(13), 7509; https://doi.org/10.3390/app15137509 - 4 Jul 2025
Viewed by 469
Abstract
This study investigates the enhancement of condition and the extension of service life in architectural structures of shopping malls through the application of a hybrid methodological framework that integrates Life Cycle Assessment (LCA) and Service Life Planning (SLP). Thisresearch identifies key parameters related [...] Read more.
This study investigates the enhancement of condition and the extension of service life in architectural structures of shopping malls through the application of a hybrid methodological framework that integrates Life Cycle Assessment (LCA) and Service Life Planning (SLP). Thisresearch identifies key parameters related to physical performance, sustainability indicators, and functional characteristics of architectural systems that are subject to deterioration and shifting market conditions during the operational phase. The methodology encompasses a theoretical synthesis of LCA/SLP principles and advances in modeling for both the integrated design of new facilities and the monitoring and renewal of existing ones—from data collection and early-stage planning, through construction, use, and maintenance, to end-of-life phases. A second component of the model focuses on quantitative assessment and condition forecasting, based on Markov chain modeling, applied to the case study of the “Deva 1” shopping mall in Serbia. The results demonstrate the model’s ability to correlate physical condition indices with predictive service life scenarios.This study further contributes by integrating time-dependent impact categories, usage profiles, and planning parameters into a unified evaluation matrix, which can be applied to the development and improvement of systems aimed at enhancing the structural, functional, esthetic, and indirectly economic value of shopping mall buildings throughout their entire life cycle—from an architectural perspective. Full article
Show Figures

Figure 1

Back to TopTop