Sign in to use this feature.

Years

Between: -

Subjects

remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline

Journals

Article Types

Countries / Regions

Search Results (45)

Search Parameters:
Keywords = annular array

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
18 pages, 7342 KB  
Article
Simulation and Experimental Investigation of Secondary Electron Emission Regulation on Ferrite Medium Using Raised Microstructures
by Yali Niu, Yun Li, Guobao Feng and Qian Yuan
Coatings 2026, 16(7), 802; https://doi.org/10.3390/coatings16070802 - 6 Jul 2026
Viewed by 379
Abstract
Ferrite is an essential functional material for high-power nonreciprocal microwave components, such as circulators and isolators, and its secondary electron emission (SEE) property is critical for suppressing the multipactor effect under vacuum conditions. In this work, we propose a surface engineering strategy based [...] Read more.
Ferrite is an essential functional material for high-power nonreciprocal microwave components, such as circulators and isolators, and its secondary electron emission (SEE) property is critical for suppressing the multipactor effect under vacuum conditions. In this work, we propose a surface engineering strategy based on periodic raised microstructures to regulate the secondary electron yield (SEY) of ferrite coatings/substrates. A Monte Carlo-based numerical method is developed to calculate the SEY of ferrite with hexagonal and annular microprotrusions of varying heights and geometric parameters. The dependence of SEY on microstructure dimensions is systematically analyzed. Spinel ferrite samples with designed microstructures are fabricated via mechanical processing. For hexagonal column arrays with a height of 1.5 mm, a side length of 0.5 mm, and a pitch of 1.67 mm, the maximum SEY is reduced from 2.4 (smooth surface) to 1.7 while the annular concentric protrusion arrays decrease the maximum SEY to 2.1. Effective suppression is achieved over the entire incident energy range for both microstructural designs. Despite a lower reduction, the annular arrays offer geometrically isotropic electron trapping, which may be advantageous for devices with circular or coaxial cavity geometries where directional dependence of the surface texture is undesirable. The results demonstrate that tailored surface microstructures can significantly mitigate SEE of ferrite, providing a promising route for developing high-performance ferrite coatings toward multipactor suppression in space microwave devices. Full article
(This article belongs to the Section Ceramic Coatings and Engineering Technology)
Show Figures

Figure 1

16 pages, 2815 KB  
Article
A Longitudinal Layer-Wise Strategy for Fabricating Tapered Micro-Cones by Ion-Beam Etching
by Jingyu Huang, Chenhui Deng, Pengfei Wang, Bohua Yin, Liping Zhang and Li Han
Electronics 2026, 15(10), 2193; https://doi.org/10.3390/electronics15102193 - 19 May 2026
Viewed by 302
Abstract
The controllable fabrication of tapered three-dimensional (3D) microstructures by ion-beam processing remains challenging, especially when both profile fidelity and geometric controllability are required. Tapered conical microstructures are of interest because they are relevant to a variety of applications, including micro-optical elements, functional textured [...] Read more.
The controllable fabrication of tapered three-dimensional (3D) microstructures by ion-beam processing remains challenging, especially when both profile fidelity and geometric controllability are required. Tapered conical microstructures are of interest because they are relevant to a variety of applications, including micro-optical elements, functional textured surfaces, biomimetic interfaces, and field-enhancing emitter-related structures, where taper angle, aspect ratio, and structural uniformity strongly influence the resulting performance. In this work, a longitudinal layer-wise strategy is proposed for tapered micro-cone fabrication by ion-beam etching. The core idea is to discretize a continuous cone profile along the vertical direction into a sequence of annular layers whose dimensions are determined by the local geometry of the target three-dimensional structure. After this geometric discretization step, each individual layer is executed using a conventional multi-pass strategy, thereby combining longitudinal profile construction with stabilized local material removal. A dedicated pattern-design software, EBWriter, was developed to automatically generate annular patterns and process files from user-defined geometric parameters. Experimental validation was carried out on single-crystal silicon substrates using a dual-beam microscope platform operated at 30 kV. The results show that increasing the longitudinal layer number effectively weakens the staircase effect and improves the continuity of the reconstructed cone profile. For positive micro-cones fabricated using annular patterns with a nominal outer processing diameter of 3 μm, the increasing-inner-radius strategy enables preservation of the cone apex and reconstruction of tapered morphologies with improved fidelity. Under the present processing conditions, an empirical correspondence between the target geometric ratio and the recommended layer number was further summarized: layer numbers of approximately 50, 100, and 300 support cone structures with base-diameter-to-height ratios close to 1:2, 1:3, and 1:4, respectively. In addition, a 3 × 3 positive micro-cone array was successfully fabricated, with a total processing time of about 80 s. The measured cone base diameter and height were 0.886 ± 0.005 μm and 2.354 ± 0.023 μm, respectively, with dimensional variations controlled within ±2%. These results demonstrate that the proposed method provides a feasible layer-wise ion-beam fabrication route for tapered microstructures and offers a useful process basis for future studies on micro-optical surfaces, functional textured interfaces, and emitter-related microstructures. Full article
Show Figures

Figure 1

22 pages, 8460 KB  
Article
Design and Implementation of a Three-Segment Tendon-Driven Continuum Robot with Variable Stiffness for Manipulation in Confined Spaces
by Zhixuan Weng, Liansen Sha, Yufei Chen, Bingyu Fan, Lan Li and Bin Liu
Biomimetics 2026, 11(2), 113; https://doi.org/10.3390/biomimetics11020113 - 4 Feb 2026
Viewed by 2005
Abstract
Continuum robots (CRs) exhibit high compliance and environmental adaptability in confined, tortuous spaces, yet their inherent low stiffness and load capacity limit performance in precise positioning and stable support tasks. To solve the “soft-rigid” paradox, this study proposes and implements a three-segment tendon-driven [...] Read more.
Continuum robots (CRs) exhibit high compliance and environmental adaptability in confined, tortuous spaces, yet their inherent low stiffness and load capacity limit performance in precise positioning and stable support tasks. To solve the “soft-rigid” paradox, this study proposes and implements a three-segment tendon-driven variable-stiffness CR. Structurally, a segmented constant-curvature model directs the optimization of grid skeletons and notch parameters, enhancing bending consistency and motion predictability. Elongated flat airbag actuators, arranged in annular arrays, enable segment-level stiffness switching through the enhancement of surface properties like axial constraints and friction amplification. A time-sharing drive strategy decouples multi-segment coupling into sequential single-segment subproblems, reducing drivers and kinematic complexity while maintaining dexterity. Experimental results demonstrate that flexible-mode joints maintain near-constant curvature with stable motion (average end-effector trajectory error < 0.9 mm), and in rigid mode, stiffness increases by a factor of 5.77 (rated load: 4.0 N). Shape-locking disturbances during transitions are confined to millimeter levels (remote offset < 1.32 mm), with successful traversal of J/U/S-shaped and irregular paths confirmed in pipeline tests. This work introduces a practical, scalable system for designing variable-stiffness structures and enabling low-complexity multi-segment control, offering valuable insights for minimally invasive devices and industrial endoscopy in confined spaces. Full article
Show Figures

Graphical abstract

16 pages, 6330 KB  
Article
Convergent Annular Thermoelectric Generator with Fish-Fin-like Heat Exchange
by Ning Wang, Zirui Zhang, Jiahao Li, Jianxiang Cheng, Hongzhi Jia, Bo Dai and Dawei Zhang
Energies 2026, 19(3), 762; https://doi.org/10.3390/en19030762 - 1 Feb 2026
Viewed by 581
Abstract
To address the critical challenge of low thermoelectric conversion efficiency in high-temperature, highly turbulent waste heat recovery, a novel fish-fin convergent annular thermoelectric generator (FF-CATEG) device is proposed. An annular contraction-type thermal conduction ceramic component is designed along the axial gradient direction, with [...] Read more.
To address the critical challenge of low thermoelectric conversion efficiency in high-temperature, highly turbulent waste heat recovery, a novel fish-fin convergent annular thermoelectric generator (FF-CATEG) device is proposed. An annular contraction-type thermal conduction ceramic component is designed along the axial gradient direction, with fish-fin-like fins and thermocouple annular arrays introduced on the inner and outer walls of the ceramic, respectively. Therefore, the directional transport through the cross-coupling of fluid kinetic energy and thermal energy is achieved, significantly improving the thermoelectric conversion efficiency of the proposed structure. Experimental validation demonstrates that the optimized FF-CATEG attains a maximum net output power of 6.17 W at a pipe contraction angle of 3.5° and a fin coverage of 13.44%. With a temperature difference of 320 K and a waste heat fluid velocity of 14.5 m/s, the thermoelectric conversion efficiency is enhanced to 3.97%, representing a substantial 39.3% improvement compared to the finless configuration. This study presents a new approach for recovering waste heat from turbulent flows. Full article
(This article belongs to the Section J: Thermal Management)
Show Figures

Figure 1

20 pages, 7589 KB  
Article
Practical Method for Evaluating the Element Sensitivity Variation of an Ultrasonic Annular Phased Array Transducer
by Zhengxiao Sha, Xiao Liu, Yanze Liu, Xiao Wang and Xiaoming Zhou
Sensors 2026, 26(1), 25; https://doi.org/10.3390/s26010025 - 19 Dec 2025
Viewed by 1361
Abstract
The unique features of annular phased array transducers, such as ring-shaped elements and the concentric configuration, cause them to behave differently from commonly used linear array transducers, in terms of sound field distribution and pulse–echo response. Consequently, standard techniques for assessing linear array [...] Read more.
The unique features of annular phased array transducers, such as ring-shaped elements and the concentric configuration, cause them to behave differently from commonly used linear array transducers, in terms of sound field distribution and pulse–echo response. Consequently, standard techniques for assessing linear array transducers can introduce significant errors when applied to annular array transducers, especially concerning element-to-element sensitivity variance. This study investigates the consistency of element sensitivity in annular phased array transducers. Through theoretical analysis, a Long-Belt source assumption model was developed based on the Rayleigh integral to characterize the responses of ring-shaped elements in an analytical and explicit form. The model suggests that the response amplitude is linearly correlated with the radial width of the element, which was validated by subsequent numerical simulations. Based on these findings, a modified sensitivity evaluation algorithm for annular array transducers is presented. The response voltage per unit width, rather than the total response voltage, is used to eliminate the influence of varying geometries and sizes across elements. The sensitivity variation of a 32-element annular array transducer was evaluated using the new algorithm. Compared to the uncorrected measurement, the maximum sensitivity variation was reduced significantly from 25 dB to 6 dB, revealing the transducer’s intrinsic consistency despite the different geometric features of each element. Due to its distinct geometry compared to the ring-shaped elements, the central element cannot be corrected or evaluated using this method. These results suggest that the proposed algorithm enables the more accurate evaluation of sensitivity consistency for annular phased array transducers, thereby improving measurement reliability in practical applications. Full article
(This article belongs to the Collection Ultrasound Transducers)
Show Figures

Figure 1

23 pages, 14657 KB  
Article
An Annular CMUT Array and Acquisition Strategy for Continuous Monitoring
by María José Almario Escorcia, Amir Gholampour, Rob van Schaijk, Willem-Jan de Wijs, Andre Immink, Vincent Henneken, Richard Lopata and Hans-Martin Schwab
Sensors 2025, 25(21), 6637; https://doi.org/10.3390/s25216637 - 29 Oct 2025
Cited by 1 | Viewed by 1546
Abstract
In many monitoring scenarios, repeated and operator-independent assessments are needed. Wearable ultrasound technology has the potential to continuously provide the vital information traditionally obtained from conventional ultrasound scanners, such as in fetal monitoring for high-risk pregnancies. This work is an engineering study motivated [...] Read more.
In many monitoring scenarios, repeated and operator-independent assessments are needed. Wearable ultrasound technology has the potential to continuously provide the vital information traditionally obtained from conventional ultrasound scanners, such as in fetal monitoring for high-risk pregnancies. This work is an engineering study motivated by that setting. A 144-element annular capacitive micromachined ultrasonic transducer (CMUT) is hereby proposed for 3-D ultrasound imaging. The array is characterized by its compact size and cost-effectiveness, with a geometry and low-voltage operation that make it a candidate for future wearable integration. To enhance the imaging performance, we propose the utilization of a Fermat’s spiral virtual source (VS) pattern for diverging wave transmission and conduct a performance comparison with other VS patterns and standard techniques, such as focused and plane waves. To facilitate this analysis, a simplified and versatile simulation framework, enhanced by GPU acceleration, has been developed. The validation of the simulation framework aligned closely with expected values (0.002 ≤ MAE ≤ 0.089). VSs following a Fermat’s spiral led to a balanced outcome across metrics, outperforming focused wave transmissions for this specific aperture. The proposed transducer presents imaging limitations that could be improved in future developments, but it establishes a foundational framework for the design and fabrication of cost-effective, compact 2-D transducers suitable for 3-D ultrasound imaging, with potential for future integration into wearable devices. Full article
(This article belongs to the Special Issue Wearable Physiological Sensors for Smart Healthcare)
Show Figures

Figure 1

15 pages, 3639 KB  
Article
Research on the Generation of High-Purity Vortex Beams Aided by Genetic Algorithms
by Xinyu Ma, Wenjie Guo, Qing’an Sun, Xuesong Deng, Hang Yu and Lixia Yang
Nanomaterials 2025, 15(18), 1448; https://doi.org/10.3390/nano15181448 - 19 Sep 2025
Cited by 1 | Viewed by 1165
Abstract
Vortex beams (VBs) generated by plasmonic metasurfaces hold great potential in the field of information transmission due to their unique helical phase wavefronts and infinite eigenstates. However, achieving perfect multiplexing and superposition of VBs with different orders remains a challenging issue in nanophotonics [...] Read more.
Vortex beams (VBs) generated by plasmonic metasurfaces hold great potential in the field of information transmission due to their unique helical phase wavefronts and infinite eigenstates. However, achieving perfect multiplexing and superposition of VBs with different orders remains a challenging issue in nanophotonics research. In this paper, based on a single-layer metallic porous metasurface structure applicable to the infrared spectrum, VBs with orders 2, 4, 6, and 8 are realized through the arrangement of annular elliptical apertures. Moreover, perfect VBs are achieved by optimizing key structural parameters using a genetic algorithm. The optimization of key structural parameters via genetic-based optimization algorithms to attain the desired effects can significantly reduce the workload of manual parameter adjustment. In addition, leveraging the orthogonality between VBs of different orders, concentric circular multi-channel VBs array (l = 2, 6) and (l = 4, 8) are realized. High-purity multiplexing architectures (>90%) are achieved via rational optimization of critical structural parameters using a genetic optimization algorithm, which further mitigates information crosstalk in optical communication transmission. The introduction of the genetic algorithm not only reduces the workload of manual arrangement of unit arrays but also enables the generation of more perfect VBs, providing a new research direction for optical communication transmission and optical communication encryption. Full article
(This article belongs to the Special Issue Photonics and Plasmonics of Low-Dimensional Materials)
Show Figures

Figure 1

27 pages, 14921 KB  
Article
Analysis of the Dynamic Process of Tornado Formation on 28 July 2024
by Xin Zhou, Ling Yang, Shuqing Ma, Ruifeng Wang, Zhaoming Li, Yuchen Song, Yongsheng Gao and Jinyan Xu
Remote Sens. 2025, 17(15), 2615; https://doi.org/10.3390/rs17152615 - 28 Jul 2025
Cited by 2 | Viewed by 2506
Abstract
An EF1 tornado struck Nansha District, Guangzhou, Guangdong, on 28 July 2024. To explore the dynamic and thermodynamic changes during the tornado’s life cycle, high-resolution spatiotemporal data from Foshan’s X-band phased-array radar and the direct wind field synthesis algorithm were used to reconstruct [...] Read more.
An EF1 tornado struck Nansha District, Guangzhou, Guangdong, on 28 July 2024. To explore the dynamic and thermodynamic changes during the tornado’s life cycle, high-resolution spatiotemporal data from Foshan’s X-band phased-array radar and the direct wind field synthesis algorithm were used to reconstruct the 3D wind field. The dynamics and 3D structure of the tornado were analysed, with a new parameter, vorticity volume (VV), introduced to study its variation. The observation results indicate that the tornado moved roughly from south to north. During the tornado’s early stage (00:10–00:20 UTC), arc-shaped and annular echoes emerged and positive vorticity increased (peaking at 0.042 s−1). Based on the tornado’s movement direction, the right side of the vortex centre was divergent, while the left side was convergent, whereas the vorticity area and volume continued to grow centrally. During the mature stage (00:23–00:25 UTC), the echo intensity weakened and, at 00:24, the vorticity reached its peak and touched the ground, with the vorticity area and volume also reaching their peaks at the same time. During the dissipation stage (00:25–00:30 UTC), the vorticity and echo features faded and the vorticity area and volume also declined rapidly. The analysis showed that the vorticity volume effectively reflects the tornado’s life cycle, enhancing the understanding of the dynamic and thermodynamic processes during the tornado’s development. Full article
Show Figures

Figure 1

13 pages, 7359 KB  
Article
Tabletop 3D Display with Large Radial Viewing Angle Based on Panoramic Annular Lens Array
by Min-Yang He, Cheng-Bo Zhao, Xue-Rui Wen, Yi-Jian Liu, Qiong-Hua Wang and Yan Xing
Photonics 2025, 12(5), 515; https://doi.org/10.3390/photonics12050515 - 21 May 2025
Cited by 1 | Viewed by 1511
Abstract
Tabletop 3D display is an emerging display form that enables multiple users to share viewing around a central tabletop, making it promising for the application of collaborative work. However, achieving an ideal ring-shaped viewing zone with a large radial viewing angle remains a [...] Read more.
Tabletop 3D display is an emerging display form that enables multiple users to share viewing around a central tabletop, making it promising for the application of collaborative work. However, achieving an ideal ring-shaped viewing zone with a large radial viewing angle remains a challenge for most current tabletop 3D displays. This paper presents a tabletop 3D display based on a panoramic annular lens array to realize a large radial viewing angle. Each panoramic annular lens in the array is designed with a block-structured panoramic front unit and a relay lens system, enabling the formation of a ring-shaped viewing zone and increasing the radial angle of the outgoing light. Additionally, the diffusion characteristics of the optical diffusing screen component are analyzed under large angles of incidence after light passes through the panoramic annular lens array. Then, a method for generating the corresponding elemental image array is presented. The results of the simulation experiments demonstrate that the viewing range is improved to −78.4–−42.2° and 42.6–78.9°, resulting in a total radial viewing angle of up to 72.5°, and the proposed 3D display can present a 360° viewable 3D image with correct perspective and parallax. Full article
(This article belongs to the Special Issue Research on Optical Materials and Components for 3D Displays)
Show Figures

Figure 1

21 pages, 6597 KB  
Article
Effects of Fiber Arrangement on Flow Characteristics Along a Four-Fiber Element of Fiber Extractors
by Oluwaseyi O. Ayeni, Holly A. Stretz and Ahmad Vasel-Be-Hagh
Micromachines 2025, 16(4), 425; https://doi.org/10.3390/mi16040425 - 1 Apr 2025
Cited by 1 | Viewed by 1194
Abstract
Fiber extractors, as process-intensified equipment, facilitate many applications, such as the purification of oils. The development of high-fidelity computational models is crucial to optimize the design. However, simulating microscale flows around tens of thousands of microfiber arrays is computationally unfeasible. Thus, it is [...] Read more.
Fiber extractors, as process-intensified equipment, facilitate many applications, such as the purification of oils. The development of high-fidelity computational models is crucial to optimize the design. However, simulating microscale flows around tens of thousands of microfiber arrays is computationally unfeasible. Thus, it is necessary to identify smaller elements, consisting of only a few fibers, that can represent flow within massively arrayed fiber extractors. This study employed computational fluid dynamics to investigate different configurations of four-fiber elements to achieve this aim. Following previous modeling featuring flow around only one fiber, the goal was to understand how variations in inter-fiber distances affect the phase structures of a corn oil/water mixture, the steady-state interfacial surface area per unit of fluid volume, and the pressure drop along the flow direction. The study explored various total and relative flow rates and contact angles. The research characterized the flow as semi-restricted annular, noting the influence of neighboring fibers on phase complexity. The inter-fiber distance played a crucial role in generating high interfacial areas and reducing pressure. The chaotic nature of the slug interfaces facilitated intermixing between flows along different fibers. Interestingly, the specific interfacial area reached an optimum when the inter-fiber distance was between 10 and 50 μm. Full article
(This article belongs to the Special Issue Application of Microfluidic Technology in Bioengineering)
Show Figures

Figure 1

15 pages, 7264 KB  
Article
High-Frequency 64-Element Ring-Annular Array Transducer: Development and Preclinical Validation for Intravascular Ultrasound Imaging
by Xi Liu, Yuanlong Li, Haiguo Qin and Chang Peng
Biosensors 2025, 15(3), 169; https://doi.org/10.3390/bios15030169 - 5 Mar 2025
Cited by 3 | Viewed by 4746
Abstract
Intravascular ultrasound (IVUS) imaging has become an essential method for diagnosing coronary artery disease. However, traditional mechanically rotational IVUS catheters encounter issues such as mechanical wear and imaging distortions in curved vessels. The ring-annular IVUS array has gained attention because it offers superior [...] Read more.
Intravascular ultrasound (IVUS) imaging has become an essential method for diagnosing coronary artery disease. However, traditional mechanically rotational IVUS catheters encounter issues such as mechanical wear and imaging distortions in curved vessels. The ring-annular IVUS array has gained attention because it offers superior imaging performance without the need for mechanical rotational parts, thereby avoiding rotational imaging distortion. An optimized mechanical micromachining process employing precision dicing technology is proposed in this study, with the objective of achieving higher operating frequencies and minimized outer diameters for a 64-element ring-annular array. This method broadens the range of fabrication options and improves the imaging sensitivity of ring-annular IVUS arrays, as well as eliminating imaging distortion in rotational IVUS catheters, particularly in curved vessels. The probe has a 7.5 Fr (2.5 mm) outer diameter, with key fabrication steps including precision dicing, flexible circuit integration, and Parylene C encapsulation. The ring-annular array has a center frequency of 21.51 MHz with 67.87% bandwidth, with a 56 µm axial resolution and a 276 µm lateral resolution. The imaging performance is further validated by in vitro phantom imaging and ex vivo imaging. Full article
(This article belongs to the Special Issue Biosensors for Biomedical Diagnostics)
Show Figures

Figure 1

16 pages, 8284 KB  
Article
Development and Performance Comparison of a 64-Channel Annular Array Probe Excited Simultaneously by Shorted Symmetrically Positioned Elements
by Shintaro Fukumoto and Takahiro Arakawa
Sensors 2025, 25(4), 1221; https://doi.org/10.3390/s25041221 - 17 Feb 2025
Cited by 1 | Viewed by 1323
Abstract
Ultrasonic testing technology is used to inspect pipe welds in nuclear and thermal power plants. This paper proposes a new method to measure weld defects in thick-walled pipes of about 100 mm using ultrasonic phased array technology. The effectiveness of annular arrays is [...] Read more.
Ultrasonic testing technology is used to inspect pipe welds in nuclear and thermal power plants. This paper proposes a new method to measure weld defects in thick-walled pipes of about 100 mm using ultrasonic phased array technology. The effectiveness of annular arrays is confirmed by numerical simulations, and element arrangements that enable point focusing and sector scanning are considered. The energy concentration of annular arrays is 7% higher than that of linear arrays and 3% higher than that of matrix arrays. Similarly, the sound pressure ratio of grating lobes is equivalent to that of linear arrays and 20% lower than that of matrix arrays. This array probe is driven by 64 channels by dividing the ring of an 8-element annular array probe in parallel and shorting the elements at symmetrical positions. The effectiveness is examined by measuring specimens with flat-bottom holes and simulated spherical defects. The authors confirmed peaks in the echo intensity of a φ1 mm flat-bottom hole and a φ3 mm pseudo-spherical defect arranged at 5 mm intervals. Comparing the measured results with a conventional linear array transducer, the results from the proposed method show that the number and size of defects can be accurately measured. Full article
(This article belongs to the Section Physical Sensors)
Show Figures

Figure 1

25 pages, 10678 KB  
Article
Heat Transfer in Annular Channels with the Inner Rotating Cylinder and the Radial Array of Cylinders
by Aidar Hayrullin, Alex Sinyavin, Aigul Haibullina, Margarita Khusnutdinova, Veronika Bronskaya, Dmitry Bashkirov, Ilnur Gilmutdinov and Tatyana Ignashina
Energies 2024, 17(23), 6047; https://doi.org/10.3390/en17236047 - 1 Dec 2024
Cited by 3 | Viewed by 3181
Abstract
Numerical investigations of heat transfer for forced, mixed, and natural convection conditions within an annular channel are carried out. The main objective was to investigate, for the first time, the effect of the radial cylinder array on heat transfer in the annular channel [...] Read more.
Numerical investigations of heat transfer for forced, mixed, and natural convection conditions within an annular channel are carried out. The main objective was to investigate, for the first time, the effect of the radial cylinder array on heat transfer in the annular channel with the rotating cylinder. The governing equations for velocity and temperature with the Boussinesq approximation were solved using the finite-volume method. The heat transfer quantities were obtained for different Rayleigh numbers (104–106), the radius ratios (1.4–2.6), the radial cylinder spacing, and for different rotating velocities in the form of the Richardson number (10−2–104). The Prandtl number was 0.7. It has been shown that radial cylinders do not influence significantly the intensity and the local distribution of heat transfer on the inner rotating cylinder. The Nusselt number was 1.4–2.0 times higher on the radial cylinder array for all convection modes relative to the outer flat surface. For all annuli gaps with radial cylinders, the maximal values of the Nusselt number were observed with an increase of the radial spacing of cylinders. Full article
(This article belongs to the Special Issue Numerical Heat Transfer and Fluid Flow 2024)
Show Figures

Figure 1

18 pages, 7815 KB  
Article
Feasibility of Backscattering Coefficient Evaluation of Soft Tissue Using High-Frequency Annular Array Probe
by Jungtaek Choi, Jeffrey A. Ketterling, Jonathan Mamou, Cameron Hoerig, Shinnosuke Hirata, Kenji Yoshida and Tadashi Yamaguchi
Sensors 2024, 24(22), 7118; https://doi.org/10.3390/s24227118 - 5 Nov 2024
Viewed by 2554
Abstract
The objective of this work is to address the need for versatile and effective tissue characterization in abdominal ultrasound diagnosis using a simpler system. We evaluated the backscattering coefficient (BSC) of several tissue-mimicking phantoms utilizing three different ultrasonic probes: a single-element transducer, a [...] Read more.
The objective of this work is to address the need for versatile and effective tissue characterization in abdominal ultrasound diagnosis using a simpler system. We evaluated the backscattering coefficient (BSC) of several tissue-mimicking phantoms utilizing three different ultrasonic probes: a single-element transducer, a linear array probe for clinical use, and a laboratory-made annular array probe. The single-element transducer, commonly used in developing fundamental BSC evaluation methods, served as a benchmark. The linear array probe provided a clinical comparison, while the annular array probe was tested for its potential in high-frequency and high-resolution ultrasonic observations. Our findings demonstrate that the annular array probe meets clinical demands by providing accurate BSC measurements, showcasing its capability for high-frequency and high-resolution imaging with a simpler, more versatile system. Full article
(This article belongs to the Special Issue Biomedical Imaging, Sensing and Signal Processing)
Show Figures

Figure 1

10 pages, 7497 KB  
Communication
Dual-Band Antenna with Pattern and Polarization Diversity
by Jungmin Mo and Youngje Sung
Sensors 2024, 24(15), 5008; https://doi.org/10.3390/s24155008 - 2 Aug 2024
Cited by 2 | Viewed by 2315
Abstract
This study proposes a pattern–diversity antenna with different radiation patterns at two different frequency bands (f1 and f2; f1: broadside radiation pattern, f2: conical radiation pattern). The proposed structure consists of a central circular antenna [...] Read more.
This study proposes a pattern–diversity antenna with different radiation patterns at two different frequency bands (f1 and f2; f1: broadside radiation pattern, f2: conical radiation pattern). The proposed structure consists of a central circular antenna and two annular ring antennas, with each of the antennas having individual ports. Two of the ports (port 1 and port 3) exhibit orthogonal broadside radiation patterns at low bands, and the other two ports (port 1 and port 2) exhibit orthogonal conical radiation patterns at high bands. Thus, they have polarization diversity characteristics. To improve isolation between the ports, the inner part of the annular ring antennas is shorted by an array, and the outermost port is positioned orthogonal to the other ports. Using this configuration, the isolation values between the ports are −26.7 and −30.1 dB at the two frequency bands, respectively. Using the fabricated prototype, experimental results show that the proposed antenna achieves −10 dB bandwidths of 240 MHz (5.71–5.95 GHz) and 210 MHz (7.69–7.9 GHz) at f1 and f2, respectively. Full article
(This article belongs to the Section Electronic Sensors)
Show Figures

Figure 1

Back to TopTop