Sign in to use this feature.

Years

Between: -

Subjects

remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline

Journals

remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline

Article Types

Countries / Regions

remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline

Search Results (1,124)

Search Parameters:
Keywords = biomechanical tests

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
16 pages, 2388 KiB  
Article
Evaluating Lumbar Biomechanics for Work-Related Musculoskeletal Disorders at Varying Working Heights During Wall Construction Tasks
by Md. Sumon Rahman, Tatsuru Yazaki, Takanori Chihara and Jiro Sakamoto
Biomechanics 2025, 5(3), 58; https://doi.org/10.3390/biomechanics5030058 (registering DOI) - 3 Aug 2025
Abstract
Objectives: The aim of this study was to evaluate the impact of four working heights on lumbar biomechanics during wall construction tasks, focusing on work-related musculoskeletal disorders (WMSDs). Methods: Fifteen young male participants performed simulated mortar-spreading and bricklaying tasks while actual [...] Read more.
Objectives: The aim of this study was to evaluate the impact of four working heights on lumbar biomechanics during wall construction tasks, focusing on work-related musculoskeletal disorders (WMSDs). Methods: Fifteen young male participants performed simulated mortar-spreading and bricklaying tasks while actual body movements were recorded using Inertial Measurement Unit (IMU) sensors. Muscle activities of the lumbar erector spinae (ES), quadratus lumborum (QL), multifidus (MF), gluteus maximus (GM), and iliopsoas (IL) were estimated using a 3D musculoskeletal (MSK) model and measured via surface electromyography (sEMG). The analysis of variance (ANOVA) test was conducted to identify the significant differences in muscle activities across four working heights (i.e., foot, knee, waist, and shoulder). Results: Findings showed that working at foot-level height resulted in the highest muscle activity (7.6% to 40.6% increase), particularly in the ES and QL muscles, indicating an increased risk of WMSDs. The activities of the ES, MF, and GM muscles were statistically significant across both tasks and all working heights (p < 0.01). Conclusions: Both MSK and sEMG analyses indicated significantly lower muscle activities at knee and waist heights, suggesting these as the best working positions (47 cm to 107 cm) for minimizing the risk of WMSDs. Conversely, working at foot and shoulder heights was identified as a significant risk factor for WMSDs. Additionally, the similar trends observed between MSK simulations and sEMG data suggest that MSK modeling can effectively substitute for sEMG in future studies. These findings provide valuable insights into ergonomic work positioning to reduce WMSD risks among wall construction workers. Full article
(This article belongs to the Section Tissue and Vascular Biomechanics)
Show Figures

Figure 1

14 pages, 25742 KiB  
Article
Development and Simulation-Based Validation of Biodegradable 3D-Printed Cog Threads for Pelvic Organ Prolapse Repair
by Ana Telma Silva, Nuno Miguel Ferreira, Henrique Leon Bastos, Maria Francisca Vaz, Joana Pinheiro Martins, Fábio Pinheiro, António Augusto Fernandes and Elisabete Silva
Materials 2025, 18(15), 3638; https://doi.org/10.3390/ma18153638 (registering DOI) - 1 Aug 2025
Abstract
Pelvic organ prolapse (POP) is a prevalent condition, affecting women all over the world, and is commonly treated through surgical interventions that present limitations such as recurrence or complications associated with synthetic meshes. In this study, biodegradable poly(ϵ-caprolactone) (PCL) cog threads [...] Read more.
Pelvic organ prolapse (POP) is a prevalent condition, affecting women all over the world, and is commonly treated through surgical interventions that present limitations such as recurrence or complications associated with synthetic meshes. In this study, biodegradable poly(ϵ-caprolactone) (PCL) cog threads are proposed as a minimally invasive alternative for vaginal wall reinforcement. A custom cutting tool was developed to fabricate threads with varying barb angles (90°, 75°, 60°, and 45°), which were produced via Melt Electrowriting. Their mechanical behavior was assessed through uniaxial tensile tests and validated using finite element simulations. The results showed that barb orientation had minimal influence on tensile performance. In simulations of anterior vaginal wall deformation under cough pressure, all cog thread configurations significantly reduced displacement in the damaged tissue model, achieving values comparable to or even lower than those of healthy tissue. A ball burst simulation using an anatomically accurate model further demonstrated a 13% increase in reaction force with cog thread reinforcement. Despite fabrication limitations, this study supports the biomechanical potential of 3D-printed PCL cog threads for POP treatment, and lays the groundwork for future in vivo validation. Full article
24 pages, 5797 KiB  
Article
Topical Meglumine Antimoniate Gel for Cutaneous Leishmaniasis: Formulation, Evaluation, and In Silico Insights
by Lilian Sosa, Lupe Carolina Espinoza, Alba Pujol, José Correa-Basurto, David Méndez-Luna, Paulo Sarango-Granda, Diana Berenguer, Cristina Riera, Beatriz Clares-Naveros, Ana Cristina Calpena, Rafel Prohens and Marcelle Silva-Abreu
Gels 2025, 11(8), 601; https://doi.org/10.3390/gels11080601 (registering DOI) - 1 Aug 2025
Viewed by 55
Abstract
Leishmaniasis is an infectious disease common in tropical and subtropical regions worldwide. This study aimed to develop a topical meglumine antimoniate gel (MA-gel) for the treatment of cutaneous leishmaniasis. The MA-gel was characterized in terms of morphology, pH, swelling, porosity, rheology, and thermal [...] Read more.
Leishmaniasis is an infectious disease common in tropical and subtropical regions worldwide. This study aimed to develop a topical meglumine antimoniate gel (MA-gel) for the treatment of cutaneous leishmaniasis. The MA-gel was characterized in terms of morphology, pH, swelling, porosity, rheology, and thermal properties by differential scanning calorimetry (DSC). Biopharmaceutical evaluation included in vitro drug release and ex vivo skin permeation. Safety was evaluated through biomechanical skin property measurements and cytotoxicity in HaCaT and RAW 267 cells. Leishmanicidal activity was tested against promastigotes and amastigotes of Leishmania infantum, and in silico studies were conducted to explore possible mechanisms of action. The composition of the MA-gel included 30% MA, 20% Pluronic® F127 (P407), and 50% water. Scanning electron microscopy revealed a sponge-like and porous internal structure of the MA-gel. This formula exhibited a pH of 5.45, swelling at approximately 12 min, and a porosity of 85.07%. The DSC showed that there was no incompatibility between MA and P407. Drug release followed a first-order kinetic profile, with 22.11 µg/g/cm2 of the drug retained in the skin and no permeation into the receptor compartment. The MA-gel showed no microbial growth, no cytotoxicity in keratinocytes, and no skin damage. The IC50 for promastigotes and amastigotes of L. infantum were 3.56 and 23.11 µg/mL, respectively. In silico studies suggested that MA could act on three potential therapeutic targets according to its binding mode. The MA-gel demonstrated promising physicochemical, safety, and antiparasitic properties, supporting its potential as a topical treatment for cutaneous leishmaniasis. Full article
(This article belongs to the Special Issue Functional Hydrogels: Design, Processing and Biomedical Applications)
Show Figures

Figure 1

14 pages, 2149 KiB  
Article
Three-Dimensional-Printed Thermoplastic Polyurethane (TPU) Graft and H-Button Stabilization System for Intra-Articular Cranial Cruciate Ligament Reconstruction: Cadaveric Study
by Menna Nahla, Yara Abouelela, Mohammed Amer, Marwa Ali, Abdelbary Prince, Ayman Tolba and Ayman Mostafa
Vet. Sci. 2025, 12(8), 725; https://doi.org/10.3390/vetsci12080725 (registering DOI) - 31 Jul 2025
Viewed by 67
Abstract
Cranial cruciate ligament (CrCL) rupture is a common orthopedic disorder in dogs, leading to stifle joint instability and progressive osteoarthritis. This study aimed to develop and biomechanically evaluate a novel intra-articular reconstruction system designed to mimic the natural ligament and restore joint stability [...] Read more.
Cranial cruciate ligament (CrCL) rupture is a common orthopedic disorder in dogs, leading to stifle joint instability and progressive osteoarthritis. This study aimed to develop and biomechanically evaluate a novel intra-articular reconstruction system designed to mimic the natural ligament and restore joint stability following CrCL excision. The system consisted of a 3D-printed thermoplastic polyurethane (TPU) graft, cerclage wire, and H-button fixation. Fourteen pelvic limbs from mature mixed-breed cadaveric dogs were used. The inclination angle, dimensions, volume, tensile strength, and elongation of the native CrCL were measured. Seven CrCL-deficient stifles were reconstructed using the proposed system and tested biomechanically. The native CrCL showed a significantly higher tensile strength than the TPU graft; however, the TPU demonstrated a greater flexibility. The reconstruction system successfully stabilized the joint and provided repeatable fixation. Significant correlations were found between CrCL volume and both age and body weight. These findings support the mechanical suitability of the proposed system for ex vivo stifle stabilization and highlight the potential of 3D-printed TPU in ligament reconstruction. Further in vivo studies are recommended to assess long-term performance, including implant integration, tissue remodeling, and clinical outcomes. Full article
(This article belongs to the Section Veterinary Surgery)
Show Figures

Figure 1

16 pages, 1667 KiB  
Article
Quantification of the Effect of Saddle Fitting on Rider–Horse Biomechanics Using Inertial Measurement Units
by Blandine Becard, Marie Sapone, Pauline Martin, Sandrine Hanne-Poujade, Alexa Babu, Camille Hébert, Philippe Joly, William Bertucci and Nicolas Houel
Sensors 2025, 25(15), 4712; https://doi.org/10.3390/s25154712 - 30 Jul 2025
Viewed by 279
Abstract
The saddle’s adaptability to the rider–horse pair’s biomechanics is essential for equestrian comfort and performance. However, approaches to dynamic evaluation of saddle fitting are still limited in equestrian conditions. The purpose of this study is to propose a method of quantifying saddle adaptation [...] Read more.
The saddle’s adaptability to the rider–horse pair’s biomechanics is essential for equestrian comfort and performance. However, approaches to dynamic evaluation of saddle fitting are still limited in equestrian conditions. The purpose of this study is to propose a method of quantifying saddle adaptation to the rider–horse pair in motion. Eight rider–horse pairs were tested using four similar saddles with small modifications (seat depth, flap width, and front panel thickness). Seven inertial sensors were attached to the riders and horses to measure the active range of motion of the horses’ forelimbs and hindlimbs, stride duration, active range of motion of the rider’s pelvis, and rider–horse interaction. The results reveal that even small saddle changes affect the pair’s biomechanics. Some saddle configurations limit the limbs’ active range of motion, lengthen strides, or modify the rider’s pelvic motion. The temporal offset between the movements of the horse and the rider changes depending on the saddle modifications. These findings support the effect of fine saddle changes on the locomotion and synchronization of the rider–horse pair. The use of inertial sensors can be a potential way for quantifying the influence of dynamic saddle fitting and optimizing saddle adaptability in stable conditions with saddle fitter constraints. Full article
Show Figures

Graphical abstract

14 pages, 827 KiB  
Article
Sensor Fusion for Enhancing Motion Capture: Integrating Optical and Inertial Motion Capture Systems
by Hailey N. Hicks, Howard Chen and Sara A. Harper
Sensors 2025, 25(15), 4680; https://doi.org/10.3390/s25154680 - 29 Jul 2025
Viewed by 296
Abstract
This study aimed to create and evaluate an optimization-based sensor fusion algorithm that combines Optical Motion Capture (OMC) and Inertial Motion Capture (IMC) measurements to provide a more efficient and reliable gap-filling process for OMC measurements to be used for future research. The [...] Read more.
This study aimed to create and evaluate an optimization-based sensor fusion algorithm that combines Optical Motion Capture (OMC) and Inertial Motion Capture (IMC) measurements to provide a more efficient and reliable gap-filling process for OMC measurements to be used for future research. The proposed algorithm takes the first and last frame of OMC data and fills the rest with gyroscope data from the IMC. The algorithm was validated using data from twelve participants who performed a hand cycling task with an inertial measurement unit (IMU) placed on their hand, forearm, and upper arm. The OMC tracked a cluster of reflective markers that were placed on top of each IMU. The proposed algorithm was evaluated with simulated gaps of up to five minutes. Average total root-mean-square errors (RMSE) of <1.8° across a 5 min duration were observed for all sensor placements for the cyclic upper limb motion pattern used in this study. The results demonstrated that the fusion of these two sensing modalities is feasible and shines light on the possibility of more field-based studies for human motion analysis. Full article
Show Figures

Figure 1

16 pages, 2280 KiB  
Article
Mechanical Properties of Korla Fragrant Pear Fruiting Branches and Pedicels: Implications for Non-Destructive Harvesting
by Yanwu Jiang, Jun Chen, Zhiwei Wang, Jianguo Zhou and Guangrui Hu
Horticulturae 2025, 11(8), 880; https://doi.org/10.3390/horticulturae11080880 - 29 Jul 2025
Viewed by 217
Abstract
The Korla fragrant pear is a highly valued economic fruit in China’s Xinjiang region. However, biomechanical data on the fruit-bearing branches and pedicels of this species remain incomplete, which to some extent hinders the advancement of harvesting equipment and techniques. Therefore, refining these [...] Read more.
The Korla fragrant pear is a highly valued economic fruit in China’s Xinjiang region. However, biomechanical data on the fruit-bearing branches and pedicels of this species remain incomplete, which to some extent hinders the advancement of harvesting equipment and techniques. Therefore, refining these data is of great significance for the development of efficient and non-destructive harvesting strategies. This study aims to elucidate the mechanical properties of the fruiting branches and peduncles of Korla fragrant pears, thereby establishing a theoretical foundation for the future development of intelligent harvesting technology for this variety. The research utilized axial and radial compression tests, along with three-point bending test methods, to quantitatively analyze the elastic modulus and shear modulus of the branches and peduncles. The test results reveal that the elastic modulus of the fruiting branches under axial compression is 263.51 ± 76.51 MPa, while under radial compression, it measures 135.53 ± 73.73 MPa (where ± represents the standard deviation). In comparison, the elastic modulus of the peduncles is recorded at 152.96 ± 119.95 MPa. Additionally, the three-point bending test yielded a shear modulus of 75.48 ± 32.84 MPa for the branches and 30.23 ± 8.50 MPa for the peduncles. Using finite element static structural analysis, the simulation results aligned closely with the experimental data, falling within an acceptable error range, thus validating the reliability of the testing methods and outcomes. The mechanical parameters obtained in this study are critical for modeling the stress and deformation behaviors of pear-bearing structures during mechanical harvesting. These findings provide valuable theoretical support for the optimization of harvesting device design and operational strategies, with the aim of reducing fruit damage and improving harvesting efficiency in pear orchards. Full article
(This article belongs to the Section Postharvest Biology, Quality, Safety, and Technology)
Show Figures

Figure 1

12 pages, 732 KiB  
Article
Umbilical Cord Tensile Strength Under Varying Strain Rates
by Maria Antonietta Castaldi, Pietro Villa, Alfredo Castaldi and Salvatore Giovanni Castaldi
Bioengineering 2025, 12(8), 789; https://doi.org/10.3390/bioengineering12080789 - 22 Jul 2025
Viewed by 231
Abstract
The tensile strength of the umbilical cord (UC) is influenced by its composition—including collagen, elastin, and hyaluronan—contributing to its unique biomechanical properties. This experimental in vitro study aimed to evaluate the UC’s mechanical behavior under varying strain rates and to characterize its viscoelastic [...] Read more.
The tensile strength of the umbilical cord (UC) is influenced by its composition—including collagen, elastin, and hyaluronan—contributing to its unique biomechanical properties. This experimental in vitro study aimed to evaluate the UC’s mechanical behavior under varying strain rates and to characterize its viscoelastic response. Twenty-nine UC specimens, each 40 mm in length, were subjected to uniaxial tensile testing and randomly assigned to three traction speed groups: Group A (n = 10) at 8 mm/min, Group B (n = 7) at 12 mm/min, and Group C (n = 12) at 16 mm/min. Four different parameters were analyzed: the ultimate tensile strength and its corresponding elongation, the elastic modulus defined as the slope of the linear initial portion of the stress–strain plot, and the elongation at the end of the test (at break). While elongation and elongation at break did not differ significantly between groups (one-way ANOVA), Group C showed a significantly higher ultimate tensile strength (p = 0.047). A linear relationship was observed between test speed and stiffness (elastic modulus), with the following regression equation: y = 0.3078e4.425x. These findings confirm that the UC exhibits nonlinear viscoelastic properties and strain-rate-dependent stiffening, resembling non-Newtonian behavior. This novel insight may have clinical relevance during operative deliveries, where traction speed is often overlooked but may play a role in preserving cord integrity and improving neonatal outcomes. Full article
(This article belongs to the Section Biosignal Processing)
Show Figures

Figure 1

15 pages, 802 KiB  
Article
Differential Cortical Activations Among Young Adults Who Fall Versus Those Who Recover Successfully Following an Unexpected Slip During Walking
by Rudri Purohit, Shuaijie Wang and Tanvi Bhatt
Brain Sci. 2025, 15(7), 765; https://doi.org/10.3390/brainsci15070765 - 18 Jul 2025
Viewed by 279
Abstract
Background: Biomechanical and neuromuscular differences between falls and recoveries have been well-studied; however, the cortical correlations remain unclear. Using mobile brain imaging via electroencephalography (EEG), we examined differences in sensorimotor beta frequencies between falls and recoveries during an unpredicted slip in walking. Methods [...] Read more.
Background: Biomechanical and neuromuscular differences between falls and recoveries have been well-studied; however, the cortical correlations remain unclear. Using mobile brain imaging via electroencephalography (EEG), we examined differences in sensorimotor beta frequencies between falls and recoveries during an unpredicted slip in walking. Methods: We recruited 22 young adults (15 female; 18–35 years) who experienced a slip (65 cm) during walking. Raw EEG signals were band-pass filtered, and independent component analysis was performed to remove non-neural sources, eventually three participants were excluded due to excessive artifacts. Peak beta power was extracted from three time-bins: 400 milliseconds pre-, 0–150 milliseconds post and 150–300 milliseconds post-perturbation from the midline (Cz) electrode. A 2 × 3 Analysis of Covariance assessed the interaction between time-bins and group on beta power, followed by Independent and Paired t-tests for between and within-group post hoc comparisons. Results: All participants (n = 19) experienced a balance loss, seven experienced a fall. There was a time × group interaction on beta power (p < 0.05). With no group differences pre-perturbation, participants who experienced a fall exhibited higher beta power during 0–150 milliseconds post-perturbation than those who recovered (p < 0.001). However, there were no group differences in beta power during 150–300 milliseconds post-perturbation. Conclusions: Young adults exhibiting a greater increase in beta power during the early post-perturbation period experienced a fall, suggesting a higher cortical error detection due to a larger mismatch in the expected and ongoing postural state and greater cortical dependence for sensorimotor processing. Our study results provide an overview of the possible cortical governance to modulate slip-fall/recovery outcomes. Full article
(This article belongs to the Section Behavioral Neuroscience)
Show Figures

Figure 1

10 pages, 997 KiB  
Article
Does Malpositioning of Pedicle Screws Affect Biomechanical Stability in a Novel Quasistatic Test Setup?
by Stefan Schleifenbaum, Florian Metzner, Janine Schultze, Sascha Kurz, Christoph-Eckhard Heyde and Philipp Pieroh
Bioengineering 2025, 12(7), 781; https://doi.org/10.3390/bioengineering12070781 - 18 Jul 2025
Viewed by 373
Abstract
Pedicle screw fixation is a common spinal surgery technique, but concerns remain about stability when screws are malpositioned. Traditional in vitro pull-out tests assess anchorage but lack physiological accuracy. This study examined the stability of correctly placed and intentionally malpositioned pedicle screws on [...] Read more.
Pedicle screw fixation is a common spinal surgery technique, but concerns remain about stability when screws are malpositioned. Traditional in vitro pull-out tests assess anchorage but lack physiological accuracy. This study examined the stability of correctly placed and intentionally malpositioned pedicle screws on forty vertebrae from five cadavers. Optimal screw paths were planned via CT scans and applied using 3D-printed guides. Four malposition types—medial, lateral, superior, and superior-lateral—were created by shifting the original trajectory. A custom setup applied three consecutive cycles of tensile and compressive load from 50 N to 200 N. Screw inclination under load was measured with a 3D optical system. The results showed increasing screw inclination with higher forces, reaching about 1° at 50 N and 2° at 100 N, similar in both load directions. Significant differences in inclination were only found at 100 N tensile load, where malpositioned screws showed a lower inclination. Overall, malpositioning had no major effect on screw loosening. These findings suggest that minor deviations in screw placement do not significantly compromise mechanical stability. Clinically, the main concern with malpositioning lies in the potential for injury to nearby structures rather than reduced screw fixation strength. Full article
(This article belongs to the Special Issue Spine Biomechanics)
Show Figures

Figure 1

14 pages, 1084 KiB  
Article
Dynamic Changes in Mimic Muscle Tone During Early Orthodontic Treatment: An sEMG Study
by Oskar Komisarek, Roksana Malak and Paweł Burduk
J. Clin. Med. 2025, 14(14), 5048; https://doi.org/10.3390/jcm14145048 - 16 Jul 2025
Viewed by 262
Abstract
Background: Surface electromyography (sEMG) enables the non-invasive assessment of muscle activity and is widely used in orthodontics for evaluating masticatory muscles. However, little is known about the dynamic changes in facial expression muscles during orthodontic treatment. This study aimed to investigate alterations in [...] Read more.
Background: Surface electromyography (sEMG) enables the non-invasive assessment of muscle activity and is widely used in orthodontics for evaluating masticatory muscles. However, little is known about the dynamic changes in facial expression muscles during orthodontic treatment. This study aimed to investigate alterations in facial muscle tone during the leveling and alignment phase in adult female patients undergoing fixed appliance therapy. Methods: The study included 30 female patients aged 20–31 years who underwent sEMG assessment at four time points: before treatment initiation (T0), at the start of appliance placement (T1), three months into treatment (T2), and six months into treatment (T3). Muscle activity was recorded during four standardized facial expressions: eye closure, nasal strain, broad smile, and lip protrusion. Electrodes were placed on the orbicularis oris, orbicularis oculi, zygomaticus major, and levator labii superioris alaeque nasi muscles. A total of 1440 measurements were analyzed using Friedman and Conover-Inman tests (α = 0.05). Results: Significant changes in muscle tone were observed during treatment. During lip protrusion, the orbicularis oris and zygomaticus major showed significant increases in peak and minimum activity (p < 0.01). Eye closure was associated with altered orbicularis oris activation bilaterally at T3 (p < 0.01). Nasal strain induced significant changes in zygomaticus and levator labii muscle tone, particularly on the right side (p < 0.05). No significant changes were noted during broad smiling. Conclusions: Orthodontic leveling and alignment influence the activity of selected facial expression muscles, demonstrating a dynamic neuromuscular adaptation during treatment. These findings highlight the importance of considering soft tissue responses in orthodontic biomechanics and suggest potential implications for facial esthetics and muscle function monitoring. Full article
(This article belongs to the Section Dentistry, Oral Surgery and Oral Medicine)
Show Figures

Figure 1

21 pages, 899 KiB  
Article
Cervical Spine Range of Motion Reliability with Two Methods and Associations with Demographics, Forward Head Posture, and Respiratory Mechanics in Patients with Non-Specific Chronic Neck Pain
by Petros I. Tatsios, Eirini Grammatopoulou, Zacharias Dimitriadis, Irini Patsaki, George Gioftsos and George A. Koumantakis
J. Funct. Morphol. Kinesiol. 2025, 10(3), 269; https://doi.org/10.3390/jfmk10030269 - 16 Jul 2025
Cited by 1 | Viewed by 359
Abstract
Objectives: New smartphone-based methods for measuring cervical spine range of motion (CS-ROM) and posture are emerging. The purpose of this study was to assess the reliability and validity of three such methods in patients with non-specific chronic neck pain (NSCNP). Methods: [...] Read more.
Objectives: New smartphone-based methods for measuring cervical spine range of motion (CS-ROM) and posture are emerging. The purpose of this study was to assess the reliability and validity of three such methods in patients with non-specific chronic neck pain (NSCNP). Methods: The within-day test–retest reliability of CS-ROM and forward head posture (craniovertebral angle-CVA) was examined in 45 patients with NSCNP. CS-ROM was simultaneously measured with an accelerometer sensor (KFORCE Sens®) and a mobile phone device (iHandy and Compass apps), testing the accuracy of each and the parallel-forms reliability between the two methods. For construct validity, correlations of CS-ROM with demographics, lifestyle, and other cervical and thoracic spine biomechanically based measures were examined in 90 patients with NSCNP. Male–female differences were also explored. Results: Both methods were reliable, with measurements concurring between the two devices in all six movement directions (intraclass correlation coefficient/ICC = 0.90–0.99, standard error of the measurement/SEM = 0.54–3.09°). Male–female differences were only noted for two CS-ROM measures and CVA. Significant associations were documented: (a) between the six CS-ROM measures (R = 0.22–0.54, p < 0.05), (b) participants’ age with five out of six CS-ROM measures (R = 0.23–0.40, p < 0.05) and CVA (R = 0.21, p < 0.05), (c) CVA with two out of six CS-ROM measures (extension R = 0.29, p = 0.005 and left-side flexion R = 0.21, p < 0.05), body mass (R = −0.39, p < 0.001), body mass index (R = −0.52, p < 0.001), and chest wall expansion (R = 0.24–0.29, p < 0.05). Significantly lower forward head posture was noted in subjects with a high level of physical activity relative to those with a low level of physical activity. Conclusions: The reliability of both CS-ROM methods was excellent. Reductions in CS-ROM and increases in CVA were age-dependent in NSCNP. The significant relationship identified between CVA and CWE possibly signifies interconnections between NSCNP and the biomechanical aspect of dysfunctional breathing. Full article
(This article belongs to the Section Kinesiology and Biomechanics)
Show Figures

Figure 1

37 pages, 18532 KiB  
Article
Regeneration of Biomechanically Functional Tendon Tissue Following Injection of Uncultured, Autologous, Adipose-Derived Regenerative Cells into Partial Achilles Tendon Defects in Rabbits
by Christoph Schmitz, Christopher Alt, Tobias Wuerfel, Stefan Milz, Jacqueline Dinzey, Ashley Hill, Katie J. Sikes, Lindsey H. Burton, Jeremiah Easley, Holly L. Stewart, Christian M. Puttlitz, Benjamin C. Gadomski, Kevin M. Labus, David A. Pearce, Nicola Maffulli and Eckhard U. Alt
Int. J. Mol. Sci. 2025, 26(14), 6800; https://doi.org/10.3390/ijms26146800 - 16 Jul 2025
Viewed by 506
Abstract
Current treatment strategies for partial tendon tears often lack the capacity to promote true tissue regeneration and improve long-term clinical outcomes. This study tested the hypothesis that treatment of a partial defect in the rabbit common calcaneus tendon (CCT) with uncultured, unmodified, autologous, [...] Read more.
Current treatment strategies for partial tendon tears often lack the capacity to promote true tissue regeneration and improve long-term clinical outcomes. This study tested the hypothesis that treatment of a partial defect in the rabbit common calcaneus tendon (CCT) with uncultured, unmodified, autologous, adipose-derived regenerative cells (UA-ADRCs) enables regenerative healing without scar formation. A full-thickness, 3 mm defect was produced in the midsubstance of the right gastrocnemius tendon, a component of the CCT, in adult female New Zealand white rabbits. Animals received either an injection of 28.3 × 106 UA-ADRCs in 0.5 mL Ringer’s lactated solution (RLS) or saline, or RLS or saline alone as sham treatment. Tendons were analyzed 4 or 12 weeks post-treatment using histology, immunohistochemistry and non-destructive biomechanical testing. UA-ADRC-treated tendons showed newly formed connective tissue consistent with tendon regeneration, whereas sham-treated tendons developed scar tissue. Biomechanical testing showed significantly higher percent relaxation in UA-ADRC-treated tendons compared to sham controls (p < 0.05), indicating greater viscoelasticity characteristic of healthy or well-integrated tissue. Together, these findings suggest that UA-ADRC therapy may provide a regenerative, structure-modifying treatment for partial tendon tears. Full article
(This article belongs to the Section Molecular Pathology, Diagnostics, and Therapeutics)
Show Figures

Figure 1

14 pages, 2241 KiB  
Article
Cross-Sectional Study of Occlusal Loading and Periodontal Status of Teeth with Deflective Occlusal Contacts
by Ximena Anca Nicolae, Elena Preoteasa, Catalina Murariu Magureanu and Cristina Teodora Preoteasa
Bioengineering 2025, 12(7), 766; https://doi.org/10.3390/bioengineering12070766 - 16 Jul 2025
Viewed by 391
Abstract
Aim: To evaluate whether maximum occlusal loading and periodontal status are different between teeth presenting deflective occlusal contacts and those without such contacts, specifically adjacent and homologous teeth. Method: A cross-sectional study was conducted using OccluSense to detect deflective contacts and quantify occlusal [...] Read more.
Aim: To evaluate whether maximum occlusal loading and periodontal status are different between teeth presenting deflective occlusal contacts and those without such contacts, specifically adjacent and homologous teeth. Method: A cross-sectional study was conducted using OccluSense to detect deflective contacts and quantify occlusal load per tooth. For group comparisons, the Kruskal–Wallis, Friedman, Cochran’s Q, and chi-squared tests were used. Results: A total of 493 teeth with deflective contacts were compared to 473 adjacent (first control group) and 457 homologous teeth (second control group). Teeth with deflective contacts showed significantly higher occlusal loading (mean value: 208) than adjacent (72) and homologous teeth (97) (p < 0.05). They also exhibited more advanced periodontal damage, including deeper probing depths, greater gingival recession, alveolar bone loss, and a wider periodontal ligament space. Deflective contacts in centric relation were more strongly linked to periodontal deterioration than those in protrusive or lateral mandibular movements, despite similar occlusal forces. Conclusions: Within this study’s limitations, deflective occlusal contacts are associated with increased occlusal forces and more severe periodontal damage, suggesting a biomechanical factor in periodontal disease progression. Full article
Show Figures

Figure 1

19 pages, 2559 KiB  
Article
Development of Patient-Specific Lattice Structured Femoral Stems Based on Finite Element Analysis and Machine Learning
by Rashwan Alkentar, Sándor Manó, Dávid Huri and Tamás Mankovits
Crystals 2025, 15(7), 650; https://doi.org/10.3390/cryst15070650 - 15 Jul 2025
Viewed by 338
Abstract
Hip implant optimization is increasingly receiving attention due to the development of manufacturing technology and artificial intelligence interaction in the current research. This study investigates the development of hip implant stem design with the application of lattice structures, and the utilization of the [...] Read more.
Hip implant optimization is increasingly receiving attention due to the development of manufacturing technology and artificial intelligence interaction in the current research. This study investigates the development of hip implant stem design with the application of lattice structures, and the utilization of the MATLAB regression learner app in finding the best predictive regression model to calculate the mechanical behavior of the implant’s stem based on some of the design parameters. Many cases of latticed hip implants (using 3D lattice infill type) were designed in the ANSYS software, and then 3D printed to undergo simulations and lab experiments. A surrogate model of the implant was used in the finite element analysis (FEA) instead of the geometrically latticed model to save computation time. The model was then generalized and used to calculate the mechanical behavior of new variables of hip implant stem and a database was generated for surgeon so they can choose the lattice parameters for desirable mechanical behavior. This study shows that neural networks algorithms showed the highest accuracy with predicting the mechanical behavior reaching a percentage above 90%. Patients’ weight and shell thickness were proven to be the most affecting factors on the implant’s mechanical behavior. Full article
(This article belongs to the Special Issue Celebrating the 10th Anniversary of International Crystallography)
Show Figures

Figure 1

Back to TopTop