Sign in to use this feature.

Years

Between: -

Subjects

remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline

Journals

Article Types

Countries / Regions

Search Results (141)

Search Parameters:
Keywords = dental acid etching

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
16 pages, 19147 KiB  
Article
Surface Assessment of a Novel Acid-Etching Solution on CAD/CAM Dental Ceramics
by Fabio Andretti, Carlos A. Jurado, Mark Antal, Alfredo I. Hernandez, Silvia Rojas-Rueda, Franklin Garcia-Godoy, Brian R. Morrow and Hamid Nurrohman
Biomimetics 2025, 10(8), 508; https://doi.org/10.3390/biomimetics10080508 - 4 Aug 2025
Viewed by 47
Abstract
Background: This study investigated a new multi-acid-etching formulation for zirconia ceramics, containing hydrochloric, hydrofluoric, nitric, orthophosphoric, and sulfuric acids. The solution was tested on polycrystalline (5Y-TZP zirconia), lithium disilicate, hybrid ceramic, and feldspathic porcelain to assess compatibility, etching selectivity, and surface conditioning. Methods: [...] Read more.
Background: This study investigated a new multi-acid-etching formulation for zirconia ceramics, containing hydrochloric, hydrofluoric, nitric, orthophosphoric, and sulfuric acids. The solution was tested on polycrystalline (5Y-TZP zirconia), lithium disilicate, hybrid ceramic, and feldspathic porcelain to assess compatibility, etching selectivity, and surface conditioning. Methods: Two-hundred-and-forty CAD/CAM specimens were etched for 20 s, 60 s, 30 min, or 1 h, and their surface roughness and etching patterns ware evaluated using 3D optical profilometry and scanning electron microscopy (SEM). Results: A positive correlation was observed between etching time and surface roughness (Ra values). The most pronounced changes were observed in lithium disilicate and feldspathic porcelain, with Ra values increasing from 0.733 ± 0.082 µm (Group 5) to 1.295 ± 0.123 µm (Group 8), and from 0.902 ± 0.102 µm (Group 13) to 1.480 ± 0.096 µm (Group 16), respectively. Zirconia increased from 0.181 ± 0.043 µm (Group 1) to 0.371 ± 0.074 µm (Group 4), and the hybrid ceramic from 0.053 ± 0.008 µm (Group 9) to 0.099 ± 0.016 µm (Group 12). Two-way ANOVA revealed significant effects of material and etching time, as well as a significant interaction between the two factors (p < 0.001). SEM observation revealed non-selective etching pattern for the lithium disilicate groups, indicating a risk of over-etching. Conclusions: The tested etching solution increased surface roughness, especially for the lithium disilicate and feldspathic porcelain specimens. In zirconia, one-hour etching improved surface characteristics with minimal observable damage. However, additional studies are necessary to validate the mechanical stability and bond effectives of this approach. Full article
(This article belongs to the Special Issue Biomimetic Bonded Restorations for Dental Applications)
Show Figures

Figure 1

16 pages, 2558 KiB  
Article
Bonding Orthodontic Attachments to 3D-Printed Photosensitive Definitive Resin: An In Vitro Study
by Omaika Victoria Criollo-Barrios, Carlos Roberto Luna-Domínguez, Carlos Alberto Luna-Lara, Ricardo de Jesus Figueroa-López, Ronaldo Câmara Cozza and Jorge Humberto Luna-Domínguez
Dent. J. 2025, 13(8), 341; https://doi.org/10.3390/dj13080341 - 24 Jul 2025
Viewed by 243
Abstract
Background/Objectives: The increasing clinical integration of 3D-printed definitive resins requires a comprehensive understanding of their physicochemical properties and adhesive behavior. However, there is limited evidence regarding the optimal surface treatment and bonding strategies for clear aligner composite attachments on these materials. This [...] Read more.
Background/Objectives: The increasing clinical integration of 3D-printed definitive resins requires a comprehensive understanding of their physicochemical properties and adhesive behavior. However, there is limited evidence regarding the optimal surface treatment and bonding strategies for clear aligner composite attachments on these materials. This study aimed to characterize a 3D-printed definitive resin, evaluate the effects of surface treatments on its surface topography, and compare the shear bond strength (SBS) of the bonded attachments using different adhesive systems, both before and after thermocycling. Methods: A total of 120 rectangular specimens were fabricated from a 3D printed dental resin (Crowntec®, SAREMCO Dental AG—Mexico City, Mexico). For physicochemical characterization, six samples underwent scanning electron microscopy/energy-dispersive spectroscopy, X-ray diffraction, and thermogravimetric analysis. To evaluate surface topography, 42 polished specimens were assigned to three groups: untreated (control), etched with 4% hydrofluoric acid (HFA), or sandblasted with 50 µm Al2O3 (AA). Each group was subdivided for SEM observation and surface roughness (Ra) measurement. For SBS testing, 72 additional samples received the same surface treatments and were further subdivided according to the adhesive system: Transbond™ XT Primer (TXT) or Single Bond Universal (SBU). Results: The AA group showed the highest Ra (2.21 ± 0.30 µm), followed by HFA (0.81 ± 0.20 µm) and control (0.07 ± 0.30 µm) (p < 0.001). The highest SBS was observed in the AA + SBU group, followed by AA + TXT. Conclusions: Sandblasting with Al2O3 particles, combined with a universal adhesive, significantly improved bond strength, suggesting a viable protocol for 3D printed definitive composites in aligner attachment applications. Full article
(This article belongs to the Section Dental Materials)
Show Figures

Figure 1

15 pages, 2093 KiB  
Article
Different Innovative Laser Implants Characteristics Histomorphometric and SEM-EDX Comparison for In Vivo Applications
by Filiberto Mastrangelo, Marco Cicciù, Raimondo Quaresima and Antonio Scarano
Materials 2025, 18(13), 3165; https://doi.org/10.3390/ma18133165 - 3 Jul 2025
Viewed by 320
Abstract
Objectives: In the animal model, we aim to evaluate the bone behavior in two innovative and different laser-treated (L1–L2) titanium implants compared to sandblasted and acid-etched (SBAE) used as control. Materials and Methods: A total of twenty-seven dental implants (8.5 × 3.3 mm) [...] Read more.
Objectives: In the animal model, we aim to evaluate the bone behavior in two innovative and different laser-treated (L1–L2) titanium implants compared to sandblasted and acid-etched (SBAE) used as control. Materials and Methods: A total of twenty-seven dental implants (8.5 × 3.3 mm) used for the study (Sweden & Martina, Due Carraie Padova-Italy) were placed in three Pelibuey female sheep. Implant surface profilometric, contact angle and EDX analysis were detected. After 15, 30 and 90 days, histological, histomorphometric, SEM-EDX analysis and Bone-to-implant Contact (BIC), Dynamic Osseointegration Index (DOI) and Bone Quality Index (BQI) (as Calcium and Phosphorous atomic percentages ratio) were performed. Results: All surfaces showed relevant profilometric and wettability differences. After 15 days, BIC15 showed great differences in L2 (42.1 ± 2.6) compared to L1 (5.2 ± 3.1) and SBAE (23.3 ± 3.9) as well as after 30 days (L2 (82.4 ± 2.2), L1 (56.2 ± 1.3) and SBAE (77.3 ± 0.4)). After 90 days, relevant lower BIC90 values were detected in L1 (68.4 ± 0.2) compared to L2 (86.4 ± 0.1) and SBAE (86.2 ± 0.6). The DOI showed higher rates of bone growth in L2 after 15 (DOI15 = 2.81) and 30 days (DOI30 = 2.83), compared to L1 (DOI15 = 0.38, DOI30 = 3.40) and SBAE (DOI15 = 1.55, DOI30 = 2.58). The DOI90 drastic slowdown in SBAE (0.96), L1 (0.76), and L2 (0.95) confirmed the Early Osseointegration (EO) as a crucial phase. Moreover, before loading, the lower global BQI in L1 (Ca 44.43 ± 0.08–P 46.14 ± 5.15) and SBAE (Ca 45.31 ± 2.08–P 48.28 ± 1.12) compared to L2 (Ca 79.81 ± 2.08–P 81.85 ± 3.14) allows to assert that osseointegration process and bone healing could not be considered complete if compared to the native bone. Conclusions: The BIC, DOI, and BQI results showed that osseointegration is a dynamic process, confirming the crucial role of surface characteristics able to influence it, especially the early osseointegration (EO) phase. The short-time L2 implants’ higher bone quantity and quality results, compared to L1 and SBAE, suggested the fundamental role of this innovative laser-obtained surface in “secondary stability” and predictable long-term clinical outcomes. Full article
(This article belongs to the Special Issue Dental Biomaterials: Synthesis, Characterization, and Applications)
Show Figures

Figure 1

22 pages, 8327 KiB  
Article
Surface Evaluation of a Novel Acid-Etching Solution for Zirconia and Lithium Disilicate
by Clint Conner, Fabio Andretti, Alfredo I. Hernandez, Silvia Rojas-Rueda, Francisco X. Azpiazu-Flores, Brian R. Morrow, Franklin Garcia-Godoy, Carlos A. Jurado and Abdulrahman Alshabib
Materials 2025, 18(12), 2912; https://doi.org/10.3390/ma18122912 - 19 Jun 2025
Cited by 1 | Viewed by 443
Abstract
The current investigation evaluated a novel acid-etching solution containing hydrochloric acid (HCl), hydrofluoric acid (HF), nitric acid (HNO3), orthophosphoric acid (H3PO4), and sulfuric acid (H2SO4) designed for etching zirconia ceramics. Achieving reliable bonding [...] Read more.
The current investigation evaluated a novel acid-etching solution containing hydrochloric acid (HCl), hydrofluoric acid (HF), nitric acid (HNO3), orthophosphoric acid (H3PO4), and sulfuric acid (H2SO4) designed for etching zirconia ceramics. Achieving reliable bonding to zirconia is challenging due to its chemical inertia, unlike lithium disilicate, which can be effectively conditioned with HF etching. One hundred and twenty specimens of zirconia and lithium disilicate underwent etching with the experimental solution for six different durations: control, 20 s, 60 s, 5 min, 30 min, and 1 h. Surface roughness was assessed using 3D optical profilometry and scanning electron microscopy (SEM). The roughness of both materials increased with etching time; however, lithium disilicate demonstrated a significantly greater response, with Ra values rising from 0.18 µm (control) to 1.26 µm (1 h), while zirconia increased from 0.21 µm to 0.60 µm. ANOVA revealed significant effects depending on the ceramic type, time, and their interaction (p < 0.001). SEM images revealed non-selective etching of lithium disilicate, suggesting potential over-etching. The novel acid-etching solution improved surface roughness, especially in lithium disilicate ceramics. An application duration of one hour appears optimal for zirconia, improving surface characteristics while reducing damage; however, further research is required to assess its clinical safety and long-term effects on the mechanical properties of this dental ceramic. Full article
(This article belongs to the Special Issue Characteristics of Dental Ceramics)
Show Figures

Figure 1

12 pages, 1202 KiB  
Article
Comparative Evaluation of Dental Clinical Surface Treatments for Polyetheretherketone with Airborne-Particle Abrasion, Hydrofluoric Acid Etching, and Handheld Nonthermal Plasma Activation on Long-Term Bond Performance
by Szu-Yu Lai, Szu-I Lin, Chia-Wei Chang, Yi-Rou Shen, Yuichi Mine, Zih-Chan Lin, Mei-Ling Fang, Chia-Chih Sung, Chien-Fu Tseng, Tzu-Yu Peng and Chiang-Wen Lee
Polymers 2025, 17(11), 1448; https://doi.org/10.3390/polym17111448 - 23 May 2025
Viewed by 571
Abstract
Polyaryletherketone (PAEK) materials, including polyetheretherketone (PEEK) and polyetherketoneketone (PEKK), possess excellent mechanical properties and biocompatibility; however, their inherently low surface energy limits effective bonding with resin cements. This study investigated the effects of hydrofluoric acid (HF) etching and handheld nonthermal plasma (HNP) treatment [...] Read more.
Polyaryletherketone (PAEK) materials, including polyetheretherketone (PEEK) and polyetherketoneketone (PEKK), possess excellent mechanical properties and biocompatibility; however, their inherently low surface energy limits effective bonding with resin cements. This study investigated the effects of hydrofluoric acid (HF) etching and handheld nonthermal plasma (HNP) treatment on enhancing the adhesive performance of PAEK surfaces. Disk-shaped PEEK (BP) and PEKK (PK) specimens were divided into four groups: APA (airborne-particle abrasion), PLA (nonthermal plasma treatment), LHF (5.0% HF), and HHF (9.5% HF). Surface characterization was performed using a thermal field emission scanning electron microscope (FE-SEM). Surface wettability was evaluated using contact angle goniometry. Cytotoxicity was evaluated using HGF-1 cells exposed to conditioned media and analyzed via PrestoBlue assays. Shear bond strength (SBS) was measured after three aging conditions—NT (no aging), TC (thermocycling), and HA (highly accelerated aging)—using a light-curing resin cement. Failure modes were categorized, and statistical analysis was performed using one-way and two-way ANOVA with Tukey’s HSD test (α = 0.05). Different surface treatments did not affect surface characterization. PLA treatment significantly improved surface wettability, resulting in the lowest contact angles among all groups, followed by HF etching (HHF > LHF), while APA showed the poorest hydrophilicity. Across all treatments, PK exhibited better wettability than BP. Cytotoxicity results confirmed that all surface treatments were nontoxic to HGF-1 cells, indicating favorable biocompatibility. SBS testing demonstrated that PLA-treated specimens achieved the highest and most stable bond strength across all aging conditions. Although HF-treated groups exhibited lower bond strength overall, BP samples treated with HF showed relatively less reduction following aging. Failure mode analysis revealed a shift from mixture and cohesive failures in the NT aging condition to predominantly adhesive failures after TC and HA aging conditions. Notably, the PLA-treated groups retained mixture failure patterns even after aging, suggesting improved interfacial durability. Among the tested methods, PLA treatment was the most effective strategy, enhancing surface wettability, bond strength, and aging resistance without compromising biocompatibility. In summary, the PLA demonstrated the greatest clinical potential for improving the adhesive performance of PAEK when used with light-curing resin cements. Full article
(This article belongs to the Special Issue Polymers and Polymer Composites for Dental Application)
Show Figures

Figure 1

23 pages, 5498 KiB  
Article
A New Preclinical Surgical Model for the Assessment of Dental Implant Tissue Integration
by Ryan Noh, Nahrain Warda, Charles Tremblay and John E. Davies
Surgeries 2025, 6(2), 36; https://doi.org/10.3390/surgeries6020036 - 17 Apr 2025
Cited by 1 | Viewed by 1036
Abstract
Background/Objectives: The structural integrity and strength of the transgingival soft tissue seal around dental implant surfaces remain critical challenges. Therefore, animal models should include all three implant/tissue interfaces: bone, connective tissue, and epithelium. Thus, we sought to explore the rabbit mandibular diastema as [...] Read more.
Background/Objectives: The structural integrity and strength of the transgingival soft tissue seal around dental implant surfaces remain critical challenges. Therefore, animal models should include all three implant/tissue interfaces: bone, connective tissue, and epithelium. Thus, we sought to explore the rabbit mandibular diastema as a site for candidate intra-oral implant placement. Methods: Ninety-six custom mini-implants (with one of four different surfaces: machined, acid-etched, and with or without a nanotube coating) made from titanium 6/4 alloy were placed in the mandibular diastemas of twenty-four 16-week-old New Zealand white rabbits, with the implant collar above the alveolar crest. After 7, 21, and 42 days, the bony and connective tissue/implant interfaces were examined by light and scanning electron microscopy (SEM). Results: Of ninety-six implants, eight implants were found exposed to the oral cavity, with no evidence of soft tissue inflammation, suggesting that transmucosal implant placement would have been feasible. No significant differences were observed in collagen fiber orientation and fibrous tissue thickness by polarized light microscopy. However, SEM images showed that at all three time points, topographically complex nanotube surfaces had a profound effect on soft tissue peri-implant deposition, although functionally oriented collagen fibers were not identified attached to the implant surface. These surfaces also showed reparative peri-implant bone in the collar region. An intramembranous form of de novo bone formation was observed, together with tartrate-resistant acid-phosphatase-positive osteoclasts and multinucleate giant cells in the peri-implant endosseous compartment. Conclusions: Our results demonstrate that the rabbit mandibular diastema provides an intra-oral method of implant placement without the necessity of an extra-oral approach, tooth extractions, or bone augmentation procedures. Furthermore, given that three implant tissue interfaces can potentially be studied (bone, connective tissue, and epithelium) this model provides advantages over more traditional implant placement sites in the appendicular skeleton. Full article
Show Figures

Graphical abstract

16 pages, 8151 KiB  
Article
Comparative Study of Acid Etching and SLA Surface Modification for Titanium Implants
by Gabriel M. Vieira, Tatiane C. S. Almeida, Fernanda P. Oliveira, Patrícia C. Azzi, Caio F. Rodrigues, Rafael L. Souza, Samyra Maria S. N. Lacerda, Frederico S. Lages and Maximiliano D. Martins
Materials 2025, 18(7), 1632; https://doi.org/10.3390/ma18071632 - 3 Apr 2025
Cited by 2 | Viewed by 777
Abstract
The dust generated during the sandblasting process of the sandblasted and acid-etched (SLA) method, commonly used to treat the surface of Ti dental implants, poses significant challenges in maintaining a clean manufacturing environment and ensuring safe working conditions. Nevertheless, surface modification remains crucial [...] Read more.
The dust generated during the sandblasting process of the sandblasted and acid-etched (SLA) method, commonly used to treat the surface of Ti dental implants, poses significant challenges in maintaining a clean manufacturing environment and ensuring safe working conditions. Nevertheless, surface modification remains crucial for improved performance of Ti dental implants. To address this problem and propose a clean and simple surface modification process to potentially replace SLA modification, this study aimed to characterize the surfaces of commercially pure Ti (cp-Ti) samples treated by acid etching and compare them with SLA-treated samples in terms of surface roughness (Rq), wettability (assessed through contact angle measurements), mineralized matrix deposition (evaluated through simulated body fluid [SBF] soaking), cell viability, cell differentiation (assessed based on alkaline phosphatase activity), and mineralization (assessed using MTT assay). Acid-etched surfaces exhibited nano- and micro-roughness and higher hydrophilicity than SLA surfaces, which is conducive to forming a highly bioactive TiO2 surface. Moreover, acid-etched samples exhibited earlier hydroxyapatite deposition after SBF soaking than SLA samples. Furthermore, the acid-etched surfaces were nontoxic and displayed significantly higher cell viability and differentiation after seven days than SLA surfaces. These findings suggest that acid etching is a viable alternative to the SLA method, likely offering superior surface bioactivity and biocompatibility. Full article
(This article belongs to the Special Issue Surface Modification of Materials for Multifunctional Applications)
Show Figures

Figure 1

20 pages, 2470 KiB  
Review
Improving the Clinical Performance of Dental Implants Through Advanced Surface Treatments: The Case of Ti and ZrO2 Coatings
by Mohamed Aissi, Qanita Tayyaba, Azzedine Er-Ramly, Hendra Hermawan and Nadia Merzouk
Metals 2025, 15(3), 320; https://doi.org/10.3390/met15030320 - 14 Mar 2025
Cited by 1 | Viewed by 1199
Abstract
This review summarizes the development of surface treatments applied to dental implants with the aim of improving their clinical performance. It covers the advancement of various techniques, from the conventional to the more advanced ones. Among the recent advancements, surface texturing has enabled [...] Read more.
This review summarizes the development of surface treatments applied to dental implants with the aim of improving their clinical performance. It covers the advancement of various techniques, from the conventional to the more advanced ones. Among the recent advancements, surface texturing has enabled atomic and structural modifications of implant surfaces at the micro- and nanoscales, improving tissue–material interactions. Acid etching and atomic layer deposition applied onto implant surfaces results in optimized osseointegration by stimulating the deposition and proliferation of osteoblasts and fibroblasts. The atomic layer deposition of TiO2, ZnO, ZrO2, and CaCO3 has proven effective in improving osseointegration and tackling corrosion. Corrosion is still an important issue, whereby metals released from titanium implants and their associated degradation products cause local and systemic side effects, leaving a wide avenue for future research. The development of hybrid dental implants is envisaged through new materials and technologies, such as additive manufacturing, which may play a critical role in the fabrication of patient-specific implants with tailored nano-topography capable of enhancing such properties as antibacterial activity and osseointegration. Full article
(This article belongs to the Special Issue Advanced Biomedical Materials (2nd Edition))
Show Figures

Figure 1

15 pages, 5200 KiB  
Article
Designing Superhydrophilic 3D Porous Surfaces on Polyetherketoneketone Surfaces to Promote Biocompatibility
by Hui-Ching Lin, Chiang-Sang Chen, Kai-Yi Lin, Ya-Lin Huang, Hao-Hsiang Hsu, Yu-Lin Kuo, Wei-Cheng Chen and Her-Hsiung Huang
J. Funct. Biomater. 2025, 16(3), 106; https://doi.org/10.3390/jfb16030106 - 14 Mar 2025
Viewed by 1025
Abstract
Polyetherketoneketone (PEKK) exhibits satisfactory mechanical properties and biocompatibility, with an elastic modulus closely resembling that of natural bone. This property reduces the stress-shielding effect associated with bone implants. However, the biological inertness of the PEKK surface remains a significant limitation for its application [...] Read more.
Polyetherketoneketone (PEKK) exhibits satisfactory mechanical properties and biocompatibility, with an elastic modulus closely resembling that of natural bone. This property reduces the stress-shielding effect associated with bone implants. However, the biological inertness of the PEKK surface remains a significant limitation for its application in bone tissue engineering. The objective of this study was to create a superhydrophilic 3D porous structure on the surface of PEKK to enhance biocompatibility, in terms of vascularization and bone remodeling. A combination of mechanical, chemical, and physical surface treatments was employed to modify the PEKK surface. Initially, mechanical sandblasting was used to create a rough surface to promote mechanical interlocking with bone tissue. Subsequently, chemical acid etching and physical low-temperature atmospheric plasma cleaning were applied to develop a superhydrophilic 3D porous surface. The modified surfaces were characterized for morphology, roughness, hydrophilicity, and functional groups. Cellular responses, including vascularization and bone remodeling, were evaluated to assess the potential for improved biocompatibility. The combination of acid etching and low-temperature atmospheric plasma cleaning, with or without prior sandblasting, successfully created a superhydrophilic 3D porous structure on the PEKK surface. This modified surface enhanced the tube formation in human umbilical vein endothelial cells. It also promoted the adhesion and mineralization of human bone marrow mesenchymal stem cells and slightly reduced tartrate-resistant acid phosphatase expression and F-actin ring size in mouse macrophage cells. This study introduces an innovative and effective surface modification strategy for PEKK surface, combining mechanical, chemical, and physical treatments to enhance biocompatibility. The modified PEKK surface promotes angiogenic and osteogenic responses while slightly inhibiting osteoclastic activity, making it a potential alternative for dental and orthopedic PEKK implant applications. Full article
(This article belongs to the Collection Feature Papers in Bone Biomaterials)
Show Figures

Figure 1

43 pages, 1876 KiB  
Review
Evolution of Dental Resin Adhesives—A Comprehensive Review
by Waad Khalid Alomran, Mohammed Zahedul Islam Nizami, Hockin H. K. Xu and Jirun Sun
J. Funct. Biomater. 2025, 16(3), 104; https://doi.org/10.3390/jfb16030104 - 14 Mar 2025
Cited by 4 | Viewed by 3503
Abstract
This comprehensive review of dental resin adhesives explores their historical development, key components, recent innovations, and potential future directions, highlighting a dynamic and continually advancing field. From Buonocore’s breakthrough acid-etching technique and Bowen’s pioneering dental resin invention, successive generations of clinicians and scientists [...] Read more.
This comprehensive review of dental resin adhesives explores their historical development, key components, recent innovations, and potential future directions, highlighting a dynamic and continually advancing field. From Buonocore’s breakthrough acid-etching technique and Bowen’s pioneering dental resin invention, successive generations of clinicians and scientists have pushed forward the technological and materials development for secure bonding, while preserving dental tissues. The review discusses the substantial advances in improving adhesive reliability, enabling more conservative treatment approaches. It also delves into enhancing fundamental adhesive components and their synergistic combinations. Recent innovations, including biostable and functional resins, nanotechnology, and bioactive components, address persistent challenges such as durability, antimicrobial efficacy, and therapeutic functionality. Emerging technologies, such as digital dentistry, artificial intelligence, and bioinspired adhesives, portend an exciting and promising future for dental adhesives. This review underscores the critical role of ongoing research in developing biocompatible, multifunctional, and durable adhesives. It aims to support dental professionals and researchers by providing a comprehensive understanding of the dynamic progression of dental adhesives, inspiring continued innovation and excellence in restorative dentistry. Full article
(This article belongs to the Special Issue Recent Advances in Dental Resin Composites)
Show Figures

Figure 1

16 pages, 1625 KiB  
Article
Long-Term Clinical Study on Sandblasted–Acid-Etched Surface Dental Implants: 12-Year Follow-Up
by Eugenio Velasco-Ortega, Jesús Pato-Mourelo, Borja López-López, Loreto Monsalve-Guil, Jesús Moreno-Muñoz, José López-López, Enrique Núñez-Márquez, Nuno Matos Garrido, José Luis Rondón-Romero, Álvaro Jiménez-Guerra and Iván Ortiz-García
Materials 2025, 18(1), 183; https://doi.org/10.3390/ma18010183 - 4 Jan 2025
Viewed by 1292
Abstract
Sandblasting and acid etching are common procedures used to treat implant surfaces, enhancing osseointegration and improving clinical success rates. This clinical study aimed to evaluate the long-term outcomes of sandblasted and acid-etched implants. A total of 303 implants were placed in 114 partially [...] Read more.
Sandblasting and acid etching are common procedures used to treat implant surfaces, enhancing osseointegration and improving clinical success rates. This clinical study aimed to evaluate the long-term outcomes of sandblasted and acid-etched implants. A total of 303 implants were placed in 114 partially and totally edentulous patients using a two-stage surgical technique and an early loading protocol (6–8 weeks). Clinical findings for implants and prosthetics were evaluated over a 12-year follow-up period. A total of 12 implants (3.9%) failed, with 3 failures occurring during the healing period before loading and 9 due to peri-implantitis. The cumulative survival rate for all implants was 96.1%. A total of 156 prostheses were placed on 300 implants, 87 single crowns, 45 partial fixed bridges, 9 full-arch fixed restorations, and 15 overdentures. The mean marginal bone loss was 1.18 mm. (SD. 0.64 mm.). Thirty-nine implants (13%) in twenty-four patients exhibited peri-implantitis. Technical complications, including prosthetic screw loosening or fracture, ceramic chipping, and acrylic fractures, were observed in 24 subjects (21.1%). Sandblasted and acid-etched surface implants placed in the maxilla and mandible reported favorable outcomes and stable tissue conditions with an early loading protocol. Full article
Show Figures

Figure 1

13 pages, 12855 KiB  
Case Report
Minimally Invasive Resin-Bonded Zirconia Veneers for the Treatment of Discolored Teeth: A Multidisciplinary Case Report by the First Committee of Junior Members of the Italian Dental Prosthesis and Oral Rehabilitation Society (SIPRO)
by Stefano Bertoni, Massimo Carossa, Riccardo Favero, Fabio Carboncini and Luigi Federico D’arienzo
Prosthesis 2025, 7(1), 1; https://doi.org/10.3390/prosthesis7010001 - 24 Dec 2024
Cited by 1 | Viewed by 1892
Abstract
Objectives: Among modern metal-free materials, zirconia, a high-performance ceramic material that can only be manufactured through CAM procedures, has certainly exponentially gained popularity thanks to its mechanical strength, biocompatibility, esthetic, and versatility. However, one of the main debates that has been raised in [...] Read more.
Objectives: Among modern metal-free materials, zirconia, a high-performance ceramic material that can only be manufactured through CAM procedures, has certainly exponentially gained popularity thanks to its mechanical strength, biocompatibility, esthetic, and versatility. However, one of the main debates that has been raised in relation to zirconia is its usage as an adhesive material. The present case report describes the clinical outcome of a multidisciplinary case finalized with adhesive minimally invasive zirconia veneers for the treatment of discolored teeth after a 24-month follow-up. Methods: A 19-year-old female patient with discolored upper frontal teeth (first premolar to first premolar) negatively affecting her self-esteem and social life was visited by a prosthodontic specialist. The treatment plan included orthodontic treatment, soft and hard tissue management through surgical procedures, and, lastly, minimally invasive adhesive zirconia veneers. The zirconia veneers bonding was performed under a rubber dam by conditioning the dental substrate by sandblasting the enamel with 40-micron aluminum oxide, etching with orthophosphoric acid 37%, and using a proper adhesive system. Monolithic zirconia restorations were sandblasted with 70-micron aluminum oxide at 0.2 MPa, then cleaned with a specific cleaner, and treated with a primer. Results: At the last follow-up (24 months), neither biological nor mechanical complications were observed. The patient anecdotally reported being very satisfied with the functional and esthetic results obtained. Therefore, the case was considered successful. Conclusions: Within the limitations of the present case report, the reported case on the use of minimally invasive resin-bonded zirconia veneers for the treatment of discolored teeth showed excellent outcomes after a 24-month follow-up. The use of zirconia as an adhesive material seems to be emerging. However, more clinical studies are required to validate the procedure. Full article
(This article belongs to the Special Issue Advancements in Zirconia Dental Restorations)
Show Figures

Figure 1

15 pages, 2257 KiB  
Article
Airborne-Particle Abrasion vs. Hydrofluoric Acid Etching of Dental Ceramics: Impact on the Tensile Bond Strength
by Valerie Lankes, Andrea Coldea, John Meinen, Falk Schwendicke and Bogna Stawarczyk
Materials 2024, 17(23), 5758; https://doi.org/10.3390/ma17235758 - 25 Nov 2024
Cited by 1 | Viewed by 1185
Abstract
This study evaluated whether airborne-particle abrasion could be an alternative to hydrofluoric acid etching as a pretreatment for the adhesive bonding of silicate ceramic restorations. Feldspar (FEL; n = 100), lithium silicate (LiSi; n = 100), and zirconia (ZrO2; (n = [...] Read more.
This study evaluated whether airborne-particle abrasion could be an alternative to hydrofluoric acid etching as a pretreatment for the adhesive bonding of silicate ceramic restorations. Feldspar (FEL; n = 100), lithium silicate (LiSi; n = 100), and zirconia (ZrO2; (n = 80) substrates were CAD/CAM-fabricated and airborne-particle-abraded with Al2O3 (25 µm or 50 µm of mean particle size) at pressures of 0.05 or 0.1 MPa. The controls included FEL (60 s) and LiSi (20 s) etched with hydrofluoric acid. The surface free energy (SFE) and roughness (Ra) were measured. For the tensile bond strength (TBS), surfaces were conditioned using a primer (Monobond Plus) and luted to a resin composite (Variolink Esthetic). TBS was assessed initially (24 h, 37 °C water storage) and after thermocycling (5/55 °C, 10,000×). Statistical analysis (SPSS, V29) was performed using a one-way ANOVA, post hoc Scheffé, and a two-group t-test (p = 0.05). Abrasion with 50 µm and 0.1 MPa induced the highest Ra values across the materials (62.5 ± 3.88 µm). ZrO2 exhibited a higher TBS (35.4–49.5 MPa) than FEL and LiSi. For aged LiSi, the specimens treated at 0.1 MPa showed a higher TBS (18.7 ± 9.0 MPa) than those treated at 0.05 MPa, regardless of the particle size. The etched and aged FEL showed a higher SFE but a lower TBS compared to abrasion. Al2O3 particle abrasion (25 or 50 µm at 0.1 MPa) may replace etching for silicate-based ceramics, while 50 µm is recommended for ZrO2 at either pressure. Full article
(This article belongs to the Special Issue Advanced Materials for Oral Applications)
Show Figures

Figure 1

12 pages, 3511 KiB  
Article
Enhancing Shear Bond Strength in Lithium Silicate Glass Ceramics: Surface Treatment Optimization for Reseating Protocols
by Allison Torbiak, Muna Bebsh, Asmaa Haimeur, Ana Carla Fernandes, Cristina Fiuza and Rodrigo França
Crystals 2024, 14(10), 856; https://doi.org/10.3390/cryst14100856 - 29 Sep 2024
Viewed by 1510
Abstract
The rapid evolution of lithium silicate-based glass ceramics in the field of dental ceramics has led to the availability of different compositions in the market. This in vitro study was conducted to assess an effective protocol for recementing de-bonded lithium silicate-based glass ceramics [...] Read more.
The rapid evolution of lithium silicate-based glass ceramics in the field of dental ceramics has led to the availability of different compositions in the market. This in vitro study was conducted to assess an effective protocol for recementing de-bonded lithium silicate-based glass ceramics by evaluating the shear bond strength of three reseating methods. The study included IPS e.max® CAD, Vita Suprinity®, Celtra Duo®, and n!ce as lithium-based glass ceramics. The samples underwent a series of preparation steps, including embedding in acrylic resin, hand polishing, etching with 5% hydrofluoric acid, and application of universal primer and adhesive as per manufacturer instructions. Subsequently, adhesive resin cement was applied to the ceramic tablets, and shear bond strength was assessed using a standardized method. The findings revealed that no single method demonstrated significantly superior results compared to the others. However, it was observed that etching with 5% hydrofluoric acid for 20 s yielded favorable outcomes in terms of time efficiency and standardized results. Additionally, it was noted that although sandblasting increased surface area, it did not enhance bond strength due to unfavorable surface disturbance. In conclusion, the study suggests that etching with 5% hydrofluoric acid for 20 s is a favorable protocol for reseating de-bonded lithium disilicate-based glass ceramics, offering both time efficiency and consistent results for clinicians. Full article
Show Figures

Figure 1

51 pages, 9758 KiB  
Review
A Literature Review of Adhesive Systems in Dentistry: Key Components and Their Clinical Applications
by Rim Bourgi, Naji Kharouf, Carlos Enrique Cuevas-Suárez, Monika Lukomska-Szymanska, Youssef Haikel and Louis Hardan
Appl. Sci. 2024, 14(18), 8111; https://doi.org/10.3390/app14188111 - 10 Sep 2024
Cited by 19 | Viewed by 19436
Abstract
The central aim of adhesive dentistry is to improve the compatibility between current adhesives and a range of substrates by employing diverse application techniques. Therefore, the overarching objective of this review is to offer a comprehensive analysis of dentin bonding systems, starting with [...] Read more.
The central aim of adhesive dentistry is to improve the compatibility between current adhesives and a range of substrates by employing diverse application techniques. Therefore, the overarching objective of this review is to offer a comprehensive analysis of dentin bonding systems, starting with an introduction to adhesion and a detailed overview of enamel and dentin structures, their histology, and the impact of dentin structure on resin–dentin bonding. It covers the mechanisms of resin–dentin bonding, including resin adhesive application, bonding mechanisms, and factors influencing efficacy. Further, this review explores the composition of resin adhesive systems, including acidic components, cross-linking monomers, solvents, and other critical elements. It also examines various adhesive strategies—etch-and-rinse, self-etch, and universal adhesives—highlighting their applications and advantages. The review extends to clinical applications of dental adhesion, including direct restorations, indirect restorations, and immediate dentin sealing (IDS), demonstrating the practical implications of adhesive systems in enhancing restoration longevity and performance. In conclusion, despite significant advancements, no gold-standard method for optimal adhesion exists. Each adhesive system has distinct strengths and limitations. The review emphasizes the importance of evaluating methods for achieving durable adhesion and staying current with technological advancements in adhesive systems. Summary: This review provides a thorough analysis of dentin bonding systems, delving into the structures and bonding mechanisms of both enamel and dentin. By exploring various adhesive systems and their components, it highlights the ongoing challenges in achieving optimal resin–dentin adhesion. The review also addresses the clinical applications of dental adhesion, including direct restorations, indirect restorations, and immediate dentin sealing (IDS), illustrating how different adhesive techniques impact clinical outcomes. It underscores the necessity for continuous innovation and assessment of adhesive systems to enhance long-term bonding effectiveness in clinical practice. Full article
(This article belongs to the Collection Dental Composites and Adhesives in Dentistry)
Show Figures

Figure 1

Back to TopTop